# Check identifier 13019 — Energy quantity (Electricity)

<span hidden data-pagefind-meta={"title:Check identifier 13019 — Energy quantity (electricity) · MSCONS · Format version 202604"} />

Check identifier **13019** · EDIFACT message type **MSCONS** · Format version **202604**

## Data structure

<Handbuchsatz>

<div className="maco-tabellenrahmen">

| Structure (BO4E) | Description | Format | <span className="hbs-p" title="Energiemenge (Strom)">13019</span> | Condition |
|---|---|---|---|---|
| <span className="hbs-g hbs-e0">**stammdaten** <span className="hbs-pflicht">\*</span></span> | — | object | Must | — |
| <span className="hbs-g hbs-e1">**ENERGIEMENGE** <span className="hbs-liste">[ ]</span> <span className="hbs-pflicht">\*</span></span> | — | object[] | Must | — |
| <span className="hbs-f hbs-e2">[konfiguration](/en/bo4e/202604/bo/Energiemenge#konfiguration)</span> <AhbTabelle pruefid="13019" format="MSCONS" fv="202604" zeile={60} segment="SG5.NAD+DP.SG6.LOC+172" /><span className="hbs-nr">00010</span> | konfiguration | string | X | — |
| <span className="hbs-f hbs-e2">[lokationsId](/en/bo4e/202604/bo/Energiemenge#lokationsid) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13019" format="MSCONS" fv="202604" zeile={60} segment="SG5.NAD+DP.SG6.LOC+172" /><span className="hbs-nr">00020</span> | Unique number of the market location or of the metering location to which the energy quantity belongs | string | X | — |
| <span className="hbs-g hbs-e2">**energieverbrauch** <span className="hbs-liste">[ ]</span> <span className="hbs-pflicht">\*</span></span> | — | object[] | Must | — |
| <span className="hbs-f hbs-e3">[enddatum](/en/bo4e/202604/com/Verbrauch#enddatum) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13019" format="MSCONS" fv="202604" zeile={81} segment="SG5.NAD+DP.SG6.LOC+172.SG9.LIN.SG10.QTY.DTM+164" /><span className="hbs-nr">00030</span> | enddatum | string (date-time) | X | — |
| <span className="hbs-f hbs-e3">[messwertstatus](/en/bo4e/202604/com/Verbrauch#messwertstatus) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13019" format="MSCONS" fv="202604" zeile={71} segment="SG5.NAD+DP.SG6.LOC+172.SG9.LIN.SG10.QTY" /><span className="hbs-nr">00040</span> | The status of a meter reading | [Enum Messwertstatus](/en/bo4e/202604/enum/Messwertstatus) | Must | — |
| <span className="hbs-w hbs-e4">`ABGELESEN`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`ERSATZWERT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`VORSCHLAGSWERT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`NICHT_VERWENDBAR`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`PROGNOSEWERT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`ENERGIEMENGESUMMIERT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`VOLAEUFIGERWERT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`FEHLT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`ANGABE_FUER_LIEFERSCHEIN`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`GRUNDLAGE_POG_ERMITTLUNG`</span> | — | — | Must | — |
| <span className="hbs-f hbs-e3">[obiskennzahl](/en/bo4e/202604/com/Verbrauch#obiskennzahl) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13019" format="MSCONS" fv="202604" zeile={68} segment="SG5.NAD+DP.SG6.LOC+172.SG9.LIN.PIA+5" /><span className="hbs-nr">00050</span> | obiskennzahl | string | X | — |
| <span className="hbs-f hbs-e3">[position](/en/bo4e/202604/com/Verbrauch#position) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13019" format="MSCONS" fv="202604" zeile={65} segment="SG5.NAD+DP.SG6.LOC+172.SG9.LIN" /><span className="hbs-nr">00060</span> | position | integer | Must | — |
| <span className="hbs-f hbs-e3">[startdatum](/en/bo4e/202604/com/Verbrauch#startdatum) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13019" format="MSCONS" fv="202604" zeile={77} segment="SG5.NAD+DP.SG6.LOC+172.SG9.LIN.SG10.QTY.DTM+163" /><span className="hbs-nr">00070</span> | startdatum | string (date-time) | X | — |
| <span className="hbs-f hbs-e3">[wert](/en/bo4e/202604/com/Verbrauch#wert) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13019" format="MSCONS" fv="202604" zeile={71} segment="SG5.NAD+DP.SG6.LOC+172.SG9.LIN.SG10.QTY" /><span className="hbs-nr">00080</span> | wert | number (float) | Must | — |
| <span className="hbs-g hbs-e3">**statuszusatzinformationen** <span className="hbs-liste">[ ]</span></span> | — | object[] | May | — |
| <span className="hbs-f hbs-e4">[art](/en/bo4e/202604/com/StatusZusatzInformation#art)</span> <AhbTabelle pruefid="13019" format="MSCONS" fv="202604" zeile={92} segment="SG5.NAD+DP.SG6.LOC+172.SG9.LIN.SG10.QTY.STS+Z32" /><span className="hbs-nr">00090</span> | Status type | [Enum StatusArt](/en/bo4e/202604/enum/StatusArt) | X | — |
| <span className="hbs-w hbs-e5">`PLAUSIBILISIERUNGSHINWEIS`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`ERSATZWERTBILDUNGSVERFAHREN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`KORREKTURGRUND`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`GRUND_ERSATZWERTBILDUNGSVERFAHREN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`GASQUALITAET`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`MESSKLASSIFIZIERUNG`</span> | — | — | X | — |
| <span className="hbs-f hbs-e4">[status](/en/bo4e/202604/com/StatusZusatzInformation#status)</span> <AhbTabelle pruefid="13019" format="MSCONS" fv="202604" zeile={92} segment="SG5.NAD+DP.SG6.LOC+172.SG9.LIN.SG10.QTY.STS+Z32" /><span className="hbs-nr">00100</span> | Status | [Enum Status](/en/bo4e/202604/enum/Status) | X | — |
| <span className="hbs-w hbs-e5">`KUNDENSELBSTABLESUNG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`LEERSTAND`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`REALER_ZAEHLERUEBERLAUF_GEPRUEFT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`PLAUSIBEL_WG_KONTROLLABLESUNG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`PLAUSIBEL_WG_KUNDENHINWEIS`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`AUSTAUSCH_DES_ERSATZWERTES`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`RECHENWERT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`BASIS_MME`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`VERGLEICHSMESSUNG_GEEICHT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`VERGLEICHSMESSUNG_NICHT_GEEICHT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`MESSWERTNACHBILDUNG_AUS_GEEICHTEN_WERTEN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`MESSWERTNACHBILDUNG_AUS_NICHT_GEEICHTEN_WERTEN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`INTERPOLATION`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`HALTEWERT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`BILANZIERUNG_NETZABSCHNITT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`HISTORISCHE_MESSWERTE`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`STATISTISCHE_METHODE`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`AUFTEILUNG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`VERWENDUNG_VON_WERTEN_DES_STOERMENGENZAEHLWERKS`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`UMGANGS_UND_KORREKTURMENGEN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`ANGABEN_MESSLOKATION`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`KEIN_ZUGANG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`KOMMUNIKATIONSSTOERUNG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`NETZAUSFALL`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`SPANNUNGSAUSFALL`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`STATUS_GERAETEWECHSEL`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`KALIBRIERUNG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`GERAET_ARBEITET_AUSSERHALB_DER_BETRIEBSBEDINGUNGEN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`MESSEINRICHTUNG_GESTOERT_DEFEKT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`UNSICHERHEIT_MESSUNG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`BERUECKSICHTIGUNG_STOERMENGENZAEHLWERK`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`MENGENUMWERTUNG_VOLLSTAENDIG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`UHRZEIT_GESTELLT_SYNCHRONISATION`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`MESSWERT_UNPLAUSIBEL`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`FALSCHER_WANDLERFAKTOR`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`FEHLERHAFTE_ABLESUNG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`AENDERUNG_DER_BERECHNUNG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`UMBAU_DER_MESSLOKATION`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`DATENBEARBEITUNGSFEHLER`