# Conditions ORDRSP
<span hidden data-pagefind-meta={"title:Conditions ORDRSP — application handbook (FV 202604)"} />

EDIFACT message type **ORDRSP** · format version **202604** · 122 conditions · 1 packages · 2 UB conditions · from 40 handbook file(s)

## Conditions

<div className="maco-tabellenrahmen">

| Marker | Condition |
|---|---|
| **[1]** | If BGM+7 present |
| **[3]** | If MP-ID in SG3 NAD+MS with role NB is present |
| **[4]** | If MP-ID in SG3 NAD+MR with role LF is present |
| **[5]** | If MP-ID in SG3 NAD+MS with role LF is present |
| **[7]** | If MP-ID in SG3 NAD+MR from division Electricity |
| **[9]** | If MP-ID in SG3 NAD+MS with role LF is present |
| **[10]** | If MP-ID in SG3 NAD+MS with role MSB is present |
| **[11]** | If AJT+A09+E_0470 present |
| **[12]** | If the NB can state a non-binding price indication |
| **[13]** | If MP-ID in SG3 NAD+MR from division Gas |
| **[14]** | If MP-ID in SG3 NAD+MR with role MSB is present |
| **[15]** | If MP-ID in SG3 NAD+MR with role NB is present |
| **[16]** | If MP-ID in SG3 NAD+MR with role ÜNB is present |
| **[17]** | The check step code specified here must be assigned in EBD to the cluster consent |
| **[18]** | The check step code specified here must be assigned in EBD to the cluster rejection |
| **[21]** | If IMD++Z01 present |
| **[22]** | If IMD++Z02 present |
| **[23]** | If IMD++Z03 present |
| **[24]** | If BGM+Z51 present |
| **[25]** | If BGM+Z52 present |
| **[27]** | If AJT+A05+E_0470 present |
| **[28]** | If AJT+A99 present |
| **[29]** | MP-ID only from division gas |
| **[30]** | MP-ID only from division electricity |
| **[31]** | MP-ID with role MSB |
| **[32]** | MP-ID with role NB |
| **[33]** | If AJT+A02/A03+E_0488 present |
| **[34]** | if present |
| **[37]** | If the SG8 CUX+2 is present in this message |
| **[38]** | Possible value: ZB4 or ZB5 |
| **[39]** | Possible value: E17 or Z07 |
| **[40]** | If the code in DE3207 contains an "X" in the column "PLZ present" of the "EDI@Energy code list of European country codes" |
| **[41]** | if SG2 AJT (details of an adjustment/change) DE4465 with value ZB5 is present |
| **[42]** | If SG2 AJT+Z07 (response category: rejection (no authorization)) is present |
| **[43]** | If AJT+A02/A03+E_1001 present |
| **[44]** | If AJT+A05+E_1000 present |
| **[45]** | If AJT+A09+E_1000 present |
| **[46]** | If AJT+A06+E_0552 present |
| **[47]** | If AJT+A06+E_0553 present |
| **[48]** | If AJT+A06+E_0554 present |
| **[49]** | only if IMD++Z60 (order cancellation of metering product with metering time period definition of the LF) was present in the original message |
| **[50]** | if the code EM is present in DE3155 in the same COM |
| **[51]** | if the code TE / FX / AJ / AL is present in DE3155 in the same COM |
| **[52]** | if the complaint was a complaint about the rolled-out load curve definitions |
| **[53]** | Transaction number from IDE DE7402 of the UTILTS with BGM+Z59 |
| **[54]** | Transaction number from IDE DE7402 of the UTILTS with BGM+Z80 |
| **[55]** | Transaction number from IDE DE7402 of the UTILTS with BGM+Z81 |
| **[56]** | if SG2 AJT+A02/A03/A06/A07/A10/A11+E_0548 is present |
| **[57]** | if SG2 AJT+A02/A03/A06/A07/A10/A11+E_0549 is present |
| **[58]** | if SG2 AJT+A02/A03/A06/A07+E_0550 is present |
| **[59]** | if SG2 AJT+A02/A03/A06/A07/A10/A11+E_0551 is present |
| **[60]** | if the complaint was a complaint about the overview of metering time definitions |
| **[61]** | if the complaint was a complaint about the overview of switching time definitions |
| **[62]** | if the complaint was a complaint about the overview of load curve definitions |
| **[63]** | Document number from BGM+Z60 DE1004 of the UTILTS |
| **[64]** | Document number from BGM+Z78 DE1004 of the UTILTS |
| **[65]** | Document number from BGM+Z79 DE1004 of the UTILTS |
| **[66]** | if SG2 AJT+A01/A02/A03+E_0544 is present |
| **[67]** | if SG2 AJT+A01/A02/A03+E_0545 is present |
| **[68]** | if SG2 AJT+A02/A03+E_0546 is present |
| **[69]** | if SG2 AJT+A01/A02/A03+E_0547 is present |
| **[70]** | if the complaint was a complaint about the rolled-out metering time definitions |
| **[71]** | if the complaint was a complaint about the rolled-out switching time definitions |
| **[72]** | if AJT+A04+E_0552 is present |
| **[73]** | if AJT+A04+E_0553 is present |
| **[74]** | if AJT+A04+E_0554 is present |
| **[75]** | If this is the response to an order placement in which a metering product from the code list of configurations from chapter 4.6.2 „Values according to type 2 from SMGW“ was ordered. |
| **[76]** | If FTX+Z27 (IP address of the sender) not present |
| **[77]** | If FTX+Z28 (IP range of the sender) not present |
| **[78]** | If AJT+A04+E_0279 present |
| **[79]** | If AJT+A04+E_0283 present |
| **[80]** | If AJT+A05+E_0279 present |
| **[81]** | If AJT+A05+E_0283 present |
| **[82]** | If BGM+Z93 (order placement for an offer for change of the technology of the location) present |
| **[83]** | If BGM+Z12 (change of the technology of the location) present |
