# Check identifier 13017 — Meter reading (Electricity)

<span hidden data-pagefind-meta={"title:Check identifier 13017 — Meter reading (electricity) · MSCONS · Format version 202610"} />

Check identifier **13017** · EDIFACT message type **MSCONS** · Format version **202610**

## Data structure

<Handbuchsatz>

<div className="maco-tabellenrahmen">

| Structure (BO4E) | Description | Format | <span className="hbs-p" title="Zählerstand (Strom)">13017</span> | Condition |
|---|---|---|---|---|
| <span className="hbs-g hbs-e0">**stammdaten** <span className="hbs-pflicht">\*</span></span> | — | object | Must | — |
| <span className="hbs-g hbs-e1">**ENERGIEMENGE** <span className="hbs-liste">[ ]</span> <span className="hbs-pflicht">\*</span></span> | — | object[] | Must | — |
| <span className="hbs-f hbs-e2">[konfiguration](/en/bo4e/202610/bo/Energiemenge#konfiguration)</span> <AhbTabelle pruefid="13017" format="MSCONS" fv="202610" zeile={50} segment="SG5.NAD+DP.SG6.LOC+172" /><span className="hbs-nr">00010</span> | konfiguration | string | X | — |
| <span className="hbs-f hbs-e2">[lokationsId](/en/bo4e/202610/bo/Energiemenge#lokationsid) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13017" format="MSCONS" fv="202610" zeile={50} segment="SG5.NAD+DP.SG6.LOC+172" /><span className="hbs-nr">00020</span> | Unique number of the market location or of the metering location to which the energy quantity belongs | string | X | — |
| <span className="hbs-g hbs-e2">**energieverbrauch** <span className="hbs-liste">[ ]</span> <span className="hbs-pflicht">\*</span></span> | — | object[] | Must | — |
| <span className="hbs-f hbs-e3">[ablesedatum](/en/bo4e/202610/com/Verbrauch#ablesedatum)</span> <AhbTabelle pruefid="13017" format="MSCONS" fv="202610" zeile={69} segment="SG5.NAD+DP.SG6.LOC+172.SG9.LIN.SG10.QTY.DTM+9" /><span className="hbs-nr">00030</span> | ablesedatum | string (date-time) | X | — |
| <span className="hbs-f hbs-e3">[ausfuehrungszeitpunkt](/en/bo4e/202610/com/Verbrauch#ausfuehrungszeitpunkt)</span> <AhbTabelle pruefid="13017" format="MSCONS" fv="202610" zeile={78} segment="SG5.NAD+DP.SG6.LOC+172.SG9.LIN.SG10.QTY.DTM+60" /><span className="hbs-nr">00040</span> | ausfuehrungszeitpunkt | string (date-time) | X | — |
| <span className="hbs-f hbs-e3">[messwertstatus](/en/bo4e/202610/com/Verbrauch#messwertstatus) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13017" format="MSCONS" fv="202610" zeile={64} segment="SG5.NAD+DP.SG6.LOC+172.SG9.LIN.SG10.QTY" /><span className="hbs-nr">00050</span> | The status of a meter reading | [Enum Messwertstatus](/en/bo4e/202610/enum/Messwertstatus) | Must | — |
| <span className="hbs-w hbs-e4">`ABGELESEN`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`ERSATZWERT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`VORSCHLAGSWERT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`NICHT_VERWENDBAR`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`PROGNOSEWERT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`ENERGIEMENGESUMMIERT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`VOLAEUFIGERWERT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`FEHLT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`ANGABE_FUER_LIEFERSCHEIN`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`GRUNDLAGE_POG_ERMITTLUNG`</span> | — | — | Must | — |
| <span className="hbs-f hbs-e3">[nutzungszeitpunkt](/en/bo4e/202610/com/Verbrauch#nutzungszeitpunkt) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13017" format="MSCONS" fv="202610" zeile={74} segment="SG5.NAD+DP.SG6.LOC+172.SG9.LIN.SG10.QTY.DTM+7" /><span className="hbs-nr">00060</span> | nutzungszeitpunkt | string (date-time) | X | — |
| <span className="hbs-f hbs-e3">[obiskennzahl](/en/bo4e/202610/com/Verbrauch#obiskennzahl) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13017" format="MSCONS" fv="202610" zeile={61} segment="SG5.NAD+DP.SG6.LOC+172.SG9.LIN.PIA+5" /><span className="hbs-nr">00070</span> | obiskennzahl | string | X | — |