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`BRENNWERTKORREKTUR`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`Z_ZAHL_KORREKTUR`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`STOERUNG_DEFEKT_MESSEINRICHTUNG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`AENDERUNG_TARIFSCHALTZEITEN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`TARIFSCHALTGERAET_DEFEKT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`IMPULSWERTIGKEIT_NICHT_AUSREICHEND`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`ENERGIEMENGE_IN_UNGEMESSENEM_ZEITINTERVALL`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`ENERGIEMENGE_AUS_DEM_UNGEPAIRTEN_ZEITINTERVALL`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`WARTUNGSARBEITEN_AN_GEEICHTEM_MESSGERAET`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`GESTOERTE_WERTE`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`WARTUNGSARBEITEN_AN_EICHRECHTSKONFORMEN_MESSGERAETEN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`KONSISTENZ_UND_SYNCHRONPRUEFUNG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`GRUND_ANGABEN_MESSLOKATION`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`ANFORDERUNG_IN_DIE_VERGANGENHEIT_ZUM_ANGEFORDERTEN_ZEITPUNKT_LIEGT_KEIN_WERT_VOR`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`UMSTELLUNG_GASQUALITAET`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`ZAEHLERSTAND_ZUM_BEGINN_DER_ANGEGEBENEN_ENERGIEMENGE_VORHANDEN_UND_KOMMUNIZIERT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`ZAEHLERSTAND_ZUM_ENDE_DER_ANGEGEBENEN_ENERGIEMENGE_VORHANDEN_UND_KOMMUNIZIERT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`ZAEHLERSTAND_ZUM_BEGINN_DER_ANGEGEBENEN_ENERGIEMENGE_NICHT_VORHANDEN_DA_MENGENABGRENZUNG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`ZAEHLERSTAND_ZUM_ENDE_DER_ANGEGEBENEN_ENERGIEMENGE_NICHT_VORHANDEN_DA_MENGENABGRENZUNG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`GESCHEITERT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`AUSGEBAUT`</span> | — | — | X | — |
| <span className="hbs-g hbs-e0">**transaktionsdaten** <span className="hbs-pflicht">\*</span></span> | — | object | Must | — |
| <span className="hbs-f hbs-e1">[anfrageReferenz](/en/bo4e/202604/cdoc/Transaktionsdaten#anfragereferenz)</span> <AhbTabelle pruefid="13019" format="MSCONS" fv="202604" zeile={30} segment="SG1.RFF+AGI" /><span className="hbs-nr">00110</span> | Application number / RFF+AGI | string | X | — |
| <span className="hbs-f hbs-e1">[dokumentennummer](/en/bo4e/202604/cdoc/Transaktionsdaten#dokumentennummer) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13019" format="MSCONS" fv="202604" zeile={20} segment="BGM" /><span className="hbs-nr">00120</span> | EDIFACT reference from the BGM segment / BGM | string | Must | — |
| <span className="hbs-f hbs-e1">[kategorie](/en/bo4e/202604/cdoc/Transaktionsdaten#kategorie) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13019" format="MSCONS" fv="202604" zeile={20} segment="BGM" /><span className="hbs-nr">00130</span> | Qualifier from the beginning of the EDIFACT message / BGM | string | Must | — |
| <span className="hbs-f hbs-e1">[nachrichtendatum](/en/bo4e/202604/cdoc/Transaktionsdaten#nachrichtendatum) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13019" format="MSCONS" fv="202604" zeile={26} segment="DTM+137" /><span className="hbs-nr">00140</span> | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| <span className="hbs-f hbs-e1">[nachrichtenfunktion](/en/bo4e/202604/cdoc/Transaktionsdaten#nachrichtenfunktion) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13019" format="MSCONS" fv="202604" zeile={20} segment="BGM" /><span className="hbs-nr">00150</span> | Message function code / BGM | string | Must | — |
| <span className="hbs-f hbs-e1">[nachrichtenreferenznummer](/en/bo4e/202604/cdoc/Transaktionsdaten#nachrichtenreferenznummer) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13019" format="MSCONS" fv="202604" zeile={13} segment="UNH" /><span className="hbs-nr">00160</span> | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| <span className="hbs-f hbs-e1">[pruefidentifikator](/en/bo4e/202604/cdoc/Transaktionsdaten#pruefidentifikator) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13019" format="MSCONS" fv="202604" zeile={33} segment="SG1.RFF+Z13" /><span className="hbs-nr">00170</span> | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| <span className="hbs-g hbs-e1">**absender** <span className="hbs-pflicht">\*</span></span> | — | object | Must | — |
| <span className="hbs-f hbs-e2">[rollencodenummer](/en/bo4e/202604/bo/Marktteilnehmer#rollencodenummer) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13019" format="MSCONS" fv="202604" zeile={36} segment="SG2.NAD+MS" /><span className="hbs-nr">00180</span> | Specifies the code value of the market role. | string | X | — |
| <span className="hbs-f hbs-e2">[rollencodetyp](/en/bo4e/202604/bo/Marktteilnehmer#rollencodetyp) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13019" format="MSCONS" fv="202604" zeile={36} segment="SG2.NAD+MS" /><span className="hbs-nr">00190</span> | Indicates the type of the code. | [Enum Rollencodetyp](/en/bo4e/202604/enum/Rollencodetyp) | X | — |
| <span className="hbs-w hbs-e3">`BDEW`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`GS1`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`GLN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`DVGW`</span> | — | — | X | — |
| <span className="hbs-g hbs-e2">**ansprechpartner**</span> | — | object | May | — |
| <span className="hbs-f hbs-e3">[eMailAdresse](/en/bo4e/202604/bo/Ansprechpartner#emailadresse)</span> <AhbTabelle pruefid="13019" format="MSCONS" fv="202604" zeile={43} segment="SG2.NAD+MS.SG4.CTA+IC.COM+[EM\|FX\|TE\|AJ\|AL]" /><span className="hbs-nr">00200</span> | Email address | string | Must | — |
| <span className="hbs-f hbs-e3">[nachname](/en/bo4e/202604/bo/Ansprechpartner#nachname)</span> <AhbTabelle pruefid="13019" format="MSCONS" fv="202604" zeile={41} segment="SG2.NAD+MS.SG4.CTA+IC" /><span className="hbs-nr">00210</span> | Surname (family name) of the contact person | string | X | — |
| <span className="hbs-g hbs-e3">**rufnummern** <span className="hbs-liste">[ ]</span></span> | — | object[] | May | — |
| <span className="hbs-f hbs-e4">[nummerntyp](/en/bo4e/202604/com/Rufnummer#nummerntyp)</span> <AhbTabelle pruefid="13019" format="MSCONS" fv="202604" zeile={43} segment="SG2.NAD+MS.SG4.CTA+IC.COM+[EM\|FX\|TE\|AJ\|AL]" /><span className="hbs-nr">00220</span> | Phone number type | [Enum Rufnummernart](/en/bo4e/202604/enum/Rufnummernart) | Must | — |
| <span className="hbs-w hbs-e5">`RUF_ZENTRALE`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`FAX_ZENTRALE`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`SAMMELRUF`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`SAMMELFAX`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`ABTEILUNGRUF`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`ABTEILUNGFAX`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`RUF_DURCHWAHL`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`FAX_DURCHWAHL`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`MOBIL_NUMMER`</span> | — | — | Must | — |
| <span className="hbs-f hbs-e4">[rufnummer](/en/bo4e/202604/com/Rufnummer#rufnummer)</span> <AhbTabelle pruefid="13019" format="MSCONS" fv="202604" zeile={43} segment="SG2.NAD+MS.SG4.CTA+IC.COM+[EM\|FX\|TE\|AJ\|AL]" /><span className="hbs-nr">00230</span> | rufnummer | string | Must | — |
| <span className="hbs-g hbs-e1">**empfaenger** <span className="hbs-pflicht">\*</span></span> | — | object | Must | — |
| <span className="hbs-f hbs-e2">[rollencodenummer](/en/bo4e/202604/bo/Marktteilnehmer#rollencodenummer) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13019" format="MSCONS" fv="202604" zeile={51} segment="SG2.NAD+MR" /><span className="hbs-nr">00240</span> | Specifies the code value of the market role. | string | X | — |
| <span className="hbs-f hbs-e2">[rollencodetyp](/en/bo4e/202604/bo/Marktteilnehmer#rollencodetyp) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13019" format="MSCONS" fv="202604" zeile={51} segment="SG2.NAD+MR" /><span className="hbs-nr">00250</span> | Indicates the type of the code. | [Enum Rollencodetyp](/en/bo4e/202604/enum/Rollencodetyp) | X | — |
| <span className="hbs-w hbs-e3">`BDEW`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`GS1`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`GLN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`DVGW`</span> | — | — | X | — |

