# Check identifier 21047 — Processing status message

<span hidden data-pagefind-meta={"title:Check identifier 21047 — Processing status message · IFTSTA · Format version 202604"} />

Check identifier **21047** · EDIFACT message type **IFTSTA** · Format version **202604**

## Data structure

<Handbuchsatz>

<div className="maco-tabellenrahmen">

| Structure (BO4E) | Description | Format | <span className="hbs-p" title="Bearbeitungsstandsmeldung">21047</span> | Condition |
|---|---|---|---|---|
| <span className="hbs-g hbs-e0">**stammdaten** <span className="hbs-pflicht">\*</span></span> | — | object | Must | — |
| <span className="hbs-g hbs-e1">**STATUSMITTEILUNG** <span className="hbs-liste">[ ]</span> <span className="hbs-pflicht">\*</span></span> | — | object[] | Must | — |
| <span className="hbs-f hbs-e2">[auftragsstatus](/en/bo4e/202604/bo/Statusmitteilung#auftragsstatus) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="21047" format="IFTSTA" fv="202604" zeile={37} segment="SG14.CNI.SG15.STS+Z43" /><span className="hbs-nr">00010</span> | Order status | [Enum Auftragsstatus](/en/bo4e/202604/enum/Auftragsstatus) | X | — |
| <span className="hbs-w hbs-e3">`GESCHEITERT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`ERFOLGREICH`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`LIEFERUNG_GEPLANT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`GEPLANT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`ZUGESTIMMT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`WIDERSPROCHEN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`STOERUNGSFREI`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`GESTOERT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`FESTGESTELLTE_STOERUNG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`VERMUTETE_STOERUNG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`ABGELEHNT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`BEENDET`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`ANTWORT_DRITTER`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`BESTAETIGT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`UMGESETZT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`ENFG_STROMSPEICHER_UND_VERLUSTENERGIE`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`ENFG_ELEKTRISCH_ANGETRIEBENE_WAERMEPUMPEN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`ENFG_UMLAGEERHEBUNG_BEI_ANLAGEN_ZUR_VERSTROMUNG_VON_KUPPELGASEN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`ENFG_HERSTELLUNG_VON_GRUENEN_WASSERSTOFF`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`ENFG_STROMKOSTENINTENSIVE_UNTERNEHMEN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`ENFG_HERSTELLUNG_VON_WASSERSTOFF_IN_STROMKOSTENINTENSIVEN_UNTERNEHMEN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`ENFG_SCHIENENBAHNEN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`ENFG_ELEKTRISCHE_BETRIEBENE_BUSSEN_IM_LINIENVERKEHR`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`ENFG_LANDSTROMANLAGEN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`AENDERUNG_DER_DATEN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`KEINE_AENDERUNG_DER_DATEN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`ZEITREIHE_AKZEPTIERT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`ZEITREIHE_NICHT_AKZEPTIERT`</span> | — | — | X | — |
| <span className="hbs-f hbs-e2">[statusObjekt](/en/bo4e/202604/bo/Statusmitteilung#statusobjekt) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="21047" format="IFTSTA" fv="202604" zeile={37} segment="SG14.CNI.SG15.STS+Z43" /><span className="hbs-nr">00020</span> | Status object | [Enum Statusobjekt](/en/bo4e/202604/enum/Statusobjekt) | X | — |
| <span className="hbs-w hbs-e3">`MSBWECHSEL`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`UMBAUMELO`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`ERSTEINBAUIMS`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`ERSTEINBAUMME`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`GERAET`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`ANGEBOTANFRAGE`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`STATUSBESTELLUNG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`LIEFERSCHEIN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`SPERREN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`ENTSPERREN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`PRIVILEGIERUNG_NACH_ENFG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`VERAENDERUNGSSTATUS_DER_DATEN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`TURNUSAUSLESUNG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`PRUEFSTATUS_ANTWORT_SUMMENZEITREIHEN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`ABWEISUNG_SUMMENZEITREIHE`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`PRUEFSTATUS_SUMMENZEITREIHE`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`DATENSTATUS_SUMMENZEITREIHE`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`ABWEISUNG_STATUSMELDUNG_AENDERUNG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`AUSFALLARBEIT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`FAHRPLANANTEIL`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`GEGENVORSCHLAG_AUSFALLARBEIT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`GEGENVORSCHLAG_FAHRPLANANTEIL`</span> | — | — | X | — |
| <span className="hbs-g hbs-e2">**positionsdaten** <span className="hbs-liste">[ ]</span> <span className="hbs-pflicht">\*</span></span> | — | object[] | Must | — |
| <span className="hbs-f hbs-e3">[positionsnummer](/en/bo4e/202604/com/StatusmitteilungPosition#positionsnummer) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="21047" format="IFTSTA" fv="202604" zeile={34} segment="SG14.CNI" /><span className="hbs-nr">00030</span> | positionsnummer | integer | Must | — |
| <span className="hbs-g hbs-e3">**allgemeineInformationen**</span> | — | object | May | — |
| <span className="hbs-f hbs-e4">[info1](/en/bo4e/202604/com/AllgemeineInformationen#info1)</span> <AhbTabelle pruefid="21047" format="IFTSTA" fv="202604" zeile={74} segment="SG14.CNI.SG15.STS+Z43.SG25.GID.FTX+ACB" /><span className="hbs-nr">00040</span> | General info 1 | string | X | — |
| <span className="hbs-f hbs-e4">[info2](/en/bo4e/202604/com/AllgemeineInformationen#info2)</span> <AhbTabelle pruefid="21047" format="IFTSTA" fv="202604" zeile={74} segment="SG14.CNI.SG15.STS+Z43.SG25.GID.FTX+ACB" /><span className="hbs-nr">00050</span> | General info 2 | string | X | — |
| <span className="hbs-f hbs-e4">[info3](/en/bo4e/202604/com/AllgemeineInformationen#info3)</span> <AhbTabelle pruefid="21047" format="IFTSTA" fv="202604" zeile={74} segment="SG14.CNI.SG15.STS+Z43.SG25.GID.FTX+ACB" /><span className="hbs-nr">00060</span> | General info 3 | string | X | — |
| <span className="hbs-f hbs-e4">[info4](/en/bo4e/202604/com/AllgemeineInformationen#info4)</span> <AhbTabelle pruefid="21047" format="IFTSTA" fv="202604" zeile={74} segment="SG14.CNI.SG15.STS+Z43.SG25.GID.FTX+ACB" /><span className="hbs-nr">00070</span> | General info 4 | string | X | — |
| <span className="hbs-f hbs-e4">[info5](/en/bo4e/202604/com/AllgemeineInformationen#info5)</span> <AhbTabelle pruefid="21047" format="IFTSTA" fv="202604" zeile={74} segment="SG14.CNI.SG15.STS+Z43.SG25.GID.FTX+ACB" /><span className="hbs-nr">00080</span> | General info 5 | string | X | — |