| <span className="hbs-f hbs-e3">[position](/en/bo4e/202610/com/Verbrauch#position) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13017" format="MSCONS" fv="202610" zeile={58} segment="SG5.NAD+DP.SG6.LOC+172.SG9.LIN" /><span className="hbs-nr">00080</span> | position | integer | Must | — |
| <span className="hbs-f hbs-e3">[wert](/en/bo4e/202610/com/Verbrauch#wert) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13017" format="MSCONS" fv="202610" zeile={64} segment="SG5.NAD+DP.SG6.LOC+172.SG9.LIN.SG10.QTY" /><span className="hbs-nr">00090</span> | wert | number (float) | Must | — |
| <span className="hbs-g hbs-e3">**statuszusatzinformationen** <span className="hbs-liste">[ ]</span></span> | — | object[] | May | — |
| <span className="hbs-f hbs-e4">[art](/en/bo4e/202610/com/StatusZusatzInformation#art)</span> <AhbTabelle pruefid="13017" format="MSCONS" fv="202610" zeile={91} segment="SG5.NAD+DP.SG6.LOC+172.SG9.LIN.SG10.QTY.STS+Z32" /><span className="hbs-nr">00100</span> | Status type | [Enum StatusArt](/en/bo4e/202610/enum/StatusArt) | X | — |
| <span className="hbs-w hbs-e5">`PLAUSIBILISIERUNGSHINWEIS`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`ERSATZWERTBILDUNGSVERFAHREN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`KORREKTURGRUND`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`GRUND_ERSATZWERTBILDUNGSVERFAHREN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`GASQUALITAET`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`MESSKLASSIFIZIERUNG`</span> | — | — | X | — |
| <span className="hbs-f hbs-e4">[status](/en/bo4e/202610/com/StatusZusatzInformation#status)</span> <AhbTabelle pruefid="13017" format="MSCONS" fv="202610" zeile={91} segment="SG5.NAD+DP.SG6.LOC+172.SG9.LIN.SG10.QTY.STS+Z32" /><span className="hbs-nr">00110</span> | Status | [Enum Status](/en/bo4e/202610/enum/Status) | X | — |
| <span className="hbs-w hbs-e5">`KUNDENSELBSTABLESUNG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`LEERSTAND`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`REALER_ZAEHLERUEBERLAUF_GEPRUEFT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`PLAUSIBEL_WG_KONTROLLABLESUNG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`PLAUSIBEL_WG_KUNDENHINWEIS`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`AUSTAUSCH_DES_ERSATZWERTES`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`RECHENWERT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`BASIS_MME`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`VERGLEICHSMESSUNG_GEEICHT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`VERGLEICHSMESSUNG_NICHT_GEEICHT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`MESSWERTNACHBILDUNG_AUS_GEEICHTEN_WERTEN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`MESSWERTNACHBILDUNG_AUS_NICHT_GEEICHTEN_WERTEN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`INTERPOLATION`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`HALTEWERT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`BILANZIERUNG_NETZABSCHNITT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`HISTORISCHE_MESSWERTE`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`STATISTISCHE_METHODE`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`AUFTEILUNG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`VERWENDUNG_VON_WERTEN_DES_STOERMENGENZAEHLWERKS`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`UMGANGS_UND_KORREKTURMENGEN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`ANGABEN_MESSLOKATION`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`KEIN_ZUGANG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`KOMMUNIKATIONSSTOERUNG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`NETZAUSFALL`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`SPANNUNGSAUSFALL`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`STATUS_GERAETEWECHSEL`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`KALIBRIERUNG