# Check identifier 55062 — Activation of ZP

<span hidden data-pagefind-meta={"title:Check identifier 55062 — Activation of ZP · UTILMD · Format version 202604"} />

Check identifier **55062** · EDIFACT message type **UTILMD** · Format version **202604**

:::info{title="This page is derived from the application handbook"}

The MACO APP does not carry this check identifier. The complete Prüfi pages of this level are produced from the specifications of the application — one class in the templater per check identifier — and that is where the **assignment to the business objects (BO4E)** comes from: which object carries which field of the message.

The catalogue of the application handbook is the larger set. This page therefore shows what the handbook itself provides — use case, process context and the AHB field list with its conditions. A data structure according to BO4E is not shown, and not because there is none, but because the application does not form one for this check identifier.

All check identifiers in this situation — and the corresponding figures — are listed by [the overview of this version](/en/schnittstellen/202604/pruefi/nicht-gefuehrt).

:::

## Application handbook (AHB)

<Handbuchsatz>

<div className="maco-tabellenrahmen" data-maco="ahb-tabelle">

| Structure (EDIFACT) | Description | Format | <span className="hbs-p" title="Aktivierung von ZP">55062</span> | Condition |
|---|---|---|---|---|
| <span className="hbs-g hbs-e0">**UNH**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`0062`</span><span className="hbs-nr">00010</span> | Message reference number | — | X | — |
| <span className="hbs-f hbs-e1">`0065 UTILMD`</span><span className="hbs-nr">00020</span> | Grid connection master data | — | X | — |
| <span className="hbs-f hbs-e1">`0052 D`</span><span className="hbs-nr">00030</span> | Draft version | — | X | — |
| <span className="hbs-f hbs-e1">`0054 11A`</span><span className="hbs-nr">00040</span> | Edition 2011 - A | — | X | — |
| <span className="hbs-f hbs-e1">`0051 UN`</span><span className="hbs-nr">00050</span> | UN/CEFACT | — | X | — |
| <span className="hbs-f hbs-e1">`0057 S2.1`</span><span className="hbs-nr">00060</span> | Version number of the underlying BDEW message description | — | X | — |
| <span className="hbs-g hbs-e0">**BGM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1001 Z07`</span><span className="hbs-nr">00070</span> | Activation/ deactivation of MaBiS-ZP | — | X | — |
| <span className="hbs-f hbs-e1">`1004`</span><span className="hbs-nr">00080</span> | Document number | — | X | — |
| <span className="hbs-g hbs-e0">**DTM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`2005 137`</span><span className="hbs-nr">00090</span> | Document-/message date/time | — | X | — |
| <span className="hbs-f hbs-e1">`2380`</span><span className="hbs-nr">00100</span> | Date or time or time span, value | — | X | <span className="hbs-marke">[931]</span> <span className="hbs-marke">[494]</span> |
| <span className="hbs-f hbs-e1">`2379 303`</span><span className="hbs-nr">00110</span> | CCYYMMDDHHMMZZZ | — | X | — |
| <span className="hbs-g hbs-e0">**SG2.NAD**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3035 MS`</span><span className="hbs-nr">00120</span> | Document-/message sender or sender | — | X | — |
| <span className="hbs-f hbs-e1">`3039`</span><span className="hbs-nr">00130</span> | MP-ID | — | X | — |
| <span className="hbs-f hbs-e1">`3055 9`</span><span className="hbs-nr">00140</span> | GS1 | — | X | — |
| <span className="hbs-f hbs-e1">`3055 293`</span><span className="hbs-nr">00150</span> | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| <span className="hbs-g hbs-e0">**SG3.CTA**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3139 IC`</span><span className="hbs-nr">00160</span> | Information contact | — | X | — |
| <span className="hbs-f hbs-e1">`3412`</span><span className="hbs-nr">00170</span> | Name of the contact person | — | X | — |
| <span className="hbs-g hbs-e0">**SG3.COM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3148`</span><span className="hbs-nr">00180</span> | Number / address | — | X | ((<span className="hbs-marke">[939]</span> <span className="hbs-marke">[321]</span>) ∨ (<span className="hbs-marke">[940]</span> <span className="hbs-marke">[322]</span>)) ∧ <span className="hbs-marke">[514]</span> |
| <span className="hbs-f hbs-e1">`3155 EM`</span><span className="hbs-nr">00190</span> | Electronic mail | — | X | <span className="hbs-marke">[1P0..1]</span> |