| <span className="hbs-g hbs-e0">**transaktionsdaten** <span className="hbs-pflicht">\*</span></span> | — | object | Must | — |
| <span className="hbs-f hbs-e1">[antwortstatus](/en/bo4e/202604/cdoc/Transaktionsdaten#antwortstatus) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="21047" format="IFTSTA" fv="202604" zeile={37} segment="SG14.CNI.SG15.STS+Z43" /><span className="hbs-nr">00090</span> | Response status / STS+E01 | string | X | — |
| <span className="hbs-f hbs-e1">[antwortstatusCodeliste](/en/bo4e/202604/cdoc/Transaktionsdaten#antwortstatuscodeliste) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="21047" format="IFTSTA" fv="202604" zeile={37} segment="SG14.CNI.SG15.STS+Z43" /><span className="hbs-nr">00100</span> | Response status code list / STS+E01 | string | X | — |
| <span className="hbs-f hbs-e1">[dokumentennummer](/en/bo4e/202604/cdoc/Transaktionsdaten#dokumentennummer) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="21047" format="IFTSTA" fv="202604" zeile={8} segment="BGM+Z33" /><span className="hbs-nr">00110</span> | EDIFACT reference from the BGM segment / BGM | string | X | — |
| <span className="hbs-f hbs-e1">[nachrichtendatum](/en/bo4e/202604/cdoc/Transaktionsdaten#nachrichtendatum) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="21047" format="IFTSTA" fv="202604" zeile={11} segment="DTM+137" /><span className="hbs-nr">00120</span> | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| <span className="hbs-f hbs-e1">[nachrichtenreferenznummer](/en/bo4e/202604/cdoc/Transaktionsdaten#nachrichtenreferenznummer) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="21047" format="IFTSTA" fv="202604" zeile={0} segment="UNH" /><span className="hbs-nr">00130</span> | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| <span className="hbs-f hbs-e1">[pruefidentifikator](/en/bo4e/202604/cdoc/Transaktionsdaten#pruefidentifikator) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="21047" format="IFTSTA" fv="202604" zeile={66} segment="SG14.CNI.SG15.STS+Z43.RFF+Z13" /><span className="hbs-nr">00140</span> | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| <span className="hbs-f hbs-e1">[sendungsposition](/en/bo4e/202604/cdoc/Transaktionsdaten#sendungsposition)</span> <AhbTabelle pruefid="21047" format="IFTSTA" fv="202604" zeile={71} segment="SG14.CNI.SG15.STS+Z43.SG25.GID" /><span className="hbs-nr">00150</span> | Consignment item / GID | string | Must | — |
| <span className="hbs-f hbs-e1">[vorgangsreferenznummer](/en/bo4e/202604/cdoc/Transaktionsdaten#vorgangsreferenznummer) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="21047" format="IFTSTA" fv="202604" zeile={69} segment="SG14.CNI.SG15.STS+Z43.RFF+ACW" /><span className="hbs-nr">00160</span> | Reference number of the transaction of the registration according to WiM / ORDERS RFF+Z41 / IFTSTA RFF+ACW | string | X | — |
| <span className="hbs-g hbs-e1">**absender** <span className="hbs-pflicht">\*</span></span> | — | object | Must | — |
| <span className="hbs-f hbs-e2">[rollencodenummer](/en/bo4e/202604/bo/Marktteilnehmer#rollencodenummer) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="21047" format="IFTSTA" fv="202604" zeile={20} segment="SG1.NAD+MS" /><span className="hbs-nr">00170</span> | Specifies the code value of the market role. | string | X | — |
| <span className="hbs-f hbs-e2">[rollencodetyp](/en/bo4e/202604/bo/Marktteilnehmer#rollencodetyp) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="21047" format="IFTSTA" fv="202604" zeile={20} segment="SG1.NAD+MS" /><span className="hbs-nr">00180</span> | Indicates the type of the code. | [Enum Rollencodetyp](/en/bo4e/202604/enum/Rollencodetyp) | X | — |
| <span className="hbs-w hbs-e3">`BDEW`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`GS1`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`GLN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`DVGW`</span> | — | — | X | — |
| <span className="hbs-g hbs-e2">**ansprechpartner**</span> | — | object | May | — |
| <span className="hbs-f hbs-e3">[eMailAdresse](/en/bo4e/202604/bo/Ansprechpartner#emailadresse)</span> <AhbTabelle pruefid="21047" format="IFTSTA" fv="202604" zeile={27} segment="SG1.NAD+MS.SG2.CTA+IC.COM+[EM\|FX\|TE\|AJ\|AL]" /><span className="hbs-nr">00190</span> | Email address | string | Must | — |
| <span className="hbs-f hbs-e3">[nachname](/en/bo4e/202604/bo/Ansprechpartner#nachname)</span> <AhbTabelle pruefid="21047" format="IFTSTA" fv="202604" zeile={25} segment="SG1.NAD+MS.SG2.CTA+IC" /><span className="hbs-nr">00200</span> | Surname (family name) of the contact person | string | X | — |
| <span className="hbs-g hbs-e3">**rufnummern** <span className="hbs-liste">[ ]</span></span> | — | object[] | May | — |
| <span className="hbs-f hbs-e4">[nummerntyp](/en/bo4e/202604/com/Rufnummer#nummerntyp)</span> <AhbTabelle pruefid="21047" format="IFTSTA" fv="202604" zeile={27} segment="SG1.NAD+MS.SG2.CTA+IC.COM+[EM\|FX\|TE\|AJ\|AL]" /><span className="hbs-nr">00210</span> | Phone number type | [Enum Rufnummernart](/en/bo4e/202604/enum/Rufnummernart) | Must | — |
| <span className="hbs-w hbs-e5">`RUF_ZENTRALE`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`FAX_ZENTRALE`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`SAMMELRUF`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`SAMMELFAX`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`ABTEILUNGRUF`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`ABTEILUNGFAX`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`RUF_DURCHWAHL`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`FAX_DURCHWAHL`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`MOBIL_NUMMER`</span> | — | — | Must | — |
| <span className="hbs-f hbs-e4">[rufnummer](/en/bo4e/202604/com/Rufnummer#rufnummer)</span> <AhbTabelle pruefid="21047" format="IFTSTA" fv="202604" zeile={27} segment="SG1.NAD+MS.SG2.CTA+IC.COM+[EM\|FX\|TE\|AJ\|AL]" /><span className="hbs-nr">00220</span> | rufnummer | string | Must | — |
| <span className="hbs-g hbs-e1">**empfaenger** <span className="hbs-pflicht">\*</span></span> | — | object | Must | — |
| <span className="hbs-f hbs-e2">[rollencodenummer](/en/bo4e/202604/bo/Marktteilnehmer#rollencodenummer) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="21047" format="IFTSTA" fv="202604" zeile={15} segment="SG1.NAD+MR" /><span className="hbs-nr">00230</span> | Specifies the code value of the market role. | string | X | — |
| <span className="hbs-f hbs-e2">[rollencodetyp](/en/bo4e/202604/bo/Marktteilnehmer#rollencodetyp) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="21047" format="IFTSTA" fv="202604" zeile={15} segment="SG1.NAD+MR" /><span className="hbs-nr">00240</span> | Indicates the type of the code. | [Enum Rollencodetyp](/en/bo4e/202604/enum/Rollencodetyp) | X | — |
| <span className="hbs-w hbs-e3">`BDEW`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`GS1`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`GLN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`DVGW`</span> | — | — | X | — |

