# Conditions INSRPT
<span hidden data-pagefind-meta={"title:Conditions INSRPT — application handbook (FV 202604)"} />

EDIFACT message type **INSRPT** · format version **202604** · 31 conditions · 4 packages · 0 UB conditions · from 8 handbook file(s)

## Conditions

<div className="maco-tabellenrahmen">

| Marker | Condition |
|---|---|
| **[1]** | If the message sender has been informed by the customer. |
| **[2]** | If SG7 STS+Z06+Z10+ZC1 is present. |
| **[3]** | If present. |
| **[4]** | If MP-ID in SG2 NAD+MR in the role NB |
| **[5]** | If MP-ID in SG2 NAD+MR in the role LF |
| **[6]** | If no fault could be determined. |
| **[7]** | If no further SG7 with the same reporting point and DTM+9 is present |
| **[8]** | If STS+Z06+Z10 is present in this SG7 |
| **[9]** | If a fault was identified that the MSB could not rectify independently and through no fault of its own. |
| **[10]** | If in this STS DE4405 = Z09 |
| **[11]** | If in this STS DE4405 = Z10 |
| **[12]** | If a fault was identified that was rectified by the MSB. |
| **[13]** | If DE2379 = 303 |
| **[14]** | Only MP-ID from the electricity division |
| **[494]** | The date stated here must be the point in time at which the document was created, or a point in time before that |
| **[495]** | The point in time must be ≤ the value in DE2380 of DTM+137 |
| **[500]** | Note: Transaction number (DOC DE1004) from process step 4b „Confirmation of the fault report“ (gas) or process step 2 „Response“ (electricity). |
| **[506]** | Note: To be used if the fault cannot be rectified by the MSB independently and through no fault of its own. |
| **[507]** | Note: SG7 FTX+AAO must state the overarching cause due to which the MSB is unable to rectify the fault. |
| **[508]** | Note: Transaction number from DOC DE1004. |
| **[509]** | Note: Use of the ID of the metering location |
| **[510]** | Note: Use of the ID of the market location |
| **[511]** | Note: The numbering starts at 1 in every document |
| **[512]** | Note: If a fault was detected and rectified by the MSB, the segment group must be stated twice with the same reporting point |
| **[513]** | Note: If no fault was detected, the segment group must be stated exactly once |
| **[514]** | Note: If a fault was detected that could not be rectified by the MSB, the segment group must be stated exactly once |
| **[515]** | Note: "≤ the value in DE2380 of DTM+137" means that the day stated there must be ≥ the day stated in this DTM if code 102 is entered in DE2379. |
| **[908]** | Format: possible values: 1 to n |
| **[931]** | Format: ZZZ = +00 |
| **[950]** | Format: market location ID |
| **[951]** | Format: Metering point identifier |

</div>

## Condition packages

Condition packages bundle prerequisites.

<div className="maco-tabellenrahmen">

| Package | Prerequisites | Conditions |
|---|---|---|
| **[1P]** | -- | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
| **[2P]** | [6] | If no fault could be determined . |
| **[3P]** | [12] | If a fault was identified that was rectified by the MSB . |
| **[4P]** | [9] | If a fault was identified that the MSB could not rectify independently and through no fault of its own . |

</div>

<Hinweisbereich>

This page carries the free text of every condition that the application handbook of message type **INSRPT** references in this format version. A row of the handbook writes `Muss [704]`; what [704] requires is here.

The list applies **to the message type**, not to a single check identifier. This is not a simplification but the form of the source: the condition list is present identically in every handbook file of the format.

:::caution{title="Why no assignment to individual check identifiers is given here"}

The intermediate format from which this documentation reads the handbook rows assigns conditions to a **column** — and this assignment is shifted against the original. Measured on 05.09.2026 against UTILMD electricity: the handbook lists `STS DE9013` as `X [360]` (approval codes only) for check identifier **55017** and `X [359]` (rejection codes only) for **55018**; the intermediate format puts `[360]` on 55016 and `[359]` on 55017 **and** 55018. The same applies to `FTX Muss [83]`: at 55018 in the handbook, at 55017 in the intermediate format.

Independently confirmed by the change lists of the source: change IDs 25242, 25821, 25822, 25445 and 25243 explicitly locate [83], [351] and [352] in „Use case 55018 Rejection of contract termination“. No entry assigns them to 55016 or 55017.

That is why the **text** of every condition is given here and nowhere the claim as to which condition applies to which check identifier. Anyone who needs that looks it up in the original application handbook.

:::

As measured on 05.09.2026, **no** `ahb_expression` in this source points to a package marker — the condition packages are listed on this page because the source carries them, not because a handbook line refers to them.

</Hinweisbereich>