# Check identifier 13009 — Energy quantity (Gas)

<span hidden data-pagefind-meta={"title:Check identifier 13009 — Energy quantity (gas) · MSCONS · Format version 202604"} />

Check identifier **13009** · EDIFACT message type **MSCONS** · Format version **202604**

## Data structure

<Handbuchsatz>

<div className="maco-tabellenrahmen">

| Structure (BO4E) | Description | Format | <span className="hbs-p" title="Energiemenge (Gas)">13009</span> | Condition |
|---|---|---|---|---|
| <span className="hbs-g hbs-e0">**stammdaten** <span className="hbs-pflicht">\*</span></span> | — | object | Must | — |
| <span className="hbs-g hbs-e1">**ENERGIEMENGE** <span className="hbs-liste">[ ]</span> <span className="hbs-pflicht">\*</span></span> | — | object[] | Must | — |
| <span className="hbs-f hbs-e2">[konfiguration](/en/bo4e/202604/bo/Energiemenge#konfiguration)</span> <AhbTabelle pruefid="13009" format="MSCONS" fv="202604" zeile={60} segment="SG5.NAD+DP.SG6.LOC+172" /><span className="hbs-nr">00010</span> | konfiguration | string | X | — |
| <span className="hbs-f hbs-e2">[lokationsId](/en/bo4e/202604/bo/Energiemenge#lokationsid) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13009" format="MSCONS" fv="202604" zeile={60} segment="SG5.NAD+DP.SG6.LOC+172" /><span className="hbs-nr">00020</span> | Unique number of the market location or of the metering location to which the energy quantity belongs | string | X | — |
| <span className="hbs-g hbs-e2">**energieverbrauch** <span className="hbs-liste">[ ]</span> <span className="hbs-pflicht">\*</span></span> | — | object[] | Must | — |
| <span className="hbs-f hbs-e3">[enddatum](/en/bo4e/202604/com/Verbrauch#enddatum)</span> <AhbTabelle pruefid="13009" format="MSCONS" fv="202604" zeile={79} segment="SG5.NAD+DP.SG6.LOC+172.SG9.LIN.SG10.QTY.DTM+164" /><span className="hbs-nr">00030</span> | enddatum | string (date-time) | X | — |
| <span className="hbs-f hbs-e3">[leistungsperiode](/en/bo4e/202604/com/Verbrauch#leistungsperiode)</span> <AhbTabelle pruefid="13009" format="MSCONS" fv="202604" zeile={83} segment="SG5.NAD+DP.SG6.LOC+172.SG9.LIN.SG10.QTY.DTM+306" /><span className="hbs-nr">00040</span> | leistungsperiode | string | X | — |
| <span className="hbs-f hbs-e3">[messwertstatus](/en/bo4e/202604/com/Verbrauch#messwertstatus) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13009" format="MSCONS" fv="202604" zeile={68} segment="SG5.NAD+DP.SG6.LOC+172.SG9.LIN.SG10.QTY" /><span className="hbs-nr">00050</span> | The status of a meter reading | [Enum Messwertstatus](/en/bo4e/202604/enum/Messwertstatus) | Must | — |
| <span className="hbs-w hbs-e4">`ABGELESEN`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`ERSATZWERT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`VORSCHLAGSWERT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`NICHT_VERWENDBAR`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`PROGNOSEWERT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`ENERGIEMENGESUMMIERT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`VOLAEUFIGERWERT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`FEHLT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`ANGABE_FUER_LIEFERSCHEIN`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`GRUNDLAGE_POG_ERMITTLUNG`</span> | — | — | Must | — |
| <span className="hbs-f hbs-e3">[obiskennzahl](/en/bo4e/202604/com/Verbrauch#obiskennzahl) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13009" format="MSCONS" fv="202604" zeile={65} segment="SG5.NAD+DP.SG6.LOC+172.SG9.LIN.PIA+5" /><span className="hbs-nr">00060</span> | obiskennzahl | string | X | — |
| <span className="hbs-f hbs-e3">[position](/en/bo4e/202604/com/Verbrauch#position) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13009" format="MSCONS" fv="202604" zeile={62} segment="SG5.NAD+DP.SG6.LOC+172.SG9.LIN" /><span className="hbs-nr">00070</span> | position | integer | Must | — |
| <span className="hbs-f hbs-e3">[startdatum](/en/bo4e/202604/com/Verbrauch#startdatum)</span> <AhbTabelle pruefid="13009" format="MSCONS" fv="202604" zeile={75} segment="SG5.NAD+DP.SG6.LOC+172.SG9.LIN.SG10.QTY.DTM+163" /><span className="hbs-nr">00080</span> | startdatum | string (date-time) | X | — |
| <span className="hbs-f hbs-e3">[wert](/en/bo4e/202604/com/Verbrauch#wert) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13009" format="MSCONS" fv="202604" zeile={68} segment="SG5.NAD+DP.SG6.LOC+172.SG9.LIN.SG10.QTY" /><span className="hbs-nr">00090</span> | wert | number (float) | Must | — |
| <span className="hbs-g hbs-e3">**statuszusatzinformationen** <span className="hbs-liste">[ ]</span></span> | — | object[] | May | — |
| <span className="hbs-f hbs-e4">[art](/en/bo4e/202604/com/StatusZusatzInformation#art)</span> <AhbTabelle pruefid="13009" format="MSCONS" fv="202604" zeile={159} segment="SG5.NAD+DP.SG6.LOC+172.SG9.LIN.SG10.QTY.STS+Z31" /><span className="hbs-nr">00100</span> | Status type | [Enum StatusArt](/en/bo4e/202604/enum/StatusArt) | X | — |
| <span className="hbs-w hbs-e5">`PLAUSIBILISIERUNGSHINWEIS`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`ERSATZWERTBILDUNGSVERFAHREN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`KORREKTURGRUND`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`GRUND_ERSATZWERTBILDUNGSVERFAHREN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`GASQUALITAET`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`MESSKLASSIFIZIERUNG`</span> | — | — | X | — |
| <span className="hbs-f hbs-e4">[status](/en/bo4e/202604/com/StatusZusatzInformation#status)</span> <AhbTabelle pruefid="13009" format="MSCONS" fv="202604" zeile={159} segment="SG5.NAD+DP.SG6.LOC+172.SG9.LIN.SG10.QTY.STS+Z31" /><span className="hbs-nr">00110</span> | Status | [Enum Status](/en/bo4e/202604/enum/Status) | X | — |
| <span className="hbs-w hbs-e5">`KUNDENSELBSTABLESUNG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`LEERSTAND`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`REALER_ZAEHLERUEBERLAUF_GEPRUEFT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`PLAUSIBEL_WG_KONTROLLABLESUNG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`PLAUSIBEL_WG_KUNDENHINWEIS`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`AUSTAUSCH_DES_ERSATZWERTES`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`RECHENWERT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`BASIS_MME`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`VERGLEICHSMESSUNG_GEEICHT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`VERGLEICHSMESSUNG_NICHT_GEEICHT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`MESSWERTNACHBILDUNG_AUS_GEEICHTEN_WERTEN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`MESSWERTNACHBILDUNG_AUS_NICHT_GEEICHTEN_WERTEN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`INTERPOLATION`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`HALTEWERT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`BILANZIERUNG_NETZABSCHNITT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`HISTORISCHE_MESSWERTE`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`STATISTISCHE_METHODE`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`AUFTEILUNG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`VERWENDUNG_VON_WERTEN_DES_STOERMENGENZAEHLWERKS`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`UMGANGS_UND_KORREKTURMENGEN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`ANGABEN_MESSLOKATION`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`KEIN_ZUGANG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`KOMMUNIKATIONSSTOERUNG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`NETZAUSFALL`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`SPANNUNGSAUSFALL`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`STATUS_GERAETEWECHSEL`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`KALIBRIERUNG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`GERAET_ARBEITET_AUSSERHALB_DER_BETRIEBSBEDINGUNGEN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`MESSEINRICHTUNG_GESTOERT_DEFEKT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`UNSICHERHEIT_MESSUNG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`BERUECKSICHTIGUNG_STOERMENGENZAEHLWERK`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`MENGENUMWERTUNG_VOLLSTAENDIG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`UHRZEIT_GESTELLT_SYNCHRONISATION`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`MESSWERT_UNPLAUSIBEL`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`FALSCHER_WANDLERFAKTOR`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`FEHLERHAFTE_ABLESUNG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`AENDERUNG_DER_BERECHNUNG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