| <span className="hbs-f hbs-e1">`3155 FX`</span><span className="hbs-nr">00200</span> | Fax number | — | X | <span className="hbs-marke">[1P0..1]</span> |
| <span className="hbs-f hbs-e1">`3155 TE`</span><span className="hbs-nr">00210</span> | Telephone | — | X | <span className="hbs-marke">[1P0..1]</span> |
| <span className="hbs-f hbs-e1">`3155 AJ`</span><span className="hbs-nr">00220</span> | further telephone | — | X | <span className="hbs-marke">[1P0..1]</span> |
| <span className="hbs-f hbs-e1">`3155 AL`</span><span className="hbs-nr">00230</span> | Mobile phone | — | X | <span className="hbs-marke">[1P0..1]</span> |
| <span className="hbs-g hbs-e0">**SG2.NAD**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3035 MR`</span><span className="hbs-nr">00240</span> | Message recipient | — | X | — |
| <span className="hbs-f hbs-e1">`3039`</span><span className="hbs-nr">00250</span> | MP-ID | — | X | <span className="hbs-marke">[280]</span> |
| <span className="hbs-f hbs-e1">`3055 9`</span><span className="hbs-nr">00260</span> | GS1 | — | X | — |
| <span className="hbs-f hbs-e1">`3055 293`</span><span className="hbs-nr">00270</span> | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| <span className="hbs-g hbs-e0">**SG4.IDE**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7495 24`</span><span className="hbs-nr">00280</span> | Transaction | — | X | — |
| <span className="hbs-f hbs-e1">`7402`</span><span className="hbs-nr">00290</span> | Transaction number | — | X | — |
| <span className="hbs-g hbs-e0">**SG4.DTM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`2005 158`</span><span className="hbs-nr">00300</span> | Start of balancing | — | X | — |
| <span className="hbs-f hbs-e1">`2380`</span><span className="hbs-nr">00310</span> | Date or time or time span, value | — | X | <span className="hbs-marke">[UB1]</span> |
| <span className="hbs-f hbs-e1">`2379 303`</span><span className="hbs-nr">00320</span> | CCYYMMDDHHMMZZZ | — | X | — |
| <span className="hbs-g hbs-e0">**SG5.LOC**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3227 Z15`</span><span className="hbs-nr">00330</span> | MaBiS metering point | — | X | — |
| <span className="hbs-f hbs-e1">`3225`</span><span className="hbs-nr">00340</span> | Identifier | — | X | <span className="hbs-marke">[951]</span> |
| <span className="hbs-g hbs-e0">**SG6.RFF**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1153 Z13`</span><span className="hbs-nr">00350</span> | Check identifier | — | X | — |
| <span className="hbs-f hbs-e1">`1154 55062`</span><span className="hbs-nr">00360</span> | MaBiS / activation of MaBiS-ZP | — | X | — |
| <span className="hbs-g hbs-e0">**SG8.SEQ**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1229 Z22`</span><span className="hbs-nr">00370</span> | Data of the aggregated time series | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7037 ZB4`</span><span className="hbs-nr">00380</span> | Designation of the aggregated time series | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CAV**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7111 Z95`</span><span className="hbs-nr">00390</span> | BG-SZR (category B) | — | X | — |
| <span className="hbs-f hbs-e1">`7111 Z96`</span><span className="hbs-nr">00400</span> | BG-SZR (category C) | — | X | — |
| <span className="hbs-f hbs-e1">`7111 Z97`</span><span className="hbs-nr">00410</span> | BK-SZR (category A) | — | X | — |
| <span className="hbs-f hbs-e1">`7111 Z98`</span><span className="hbs-nr">00420</span> | BK-SZR (category B) at control area level | — | X | — |
| <span className="hbs-f hbs-e1">`7111 Z99`</span><span className="hbs-nr">00430</span> | BK-SZR (category B) at balancing area level | — | X | — |
| <span className="hbs-f hbs-e1">`7111 ZA0`</span><span className="hbs-nr">00440</span> | BK-SZR (category C) | — | X | — |
| <span className="hbs-f hbs-e1">`7111 ZA1`</span><span className="hbs-nr">00450</span> | LF-SZR (category A) | — | X | — |
| <span className="hbs-f hbs-e1">`7111 ZA2`</span><span className="hbs-nr">00460</span> | LF-SZR (category B) at control area level | — | X | — |
| <span className="hbs-f hbs-e1">`7111 ZA3`</span><span className="hbs-nr">00470</span> | LF-SZR (category B) at balancing area level | — | X | — |
| <span className="hbs-f hbs-e1">`7111 ZA4`</span><span className="hbs-nr">00480</span> | Delta time series carry-over (DZÜ) | — | X | — |
| <span className="hbs-f hbs-e1">`7111 ZA5`</span><span className="hbs-nr">00490</span> | Grid time series (NZR) | — | X | — |
| <span className="hbs-f hbs-e1">`7111 ZA6`</span><span className="hbs-nr">00500</span> | Settlement aggregated time series | — | X | — |
