# Check identifier 23011 — Information notification

<span hidden data-pagefind-meta={"title:Check identifier 23011 — Information notification · INSRPT · Format version 202610"} />

Check identifier **23011** · EDIFACT message type **INSRPT** · Format version **202610**

## Data structure

<Handbuchsatz>

<div className="maco-tabellenrahmen">

| Structure (BO4E) | Description | Format | <span className="hbs-p" title="Informationsmeldung">23011</span> | Condition |
|---|---|---|---|---|
| <span className="hbs-g hbs-e0">**stammdaten** <span className="hbs-pflicht">\*</span></span> | — | object | Must | — |
| <span className="hbs-g hbs-e1">**STATUSMITTEILUNG** <span className="hbs-liste">[ ]</span> <span className="hbs-pflicht">\*</span></span> | — | object[] | Must | — |
| <span className="hbs-g hbs-e2">**positionsdaten** <span className="hbs-liste">[ ]</span> <span className="hbs-pflicht">\*</span></span> | — | object[] | Must | — |
| <span className="hbs-f hbs-e3">[auftragsstatus](/en/bo4e/202610/com/StatusmitteilungPosition#auftragsstatus) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="23011" format="INSRPT" fv="202610" zeile={43} segment="SG3.DOC+23.SG7.LIN.STS+Z06" /><span className="hbs-nr">00010</span> | Order status | [Enum Auftragsstatus](/en/bo4e/202610/enum/Auftragsstatus) | X | — |
| <span className="hbs-w hbs-e4">`GESCHEITERT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e4">`ERFOLGREICH`</span> | — | — | X | — |
| <span className="hbs-w hbs-e4">`LIEFERUNG_GEPLANT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e4">`GEPLANT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e4">`ZUGESTIMMT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e4">`WIDERSPROCHEN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e4">`STOERUNGSFREI`</span> | — | — | X | — |
| <span className="hbs-w hbs-e4">`GESTOERT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e4">`FESTGESTELLTE_STOERUNG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e4">`VERMUTETE_STOERUNG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e4">`ABGELEHNT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e4">`BEENDET`</span> | — | — | X | — |
| <span className="hbs-w hbs-e4">`ANTWORT_DRITTER`</span> | — | — | X | — |
| <span className="hbs-w hbs-e4">`BESTAETIGT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e4">`UMGESETZT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e4">`ENFG_STROMSPEICHER_UND_VERLUSTENERGIE`</span> | — | — | X | — |
| <span className="hbs-w hbs-e4">`ENFG_ELEKTRISCH_ANGETRIEBENE_WAERMEPUMPEN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e4">`ENFG_UMLAGEERHEBUNG_BEI_ANLAGEN_ZUR_VERSTROMUNG_VON_KUPPELGASEN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e4">`ENFG_HERSTELLUNG_VON_GRUENEN_WASSERSTOFF`</span> | — | — | X | — |
| <span className="hbs-w hbs-e4">`ENFG_STROMKOSTENINTENSIVE_UNTERNEHMEN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e4">`ENFG_HERSTELLUNG_VON_WASSERSTOFF_IN_STROMKOSTENINTENSIVEN_UNTERNEHMEN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e4">`ENFG_SCHIENENBAHNEN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e4">`ENFG_ELEKTRISCHE_BETRIEBENE_BUSSEN_IM_LINIENVERKEHR`</span> | — | — | X | — |
| <span className="hbs-w hbs-e4">`ENFG_LANDSTROMANLAGEN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e4">`AENDERUNG_DER_DATEN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e4">`KEINE_AENDERUNG_DER_DATEN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e4">`ZEITREIHE_AKZEPTIERT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e4">`ZEITREIHE_NICHT_AKZEPTIERT`</span> | — | — | X | — |
| <span className="hbs-f hbs-e3">[enddatum](/en/bo4e/202610/com/StatusmitteilungPosition#enddatum) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="23011" format="INSRPT" fv="202610" zeile={38} segment="SG3.DOC+23.SG7.LIN.DTM+292" /><span className="hbs-nr">00020</span> | enddatum | string (date-time) | X | — |
| <span className="hbs-f hbs-e3">[lokationsId](/en/bo4e/202610/com/StatusmitteilungPosition#lokationsid) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="23011" format="INSRPT" fv="202610" zeile={51} segment="SG3.DOC+23.SG7.LIN.SG8.NAD+DP.LOC+172" /><span className="hbs-nr">00030</span> | lokationsId | string | X | — |
| <span className="hbs-f hbs-e3">[positionsnummer](/en/bo4e/202610/com/StatusmitteilungPosition#positionsnummer) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="23011" format="INSRPT" fv="202610" zeile={30} segment="SG3.DOC+23.SG7.LIN" /><span className="hbs-nr">00040</span> | positionsnummer | integer | Must | — |
| <span className="hbs-f hbs-e3">[referenzMelo](/en/bo4e/202610/com/StatusmitteilungPosition#referenzmelo)</span> <AhbTabelle pruefid="23011" format="INSRPT" fv="202610" zeile={53} segment="SG3.DOC+23.SG7.LIN.SG8.NAD+DP.RFF+Z21" /><span className="hbs-nr">00050</span> | referenzMelo | string | X | — |
| <span className="hbs-f hbs-e3">[verwendungAb](/en/bo4e/202610/com/StatusmitteilungPosition#verwendungab)</span> <AhbTabelle pruefid="23011" format="INSRPT" fv="202610" zeile={33} segment="SG3.DOC+23.SG7.LIN.DTM+163" /><span className="hbs-nr">00060</span> | verwendungAb | string (date-time) | X | — |
| <span className="hbs-g hbs-e3">**fehlerbeschreibung**</span> | — | object | May | — |