</div>

</Handbuchsatz>

## Application handbook (AHB)

<Handbuchsatz>

<div className="maco-tabellenrahmen" data-maco="ahb-tabelle">

| Structure (EDIFACT) | Description | Format | <span className="hbs-p" title="Energiemenge (Strom)">13019</span> | Condition |
|---|---|---|---|---|
| <span className="hbs-g hbs-e0">**UNB**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`0001 UNOC`</span><span className="hbs-nr">00010</span> | UN/ECE character set C | — | X | — |
| <span className="hbs-f hbs-e1">`0002 3`</span><span className="hbs-nr">00020</span> | Version 3 | — | X | — |
| <span className="hbs-f hbs-e1">`0004`</span><span className="hbs-nr">00030</span> | MP-ID Sender | — | X | — |
| <span className="hbs-f hbs-e1">`0007 14`</span><span className="hbs-nr">00040</span> | GS1 | — | X | — |
| <span className="hbs-f hbs-e1">`0007 500`</span><span className="hbs-nr">00050</span> | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| <span className="hbs-f hbs-e1">`0010`</span><span className="hbs-nr">00060</span> | MP-ID recipient | — | X | — |
| <span className="hbs-f hbs-e1">`0007 14`</span><span className="hbs-nr">00070</span> | GS1 | — | X | — |
| <span className="hbs-f hbs-e1">`0007 500`</span><span className="hbs-nr">00080</span> | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| <span className="hbs-f hbs-e1">`0017`</span><span className="hbs-nr">00090</span> | Date of creation | — | X | — |
| <span className="hbs-f hbs-e1">`0019`</span><span className="hbs-nr">00100</span> | Time of creation | — | X | — |
| <span className="hbs-f hbs-e1">`0020`</span><span className="hbs-nr">00110</span> | Interchange control reference | — | X | <span className="hbs-marke">[918]</span> |
| <span className="hbs-f hbs-e1">`0026 EM`</span><span className="hbs-nr">00120</span> | Energy quantity | — | X | — |
| <span className="hbs-g hbs-e0">**UNH**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`0062`</span><span className="hbs-nr">00130</span> | Message reference number | — | X | — |
| <span className="hbs-f hbs-e1">`0065 MSCONS`</span><span className="hbs-nr">00140</span> | Report on the consumption of measurable services | — | X | — |
| <span className="hbs-f hbs-e1">`0052 D`</span><span className="hbs-nr">00150</span> | Draft version | — | X | — |
| <span className="hbs-f hbs-e1">`0054 04B`</span><span className="hbs-nr">00160</span> | Edition 2004 - B | — | X | — |
| <span className="hbs-f hbs-e1">`0051 UN`</span><span className="hbs-nr">00170</span> | UN/CEFACT | — | X | — |
| <span className="hbs-f hbs-e1">`0057 2.4c`</span><span className="hbs-nr">00180</span> | Version number of the underlying BDEW message description | — | X | — |
| <span className="hbs-g hbs-e0">**BGM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1001 7`</span><span className="hbs-nr">00190</span> | Process data report | — | X | — |
| <span className="hbs-f hbs-e1">`1001 Z41`</span><span className="hbs-nr">00200</span> | Delivery note base price / energy price | — | X | <span className="hbs-marke">[492]</span> ∧ <span className="hbs-marke">[32]</span> ∧ <span className="hbs-marke">[33]</span> |
| <span className="hbs-f hbs-e1">`1004`</span><span className="hbs-nr">00210</span> | Document number | — | X | — |
| <span className="hbs-f hbs-e1">`1225 9`</span><span className="hbs-nr">00220</span> | Original | — | X | — |
| <span className="hbs-g hbs-e0">**DTM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`2005 137`</span><span className="hbs-nr">00230</span> | Document-/message date/time | — | X | — |
| <span className="hbs-f hbs-e1">`2380`</span><span className="hbs-nr">00240</span> | Date or time or time span, value | — | X | <span className="hbs-marke">[931]</span> <span className="hbs-marke">[494]</span> |
| <span className="hbs-f hbs-e1">`2379 303`</span><span className="hbs-nr">00250</span> | CCYYMMDDHHMMZZZ | — | X | — |
| <span className="hbs-g hbs-e0">**SG1.RFF**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1153 AGI`</span><span className="hbs-nr">00260</span> | Application number | — | X | — |
| <span className="hbs-f hbs-e1">`1154`</span><span className="hbs-nr">00270</span> | Reference number | — | X | (<span className="hbs-marke">[529]</span> ∨ <span className="hbs-marke">[553]</span>)  ⊻ (<span className="hbs-marke">[531]</span> ∧ <span className="hbs-marke">[509]</span>) |
| <span className="hbs-g hbs-e0">**SG1.RFF**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1153 Z13`</span><span className="hbs-nr">00280</span> | Check identifier | — | X | — |
| <span className="hbs-f hbs-e1">`1154 13019`</span><span className="hbs-nr">00290</span> | Meter reading value energy quantity (electricity) | — | X | — |
| <span className="hbs-g hbs-e0">**SG2.NAD**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3035 MS`</span><span className="hbs-nr">00300</span> | Document-/message sender or sender | — | X | — |
| <span className="hbs-f hbs-e1">`3039`</span><span className="hbs-nr">00310</span> | MP-ID | — | X | <span className="hbs-marke">[117]</span> |
| <span className="hbs-f hbs-e1">`3055 9`</span><span className="hbs-nr">00320</span> | GS1 | — | X | — |
| <span className="hbs-f hbs-e1">`3055 293`</span><span className="hbs-nr">00330</span> | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| <span className="hbs-g hbs-e0">**SG4.CTA**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3139 IC`</span><span className="hbs-nr">00340</span> | Information point | — | X | — |
| <span className="hbs-f hbs-e1">`3412`</span><span className="hbs-nr">00350</span> | Department or contact person | — | X | — |
| <span className="hbs-g hbs-e0">**SG4.COM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3148`</span><span className="hbs-nr">00360</span> | Communication address, identification | — | X | ((<span className="hbs-marke">[939]</span> <span className="hbs-marke">[142]</span>) ∨ (<span className="hbs-marke">[940]</span> <span className="hbs-marke">[143]</span>)) ∧ <span className="hbs-marke">[576]</span> |
| <span className="hbs-f hbs-e1">`3155 TE`</span><span className="hbs-nr">00370</span> | Telephone | — | X | <span className="hbs-marke">[1P0..1]</span> |
| <span className="hbs-f hbs-e1">`3155 EM`</span><span className="hbs-nr">00380</span> | Email | — | X | <span className="hbs-marke">[1P0..1]</span> |
| <span className="hbs-f hbs-e1">`3155 AJ`</span><span className="hbs-nr">00390</span> | further telephone | — | X | <span className="hbs-marke">[1P0..1]</span> |
| <span className="hbs-f hbs-e1">`3155 AL`</span><span className="hbs-nr">00400</span> | Mobile phone | — | X | <span className="hbs-marke">[1P0..1]</span> |
| <span className="hbs-f hbs-e1">`3155 FX`</span><span className="hbs-nr">00410</span> | Fax number | — | X | <span className="hbs-marke">[1P0..1]</span> |
| <span className="hbs-g hbs-e0">**SG2.NAD**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3035 MR`</span><span className="hbs-nr">00420</span> | Message recipient | — | X | — |
| <span className="hbs-f hbs-e1">`3039`</span><span className="hbs-nr">00430</span> | MP-ID | — | X | <span className="hbs-marke">[117]</span> |
| <span className="hbs-f hbs-e1">`3055 9`</span><span className="hbs-nr">00440</span> | GS1 | — | X | — |
| <span className="hbs-f hbs-e1">`3055 293`</span><span className="hbs-nr">00450</span> | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| <span className="hbs-g hbs-e0">**UNS**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`0081 D`</span><span className="hbs-nr">00460</span> | Separation of header and detail section | — | X | — |
| <span className="hbs-g hbs-e0">**SG5.NAD**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3035 DP`</span><span className="hbs-nr">00470</span> | Supply address | — | X | — |
| <span className="hbs-g hbs-e0">**SG6.LOC**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3227 172`</span><span className="hbs-nr">00480</span> | Reporting point | — | X | — |
