# Check identifier 55204 — Response to ZP activation

<span hidden data-pagefind-meta={"title:Check identifier 55204 — Response to ZP activation · UTILMD · Format version 202604"} />

Check identifier **55204** · EDIFACT message type **UTILMD** · format version **202604**

:::info{title="This page is derived from the application handbook"}

The MACO APP does not carry this check identifier. The complete Prüfi pages of this level are produced from the specifications of the application — one class in the templater per check identifier — and that is where the **assignment to the business objects (BO4E)** comes from: which object carries which field of the message.

The catalogue of the application handbook is the larger set. This page therefore shows what the handbook itself provides — use case, process context and the AHB field list with its conditions. A data structure according to BO4E is not shown, and not because there is none, but because the application does not form one for this check identifier.

All check identifiers in this situation — and the corresponding figures — are listed by [the overview of this version](/en/schnittstellen/202604/pruefi/nicht-gefuehrt).

:::

## Application handbook (AHB)

<Handbuchsatz>

<div className="maco-tabellenrahmen" data-maco="ahb-tabelle">

| Structure (EDIFACT) | Description | Format | <span className="hbs-p" title="Antwort auf Aktivierung ZP">55204</span> | Condition |
|---|---|---|---|---|
| <span className="hbs-g hbs-e0">**UNH**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`0062`</span><span className="hbs-nr">00010</span> | Message reference number | — | X | — |
| <span className="hbs-f hbs-e1">`0065 UTILMD`</span><span className="hbs-nr">00020</span> | Grid connection master data | — | X | — |
| <span className="hbs-f hbs-e1">`0052 D`</span><span className="hbs-nr">00030</span> | Draft version | — | X | — |
| <span className="hbs-f hbs-e1">`0054 11A`</span><span className="hbs-nr">00040</span> | Edition 2011 - A | — | X | — |
| <span className="hbs-f hbs-e1">`0051 UN`</span><span className="hbs-nr">00050</span> | UN/CEFACT | — | X | — |
| <span className="hbs-f hbs-e1">`0057 S2.1`</span><span className="hbs-nr">00060</span> | Version number of the underlying BDEW message description | — | X | — |
| <span className="hbs-g hbs-e0">**BGM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1001 Z07`</span><span className="hbs-nr">00070</span> | Activation/ deactivation of MaBiS-ZP | — | X | — |
| <span className="hbs-f hbs-e1">`1004`</span><span className="hbs-nr">00080</span> | Document number | — | X | — |
| <span className="hbs-g hbs-e0">**DTM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`2005 137`</span><span className="hbs-nr">00090</span> | Document-/message date/time | — | X | — |
| <span className="hbs-f hbs-e1">`2380`</span><span className="hbs-nr">00100</span> | Date or time or time span, value | — | X | <span className="hbs-marke">[931]</span> <span className="hbs-marke">[494]</span> |
| <span className="hbs-f hbs-e1">`2379 303`</span><span className="hbs-nr">00110</span> | CCYYMMDDHHMMZZZ | — | X | — |
| <span className="hbs-g hbs-e0">**SG2.NAD**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3035 MS`</span><span className="hbs-nr">00120</span> | Document-/message sender or sender | — | X | — |
| <span className="hbs-f hbs-e1">`3039`</span><span className="hbs-nr">00130</span> | MP-ID | — | X | — |
| <span className="hbs-f hbs-e1">`3055 9`</span><span className="hbs-nr">00140</span> | GS1 | — | X | — |
| <span className="hbs-f hbs-e1">`3055 293`</span><span className="hbs-nr">00150</span> | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| <span className="hbs-g hbs-e0">**SG3.CTA**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3139 IC`</span><span className="hbs-nr">00160</span> | Information contact | — | X | — |
| <span className="hbs-f hbs-e1">`3412`</span><span className="hbs-nr">00170</span> | Name of the contact person | — | X | — |
| <span className="hbs-g hbs-e0">**SG3.COM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3148`</span><span className="hbs-nr">00180</span> | Number / address | — | X | ((<span className="hbs-marke">[939]</span> <span className="hbs-marke">[321]</span>) ∨ (<span className="hbs-marke">[940]</span> <span className="hbs-marke">[322]</span>)) ∧ <span className="hbs-marke">[514]</span> |