</div>

</Handbuchsatz>

## Application handbook (AHB)

<Handbuchsatz>

<div className="maco-tabellenrahmen" data-maco="ahb-tabelle">

| Structure (EDIFACT) | Description | Format | <span className="hbs-p" title="Bearbeitungsstandsmeldung">21047</span> | Condition |
|---|---|---|---|---|
| <span className="hbs-g hbs-e0">**UNH**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`0062`</span><span className="hbs-nr">00010</span> | Message reference number | — | X | — |
| <span className="hbs-f hbs-e1">`0065 IFTSTA`</span><span className="hbs-nr">00020</span> | Multimodal status report | — | X | — |
| <span className="hbs-f hbs-e1">`0052 D`</span><span className="hbs-nr">00030</span> | Draft version | — | X | — |
| <span className="hbs-f hbs-e1">`0054 18A`</span><span className="hbs-nr">00040</span> | Edition 2018 - A | — | X | — |
| <span className="hbs-f hbs-e1">`0051 UN`</span><span className="hbs-nr">00050</span> | UN/CEFACT | — | X | — |
| <span className="hbs-f hbs-e1">`0057 2.0g`</span><span className="hbs-nr">00060</span> | Version number of the underlying BDEW message description | — | X | — |
| <span className="hbs-g hbs-e0">**BGM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1001 Z33`</span><span className="hbs-nr">00070</span> | GPKE message(s) | — | X | — |
| <span className="hbs-f hbs-e1">`1004`</span><span className="hbs-nr">00080</span> | Document number | — | X | — |
| <span className="hbs-g hbs-e0">**DTM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`2005 137`</span><span className="hbs-nr">00090</span> | Document-/ message date/time | — | X | — |
| <span className="hbs-f hbs-e1">`2380`</span><span className="hbs-nr">00100</span> | Date or time or time span, value | — | X | <span className="hbs-marke">[931]</span> <span className="hbs-marke">[494]</span> |
| <span className="hbs-f hbs-e1">`2379 303`</span><span className="hbs-nr">00110</span> | CCYYMMDDHHMMZZZ | — | X | — |
| <span className="hbs-g hbs-e0">**SG1.NAD**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3035 MR`</span><span className="hbs-nr">00120</span> | Message recipient | — | X | — |
| <span className="hbs-f hbs-e1">`3039`</span><span className="hbs-nr">00130</span> | MP-ID | — | X | <span className="hbs-marke">[27]</span> |
| <span className="hbs-f hbs-e1">`3055 9`</span><span className="hbs-nr">00140</span> | GS1 | — | X | — |
| <span className="hbs-f hbs-e1">`3055 293`</span><span className="hbs-nr">00150</span> | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| <span className="hbs-g hbs-e0">**SG1.NAD**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3035 MS`</span><span className="hbs-nr">00160</span> | Document-/ message sender or sender | — | X | — |
| <span className="hbs-f hbs-e1">`3039`</span><span className="hbs-nr">00170</span> | MP-ID | — | X | <span className="hbs-marke">[27]</span> |
| <span className="hbs-f hbs-e1">`3055 9`</span><span className="hbs-nr">00180</span> | GS1 | — | X | — |
| <span className="hbs-f hbs-e1">`3055 293`</span><span className="hbs-nr">00190</span> | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| <span className="hbs-g hbs-e0">**SG2.CTA**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3139 IC`</span><span className="hbs-nr">00200</span> | Information contact | — | X | — |
| <span className="hbs-f hbs-e1">`3412`</span><span className="hbs-nr">00210</span> | Contact | — | X | — |
| <span className="hbs-g hbs-e0">**SG2.COM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3148`</span><span className="hbs-nr">00220</span> | Number / email address | — | X | ((<span className="hbs-marke">[939]</span><span className="hbs-marke">[146]</span>) ∨ (<span className="hbs-marke">[940]</span> <span className="hbs-marke">[147]</span>)) ∧ <span className="hbs-marke">[534]</span> |
| <span className="hbs-f hbs-e1">`3155 EM`</span><span className="hbs-nr">00230</span> | Email | — | X | <span className="hbs-marke">[1P0..1]</span> |
| <span className="hbs-f hbs-e1">`3155 FX`</span><span className="hbs-nr">00240</span> | Fax number | — | X | <span className="hbs-marke">[1P0..1]</span> |
| <span className="hbs-f hbs-e1">`3155 TE`</span><span className="hbs-nr">00250</span> | Telephone | — | X | <span className="hbs-marke">[1P0..1]</span> |
| <span className="hbs-f hbs-e1">`3155 AJ`</span><span className="hbs-nr">00260</span> | further telephone | — | X | <span className="hbs-marke">[1P0..1]</span> |
| <span className="hbs-f hbs-e1">`3155 AL`</span><span className="hbs-nr">00270</span> | Mobile phone | — | X | <span className="hbs-marke">[1P0..1]</span> |
| <span className="hbs-g hbs-e0">**SG14.CNI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1490`</span><span className="hbs-nr">00280</span> | Transaction number | — | X | <span className="hbs-marke">[911]</span> |
| <span className="hbs-g hbs-e0">**SG15.STS**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`9015 Z43`</span><span className="hbs-nr">00290</span> | Change status of the data | — | X | — |
| <span className="hbs-f hbs-e1">`4405 Z47`</span><span className="hbs-nr">00300</span> | Change of the data | — | X | — |
| <span className="hbs-f hbs-e1">`4405 Z48`</span><span className="hbs-nr">00310</span> | no change to the data | — | X | — |
| <span className="hbs-f hbs-e1">`9013`</span><span className="hbs-nr">00320</span> | Code of the check step | — | X | <span className="hbs-marke">[100]</span> ⊻ <span className="hbs-marke">[101]</span> |
| <span className="hbs-f hbs-e1">`1131 E_0573`</span><span className="hbs-nr">00330</span> | EBD no. E_0573 | — | X | <span className="hbs-marke">[115]</span> ∧ <span className="hbs-marke">[20]</span> |
| <span className="hbs-f hbs-e1">`1131 E_0576`</span><span className="hbs-nr">00340</span> | EBD no. E_0576 | — | X | <span className="hbs-marke">[115]</span> ∧ <span className="hbs-marke">[117]</span> |
| <span className="hbs-f hbs-e1">`1131 E_0577`</span><span className="hbs-nr">00350</span> | EBD no. E_0577 | — | X | <span className="hbs-marke">[115]</span> ∧ <span className="hbs-marke">[29]</span> |
| <span className="hbs-f hbs-e1">`1131 E_0584`</span><span className="hbs-nr">00360</span> | EBD no. E_0584 | — | X | <span className="hbs-marke">[114]</span> ∧ <span className="hbs-marke">[117]</span> |
| <span className="hbs-f hbs-e1">`1131 E_0585`</span><span className="hbs-nr">00370</span> | EBD no. E_0585 | — | X | <span className="hbs-marke">[114]</span> ∧ <span className="hbs-marke">[20]</span> |
| <span className="hbs-f hbs-e1">`1131 E_0586`</span><span className="hbs-nr">00380</span> | EBD no. E_0586 | — | X | <span className="hbs-marke">[114]</span> ∧ <span className="hbs-marke">[26]</span> |
| <span className="hbs-f hbs-e1">`1131 E_0587`</span><span className="hbs-nr">00390</span> | EBD no. E_0587 | — | X | <span className="hbs-marke">[114]</span> ∧ <span className="hbs-marke">[29]</span> |
| <span className="hbs-f hbs-e1">`1131 E_0588`</span><span className="hbs-nr">00400</span> | EBD no. E_0588 | — | X | <span className="hbs-marke">[86]</span> ∧ <span className="hbs-marke">[26]</span> |
| <span className="hbs-f hbs-e1">`1131 E_0589`</span><span className="hbs-nr">00410</span> | EBD no. E_0589 | — | X | <span className="hbs-marke">[86]</span> ∧ <span className="hbs-marke">[117]</span> |
| <span className="hbs-f hbs-e1">`1131 E_0595`</span><span className="hbs-nr">00420</span> | EBD no. E_0595 | — | X | <span className="hbs-marke">[115]</span> ∧ <span className="hbs-marke">[20]</span> |
| <span className="hbs-f hbs-e1">`1131 E_0613`</span><span className="hbs-nr">00430</span> | EBD no. E_0613 | — | X | <span className="hbs-marke">[115]</span> ∧ <span className="hbs-marke">[29]</span> |
| <span className="hbs-f hbs-e1">`1131 E_0616`</span><span className="hbs-nr">00440</span> | EBD no. E_0616 | — | X | <span className="hbs-marke">[115]</span> ∧ <span className="hbs-marke">[29]</span> |
| <span className="hbs-f hbs-e1">`1131 E_0618`</span><span className="hbs-nr">00450</span> | EBD no. E_0618 | — | X | <span className="hbs-marke">[115]</span> ∧ <span className="hbs-marke">[29]</span> |
| <span className="hbs-f hbs-e1">`1131 E_0619`</span><span className="hbs-nr">00460</span> | EBD no. E_0619 | — | X | <span className="hbs-marke">[115]</span> ∧ <span className="hbs-marke">[20]</span> |
| <span className="hbs-f hbs-e1">`1131 E_0620`</span><span className="hbs-nr">00470</span> | EBD no. E_0620 | — | X | <span className="hbs-marke">[115]</span> ∧ <span className="hbs-marke">[20]</span> |
| <span className="hbs-f hbs-e1">`1131 E_0626`</span><span className="hbs-nr">00480</span> | EBD no. E_0626 | — | X | <span className="hbs-marke">[115]</span> ∧ <span className="hbs-marke">[20]</span> |
| <span className="hbs-f hbs-e1">`1131 E_0627`</span><span className="hbs-nr">00490</span> | EBD no. E_0627 | — | X | <span className="hbs-marke">[115]</span> ∧ <span className="hbs-marke">[117]</span> |
| <span className="hbs-f hbs-e1">`1131 E_0628`</span><span className="hbs-nr">00500</span> | EBD no. E_0628 | — | X | <span className="hbs-marke">[115]</span> ∧ <span className="hbs-marke">[29]</span> |
| <span className="hbs-f hbs-e1">`1131 E_0629`</span><span className="hbs-nr">00510</span> | EBD no. E_0629 | — | X | <span className="hbs-marke">[86]</span> ∧ <span className="hbs-marke">[26]</span> |
| <span className="hbs-f hbs-e1">`1131 E_0630`</span><span className="hbs-nr">00520</span> | EBD no. E_0630 | — | X | <span className="hbs-marke">[86]</span> ∧ <span className="hbs-marke">[117]</span> |
| <span className="hbs-f hbs-e1">`1131 E_0632`</span><span className="hbs-nr">00530</span> | EBD no. E_0632 | — | X | <span className="hbs-marke">[114]</span> ∧ <span className="hbs-marke">[26]</span> |
| <span className="hbs-f hbs-e1">`1131 E_0633`</span><span className="hbs-nr">00540</span> | EBD no. E_0633 | — | X | <span className="hbs-marke">[114]</span> ∧ <span className="hbs-marke">[20]</span> |
| <span className="hbs-f hbs-e1">`1131 E_0634`</span><span className="hbs-nr">00550</span> | EBD no. E_0634 | — | X | <span className="hbs-marke">[114]</span> ∧ <span className="hbs-marke">[117]</span> |
| <span className="hbs-f hbs-e1">`1131 E_0635`</span><span className="hbs-nr">00560</span> | EBD no. E_0635 | — | X | <span className="hbs-marke">[114]</span> ∧ <span className="hbs-marke">[29]</span> |
| <span className="hbs-g hbs-e0">**SG15.RFF**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1153 Z13`</span><span className="hbs-nr">00570</span> | Check identifier | — | X | — |
| <span className="hbs-f hbs-e1">`1154 21047`</span><span className="hbs-nr">00580</span> | GPKE / Processing status message | — | X | — |
| <span className="hbs-g hbs-e0">**SG15.RFF**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1153 ACW`</span><span className="hbs-nr">00590</span> | Reference number of a preceding message | — | X | — |
| <span className="hbs-f hbs-e1">`1154`</span><span className="hbs-nr">00600</span> | Reference number | — | X | <span className="hbs-marke">[535]</span> |
| <span className="hbs-g hbs-e0">**SG25.GID**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1496`</span><span className="hbs-nr">00610</span> | Consignment item | — | X | <span className="hbs-marke">[903]</span> |
| <span className="hbs-g hbs-e0">**SG25.FTX**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`4451 ACB`</span><span className="hbs-nr">00620</span> | Additional information (for general notes) | — | X | — |
| <span className="hbs-f hbs-e1">`4440`</span><span className="hbs-nr">00630</span> | Free text | — | X | — |
| <span className="hbs-g hbs-e0">**UNT**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`0074`</span><span className="hbs-nr">00640</span> | Number of segments in a message | — | X | — |
| <span className="hbs-f hbs-e1">`0062`</span><span className="hbs-nr">00650</span> | Message reference number | — | X | — |