| <span className="hbs-f hbs-e1">`3225`</span><span className="hbs-nr">00490</span> | Designation | — | — | M <span className="hbs-marke">[131]</span> ∧ ((<span className="hbs-marke">[951]</span> ∧ <span className="hbs-marke">[510]</span> ∧ <span className="hbs-marke">[522]</span>) ⊻ (<span className="hbs-marke">[950]</span> ∧ <span className="hbs-marke">[514]</span> ∧ (<span className="hbs-marke">[523]</span> ∨ <span className="hbs-marke">[525]</span>))) |
| <span className="hbs-g hbs-e0">**SG7.RFF**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1153 AGK`</span><span className="hbs-nr">00500</span> | Application reference number | — | X | — |
| <span className="hbs-f hbs-e1">`1154`</span><span className="hbs-nr">00510</span> | Configuration ID | — | X | <span className="hbs-marke">[567]</span> |
| <span className="hbs-g hbs-e0">**SG9.LIN**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1082`</span><span className="hbs-nr">00520</span> | Line item number | — | X | <span className="hbs-marke">[908]</span> |
| <span className="hbs-g hbs-e0">**SG9.PIA**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`4347 5`</span><span className="hbs-nr">00530</span> | Product identification | — | X | — |
| <span className="hbs-f hbs-e1">`7140`</span><span className="hbs-nr">00540</span> | Medium / OBIS code number | — | X | (<span className="hbs-marke">[68]</span> ∧ <span className="hbs-marke">[501]</span> ∧ <span className="hbs-marke">[566]</span>) ⊻ (<span className="hbs-marke">[90]</span> ∧ <span className="hbs-marke">[501]</span>) |
| <span className="hbs-f hbs-e1">`7143 SRW`</span><span className="hbs-nr">00550</span> | OBIS code | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.QTY**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`6063 220`</span><span className="hbs-nr">00560</span> | True value | — | X | <span className="hbs-marke">[68]</span> |
| <span className="hbs-f hbs-e1">`6063 67`</span><span className="hbs-nr">00570</span> | Substitute value | — | X | <span className="hbs-marke">[68]</span> ∧ (<span className="hbs-marke">[35]</span> ∨ (<span className="hbs-marke">[32]</span> ∧ <span className="hbs-marke">[77]</span>)) |
| <span className="hbs-f hbs-e1">`6063 Z31`</span><span className="hbs-nr">00580</span> | Entry for the delivery note | — | X | <span className="hbs-marke">[90]</span> |
| <span className="hbs-f hbs-e1">`6060`</span><span className="hbs-nr">00590</span> | Quantity | — | X | (<span className="hbs-marke">[902]</span> ∧ <span className="hbs-marke">[906]</span> <span className="hbs-marke">[46]</span>) ∨ (<span className="hbs-marke">[910]</span> ∧ <span className="hbs-marke">[906]</span> <span className="hbs-marke">[62]</span>) ∨ (<span className="hbs-marke">[910]</span> ∧ <span className="hbs-marke">[906]</span> <span className="hbs-marke">[144]</span>) |
| <span className="hbs-g hbs-e0">**SG10.DTM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`2005 163`</span><span className="hbs-nr">00600</span> | Processing, start date/time | — | X | — |
| <span className="hbs-f hbs-e1">`2380`</span><span className="hbs-nr">00610</span> | Date or time or time span, value | — | X | (((<span className="hbs-marke">[UB1]</span> ∧ <span className="hbs-marke">[119]</span>) ⊻ (<span className="hbs-marke">[931]</span> <span className="hbs-marke">[38]</span>) ⊻ (<span className="hbs-marke">[931]</span> <span className="hbs-marke">[144]</span>)) ∧ <span className="hbs-marke">[495]</span>) |
| <span className="hbs-f hbs-e1">`2379 303`</span><span className="hbs-nr">00620</span> | CCYYMMDDHHMMZZZ | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.DTM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`2005 164`</span><span className="hbs-nr">00630</span> | Processing, end date/time | — | X | — |
| <span className="hbs-f hbs-e1">`2380`</span><span className="hbs-nr">00640</span> | Date or time or time span, value | — | X | (((<span className="hbs-marke">[UB1]</span> ∧ <span className="hbs-marke">[119]</span>) ⊻ (<span className="hbs-marke">[931]</span> <span className="hbs-marke">[38]</span>) ⊻ (<span className="hbs-marke">[931]</span> <span className="hbs-marke">[144]</span>)) ∧ <span className="hbs-marke">[495]</span>) |
| <span className="hbs-f hbs-e1">`2379 303`</span><span className="hbs-nr">00650</span> | CCYYMMDDHHMMZZZ | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.STS**</span> | — | — | Should | (<span className="hbs-marke">[92]</span> ⊻ <span className="hbs-marke">[93]</span>) ∧ <span className="hbs-marke">[126]</span> |
| <span className="hbs-f hbs-e1">`9015 Z33`</span><span className="hbs-nr">00660</span> | Plausibility check note | — | X | — |
| <span className="hbs-f hbs-e1">`9013 Z83`</span><span className="hbs-nr">00670</span> | Customer self-reading | — | X | <span className="hbs-marke">[5P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z84`</span><span className="hbs-nr">00680</span> | Vacancy | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[5P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z85`</span><span className="hbs-nr">00690</span> | Actual meter overflow checked | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[5P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z86`</span><span className="hbs-nr">00700</span> | Plausible due to check reading | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[5P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z87`</span><span className="hbs-nr">00710</span> | Plausible due to customer information | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[5P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZC3`</span><span className="hbs-nr">00720</span> | Exchange of the substitute value | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[5P0..1]</span> |
| <span className="hbs-g hbs-e0">**SG10.STS**</span> | — | — | Must | <span className="hbs-marke">[92]</span> |
| <span className="hbs-f hbs-e1">`9015 Z32`</span><span className="hbs-nr">00730</span> | Substitute value formation procedure | — | X | — |
| <span className="hbs-f hbs-e1">`9013 Z88`</span><span className="hbs-nr">00740</span> | Comparative measurement (calibrated) | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z89`</span><span className="hbs-nr">00750</span> | Comparative measurement (not calibrated) | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z92`</span><span className="hbs-nr">00760</span> | Interpolation | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZJ2`</span><span className="hbs-nr">00770</span> | Statistical method | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZS0`</span><span className="hbs-nr">00780</span> | Substitute value procedure according to the details at the level of the metering location | — | X | <span className="hbs-marke">[46]</span> ∧ <span className="hbs-marke">[568]</span> |
| <span className="hbs-g hbs-e0">**SG10.STS**</span> | — | — | Should | <span className="hbs-marke">[127]</span> ∧ <span className="hbs-marke">[541]</span> |
| <span className="hbs-f hbs-e1">`9015 Z34`</span><span className="hbs-nr">00790</span> | Reason for correction | — | X | — |
