# Conditions ORDERS
<span hidden data-pagefind-meta={"title:Conditions ORDERS — application handbook (FV 202604)"} />

EDIFACT message type **ORDERS** · format version **202604** · 248 conditions · 12 packages · 3 UB conditions · from 46 handbook file(s)

## Conditions

<div className="maco-tabellenrahmen">

| Marker | Condition |
|---|---|
| **[1]** | If IMD+Z03 present |
| **[2]** | If BGM+7 present |
| **[6]** | If MP-ID in SG2 NAD+MS with role LF is present |
| **[7]** | If MP-ID in SG2 NAD+MS with role NB is present |
| **[9]** | If known |
| **[12]** | If present |
| **[13]** | If SG2 LOC+172 is not present |
| **[15]** | If MP-ID in SG2 NAD+MS with role MSB is present |
| **[16]** | If a subordinate SG is present |
| **[17]** | If a segment is present within the SG |
| **[18]** | If IMD++Z11 present |
| **[19]** | If IMD++Z12 present |
| **[21]** | If BGM+Z28 present |
| **[23]** | If MP-ID in SG2 NAD+MR with role NB is present |
| **[24]** | If IMD++Z35 present |
| **[26]** | If MP-ID in SG2 NAD+MS with role ÜNB is present |
| **[27]** | If MP-ID in SG2 NAD+MR with role MSB is present |
| **[28]** | If MP-ID in SG2 NAD+MR from division Electricity |
| **[29]** | If MP-ID in SG2 NAD+MR from division Gas |
| **[33]** | If IMD+Z01 present |
| **[34]** | If IMD+Z02 present |
| **[35]** | IMD++Z14+Z06 present |
| **[36]** | If MP-ID in SG2 NAD+MR with role NB is not present |
| **[38]** | If FTX+Z04/Z05 present |
| **[45]** | If MP-ID in SG2 NAD+MS with role MSB is not present |
| **[46]** | If SG29 IMD++Z46 is present |
| **[47]** | If SG29 IMD++Z46 is not present |
| **[51]** | If BGM+Z48 present |
| **[54]** | If FTX+Z06 present |
| **[55]** | If DTM+469 (start at the earliest possible date) not present |
| **[56]** | If DTM+203 (execution date) not present |
| **[57]** | If NAD DE3124 is not present in the same SG2 |
| **[60]** | MP-ID only from division gas |
| **[61]** | MP-ID only from division electricity |
| **[62]** | MP-ID with role MSB |
| **[63]** | MP-ID with role NB |
| **[64]** | If SG2 NAD+Z03 is not present |
| **[65]** | If FTX+Z08 present |
| **[67]** | If DTM+163 not present |
| **[68]** | If DTM+7 not present |
| **[69]** | If NAD+Z23 not present |
| **[70]** | If NAD+Z03 not present |
| **[75]** | If no metering time period is required for the required value |
| **[76]** | If in the same SG29 with Z54 in LIN DE1229 (required product of the market location) the PIA+5 DE7140 is present with a metering product from the code list of configurations, chapter 2.1.1 "Standard metering product of the market location with the option of assigning a metering time period" |
| **[77]** | If code Z39 (code of the metering time period definition) is present in DE7059 in the same CCI |
| **[78]** | If in the same SG29 with Z55 in LIN DE1229 (required product of the grid location) the PIA+5 DE7140 is present with a metering product from the code list of configurations, chapter 2 "Code list of the standard metering product electricity for values of type 1" with the value property "reactive energy". |
| **[79]** | If another SG29 with Z54 in LIN DE1229 (required product of the market location) with PIA+5+9991000000078:Z11 (for active energy load curve 1/4-hourly) is present |
| **[80]** | If no other SG29 with Z54 in LIN DE1229 (Required product of the market location) with PIA+5+9991000000078:Z11 (active energy load curve 1/4-hourly) is present |
| **[81]** | If in the same SG29 with Z54 in LIN DE1229 (required product of the market location), the PIA+5+9991000000078:Z11 (active energy load curve 1/4-hourly) is present |
| **[82]** | If another SG29 with Z54 in LIN DE1229 (required product of the market location) with PIA+5 DE7140 with a metering product from the code list of configurations, chapter 2.1.1 „Standard metering product of the market location with the option of assigning a metering time period“ is present |
| **[83]** | If no other SG29 with Z54 in LIN DE1229 (Required product of the market location) with PIA+5 DE7140 with a metering product from the code list of configurations, chapter 2.1.1 „Standard metering product of the market location with the option of assigning a metering time period“ is present |
| **[84]** | IMD++Z14+Z07 present |
| **[85]** | If in the same SG29 with Z54 in LIN DE1229 (required product of the market location), the PIA+5+9991000000086:Z11 (active energy highest 1/4 hour in the month) is present |
| **[86]** | If in the same SG29 with Z19 in LIN DE1229 (required product of the metering location) the PIA+5 DE7140 is present with a metering product from the code list of configurations chapter 2.3.1 "Standard metering product of the metering location with the option of assigning a metering time period" |
| **[87]** | If FTX+Z09/Z10 present |
| **[91]** | If in this data element no other package in this SG30 in the same SG29 LIN leads to the possibility of specifying at least one other code. |
| **[93]** | If a SG29 with Z16 in LIN DE1229 (required product of the tranche) is not present in the same message |
| **[94]** | If a SG29 with Z54 in LIN DE1229 (required product of the market location) is not present in the same message |