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`GERAET_ARBEITET_AUSSERHALB_DER_BETRIEBSBEDINGUNGEN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`MESSEINRICHTUNG_GESTOERT_DEFEKT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`UNSICHERHEIT_MESSUNG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`BERUECKSICHTIGUNG_STOERMENGENZAEHLWERK`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`MENGENUMWERTUNG_VOLLSTAENDIG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`UHRZEIT_GESTELLT_SYNCHRONISATION`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`MESSWERT_UNPLAUSIBEL`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`FALSCHER_WANDLERFAKTOR`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`FEHLERHAFTE_ABLESUNG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`AENDERUNG_DER_BERECHNUNG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`UMBAU_DER_MESSLOKATION`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`DATENBEARBEITUNGSFEHLER`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`BRENNWERTKORREKTUR`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`Z_ZAHL_KORREKTUR`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`STOERUNG_DEFEKT_MESSEINRICHTUNG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`AENDERUNG_TARIFSCHALTZEITEN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`TARIFSCHALTGERAET_DEFEKT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`IMPULSWERTIGKEIT_NICHT_AUSREICHEND`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`ENERGIEMENGE_IN_UNGEMESSENEM_ZEITINTERVALL`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`ENERGIEMENGE_AUS_DEM_UNGEPAIRTEN_ZEITINTERVALL`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`WARTUNGSARBEITEN_AN_GEEICHTEM_MESSGERAET`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`GESTOERTE_WERTE`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`WARTUNGSARBEITEN_AN_EICHRECHTSKONFORMEN_MESSGERAETEN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`KONSISTENZ_UND_SYNCHRONPRUEFUNG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`GRUND_ANGABEN_MESSLOKATION`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`ANFORDERUNG_IN_DIE_VERGANGENHEIT_ZUM_ANGEFORDERTEN_ZEITPUNKT_LIEGT_KEIN_WERT_VOR`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`UMSTELLUNG_GASQUALITAET`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`ZAEHLERSTAND_ZUM_BEGINN_DER_ANGEGEBENEN_ENERGIEMENGE_VORHANDEN_UND_KOMMUNIZIERT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`ZAEHLERSTAND_ZUM_ENDE_DER_ANGEGEBENEN_ENERGIEMENGE_VORHANDEN_UND_KOMMUNIZIERT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`ZAEHLERSTAND_ZUM_BEGINN_DER_ANGEGEBENEN_ENERGIEMENGE_NICHT_VORHANDEN_DA_MENGENABGRENZUNG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`ZAEHLERSTAND_ZUM_ENDE_DER_ANGEGEBENEN_ENERGIEMENGE_NICHT_VORHANDEN_DA_MENGENABGRENZUNG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`GESCHEITERT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`AUSGEBAUT`</span> | — | — | X | — |
| <span className="hbs-g hbs-e1">**ZAEHLER** <span className="hbs-liste">[ ]</span></span> | — | object[] | May | — |
| <span className="hbs-f hbs-e2">[zaehlernummer](/en/bo4e/202610/bo/Zaehler#zaehlernummer)</span> <AhbTabelle pruefid="13017" format="MSCONS" fv="202610" zeile={53} segment="SG5.NAD+DP.SG6.LOC+172.SG7.RFF+MG" /><span className="hbs-nr">00120</span> | Numbering of the meter, assigned by the metering point operator | string | X | — |
| <span className="hbs-g hbs-e0">**transaktionsdaten** <span className="hbs-pflicht">\*</span></span> | — | object | Must | — |
| <span className="hbs-f hbs-e1">[anfrageReferenz](/en/bo4e/202610/cdoc/Transaktionsdaten#anfragereferenz)</span> <AhbTabelle pruefid="13017" format="MSCONS" fv="202610" zeile={30} segment="SG1.RFF+AGI" /><span className="hbs-nr">00130</span> | Application number / RFF+AGI | string | X | — |
