# Check identifier 21000 — Status message

<span hidden data-pagefind-meta={"title:Check identifier 21000 — Status message · IFTSTA · Format version 202610"} />

Check identifier **21000** · EDIFACT message type **IFTSTA** · Format version **202610**

:::info{title="This page is derived from the application handbook"}

The MACO APP does not carry this check identifier. The complete Prüfi pages of this level are produced from the specifications of the application — one class in the templater per check identifier — and that is where the **assignment to the business objects (BO4E)** comes from: which object carries which field of the message.

The catalogue of the application handbook is the larger set. This page therefore shows what the handbook itself provides — use case, process context and the AHB field list with its conditions. A data structure according to BO4E is not shown, and not because there is none, but because the application does not form one for this check identifier.

All check identifiers in this situation — and the corresponding figures — are listed by [the overview of this version](/en/schnittstellen/202610/pruefi/nicht-gefuehrt).

:::

## Application handbook (AHB)

<Handbuchsatz>

<div className="maco-tabellenrahmen" data-maco="ahb-tabelle">

| Structure (EDIFACT) | Description | Format | <span className="hbs-p" title="Statusmeldung">21000</span> | Condition |
|---|---|---|---|---|
| <span className="hbs-g hbs-e0">**UNH**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`0062`</span><span className="hbs-nr">00010</span> | Message reference number | — | X | — |
| <span className="hbs-f hbs-e1">`0065 IFTSTA`</span><span className="hbs-nr">00020</span> | Multimodal status report | — | X | — |
| <span className="hbs-f hbs-e1">`0052 D`</span><span className="hbs-nr">00030</span> | Draft version | — | X | — |
| <span className="hbs-f hbs-e1">`0054 18A`</span><span className="hbs-nr">00040</span> | Edition 2018 - A | — | X | — |
| <span className="hbs-f hbs-e1">`0051 UN`</span><span className="hbs-nr">00050</span> | UN/CEFACT | — | X | — |
| <span className="hbs-f hbs-e1">`0057 2.1`</span><span className="hbs-nr">00060</span> | Version number of the underlying BDEW message description | — | X | — |
| <span className="hbs-g hbs-e0">**BGM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1001 Z03`</span><span className="hbs-nr">00070</span> | MaBiS message(s) | — | X | — |
| <span className="hbs-f hbs-e1">`1004`</span><span className="hbs-nr">00080</span> | Document number | — | X | — |
| <span className="hbs-g hbs-e0">**DTM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`2005 137`</span><span className="hbs-nr">00090</span> | Document-/message date/time | — | X | — |
| <span className="hbs-f hbs-e1">`2380`</span><span className="hbs-nr">00100</span> | Date or time or time span, value | — | X | <span className="hbs-marke">[931]</span> <span className="hbs-marke">[494]</span> |
| <span className="hbs-f hbs-e1">`2379 303`</span><span className="hbs-nr">00110</span> | CCYYMMDDHHMMZZZ | — | X | — |
| <span className="hbs-g hbs-e0">**SG1.NAD**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3035 MR`</span><span className="hbs-nr">00120</span> | Message recipient | — | X | — |
| <span className="hbs-f hbs-e1">`3039`</span><span className="hbs-nr">00130</span> | MP-ID | — | X | <span className="hbs-marke">[27]</span> |
| <span className="hbs-f hbs-e1">`3055 9`</span><span className="hbs-nr">00140</span> | GS1 | — | X | — |
| <span className="hbs-f hbs-e1">`3055 293`</span><span className="hbs-nr">00150</span> | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| <span className="hbs-g hbs-e0">**SG1.NAD**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3035 MS`</span><span className="hbs-nr">00160</span> | Document-/message sender or sender | — | X | — |
| <span className="hbs-f hbs-e1">`3039`</span><span className="hbs-nr">00170</span> | MP-ID | — | X | <span className="hbs-marke">[27]</span> |
| <span className="hbs-f hbs-e1">`3055 9`</span><span className="hbs-nr">00180</span> | GS1 | — | X | — |
| <span className="hbs-f hbs-e1">`3055 293`</span><span className="hbs-nr">00190</span> | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| <span className="hbs-g hbs-e0">**SG4.EQD**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`8053 Z01`</span><span className="hbs-nr">00200</span> | Sequential number | — | X | — |