| <span className="hbs-f hbs-e4">[beschreibung1](/en/bo4e/202610/com/Fehlerbeschreibung#beschreibung1)</span> <AhbTabelle pruefid="23011" format="INSRPT" fv="202610" zeile={46} segment="SG3.DOC+23.SG7.LIN.FTX+AAO" /><span className="hbs-nr">00070</span> | Error description line 1 | string | X | — |
| <span className="hbs-f hbs-e4">[beschreibung2](/en/bo4e/202610/com/Fehlerbeschreibung#beschreibung2)</span> <AhbTabelle pruefid="23011" format="INSRPT" fv="202610" zeile={46} segment="SG3.DOC+23.SG7.LIN.FTX+AAO" /><span className="hbs-nr">00080</span> | Error description line 2 | string | X | — |
| <span className="hbs-f hbs-e4">[beschreibung3](/en/bo4e/202610/com/Fehlerbeschreibung#beschreibung3)</span> <AhbTabelle pruefid="23011" format="INSRPT" fv="202610" zeile={46} segment="SG3.DOC+23.SG7.LIN.FTX+AAO" /><span className="hbs-nr">00090</span> | Error description line 3 | string | X | — |
| <span className="hbs-f hbs-e4">[beschreibung4](/en/bo4e/202610/com/Fehlerbeschreibung#beschreibung4)</span> <AhbTabelle pruefid="23011" format="INSRPT" fv="202610" zeile={46} segment="SG3.DOC+23.SG7.LIN.FTX+AAO" /><span className="hbs-nr">00100</span> | Error description line 4 | string | X | — |
| <span className="hbs-f hbs-e4">[beschreibung5](/en/bo4e/202610/com/Fehlerbeschreibung#beschreibung5)</span> <AhbTabelle pruefid="23011" format="INSRPT" fv="202610" zeile={46} segment="SG3.DOC+23.SG7.LIN.FTX+AAO" /><span className="hbs-nr">00110</span> | Error description line 5 | string | X | — |
| <span className="hbs-g hbs-e0">**transaktionsdaten** <span className="hbs-pflicht">\*</span></span> | — | object | Must | — |
| <span className="hbs-f hbs-e1">[dokumentennummer](/en/bo4e/202610/cdoc/Transaktionsdaten#dokumentennummer) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="23011" format="INSRPT" fv="202610" zeile={8} segment="BGM+4" /><span className="hbs-nr">00120</span> | EDIFACT reference from the BGM segment / BGM | string | X | — |
| <span className="hbs-f hbs-e1">[nachrichtendatum](/en/bo4e/202610/cdoc/Transaktionsdaten#nachrichtendatum) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="23011" format="INSRPT" fv="202610" zeile={11} segment="DTM+137" /><span className="hbs-nr">00130</span> | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| <span className="hbs-f hbs-e1">[nachrichtenreferenznummer](/en/bo4e/202610/cdoc/Transaktionsdaten#nachrichtenreferenznummer) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="23011" format="INSRPT" fv="202610" zeile={0} segment="UNH" /><span className="hbs-nr">00140</span> | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| <span className="hbs-f hbs-e1">[pruefidentifikator](/en/bo4e/202610/cdoc/Transaktionsdaten#pruefidentifikator) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="23011" format="INSRPT" fv="202610" zeile={28} segment="SG3.DOC+23.SG4.RFF+Z13" /><span className="hbs-nr">00150</span> | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| <span className="hbs-f hbs-e1">[vorgangsnummer](/en/bo4e/202610/cdoc/Transaktionsdaten#vorgangsnummer) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="23011" format="INSRPT" fv="202610" zeile={25} segment="SG3.DOC+23" /><span className="hbs-nr">00160</span> | Number of the transaction / UTILMD UTILTS IDE+24 / INSRPT INVOIC DOC | string | X | — |
| <span className="hbs-g hbs-e1">**absender** <span className="hbs-pflicht">\*</span></span> | — | object | Must | — |
| <span className="hbs-f hbs-e2">[rollencodenummer](/en/bo4e/202610/bo/Marktteilnehmer#rollencodenummer) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="23011" format="INSRPT" fv="202610" zeile={20} segment="SG2.NAD+MS" /><span className="hbs-nr">00170</span> | Specifies the code value of the market role. | string | X | — |
| <span className="hbs-f hbs-e2">[rollencodetyp](/en/bo4e/202610/bo/Marktteilnehmer#rollencodetyp) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="23011" format="INSRPT" fv="202610" zeile={20} segment="SG2.NAD+MS" /><span className="hbs-nr">00180</span> | Indicates the type of the code. | [Enum Rollencodetyp](/en/bo4e/202610/enum/Rollencodetyp) | X | — |
| <span className="hbs-w hbs-e3">`BDEW`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`GS1`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`GLN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`DVGW`</span> | — | — | X | — |
| <span className="hbs-g hbs-e1">**empfaenger** <span className="hbs-pflicht">\*</span></span> | — | object | Must | — |
| <span className="hbs-f hbs-e2">[rollencodenummer](/en/bo4e/202610/bo/Marktteilnehmer#rollencodenummer) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="23011" format="INSRPT" fv="202610" zeile={15} segment="SG2.NAD+MR" /><span className="hbs-nr">00190</span> | Specifies the code value of the market role. | string | X | — |
| <span className="hbs-f hbs-e2">[rollencodetyp](/en/bo4e/202610/bo/Marktteilnehmer#rollencodetyp) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="23011" format="INSRPT" fv="202610" zeile={15} segment="SG2.NAD+MR" /><span className="hbs-nr">00200</span> | Indicates the type of the code. | [Enum Rollencodetyp](/en/bo4e/202610/enum/Rollencodetyp) | X | — |
| <span className="hbs-w hbs-e3">`BDEW`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`GS1`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`GLN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`DVGW`</span> | — | — | X | — |