| **[95]** | Metering product code from chapter 2.1 "Standard metering products of the market location" of the code list of configurations |
| **[96]** | Metering product code from chapter 2.2 "Standard metering products of the tranche" of the code list of configurations |
| **[97]** | If FTX+Z10 present |
| **[99]** | If FTX+Z08/Z10 present |
| **[100]** | Metering product code from chapter 2.3 "Standard metering products of the metering location" of the code list of configurations |
| **[101]** | If MP-ID in SG2 NAD+MR with role MSB is not present in the division Gas |
| **[102]** | If in the same SG29 LIN the CCI+++Z25 (device type transformer) is present |
| **[103]** | If in the same SG29 LIN the CCI+++Z25 (device type transformer) is not present |
| **[104]** | If MP-ID in SG2 NAD+VY with role LF is present |
| **[105]** | If the previous configuration with metering times of the LF is to be terminated by the LF |
| **[106]** | if IMD++Z60 (order cancellation of metering product with metering time period definition of the LF) is not present |
| **[107]** | If IMD++Z57 (order cancellation of metering time period definition) not present |
| **[108]** | If RFF+AGK (configuration ID) not present |
| **[109]** | If LOC+172 (reporting point) not present |
| **[110]** | if DTM+163 (start of time period for value request) is present |
| **[112]** | If in the same SG29 LIN++Z54 (required product of the market location), the PIA+5+9991000000078: Z11 (active energy load curve 1/4-hourly) is present |
| **[113]** | If LIN DE1229 with code Z42 (metering time period definition) is present |
| **[114]** | If LIN DE1229 with code Z69 (switching time definition) is present |
| **[115]** | If LIN DE1229 with code Z70 (power curve definition) is present |
| **[117]** | If SG29 LIN++Z64 (Required product switching time definitions) is present |
| **[118]** | If SG29 LIN++Z65 (Required product power curve definitions) is present |
| **[119]** | If SG29 LIN++Z66 (Required product ad hoc control channel) is present |
| **[120]** | If SG29 LIN++Z67 (Required metering product for values of type 2 from backend) is present |
| **[121]** | If SG29 LIN++Z68 (Required product configuration permission for values of type 2 from SMGW) is present |
| **[122]** | If SG1 RFF+Z41 (reference number of the registration transaction pursuant to WiM) not present |
| **[123]** | If DTM+203 (execution date) not present |
| **[124]** | If SG1 RFF+Z41 (reference number of the registration transaction pursuant to WiM) present |
| **[125]** | Only the configuration products are permitted that are contained in chapter 4.1 „Configuration products switching time definition“ of the code list of configurations. |
| **[126]** | Only the configuration products are permitted that are contained in chapter 4.2 „Configuration products power curve definition“ of the code list of configurations. |
| **[127]** | Only the configuration products are permitted that are contained in chapter 4.3 „Configuration products ad-hoc control channel“ of the code list of configurations. |
| **[128]** | Only the metering products are permitted that are contained in chapter 4.5 „Metering products for values according to type 2 from the backend for LF and NB“ of the code list of configurations. |
| **[129]** | Only the metering products are permitted that are contained in chapter 4.4 „Metering products with configuration permission for values according to type 2 from SMGW“ of the code list of configurations. |
| **[130]** | If the ID of a market location is specified in LOC+172 DE3225 (reporting point) |
| **[131]** | If the ID of a metering location is specified in LOC+172 DE3225 (reporting point) |
| **[132]** | If the ID of a grid location is specified in LOC+172 DE3225 (reporting point) |
| **[133]** | If the ID of a controllable resource is specified in LOC+172 DE3225 (reporting point) |
| **[134]** | If the item was present in the original response to the order placement from SG1 RFF+Z42 and is to be disputed |
| **[135]** | If SG29 LIN++Z64 (Required product switching time definitions) is not present |
| **[136]** | If SG29 LIN++Z65 (Required product power curve definitions) is not present |
| **[137]** | If SG29 LIN++Z66 (Required product ad hoc control channel) is not present |
| **[138]** | If SG29 LIN++Z67 (Required metering product for values of type 2 from backend) is not present |
| **[139]** | If SG29 LIN++Z68 (Required product configuration permission for values of type 2 from SMGW) is not present |
| **[140]** | Metering product code from chapter 2.4 "Standard metering products of the grid location" of the code list of configurations |
| **[141]** | Only the metering product position codes are permitted that are contained in chapter 4.7 „Type of values for metering products according to type 2“ of the code list of configurations. |
| **[142]** | If within the same SG29 LIN a product is specified in PIA+5 DE7140 (Required product configuration permission for values of type 2 from SMGW) that is marked in the code list of configurations in chapter 4.4 „Metering products with configuration permission for values of type 2 from SMGW“ in the column "Trigger" with the value "When falling below / exceeding the threshold value". |