`UMBAU_DER_MESSLOKATION`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`DATENBEARBEITUNGSFEHLER`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`BRENNWERTKORREKTUR`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`Z_ZAHL_KORREKTUR`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`STOERUNG_DEFEKT_MESSEINRICHTUNG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`AENDERUNG_TARIFSCHALTZEITEN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`TARIFSCHALTGERAET_DEFEKT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`IMPULSWERTIGKEIT_NICHT_AUSREICHEND`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`ENERGIEMENGE_IN_UNGEMESSENEM_ZEITINTERVALL`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`ENERGIEMENGE_AUS_DEM_UNGEPAIRTEN_ZEITINTERVALL`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`WARTUNGSARBEITEN_AN_GEEICHTEM_MESSGERAET`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`GESTOERTE_WERTE`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`WARTUNGSARBEITEN_AN_EICHRECHTSKONFORMEN_MESSGERAETEN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`KONSISTENZ_UND_SYNCHRONPRUEFUNG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`GRUND_ANGABEN_MESSLOKATION`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`ANFORDERUNG_IN_DIE_VERGANGENHEIT_ZUM_ANGEFORDERTEN_ZEITPUNKT_LIEGT_KEIN_WERT_VOR`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`UMSTELLUNG_GASQUALITAET`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`ZAEHLERSTAND_ZUM_BEGINN_DER_ANGEGEBENEN_ENERGIEMENGE_VORHANDEN_UND_KOMMUNIZIERT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`ZAEHLERSTAND_ZUM_ENDE_DER_ANGEGEBENEN_ENERGIEMENGE_VORHANDEN_UND_KOMMUNIZIERT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`ZAEHLERSTAND_ZUM_BEGINN_DER_ANGEGEBENEN_ENERGIEMENGE_NICHT_VORHANDEN_DA_MENGENABGRENZUNG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`ZAEHLERSTAND_ZUM_ENDE_DER_ANGEGEBENEN_ENERGIEMENGE_NICHT_VORHANDEN_DA_MENGENABGRENZUNG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`GESCHEITERT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`AUSGEBAUT`</span> | — | — | X | — |
| <span className="hbs-g hbs-e0">**transaktionsdaten** <span className="hbs-pflicht">\*</span></span> | — | object | Must | — |
| <span className="hbs-f hbs-e1">[anfrageReferenz](/en/bo4e/202604/cdoc/Transaktionsdaten#anfragereferenz)</span> <AhbTabelle pruefid="13009" format="MSCONS" fv="202604" zeile={30} segment="SG1.RFF+AGI" /><span className="hbs-nr">00120</span> | Application number / RFF+AGI | string | X | — |
| <span className="hbs-f hbs-e1">[dokumentennummer](/en/bo4e/202604/cdoc/Transaktionsdaten#dokumentennummer) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13009" format="MSCONS" fv="202604" zeile={20} segment="BGM" /><span className="hbs-nr">00130</span> | EDIFACT reference from the BGM segment / BGM | string | Must | — |
| <span className="hbs-f hbs-e1">[kategorie](/en/bo4e/202604/cdoc/Transaktionsdaten#kategorie) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13009" format="MSCONS" fv="202604" zeile={20} segment="BGM" /><span className="hbs-nr">00140</span> | Qualifier from the beginning of the EDIFACT message / BGM | string | Must | — |
| <span className="hbs-f hbs-e1">[nachrichtendatum](/en/bo4e/202604/cdoc/Transaktionsdaten#nachrichtendatum) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13009" format="MSCONS" fv="202604" zeile={26} segment="DTM+137" /><span className="hbs-nr">00150</span> | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| <span className="hbs-f hbs-e1">[nachrichtenfunktion](/en/bo4e/202604/cdoc/Transaktionsdaten#nachrichtenfunktion) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13009" format="MSCONS" fv="202604" zeile={20} segment="BGM" /><span className="hbs-nr">00160</span> | Message function code / BGM | string | Must | — |
| <span className="hbs-f hbs-e1">[nachrichtenreferenznummer](/en/bo4e/202604/cdoc/Transaktionsdaten#nachrichtenreferenznummer) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13009" format="MSCONS" fv="202604" zeile={13} segment="UNH" /><span className="hbs-nr">00170</span> | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| <span className="hbs-f hbs-e1">[pruefidentifikator](/en/bo4e/202604/cdoc/Transaktionsdaten#pruefidentifikator) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13009" format="MSCONS" fv="202604" zeile={33} segment="SG1.RFF+Z13" /><span className="hbs-nr">00180</span> | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| <span className="hbs-g hbs-e1">**absender** <span className="hbs-pflicht">\*</span></span> | — | object | Must | — |
| <span className="hbs-f hbs-e2">[rollencodenummer](/en/bo4e/202604/bo/Marktteilnehmer#rollencodenummer) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13009" format="MSCONS" fv="202604" zeile={36} segment="SG2.NAD+MS" /><span className="hbs-nr">00190</span> | Specifies the code value of the market role. | string | X | — |
| <span className="hbs-f hbs-e2">[rollencodetyp](/en/bo4e/202604/bo/Marktteilnehmer#rollencodetyp) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13009" format="MSCONS" fv="202604" zeile={36} segment="SG2.NAD+MS" /><span className="hbs-nr">00200</span> | Indicates the type of the code. | [Enum Rollencodetyp](/en/bo4e/202604/enum/Rollencodetyp) | X | — |
| <span className="hbs-w hbs-e3">`BDEW`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`GS1`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`GLN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`DVGW`</span> | — | — | X | — |
| <span className="hbs-g hbs-e2">**ansprechpartner**</span> | — | object | May | — |
| <span className="hbs-f hbs-e3">[eMailAdresse](/en/bo4e/202604/bo/Ansprechpartner#emailadresse)</span> <AhbTabelle pruefid="13009" format="MSCONS" fv="202604" zeile={43} segment="SG2.NAD+MS.SG4.CTA+IC.COM+[EM\|FX\|TE\|AJ\|AL]" /><span className="hbs-nr">00210</span> | Email address | string | Must | — |
| <span className="hbs-f hbs-e3">[nachname](/en/bo4e/202604/bo/Ansprechpartner#nachname)</span> <AhbTabelle pruefid="13009" format="MSCONS" fv="202604" zeile={41} segment="SG2.NAD+MS.SG4.CTA+IC" /><span className="hbs-nr">00220</span> | Surname (family name) of the contact person | string | X | — |
| <span className="hbs-g hbs-e3">**rufnummern** <span className="hbs-liste">[ ]</span></span> | — | object[] | May | — |
| <span className="hbs-f hbs-e4">[nummerntyp](/en/bo4e/202604/com/Rufnummer#nummerntyp)</span> <AhbTabelle pruefid="13009" format="MSCONS" fv="202604" zeile={43} segment="SG2.NAD+MS.SG4.CTA+IC.COM+[EM\|FX\|TE\|AJ\|AL]" /><span className="hbs-nr">00230</span> | Phone number type | [Enum Rufnummernart](/en/bo4e/202604/enum/Rufnummernart) | Must | — |
| <span className="hbs-w hbs-e5">`RUF_ZENTRALE`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`FAX_ZENTRALE`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`SAMMELRUF`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`SAMMELFAX`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`ABTEILUNGRUF`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`ABTEILUNGFAX`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`RUF_DURCHWAHL`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`FAX_DURCHWAHL`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`MOBIL_NUMMER`</span> | — | — | Must | — |
| <span className="hbs-f hbs-e4">[rufnummer](/en/bo4e/202604/com/Rufnummer#rufnummer)</span> <AhbTabelle pruefid="13009" format="MSCONS" fv="202604" zeile={43} segment="SG2.NAD+MS.SG4.CTA+IC.COM+[EM\|FX\|TE\|AJ\|AL]" /><span className="hbs-nr">00240</span> | rufnummer | string | Must | — |
| <span className="hbs-g hbs-e1">**empfaenger** <span className="hbs-pflicht">\*</span></span> | — | object | Must | — |
| <span className="hbs-f hbs-e2">[rollencodenummer](/en/bo4e/202604/bo/Marktteilnehmer#rollencodenummer) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13009" format="MSCONS" fv="202604" zeile={51} segment="SG2.NAD+MR" /><span className="hbs-nr">00250</span> | Specifies the code value of the market role. | string | X | — |
| <span className="hbs-f hbs-e2">[rollencodetyp](/en/bo4e/202604/bo/Marktteilnehmer#rollencodetyp) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13009" format="MSCONS" fv="202604" zeile={51} segment="SG2.NAD+MR" /><span className="hbs-nr">00260</span> | Indicates the type of the code. | [Enum Rollencodetyp](/en/bo4e/202604/enum/Rollencodetyp) | X | — |
| <span className="hbs-w hbs-e3">`BDEW`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`GS1`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`GLN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`DVGW`</span> | — | — | X | — |