</div>

</Handbuchsatz>

## Application handbook (AHB)

<Handbuchsatz>

<div className="maco-tabellenrahmen" data-maco="ahb-tabelle">

| Structure (EDIFACT) | Description | Format | <span className="hbs-p" title="Informationsmeldung">23011</span> | Condition |
|---|---|---|---|---|
| <span className="hbs-g hbs-e0">**UNH**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`0062`</span><span className="hbs-nr">00010</span> | Message reference number | — | X | — |
| <span className="hbs-f hbs-e1">`0065 INSRPT`</span><span className="hbs-nr">00020</span> | Check report | — | X | — |
| <span className="hbs-f hbs-e1">`0052 D`</span><span className="hbs-nr">00030</span> | Draft version | — | X | — |
| <span className="hbs-f hbs-e1">`0054 10A`</span><span className="hbs-nr">00040</span> | Edition 2010 - A | — | X | — |
| <span className="hbs-f hbs-e1">`0051 UN`</span><span className="hbs-nr">00050</span> | UN/CEFACT | — | X | — |
| <span className="hbs-f hbs-e1">`0057 1.1a`</span><span className="hbs-nr">00060</span> | Version number of the underlying BDEW message description | — | X | — |
| <span className="hbs-g hbs-e0">**BGM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1001 4`</span><span className="hbs-nr">00070</span> | Check report | — | X | — |
| <span className="hbs-f hbs-e1">`1004`</span><span className="hbs-nr">00080</span> | Document number | — | X | — |
| <span className="hbs-g hbs-e0">**DTM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`2005 137`</span><span className="hbs-nr">00090</span> | Document-/message date/time | — | X | — |
| <span className="hbs-f hbs-e1">`2380`</span><span className="hbs-nr">00100</span> | Date or time or time span, value | — | X | <span className="hbs-marke">[931]</span> <span className="hbs-marke">[494]</span> |
| <span className="hbs-f hbs-e1">`2379 303`</span><span className="hbs-nr">00110</span> | CCYYMMDDHHMMZZZ | — | X | — |
| <span className="hbs-g hbs-e0">**SG2.NAD**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3035 MR`</span><span className="hbs-nr">00120</span> | Message recipient | — | X | — |
| <span className="hbs-f hbs-e1">`3039`</span><span className="hbs-nr">00130</span> | MP-ID | — | X | <span className="hbs-marke">[14]</span> |
| <span className="hbs-f hbs-e1">`3055 9`</span><span className="hbs-nr">00140</span> | GS1 | — | X | — |
| <span className="hbs-f hbs-e1">`3055 293`</span><span className="hbs-nr">00150</span> | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| <span className="hbs-g hbs-e0">**SG2.NAD**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3035 MS`</span><span className="hbs-nr">00160</span> | Document-/message sender or sender | — | X | — |
| <span className="hbs-f hbs-e1">`3039`</span><span className="hbs-nr">00170</span> | MP-ID | — | X | <span className="hbs-marke">[14]</span> |
| <span className="hbs-f hbs-e1">`3055 9`</span><span className="hbs-nr">00180</span> | GS1 | — | X | — |
| <span className="hbs-f hbs-e1">`3055 293`</span><span className="hbs-nr">00190</span> | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| <span className="hbs-g hbs-e0">**SG3.DOC**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1001 23`</span><span className="hbs-nr">00200</span> | Status information | — | X | — |
| <span className="hbs-f hbs-e1">`1004`</span><span className="hbs-nr">00210</span> | Transaction number | — | X | — |
| <span className="hbs-g hbs-e0">**SG4.RFF**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1153 Z13`</span><span className="hbs-nr">00220</span> | Check identifier | — | X | — |
| <span className="hbs-f hbs-e1">`1154 23011`</span><span className="hbs-nr">00230</span> | WiM / information notification (fault report) from the MSB of the MaLo | — | X | — |