| **[143]** | If the ID of a controllable resource is specified in LOC+172 DE3225 (reporting point) |
| **[147]** | if the code EM is present in DE3155 in the same COM |
| **[148]** | if the code TE / FX / AJ / AL is present in DE3155 in the same COM |
| **[152]** | If in SG29 LIN (required product of the metering location) the PIA+5 DE7140 is present with a product code that is present in the code list of configurations in chapter 7 "Products for the order placement of a change at a location" in the "column designation" with the value "further energy flow direction". |
| **[153]** | Only the product codes are permitted that are present with the value "Metering location" in the column "Level" in chapter 7 "Products for the order placement of a change at a location" of the code list of configurations. |
| **[154]** | Only the product codes are permitted that are present with the value "Grid location" in the column "Level" in chapter 7 "Products for the order placement of a change at a location" of the code list of configurations. |
| **[155]** | Only the product codes are permitted that are present with the value "Controllable resource" in the column "Level" in chapter 7 "Products for the order placement of a change at a location" of the code list of configurations. |
| **[156]** | Furthermore, only the product codes are permitted that are marked with an "X" in the column "NB" within the column "Product orderable from MSB by market role" in chapter 7 "Products for the order placement of a change at a location" of the code list of configurations. |
| **[157]** | Furthermore, only the product codes are permitted that are marked with an "X" in the column "LF" within the column "Product orderable from MSB by market role" in chapter 7 "Products for the order placement of a change at a location" of the code list of configurations. |
| **[158]** | Only the product codes are permitted that are listed in chapter 6.2 "Products for the order placement of a change to billing data" of the code list of configurations. |
| **[159]** | If in the same SG29 LIN a product code is named in the PIA+5 (required product billing data) DE7140 that is filled with a code in the column "Code of the product property (value range)" in the code list of configurations in chapter 6.2 "Products for the order placement of a change of billing data". |
| **[160]** | Only the product property codes for the product code stated in the same SG29 LIN in PIA+5 (Required product billing data) DE7140 are permitted that appear in the same row as the product code in chapter 6.2 "Products for the order placement of a change to billing data" of the code list of configurations and are listed in the column "Product property code (value range)". |
| **[161]** | If in the same SG29 LIN (required product billing data) the SG30 CAV+ZH9 (code of the product property) is not present. |
| **[162]** | Only the value range is permitted that belongs to the product stated in the same SG29 LIN in PIA+5 (required product billing data) DE7140 and that is stated in the code list of configurations in chapter 6.2 "Products for ordering a change of billing data" in the same row as the product code in the column "Value details for line item". |
| **[163]** | If a SG30 CCI+++ZA9 (metering product relevant for transmission system operator (TSO)) is present within the message. |
| **[164]** | If the configuration of the tranche named in SG34 RFF+Z20 DE1154 (reference to the ID of the tranche) remains unchanged within the same SG29 LIN++Z16 (required product of the tranche). |
| **[165]** | If the configuration of the tranche named in SG34 RFF+Z20 DE1154 (reference to the ID of the tranche) is to be reconfigured within the same SG29 LIN++Z16 (required product of the tranche) due to an assignment of a LF, or the tranche has been newly formed. |
| **[166]** | If this concerns the setup of the configurations due to an assignment of a LF to a tranche |
| **[167]** | If SG2 NAD+DP (reporting point), SG3 RFF+Z20 (reference to ID of the tranche) present |
| **[168]** | If SG2 NAD+DP (reporting point), SG3 RFF+Z20 (reference to ID of the tranche) not present |
| **[169]** | If in SG29 LIN++Z19 (required product of the metering location) in SG30 CCI (assigned metering time period definition in DE7059 the code Z39 (code of the metering time period definition) is present |
| **[170]** | If in the same SG29 LIN the SG30 CCI+Z37++ZD1 (basis for forming the tranche size) (percentage) is present |
| **[171]** | If in the same SG29 LIN (required product of the tranche) the IMD+++Z64 (service description configuration) (new configuration) is present |
| **[172]** | If the location named in SG2 LOC+172 DE3225 concerns the integration into a customer installation or the removal from a customer installation pursuant to §20 Abs.1d EnWG. For details see UTILMD AHB electricity. |
| **[173]** | If IMD++Z66 (termination of configuration due to transfer of the market location to a dormant market location) present |
| **[174]** | If IMD++Z67 (activation of configuration in the currently dormant market location) present |
| **[175]** | If SG2 NAD+DP (reporting point), SG3 RFF+Z59 (reference to the ID of the market location of the customer installation) present |