| <span className="hbs-f hbs-e1">`8260`</span><span className="hbs-nr">00210</span> | Transaction number | — | X | <span className="hbs-marke">[911]</span> |
| <span className="hbs-g hbs-e0">**SG4.RFF**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1153 Z13`</span><span className="hbs-nr">00220</span> | Check identifier | — | X | — |
| <span className="hbs-f hbs-e1">`1154 21000`</span><span className="hbs-nr">00230</span> | MaBiS / status message from the LF to the NB/ÜNB | — | X | — |
| <span className="hbs-g hbs-e0">**SG4.RFF**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1153 AUU`</span><span className="hbs-nr">00240</span> | Reference to a time series | — | X | — |
| <span className="hbs-f hbs-e1">`1154`</span><span className="hbs-nr">00250</span> | Version of the aggregated time series | — | X | — |
| <span className="hbs-g hbs-e0">**SG6.LOC**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3227 172`</span><span className="hbs-nr">00260</span> | Reporting point | — | X | — |
| <span className="hbs-f hbs-e1">`3225`</span><span className="hbs-nr">00270</span> | Identifier | — | X | <span className="hbs-marke">[951]</span> <span className="hbs-marke">[504]</span> |
| <span className="hbs-g hbs-e0">**SG6.DTM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`2005 492`</span><span className="hbs-nr">00280</span> | Balancing date, -time, -period | — | X | — |
| <span className="hbs-f hbs-e1">`2380`</span><span className="hbs-nr">00290</span> | Date or time or time span, value | — | X | — |
| <span className="hbs-f hbs-e1">`2379 610`</span><span className="hbs-nr">00300</span> | CCYYMM | — | X | — |
| <span className="hbs-g hbs-e0">**SG6.DTM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`2005 334`</span><span className="hbs-nr">00310</span> | Status change, date/time | — | X | — |
| <span className="hbs-f hbs-e1">`2380`</span><span className="hbs-nr">00320</span> | Date or time or time span, value | — | X | <span className="hbs-marke">[931]</span> <span className="hbs-marke">[495]</span> |
| <span className="hbs-f hbs-e1">`2379 304`</span><span className="hbs-nr">00330</span> | CCYYMMDDHHMMSSZZZ | — | X | — |
| <span className="hbs-g hbs-e0">**SG7.STS**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`9015 Z01`</span><span className="hbs-nr">00340</span> | Check status of response to aggregated time series | — | X | — |
| <span className="hbs-f hbs-e1">`4405 Z07`</span><span className="hbs-nr">00350</span> | Time series accepted | — | X | — |
| <span className="hbs-f hbs-e1">`4405 Z08`</span><span className="hbs-nr">00360</span> | Time series not accepted | — | X | — |
| <span className="hbs-f hbs-e1">`9013`</span><span className="hbs-nr">00370</span> | Code of the check step | — | X | <span className="hbs-marke">[43]</span> ∨ <span className="hbs-marke">[44]</span> |
| <span className="hbs-f hbs-e1">`1131 E_0007`</span><span className="hbs-nr">00380</span> | EBD no. E_0007 | — | X | — |
| <span className="hbs-f hbs-e1">`1131 E_0041`</span><span className="hbs-nr">00390</span> | EBD no. E_0041 | — | X | — |
| <span className="hbs-f hbs-e1">`1131 E_0093`</span><span className="hbs-nr">00400</span> | EBD no. E_0093 | — | X | — |
| <span className="hbs-g hbs-e0">**SG7.STS**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`9015 Z02`</span><span className="hbs-nr">00410</span> | Refusal of the aggregated time series | — | X | — |
| <span className="hbs-f hbs-e1">`9013`</span><span className="hbs-nr">00420</span> | Code of the check step | — | X | <span className="hbs-marke">[51]</span> |
| <span className="hbs-f hbs-e1">`1131 E_0007`</span><span className="hbs-nr">00430</span> | EBD no. E_0007 | — | X | — |
| <span className="hbs-f hbs-e1">`1131 E_0041`</span><span className="hbs-nr">00440</span> | EBD no. E_0041 | — | X | — |
| <span className="hbs-f hbs-e1">`1131 E_0093`</span><span className="hbs-nr">00450</span> | EBD no. E_0093 | — | X | — |
| <span className="hbs-g hbs-e0">**UNT**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`0074`</span><span className="hbs-nr">00460</span> | Number of segments in a message | — | X | — |
| <span className="hbs-f hbs-e1">`0062`</span><span className="hbs-nr">00470</span> | Message reference number | — | X | — |

</div>

</Handbuchsatz>

### Conditions of this table

The free text of the 10 conditions referenced by the rows above. All conditions of the message type are listed in the [condition index IFTSTA](/en/referenz/202610/ahb-bedingungen/IFTSTA).