| <span className="hbs-f hbs-e1">`7111 ZG7`</span><span className="hbs-nr">00510</span> | BK-SZR (eMob, daily) | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7059 6`</span><span className="hbs-nr">00520</span> | Responsible party | — | X | — |
| <span className="hbs-f hbs-e1">`7037 ZA8`</span><span className="hbs-nr">00530</span> | NB | — | X | — |
| <span className="hbs-f hbs-e1">`7037 ZA9`</span><span className="hbs-nr">00540</span> | ÜNB | — | X | — |
| <span className="hbs-f hbs-e1">`7037 ZB7`</span><span className="hbs-nr">00550</span> | BIKO | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7059 Z18`</span><span className="hbs-nr">00560</span> | Control area | — | X | — |
| <span className="hbs-f hbs-e1">`7037`</span><span className="hbs-nr">00570</span> | Control area | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7059 Z20`</span><span className="hbs-nr">00580</span> | Balancing area | — | X | — |
| <span className="hbs-f hbs-e1">`7037`</span><span className="hbs-nr">00590</span> | Balancing area | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7059 Z19`</span><span className="hbs-nr">00600</span> | Balancing group | — | X | — |
| <span className="hbs-f hbs-e1">`7037`</span><span className="hbs-nr">00610</span> | Balancing group | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7059 15`</span><span className="hbs-nr">00620</span> | Structure | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z21`</span><span className="hbs-nr">00630</span> | Aggregated time series type | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CAV**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7111`</span><span className="hbs-nr">00640</span> | Code of the time series type | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7037 ZB6`</span><span className="hbs-nr">00650</span> | Reference time period of the aggregated time series | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CAV**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7111 Z94`</span><span className="hbs-nr">00660</span> | Month | — | X | <span className="hbs-marke">[340]</span> |
| <span className="hbs-f hbs-e1">`7111 Z93`</span><span className="hbs-nr">00670</span> | Day | — | X | <span className="hbs-marke">[341]</span> |
| <span className="hbs-g hbs-e0">**SG10.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7037 ZB5`</span><span className="hbs-nr">00680</span> | Voltage level of the aggregated time series | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CAV**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7111 E03`</span><span className="hbs-nr">00690</span> | Extra-high voltage | — | X | — |
| <span className="hbs-f hbs-e1">`7111 E04`</span><span className="hbs-nr">00700</span> | High voltage | — | X | — |
| <span className="hbs-f hbs-e1">`7111 E05`</span><span className="hbs-nr">00710</span> | Medium voltage | — | X | — |
| <span className="hbs-f hbs-e1">`7111 E06`</span><span className="hbs-nr">00720</span> | Low voltage | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CAV**</span> | — | — | Should | <span className="hbs-marke">[166]</span> |
| <span className="hbs-f hbs-e1">`7111 E07`</span><span className="hbs-nr">00730</span> | EHV/HV transformation | — | X | <span className="hbs-marke">[195]</span> |
| <span className="hbs-f hbs-e1">`7111 E08`</span><span className="hbs-nr">00740</span> | HV/MV transformation | — | X | <span className="hbs-marke">[194]</span> |
| <span className="hbs-f hbs-e1">`7111 E09`</span><span className="hbs-nr">00750</span> | MS/NS transformation | — | X | <span className="hbs-marke">[193]</span> |
| <span className="hbs-g hbs-e0">**SG8.SEQ**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1229 Z23`</span><span className="hbs-nr">00760</span> | Product data of the aggregated time series | — | X | — |
| <span className="hbs-g hbs-e0">**SG8.PIA**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`4347 5`</span><span className="hbs-nr">00770</span> | Product identification | — | X | — |
| <span className="hbs-f hbs-e1">`7140`</span><span className="hbs-nr">00780</span> | Product identification of the aggregated time series | — | X | — |
| <span className="hbs-f hbs-e1">`7143 SRW`</span><span className="hbs-nr">00790</span> | OBIS code | — | X | — |
| <span className="hbs-g hbs-e0">**UNT**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`0074`</span><span className="hbs-nr">00800</span> | Number of segments in a message | — | X | — |
| <span className="hbs-f hbs-e1">`0062`</span><span className="hbs-nr">00810</span> | Message reference number | — | X | — |