| <span className="hbs-g hbs-e0">**SG7.LIN**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1082`</span><span className="hbs-nr">00240</span> | Line item number | — | X | <span className="hbs-marke">[908]</span> <span className="hbs-marke">[511]</span> |
| <span className="hbs-g hbs-e0">**SG7.DTM**</span> | — | — | May | — |
| <span className="hbs-f hbs-e1">`2005 163`</span><span className="hbs-nr">00250</span> | Processing, start date/time | — | X | — |
| <span className="hbs-f hbs-e1">`2380`</span><span className="hbs-nr">00260</span> | Date or time or time span, value | — | X | (<span className="hbs-marke">[931]</span> <span className="hbs-marke">[13]</span> ∧ <span className="hbs-marke">[495]</span>) ⊻ (<span className="hbs-marke">[495]</span> ∧ <span className="hbs-marke">[515]</span>) |
| <span className="hbs-f hbs-e1">`2379 102`</span><span className="hbs-nr">00270</span> | CCYYMMDD | — | X | — |
| <span className="hbs-f hbs-e1">`2379 303`</span><span className="hbs-nr">00280</span> | CCYYMMDDHHMMZZZ | — | X | — |
| <span className="hbs-g hbs-e0">**SG7.DTM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`2005 292`</span><span className="hbs-nr">00290</span> | Date/time of the completed service (work), planned | — | X | — |
| <span className="hbs-f hbs-e1">`2380`</span><span className="hbs-nr">00300</span> | Date or time or time span, value | — | X | <span className="hbs-marke">[931]</span> <span className="hbs-marke">[13]</span> |
| <span className="hbs-f hbs-e1">`2379 102`</span><span className="hbs-nr">00310</span> | CCYYMMDD | — | X | — |
| <span className="hbs-f hbs-e1">`2379 303`</span><span className="hbs-nr">00320</span> | CCYYMMDDHHMMZZZ | — | X | — |
| <span className="hbs-g hbs-e0">**SG7.STS**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`9015 Z06`</span><span className="hbs-nr">00330</span> | Device status | — | X | — |
| <span className="hbs-f hbs-e1">`4405 Z10`</span><span className="hbs-nr">00340</span> | faulty | — | X | — |
| <span className="hbs-g hbs-e0">**SG7.FTX**</span> | — | — | May | — |
| <span className="hbs-f hbs-e1">`4451 AAO`</span><span className="hbs-nr">00350</span> | Error description (free text) | — | X | — |
| <span className="hbs-f hbs-e1">`4440`</span><span className="hbs-nr">00360</span> | Free text | — | X | — |
| <span className="hbs-g hbs-e0">**SG8.NAD**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3035 DP`</span><span className="hbs-nr">00370</span> | Supply address | — | X | — |
| <span className="hbs-g hbs-e0">**SG8.LOC**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3227 172`</span><span className="hbs-nr">00380</span> | Reporting point | — | X | — |
| <span className="hbs-f hbs-e1">`3225`</span><span className="hbs-nr">00390</span> | Identifier | — | X | <span className="hbs-marke">[950]</span> <span className="hbs-marke">[510]</span> |
| <span className="hbs-g hbs-e0">**SG8.RFF**</span> | — | — | Must | <span className="hbs-marke">[4]</span> ⊻ <span className="hbs-marke">[5]</span> |
| <span className="hbs-f hbs-e1">`1153 Z21`</span><span className="hbs-nr">00400</span> | assigned metering location | — | X | — |
| <span className="hbs-f hbs-e1">`1154`</span><span className="hbs-nr">00410</span> | ID of a metering location | — | X | <span className="hbs-marke">[951]</span> <span className="hbs-marke">[509]</span> |
| <span className="hbs-g hbs-e0">**UNT**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`0074`</span><span className="hbs-nr">00420</span> | Number of segments in a message | — | X | — |
| <span className="hbs-f hbs-e1">`0062`</span><span className="hbs-nr">00430</span> | Message reference number | — | X | — |