</div>

</Handbuchsatz>

## Application handbook (AHB)

<Handbuchsatz>

<div className="maco-tabellenrahmen" data-maco="ahb-tabelle">

| Structure (EDIFACT) | Description | Format | <span className="hbs-p" title="Energiemenge (Gas)">13009</span> | Condition |
|---|---|---|---|---|
| <span className="hbs-g hbs-e0">**UNB**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`0001 UNOC`</span><span className="hbs-nr">00010</span> | UN/ECE character set C | — | X | — |
| <span className="hbs-f hbs-e1">`0002 3`</span><span className="hbs-nr">00020</span> | Version 3 | — | X | — |
| <span className="hbs-f hbs-e1">`0004`</span><span className="hbs-nr">00030</span> | MP-ID Sender | — | X | — |
| <span className="hbs-f hbs-e1">`0007 14`</span><span className="hbs-nr">00040</span> | GS1 | — | X | — |
| <span className="hbs-f hbs-e1">`0007 502`</span><span className="hbs-nr">00050</span> | DE, DVGW Service & Consult GmbH | — | X | — |
| <span className="hbs-f hbs-e1">`0010`</span><span className="hbs-nr">00060</span> | MP-ID recipient | — | X | — |
| <span className="hbs-f hbs-e1">`0007 14`</span><span className="hbs-nr">00070</span> | GS1 | — | X | — |
| <span className="hbs-f hbs-e1">`0007 502`</span><span className="hbs-nr">00080</span> | DE, DVGW Service & Consult GmbH | — | X | — |
| <span className="hbs-f hbs-e1">`0017`</span><span className="hbs-nr">00090</span> | Date of creation | — | X | — |
| <span className="hbs-f hbs-e1">`0019`</span><span className="hbs-nr">00100</span> | Time of creation | — | X | — |
| <span className="hbs-f hbs-e1">`0020`</span><span className="hbs-nr">00110</span> | Interchange control reference | — | X | <span className="hbs-marke">[918]</span> |
| <span className="hbs-f hbs-e1">`0026 EM`</span><span className="hbs-nr">00120</span> | Energy quantity | — | X | — |
| <span className="hbs-g hbs-e0">**UNH**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`0062`</span><span className="hbs-nr">00130</span> | Message reference number | — | X | — |
| <span className="hbs-f hbs-e1">`0065 MSCONS`</span><span className="hbs-nr">00140</span> | Report on the consumption of measurable services | — | X | — |
| <span className="hbs-f hbs-e1">`0052 D`</span><span className="hbs-nr">00150</span> | Draft version | — | X | — |
| <span className="hbs-f hbs-e1">`0054 04B`</span><span className="hbs-nr">00160</span> | Edition 2004 - B | — | X | — |
| <span className="hbs-f hbs-e1">`0051 UN`</span><span className="hbs-nr">00170</span> | UN/CEFACT | — | X | — |
| <span className="hbs-f hbs-e1">`0057 2.4c`</span><span className="hbs-nr">00180</span> | Version number of the underlying BDEW message description | — | X | — |
| <span className="hbs-g hbs-e0">**BGM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1001 7`</span><span className="hbs-nr">00190</span> | Process data report | — | X | — |
| <span className="hbs-f hbs-e1">`1001 Z27`</span><span className="hbs-nr">00200</span> | Transaction data in the calendar year before the start of supply | — | X | — |
| <span className="hbs-f hbs-e1">`1004`</span><span className="hbs-nr">00210</span> | Document number | — | X | — |
| <span className="hbs-f hbs-e1">`1225 9`</span><span className="hbs-nr">00220</span> | Original | — | X | — |
| <span className="hbs-g hbs-e0">**DTM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`2005 137`</span><span className="hbs-nr">00230</span> | Document-/message date/time | — | X | — |
| <span className="hbs-f hbs-e1">`2380`</span><span className="hbs-nr">00240</span> | Date or time or time span, value | — | X | <span className="hbs-marke">[931]</span> <span className="hbs-marke">[494]</span> |
| <span className="hbs-f hbs-e1">`2379 303`</span><span className="hbs-nr">00250</span> | CCYYMMDDHHMMZZZ | — | X | — |
| <span className="hbs-g hbs-e0">**SG1.RFF**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1153 AGI`</span><span className="hbs-nr">00260</span> | Application number | — | X | — |
| <span className="hbs-f hbs-e1">`1154`</span><span className="hbs-nr">00270</span> | Reference number | — | X | <span className="hbs-marke">[529]</span>  ⊻ (<span className="hbs-marke">[531]</span> ∧ <span className="hbs-marke">[509]</span>) |
| <span className="hbs-g hbs-e0">**SG1.RFF**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1153 Z13`</span><span className="hbs-nr">00280</span> | Check identifier | — | X | — |
| <span className="hbs-f hbs-e1">`1154 13009`</span><span className="hbs-nr">00290</span> | Meter reading value energy quantity (gas) | — | X | — |
| <span className="hbs-g hbs-e0">**SG2.NAD**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3035 MS`</span><span className="hbs-nr">00300</span> | Document-/message sender or sender | — | X | — |
| <span className="hbs-f hbs-e1">`3039`</span><span className="hbs-nr">00310</span> | MP-ID | — | X | <span className="hbs-marke">[118]</span> |
| <span className="hbs-f hbs-e1">`3055 9`</span><span className="hbs-nr">00320</span> | GS1 | — | X | — |
| <span className="hbs-f hbs-e1">`3055 332`</span><span className="hbs-nr">00330</span> | DE, DVGW Service & Consult GmbH | — | X | — |
| <span className="hbs-g hbs-e0">**SG4.CTA**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3139 IC`</span><span className="hbs-nr">00340</span> | Information point | — | X | — |
| <span className="hbs-f hbs-e1">`3412`</span><span className="hbs-nr">00350</span> | Department or contact person | — | X | — |
| <span className="hbs-g hbs-e0">**SG4.COM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3148`</span><span className="hbs-nr">00360</span> | Communication address, identification | — | X | ((<span className="hbs-marke">[939]</span> <span className="hbs-marke">[142]</span>) ∨ (<span className="hbs-marke">[940]</span> <span className="hbs-marke">[143]</span>)) ∧ <span className="hbs-marke">[576]</span> |
| <span className="hbs-f hbs-e1">`3155 TE`</span><span className="hbs-nr">00370</span> | Telephone | — | X | <span className="hbs-marke">[1P0..1]</span> |
| <span className="hbs-f hbs-e1">`3155 EM`</span><span className="hbs-nr">00380</span> | Email | — | X | <span className="hbs-marke">[1P0..1]</span> |
| <span className="hbs-f hbs-e1">`3155 AJ`</span><span className="hbs-nr">00390</span> | further telephone | — | X | <span className="hbs-marke">[1P0..1]</span> |
| <span className="hbs-f hbs-e1">`3155 AL`</span><span className="hbs-nr">00400</span> | Mobile phone | — | X | <span className="hbs-marke">[1P0..1]</span> |
| <span className="hbs-f hbs-e1">`3155 FX`</span><span className="hbs-nr">00410</span> | Fax number | — | X | <span className="hbs-marke">[1P0..1]</span> |
| <span className="hbs-g hbs-e0">**SG2.NAD**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3035 MR`</span><span className="hbs-nr">00420</span> | Message recipient | — | X | — |
| <span className="hbs-f hbs-e1">`3039`</span><span className="hbs-nr">00430</span> | MP-ID | — | X | <span className="hbs-marke">[118]</span> |
| <span className="hbs-f hbs-e1">`3055 9`</span><span className="hbs-nr">00440</span> | GS1 | — | X | — |
| <span className="hbs-f hbs-e1">`3055 332`</span><span className="hbs-nr">00450</span> | DE, DVGW Service & Consult GmbH | — | X | — |
| <span className="hbs-g hbs-e0">**UNS**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`0081 D`</span><span className="hbs-nr">00460</span> | Separation of header and detail section | — | X | — |
| <span className="hbs-g hbs-e0">**SG5.NAD**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3035 DP`</span><span className="hbs-nr">00470</span> | Supply address | — | X | — |
| <span className="hbs-g hbs-e0">**SG6.LOC**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3227 172`</span><span className="hbs-nr">00480</span> | Reporting point | — | X | — |
| <span className="hbs-f hbs-e1">`3225`</span><span className="hbs-nr">00490</span> | Designation | — | X | (<span className="hbs-marke">[951]</span> <span className="hbs-marke">[510]</span> ∧ (<span className="hbs-marke">[522]</span> ∨ <span className="hbs-marke">[524]</span>)) ⊻ (<span className="hbs-marke">[950]</span> <span className="hbs-marke">[514]</span> ∧ (<span className="hbs-marke">[151]</span> ⊻ <span className="hbs-marke">[152]</span> ∧ ((<span className="hbs-marke">[523]</span> ∨ <span className="hbs-marke">[525]</span>)))) |
| <span className="hbs-g hbs-e0">**SG9.LIN**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1082`</span><span className="hbs-nr">00500</span> | Line item number | — | X | <span className="hbs-marke">[908]</span> |
| <span className="hbs-g hbs-e0">**SG9.PIA**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`4347 5`</span><span className="hbs-nr">00510</span> | Product identification | — | X | — |
| <span className="hbs-f hbs-e1">`7140`</span><span className="hbs-nr">00520</span> | Medium / OBIS code number | — | X | (<span className="hbs-marke">[152]</span> ∧ <span className="hbs-marke">[51]</span> ∧ <span className="hbs-marke">[501]</span>) ⊻ (<span className="hbs-marke">[151]</span> ∧ <span className="hbs-marke">[501]</span>) |
| <span className="hbs-f hbs-e1">`7143 SRW`</span><span className="hbs-nr">00530</span> | OBIS code | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.QTY**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`6063 220`</span><span className="hbs-nr">00540</span> | True value | — | X | — |
| <span className="hbs-f hbs-e1">`6063 67`</span><span className="hbs-nr">00550</span> | Substitute value | — | X | (<span className="hbs-marke">[152]</span> ∧ <span className="hbs-marke">[32]</span> ∧ (<span className="hbs-marke">[33]</span> ∨ <span className="hbs-marke">[36]</span> ∨ <span className="hbs-marke">[42]</span>)) ⊻ <span className="hbs-marke">[151]</span> |