</div>

</Handbuchsatz>

### Conditions of this table

The free text of the 17 conditions referenced by the rows above. All conditions of the message type are listed in the [condition index UTILMDS](/en/referenz/202604/ahb-bedingungen/UTILMDS).

<div className="maco-tabellenrahmen">

| Marker | Condition |
|---|---|
| **[166]** | If present |
| **[193]** | If the SG10 CCI ZB5 (voltage level of the aggregated time series) CAV E06 (low voltage) is present in this SG |
| **[194]** | If the SG10 CCI ZB5 (voltage level of the aggregated time series) CAV E05 (medium voltage) is present in this SG |
| **[195]** | If the SG10 CCI ZB5 (voltage level of the aggregated time series) CAV E04 (high voltage) is present in this SG |
| **[280]** | Only MP-ID from the electricity division |
| **[321]** | If code EM is present in DE3155 in the same COM |
| **[322]** | If code TE / FX / AJ / AL is present in DE3155 in the same COM |
| **[340]** | If CCI+++ZB4 (designation of the aggregated time series) CAV+Z95/Z97/Z98/Z99/ZA1/ZA2/ZA3/ZA4/ZA5/ZA6 present |
| **[341]** | If CCI+++ZB4 (designation of the aggregated time series) CAV+Z96/ZA0/ZG7 present |
| **[494]** | The date stated here must be the point in time at which the document was created, or a point in time before that |
| **[514]** | Note: Only one piece of information may be transmitted in DE3148 |
| **[931]** | Format: ZZZ = +00 |
| **[939]** | Format: the character string must contain the characters @ and . |
| **[940]** | Format: the character string must begin with the character + and may only be followed by digits |
| **[951]** | Format: Metering point identifier |
| **[1P0..1]** | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
| **[UB1]** | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |

</div>

## Belongs to these role views

The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are **LF**, **NB**, **ÜNB**, **BIKO** and **BKV**.