| <span className="hbs-f hbs-e1">[dokumentennummer](/en/bo4e/202610/cdoc/Transaktionsdaten#dokumentennummer) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13017" format="MSCONS" fv="202610" zeile={21} segment="BGM" /><span className="hbs-nr">00140</span> | EDIFACT reference from the BGM segment / BGM | string | Must | — |
| <span className="hbs-f hbs-e1">[kategorie](/en/bo4e/202610/cdoc/Transaktionsdaten#kategorie) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13017" format="MSCONS" fv="202610" zeile={21} segment="BGM" /><span className="hbs-nr">00150</span> | Qualifier from the beginning of the EDIFACT message / BGM | string | Must | — |
| <span className="hbs-f hbs-e1">[nachrichtendatum](/en/bo4e/202610/cdoc/Transaktionsdaten#nachrichtendatum) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13017" format="MSCONS" fv="202610" zeile={26} segment="DTM+137" /><span className="hbs-nr">00160</span> | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| <span className="hbs-f hbs-e1">[nachrichtenfunktion](/en/bo4e/202610/cdoc/Transaktionsdaten#nachrichtenfunktion) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13017" format="MSCONS" fv="202610" zeile={21} segment="BGM" /><span className="hbs-nr">00170</span> | Message function code / BGM | string | Must | — |
| <span className="hbs-f hbs-e1">[nachrichtenreferenznummer](/en/bo4e/202610/cdoc/Transaktionsdaten#nachrichtenreferenznummer) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13017" format="MSCONS" fv="202610" zeile={14} segment="UNH" /><span className="hbs-nr">00180</span> | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| <span className="hbs-f hbs-e1">[pruefidentifikator](/en/bo4e/202610/cdoc/Transaktionsdaten#pruefidentifikator) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13017" format="MSCONS" fv="202610" zeile={33} segment="SG1.RFF+Z13" /><span className="hbs-nr">00190</span> | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| <span className="hbs-g hbs-e1">**absender** <span className="hbs-pflicht">\*</span></span> | — | object | Must | — |
| <span className="hbs-f hbs-e2">[rollencodenummer](/en/bo4e/202610/bo/Marktteilnehmer#rollencodenummer) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13017" format="MSCONS" fv="202610" zeile={36} segment="SG2.NAD+MS" /><span className="hbs-nr">00200</span> | Specifies the code value of the market role. | string | X | — |
| <span className="hbs-f hbs-e2">[rollencodetyp](/en/bo4e/202610/bo/Marktteilnehmer#rollencodetyp) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13017" format="MSCONS" fv="202610" zeile={36} segment="SG2.NAD+MS" /><span className="hbs-nr">00210</span> | Indicates the type of the code. | [Enum Rollencodetyp](/en/bo4e/202610/enum/Rollencodetyp) | X | — |
| <span className="hbs-w hbs-e3">`BDEW`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`GS1`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`GLN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`DVGW`</span> | — | — | X | — |
| <span className="hbs-g hbs-e1">**empfaenger** <span className="hbs-pflicht">\*</span></span> | — | object | Must | — |
| <span className="hbs-f hbs-e2">[rollencodenummer](/en/bo4e/202610/bo/Marktteilnehmer#rollencodenummer) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13017" format="MSCONS" fv="202610" zeile={41} segment="SG2.NAD+MR" /><span className="hbs-nr">00220</span> | Specifies the code value of the market role. | string | X | — |
| <span className="hbs-f hbs-e2">[rollencodetyp](/en/bo4e/202610/bo/Marktteilnehmer#rollencodetyp) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13017" format="MSCONS" fv="202610" zeile={41} segment="SG2.NAD+MR" /><span className="hbs-nr">00230</span> | Indicates the type of the code. | [Enum Rollencodetyp](/en/bo4e/202610/enum/Rollencodetyp) | X | — |
| <span className="hbs-w hbs-e3">`BDEW`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`GS1`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`GLN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`DVGW`</span> | — | — | X | — |