| <span className="hbs-f hbs-e1">`9013 Z74`</span><span className="hbs-nr">00800</span> | no access | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z75`</span><span className="hbs-nr">00810</span> | Communication fault | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z76`</span><span className="hbs-nr">00820</span> | Grid outage | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z77`</span><span className="hbs-nr">00830</span> | Voltage failure | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z78`</span><span className="hbs-nr">00840</span> | Device replacement | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z79`</span><span className="hbs-nr">00850</span> | Calibration | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z80`</span><span className="hbs-nr">00860</span> | Device operates outside the operating conditions | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z81`</span><span className="hbs-nr">00870</span> | Measuring equipment faulty/defective | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z82`</span><span className="hbs-nr">00880</span> | Measurement uncertainty | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZA0`</span><span className="hbs-nr">00890</span> | Time set /synchronisation | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZA1`</span><span className="hbs-nr">00900</span> | Meter reading value implausible | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZA3`</span><span className="hbs-nr">00910</span> | Incorrect transformer factor | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[5P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZA4`</span><span className="hbs-nr">00920</span> | Incorrect reading | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[5P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZA5`</span><span className="hbs-nr">00930</span> | Change of the calculation | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[5P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZA6`</span><span className="hbs-nr">00940</span> | Conversion of the metering location | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[5P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZA7`</span><span className="hbs-nr">00950</span> | Data processing error | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[5P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZB0`</span><span className="hbs-nr">00960</span> | Fault / defect of measuring equipment | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[5P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZB9`</span><span className="hbs-nr">00970</span> | Change tariff switching times | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[5P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZC2`</span><span className="hbs-nr">00980</span> | Tariff switching device defective | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[5P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZC4`</span><span className="hbs-nr">00990</span> | Pulse value not sufficient | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZJ8`</span><span className="hbs-nr">01000</span> | Energy quantity in unmetered time interval | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZJ9`</span><span className="hbs-nr">01010</span> | Energy quantity from the unpaired time interval | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[5P0..1]</span> |
| <span className="hbs-g hbs-e0">**SG10.STS**</span> | — | — | Must | <span className="hbs-marke">[92]</span> |
| <span className="hbs-f hbs-e1">`9015 Z40`</span><span className="hbs-nr">01020</span> | Reason for substitute value formation | — | X | — |
| <span className="hbs-f hbs-e1">`9013 Z74`</span><span className="hbs-nr">01030</span> | no access | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z75`</span><span className="hbs-nr">01040</span> | Communication fault | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z76`</span><span className="hbs-nr">01050</span> | Grid outage | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z77`</span><span className="hbs-nr">01060</span> | Voltage failure | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z78`</span><span className="hbs-nr">01070</span> | Device replacement | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z79`</span><span className="hbs-nr">01080</span> | Calibration | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z80`</span><span className="hbs-nr">01090</span> | Device operates outside the operating conditions | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z81`</span><span className="hbs-nr">01100</span> | Measuring equipment faulty/defective | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z82`</span><span className="hbs-nr">01110</span> | Measurement uncertainty | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZA0`</span><span className="hbs-nr">01120</span> | Time set /synchronisation | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZA1`</span><span className="hbs-nr">01130</span> | Meter reading value implausible | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZA3`</span><span className="hbs-nr">01140</span> | Incorrect transformer factor | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZA4`</span><span className="hbs-nr">01150</span> | Incorrect reading | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZA5`</span><span className="hbs-nr">01160</span> | Change of the calculation | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZA6`</span><span className="hbs-nr">01170</span> | Conversion of the metering location | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZA7`</span><span className="hbs-nr">01180</span> | Data processing error | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZB0`</span><span className="hbs-nr">01190</span> | Fault / defect of measuring equipment | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZB9`</span><span className="hbs-nr">01200</span> | Change tariff switching times | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZC2`</span><span className="hbs-nr">01210</span> | Tariff switching device defective | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZC4`</span><span className="hbs-nr">01220</span> | Pulse value not sufficient | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZS9`</span><span className="hbs-nr">01230</span> | Reason for substitute value formation according to the information at metering location level | — | X | <span className="hbs-marke">[46]</span> ∧ <span className="hbs-marke">[570]</span> |
| <span className="hbs-g hbs-e0">**SG10.STS**</span> | — | — | Must | <span className="hbs-marke">[68]</span> ∧ <span className="hbs-marke">[35]</span> ∧ <span className="hbs-marke">[46]</span> ∧ <span className="hbs-marke">[2003]</span> |
| <span className="hbs-f hbs-e1">`9015 10`</span><span className="hbs-nr">01240</span> | Metering classification | — | X | — |
| <span className="hbs-f hbs-e1">`4405 Z36`</span><span className="hbs-nr">01250</span> | Meter reading at the start of the specified energy quantity available and communicated | — | X | <span className="hbs-marke">[83]</span> ∨ (<span className="hbs-marke">[87]</span> ∧ <span className="hbs-marke">[544]</span>) |
| <span className="hbs-f hbs-e1">`4405 Z37`</span><span className="hbs-nr">01260</span> | Meter reading at the end of the specified energy quantity available and communicated | — | X | <span className="hbs-marke">[84]</span> ∨ (<span className="hbs-marke">[88]</span> ∧ <span className="hbs-marke">[545]</span> ∧ <span className="hbs-marke">[577]</span>) |
| <span className="hbs-f hbs-e1">`4405 Z38`</span><span className="hbs-nr">01270</span> | Meter reading at the start of the specified energy quantity not available due to quantity delimitation | — | X | <span className="hbs-marke">[85]</span> |
| <span className="hbs-f hbs-e1">`4405 Z39`</span><span className="hbs-nr">01280</span> | Meter reading at the end of the specified energy quantity not available due to quantity delimitation | — | X | <span className="hbs-marke">[86]</span> |
| <span className="hbs-g hbs-e0">**UNT**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`0074`</span><span className="hbs-nr">01290</span> | Number of segments in a message | — | X | — |
| <span className="hbs-f hbs-e1">`0062`</span><span className="hbs-nr">01300</span> | Message reference number | — | X | — |
| <span className="hbs-g hbs-e0">**UNZ**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`0036`</span><span className="hbs-nr">01310</span> | Interchange counter | — | X | — |
| <span className="hbs-f hbs-e1">`0020`</span><span className="hbs-nr">01320</span> | Interchange control reference | — | X | — |