<div className="maco-tabellenrahmen">

| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | [Activation of a MaBiS metering point for the supplier aggregated time series from the NB to LF](/en/prozessdoku/202604/LF/MaBiS-aktivierung-eines-mabis-zaehlpunkts-fuer-die-lieferantensummenzeitreihe-vom-nb-an-lf) | MaBiS | Electricity | Step 1 |
| LF | LF | [Activation of a MaBiS metering point for the supplier aggregated time series from the ÜNB to LF](/en/prozessdoku/202604/LF/MaBiS-aktivierung-eines-mabis-zaehlpunkts-fuer-die-lieferantensummenzeitreihe-vom-uenb-an-lf) | MaBiS | Electricity | Step 1 |
| NB | LPB | [Activation of a MaBiS metering point for the daily balancing group aggregated time series eMob from the NB (LPB) to ÜNB](/en/prozessdoku/202604/NB/awh-modell-2-ladev-scharf-bila-energie-zuord-moglichkeit-aktivierung-eines-mabis-zahlpunkts-fur-die-tagliche-bilanzkreissummenzeitreihe-emob-vom-nb-lpb-an-unb) | AWH Model 2 charg.-session-level bal. energy assign. option | Electricity | Step 1 |
| NB | NB | [Activation of a MaBiS metering point for the delta time series carry-over from the ÜNB to BIKO and NB](/en/prozessdoku/202604/NB/MaBiS-aktivierung-eines-mabis-zaehlpunkts-fuer-den-deltazeitreihenuebertrag-vom-uenb-an-biko-und-nb) | MaBiS | Electricity | Step 1 |
| NB | NB | [Activation of a MaBiS metering point for the delta time series carry-over from the ÜNB to BIKO and NB](/en/prozessdoku/202604/NB/MaBiS-aktivierung-eines-mabis-zaehlpunkts-fuer-den-deltazeitreihenuebertrag-vom-uenb-an-biko-und-nb) | MaBiS | Electricity | Step 4 |
| NB | NB | [Activation of a MaBiS metering point for the settlement aggregated time series from the BIKO to NB](/en/prozessdoku/202604/NB/MaBiS-aktivierung-eines-mabis-zaehlpunkts-fuer-die-abrechnungssummenzeitreihe-vom-biko-an-nb) | MaBiS | Electricity | Step 1 |
| NB | NB | [Activation of a MaBiS metering point for the balancing area aggregate time series from the ÜNB to BIKO and NB](/en/prozessdoku/202604/NB/MaBiS-aktivierung-eines-mabis-zaehlpunkts-fuer-die-bilanzierungsgebietssummenzeitreihe-vom-uenb-an-biko-und-nb) | MaBiS | Electricity | Step 1 |
| NB | NB | [Activation of a MaBiS metering point for the balancing area aggregate time series from the ÜNB to BIKO and NB](/en/prozessdoku/202604/NB/MaBiS-aktivierung-eines-mabis-zaehlpunkts-fuer-die-bilanzierungsgebietssummenzeitreihe-vom-uenb-an-biko-und-nb) | MaBiS | Electricity | Step 4 |
| NB | NB | [Activation of a MaBiS metering point for the balancing group aggregated time series from the NB to BIKO and BKV](/en/prozessdoku/202604/NB/MaBiS-aktivierung-eines-mabis-zaehlpunkts-fuer-die-bilanzkreissummenzeitreihe-vom-nb-an-biko-und-bkv) | MaBiS | Electricity | Step 1 |
| NB | NB | [Activation of a MaBiS metering point for the balancing group aggregated time series from the NB to BIKO and BKV](/en/prozessdoku/202604/NB/MaBiS-aktivierung-eines-mabis-zaehlpunkts-fuer-die-bilanzkreissummenzeitreihe-vom-nb-an-biko-und-bkv) | MaBiS | Electricity | Step 4 |
| NB | NB | [Activation of a MaBiS metering point for the supplier aggregated time series from the NB to LF](/en/prozessdoku/202604/NB/MaBiS-aktivierung-eines-mabis-zaehlpunkts-fuer-die-lieferantensummenzeitreihe-vom-nb-an-lf) | MaBiS | Electricity | Step 1 |
| NB | NB | [Activation of a MaBiS metering point for the daily balancing area aggregate time series from the ÜNB to NB](/en/prozessdoku/202604/NB/MaBiS-aktivierung-eines-mabis-zaehlpunkts-fuer-die-taegliche-bilanzierungsgebietssummenzeitreihe-vom-uenb-an-nb) | MaBiS | Electricity | Step 1 |
| NB | NBB | [Activation of a MaBiS metering point for the grid time series](/en/prozessdoku/202604/NB--NBB/MaBiS-aktivierung-eines-mabis-zaehlpunkts-fuer-die-netzzeitreihe) | MaBiS | Electricity | Step 1 |
| NB | NBB | [Activation of a MaBiS metering point for the grid time series](/en/prozessdoku/202604/NB--NBB/MaBiS-aktivierung-eines-mabis-zaehlpunkts-fuer-die-netzzeitreihe) | MaBiS | Electricity | Step 4 |
| NB | NBV | [Activation of a MaBiS metering point for the grid time series](/en/prozessdoku/202604/NB--NBV/MaBiS-aktivierung-eines-mabis-zaehlpunkts-fuer-die-netzzeitreihe) | MaBiS | Electricity | Step 1 |
| NB | NBV | [Activation of a MaBiS metering point for the grid time series](/en/prozessdoku/202604/NB--NBV/MaBiS-aktivierung-eines-mabis-zaehlpunkts-fuer-die-netzzeitreihe) | MaBiS | Electricity | Step 4 |