| **[176]** | If SG2 NAD+DP (reporting point), SG3 RFF+Z59 (reference to the ID of the market location of the customer installation) not present |
| **[177]** | If IMD++Z66 (termination of configuration due to transfer of the market location to a dormant market location) not present |
| **[178]** | If a declaration of assignment from the customer is requested by the NB. |
| **[179]** | If in the same SG29 LIN the product "Recipient of the remuneration for feed-in" from the code list of configurations in chapter 6.2 "Products for the order placement of a change of billing data" is named in the PIA+5 (required product billing data) DE7140 and in the same SG29 LIN in the SG30 CAV+ZH9 (code of the product property) DE7110 is filled with the code "supplier" from the column "Code of the product property (value range)". |
| **[180]** | If in the same SG29 LIN a product code is named in the PIA+5 (required product billing data) DE7140 for which the condition possibly contained in the column "value details for item" in the code list of configurations in chapter 6.2 "Products for the order placement of a change of billing data" is met. |
| **[181]** | If BGM+Z93 (order placement for an offer for change of the technology of the location) present |
| **[182]** | If BGM+Z12 (change of the technology of the location) present. |
| **[183]** | If MP-ID in NAD+MS from the Gas division |
| **[490]** | if the value in this DE, at position CCYYMMDDHHMM, is a point in time within the period stated in the table in chapter 3.5 “Overview of German statutory summer time (MESZ)” in the columns: “Summer time (MESZ) from” representation in UTC and “Summer time (MESZ) to” representation in UTC. |
| **[491]** | if the value in this DE, at position CCYYMMDDHHMM, is a point in time within the period stated in the table in chapter 3.6 “Overview of German statutory time (MEZ)” in the columns: “Winter time (MEZ) from” representation in UTC and “Winter time (MEZ) to” representation in UTC. |
| **[492]** | if MP-ID in NAD+MR from division electricity |
| **[493]** | if MP-ID in NAD+MR from division gas |
| **[494]** | The date stated here must be the point in time at which the document was created, or a point in time before that. |
| **[495]** | The point in time must be ≤ the value in DE2380 of DTM+137 |
| **[500]** | Note: Metering point of the BAS |
| **[501]** | Note: Metering point of the DZR |
| **[503]** | Note: Indication of a technical contact person for the device takeover |
| **[506]** | Note: Date up to which the MSBA is obliged to continue |
| **[514]** | Note: The subscription can be started at the grid operator at the earliest from the current delivery month. |
| **[515]** | Note: For subscription start and subscription end respectively, the specified observation time interval determines from when or until when (inclusive) the subscription is to run. |
| **[517]** | Note: Metering point of the LF-AASZR |
| **[518]** | Note: For subscription start and subscription end respectively, the specified execution date determines from when or until when (inclusive) the subscription is to run. |
| **[519]** | Note: For gas, the request always refers both to the preliminary profile values and to the final profile values, if these are already available. |
| **[521]** | Note: Use of the ID of the market location |
| **[522]** | Note: Use of the ID of the metering location |
| **[523]** | Note: Use of the ID of the tranche |
| **[525]** | Note: Value from BGM DE1004 of the MSCONS |
| **[527]** | Note: Metering point of the BG-SZR (category B) |
| **[530]** | Note: Value from BGM+310 DE1004 of the QUOTES with which the quotation was made. |
| **[531]** | Note: Value from LIN DE1082 of the QUOTES with which the quotation was made |
| **[532]** | Note: Value from BGM+Z29 DE1004 of the QUOTES with which the quotation for the billing of the metering point operation was made. |
| **[533]** | Note: Bailiff has specified the appointment |
| **[535]** | Note: Use of the ID of the metering location of the electricity division |
| **[536]** | Note: Transaction number from IDE DE7402 of the UTILTS with BGM+Z59 |
| **[539]** | Note: Only codes of metering time periods from the list of the NB must be specified |
| **[540]** | Note: Only codes of metering time periods from the list of the LF must be specified |
| **[542]** | Note: Value from BGM+Z57 DE1004 of the QUOTES with which the quotation was made. |
| **[543]** | Note: Value from BGM+Z57 DE1004 of the ORDERS with which the order placement for the values was made. |
| **[545]** | Note: Only the metering products of the metering locations that are required for the market location named in the SG2 or for its tranches are specified. Metering products at the metering location for further market locations remain unchanged. |
| **[547]** | Note: Document number from BGM+Z60 DE1004 of the UTILTS |
| **[548]** | Note: If the change of the device configuration is transmitted with a metering time period, enter here the MP-ID of the owner of the metering time period list. If no metering time period is to be used any longer instead of the previous metering time period, enter here the MP-ID of the owner of the metering time period list from which the metering time period was used previously. |