| <span className="hbs-f hbs-e1">`3155 EM`</span><span className="hbs-nr">00190</span> | Electronic mail | — | X | <span className="hbs-marke">[1P0..1]</span> |
| <span className="hbs-f hbs-e1">`3155 FX`</span><span className="hbs-nr">00200</span> | Fax number | — | X | <span className="hbs-marke">[1P0..1]</span> |
| <span className="hbs-f hbs-e1">`3155 TE`</span><span className="hbs-nr">00210</span> | Telephone | — | X | <span className="hbs-marke">[1P0..1]</span> |
| <span className="hbs-f hbs-e1">`3155 AJ`</span><span className="hbs-nr">00220</span> | further telephone | — | X | <span className="hbs-marke">[1P0..1]</span> |
| <span className="hbs-f hbs-e1">`3155 AL`</span><span className="hbs-nr">00230</span> | Mobile phone | — | X | <span className="hbs-marke">[1P0..1]</span> |
| <span className="hbs-g hbs-e0">**SG2.NAD**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3035 MR`</span><span className="hbs-nr">00240</span> | Message recipient | — | X | — |
| <span className="hbs-f hbs-e1">`3039`</span><span className="hbs-nr">00250</span> | MP-ID | — | X | <span className="hbs-marke">[280]</span> |
| <span className="hbs-f hbs-e1">`3055 9`</span><span className="hbs-nr">00260</span> | GS1 | — | X | — |
| <span className="hbs-f hbs-e1">`3055 293`</span><span className="hbs-nr">00270</span> | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| <span className="hbs-g hbs-e0">**SG4.IDE**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7495 24`</span><span className="hbs-nr">00280</span> | Transaction | — | X | — |
| <span className="hbs-f hbs-e1">`7402`</span><span className="hbs-nr">00290</span> | Transaction number | — | X | — |
| <span className="hbs-g hbs-e0">**SG4.DTM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`2005 158`</span><span className="hbs-nr">00300</span> | Start of balancing | — | X | — |
| <span className="hbs-f hbs-e1">`2380`</span><span className="hbs-nr">00310</span> | Date or time or time span, value | — | X | <span className="hbs-marke">[UB1]</span> |
| <span className="hbs-f hbs-e1">`2379 303`</span><span className="hbs-nr">00320</span> | CCYYMMDDHHMMZZZ | — | X | — |
| <span className="hbs-g hbs-e0">**SG4.STS**</span> | — | — | Must | <span className="hbs-marke">[249]</span> |
| <span className="hbs-f hbs-e1">`9015 E01`</span><span className="hbs-nr">00330</span> | Status of the response | — | X | — |
| <span className="hbs-f hbs-e1">`9013`</span><span className="hbs-nr">00340</span> | Code of the check step | — | X | — |
| <span className="hbs-f hbs-e1">`1131 E_0071`</span><span className="hbs-nr">00350</span> | EBD no. E_0071 | — | X | — |
| <span className="hbs-g hbs-e0">**SG5.LOC**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3227 Z15`</span><span className="hbs-nr">00360</span> | MaBiS metering point | — | X | — |
| <span className="hbs-f hbs-e1">`3225`</span><span className="hbs-nr">00370</span> | Identifier | — | X | <span className="hbs-marke">[951]</span> |
| <span className="hbs-g hbs-e0">**SG6.RFF**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1153 Z13`</span><span className="hbs-nr">00380</span> | Check identifier | — | X | — |
| <span className="hbs-f hbs-e1">`1154 55204`</span><span className="hbs-nr">00390</span> | Redispatch / Response to activation ZP | — | X | — |
| <span className="hbs-g hbs-e0">**SG6.RFF**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1153 TN`</span><span className="hbs-nr">00400</span> | Transaction reference number | — | X | — |
| <span className="hbs-f hbs-e1">`1154`</span><span className="hbs-nr">00410</span> | Transaction number | — | X | — |
| <span className="hbs-g hbs-e0">**UNT**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`0074`</span><span className="hbs-nr">00420</span> | Number of segments in a message | — | X | — |
| <span className="hbs-f hbs-e1">`0062`</span><span className="hbs-nr">00430</span> | Message reference number | — | X | — |

</div>

</Handbuchsatz>

### Conditions of this table

The free text of the 12 conditions referenced by the rows above. All conditions of the message type are listed in the [condition index UTILMDS](/en/referenz/202604/ahb-bedingungen/UTILMDS).