| ÜNB | ÜNB | [Activation of a MaBiS metering point for the daily balancing group aggregated time series eMob from the NB (LPB) to ÜNB](/en/prozessdoku/202604/UENB/awh-modell-2-ladev-scharf-bila-energie-zuord-moglichkeit-aktivierung-eines-mabis-zahlpunkts-fur-die-tagliche-bilanzkreissummenzeitreihe-emob-vom-nb-lpb-an-unb) | AWH Model 2 charg.-session-level bal. energy assign. option | Electricity | Step 1 |
| ÜNB | ÜNB | [Activation of a MaBiS metering point for the delta time series carry-over from the ÜNB to BIKO and NB](/en/prozessdoku/202604/UENB/MaBiS-aktivierung-eines-mabis-zaehlpunkts-fuer-den-deltazeitreihenuebertrag-vom-uenb-an-biko-und-nb) | MaBiS | Electricity | Step 1 |
| ÜNB | ÜNB | [Activation of a MaBiS metering point for the delta time series carry-over from the ÜNB to BIKO and NB](/en/prozessdoku/202604/UENB/MaBiS-aktivierung-eines-mabis-zaehlpunkts-fuer-den-deltazeitreihenuebertrag-vom-uenb-an-biko-und-nb) | MaBiS | Electricity | Step 4 |
| ÜNB | ÜNB | [Activation of a MaBiS metering point for the settlement aggregated time series from the BIKO to ÜNB](/en/prozessdoku/202604/UENB/MaBiS-aktivierung-eines-mabis-zaehlpunkts-fuer-die-abrechnungssummenzeitreihe-vom-biko-an-uenb) | MaBiS | Electricity | Step 1 |
| ÜNB | ÜNB | [Activation of a MaBiS metering point for the balancing area aggregate time series from the ÜNB to BIKO and NB](/en/prozessdoku/202604/UENB/MaBiS-aktivierung-eines-mabis-zaehlpunkts-fuer-die-bilanzierungsgebietssummenzeitreihe-vom-uenb-an-biko-und-nb) | MaBiS | Electricity | Step 1 |
| ÜNB | ÜNB | [Activation of a MaBiS metering point for the balancing area aggregate time series from the ÜNB to BIKO and NB](/en/prozessdoku/202604/UENB/MaBiS-aktivierung-eines-mabis-zaehlpunkts-fuer-die-bilanzierungsgebietssummenzeitreihe-vom-uenb-an-biko-und-nb) | MaBiS | Electricity | Step 4 |
| ÜNB | ÜNB | [Activation of a MaBiS metering point for the balancing group aggregated time series from the ÜNB to BIKO and BKV](/en/prozessdoku/202604/UENB/MaBiS-aktivierung-eines-mabis-zaehlpunkts-fuer-die-bilanzkreissummenzeitreihe-vom-uenb-an-biko-und-bkv) | MaBiS | Electricity | Step 1 |
| ÜNB | ÜNB | [Activation of a MaBiS metering point for the balancing group aggregated time series from the ÜNB to BIKO and BKV](/en/prozessdoku/202604/UENB/MaBiS-aktivierung-eines-mabis-zaehlpunkts-fuer-die-bilanzkreissummenzeitreihe-vom-uenb-an-biko-und-bkv) | MaBiS | Electricity | Step 4 |
| ÜNB | ÜNB | [Activation of a MaBiS metering point for the supplier aggregated time series from the ÜNB to LF](/en/prozessdoku/202604/UENB/MaBiS-aktivierung-eines-mabis-zaehlpunkts-fuer-die-lieferantensummenzeitreihe-vom-uenb-an-lf) | MaBiS | Electricity | Step 1 |
| ÜNB | ÜNB | [Activation of a MaBiS metering point for the daily balancing area aggregate time series from the ÜNB to NB](/en/prozessdoku/202604/UENB/MaBiS-aktivierung-eines-mabis-zaehlpunkts-fuer-die-taegliche-bilanzierungsgebietssummenzeitreihe-vom-uenb-an-nb) | MaBiS | Electricity | Step 1 |
| ÜNB | ÜNB | [Activation of a MaBiS metering point for the daily balancing group aggregated time series from the ÜNB to BKV](/en/prozessdoku/202604/UENB/MaBiS-aktivierung-eines-mabis-zaehlpunkts-fuer-die-taegliche-bilanzkreissummenzeitreihe-vom-uenb-an-bkv) | MaBiS | Electricity | Step 1 |
| BIKO | BIKO | [Activation of a MaBiS metering point for the delta time series carry-over from the ÜNB to BIKO and NB](/en/prozessdoku/202604/BIKO/MaBiS-aktivierung-eines-mabis-zaehlpunkts-fuer-den-deltazeitreihenuebertrag-vom-uenb-an-biko-und-nb) | MaBiS | Electricity | Step 1 |
| BIKO | BIKO | [Activation of a MaBiS metering point for the delta time series carry-over from the ÜNB to BIKO and NB](/en/prozessdoku/202604/BIKO/MaBiS-aktivierung-eines-mabis-zaehlpunkts-fuer-den-deltazeitreihenuebertrag-vom-uenb-an-biko-und-nb) | MaBiS | Electricity | Step 4 |
| BIKO | BIKO | [Activation of a MaBiS metering point for the settlement aggregated time series from the BIKO to BKV](/en/prozessdoku/202604/BIKO/MaBiS-aktivierung-eines-mabis-zaehlpunkts-fuer-die-abrechnungssummenzeitreihe-vom-biko-an-bkv) | MaBiS | Electricity | Step 1 |
| BIKO | BIKO | [Activation of a MaBiS metering point for the settlement aggregated time series from the BIKO to NB](/en/prozessdoku/202604/BIKO/MaBiS-aktivierung-eines-mabis-zaehlpunkts-fuer-die-abrechnungssummenzeitreihe-vom-biko-an-nb) | MaBiS | Electricity | Step 1 |