| **[549]** | Note: Always applies to the complaint about meter readings. The only exception is a complaint about a missing meter reading due to a periodic meter reading for which the MSB had transmitted the information on the "planned periodic meter reading of the MSB (electricity)" at the object of the market location in the UTILMD in SG6 DTM+752 as the reading period (DE2379 with code 104 MMWW-MMWW) in the previous master data, because in that case no point in time can be specified and the time interval in the segment form DTM+163 / DTM+164 must be used. |
| **[550]** | Note: Applies only if it is a complaint about a missing meter reading due to a periodic meter reading for which the MSB had transmitted the information on the "planned periodic meter reading of the MSB (electricity)" at the object of the market location in the UTILMD in SG6 DTM+752 as the reading period (DE2379 with code 104 MMWW-MMWW) in the previous master data. |
| **[551]** | Note: The SG29 is to be repeated as often as necessary for all metering products and metering times to be named that must be configured at the metering location by the MSB from the point in time named in DTM+203. Metering products not named are no longer contained in the configuration from that point in time onwards. |
| **[552]** | Note: Use of the ID of the grid location |
| **[553]** | Note: Use of the ID of the controllable resource |
| **[554]** | Note: Value from BGM+Z74 DE1004 of the QUOTES with which the quotation was made. |
| **[555]** | Note: Transaction number from SG4 IDE+24 DE7402 of the UTILMD with BGM+E01 with which the registration of the MSB switch was carried out. |
| **[557]** | Note: Only the metering products of the metering locations that are required for the grid location named in the SG2 are specified. Metering products at the metering location for further grid locations or market locations remain unchanged. |
| **[558]** | Note: Document number from BGM+Z78 DE1004 of the UTILTS |
| **[559]** | Note: Document number from BGM+Z79 DE1004 of the UTILTS |
| **[560]** | Note: Transaction number from IDE DE7402 of the UTILTS with BGM+Z80 |
| **[561]** | Note: Transaction number from IDE DE7402 of the UTILTS with BGM+Z81 |
| **[562]** | Note: Value from BGM+Z73 DE1004 of the IFTSTA with which the response to the order placement for the configuration was transmitted |
| **[563]** | Note: Transaction number from CNI DE1490 of the IFTSTA with BGM+Z73 with which the response to the order placement of the configuration was transmitted |
| **[564]** | Note: For receiving the values according to type 2 from the SMGW. |
| **[566]** | Note: Use of the ID of the technical resource |
| **[567]** | Note: Only one piece of information may be transmitted in DE3148 |
| **[568]** | Note: If the set-up of the configuration is transmitted with a metering time period, enter here the MP-ID of the NB as the owner of the metering time period list. |
| **[569]** | Note: MaBiS metering point of the LF-SZR |
| **[570]** | Note: for stating the contact details of the supplier's customer in order to simplify the change to the technology. |
| **[571]** | Note: MSB of the market location to which the values of the further energy flow direction of the metering location are to be transmitted. |
| **[572]** | Note: MSB of the market location of the customer installation into which the affected location is integrated. |
| **[573]** | Note: An URI IPv4 must be specified for the provision of the values. |
| **[574]** | Note: An URI IPv6 must be specified for the provision of the values. |
| **[575]** | Note: If the requested change point in time is a fixed point in time. |
| **[576]** | Note: If the requested change point in time is the next possible date on or after the stated point in time. |
| **[577]** | Note: Value from BGM+Z93 (order placement for a quotation for the change of the technology of the location) DE1004 of the QUOTES with which the quotation was made. |
| **[578]** | Note: Value from BGM DE1004 of the PRICAT with which price sheet B of the MSB on which the quotation is based from the point of view of the NB was transmitted. |
| **[579]** | Note: Statement of the start point in time of the desired implementation date from the ordering party's point of view. |
| **[580]** | Note: Indication of the end point in time of the desired implementation date from the orderer's perspective. |
| **[591]** | Note: If this concerns the order placement of a previous quotation within the scope of the BDEW application guide "Processes for changing the technology at locations". |
| **[592]** | Note: if this concerns the order issuance of a change in accordance with WiM Part 1 UC "Change of metering location". |
| **[903]** | Format: Possible value: 1 |
| **[906]** | Format: max. 3 decimal places |
| **[911]** | Format: Possible values: 1 to n, starting at 1 for each message or segment group and ascending consecutively |
| **[914]** | Format: Possible value: &gt;0 |
| **[922]** | Format: TR-ID |
| **[930]** | Format: max. 2 decimal places |