| **[490]** | if the value in this DE, at position CCYYMMDDHHMM, is a point in time within the period stated in the table in chapter 3.5 “Overview of German statutory summer time (MESZ)” in the columns: “Summer time (MESZ) from” representation in UTC and “Summer time (MESZ) to” representation in UTC. |
| **[491]** | if the value in this DE, at position CCYYMMDDHHMM, is a point in time within the period stated in the table in chapter 3.6 “Overview of German statutory time (MEZ)” in the columns: “Winter time (MEZ) from” representation in UTC and “Winter time (MEZ) to” representation in UTC. |
| **[492]** | if MP-ID in NAD+MR from division electricity |
| **[493]** | if MP-ID in NAD+MR from division gas |
| **[494]** | The date stated here must be the point in time at which the document was created, or a point in time before that. |
| **[500]** | Note: Indication of a technical contact person for the device takeover |
| **[503]** | Note: Date up to which the MSBA was obliged to continue |
| **[504]** | Note: Corrected where applicable in the case of a time specification in the ORDERS that lies outside the maximum possible continued obligation period. The response then states consent with date change in SG2 AJT. |
| **[513]** | Note: Value from BGM+Z12 (change of the technology of the location) DE1004 of the ORDERS with which the order placement was made. |
| **[518]** | Note: Value from BGM+Z10 DE1004 of the ORDERS with which the order placement was made |
| **[519]** | Note: Value from BGM+7 DE1004 of the ORDERS with which the order placement was made. |
| **[520]** | Note: Value from BGM+Z29 DE1004 of the ORDERS with which the request for the termination of invoice processing was made. |
| **[521]** | Note: Value from BGM+Z14/Z61/Z62 DE1004 of the ORDERS with which the request for master data was made |
| **[522]** | Note: Value from BGM+7/Z28/Z48 DE1004 of the ORDERS with which the request for values was made. |
| **[523]** | Note: Value from BGM+7 DE1004 of the ORDERS with which the request for calorific value and conversion factor was made. |
| **[524]** | Note: Value from BGM+Z14 DE1004 of the ORDERS with which the request from the MSB gas was made. |
| **[525]** | Note: Value from BGM+Z24 DE1004 of the ORDERS with which the request for the allocation list was made |
| **[526]** | Note: Value from BGM+Z23 DE1004 of the ORDERS with which the request for the balanced quantity was made |
| **[527]** | Note: Value from BGM+Z34 DE1004 of the ORDERS with which the complaint regarding values was made. |
| **[529]** | Note: Document number from BGM DE1004 of the ORDERS |
| **[530]** | Note: Document number from BGM DE1004 of the ORDCHG |
| **[533]** | Note: Value from BGM+Z51 DE1004 of the ORDCHG |
| **[534]** | Note: Value from BGM+Z52 DE1004 of the ORDCHG |
| **[535]** | Note: Value from BGM+Z13 DE1004 of the ORDERS with which the announcement of the device replacement intent was made. |
| **[536]** | Note: The MP-ID of the owner (MSB) must be specified for bilateral clarification if the requested MSB is not the owner itself. |
| **[537]** | Note: Value from BGM+Z72 DE1004 of the ORDERS with which the order placement for the termination of the configuration was made. |
| **[538]** | Note: Value from BGM+Z76 DE1004 of the ORDERS with which the complaint regarding the configuration was made. |
| **[539]** | Note: Value from BGM+Z73/Z74 DE1004 of the ORDERS with which the order placement for the configuration was made. |
| **[540]** | Note: Only one piece of information may be transmitted in DE3148 |
| **[542]** | Note: Value from BGM+Z91 DE1004 of the ORDERS with which the order placement for the change of the billing data was made. |
| **[543]** | Note: Value from BGM+Z93 (order placement for a quotation for the change of the technology of the location) DE1004 of the ORDERS with which the order placement was made. |
| **[544]** | Note: Value from BGM DE1004 of the PRICAT with which price sheet B of the MSB on which the quotation is based from the point of view of the MSB was transmitted. |
| **[545]** | Note: Statement of the start point in time of the realistically possible implementation date that can be determined at the point in time of the rejection. |
| **[546]** | Note: Indication of the end point in time of the realistically possible implementation date that can be determined at the point in time of the rejection. |
| **[547]** | Note: If this concerns the order placement of a previous quotation within the scope of the BDEW application guide "Processes for changing the technology at locations". |
| **[548]** | Note: Note: if it concerns the order issuance of a change in accordance with WiM Part1 UC "metering location change". |
| **[902]** | Format: Format: possible value: ≥ 0 |
| **[903]** | Format: Possible value: 1 |
| **[930]** | Format: max. 2 decimal places |
| **[931]** | Format: ZZZ = +00 |
| **[932]** | Format: HHMM = 2200 |
| **[933]** | Format: HHMM = 2300 |
| **[934]** | Format: HHMM = 0400 |
| **[935]** | Format: HHMM = 0500 |
| **[939]** | Format: the character string must contain the characters @ and . |
| **[940]** | Format: the character string must begin with the character + and may only be followed by digits |
| **[2036]** | The SG27 must be specified exactly once per message |