</div>

</Handbuchsatz>

### Conditions of this table

The free text of the 21 conditions referenced by the rows above. All conditions of the message type are listed in the [condition index IFTSTA](/en/referenz/202604/ahb-bedingungen/IFTSTA).

<div className="maco-tabellenrahmen">

| Marker | Condition |
|---|---|
| **[20]** | If MP-ID in SG1 NAD+MR in the role LF |
| **[26]** | If MP-ID in SG1 NAD+MR in the role NB |
| **[27]** | Only MP-ID from the electricity division |
| **[29]** | If MP-ID in SG1 NAD+MR in the role ÜNB |
| **[86]** | If MP-ID in SG1 NAD+MS in the role LF |
| **[100]** | If STS+Z43+Z47 present, only codes from the EBD cluster "change of the data" are possible. |
| **[101]** | If STS+Z43+Z48 present, only codes from the EBD cluster "no change of the data" are possible. |
| **[114]** | If MP-ID in SG1 NAD+MS in the role MSB |
| **[115]** | If MP-ID in SG1 NAD+MS in the role NB |
| **[117]** | If MP-ID in SG1 NAD+MR in the role MSB |
| **[146]** | If code EM is present in DE3155 in the same COM |
| **[147]** | If code TE / FX / AJ / AL is present in DE3155 in the same COM |
| **[494]** | The date stated here must be the point in time at which the document was created, or a point in time before that |
| **[534]** | Note: Only one piece of information may be transmitted in DE3148 |
| **[535]** | Note: From UTILMD IDE DE7402 |
| **[903]** | Format: Possible value: 1 |
| **[911]** | Format: Possible values: 1 to n, starting at 1 for each message and ascending consecutively |
| **[931]** | Format: ZZZ = +00 |
| **[939]** | Format: the character string must contain the characters @ and . |
| **[940]** | Format: the character string must begin with the character + and may only be followed by digits |
| **[1P0..1]** | Note: This is the standard package if no condition applies, e.g. in the COM segment. |

</div>

## Example message

<div data-maco="beispielfall" className="maco-beispielfall">

<Beispielnachricht>

```text title="EDIFACT"
UNA:+.? '
UNB+UNOC:3+9900321000005:500+9903790000002:500+{{date}}:{{time}}+M0M56B09'
UNH+UNHM09Y0DVP+IFTSTA:D:18A:UN:2.0g'
BGM+Z33+BGMM0M7F86Z'
DTM+137:202504041200?+00:303'
NAD+MR+9903790000002::293'
NAD+MS+9900321000005::293'
CNI+1'
STS+Z43+Z48+A01:E_0588'
RFF+Z13:21047'
RFF+ACW:ABC12345'
UNT+10+UNHM09Y0DVP'
UNZ+1+M0M56B09'
```

```json title="BO4E-JSON"
[
  {
    "businessKey": "<businessKey>",
    "processDate": null,
    "dataSource": "OUTBOUND",
    "version": 1,
    "edifactVersion": 202604,
    "data": {
      "stammdaten": {
        "STATUSMITTEILUNG": [
          {
            "boTyp": "STATUSMITTEILUNG",
            "versionStruktur": "1",
            "statusObjekt": "VERAENDERUNGSSTATUS_DER_DATEN",
            "auftragsstatus": "KEINE_AENDERUNG_DER_DATEN",
            "positionsdaten": [
              {
                "positionsnummer": 1
              }
            ]
          }
        ]
      },
      "transaktionsdaten": {
        "datenaustauschreferenz": "M0M56B09",
        "sparte": "STROM",
        "pruefidentifikator": "21047",
        "absender": {
          "boTyp": "MARKTTEILNEHMER",
          "versionStruktur": "1",
          "marktrolle": "LF",
          "rollencodenummer": "9900321000005",
          "rollencodetyp": "BDEW"
        },
        "empfaenger": {
          "boTyp": "MARKTTEILNEHMER",
          "versionStruktur": "1",
          "marktrolle": "NB",
          "rollencodenummer": "9903790000002",
          "rollencodetyp": "BDEW"
        },
        "dokumentennummer": "BGMM0M7F86Z",
        "kategorie": "Z33",
        "nachrichtendatum": "2025-04-04T12:00:00Z",
        "nachrichtenreferenznummer": "UNHM09Y0DVP",
        "antwortstatusCodeliste": "E_0588",
        "antwortstatus": "A01",
        "vorgangsreferenznummer": "ABC12345"
      },
      "zusatzdaten": {}
    }
  }
]
```

</Beispielnachricht>

*Source: [`1.edi`](https://github.com/conuti-gmbh/maco-edi-testfiles/blob/main/inbound/v202604/iftsta/21047/1.edi) · [`1.json`](https://github.com/conuti-gmbh/maco-edi-testfiles/blob/main/outbound/v202604/iftsta/21047/1.json)*

<Testdateien edi="/testdaten/202604/iftsta/21047/1.edi" json="/testdaten/202604/iftsta/21047/1.json" />

</div>

## Belongs to these role views

The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are **LF**, **NB**, **MSB** and **ÜNB**.