| **[931]** | Format: ZZZ = +00 |
| **[932]** | Format: HHMM = 2200 |
| **[933]** | Format: HHMM = 2300 |
| **[934]** | Format: HHMM = 0400 |
| **[935]** | Format: HHMM = 0500 |
| **[939]** | Format: the character string must contain the characters @ and . |
| **[940]** | Format: the character string must begin with the character + and may only be followed by digits |
| **[950]** | Format: market location ID |
| **[951]** | Format: Metering point identifier |
| **[955]** | Format: Possible value: &lt;100 |
| **[960]** | Format: Grid location ID |
| **[961]** | Format: SR-ID |
| **[962]** | Format: max. 6 digits before the decimal point |
| **[967]** | Format: Certificate body in accordance with X509.1, BSI TR-03109-4 |
| **[2001]** | The SG29 must be repeated as many times as there are tranches for the market location stated in SG2 from DTM+203 (execution date) onwards. |
| **[2002]** | Must be specified at least twice |
| **[2003]** | The SG29 must be repeated as many times as there are metering locations for the market location stated in SG2 from DTM+203 (execution date) onwards, and for each of these metering locations all metering products must be stated that exist from DTM+203 (execution date) onwards in the market location stated in SG2 or in its tranches. |
| **[2004]** | The SG29 must be repeated as often as required so that all devices of the affected device type that are to be exchanged as part of the device replacement due to a MSB change are stated. |
| **[2005]** | The SG34 RFF+Z09 (device number) must be specified exactly once per SG29 LIN |
| **[2006]** | The SG34 RFF+Z09 (device number) must be specified up to three times per SG29 LIN |
| **[2007]** | The SG29 must be repeated as many times as there are metering locations for the grid location stated in SG2 from DTM+203 (execution date) onwards, and for each of these metering locations all metering products must be stated that exist from DTM+203 (execution date) onwards in the grid location stated in SG2. |
| **[2050]** | The SG29 must be specified exactly once per message |
| **[2060]** | The SG29 LIN+Z64 (required product switching time definitions) must be specified at most once per message |
| **[2061]** | The SG29 LIN++Z65 (required product load curve definitions) must be specified at most once per message |
| **[2062]** | The SG29 LIN++Z66 (required product ad-hoc control channel) must be specified at most once per message |
| **[2063]** | The SG29 LIN++Z67 (required metering product for values according to type 2 from the backend) must be specified at most once per message |
| **[2064]** | The SG29 LIN++Z68 (required product configuration permission for values according to type 2 from SMGW) must be specified at most once per message |
| **[2065]** | This SG30 must be repeated as many times as a product is stated for the different metering product item codes for the product stated in PIA+5 DE7140 (required product configuration permission for values of type 2 from SMGW) within the same SG29 LIN, which is marked in the code list of configurations in chapter 4.4 "Metering products with configuration permission for values of type 2 from SMGW" in the column "trigger" with the value "When falling below / exceeding the threshold value". |
| **[2066]** | The SG3 RFF+Z37 reference to ID of the technical resource must be repeated until all IDs of the technical resources are stated that are to be assigned with this transaction to the controllable resource in LOC+172 DE3225 (reporting point). |
| **[2088]** | The SG29 must be repeated as often as required so that all metering products from DTM+203 (execution date) onwards for the grid location stated in SG2 are stated. |
| **[2089]** | The SG29 must be repeated as often as required so that all metering products from DTM+203 (execution date) onwards for the market location stated in SG2 are stated. |
| **[2090]** | To be given at least once for a 33-digit ID in SG2 LOC+172 (reporting point) DE3225 |
| **[2092]** | The SG29 must be specified at most once per message |
| **[2094]** | Per message, the SG29 LIN (line item data) must be specified as many times as there are line items to be ordered from the quotation that is stated in SG1 RFF+AAG (reference message number), DE1154. |
| **[2095]** | This SG29 must be repeated as often as required so that all products for the location are stated that are requested from DTM+203 (execution date) onwards and whose combination is possible according to the code list of configurations, chapter 7 "Products for ordering a change at a location". |
| **[2096]** | The SG3 reference to the ID of the tranche must be repeated as many times as there are tranches for the market location stated in SG2 from DTM+203 (execution date) onwards. |
| **[2097]** | The SG29 must be repeated as often as required so that at least one SG29 exists for all tranches stated in SG3 reference to ID of the tranche. |
| **[2098]** | The SG2 supplier at the location must be repeated as often as required so that exactly one SG2 supplier of the location exists for all tranches stated in SG3 reference to ID of the tranche. |
| **[2099]** | The SG2 supplier at the location must be stated exactly once. |