</div>

</Handbuchsatz>

### Conditions of this table

The free text of the 62 conditions referenced by the rows above. All conditions of the message type are listed in the [condition index MSCONS](/en/referenz/202604/ahb-bedingungen/MSCONS).

<div className="maco-tabellenrahmen">

| Marker | Condition |
|---|---|
| **[32]** | if MP-ID in SG2 NAD+MS in the role NB |
| **[33]** | if MP-ID in SG2 NAD+MR in the role LF |
| **[35]** | if MP-ID in SG2 NAD+MS in the role MSB |
| **[38]** | if the ID of the metering location is stated in SG6 LOC+172 DE3225 |
| **[46]** | If the value in SG6 LOC+172 DE3225 has exactly 11 digits |
| **[62]** | If the value in SG6 LOC+172 DE3225 has exactly 33 digits |
| **[68]** | If BGM+7 present |
| **[77]** | If MP-ID in SG2 NAD+MR of the RB HKN-R |
| **[83]** | If in the same SG9 LIN the entry STS+10+Z38 is not present |
| **[84]** | If in the same SG9 LIN the entry STS+10+Z39 is not present |
| **[85]** | If in the same SG9 LIN the entry STS+10+Z36 is not present |
| **[86]** | If in the same SG9 LIN the entry STS+10+Z37 is not present |
| **[87]** | If the value in DTM+163 DE2380 of the same SG6 LOC+172 with the same value in SG9 PIA+5 DE7140 is the earliest point in time specified |
| **[88]** | If the value in DTM+164 DE2380 of the same SG6 LOC+172 with the same value in SG9 PIA+5 DE7140 is the latest point in time specified |
| **[90]** | If BGM+Z41 present |
| **[92]** | If SG10 QTY DE6063 with value 67 is present |
| **[93]** | If SG10 QTY DE6063 with value 220 is present |
| **[117]** | Only MP-ID from the electricity division |
| **[119]** | if the ID of the market location is stated in SG6 LOC+172 DE3225 |
| **[126]** | if plausibility check notices exist |
| **[127]** | if a correction reason has to be stated |
| **[131]** | if RFF+AGK (configuration ID) is not present |
| **[142]** | if the code EM is present in DE3155 in the same COM |
| **[143]** | if the code TE / FX / AJ / AL is present in DE3155 in the same COM |
| **[144]** | If the value in SG7 RFF+AGK DE1154 (configuration ID) is present |
| **[492]** | If MP-ID in NAD+MR (message recipient) from the Electricity division |
| **[494]** | The date stated here must be the point in time at which the document was created, or a point in time before that. |
| **[495]** | The point in time must be ≤ the value in DE2380 of DTM+137 |
| **[501]** | Note: Only the values that are marked with the corresponding check identifier in the EDI@Energy code list of the OBIS codes and media are permitted. |
| **[509]** | Note: If this is a correction energy quantity, the reference to the MSCONS in which the meter reading was transmitted in advance must be specified here. |
| **[510]** | Note: Use of the ID of the metering location |
| **[514]** | Note: Use of the ID of the market location |
| **[522]** | Note: Only for the transmission of the correction energy quantities in the time interval between two metered values. |
| **[523]** | Note: Only for the transmission of the energy quantity in the time interval between two metered values before the grid usage settlement. |
| **[525]** | Note: Only for the transmission of the energy quantity in the time interval for a market location without a metering location (flat-rate installation) if one of the events from chapter 4.2 has occurred. |
| **[529]** | Note: Value from BGM+7 DE1004 of the ORDERS with which the request for meter reading values was made. |
| **[531]** | Note: Value from BGM+7 DE1004 of the MSCONS with which the meter reading was transmitted. |
| **[541]** | Note: A correction reason is to be specified if: 1. a preliminary value already transmitted to the MP is replaced by a substitute value after cancellation, or 2. a substitute value already transmitted to the MP is replaced by a substitute value after cancellation, or 3. a true value already transmitted to the MP is replaced by a substitute value after cancellation, or 4. a true value already transmitted to the MP is replaced by a true value after cancellation. |
| **[544]** | Note: In the case of a quantity split (e.g. due to a delimitation) for SG6 LOC+172, a meter reading must be available and communicated for every OBIS code for the earliest specified point in time at the start of the time interval (across all repetitions of the LIN segments of the same SG6 LOC+172). |
| **[545]** | Note: In the case of a quantity split (e.g. due to a delimitation) for SG6 LOC+172, a meter reading must be available and communicated for every OBIS code for the latest specified point in time at the end of the time interval (across all repetitions of the LIN segments of the same SG6 LOC+172). |
| **[553]** | Note: Value from BGM+Z34 DE1004 of the ORDERS with which the complaint regarding values was made |
| **[566]** | Note: Only the values that were transmitted by the MSB in the previous master data exchange for this reporting point at the point in time are permitted. |
| **[567]** | Note: The configuration ID that was communicated in the previous master data exchange must be specified. |
| **[568]** | Note: Use is permitted only if it is a 1:n relationship between market and metering location and different substitute value determination procedures have been used and communicated at the level of the metering location. |
| **[570]** | Note: Use is permitted only if it is a 1:n relationship between market and metering location and different reasons for the substitute value determination exist at the level of the metering location and have been communicated. |
| **[576]** | Note: Only one piece of information may be transmitted in DE3148 |
| **[577]** | Note: This code is also to be used if, due to the termination of a metering location (decommissioning), the termination of the market location (decommissioning) takes place at different points in time, that is, the termination of the metering location takes place before the termination of the market location. The energy quantity is to be transmitted up to the end point in time of the market location, even though the last meter reading of the metering location lies at an earlier point in time. |
| **[902]** | Format: Possible value: ≥ 0 |
| **[906]** | Format: max. 3 decimal places |
| **[908]** | Format: possible values: 1 to n |
| **[910]** | Format: Possible value: &lt; 0 or ≥ 0 |
| **[918]** | Format: Characters from the character set defined via UNOC, where only capital letters are permitted among the letters. |
| **[931]** | Format: ZZZ = +00 |
| **[939]** | Format: the character string must contain the characters @ and . |
| **[940]** | Format: the character string must begin with the character + and may only be followed by digits |
| **[950]** | Format: market location ID |
| **[951]** | Format: Metering point identifier |
| **[2003]** | Segment group must be specified exactly two times per SG9 LIN |
| **[1P0..1]** | Note: This is the standard package if no condition applies,  e.g. in the COM segment |
| **[UB1]** | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |
| **[5P0..1]** | [93]  If SG10 QTY DE6063 with value 220 present |
| **[4P0..1]** | [92]  If SG10 QTY DE6063 with value 67 present |