<div className="maco-tabellenrahmen">

| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | [Billing data for balancing group settlement](/en/prozessdoku/202604/LF/GPKE-Teil2-abrechnungsdaten-bilanzkreisabrechnung) | GPKE part 2 | Electricity | Step 3 |
| LF | LF | [Billing data for balancing group settlement](/en/prozessdoku/202604/LF/GPKE-Teil2-abrechnungsdaten-bilanzkreisabrechnung) | GPKE part 2 | Electricity | Step 6 |
| LF | LF | [Billing data for grid usage settlement](/en/prozessdoku/202604/LF/GPKE-Teil2-abrechnungsdaten-netznutzungsabrechnung) | GPKE part 2 | Electricity | Step 3 |
| LF | LF | [Order placement for a change of billing data from LF to NB](/en/prozessdoku/202604/LF/GPKE-Teil2-bestellung-einer-aenderung-von-abrechnungsdaten-von-lf-an-nb) | GPKE part 2 | Electricity | Step 2 |
| LF | LF | [Order placement for a master data change to the LF (responsible)](/en/prozessdoku/202604/LF/GPKE-Teil4-bestellung-zur-stammdatenaenderung-an-lf-verantwortlich) | GPKE part 4 | Electricity | Step 2 |
| LF | LF | [Order placement for a master data change to the LF (responsible)](/en/prozessdoku/202604/LF/GPKE-Teil4-bestellung-zur-stammdatenaenderung-an-lf-verantwortlich) | GPKE part 4 | Electricity | Step 4 |
| LF | LF | [Order placement for a master data change to the MSB (responsible)](/en/prozessdoku/202604/LF/GPKE-Teil4-bestellung-zur-stammdatenaenderung-an-msb-verantwortlich) | GPKE part 4 | Electricity | Step 2 |
| LF | LF | [Order placement for a master data change to the MSB (responsible)](/en/prozessdoku/202604/LF/GPKE-Teil4-bestellung-zur-stammdatenaenderung-an-msb-verantwortlich) | GPKE part 4 | Electricity | Step 4 |
| LF | LF | [Order placement for a master data change to the MSB (responsible)](/en/prozessdoku/202604/LF/GPKE-Teil4-bestellung-zur-stammdatenaenderung-an-msb-verantwortlich) | GPKE part 4 | Electricity | Step 6 |
| LF | LF | [Order placement for a master data change to the MSB (responsible)](/en/prozessdoku/202604/LF/GPKE-Teil4-bestellung-zur-stammdatenaenderung-an-msb-verantwortlich) | GPKE part 4 | Electricity | Step 8 |
| LF | LF | [Order placement for a master data change to the NB (responsible)](/en/prozessdoku/202604/LF/GPKE-Teil4-bestellung-zur-stammdatenaenderung-an-nb-verantwortlich) | GPKE part 4 | Electricity | Step 2 |
| LF | LF | [Order placement for a master data change to the NB (responsible)](/en/prozessdoku/202604/LF/GPKE-Teil4-bestellung-zur-stammdatenaenderung-an-nb-verantwortlich) | GPKE part 4 | Electricity | Step 4 |
| LF | LF | [Order placement for a master data change to the NB (responsible)](/en/prozessdoku/202604/LF/GPKE-Teil4-bestellung-zur-stammdatenaenderung-an-nb-verantwortlich) | GPKE part 4 | Electricity | Step 6 |
| LF | LF | [Master data change initiated by the LF (responsible)](/en/prozessdoku/202604/LF/GPKE-Teil4-stammdatenaenderung-vom-lf-verantwortlich-ausgehend) | GPKE part 4 | Electricity | Step 3 |
| LF | LF | [Master data change initiated by the LF (responsible)](/en/prozessdoku/202604/LF/GPKE-Teil4-stammdatenaenderung-vom-lf-verantwortlich-ausgehend) | GPKE part 4 | Electricity | Step 6 |
| LF | LF | [Master data change initiated by the MSB (responsible)](/en/prozessdoku/202604/LF/GPKE-Teil4-stammdatenaenderung-vom-msb-verantwortlich-ausgehend) | GPKE part 4 | Electricity | Step 3 |
| LF | LF | [Master data change initiated by the MSB (responsible)](/en/prozessdoku/202604/LF/GPKE-Teil4-stammdatenaenderung-vom-msb-verantwortlich-ausgehend) | GPKE part 4 | Electricity | Step 6 |
| LF | LF | [Master data change initiated by the MSB (responsible)](/en/prozessdoku/202604/LF/GPKE-Teil4-stammdatenaenderung-vom-msb-verantwortlich-ausgehend) | GPKE part 4 | Electricity | Step 9 |
| LF | LF | [Master data change initiated by the MSB (responsible)](/en/prozessdoku/202604/LF/GPKE-Teil4-stammdatenaenderung-vom-msb-verantwortlich-ausgehend) | GPKE part 4 | Electricity | Step 13 |
| LF | LF | [Master data change initiated by the NB (responsible)](/en/prozessdoku/202604/LF/GPKE-Teil4-stammdatenaenderung-vom-nb-verantwortlich-ausgehend) | GPKE part 4 | Electricity | Step 3 |
| LF | LF | [Master data change initiated by the NB (responsible)](/en/prozessdoku/202604/LF/GPKE-Teil4-stammdatenaenderung-vom-nb-verantwortlich-ausgehend) | GPKE part 4 | Electricity | Step 6 |
| LF | LF | [Master data change initiated by the NB (responsible)](/en/prozessdoku/202604/LF/GPKE-Teil4-stammdatenaenderung-vom-nb-verantwortlich-ausgehend) | GPKE part 4 | Electricity | Step 10 |
| NB | NB | [Billing data for balancing group settlement](/en/prozessdoku/202604/NB/GPKE-Teil2-abrechnungsdaten-bilanzkreisabrechnung) | GPKE part 2 | Electricity | Step 3 |
| NB | NB | [Billing data for balancing group settlement](/en/prozessdoku/202604/NB/GPKE-Teil2-abrechnungsdaten-bilanzkreisabrechnung) | GPKE part 2 | Electricity | Step 6 |
| NB | NB | [Billing data for grid usage settlement](/en/prozessdoku/202604/NB/GPKE-Teil2-abrechnungsdaten-netznutzungsabrechnung) | GPKE part 2 | Electricity | Step 3 |
| NB | NB | [Order placement for a change of billing data from LF to NB](/en/prozessdoku/202604/NB/GPKE-Teil2-bestellung-einer-aenderung-von-abrechnungsdaten-von-lf-an-nb) | GPKE part 2 | Electricity | Step 2 |
| NB | NB | [Order placement for a change of billing data for balancing group settlement from ÜNB to NB](/en/prozessdoku/202604/NB/GPKE-Teil2-bestellung-einer-aenderung-von-abrechnungsdaten-zur-bilanzkreisabrechnung-von-uenb-an-nb) | GPKE part 2 | Electricity | Step 2 |
| NB | NB | [Order placement for a master data change to the LF (responsible)](/en/prozessdoku/202604/NB/GPKE-Teil4-bestellung-zur-stammdatenaenderung-an-lf-verantwortlich) | GPKE part 4 | Electricity | Step 2 |
| NB | NB | [Order placement for a master data change to the LF (responsible)](/en/prozessdoku/202604/NB/GPKE-Teil4-bestellung-zur-stammdatenaenderung-an-lf-verantwortlich) | GPKE part 4 | Electricity | Step 4 |
| NB | NB | [Order placement for a master data change to the MSB (responsible)](/en/prozessdoku/202604/NB/GPKE-Teil4-bestellung-zur-stammdatenaenderung-an-msb-verantwortlich) | GPKE part 4 | Electricity | Step 2 |
| NB | NB | [Order placement for a master data change to the MSB (responsible)](/en/prozessdoku/202604/NB/GPKE-Teil4-bestellung-zur-stammdatenaenderung-an-msb-verantwortlich) | GPKE part 4 | Electricity | Step 4 |
| NB | NB | [Order placement for a master data change to the MSB (responsible)](/en/prozessdoku/202604/NB/GPKE-Teil4-bestellung-zur-stammdatenaenderung-an-msb-verantwortlich) | GPKE part 4 | Electricity | Step 6 |