</div>

## UB conditions

UB conditions combine several markers into a single expression. In the handbook rows they appear like a condition, but they resolve into the markers they contain.

<div className="maco-tabellenrahmen">

| Marker | Printout |
|---|---|
| **[UB1]** | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |
| **[UB2]** | ([931] ∧ [934] [490]) ⊻ ([931] ∧ [935] [491]) |
| **[UB3]** | ([931] ∧ [932] [492] ∧ [490]) ⊻ ([931] ∧ [933] [492] ∧ [491]) ⊻ ([931] ∧ [934] [493] ∧ [490]) ⊻ ([931] ∧ [935] [493] ∧ [491]) |

</div>

## Condition packages

Condition packages bundle prerequisites.

<div className="maco-tabellenrahmen">

| Package | Prerequisites | Conditions |
|---|---|---|
| **[10P]** | [ 84 ]  ∧  [85 ]  ∧  [79] | [84] IMD++Z14+Z07 present 	 	 [8 5 ]  If in the same SG29 with Z 54  in LIN DE1229  (Required product of the market location), the PIA+5+ 9991000000086 :Z11  (active energy highest 1/4 hour in the month) is present 	 	 [79] If another SG29 with Z 54  in LIN DE1229  (Required product of the market location) with PIA+5+ 9991000000078 :Z11  (for active energy load curve 1/4-hourly) is present |
| **[11P]** | [35 ]  ∧  [76 ]  ∧  [8 0 ] | [35] IMD++Z14+Z06 present 	 	 [7 6 ] If in the same SG29 with Z 54  in LIN DE1229  (Required product of the market location) the PIA+5 DE7140 with a metering product from the code list of the configurations,  Kapitel 2.1.1  „ Standard metering product of the market location with the option of assigning a metering time period “  is present 	 	 [80] If no other SG29 with Z 54  in LIN DE1229  (Required product of the market location) with PIA+5+ 9991000000078 :Z11  (active energy load curve 1/4-hourly) is present |
| **[12P]** | [91] | [91]  If no other package in this SG30 in the same SG29 LIN leads to the possibility of specifying at least one other code in this data element. |
| **[1P]** | -- | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
| **[2P]** | [78] | [78] If in the same SG29 with Z55 in LIN DE1229 (Required product of the grid location) the PIA+5 DE7140 with a metering product from the code list of the configurations, chapter 2 „Code list of the standard metering product electricity for values according to type 1“ with the value property „reactive energy“ is present. |
| **[3P]** | [84 ]  ∧  [76 ]  ∧  [79] | [84] IMD++Z14+Z07 present 	 	 [7 6 ] If in the same SG29 with Z 54  in LIN DE1229  (Required product of the market location) the PIA+5 DE7140 with a metering product from the code list of the configurations,  Kapitel 2.1.1  „ Standard metering product of the market location with the option of assigning a metering time period “  is present 	 	 [ 79 ] If another  SG29 with Z 54  in LIN DE1229  (Required product of the market location)   with PIA+5+ 9991000000078 :Z11  (for active energy load curve 1/4-hourly) is present |
| **[4P]** | [84 ]  ∧  [76 ]  ∧  [80] | [84] IMD++Z14+Z07 present 	 	 [7 6 ] If in the same SG29 with  Z54  in LIN DE1229  (Required product of the market location) the PIA+5 DE7140 with a metering product from the code list of the configurations,  Kapitel 2.1.1  „ Standard metering product of the market location with the option of assigning a metering time period “  is present 	 	 [80] If no other SG29 with Z 54  in LIN DE1229  (Required product of the market location)   with PIA+5+ 9991000000078 :Z11  (active energy load curve 1/4-hourly) is present |
| **[5P]** | [84 ]  ∧  [81 ]  ∧  [82] | [84] IMD++Z14+Z07 present 	 	 [81] If in the same SG29 with Z 54  in LIN DE1229   (Required product of the market location), the PIA+5+ 9991000000078 :Z11  (active energy load curve 1/4-hourly) is present 	 	 [ 82 ]  If another SG29 with Z 54  in LIN DE1229   (Required product of the market location) with PIA+5 DE7140 with a metering product from the code list of the configurations,  Kapitel 2.1.1  „ Standard metering product of the market location with the option of assigning a metering time period “  is present |
| **[6P]** | [84 ]  ∧  [81 ]  ∧  [83] | [84] IMD++Z14+Z07 present 	 	 [81] If in the same SG29 with Z 54  in LIN DE1229   (Required product of the market location), the PIA+5+ 9991000000078 :Z11  (active energy load curve 1/4-hourly) is present 	 	 [83] If no other SG29 with Z 54  in LIN DE1229  (Required product of the market location) with PIA+5 DE7140 with a metering product from the code list of the configurations  Kapitel 2.1.1  „ Standard metering product of the market location with the option of assigning a metering time period “  is present |
| **[7P]** | [35 ]  ∧  [81 ]  ∧  [82] | [35] IMD++Z14+Z06 present 	 	 [81] If in the same SG29 with Z 54  in LIN DE1229   (Required product of the market location), the PIA+5+ 9991000000078 :Z11  (active energy load curve 1/4-hourly) is present 	 	 [82] If another SG29 with Z 54  in LIN DE1229  (Required product of the market location) with PIA+5 DE7140 with a metering product from the code list of the configurations,  Kapitel 2.1.1  „ Standard metering product of the market location with the option of assigning a metering time period “  is present |
| **[8P]** | [35 ]  ∧  [81 ]  ∧  [83] | [35] IMD++Z14+Z06 present 	 	 [81] If in the same SG29 with Z 54  in LIN DE1229   (Required product of the market location), the PIA+5+ 9991000000078 :Z11  (active energy load curve 1/4-hourly) is present 	 	 [83] If no other SG29 with Z 54  in LIN DE1229  (Required product of the market location) with PIA+5 DE7140 with a metering product from the code list of the configurations,  Kapitel 2.1.1  „ Standard metering product of the market location with the option of assigning a metering time period “  is present |
| **[9P]** | [35 ]  ∧  [76 ]  ∧  [79] | [35] IMD++Z14+Z06 present 	 	 [7 6 ] If in the same SG29 with Z 54  in LIN DE1229  (Required product of the market location) the PIA+5 DE7140 with a metering product from the code list of the configurations,  Kapitel 2.1.1  „ Standard metering product of the market location with the option of assigning a metering time period “  is present 	 	 [79] If another SG29 with Z 54  in LIN DE1229  (Required product of the market location) with PIA+5+ 9991000000078 :Z11  (for active energy load curve 1/4-hourly) is present |