</div>

## Example message

### Example 1

<div data-maco="beispielfall" className="maco-beispielfall">

<Beispielnachricht>

```text title="EDIFACT"
UNA:+.? '
UNB+UNOC:3+9900321000005:500+9903790000002:500+{{date}}:{{time}}+510029++EM'
UNH+621092+MSCONS:D:04B:UN:2.4c'
BGM+Z41+621092BGM+9'
DTM+137:202303291313?+00:303'
RFF+Z13:13019'
NAD+MS+9900321000005::293'
CTA+IC+:Max Mustermann'
COM+max@mustermann.de:EM'
COM+?+012345678920:AJ'
COM+?+012345678940:FX'
COM+?+012345678910:TE'
COM+?+012345678930:AL'
NAD+MR+9903790000002::293'
UNS+D'
NAD+DP'
LOC+172+50074561188'
LIN+1'
PIA+5+1-0?:1.9.0:SRW'
QTY+Z31:2000'
DTM+163:202212312300?+00:303'
DTM+164:202303152300?+00:303'
UNT+21+621092'
UNZ+1+510029'
```

```json title="BO4E-JSON"
[
  {
    "businessKey": "<businessKey>",
    "processDate": null,
    "dataSource": "OUTBOUND",
    "version": 1,
    "edifactVersion": 202604,
    "data": {
      "stammdaten": {
        "ENERGIEMENGE": [
          {
            "boTyp": "ENERGIEMENGE",
            "versionStruktur": "1",
            "lokationsId": "50074561188",
            "lokationsTyp": "MALO",
            "energieverbrauch": [
              {
                "startdatum": "2022-12-31T23:00:00Z",
                "enddatum": "2023-03-15T23:00:00Z",
                "messwertstatus": "ANGABE_FUER_LIEFERSCHEIN",
                "obiskennzahl": "1-0:1.9.0",
                "wert": 2000,
                "position": 1
              }
            ]
          }
        ]
      },
      "transaktionsdaten": {
        "datenaustauschreferenz": "510029",
        "sparte": "STROM",
        "pruefidentifikator": "13019",
        "absender": {
          "boTyp": "MARKTTEILNEHMER",
          "versionStruktur": "1",
          "marktrolle": "NB",
          "rollencodenummer": "9900321000005",
          "rollencodetyp": "BDEW",
          "ansprechpartner": {
            "boTyp": "ANSPRECHPARTNER",
            "versionStruktur": "1",
            "nachname": "Max Mustermann",
            "eMailAdresse": "max@mustermann.de",
            "rufnummern": [
              {
                "nummerntyp": "RUF_ZENTRALE",
                "rufnummer": "+012345678920"
              },
              {
                "nummerntyp": "FAX_DURCHWAHL",
                "rufnummer": "+012345678940"
              },
              {
                "nummerntyp": "RUF_DURCHWAHL",
                "rufnummer": "+012345678910"
              },
              {
                "nummerntyp": "MOBIL_NUMMER",
                "rufnummer": "+012345678930"
              }
            ]
          }
        },
        "empfaenger": {
          "boTyp": "MARKTTEILNEHMER",
          "versionStruktur": "1",
          "marktrolle": "LF",
          "rollencodenummer": "9903790000002",
          "rollencodetyp": "BDEW"
        },
        "dokumentennummer": "621092BGM",
        "kategorie": "Z41",
        "nachrichtenfunktion": "9",
        "nachrichtendatum": "2023-03-29T13:13:00Z",
        "nachrichtenreferenznummer": "621092",
        "typ": "EM"
      },
      "zusatzdaten": {}
    }
  }
]
```

</Beispielnachricht>

*Source: [`1.edi`](https://github.com/conuti-gmbh/maco-edi-testfiles/blob/main/inbound/v202604/mscons/13019/1.edi) · [`1.json`](https://github.com/conuti-gmbh/maco-edi-testfiles/blob/main/outbound/v202604/mscons/13019/1.json)*

<Testdateien edi="/testdaten/202604/mscons/13019/1.edi" json="/testdaten/202604/mscons/13019/1.json" />

</div>

### Example 2

<div data-maco="beispielfall" className="maco-beispielfall">

<Beispielnachricht>

```text title="EDIFACT"
UNA:+.? '
UNB+UNOC:3+9904446000007:500+9900321000005:500+{{date}}:{{time}}+177706++EM'
UNH+039126+MSCONS:D:04B:UN:2.4c'
BGM+7+039126BGM+9'
DTM+137:202303291323?+00:303'
RFF+AGI:REF12345678910'
RFF+Z13:13019'
NAD+MS+9904446000007::293'
NAD+MR+9900321000005::293'
UNS+D'
NAD+DP'
LOC+172+DE0032106765712000000000000000037'
LIN+1'
PIA+5+1-0?:1.8.0:SRW'
QTY+67:2000'
DTM+163:202212312300?+00:303'
DTM+164:202303152300?+00:303'
STS+Z32++Z92'
STS+Z40++Z74'
UNT+18+039126'
UNZ+1+177706'
```

```json title="BO4E-JSON"
[
  {
    "businessKey": "<businessKey>",
    "processDate": null,
    "dataSource": "OUTBOUND",
    "version": 1,
    "edifactVersion": 202604,
    "data": {
      "stammdaten": {
        "ENERGIEMENGE": [
          {
            "boTyp": "ENERGIEMENGE",
            "versionStruktur": "1",
            "lokationsId": "DE0032106765712000000000000000037",
            "lokationsTyp": "MELO",
            "energieverbrauch": [
              {
                "startdatum": "2022-12-31T23:00:00Z",
                "enddatum": "2023-03-15T23:00:00Z",
                "messwertstatus": "ERSATZWERT",
                "statuszusatzinformationen": [
                  {
                    "art": "ERSATZWERTBILDUNGSVERFAHREN",
                    "status": "INTERPOLATION"
                  },
                  {
                    "art": "GRUND_ERSATZWERTBILDUNGSVERFAHREN",
                    "status": "KEIN_ZUGANG"
                  }
                ],
                "obiskennzahl": "1-0:1.8.0",
                "wert": 2000,
                "position": 1
              }
            ]
          }
        ]
      },
      "transaktionsdaten": {
        "datenaustauschreferenz": "177706",
        "sparte": "STROM",
        "pruefidentifikator": "13019",
        "absender": {
          "boTyp": "MARKTTEILNEHMER",
          "versionStruktur": "1",
          "marktrolle": "MSB",
          "rollencodenummer": "9904446000007",
          "rollencodetyp": "BDEW"
        },
        "empfaenger": {
          "boTyp": "MARKTTEILNEHMER",
          "versionStruktur": "1",
          "rollencodenummer": "9900321000005",
          "rollencodetyp": "BDEW"
        },
        "dokumentennummer": "039126BGM",
        "kategorie": "7",
        "nachrichtenfunktion": "9",
        "nachrichtendatum": "2023-03-29T13:23:00Z",
        "nachrichtenreferenznummer": "039126",
        "typ": "EM",
        "anfrageReferenz": "REF12345678910"
      },
      "zusatzdaten": {}
    }
  }
]
```

</Beispielnachricht>

*Source: [`2.edi`](https://github.com/conuti-gmbh/maco-edi-testfiles/blob/main/inbound/v202604/mscons/13019/2.edi) · [`2.json`](https://github.com/conuti-gmbh/maco-edi-testfiles/blob/main/outbound/v202604/mscons/13019/2.json)*

<Testdateien edi="/testdaten/202604/mscons/13019/2.edi" json="/testdaten/202604/mscons/13019/2.json" />

</div>

## Belongs to these role views

The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are **LF**, **NB**, **MSB** and **ÜNB**.