<div className="maco-tabellenrahmen">

| Marker | Condition |
|---|---|
| **[249]** | Within one SG4 IDE, all DE1131 of the SG4 STS+E01 (status of the response) must contain the identical value |
| **[280]** | Only MP-ID from the electricity division |
| **[321]** | If code EM is present in DE3155 in the same COM |
| **[322]** | If code TE / FX / AJ / AL is present in DE3155 in the same COM |
| **[494]** | The date stated here must be the point in time at which the document was created, or a point in time before that |
| **[514]** | Note: Only one piece of information may be transmitted in DE3148 |
| **[931]** | Format: ZZZ = +00 |
| **[939]** | Format: the character string must contain the characters @ and . |
| **[940]** | Format: the character string must begin with the character + and may only be followed by digits |
| **[951]** | Format: Metering point identifier |
| **[1P0..1]** | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
| **[UB1]** | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |

</div>

## Belongs to these role views

The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are **NB**, **BIKO** and **BKV**.

<div className="maco-tabellenrahmen">

| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| NB | ANB | [Activation of a MaBiS-ZP for the monthly curtailed energy transfer time series (AAÜZ) between NB and BKV (of the LF)](/en/prozessdoku/202604/NB/MaBiS-aktivierung-eines-mabis-zp-fuer-die-monatliche-ausfallarbeitsueberfuehrungszeitreihe-aauez-zwischen-nb-und-bkv-des-lf) | MaBiS | Electricity | Step 2 |
| BIKO | BIKO | [Activation of a MaBiS-ZP for the monthly curtailed energy transfer time series (AAÜZ) between NB and BKV (of the LF)](/en/prozessdoku/202604/BIKO/MaBiS-aktivierung-eines-mabis-zp-fuer-die-monatliche-ausfallarbeitsueberfuehrungszeitreihe-aauez-zwischen-nb-und-bkv-des-lf) | MaBiS | Electricity | Step 2 |
| BKV | BKV-LF | [Activation of a MaBiS-ZP for the monthly curtailed energy transfer time series (AAÜZ) between NB and BKV (of the LF)](/en/prozessdoku/202604/BKV/MaBiS-aktivierung-eines-mabis-zp-fuer-die-monatliche-ausfallarbeitsueberfuehrungszeitreihe-aauez-zwischen-nb-und-bkv-des-lf) | MaBiS | Electricity | Step 2 |

</div>

## Business classification

<div className="maco-tabellenrahmen">

| Attribute | Value |
|---|---|
| Use case (AHB) | Response to activation of ZP |
| AHB | UTILMD AHB electricity |
| Decision tree | [E_0071](/referenz/202604/ebd/E_0071) |
| Transmission channel | AS4 |

</div>

<div className="maco-tabellenrahmen">

| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| MaBiS | Activation of a MaBiS-ZP for the monthly curtailed energy transfer time series (AAÜZ) between NB and BKV (of the LF) | BIKO → NB (ANB) | Response |

</div>

:::caution{title="One entry from format version 202610"}

The check identifiers table of format version 202604 does not carry this entry: **decision tree**. It comes from version 202610. Everything else on this page — use case, rulebook and communication direction — comes from its own version. Before adopting this into an implementation specification, check whether what is stated applies to 202604.

:::

<Hinweisbereich>

The status column carries two vocabularies because the manual answers two questions: on a **group row**, *Muss*, *Soll* or *Kann* states whether the EDIFACT segment must be present; on a **field row**, *X* states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.

For this check identifier, the application handbook lists **57 rows**. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.

The **Condition** column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.

</Hinweisbereich>