| <span className="hbs-f hbs-e1">`6063 201`</span><span className="hbs-nr">00560</span> | Proposed value | — | X | (<span className="hbs-marke">[152]</span> ∧ <span className="hbs-marke">[35]</span> ∧ (<span className="hbs-marke">[33]</span> ∨ <span className="hbs-marke">[36]</span>) ∧ <span className="hbs-marke">[12]</span>) |
| <span className="hbs-f hbs-e1">`6063 20`</span><span className="hbs-nr">00570</span> | Unusable value | — | X | (<span className="hbs-marke">[152]</span> ∧ <span className="hbs-marke">[35]</span> ∧ (<span className="hbs-marke">[33]</span> ∨ <span className="hbs-marke">[36]</span>)) |
| <span className="hbs-f hbs-e1">`6063 187`</span><span className="hbs-nr">00580</span> | Forecast value | — | X | <span className="hbs-marke">[152]</span> ∧ <span className="hbs-marke">[32]</span> ∧ <span className="hbs-marke">[33]</span> ∧ <span className="hbs-marke">[11]</span> |
| <span className="hbs-f hbs-e1">`6060`</span><span className="hbs-nr">00590</span> | Quantity | — | X | ((<span className="hbs-marke">[902]</span> ∧ <span className="hbs-marke">[937]</span> <span className="hbs-marke">[46]</span> ∧ <span className="hbs-marke">[573]</span>) ∨ (<span className="hbs-marke">[902]</span> ∧ <span className="hbs-marke">[907]</span> <span className="hbs-marke">[48]</span> ∧ <span className="hbs-marke">[62]</span>) ∨ (<span className="hbs-marke">[910]</span> ∧ <span className="hbs-marke">[906]</span> <span className="hbs-marke">[62]</span>) <span className="hbs-marke">[152]</span>) ⊻ (<span className="hbs-marke">[902]</span> ∧ <span className="hbs-marke">[906]</span> ∧ <span className="hbs-marke">[151]</span>) |
| <span className="hbs-g hbs-e0">**SG10.DTM**</span> | — | — | Must | <span className="hbs-marke">[152]</span> ⊻ (<span className="hbs-marke">[151]</span> ∧ <span className="hbs-marke">[153]</span>) |
| <span className="hbs-f hbs-e1">`2005 163`</span><span className="hbs-nr">00600</span> | Processing, start date/time | — | X | — |
| <span className="hbs-f hbs-e1">`2380`</span><span className="hbs-nr">00610</span> | Date or time or time span, value | — | X | (((<span className="hbs-marke">[UB2]</span> ∧ <span className="hbs-marke">[119]</span>) ⊻ (<span className="hbs-marke">[931]</span> <span className="hbs-marke">[38]</span>)) ∧ <span className="hbs-marke">[495]</span>) |
| <span className="hbs-f hbs-e1">`2379 303`</span><span className="hbs-nr">00620</span> | CCYYMMDDHHMMZZZ | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.DTM**</span> | — | — | Must | <span className="hbs-marke">[152]</span> ⊻ (<span className="hbs-marke">[151]</span> ∧ <span className="hbs-marke">[153]</span>) |
| <span className="hbs-f hbs-e1">`2005 164`</span><span className="hbs-nr">00630</span> | Processing, end date/time | — | X | — |
| <span className="hbs-f hbs-e1">`2380`</span><span className="hbs-nr">00640</span> | Date or time or time span, value | — | X | (((<span className="hbs-marke">[UB2]</span> ∧ <span className="hbs-marke">[119]</span>) ⊻ (<span className="hbs-marke">[931]</span> <span className="hbs-marke">[38]</span>)) ∧ <span className="hbs-marke">[495]</span>) |
| <span className="hbs-f hbs-e1">`2379 303`</span><span className="hbs-nr">00650</span> | CCYYMMDDHHMMZZZ | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.DTM**</span> | — | — | Must | <span className="hbs-marke">[151]</span> ∧ <span className="hbs-marke">[154]</span> |
| <span className="hbs-f hbs-e1">`2005 306`</span><span className="hbs-nr">00660</span> | Demand period | — | X | — |
| <span className="hbs-f hbs-e1">`2380`</span><span className="hbs-nr">00670</span> | Date or time or time span, value | — | X | — |
| <span className="hbs-f hbs-e1">`2379 610`</span><span className="hbs-nr">00680</span> | CCYYMM | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.STS**</span> | — | — | Should | (<span className="hbs-marke">[92]</span> ⊻ <span className="hbs-marke">[93]</span> ⊻ <span className="hbs-marke">[94]</span>) ∧ <span className="hbs-marke">[126]</span> ∧ <span className="hbs-marke">[152]</span> |
| <span className="hbs-f hbs-e1">`9015 Z33`</span><span className="hbs-nr">00690</span> | Plausibility check note | — | X | — |
| <span className="hbs-f hbs-e1">`9013 Z83`</span><span className="hbs-nr">00700</span> | Customer self-reading | — | X | <span className="hbs-marke">[5P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z84`</span><span className="hbs-nr">00710</span> | Vacancy | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[5P0..1]</span> ⊻ <span className="hbs-marke">[6P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z85`</span><span className="hbs-nr">00720</span> | Actual meter overflow checked | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[5P0..1]</span> ⊻ <span className="hbs-marke">[6P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z86`</span><span className="hbs-nr">00730</span> | Plausible due to check reading | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[5P0..1]</span> ⊻ <span className="hbs-marke">[6P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z87`</span><span className="hbs-nr">00740</span> | Plausible due to customer information | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[5P0..1]</span> ⊻ <span className="hbs-marke">[6P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZC3`</span><span className="hbs-nr">00750</span> | Exchange of the substitute value | — | X | <span className="hbs-marke">[5P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZR5`</span><span className="hbs-nr">00760</span> | Calculated value | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[5P0..1]</span> ⊻ <span className="hbs-marke">[6P0..1]</span> |
| <span className="hbs-g hbs-e0">**SG10.STS**</span> | — | — | Must | <span className="hbs-marke">[152]</span> ∧ (<span className="hbs-marke">[92]</span> ⊻ <span className="hbs-marke">[94]</span>) |
| <span className="hbs-f hbs-e1">`9015 Z32`</span><span className="hbs-nr">00770</span> | Substitute value formation procedure | — | X | — |
| <span className="hbs-f hbs-e1">`9013 Z89`</span><span className="hbs-nr">00780</span> | Comparative measurement (not calibrated) | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[6P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z90`</span><span className="hbs-nr">00790</span> | Meter reading value simulation from calibrated values | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[6P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z91`</span><span className="hbs-nr">00800</span> | Meter reading value simulation from non-calibrated values | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[6P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z92`</span><span className="hbs-nr">00810</span> | Interpolation | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[6P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z93`</span><span className="hbs-nr">00820</span> | Hold value | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[6P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z94`</span><span className="hbs-nr">00830</span> | Balancing grid section | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[6P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z95`</span><span className="hbs-nr">00840</span> | Historical meter reading values | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[6P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZQ8`</span><span className="hbs-nr">00850</span> | Distribution | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[6P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZQ9`</span><span className="hbs-nr">00860</span> | Use of values from the fault quantity register | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[6P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZR0`</span><span className="hbs-nr">00870</span> | Bypass and correction quantities | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[6P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZS0`</span><span className="hbs-nr">00880</span> | Substitute value procedure according to the details at the level of the metering location | — | X | <span className="hbs-marke">[46]</span> ∧ <span className="hbs-marke">[568]</span> |
| <span className="hbs-g hbs-e0">**SG10.STS**</span> | — | — | Should | <span className="hbs-marke">[127]</span> ∧ <span className="hbs-marke">[559]</span> ∧ <span className="hbs-marke">[152]</span> |
| <span className="hbs-f hbs-e1">`9015 Z34`</span><span className="hbs-nr">00890</span> | Reason for correction | — | X | — |