</div>

## UB conditions

UB conditions combine several markers into a single expression. In the handbook rows they appear like a condition, but they resolve into the markers they contain.

<div className="maco-tabellenrahmen">

| Marker | Printout |
|---|---|
| **[UB1]** | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |
| **[UB3]** | ([931] ∧ [932] [492] ∧ [490]) ⊻ ([931] ∧ [933] [492] ∧ [491]) ⊻ ([931] ∧ [934] [493] ∧ [490]) ⊻ ([931] ∧ [935] [493] ∧ [491]) |

</div>

## Condition packages

Condition packages bundle prerequisites.

<div className="maco-tabellenrahmen">

| Package | Prerequisites | Conditions |
|---|---|---|
| **[1P]** | -- | Note: This is the standard package if no condition applies, e.g. in the COM segment. |

</div>

<Hinweisbereich>

This page carries the free text of every condition that the application handbook of message type **ORDRSP** references in this format version. A row of the handbook writes `Muss [704]`; what [704] requires is here.

The list applies **to the message type**, not to a single check identifier. This is not a simplification but the form of the source: the condition list is present identically in every handbook file of the format.

:::caution{title="Why no assignment to individual check identifiers is given here"}

The intermediate format from which this documentation reads the handbook rows assigns conditions to a **column** — and this assignment is shifted against the original. Measured on 05.09.2026 against UTILMD electricity: the handbook lists `STS DE9013` as `X [360]` (approval codes only) for check identifier **55017** and `X [359]` (rejection codes only) for **55018**; the intermediate format puts `[360]` on 55016 and `[359]` on 55017 **and** 55018. The same applies to `FTX Muss [83]`: at 55018 in the handbook, at 55017 in the intermediate format.

Independently confirmed by the change lists of the source: change IDs 25242, 25821, 25822, 25445 and 25243 explicitly locate [83], [351] and [352] in „Use case 55018 Rejection of contract termination“. No entry assigns them to 55016 or 55017.

That is why the **text** of every condition is given here and nowhere the claim as to which condition applies to which check identifier. Anyone who needs that looks it up in the original application handbook.

:::

:::note{title="8 conditions do not appear in every handbook file"}

The list of conditions is meant to apply across the whole format, but it does not everywhere: the following markers occur in fewer than all 40 files of this format. They are given here nonetheless — leaving out a condition because one file does not carry it would mean letting a reference point into the void again.

[490], [491], [932], [933], [934], [935], [UB1], [UB3]

:::

As measured on 05.09.2026, **no** `ahb_expression` in this source points to a package marker — the condition packages are listed on this page because the source carries them, not because a handbook line refers to them.

</Hinweisbereich>