</div>

</Handbuchsatz>

### Conditions of this table

The free text of the 14 conditions referenced by the rows above. All conditions of the message type are listed in the [condition index INSRPT](/en/referenz/202610/ahb-bedingungen/INSRPT).

<div className="maco-tabellenrahmen">

| Marker | Condition |
|---|---|
| **[4]** | If MP-ID in SG2 NAD+MR in the role NB |
| **[5]** | If MP-ID in SG2 NAD+MR in the role LF |
| **[13]** | If DE2379 = 303 |
| **[14]** | Only MP-ID from the electricity division |
| **[494]** | The date stated here must be the point in time at which the document was created, or a point in time before that |
| **[495]** | The point in time must be ≤ the value in DE2380 of DTM+137 |
| **[509]** | Note: Use of the ID of the metering location |
| **[510]** | Note: Use of the ID of the market location |
| **[511]** | Note: The numbering starts at 1 in every document |
| **[515]** | Note: "≤ the value in DE2380 of DTM+137" means that the day stated there must be ≥ the day stated in this DTM if code 102 is entered in DE2379. |
| **[908]** | Format: possible values: 1 to n |
| **[931]** | Format: ZZZ = +00 |
| **[950]** | Format: market location ID |
| **[951]** | Format: Metering point identifier |