| <span className="hbs-f hbs-e1">`9013 Z74`</span><span className="hbs-nr">00900</span> | no access | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[6P0..1]</span> ⊻ <span className="hbs-marke">[7P0..1]</span> ⊻ <span className="hbs-marke">[8P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z75`</span><span className="hbs-nr">00910</span> | Communication fault | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[6P0..1]</span> ⊻ <span className="hbs-marke">[7P0..1]</span> ⊻ <span className="hbs-marke">[8P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z76`</span><span className="hbs-nr">00920</span> | Grid outage | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[6P0..1]</span> ⊻ <span className="hbs-marke">[7P0..1]</span> ⊻ <span className="hbs-marke">[8P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z78`</span><span className="hbs-nr">00930</span> | Device replacement | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[6P0..1]</span> ⊻ <span className="hbs-marke">[7P0..1]</span> ⊻ <span className="hbs-marke">[8P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z80`</span><span className="hbs-nr">00940</span> | Device operates outside the operating conditions | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[6P0..1]</span> ⊻ <span className="hbs-marke">[7P0..1]</span> ⊻ <span className="hbs-marke">[8P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z81`</span><span className="hbs-nr">00950</span> | Measuring equipment faulty/defective | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[6P0..1]</span> ⊻ <span className="hbs-marke">[7P0..1]</span> ⊻ <span className="hbs-marke">[8P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z82`</span><span className="hbs-nr">00960</span> | Measurement uncertainty | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[6P0..1]</span> ⊻ <span className="hbs-marke">[7P0..1]</span> ⊻ <span className="hbs-marke">[8P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z98`</span><span className="hbs-nr">00970</span> | Consideration of the fault quantity register | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[6P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z99`</span><span className="hbs-nr">00980</span> | Volume conversion incomplete | — | X | <span className="hbs-marke">[6P0..1]</span> ⊻ <span className="hbs-marke">[7P0..1]</span> ⊻ <span className="hbs-marke">[8P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZA0`</span><span className="hbs-nr">00990</span> | Time set /synchronisation | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[6P0..1]</span> ⊻ <span className="hbs-marke">[7P0..1]</span> ⊻ <span className="hbs-marke">[8P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZA1`</span><span className="hbs-nr">01000</span> | Meter reading value implausible | — | X | <span className="hbs-marke">[6P0..1]</span> ⊻ <span className="hbs-marke">[7P0..1]</span> ⊻ <span className="hbs-marke">[8P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZA4`</span><span className="hbs-nr">01010</span> | Incorrect reading | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[5P0..1]</span> ⊻ <span className="hbs-marke">[6P0..1]</span> ⊻ <span className="hbs-marke">[7P0..1]</span> ⊻ <span className="hbs-marke">[8P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZA5`</span><span className="hbs-nr">01020</span> | Change of the calculation | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[5P0..1]</span> ⊻ <span className="hbs-marke">[6P0..1]</span> ⊻ <span className="hbs-marke">[7P0..1]</span> ⊻ <span className="hbs-marke">[8P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZA6`</span><span className="hbs-nr">01030</span> | Conversion of the metering location | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[5P0..1]</span> ⊻ <span className="hbs-marke">[6P0..1]</span> ⊻ <span className="hbs-marke">[7P0..1]</span> ⊻ <span className="hbs-marke">[8P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZA7`</span><span className="hbs-nr">01040</span> | Data processing error | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[5P0..1]</span> ⊻ <span className="hbs-marke">[6P0..1]</span> ⊻ <span className="hbs-marke">[7P0..1]</span> ⊻ <span className="hbs-marke">[8P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZA8`</span><span className="hbs-nr">01050</span> | Calorific value correction | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[5P0..1]</span> ⊻ <span className="hbs-marke">[6P0..1]</span> ⊻ <span className="hbs-marke">[7P0..1]</span> ⊻ <span className="hbs-marke">[8P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZA9`</span><span className="hbs-nr">01060</span> | Z-number correction | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[5P0..1]</span> ⊻ <span className="hbs-marke">[6P0..1]</span> ⊻ <span className="hbs-marke">[7P0..1]</span> ⊻ <span className="hbs-marke">[8P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZB0`</span><span className="hbs-nr">01070</span> | Fault / defect of measuring equipment | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[5P0..1]</span> ⊻ <span className="hbs-marke">[6P0..1]</span> ⊻ <span className="hbs-marke">[7P0..1]</span> ⊻ <span className="hbs-marke">[8P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZC4`</span><span className="hbs-nr">01080</span> | Pulse value not sufficient | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[7P0..1]</span> ⊻ <span className="hbs-marke">[8P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZJ9`</span><span className="hbs-nr">01090</span> | Energy quantity from the unpaired time interval | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[5P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZR1`</span><span className="hbs-nr">01100</span> | Maintenance work on a calibrated measuring device | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[6P0..1]</span> ⊻ <span className="hbs-marke">[7P0..1]</span> ⊻ <span className="hbs-marke">[8P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZR2`</span><span className="hbs-nr">01110</span> | faulty values | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[6P0..1]</span> ⊻ <span className="hbs-marke">[7P0..1]</span> ⊻ <span className="hbs-marke">[8P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZR3`</span><span className="hbs-nr">01120</span> | Maintenance work on measuring devices compliant with calibration law | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[6P0..1]</span> ⊻ <span className="hbs-marke">[7P0..1]</span> ⊻ <span className="hbs-marke">[8P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZR4`</span><span className="hbs-nr">01130</span> | Consistency and synchronisation check | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[6P0..1]</span> ⊻ <span className="hbs-marke">[7P0..1]</span> ⊻ <span className="hbs-marke">[8P0..1]</span> |
| <span className="hbs-g hbs-e0">**SG10.STS**</span> | — | — | Must | <span className="hbs-marke">[92]</span> ∧ <span className="hbs-marke">[152]</span> |
| <span className="hbs-f hbs-e1">`9015 Z40`</span><span className="hbs-nr">01140</span> | Reason for substitute value formation | — | X | — |
| <span className="hbs-f hbs-e1">`9013 Z74`</span><span className="hbs-nr">01150</span> | no access | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z75`</span><span className="hbs-nr">01160</span> | Communication fault | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z76`</span><span className="hbs-nr">01170</span> | Grid outage | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z78`</span><span className="hbs-nr">01180</span> | Device replacement | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z80`</span><span className="hbs-nr">01190</span> | Device operates outside the operating conditions | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z81`</span><span className="hbs-nr">01200</span> | Measuring equipment faulty/defective | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z82`</span><span className="hbs-nr">01210</span> | Measurement uncertainty | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z98`</span><span className="hbs-nr">01220</span> | Consideration of the fault quantity register | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z99`</span><span className="hbs-nr">01230</span> | Volume conversion incomplete | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZA0`</span><span className="hbs-nr">01240</span> | Time set /synchronisation | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZA1`</span><span className="hbs-nr">01250</span> | Meter reading value implausible | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZA4`</span><span className="hbs-nr">01260</span> | Incorrect reading | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZA5`</span><span className="hbs-nr">01270</span> | Change of the calculation | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZA6`</span><span className="hbs-nr">01280</span> | Conversion of the metering location | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZA7`</span><span className="hbs-nr">01290</span> | Data processing error | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZB0`</span><span className="hbs-nr">01300</span> | Fault / defect of measuring equipment | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZC4`</span><span className="hbs-nr">01310</span> | Pulse value not sufficient | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZR1`</span><span className="hbs-nr">01320</span> | Maintenance work on a calibrated measuring device | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZR2`</span><span className="hbs-nr">01330</span> | faulty values | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZR3`</span><span className="hbs-nr">01340</span> | Maintenance work on measuring devices compliant with calibration law | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZR4`</span><span className="hbs-nr">01350</span> | Consistency and synchronisation check | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZS9`</span><span className="hbs-nr">01360</span> | Reason for substitute value formation according to the information at metering location level | — | X | <span className="hbs-marke">[46]</span> ∧ <span className="hbs-marke">[570]</span> |
| <span className="hbs-g hbs-e0">**SG10.STS**</span> | — | — | Should | <span className="hbs-marke">[97]</span> ∧ <span className="hbs-marke">[152]</span> |
| <span className="hbs-f hbs-e1">`9015 Z31`</span><span className="hbs-nr">01370</span> | Gas quality | — | X | — |
| <span className="hbs-f hbs-e1">`9013 ZG3`</span><span className="hbs-nr">01380</span> | Change of gas quality | — | X | — |
| <span className="hbs-g hbs-e0">**UNT**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`0074`</span><span className="hbs-nr">01390</span> | Number of segments in a message | — | X | — |
| <span className="hbs-f hbs-e1">`0062`</span><span className="hbs-nr">01400</span> | Message reference number | — | X | — |
| <span className="hbs-g hbs-e0">**UNZ**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`0036`</span><span className="hbs-nr">01410</span> | Interchange counter | — | X | — |
| <span className="hbs-f hbs-e1">`0020`</span><span className="hbs-nr">01420</span> | Interchange control reference | — | X | — |