| NB | NB | [Order placement for a master data change to the MSB (responsible)](/en/prozessdoku/202604/NB/GPKE-Teil4-bestellung-zur-stammdatenaenderung-an-msb-verantwortlich) | GPKE part 4 | Electricity | Step 8 |
| NB | NB | [Order placement for a master data change to the NB (responsible)](/en/prozessdoku/202604/NB/GPKE-Teil4-bestellung-zur-stammdatenaenderung-an-nb-verantwortlich) | GPKE part 4 | Electricity | Step 2 |
| NB | NB | [Order placement for a master data change to the NB (responsible)](/en/prozessdoku/202604/NB/GPKE-Teil4-bestellung-zur-stammdatenaenderung-an-nb-verantwortlich) | GPKE part 4 | Electricity | Step 4 |
| NB | NB | [Order placement for a master data change to the NB (responsible)](/en/prozessdoku/202604/NB/GPKE-Teil4-bestellung-zur-stammdatenaenderung-an-nb-verantwortlich) | GPKE part 4 | Electricity | Step 6 |
| NB | NB | [Master data on balancing group integrity](/en/prozessdoku/202604/NB/GPKE-Teil4-stammdaten-zur-bilanzkreistreue) | GPKE part 4 | Electricity | Step 3 |
| NB | NB | [Master data change initiated by the LF (responsible)](/en/prozessdoku/202604/NB/GPKE-Teil4-stammdatenaenderung-vom-lf-verantwortlich-ausgehend) | GPKE part 4 | Electricity | Step 3 |
| NB | NB | [Master data change initiated by the LF (responsible)](/en/prozessdoku/202604/NB/GPKE-Teil4-stammdatenaenderung-vom-lf-verantwortlich-ausgehend) | GPKE part 4 | Electricity | Step 6 |
| NB | NB | [Master data change initiated by the MSB (responsible)](/en/prozessdoku/202604/NB/GPKE-Teil4-stammdatenaenderung-vom-msb-verantwortlich-ausgehend) | GPKE part 4 | Electricity | Step 3 |
| NB | NB | [Master data change initiated by the MSB (responsible)](/en/prozessdoku/202604/NB/GPKE-Teil4-stammdatenaenderung-vom-msb-verantwortlich-ausgehend) | GPKE part 4 | Electricity | Step 6 |
| NB | NB | [Master data change initiated by the MSB (responsible)](/en/prozessdoku/202604/NB/GPKE-Teil4-stammdatenaenderung-vom-msb-verantwortlich-ausgehend) | GPKE part 4 | Electricity | Step 9 |
| NB | NB | [Master data change initiated by the MSB (responsible)](/en/prozessdoku/202604/NB/GPKE-Teil4-stammdatenaenderung-vom-msb-verantwortlich-ausgehend) | GPKE part 4 | Electricity | Step 13 |
| NB | NB | [Master data change initiated by the NB (responsible)](/en/prozessdoku/202604/NB/GPKE-Teil4-stammdatenaenderung-vom-nb-verantwortlich-ausgehend) | GPKE part 4 | Electricity | Step 3 |
| NB | NB | [Master data change initiated by the NB (responsible)](/en/prozessdoku/202604/NB/GPKE-Teil4-stammdatenaenderung-vom-nb-verantwortlich-ausgehend) | GPKE part 4 | Electricity | Step 6 |
| NB | NB | [Master data change initiated by the NB (responsible)](/en/prozessdoku/202604/NB/GPKE-Teil4-stammdatenaenderung-vom-nb-verantwortlich-ausgehend) | GPKE part 4 | Electricity | Step 10 |
| MSB | MSB | [Order placement for a master data change to the LF (responsible)](/en/prozessdoku/202604/MSB/GPKE-Teil4-bestellung-zur-stammdatenaenderung-an-lf-verantwortlich) | GPKE part 4 | Electricity | Step 2 |
| MSB | MSB | [Order placement for a master data change to the LF (responsible)](/en/prozessdoku/202604/MSB/GPKE-Teil4-bestellung-zur-stammdatenaenderung-an-lf-verantwortlich) | GPKE part 4 | Electricity | Step 4 |
| MSB | MSB | [Order placement for a master data change to the MSB (responsible)](/en/prozessdoku/202604/MSB/GPKE-Teil4-bestellung-zur-stammdatenaenderung-an-msb-verantwortlich) | GPKE part 4 | Electricity | Step 2 |
| MSB | MSB | [Order placement for a master data change to the MSB (responsible)](/en/prozessdoku/202604/MSB/GPKE-Teil4-bestellung-zur-stammdatenaenderung-an-msb-verantwortlich) | GPKE part 4 | Electricity | Step 4 |
| MSB | MSB | [Order placement for a master data change to the MSB (responsible)](/en/prozessdoku/202604/MSB/GPKE-Teil4-bestellung-zur-stammdatenaenderung-an-msb-verantwortlich) | GPKE part 4 | Electricity | Step 6 |
| MSB | MSB | [Order placement for a master data change to the MSB (responsible)](/en/prozessdoku/202604/MSB/GPKE-Teil4-bestellung-zur-stammdatenaenderung-an-msb-verantwortlich) | GPKE part 4 | Electricity | Step 8 |
| MSB | MSB | [Order placement for a master data change to the NB (responsible)](/en/prozessdoku/202604/MSB/GPKE-Teil4-bestellung-zur-stammdatenaenderung-an-nb-verantwortlich) | GPKE part 4 | Electricity | Step 2 |
| MSB | MSB | [Order placement for a master data change to the NB (responsible)](/en/prozessdoku/202604/MSB/GPKE-Teil4-bestellung-zur-stammdatenaenderung-an-nb-verantwortlich) | GPKE part 4 | Electricity | Step 4 |
| MSB | MSB | [Order placement for a master data change to the NB (responsible)](/en/prozessdoku/202604/MSB/GPKE-Teil4-bestellung-zur-stammdatenaenderung-an-nb-verantwortlich) | GPKE part 4 | Electricity | Step 6 |
| MSB | MSB | [Master data change initiated by the LF (responsible)](/en/prozessdoku/202604/MSB/GPKE-Teil4-stammdatenaenderung-vom-lf-verantwortlich-ausgehend) | GPKE part 4 | Electricity | Step 3 |
| MSB | MSB | [Master data change initiated by the LF (responsible)](/en/prozessdoku/202604/MSB/GPKE-Teil4-stammdatenaenderung-vom-lf-verantwortlich-ausgehend) | GPKE part 4 | Electricity | Step 6 |
| MSB | MSB | [Master data change initiated by the MSB (responsible)](/en/prozessdoku/202604/MSB/GPKE-Teil4-stammdatenaenderung-vom-msb-verantwortlich-ausgehend) | GPKE part 4 | Electricity | Step 3 |
| MSB | MSB | [Master data change initiated by the MSB (responsible)](/en/prozessdoku/202604/MSB/GPKE-Teil4-stammdatenaenderung-vom-msb-verantwortlich-ausgehend) | GPKE part 4 | Electricity | Step 6 |
| MSB | MSB | [Master data change initiated by the MSB (responsible)](/en/prozessdoku/202604/MSB/GPKE-Teil4-stammdatenaenderung-vom-msb-verantwortlich-ausgehend) | GPKE part 4 | Electricity | Step 9 |
| MSB | MSB | [Master data change initiated by the MSB (responsible)](/en/prozessdoku/202604/MSB/GPKE-Teil4-stammdatenaenderung-vom-msb-verantwortlich-ausgehend) | GPKE part 4 | Electricity | Step 13 |
| MSB | MSB | [Master data change initiated by the NB (responsible)](/en/prozessdoku/202604/MSB/GPKE-Teil4-stammdatenaenderung-vom-nb-verantwortlich-ausgehend) | GPKE part 4 | Electricity | Step 3 |
| MSB | MSB | [Master data change initiated by the NB (responsible)](/en/prozessdoku/202604/MSB/GPKE-Teil4-stammdatenaenderung-vom-nb-verantwortlich-ausgehend) | GPKE part 4 | Electricity | Step 6 |