| BIKO | BIKO | [Activation of a MaBiS metering point for the settlement aggregated time series from the BIKO to ÜNB](/en/prozessdoku/202604/BIKO/MaBiS-aktivierung-eines-mabis-zaehlpunkts-fuer-die-abrechnungssummenzeitreihe-vom-biko-an-uenb) | MaBiS | Electricity | Step 1 |
| BIKO | BIKO | [Activation of a MaBiS metering point for the balancing area aggregate time series from the ÜNB to BIKO and NB](/en/prozessdoku/202604/BIKO/MaBiS-aktivierung-eines-mabis-zaehlpunkts-fuer-die-bilanzierungsgebietssummenzeitreihe-vom-uenb-an-biko-und-nb) | MaBiS | Electricity | Step 1 |
| BIKO | BIKO | [Activation of a MaBiS metering point for the balancing area aggregate time series from the ÜNB to BIKO and NB](/en/prozessdoku/202604/BIKO/MaBiS-aktivierung-eines-mabis-zaehlpunkts-fuer-die-bilanzierungsgebietssummenzeitreihe-vom-uenb-an-biko-und-nb) | MaBiS | Electricity | Step 4 |
| BIKO | BIKO | [Activation of a MaBiS metering point for the balancing group aggregated time series from the NB to BIKO and BKV](/en/prozessdoku/202604/BIKO/MaBiS-aktivierung-eines-mabis-zaehlpunkts-fuer-die-bilanzkreissummenzeitreihe-vom-nb-an-biko-und-bkv) | MaBiS | Electricity | Step 1 |
| BIKO | BIKO | [Activation of a MaBiS metering point for the balancing group aggregated time series from the NB to BIKO and BKV](/en/prozessdoku/202604/BIKO/MaBiS-aktivierung-eines-mabis-zaehlpunkts-fuer-die-bilanzkreissummenzeitreihe-vom-nb-an-biko-und-bkv) | MaBiS | Electricity | Step 4 |
| BIKO | BIKO | [Activation of a MaBiS metering point for the balancing group aggregated time series from the ÜNB to BIKO and BKV](/en/prozessdoku/202604/BIKO/MaBiS-aktivierung-eines-mabis-zaehlpunkts-fuer-die-bilanzkreissummenzeitreihe-vom-uenb-an-biko-und-bkv) | MaBiS | Electricity | Step 1 |
| BIKO | BIKO | [Activation of a MaBiS metering point for the balancing group aggregated time series from the ÜNB to BIKO and BKV](/en/prozessdoku/202604/BIKO/MaBiS-aktivierung-eines-mabis-zaehlpunkts-fuer-die-bilanzkreissummenzeitreihe-vom-uenb-an-biko-und-bkv) | MaBiS | Electricity | Step 4 |
| BIKO | BIKO | [Activation of a MaBiS metering point for the grid time series](/en/prozessdoku/202604/BIKO/MaBiS-aktivierung-eines-mabis-zaehlpunkts-fuer-die-netzzeitreihe) | MaBiS | Electricity | Step 1 |
| BIKO | BIKO | [Activation of a MaBiS metering point for the grid time series](/en/prozessdoku/202604/BIKO/MaBiS-aktivierung-eines-mabis-zaehlpunkts-fuer-die-netzzeitreihe) | MaBiS | Electricity | Step 4 |
| BKV | BKV | [Activation of a MaBiS metering point for the settlement aggregated time series from the BIKO to BKV](/en/prozessdoku/202604/BKV/MaBiS-aktivierung-eines-mabis-zaehlpunkts-fuer-die-abrechnungssummenzeitreihe-vom-biko-an-bkv) | MaBiS | Electricity | Step 1 |
| BKV | BKV | [Activation of a MaBiS metering point for the balancing group aggregated time series from the NB to BIKO and BKV](/en/prozessdoku/202604/BKV/MaBiS-aktivierung-eines-mabis-zaehlpunkts-fuer-die-bilanzkreissummenzeitreihe-vom-nb-an-biko-und-bkv) | MaBiS | Electricity | Step 1 |
| BKV | BKV | [Activation of a MaBiS metering point for the balancing group aggregated time series from the NB to BIKO and BKV](/en/prozessdoku/202604/BKV/MaBiS-aktivierung-eines-mabis-zaehlpunkts-fuer-die-bilanzkreissummenzeitreihe-vom-nb-an-biko-und-bkv) | MaBiS | Electricity | Step 4 |
| BKV | BKV | [Activation of a MaBiS metering point for the balancing group aggregated time series from the ÜNB to BIKO and BKV](/en/prozessdoku/202604/BKV/MaBiS-aktivierung-eines-mabis-zaehlpunkts-fuer-die-bilanzkreissummenzeitreihe-vom-uenb-an-biko-und-bkv) | MaBiS | Electricity | Step 1 |
| BKV | BKV | [Activation of a MaBiS metering point for the balancing group aggregated time series from the ÜNB to BIKO and BKV](/en/prozessdoku/202604/BKV/MaBiS-aktivierung-eines-mabis-zaehlpunkts-fuer-die-bilanzkreissummenzeitreihe-vom-uenb-an-biko-und-bkv) | MaBiS | Electricity | Step 4 |
| BKV | BKV | [Activation of a MaBiS metering point for the daily balancing group aggregated time series from the ÜNB to BKV](/en/prozessdoku/202604/BKV/MaBiS-aktivierung-eines-mabis-zaehlpunkts-fuer-die-taegliche-bilanzkreissummenzeitreihe-vom-uenb-an-bkv) | MaBiS | Electricity | Step 1 |