</div>

## Example message

### Example 1

<div data-maco="beispielfall" className="maco-beispielfall">

<Beispielnachricht>

```text title="EDIFACT"
UNA:+.? '
UNB+UNOC:3+9904446000007:500+9900321000005:500+{{date}}:{{time}}+LGO8FPVF'
UNH+UNHLGGEOGSZ+INSRPT:D:10A:UN:1.1a'
BGM+4+BGMLGO2Q0VF'
DTM+137:202303301547?+00:303'
NAD+MR+9900321000005::293'
NAD+MS+9904446000007::293'
DOC+23+202303301531'
RFF+Z13:23011'
LIN+1'
DTM+163:202303301547?+00:303'
DTM+292:202303301547?+00:303'
STS+Z06+Z10'
FTX+AAO+++Test123456'
NAD+DP'
LOC+172+50074561222'
RFF+Z21:DE0032106765712000000000000000054'
UNT+16+UNHLGGEOGSZ'
UNZ+1+LGO8FPVF'
```

```json title="BO4E-JSON"
[
  {
    "businessKey": "<businessKey>",
    "processDate": null,
    "dataSource": "OUTBOUND",
    "version": 1,
    "edifactVersion": 202610,
    "data": {
      "stammdaten": {
        "STATUSMITTEILUNG": [
          {
            "boTyp": "STATUSMITTEILUNG",
            "versionStruktur": "1",
            "positionsdaten": [
              {
                "positionsnummer": 1,
                "verwendungAb": "2023-03-30T15:47:00Z",
                "enddatum": "2023-03-30T15:47:00Z",
                "auftragsstatus": "GESTOERT",
                "fehlerbeschreibung": {
                  "beschreibung1": "Test123456"
                },
                "lokationsId": "50074561222",
                "referenzMelo": "DE0032106765712000000000000000054"
              }
            ]
          }
        ]
      },
      "transaktionsdaten": {
        "datenaustauschreferenz": "LGO8FPVF",
        "sparte": "STROM",
        "vorgangsnummer": "202303301531",
        "pruefidentifikator": "23011",
        "absender": {
          "boTyp": "MARKTTEILNEHMER",
          "versionStruktur": "1",
          "marktrolle": "MSB",
          "rollencodenummer": "9904446000007",
          "rollencodetyp": "BDEW"
        },
        "empfaenger": {
          "boTyp": "MARKTTEILNEHMER",
          "versionStruktur": "1",
          "marktrolle": "NB",
          "rollencodenummer": "9900321000005",
          "rollencodetyp": "BDEW"
        },
        "dokumentennummer": "BGMLGO2Q0VF",
        "kategorie": "4",
        "nachrichtendatum": "2023-03-30T15:47:00Z",
        "nachrichtenreferenznummer": "UNHLGGEOGSZ"
      },
      "zusatzdaten": {}
    }
  }
]
```

</Beispielnachricht>

*Source: [`1.edi`](https://github.com/conuti-gmbh/maco-edi-testfiles/blob/main/inbound/v202610/insrpt/23011/1.edi) · [`1.json`](https://github.com/conuti-gmbh/maco-edi-testfiles/blob/main/outbound/v202610/insrpt/23011/1.json)*

<Testdateien edi="/testdaten/202610/insrpt/23011/1.edi" json="/testdaten/202610/insrpt/23011/1.json" />