| MSB | MSB | [Master data change initiated by the NB (responsible)](/en/prozessdoku/202604/MSB/GPKE-Teil4-stammdatenaenderung-vom-nb-verantwortlich-ausgehend) | GPKE part 4 | Electricity | Step 10 |
| MSB | WMSB | [Order placement for a master data change to the MSB (responsible)](/en/prozessdoku/202604/MSB--WMSB/GPKE-Teil4-bestellung-zur-stammdatenaenderung-an-msb-verantwortlich) | GPKE part 4 | Electricity | Step 2 |
| MSB | WMSB | [Order placement for a master data change to the MSB (responsible)](/en/prozessdoku/202604/MSB--WMSB/GPKE-Teil4-bestellung-zur-stammdatenaenderung-an-msb-verantwortlich) | GPKE part 4 | Electricity | Step 4 |
| MSB | WMSB | [Order placement for a master data change to the MSB (responsible)](/en/prozessdoku/202604/MSB--WMSB/GPKE-Teil4-bestellung-zur-stammdatenaenderung-an-msb-verantwortlich) | GPKE part 4 | Electricity | Step 6 |
| MSB | WMSB | [Order placement for a master data change to the MSB (responsible)](/en/prozessdoku/202604/MSB--WMSB/GPKE-Teil4-bestellung-zur-stammdatenaenderung-an-msb-verantwortlich) | GPKE part 4 | Electricity | Step 8 |
| MSB | WMSB | [Master data change initiated by the MSB (responsible)](/en/prozessdoku/202604/MSB--WMSB/GPKE-Teil4-stammdatenaenderung-vom-msb-verantwortlich-ausgehend) | GPKE part 4 | Electricity | Step 3 |
| MSB | WMSB | [Master data change initiated by the MSB (responsible)](/en/prozessdoku/202604/MSB--WMSB/GPKE-Teil4-stammdatenaenderung-vom-msb-verantwortlich-ausgehend) | GPKE part 4 | Electricity | Step 6 |
| MSB | WMSB | [Master data change initiated by the MSB (responsible)](/en/prozessdoku/202604/MSB--WMSB/GPKE-Teil4-stammdatenaenderung-vom-msb-verantwortlich-ausgehend) | GPKE part 4 | Electricity | Step 9 |
| MSB | WMSB | [Master data change initiated by the MSB (responsible)](/en/prozessdoku/202604/MSB--WMSB/GPKE-Teil4-stammdatenaenderung-vom-msb-verantwortlich-ausgehend) | GPKE part 4 | Electricity | Step 13 |
| ÜNB | ÜNB | [Billing data for balancing group settlement](/en/prozessdoku/202604/UENB/GPKE-Teil2-abrechnungsdaten-bilanzkreisabrechnung) | GPKE part 2 | Electricity | Step 3 |
| ÜNB | ÜNB | [Billing data for balancing group settlement](/en/prozessdoku/202604/UENB/GPKE-Teil2-abrechnungsdaten-bilanzkreisabrechnung) | GPKE part 2 | Electricity | Step 6 |
| ÜNB | ÜNB | [Order placement for a change of billing data for balancing group settlement from ÜNB to NB](/en/prozessdoku/202604/UENB/GPKE-Teil2-bestellung-einer-aenderung-von-abrechnungsdaten-zur-bilanzkreisabrechnung-von-uenb-an-nb) | GPKE part 2 | Electricity | Step 2 |
| ÜNB | ÜNB | [Order placement for a master data change to the LF (responsible)](/en/prozessdoku/202604/UENB/GPKE-Teil4-bestellung-zur-stammdatenaenderung-an-lf-verantwortlich) | GPKE part 4 | Electricity | Step 2 |
| ÜNB | ÜNB | [Order placement for a master data change to the LF (responsible)](/en/prozessdoku/202604/UENB/GPKE-Teil4-bestellung-zur-stammdatenaenderung-an-lf-verantwortlich) | GPKE part 4 | Electricity | Step 4 |
| ÜNB | ÜNB | [Order placement for a master data change to the MSB (responsible)](/en/prozessdoku/202604/UENB/GPKE-Teil4-bestellung-zur-stammdatenaenderung-an-msb-verantwortlich) | GPKE part 4 | Electricity | Step 2 |
| ÜNB | ÜNB | [Order placement for a master data change to the MSB (responsible)](/en/prozessdoku/202604/UENB/GPKE-Teil4-bestellung-zur-stammdatenaenderung-an-msb-verantwortlich) | GPKE part 4 | Electricity | Step 4 |
| ÜNB | ÜNB | [Order placement for a master data change to the MSB (responsible)](/en/prozessdoku/202604/UENB/GPKE-Teil4-bestellung-zur-stammdatenaenderung-an-msb-verantwortlich) | GPKE part 4 | Electricity | Step 6 |
| ÜNB | ÜNB | [Order placement for a master data change to the MSB (responsible)](/en/prozessdoku/202604/UENB/GPKE-Teil4-bestellung-zur-stammdatenaenderung-an-msb-verantwortlich) | GPKE part 4 | Electricity | Step 8 |
| ÜNB | ÜNB | [Order placement for a master data change to the NB (responsible)](/en/prozessdoku/202604/UENB/GPKE-Teil4-bestellung-zur-stammdatenaenderung-an-nb-verantwortlich) | GPKE part 4 | Electricity | Step 2 |
| ÜNB | ÜNB | [Order placement for a master data change to the NB (responsible)](/en/prozessdoku/202604/UENB/GPKE-Teil4-bestellung-zur-stammdatenaenderung-an-nb-verantwortlich) | GPKE part 4 | Electricity | Step 4 |
| ÜNB | ÜNB | [Order placement for a master data change to the NB (responsible)](/en/prozessdoku/202604/UENB/GPKE-Teil4-bestellung-zur-stammdatenaenderung-an-nb-verantwortlich) | GPKE part 4 | Electricity | Step 6 |
| ÜNB | ÜNB | [Master data on balancing group integrity](/en/prozessdoku/202604/UENB/GPKE-Teil4-stammdaten-zur-bilanzkreistreue) | GPKE part 4 | Electricity | Step 3 |
| ÜNB | ÜNB | [Master data change initiated by the LF (responsible)](/en/prozessdoku/202604/UENB/GPKE-Teil4-stammdatenaenderung-vom-lf-verantwortlich-ausgehend) | GPKE part 4 | Electricity | Step 3 |
| ÜNB | ÜNB | [Master data change initiated by the LF (responsible)](/en/prozessdoku/202604/UENB/GPKE-Teil4-stammdatenaenderung-vom-lf-verantwortlich-ausgehend) | GPKE part 4 | Electricity | Step 6 |
| ÜNB | ÜNB | [Master data change initiated by the MSB (responsible)](/en/prozessdoku/202604/UENB/GPKE-Teil4-stammdatenaenderung-vom-msb-verantwortlich-ausgehend) | GPKE part 4 | Electricity | Step 3 |
| ÜNB | ÜNB | [Master data change initiated by the MSB (responsible)](/en/prozessdoku/202604/UENB/GPKE-Teil4-stammdatenaenderung-vom-msb-verantwortlich-ausgehend) | GPKE part 4 | Electricity | Step 6 |
| ÜNB | ÜNB | [Master data change initiated by the MSB (responsible)](/en/prozessdoku/202604/UENB/GPKE-Teil4-stammdatenaenderung-vom-msb-verantwortlich-ausgehend) | GPKE part 4 | Electricity | Step 9 |
| ÜNB | ÜNB | [Master data change initiated by the MSB (responsible)](/en/prozessdoku/202604/UENB/GPKE-Teil4-stammdatenaenderung-vom-msb-verantwortlich-ausgehend) | GPKE part 4 | Electricity | Step 13 |
| ÜNB | ÜNB | [Master data change initiated by the NB (responsible)](/en/prozessdoku/202604/UENB/GPKE-Teil4-stammdatenaenderung-vom-nb-verantwortlich-ausgehend) | GPKE part 4 | Electricity | Step 3 |
| ÜNB | ÜNB | [Master data change initiated by the NB (responsible)](/en/prozessdoku/202604/UENB/GPKE-Teil4-stammdatenaenderung-vom-nb-verantwortlich-ausgehend) | GPKE part 4 | Electricity | Step 6 |
| ÜNB | ÜNB | [Master data change initiated by the NB (responsible)](/en/prozessdoku/202604/UENB/GPKE-Teil4-stammdatenaenderung-vom-nb-verantwortlich-ausgehend) | GPKE part 4 | Electricity | Step 10 |