</div>

## Business classification

<div className="maco-tabellenrahmen">

| Attribute | Value |
|---|---|
| Use case (AHB) | Activation of ZP |
| AHB | UTILMD AHB electricity |
| Transmission channel | AS4 |

</div>

:::caution{title="This check identifier is used in 20 contexts"}

Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.

:::

<div className="maco-tabellenrahmen">

| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| MaBiS | Activation of a MaBiS metering point for the grid time series | NB (responsible NB) → NB (neighbouring NB) | Activation of a MaBiS-ZP for the NZR |
| MaBiS | Activation of a MaBiS metering point for the grid time series | NB (responsible NB) → BIKO | Activation of a MaBiS-ZP for the NZR |
| MaBiS | Activation of a MaBiS metering point for the supplier aggregated time series from the NB to LF | NB → LF | Activation of a MaBiS-ZP for the LF-SZR (category A) |
| MaBiS | Activation of a MaBiS metering point for the supplier aggregated time series from the ÜNB to LF | ÜNB → LF | Activation of a MaBiS-ZP for the LF-SZR (category B) |
| MaBiS | Activation of a MaBiS metering point for the balancing area aggregate time series from the ÜNB to BIKO and NB | ÜNB → BIKO | Activation of a MaBiS-ZP for the BG-SZR (category B) |
| MaBiS | Activation of a MaBiS metering point for the balancing area aggregate time series from the ÜNB to BIKO and NB | BIKO → NB | Forwarding of the activated MaBiS-ZP for the BG-SZR (category B) |
| MaBiS | Activation of a MaBiS metering point for the balancing group aggregated time series from the NB to BIKO and BKV | NB → BIKO | Activation of a MaBiS-ZP for the BK-SZR (category A) |
| MaBiS | Activation of a MaBiS metering point for the balancing group aggregated time series from the NB to BIKO and BKV | BIKO → BKV | Forwarding of the activated MaBiS-ZP for the BK-SZR (category A) |
| MaBiS | Activation of a MaBiS metering point for the balancing group aggregated time series from the ÜNB to BIKO and BKV | ÜNB → BIKO | Activation of a MaBiS-ZP for the BK-SZR (category B) |
| MaBiS | Activation of a MaBiS metering point for the balancing group aggregated time series from the ÜNB to BIKO and BKV | BIKO → BKV | Forwarding of the activated MaBiS-ZP for BK-SZR (category B) |
| MaBiS | UF MaBiS_005 activation of a MaBiS metering point for the delta time series carry-over from the ÜNB to BIKO and NB | ÜNB → BIKO | Activation of a MaBiS-ZP for the DZÜ |
| MaBiS | UF MaBiS_005 activation of a MaBiS metering point for the delta time series carry-over from the ÜNB to BIKO and NB | BIKO → NB | Forwarding of the activated MaBiS-ZP for the DZÜ |
| MaBiS | Activation of a MaBiS metering point for the settlement aggregated time series from the BIKO to NB | BIKO → NB | Activation of a MaBiS-ZP for the NB-DZR |
| MaBiS | Activation of a MaBiS metering point for the settlement aggregated time series from the BIKO to BKV | BIKO → BKV | Activation of a MaBiS-ZP for the settlement aggregated time series |
| MaBiS | Activation of a MaBiS metering point for the settlement aggregated time series from the BIKO to ÜNB | BIKO → ÜNB | Activation of a MaBiS-ZP for the ÜNB-DZR |
| MaBiS | Activation of a MaBiS metering point for the daily balancing area aggregate time series from the ÜNB to NB | ÜNB → NB | Activation of a MaBiS-ZP for the BG-SZR (category C) |
| MaBiS | Activation of a MaBiS metering point for the daily balancing group aggregated time series from the ÜNB to BKV | ÜNB → BKV | Activation of a MaBiS-ZP for the BK-SZR (category C) |
| AWH Model 2 charg.-session-level bal. energy assign. option | Activation of a MaBiS metering point for the daily balancing group aggregated time series eMob from the NB (LPB) to ÜNB | NB (LPB) → ÜNB | Activation of a MaBiS-ZP for the daily  BK-SZR eMob |
| MaBiS | Activation of a MaBiS metering point for the delta time series carry-over from the ÜNB to BIKO and NB | ÜNB → BIKO | Activation of a MaBiS-ZP for the DZÜ |
| MaBiS | Activation of a MaBiS metering point for the delta time series carry-over from the ÜNB to BIKO and NB | BIKO → NB | Forwarding of the activated MaBiS-ZP for the DZÜ |

</div>

:::caution{title="Further relationships from format version 202610"}

Version 202610 also carries this check identifier in contexts that the table of version 202604 does not know; they are included in the list above. Everything else on this page — use case, rulebook and communication direction — comes from the page's own version. Before adopting it into an implementation specification, check whether what is stated applies to 202604.

:::

<Hinweisbereich>

The status column carries two vocabularies because the manual answers two questions: on a **group row**, *Muss*, *Soll* or *Kann* states whether the EDIFACT segment must be present; on a **field row**, *X* states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.

For this check identifier, the application handbook lists **109 rows**. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.

The **Condition** column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.

</Hinweisbereich>