</div>

### Example 2

<div data-maco="beispielfall" className="maco-beispielfall">

<Beispielnachricht>

```text title="EDIFACT"
UNA:+.? '
UNB+UNOC:3+9904446000007:500+9900321000005:500+{{date}}:{{time}}+LGO8FPVF'
UNH+UNHLGGEOGSZ+INSRPT:D:10A:UN:1.1a'
BGM+4+BGMLGO2Q0VF'
DTM+137:202303301547?+00:303'
NAD+MR+9900321000005::293'
NAD+MS+9904446000007::293'
DOC+23+202303301531'
RFF+Z13:23011'
LIN+1'
DTM+292:202303301547?+00:303'
STS+Z06+Z10'
NAD+DP'
LOC+172+50074561222'
RFF+Z21:DE0032106765712000000000000000054'
UNT+14+UNHLGGEOGSZ'
UNZ+1+LGO8FPVF'
```

```json title="BO4E-JSON"
[
  {
    "businessKey": "<businessKey>",
    "processDate": null,
    "dataSource": "OUTBOUND",
    "version": 1,
    "edifactVersion": 202610,
    "data": {
      "stammdaten": {
        "STATUSMITTEILUNG": [
          {
            "boTyp": "STATUSMITTEILUNG",
            "versionStruktur": "1",
            "positionsdaten": [
              {
                "positionsnummer": 1,
                "enddatum": "2023-03-30T15:47:00Z",
                "auftragsstatus": "GESTOERT",
                "lokationsId": "50074561222",
                "referenzMelo": "DE0032106765712000000000000000054"
              }
            ]
          }
        ]
      },
      "transaktionsdaten": {
        "datenaustauschreferenz": "LGO8FPVF",
        "sparte": "STROM",
        "vorgangsnummer": "202303301531",
        "pruefidentifikator": "23011",
        "absender": {
          "boTyp": "MARKTTEILNEHMER",
          "versionStruktur": "1",
          "marktrolle": "MSB",
          "rollencodenummer": "9904446000007",
          "rollencodetyp": "BDEW"
        },
        "empfaenger": {
          "boTyp": "MARKTTEILNEHMER",
          "versionStruktur": "1",
          "marktrolle": "NB",
          "rollencodenummer": "9900321000005",
          "rollencodetyp": "BDEW"
        },
        "dokumentennummer": "BGMLGO2Q0VF",
        "kategorie": "4",
        "nachrichtendatum": "2023-03-30T15:47:00Z",
        "nachrichtenreferenznummer": "UNHLGGEOGSZ"
      },
      "zusatzdaten": {}
    }
  }
]
```

</Beispielnachricht>

*Source: [`2.edi`](https://github.com/conuti-gmbh/maco-edi-testfiles/blob/main/inbound/v202610/insrpt/23011/2.edi) · [`2.json`](https://github.com/conuti-gmbh/maco-edi-testfiles/blob/main/outbound/v202610/insrpt/23011/2.json)*

<Testdateien edi="/testdaten/202610/insrpt/23011/2.edi" json="/testdaten/202610/insrpt/23011/2.json" />

</div>

## Belongs to these role views

The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are **LF**, **NB**, **MSB** and **ÜNB**.