</div>

</Handbuchsatz>

### Conditions of this table

The free text of the 62 conditions referenced by the rows above. All conditions of the message type are listed in the [condition index MSCONS](/en/referenz/202604/ahb-bedingungen/MSCONS).

<div className="maco-tabellenrahmen">

| Marker | Condition |
|---|---|
| **[11]** | If SG9 PIA+5+7-0?:52.0.22/7-0?:54.0.16/7-0?:54.0.20/7-0?:54.0.22 |
| **[12]** | If not SG9 PIA+5+7-0?:52.0.22/7-0?:54.0.16/7-0?:54.0.20/7-0?:54.0.22 |
| **[32]** | if MP-ID in SG2 NAD+MS in the role NB |
| **[33]** | if MP-ID in SG2 NAD+MR in the role LF |
| **[35]** | if MP-ID in SG2 NAD+MS in the role MSB |
| **[36]** | if MP-ID in SG2 NAD+MR in the role NB |
| **[38]** | if the ID of the metering location is stated in SG6 LOC+172 DE3225 |
| **[42]** | If MP-ID in SG2 NAD+MR in the role MSB |
| **[46]** | If the value in SG6 LOC+172 DE3225 has exactly 11 digits |
| **[48]** | If SG9 PIA+5+7-0?:52.0.22 |
| **[51]** | If SG9 PIA+5+7-0?:33.86.0 is present, SG9 PIA+5+7-0?:52.0.22/7-0?:54.0.16/7-0?:54.0.20/7-0?:54.0.22 must no longer be specified by repeating SG9 LIN in the same message |
| **[62]** | If the value in SG6 LOC+172 DE3225 has exactly 33 digits |
| **[92]** | If SG10 QTY DE6063 with value 67 is present |
| **[93]** | If SG10 QTY DE6063 with value 220 is present |
| **[94]** | If SG10 QTY DE6063 with value 201 is present |
| **[97]** | If this concerns the transmission of a value due to the change of the gas quality |
| **[118]** | Only MP-ID from the gas division |
| **[119]** | if the ID of the market location is stated in SG6 LOC+172 DE3225 |
| **[126]** | if plausibility check notices exist |
| **[127]** | if a correction reason has to be stated |
| **[142]** | if the code EM is present in DE3155 in the same COM |
| **[143]** | if the code TE / FX / AJ / AL is present in DE3155 in the same COM |
| **[151]** | If BGM+Z27 (transaction data in the calendar year before start of supply) present. |
| **[152]** | If BGM+7 (process data report) present. |
| **[153]** | If SG9 PIA+5+7-0?:33.86.0 is present |
| **[154]** | If SG9 PIA+5+7-0?:33.47.0 is present |
| **[494]** | The date stated here must be the point in time at which the document was created, or a point in time before that. |
| **[495]** | The point in time must be ≤ the value in DE2380 of DTM+137 |
| **[501]** | Note: Only the values that are marked with the corresponding check identifier in the EDI@Energy code list of the OBIS codes and media are permitted. |
| **[509]** | Note: If this is a correction energy quantity, the reference to the MSCONS in which the meter reading was transmitted in advance must be specified here. |
| **[510]** | Note: Use of the ID of the metering location |
| **[514]** | Note: Use of the ID of the market location |
| **[522]** | Note: Only for the transmission of the correction energy quantities in the time interval between two metered values. |
| **[523]** | Note: Only for the transmission of the energy quantity in the time interval between two metered values before the grid usage settlement. |
| **[524]** | Note: Only if it concerns the transmission of the billing calorific value and Z number for the period requested by the supplier via a business data request. |
| **[525]** | Note: Only for the transmission of the energy quantity in the time interval for a market location without a metering location (flat-rate installation) if one of the events from chapter 4.2 has occurred. |
| **[529]** | Note: Value from BGM+7 DE1004 of the ORDERS with which the request for meter reading values was made. |
| **[531]** | Note: Value from BGM+7 DE1004 of the MSCONS with which the meter reading was transmitted. |
| **[559]** | Note: A correction reason is to be specified if: 1. a preliminary value already transmitted to the MP is replaced by a substitute value after cancellation, or 2. a substitute value already transmitted to the MP is replaced by a substitute value after cancellation, or 3. a true value already transmitted to the MP is replaced by a substitute value after cancellation, or 4. a true value already transmitted to the MP is replaced by a true value after cancellation. |
| **[568]** | Note: Use is permitted only if it is a 1:n relationship between market and metering location and different substitute value determination procedures have been used and communicated at the level of the metering location. |
| **[570]** | Note: Use is permitted only if it is a 1:n relationship between market and metering location and different reasons for the substitute value determination exist at the level of the metering location and have been communicated. |
| **[573]** | Note: An energy quantity in the gas division is to be rounded to whole kilowatt hours in accordance with DVGW G685 worksheet 4 chapter 5.3. |
| **[576]** | Note: Only one piece of information may be transmitted in DE3148 |
| **[902]** | Format: Possible value: ≥ 0 |
| **[906]** | Format: max. 3 decimal places |
| **[907]** | Format: max. 4 decimal places |
| **[908]** | Format: possible values: 1 to n |
| **[910]** | Format: Possible value: &lt; 0 or ≥ 0 |
| **[918]** | Format: Characters from the character set defined via UNOC, where only capital letters are permitted among the letters. |
| **[931]** | Format: ZZZ = +00 |
| **[937]** | Format: no decimal places |
| **[939]** | Format: the character string must contain the characters @ and . |
| **[940]** | Format: the character string must begin with the character + and may only be followed by digits |
| **[950]** | Format: market location ID |
| **[951]** | Format: Metering point identifier |
| **[1P0..1]** | Note: This is the standard package if no condition applies,  e.g. in the COM segment |
| **[UB2]** | ([931] ∧ [934] [490]) ⊻ ([931] ∧ [935] [491]) |
| **[5P0..1]** | [93]  If SG10 QTY DE6063 with value 220 present |
| **[4P0..1]** | [92]  If SG10 QTY DE6063 with value 67 present |
| **[6P0..1]** | [94]  If SG10 QTY DE6063   with value 201 present |
| **[7P0..1]** | [95]  If SG10 QTY DE6063   with value  20  present |
| **[8P0..1]** | [96]  If SG10 QTY DE6063   with value Z18 present |