<div className="maco-tabellenrahmen">

| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | [Transmission of the delivery note for grid usage settlement](/en/prozessdoku/202604/LF/GPKE-Teil2-uebermittlung-des-lieferscheins-zur-netznutzungsabrechnung) | GPKE part 2 | Electricity | Step 1 |
| LF | LF | [Business data request](/en/prozessdoku/202604/LF/GPKE-Teil4-geschaeftsdatenanfrage) | GPKE part 4 | Electricity | Step 4 |
| LF | LF | [Processing and transmission of values from the MSB of the market location](/en/prozessdoku/202604/LF/WiM-Teil2-aufbereitung-und-uebermittlung-von-werten-vom-msb-der-marktlokation) | WiM electricity part 2 | Electricity | Step 1 |
| LF | LF | [Processing and transmission of values from the MSB of the market location](/en/prozessdoku/202604/LF/WiM-Teil2-aufbereitung-und-uebermittlung-von-werten-vom-msb-der-marktlokation) | WiM electricity part 2 | Electricity | Step 2 |
| NB | NB | [Transmission of the delivery note for grid usage settlement](/en/prozessdoku/202604/NB/GPKE-Teil2-uebermittlung-des-lieferscheins-zur-netznutzungsabrechnung) | GPKE part 2 | Electricity | Step 1 |
| NB | NB | [Business data request](/en/prozessdoku/202604/NB/GPKE-Teil4-geschaeftsdatenanfrage) | GPKE part 4 | Electricity | Step 4 |
| NB | NB | [Processing and transmission of values from the MSB of the market location](/en/prozessdoku/202604/NB/WiM-Teil2-aufbereitung-und-uebermittlung-von-werten-vom-msb-der-marktlokation) | WiM electricity part 2 | Electricity | Step 1 |
| NB | NB | [Processing and transmission of values from the MSB of the market location](/en/prozessdoku/202604/NB/WiM-Teil2-aufbereitung-und-uebermittlung-von-werten-vom-msb-der-marktlokation) | WiM electricity part 2 | Electricity | Step 2 |
| MSB | MSB | [Business data request](/en/prozessdoku/202604/MSB/GPKE-Teil4-geschaeftsdatenanfrage) | GPKE part 4 | Electricity | Step 4 |
| MSB | MSB-MALO | [Processing and transmission of values from the MSB of the market location](/en/prozessdoku/202604/MSB/WiM-Teil2-aufbereitung-und-uebermittlung-von-werten-vom-msb-der-marktlokation) | WiM electricity part 2 | Electricity | Step 1 |
| MSB | MSB-MALO | [Processing and transmission of values from the MSB of the market location](/en/prozessdoku/202604/MSB/WiM-Teil2-aufbereitung-und-uebermittlung-von-werten-vom-msb-der-marktlokation) | WiM electricity part 2 | Electricity | Step 2 |
| ÜNB | ÜNB | [Processing and transmission of values from the MSB of the market location](/en/prozessdoku/202604/UENB/WiM-Teil2-aufbereitung-und-uebermittlung-von-werten-vom-msb-der-marktlokation) | WiM electricity part 2 | Electricity | Step 1 |
| ÜNB | ÜNB | [Processing and transmission of values from the MSB of the market location](/en/prozessdoku/202604/UENB/WiM-Teil2-aufbereitung-und-uebermittlung-von-werten-vom-msb-der-marktlokation) | WiM electricity part 2 | Electricity | Step 2 |

</div>

## Business classification

<div className="maco-tabellenrahmen">

| Attribute | Value |
|---|---|
| Use case (AHB) | Energy quantity (electricity) |
| AHB | MSCONS AHB |
| Transmission channel | MP |

</div>

:::caution{title="This check identifier is used in 7 contexts"}

Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.

:::

<div className="maco-tabellenrahmen">

| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| Processes for the exchange of information between grid operator and the guarantee of origin register (HKN-R) of the Federal Environment Agency (UBA) | Ch. 2.3 No. 5 | NB → RB HKN-R | Response to meter reading values subscription |
| Processes for the exchange of information between grid operator and the guarantee of origin register (HKN-R) of the Federal Environment Agency (UBA) | Ch. 2.4 Case 2 No. 4 | NB → RB HKN-R | Response to meter reading values subscription |
| GPKE part 2 | Transmission of the delivery note for the grid usage settlement | NB → LF | Delivery note |
| GPKE part 4 | Business data request | MSB → LF | Response |
| WiM electricity part 2 | Processing and transmission of values from the MSB of the market location | MSB (corresponds to the MSB on the object market location) → NB | Value (market location / metering location) at NB |
| WiM electricity part 2 | Processing and transmission of values from the MSB of the market location | MSB (corresponds to the MSB on the object market location) → LF | Value (market location / metering location) at LF |
| GPKE part 4 | Business data request | MSB → NB | Response |

</div>

## Transaction and responses

**Role of this check identifier: response.** Basis: the title or the action of the Prüfi table begins with “response”. The title names **no** polarity — whether this message confirms or rejects is decided by the response code, not by the check identifier.

### Which request this message responds to

<div className="maco-tabellenrahmen">

| Role | Check identifier | Use case | Message type | Origin of supply |
|---|---|---|---|---|
| Request | [17102](/schnittstellen/202604/pruefi/ORDERS/PI_17102) | Request for values | ORDERS | from the step sequence |

</div>

### In which field the request is quoted

<div className="maco-tabellenrahmen">

| Reference field of this message | EDIFACT segment | Target field in the request |
|---|---|---|
| `anfrageReferenz` | `SG1.RFF+AGI` | `dokumentennummer` |

</div>

RFF+AGI quotes the `BGM` of the request; the target is its `dokumentennummer`. Measured: 17102 carries `dokumentennummer` in `BGM+[7|Z28|Z48]`.

**Check identifiers of the same AHB table:** No other check identifier of message type MSCONS has the same row structure in this version.

<Hinweisbereich>

An **\*** after a field or group name marks a **mandatory field** or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.

The status column carries two vocabularies because the manual answers two questions: on a **group row**, *Muss*, *Soll* or *Kann* states whether the EDIFACT segment must be present; on a **field row**, *X* states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.

For this check identifier, the application handbook lists **158 rows**. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.

The **Condition** column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.

The test data contains 2 transactions for this check identifier under the message type `mscons`. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.

:::note{title="Placeholder from the test data set"}

The test data set carries placeholders instead of valid values: `{{date}}` and `{{time}}` in the UNB interchange envelope of every EDIFACT file. **The page replaces these on call with the current date and the current time** — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.

`<businessKey>` stays in place. It is not a time value, and an invented key would look like a valid one.

:::

</Hinweisbereich>