<div className="maco-tabellenrahmen">

| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | [Fault rectification in the metering location](/en/prozessdoku/202610/LF/WiM-Teil2-stoerungsbehebung-in-der-messlokation) | WiM electricity part 2 | Electricity | Step 4 |
| LF | LF | [Fault rectification in the metering location](/en/prozessdoku/202610/LF/WiM-Teil2-stoerungsbehebung-in-der-messlokation) | WiM electricity part 2 | Electricity | Step 5 |
| LF | LF | [Fault rectification in the metering location](/en/prozessdoku/202610/LF/WiM-Teil2-stoerungsbehebung-in-der-messlokation) | WiM electricity part 2 | Electricity | Step 6 |
| NB | NB | [Fault rectification in the metering location](/en/prozessdoku/202610/NB/WiM-Teil2-stoerungsbehebung-in-der-messlokation) | WiM electricity part 2 | Electricity | Step 4 |
| NB | NB | [Fault rectification in the metering location](/en/prozessdoku/202610/NB/WiM-Teil2-stoerungsbehebung-in-der-messlokation) | WiM electricity part 2 | Electricity | Step 5 |
| NB | NB | [Fault rectification in the metering location](/en/prozessdoku/202610/NB/WiM-Teil2-stoerungsbehebung-in-der-messlokation) | WiM electricity part 2 | Electricity | Step 6 |
| MSB | MSB-MALO | [Fault rectification in the metering location](/en/prozessdoku/202610/MSB--MSB-MALO/WiM-Teil2-stoerungsbehebung-in-der-messlokation) | WiM electricity part 2 | Electricity | Step 4 |
| MSB | MSB-MALO | [Fault rectification in the metering location](/en/prozessdoku/202610/MSB--MSB-MALO/WiM-Teil2-stoerungsbehebung-in-der-messlokation) | WiM electricity part 2 | Electricity | Step 5 |
| MSB | MSB-MALO | [Fault rectification in the metering location](/en/prozessdoku/202610/MSB--MSB-MALO/WiM-Teil2-stoerungsbehebung-in-der-messlokation) | WiM electricity part 2 | Electricity | Step 6 |
| MSB | MSB-MELO | [Fault rectification in the metering location](/en/prozessdoku/202610/MSB--MSB-MELO/WiM-Teil2-stoerungsbehebung-in-der-messlokation) | WiM electricity part 2 | Electricity | Step 4 |
| MSB | MSB-MELO | [Fault rectification in the metering location](/en/prozessdoku/202610/MSB--MSB-MELO/WiM-Teil2-stoerungsbehebung-in-der-messlokation) | WiM electricity part 2 | Electricity | Step 5 |
| MSB | MSB-MELO | [Fault rectification in the metering location](/en/prozessdoku/202610/MSB--MSB-MELO/WiM-Teil2-stoerungsbehebung-in-der-messlokation) | WiM electricity part 2 | Electricity | Step 6 |
| ÜNB | ÜNB | [Fault rectification in the metering location](/en/prozessdoku/202610/UENB/WiM-Teil2-stoerungsbehebung-in-der-messlokation) | WiM electricity part 2 | Electricity | Step 4 |
| ÜNB | ÜNB | [Fault rectification in the metering location](/en/prozessdoku/202610/UENB/WiM-Teil2-stoerungsbehebung-in-der-messlokation) | WiM electricity part 2 | Electricity | Step 5 |
| ÜNB | ÜNB | [Fault rectification in the metering location](/en/prozessdoku/202610/UENB/WiM-Teil2-stoerungsbehebung-in-der-messlokation) | WiM electricity part 2 | Electricity | Step 6 |

</div>

## Business classification

<div className="maco-tabellenrahmen">

| Attribute | Value |
|---|---|
| Use case (AHB) | Information notification |
| AHB | INSRPT AHB |
| Transmission channel | AS4 |

</div>

:::caution{title="This check identifier is used in 3 contexts"}

Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.

:::

<div className="maco-tabellenrahmen">

| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| WiM electricity part 2 | Fault rectification in the metering location | MSB (corresponds to MSB on the object market location) → NB | Information about fault at affected market location |
| WiM electricity part 2 | Fault rectification in the metering location | MSB (corresponds to MSB on the object market location) → LF | Information about fault at affected market location |
| WiM electricity part 2 | Fault rectification in the metering location | MSB (corresponds to MSB on the object market location) → ÜNB | Information about fault at affected market location |

</div>

## Transaction and responses

**Role of this check identifier: request.** Basis: the transaction data carry neither `antwortstatus` nor `antwortstatusCodeliste`, and neither the title nor the action of the Prüfi table begins with “response” or “response message”.

**Responses:** No response of this format version names this check identifier as a reference — neither explicitly in the Prüfi table nor via the step sequence. That does not mean there is none; it means that the sources do not record one.

**Check identifiers of the same AHB table:** No other check identifier of message type INSRPT has the same row structure in this version.

<Hinweisbereich>

An **\*** after a field or group name marks a **mandatory field** or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.

The status column carries two vocabularies because the manual answers two questions: on a **group row**, *Muss*, *Soll* or *Kann* states whether the EDIFACT segment must be present; on a **field row**, *X* states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.

For this check identifier, the application handbook lists **59 rows**. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.

The **Condition** column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.

The test data contains 2 transactions for this check identifier under the message type `insrpt`. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.

:::note{title="Placeholder from the test data set"}

The test data set carries placeholders instead of valid values: `{{date}}` and `{{time}}` in the UNB interchange envelope of every EDIFACT file. **The page replaces these on call with the current date and the current time** — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.

`<businessKey>` stays in place. It is not a time value, and an invented key would look like a valid one.

:::

</Hinweisbereich>