</div>

## Example message

### Example 1

<div data-maco="beispielfall" className="maco-beispielfall">

<Beispielnachricht>

```text title="EDIFACT"
UNA:+.? '
UNB+UNOC:3+9870013800007:502+9800044300007:502+{{date}}:{{time}}+165425++EM'
UNH+434072+MSCONS:D:04B:UN:2.4c'
BGM+7+34072BGM+9'
DTM+137:202307310939?+00:303'
RFF+AGI:12345678910'
RFF+Z13:13009'
NAD+MS+9870013800007::332'
CTA+IC+:Max Mustermann'
COM+?+012345678910:TE'
NAD+MR+9800044300007::332'
UNS+D'
NAD+DP'
LOC+172+50074561188'
LIN+1'
PIA+5+7-0?:33.86.0:SRW'
QTY+220:1000'
DTM+163:202306010400?+00:303'
DTM+164:202307010400?+00:303'
UNT+18+434072'
UNZ+1+165425'
```

```json title="BO4E-JSON"
[
  {
    "businessKey": "<businessKey>",
    "processDate": null,
    "dataSource": "OUTBOUND",
    "version": 1,
    "edifactVersion": 202604,
    "data": {
      "stammdaten": {
        "ENERGIEMENGE": [
          {
            "boTyp": "ENERGIEMENGE",
            "versionStruktur": "1",
            "lokationsId": "50074561188",
            "lokationsTyp": "MALO",
            "energieverbrauch": [
              {
                "messwertstatus": "ABGELESEN",
                "obiskennzahl": "7-0:33.86.0",
                "wert": 1000,
                "position": 1,
                "startdatum": "2023-06-01T04:00:00Z",
                "enddatum": "2023-07-01T04:00:00Z"
              }
            ]
          }
        ]
      },
      "transaktionsdaten": {
        "datenaustauschreferenz": "165425",
        "sparte": "GAS",
        "pruefidentifikator": "13009",
        "absender": {
          "boTyp": "MARKTTEILNEHMER",
          "versionStruktur": "1",
          "marktrolle": "NB",
          "rollencodenummer": "9870013800007",
          "rollencodetyp": "DVGW",
          "ansprechpartner": {
            "boTyp": "ANSPRECHPARTNER",
            "versionStruktur": "1",
            "nachname": "Max Mustermann",
            "rufnummern": [
              {
                "nummerntyp": "RUF_DURCHWAHL",
                "rufnummer": "+012345678910"
              }
            ]
          }
        },
        "empfaenger": {
          "boTyp": "MARKTTEILNEHMER",
          "versionStruktur": "1",
          "marktrolle": "LF",
          "rollencodenummer": "9800044300007",
          "rollencodetyp": "DVGW"
        },
        "dokumentennummer": "34072BGM",
        "kategorie": "7",
        "nachrichtenfunktion": "9",
        "nachrichtendatum": "2023-07-31T09:39:00Z",
        "nachrichtenreferenznummer": "434072",
        "typ": "EM",
        "anfrageReferenz": "12345678910"
      },
      "zusatzdaten": []
    }
  }
]
```

</Beispielnachricht>

*Source: [`1.edi`](https://github.com/conuti-gmbh/maco-edi-testfiles/blob/main/inbound/v202604/mscons/13009/1.edi) · [`1.json`](https://github.com/conuti-gmbh/maco-edi-testfiles/blob/main/outbound/v202604/mscons/13009/1.json)*

<Testdateien edi="/testdaten/202604/mscons/13009/1.edi" json="/testdaten/202604/mscons/13009/1.json" />

</div>

### Example 2

<div data-maco="beispielfall" className="maco-beispielfall">

<Beispielnachricht>

```text title="EDIFACT"
UNA:+.? '
UNB+UNOC:3+9870006600000:502+9800009600004:502+{{date}}:{{time}}+MRMAMNBB++EM'
UNH+MR6SSUIG+MSCONS:D:04B:UN:2.4c'
BGM+Z27+MQWHBJV2+9'
DTM+137:202606240949?+00:303'
RFF+Z13:13009'
NAD+MS+9870006600000::332'
NAD+MR+9800009600004::332'
UNS+D'
NAD+DP'
LOC+172+50074561188'
LIN+1'
PIA+5+7-0?:33.47.0:SRW'
QTY+220:500'
DTM+306:202603:610'
STS+Z33++Z83'
UNT+15+MR6SSUIG'
UNZ+1+MRMAMNBB'
```

```json title="BO4E-JSON"
[
  {
    "businessKey": "<businessKey>",
    "processDate": null,
    "dataSource": "OUTBOUND",
    "version": 1,
    "edifactVersion": 202604,
    "data": {
      "stammdaten": {
        "ENERGIEMENGE": [
          {
            "boTyp": "ENERGIEMENGE",
            "versionStruktur": "1",
            "lokationsId": "50074561188",
            "lokationsTyp": "MALO",
            "energieverbrauch": [
              {
                "messwertstatus": "ABGELESEN",
                "statuszusatzinformationen": [
                  {
                    "art": "PLAUSIBILISIERUNGSHINWEIS",
                    "status": "KUNDENSELBSTABLESUNG"
                  }
                ],
                "obiskennzahl": "7-0:33.47.0",
                "wert": 500,
                "position": 1,
                "leistungsperiode": "202603"
              }
            ]
          }
        ]
      },
      "transaktionsdaten": {
        "datenaustauschreferenz": "MRMAMNBB",
        "sparte": "GAS",
        "pruefidentifikator": "13009",
        "absender": {
          "boTyp": "MARKTTEILNEHMER",
          "versionStruktur": "1",
          "gewerbekennzeichnung": true,
          "rollencodenummer": "9870006600000",
          "rollencodetyp": "DVGW"
        },
        "empfaenger": {
          "boTyp": "MARKTTEILNEHMER",
          "versionStruktur": "1",
          "gewerbekennzeichnung": true,
          "rollencodenummer": "9800009600004",
          "rollencodetyp": "DVGW"
        },
        "dokumentennummer": "MQWHBJV2",
        "kategorie": "Z27",
        "nachrichtenfunktion": "9",
        "nachrichtendatum": "2026-06-24T09:49:00Z",
        "nachrichtenreferenznummer": "MR6SSUIG",
        "typ": "EM"
      },
      "zusatzdaten": {}
    }
  }
]
```

</Beispielnachricht>

*Source: [`2.edi`](https://github.com/conuti-gmbh/maco-edi-testfiles/blob/main/inbound/v202604/mscons/13009/2.edi) · [`2.json`](https://github.com/conuti-gmbh/maco-edi-testfiles/blob/main/outbound/v202604/mscons/13009/2.json)*

<Testdateien edi="/testdaten/202604/mscons/13009/2.edi" json="/testdaten/202604/mscons/13009/2.json" />

</div>

## Belongs to these role views

The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are **LF**, **NB** and **MSB**.