</div>

<Hinweisbereich>

This page carries the free text of every condition that the application handbook of message type **ORDERS** references in this format version. A row of the handbook writes `Muss [704]`; what [704] requires is here.

The list applies **to the message type**, not to a single check identifier. This is not a simplification but the form of the source: the condition list is present identically in every handbook file of the format.

:::caution{title="Why no assignment to individual check identifiers is given here"}

The intermediate format from which this documentation reads the handbook rows assigns conditions to a **column** — and this assignment is shifted against the original. Measured on 05.09.2026 against UTILMD electricity: the handbook lists `STS DE9013` as `X [360]` (approval codes only) for check identifier **55017** and `X [359]` (rejection codes only) for **55018**; the intermediate format puts `[360]` on 55016 and `[359]` on 55017 **and** 55018. The same applies to `FTX Muss [83]`: at 55018 in the handbook, at 55017 in the intermediate format.

Independently confirmed by the change lists of the source: change IDs 25242, 25821, 25822, 25445 and 25243 explicitly locate [83], [351] and [352] in „Use case 55018 Rejection of contract termination“. No entry assigns them to 55016 or 55017.

That is why the **text** of every condition is given here and nowhere the claim as to which condition applies to which check identifier. Anyone who needs that looks it up in the original application handbook.

:::

:::note{title="9 conditions do not appear in every handbook file"}

The list of conditions is meant to apply across the whole format, but it does not everywhere: the following markers occur in fewer than all 46 files of this format. They are given here nonetheless — leaving out a condition because one file does not carry it would mean letting a reference point into the void again.

[490], [491], [932], [933], [934], [935], [UB1], [UB2], [UB3]

:::

As measured on 05.09.2026, **no** `ahb_expression` in this source points to a package marker — the condition packages are listed on this page because the source carries them, not because a handbook line refers to them.