</div>

</Handbuchsatz>

## Application handbook (AHB)

<Handbuchsatz>

<div className="maco-tabellenrahmen" data-maco="ahb-tabelle">

| Structure (EDIFACT) | Description | Format | <span className="hbs-p" title="Zählerstand (Strom)">13017</span> | Condition |
|---|---|---|---|---|
| <span className="hbs-g hbs-e0">**UNB**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`0001 UNOC`</span><span className="hbs-nr">00010</span> | UN/ECE character set C | — | X | — |
| <span className="hbs-f hbs-e1">`0002 3`</span><span className="hbs-nr">00020</span> | Version 3 | — | X | — |
| <span className="hbs-f hbs-e1">`0004`</span><span className="hbs-nr">00030</span> | MP-ID Sender | — | X | — |
| <span className="hbs-f hbs-e1">`0007 14`</span><span className="hbs-nr">00040</span> | GS1 | — | X | — |
| <span className="hbs-f hbs-e1">`0007 500`</span><span className="hbs-nr">00050</span> | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| <span className="hbs-f hbs-e1">`0010`</span><span className="hbs-nr">00060</span> | MP-ID recipient | — | X | — |
| <span className="hbs-f hbs-e1">`0007 14`</span><span className="hbs-nr">00070</span> | GS1 | — | X | — |
| <span className="hbs-f hbs-e1">`0007 500`</span><span className="hbs-nr">00080</span> | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| <span className="hbs-f hbs-e1">`0017`</span><span className="hbs-nr">00090</span> | Date of creation | — | X | — |
| <span className="hbs-f hbs-e1">`0019`</span><span className="hbs-nr">00100</span> | Time of creation | — | X | — |
| <span className="hbs-f hbs-e1">`0020`</span><span className="hbs-nr">00110</span> | Interchange control reference | — | X | <span className="hbs-marke">[918]</span> |
| <span className="hbs-f hbs-e1">`0026 VL`</span><span className="hbs-nr">00120</span> | Settlement list, meter reading | — | X | — |
| <span className="hbs-f hbs-e1">`0035 1`</span><span className="hbs-nr">00130</span> | Transmission file is a test | — | — | S <span className="hbs-marke">[155]</span> |
| <span className="hbs-g hbs-e0">**UNH**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`0062`</span><span className="hbs-nr">00140</span> | Message reference number | — | X | — |
| <span className="hbs-f hbs-e1">`0065 MSCONS`</span><span className="hbs-nr">00150</span> | Report on the consumption of measurable services | — | X | — |
| <span className="hbs-f hbs-e1">`0052 D`</span><span className="hbs-nr">00160</span> | Draft version | — | X | — |
| <span className="hbs-f hbs-e1">`0054 04B`</span><span className="hbs-nr">00170</span> | Edition 2004 - B | — | X | — |
| <span className="hbs-f hbs-e1">`0051 UN`</span><span className="hbs-nr">00180</span> | UN/CEFACT | — | X | — |
| <span className="hbs-f hbs-e1">`0057 2.5`</span><span className="hbs-nr">00190</span> | Version number of the underlying BDEW message description | — | X | — |
| <span className="hbs-g hbs-e0">**BGM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1001 7`</span><span className="hbs-nr">00200</span> | Process data report | — | X | — |
| <span className="hbs-f hbs-e1">`1004`</span><span className="hbs-nr">00210</span> | Document number | — | X | — |
| <span className="hbs-f hbs-e1">`1225 9`</span><span className="hbs-nr">00220</span> | Original | — | X | — |
| <span className="hbs-g hbs-e0">**DTM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`2005 137`</span><span className="hbs-nr">00230</span> | Document-/message date/time | — | X | — |
| <span className="hbs-f hbs-e1">`2380`</span><span className="hbs-nr">00240</span> | Date or time or time span, value | — | X | <span className="hbs-marke">[931]</span> <span className="hbs-marke">[494]</span> |
| <span className="hbs-f hbs-e1">`2379 303`</span><span className="hbs-nr">00250</span> | CCYYMMDDHHMMZZZ | — | X | — |
| <span className="hbs-g hbs-e0">**SG1.RFF**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1153 AGI`</span><span className="hbs-nr">00260</span> | Application number | — | X | — |
| <span className="hbs-f hbs-e1">`1154`</span><span className="hbs-nr">00270</span> | Reference number | — | X | (<span className="hbs-marke">[67]</span> ∧ (<span className="hbs-marke">[529]</span> ∨ <span className="hbs-marke">[553]</span>)) |
| <span className="hbs-g hbs-e0">**SG1.RFF**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1153 Z13`</span><span className="hbs-nr">00280</span> | Check identifier | — | X | — |
| <span className="hbs-f hbs-e1">`1154 13017`</span><span className="hbs-nr">00290</span> | Meas. val. meter reading (electricity) | — | X | — |
| <span className="hbs-g hbs-e0">**SG2.NAD**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3035 MS`</span><span className="hbs-nr">00300</span> | Document-/message sender or sender | — | X | — |
| <span className="hbs-f hbs-e1">`3039`</span><span className="hbs-nr">00310</span> | MP-ID | — | X | <span className="hbs-marke">[117]</span> |
| <span className="hbs-f hbs-e1">`3055 9`</span><span className="hbs-nr">00320</span> | GS1 | — | X | — |
| <span className="hbs-f hbs-e1">`3055 293`</span><span className="hbs-nr">00330</span> | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| <span className="hbs-g hbs-e0">**SG2.NAD**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3035 MR`</span><span className="hbs-nr">00340</span> | Message recipient | — | X | — |