<div className="maco-tabellenrahmen">

| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | [Billing of grid usage](/en/prozessdoku/202604/LF/geli-gas-2-0-abrechnung-der-netznutzung) | GeLi Gas 2.0 | Gas | Step 1 |
| LF | LF | [Request and provision of measured values](/en/prozessdoku/202604/LF/geli-gas-2-0-anforderung-und-bereitstellung-von-messwerten) | GeLi Gas 2.0 | Gas | Step 3 |
| LF | LF | [Request and provision of measured values](/en/prozessdoku/202604/LF/geli-gas-2-0-anforderung-und-bereitstellung-von-messwerten) | GeLi Gas 2.0 | Gas | Step 5 |
| LF | LF | [Request and provision of measured values](/en/prozessdoku/202604/LF/geli-gas-2-0-anforderung-und-bereitstellung-von-messwerten) | GeLi Gas 2.0 | Gas | Step 6 |
| LF | LF | [Request for calorific value and conversion factor](/en/prozessdoku/202604/LF/geli-gas-2-0-anforderung-von-brennwert-und-zustandszahl) | GeLi Gas 2.0 | Gas | Step 2 |
| LF | LF | [Business data request from the LF to NB](/en/prozessdoku/202604/LF/geli-gas-2-0-geschaftsdatenanfrage-vom-lf-an-nb) | GeLi Gas 2.0 | Gas | Step 2 |
| LF | LF | [Transmission of the energy and demand values measured so far](/en/prozessdoku/202604/LF/geli-gas-2-0-ubermittlung-der-bisher-gemessenen-arbeits-und-leistungswerte) | GeLi Gas 2.0 | Gas | Step 1 |
| NB | NB | [Transmission of values from the MSB to NB](/en/prozessdoku/202604/NB/awh-wim-gas-2-0-ubermittlung-von-werten-vom-msb-an-nb) | AWH WiM gas 2.0 | Gas | Step 1 |
| NB | NB | [Billing of grid usage](/en/prozessdoku/202604/NB/geli-gas-2-0-abrechnung-der-netznutzung) | GeLi Gas 2.0 | Gas | Step 1 |
| NB | NB | [Request and provision of measured values](/en/prozessdoku/202604/NB/geli-gas-2-0-anforderung-und-bereitstellung-von-messwerten) | GeLi Gas 2.0 | Gas | Step 3 |
| NB | NB | [Request and provision of measured values](/en/prozessdoku/202604/NB/geli-gas-2-0-anforderung-und-bereitstellung-von-messwerten) | GeLi Gas 2.0 | Gas | Step 5 |
| NB | NB | [Request and provision of measured values](/en/prozessdoku/202604/NB/geli-gas-2-0-anforderung-und-bereitstellung-von-messwerten) | GeLi Gas 2.0 | Gas | Step 6 |
| NB | NB | [Request for calorific value and conversion factor](/en/prozessdoku/202604/NB/geli-gas-2-0-anforderung-von-brennwert-und-zustandszahl) | GeLi Gas 2.0 | Gas | Step 2 |
| NB | NB | [Non-scheduled meter reading transmission](/en/prozessdoku/202604/NB/geli-gas-2-0-ausserturnusmassige-messwertubermittlung) | GeLi Gas 2.0 | Gas | Step 3 |
| NB | NB | [Business data request from the LF to NB](/en/prozessdoku/202604/NB/geli-gas-2-0-geschaftsdatenanfrage-vom-lf-an-nb) | GeLi Gas 2.0 | Gas | Step 2 |
| NB | NB | [Scheduled/regular meter reading transmission](/en/prozessdoku/202604/NB/geli-gas-2-0-turnusmassige-regelmassige-messwertubermittlung) | GeLi Gas 2.0 | Gas | Step 1 |
| NB | NB | [Scheduled/regular meter reading transmission](/en/prozessdoku/202604/NB/geli-gas-2-0-turnusmassige-regelmassige-messwertubermittlung) | GeLi Gas 2.0 | Gas | Step 2 |
| NB | NB | [Transmission of the energy and demand values measured so far](/en/prozessdoku/202604/NB/geli-gas-2-0-ubermittlung-der-bisher-gemessenen-arbeits-und-leistungswerte) | GeLi Gas 2.0 | Gas | Step 1 |
| MSB | MSB | [Transmission of values from the MSB to NB](/en/prozessdoku/202604/MSB/awh-wim-gas-2-0-ubermittlung-von-werten-vom-msb-an-nb) | AWH WiM gas 2.0 | Gas | Step 1 |
| MSB | MSB | [Request and provision of measured values](/en/prozessdoku/202604/MSB/geli-gas-2-0-anforderung-und-bereitstellung-von-messwerten) | GeLi Gas 2.0 | Gas | Step 3 |
| MSB | MSB | [Request and provision of measured values](/en/prozessdoku/202604/MSB/geli-gas-2-0-anforderung-und-bereitstellung-von-messwerten) | GeLi Gas 2.0 | Gas | Step 5 |
| MSB | MSB | [Request and provision of measured values](/en/prozessdoku/202604/MSB/geli-gas-2-0-anforderung-und-bereitstellung-von-messwerten) | GeLi Gas 2.0 | Gas | Step 6 |
| MSB | MSB | [Non-scheduled meter reading transmission](/en/prozessdoku/202604/MSB/geli-gas-2-0-ausserturnusmassige-messwertubermittlung) | GeLi Gas 2.0 | Gas | Step 3 |
| MSB | MSB | [Scheduled/regular meter reading transmission](/en/prozessdoku/202604/MSB/geli-gas-2-0-turnusmassige-regelmassige-messwertubermittlung) | GeLi Gas 2.0 | Gas | Step 1 |
| MSB | MSB | [Scheduled/regular meter reading transmission](/en/prozessdoku/202604/MSB/geli-gas-2-0-turnusmassige-regelmassige-messwertubermittlung) | GeLi Gas 2.0 | Gas | Step 2 |

</div>

## Business classification

<div className="maco-tabellenrahmen">

| Attribute | Value |
|---|---|
| Use case (AHB) | Energy quantity (gas) |
| AHB | MSCONS AHB |
| Response to check identifier | [17102](/schnittstellen/202604/pruefi/ORDERS/PI_17102) |
| Transmission channel | AS4 |

</div>

:::caution{title="This check identifier is used in 19 contexts"}

Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.

:::

<div className="maco-tabellenrahmen">

| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| WiM gas | Ch. B 5.1.3 No. 7 | MSBN → NB | Transmission of final reading values by MSBN or MSBA |
| WiM gas | Ch. B 5.1.3 No. 7 | MSBA → NB | Transmission of final reading values by MSBN or MSBA |
| GeLi Gas 2.0 | Request and provision of meter reading values | MSB → NB | Meter reading transmission |
| GeLi Gas 2.0 | Request and provision of meter reading values | NB → MSB | Transmission of substitute values |
| GeLi Gas 2.0 | Request and provision of meter reading values | NB → LF | Meter reading transmission |
| GeLi Gas 2.0 | Transmission of the energy and demand values measured so far | NB → LF | Energy and demand values measured so far |
| GeLi Gas 2.0 | Periodic/regular meter reading transmission | MSB → NB | Meter reading date for measuring equipment with balancing based on profiles |
| GeLi Gas 2.0 | Periodic/regular meter reading transmission | MSB → NB | Regular reading of measuring equipment with RLM |
| GeLi Gas 2.0 | Periodic/regular meter reading transmission | MSB → NB | End of supply / deregistration request |
| GeLi Gas 2.0 | Off-cycle meter reading transmission | MSB → NB | Interim meter reading |
| GeLi Gas 2.0 | Request for calorific value and conversion factor | NB → LF | Transmission of billing calorific value and conversion factor |
| GeLi Gas 2.0 | Business data request from LF to NB | NB → LF | Response |
| GeLi Gas 2.0 | Billing of grid usage | NB → LF | ongoing meter reading values |
| AWH WiM gas 2.0 | Transmission of values from MSB to NB | MSB → NB | Values |
| GeLi Gas | Ch. D 1.2.4 No. 11 | NB → LF | Meter reading transmission |
| GeLi Gas | Ch. D 1.2.4 No. 7 | MSB → NB | Meter reading transmission |
| GeLi Gas | Ch. D 1.2.4 No. 9 | NB → MSB | Transmission of substitute values |
| GeLi Gas | Ch. D 2.2 No. 2 | NB → LF | Response |
| GeLi Gas | Ch. D 3.2 No. 2 | NB → LF | Response |

</div>

:::caution{title="Further relationships from format version 202610"}

Version 202610 also carries this check identifier in contexts that the table of version 202604 does not know; they are included in the list above. Everything else on this page — use case, rulebook and communication direction — comes from the page's own version. Before adopting it into an implementation specification, check whether what is stated applies to 202604.

:::

## Transaction and responses

**Role of this check identifier: response.** Basis: the title or the action of the Prüfi table begins with “response”. The title names **no** polarity — whether this message confirms or rejects is decided by the response code, not by the check identifier.

### Which request this message responds to

<div className="maco-tabellenrahmen">

| Role | Check identifier | Use case | Message type | Origin of supply |
|---|---|---|---|---|
| Request | [17102](/schnittstellen/202604/pruefi/ORDERS/PI_17102) | Request for values | ORDERS | explicit |

</div>

### In which field the request is quoted

<div className="maco-tabellenrahmen">

| Reference field of this message | EDIFACT segment | Target field in the request |
|---|---|---|
| `anfrageReferenz` | `SG1.RFF+AGI` | `dokumentennummer` |

</div>

RFF+AGI quotes the `BGM` of the request; the target is its `dokumentennummer`. Measured: 17102 carries `dokumentennummer` in `BGM+[7|Z28|Z48]`.

**Check identifiers of the same AHB table:** No other check identifier of message type MSCONS has the same row structure in this version.

<Hinweisbereich>

An **\*** after a field or group name marks a **mandatory field** or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.

The status column carries two vocabularies because the manual answers two questions: on a **group row**, *Muss*, *Soll* or *Kann* states whether the EDIFACT segment must be present; on a **field row**, *X* states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.

For this check identifier, the application handbook lists **168 rows**. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.

The **Condition** column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.

The test data contains 2 transactions for this check identifier under the message type `mscons`. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.

:::note{title="Placeholder from the test data set"}

The test data set carries placeholders instead of valid values: `{{date}}` and `{{time}}` in the UNB interchange envelope of every EDIFACT file. **The page replaces these on call with the current date and the current time** — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.

`<businessKey>` stays in place. It is not a time value, and an invented key would look like a valid one.

:::

</Hinweisbereich>