<div className="maco-tabellenrahmen">

| Marker | Condition |
|---|---|
| **[27]** | Only MP-ID from the electricity division |
| **[43]** | If STS+Z01+Z07 present, only codes from the EBD cluster "consent" are possible. |
| **[44]** | If STS+Z01+Z08 present, only codes from the EBD cluster "rejection" are possible. |
| **[51]** | Only codes from the EBD cluster "refusal" are possible. |
| **[494]** | The date stated here must be the point in time at which the document was created, or a point in time before that |
| **[495]** | The point in time must be ≤ the value in DE2380 of DTM+137 |
| **[504]** | Note: Use of the ID of the MaBiS-ZP |
| **[911]** | Format: Possible values: 1 to n, starting at 1 for each message and ascending consecutively |
| **[931]** | Format: ZZZ = +00 |
| **[951]** | Format: Metering point identifier |

</div>

## Belongs to these role views

The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are **LF**, **NB** and **ÜNB**.

<div className="maco-tabellenrahmen">

| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | [Transmission of the supplier curtailed energy aggregated time series](/en/prozessdoku/202610/LF/MaBiS-uebermittlung-der-lieferantenausfallarbeitssummenzeitreihe) | MaBiS | Electricity | Step 2 |
| LF | LF | [Transmission of the supplier aggregated time series from the NB to LF](/en/prozessdoku/202610/LF/MaBiS-uebermittlung-der-lieferantensummenzeitreihe-vom-nb-an-lf) | MaBiS | Electricity | Step 2 |
| LF | LF | [Transmission of the supplier aggregated time series from the ÜNB to LF](/en/prozessdoku/202610/LF/MaBiS-uebermittlung-der-lieferantensummenzeitreihe-vom-uenb-an-lf) | MaBiS | Electricity | Step 2 |
| NB | ANB | [Transmission of the supplier curtailed energy aggregated time series](/en/prozessdoku/202610/NB/MaBiS-uebermittlung-der-lieferantenausfallarbeitssummenzeitreihe) | MaBiS | Electricity | Step 2 |
| NB | NB | [Transmission of the supplier aggregated time series from the NB to LF](/en/prozessdoku/202610/NB/MaBiS-uebermittlung-der-lieferantensummenzeitreihe-vom-nb-an-lf) | MaBiS | Electricity | Step 2 |
| ÜNB | ÜNB | [Transmission of the supplier aggregated time series from the ÜNB to LF](/en/prozessdoku/202610/UENB/MaBiS-uebermittlung-der-lieferantensummenzeitreihe-vom-uenb-an-lf) | MaBiS | Electricity | Step 2 |

</div>

## Business classification

<div className="maco-tabellenrahmen">

| Attribute | Value |
|---|---|
| Use case (AHB) | Status message |
| AHB | IFTSTA AHB |
| Decision tree | [E_0007](/referenz/202610/ebd/E_0007) · [E_0041](/referenz/202610/ebd/E_0041) · [E_0093](/referenz/202610/ebd/E_0093) |
| Transmission channel | AS4 |

</div>

:::caution{title="This check identifier is used in 3 contexts"}

Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.

:::

<div className="maco-tabellenrahmen">

| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| MaBiS | Transmission of the supplier aggregated time series from the NB to LF | LF → NB | Transmission of validation notification |
| MaBiS | Transmission of the supplier aggregated time series from the ÜNB to LF | LF → ÜNB | Transmission of validation notification |
| MaBiS | Transmission of the supplier curtailed energy aggregated time series | LF → NB (ANB) | Validation notification |

</div>

<Hinweisbereich>

The status column carries two vocabularies because the manual answers two questions: on a **group row**, *Muss*, *Soll* or *Kann* states whether the EDIFACT segment must be present; on a **field row**, *X* states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.

For this check identifier, the application handbook lists **61 rows**. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.

The **Condition** column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.

</Hinweisbereich>