</div>

## Business classification

<div className="maco-tabellenrahmen">

| Attribute | Value |
|---|---|
| Use case (AHB) | Processing status message |
| AHB | IFTSTA AHB |
| Response to check identifier | [55156](/schnittstellen/202604/pruefi/UTILMD/PI_55156) · [55220](/schnittstellen/202604/pruefi/UTILMD/PI_55220) · [55673](/schnittstellen/202604/pruefi/UTILMD/PI_55673) |
| Decision tree | [E_0620](/referenz/202604/ebd/E_0620) · [E_0619](/referenz/202604/ebd/E_0619) · [E_0618](/referenz/202604/ebd/E_0618) · [E_0595](/referenz/202604/ebd/E_0595) · [E_0613](/referenz/202604/ebd/E_0613) · [E_0626](/referenz/202604/ebd/E_0626) · [E_0627](/referenz/202604/ebd/E_0627) · [E_0628](/referenz/202604/ebd/E_0628) · [E_0629](/referenz/202604/ebd/E_0629) · [E_0630](/referenz/202604/ebd/E_0630) · [E_0632](/referenz/202604/ebd/E_0632) · [E_0633](/referenz/202604/ebd/E_0633) · [E_0634](/referenz/202604/ebd/E_0634) · [E_0635](/referenz/202604/ebd/E_0635) · [E_0573](/referenz/202604/ebd/E_0573) · [E_0576](/referenz/202604/ebd/E_0576) · [E_0577](/referenz/202604/ebd/E_0577) · [E_0588](/referenz/202604/ebd/E_0588) · [E_0589](/referenz/202604/ebd/E_0589) · [E_0586](/referenz/202604/ebd/E_0586) · [E_0585](/referenz/202604/ebd/E_0585) · [E_0584](/referenz/202604/ebd/E_0584) · [E_0587](/referenz/202604/ebd/E_0587) · [E_0616](/referenz/202604/ebd/E_0616) |
| Transmission channel | AS4 |

</div>

:::caution{title="This check identifier is used in 24 contexts"}

Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.

:::

<div className="maco-tabellenrahmen">

| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| GPKE part 2 | Billing data grid usage settlement | NB → LF | Processing status of the response message |
| GPKE part 2 | Billing data balancing group settlement | NB → LF | Processing status of the response message |
| GPKE part 2 | Billing data balancing group settlement | NB → ÜNB | Processing status of the response message |
| GPKE part 2 | Order placement for a change of billing data from LF to NB | NB → LF | Processing status of the order placement |
| GPKE part 2 | Order placement for a change of billing data for the balancing group settlement from ÜNB to NB | NB → ÜNB | Processing status of the order placement |
| GPKE part 4 | Master data change initiated by the NB (responsible) | NB → LF | Processing status of the response message |
| GPKE part 4 | Master data change initiated by the NB (responsible) | NB → MSB | Processing status of the response message |
| GPKE part 4 | Master data change initiated by the NB (responsible) | NB → ÜNB | Processing status of the response message |
| GPKE part 4 | Master data change initiated by the LF (responsible) | LF → NB | Processing status of the response message |
| GPKE part 4 | Master data change initiated by the LF (responsible) | LF → MSB | Processing status of the response message |
| GPKE part 4 | Master data change initiated by the MSB (responsible) | MSB → NB | Processing status of the response message |
| GPKE part 4 | Master data change initiated by the MSB (responsible) | MSB → LF | Processing status of the response message |
| GPKE part 4 | Master data change initiated by the MSB (responsible) | MSB → further MSB | Processing status of the response message |
| GPKE part 4 | Master data change initiated by the MSB (responsible) | MSB → ÜNB | Processing status of the response message |
| GPKE part 4 | Order placement for master data change to NB (responsible) | NB → LF | Processing status of the order placement |
| GPKE part 4 | Order placement for master data change to NB (responsible) | NB → MSB | Processing status of the order placement |
| GPKE part 4 | Order placement for master data change to NB (responsible) | NB → ÜNB | Processing status of the order placement |
| GPKE part 4 | Order placement for master data change to LF (responsible) | LF → NB | Processing status of the order placement |
| GPKE part 4 | Order placement for master data change to LF (responsible) | LF → MSB | Processing status of the order placement |
| GPKE part 4 | Order placement for master data change to MSB (responsible) | MSB → NB | Processing status of the order placement |
| GPKE part 4 | Order placement for master data change to MSB (responsible) | MSB → LF | Processing status of the order placement |
| GPKE part 4 | Order placement for master data change to MSB (responsible) | MSB → further MSB | Processing status of the order placement |
| GPKE part 4 | Order placement for master data change to MSB (responsible) | MSB → ÜNB | Processing status of the order placement |
| GPKE part 4 | Master data on balancing group integrity | NB → ÜNB | Processing status of the response message |

</div>

:::caution{title="One entry from format version 202610"}

The check identifiers table of format version 202604 does not carry this entry: **decision tree**. It comes from version 202610. Everything else on this page — use case, rulebook and communication direction — comes from its own version. Before adopting this into an implementation specification, check whether what is stated applies to 202604.

:::

## Transaction and responses

**Role of this check identifier: status message.** This IFTSTA message carries a status field (`antwortstatus` and `antwortstatusCodeliste`), but its title names neither “response” nor a polarity. It is therefore recorded as a **status message** and not as a response in the sense of a decision tree.

### Which request this message responds to

<div className="maco-tabellenrahmen">

| Role | Check identifier | Use case | Message type | Origin of supply |
|---|---|---|---|---|
| Request | [55156](/schnittstellen/202604/pruefi/UTILMD/PI_55156) | Response message/request settl. data BG settl. cons. MaLo | UTILMD | explicit |
| Request | [55220](/schnittstellen/202604/pruefi/UTILMD/PI_55220) | Response message/request settl. data NNA | UTILMD | explicit |
| Request | [55673](/schnittstellen/202604/pruefi/UTILMD/PI_55673) | Response message/request settl. data BG settl. gen. Malo | UTILMD | explicit |

</div>

### In which field the request is quoted

<div className="maco-tabellenrahmen">

| Reference field of this message | EDIFACT segment | Target field in the request |
|---|---|---|
| `vorgangsreferenznummer` | `SG14.CNI.SG15.STS+Z43.RFF+ACW` | — |

</div>

RFF+ACW names the "preceding message". Which field is meant there is not carried by the source — the target remains open.

### Response codes

**Decision trees:** [E_0573](/en/referenz/202604/ebd/E_0573) · [E_0576](/en/referenz/202604/ebd/E_0576) · [E_0577](/en/referenz/202604/ebd/E_0577) · [E_0584](/en/referenz/202604/ebd/E_0584) · [E_0585](/en/referenz/202604/ebd/E_0585) · [E_0586](/en/referenz/202604/ebd/E_0586) · [E_0587](/en/referenz/202604/ebd/E_0587) · [E_0588](/en/referenz/202604/ebd/E_0588) · [E_0589](/en/referenz/202604/ebd/E_0589) · [E_0595](/en/referenz/202604/ebd/E_0595) · [E_0613](/en/referenz/202604/ebd/E_0613) · [E_0616](/en/referenz/202604/ebd/E_0616) · [E_0618](/en/referenz/202604/ebd/E_0618) · [E_0619](/en/referenz/202604/ebd/E_0619) · [E_0620](/en/referenz/202604/ebd/E_0620) · [E_0626](/en/referenz/202604/ebd/E_0626) · [E_0627](/en/referenz/202604/ebd/E_0627) · [E_0628](/en/referenz/202604/ebd/E_0628) · [E_0629](/en/referenz/202604/ebd/E_0629) · [E_0630](/en/referenz/202604/ebd/E_0630) · [E_0632](/en/referenz/202604/ebd/E_0632) · [E_0633](/en/referenz/202604/ebd/E_0633) · [E_0634](/en/referenz/202604/ebd/E_0634) · [E_0635](/en/referenz/202604/ebd/E_0635).

The handbook names **24 decision trees** for this check identifier. Their result codes are not given here but on the page of each tree — together they would run to several hundred rows, and the information would be lost among them.

**Check identifiers of the same AHB table:** No other check identifier of message type IFTSTA has the same row structure in this version.

<Hinweisbereich>

An **\*** after a field or group name marks a **mandatory field** or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.

The status column carries two vocabularies because the manual answers two questions: on a **group row**, *Muss*, *Soll* or *Kann* states whether the EDIFACT segment must be present; on a **field row**, *X* states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.

For this check identifier, the application handbook lists **79 rows**. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.

The **Condition** column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.

The test data contains one transaction for this check identifier under the message type `iftsta`. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.

:::note{title="Placeholder from the test data set"}

The test data set carries placeholders instead of valid values: `{{date}}` and `{{time}}` in the UNB interchange envelope of every EDIFACT file. **The page replaces these on call with the current date and the current time** — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.

`<businessKey>` stays in place. It is not a time value, and an invented key would look like a valid one.

:::

</Hinweisbereich>