| <span className="hbs-f hbs-e1">`3039`</span><span className="hbs-nr">00350</span> | MP-ID | — | X | <span className="hbs-marke">[117]</span> |
| <span className="hbs-f hbs-e1">`3055 9`</span><span className="hbs-nr">00360</span> | GS1 | — | X | — |
| <span className="hbs-f hbs-e1">`3055 293`</span><span className="hbs-nr">00370</span> | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| <span className="hbs-g hbs-e0">**UNS**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`0081 D`</span><span className="hbs-nr">00380</span> | Separation of header and detail section | — | X | — |
| <span className="hbs-g hbs-e0">**SG5.NAD**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3035 DP`</span><span className="hbs-nr">00390</span> | Supply address | — | X | — |
| <span className="hbs-g hbs-e0">**SG6.LOC**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3227 172`</span><span className="hbs-nr">00400</span> | Reporting point | — | X | — |
| <span className="hbs-f hbs-e1">`3225`</span><span className="hbs-nr">00410</span> | Designation | — | — | M <span className="hbs-marke">[131]</span> ∧ (<span className="hbs-marke">[951]</span> ∧ <span className="hbs-marke">[510]</span>) |
| <span className="hbs-g hbs-e0">**SG7.RFF**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1153 MG`</span><span className="hbs-nr">00420</span> | Device number | — | X | — |
| <span className="hbs-f hbs-e1">`1154`</span><span className="hbs-nr">00430</span> | Device number | — | X | — |
| <span className="hbs-g hbs-e0">**SG7.RFF**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1153 AGK`</span><span className="hbs-nr">00440</span> | Application reference number | — | X | — |
| <span className="hbs-f hbs-e1">`1154`</span><span className="hbs-nr">00450</span> | Configuration ID | — | X | <span className="hbs-marke">[567]</span> |
| <span className="hbs-g hbs-e0">**SG9.LIN**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1082`</span><span className="hbs-nr">00460</span> | Line item number | — | X | <span className="hbs-marke">[908]</span> |
| <span className="hbs-g hbs-e0">**SG9.PIA**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`4347 5`</span><span className="hbs-nr">00470</span> | Product identification | — | X | — |
| <span className="hbs-f hbs-e1">`7140`</span><span className="hbs-nr">00480</span> | Medium / OBIS code number | — | X | <span className="hbs-marke">[501]</span> ∧ <span className="hbs-marke">[566]</span> |
| <span className="hbs-f hbs-e1">`7143 SRW`</span><span className="hbs-nr">00490</span> | OBIS code | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.QTY**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`6063 220`</span><span className="hbs-nr">00500</span> | True value | — | X | — |
| <span className="hbs-f hbs-e1">`6063 67`</span><span className="hbs-nr">00510</span> | Substitute value | — | X | <span className="hbs-marke">[35]</span> ∨ (<span className="hbs-marke">[32]</span> ∧ <span className="hbs-marke">[77]</span>) |
| <span className="hbs-f hbs-e1">`6063 Z18`</span><span className="hbs-nr">00520</span> | Preliminary value | — | X | <span className="hbs-marke">[35]</span> ∧ <span className="hbs-marke">[113]</span> |
| <span className="hbs-f hbs-e1">`6060`</span><span className="hbs-nr">00530</span> | Quantity | — | X | <span className="hbs-marke">[902]</span> ∧ <span className="hbs-marke">[906]</span> |
| <span className="hbs-g hbs-e0">**SG10.DTM**</span> | — | — | Should | <span className="hbs-marke">[93]</span> ∧ <span className="hbs-marke">[128]</span> ∧ <span className="hbs-marke">[131]</span> ∧ <span className="hbs-marke">[569]</span> |
| <span className="hbs-f hbs-e1">`2005 9`</span><span className="hbs-nr">00540</span> | Handling/processing date/time | — | X | — |
| <span className="hbs-f hbs-e1">`2380`</span><span className="hbs-nr">00550</span> | Date or time or time span, value | — | X | (<span className="hbs-marke">[931]</span> <span className="hbs-marke">[111]</span> ∧ <span className="hbs-marke">[495]</span>) ⊻ (<span className="hbs-marke">[134]</span> ∧ <span className="hbs-marke">[135]</span>) |
| <span className="hbs-f hbs-e1">`2379 102`</span><span className="hbs-nr">00560</span> | CCYYMMDD | — | X | — |
| <span className="hbs-f hbs-e1">`2379 303`</span><span className="hbs-nr">00570</span> | CCYYMMDDHHMMZZZ | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.DTM**</span> | — | — | Must | <span className="hbs-marke">[569]</span> |
| <span className="hbs-f hbs-e1">`2005 7`</span><span className="hbs-nr">00580</span> | Effective date/time | — | X | — |
| <span className="hbs-f hbs-e1">`2380`</span><span className="hbs-nr">00590</span> | Date or time or time span, value | — | X | <span className="hbs-marke">[UB1]</span> ∧ <span className="hbs-marke">[495]</span> ∧ (<span className="hbs-marke">[130]</span> ∨ <span className="hbs-marke">[133]</span>) |
| <span className="hbs-f hbs-e1">`2379 303`</span><span className="hbs-nr">00600</span> | CCYYMMDDHHMMZZZ | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.DTM**</span> | — | — | Should | <span className="hbs-marke">[129]</span> ∧ <span className="hbs-marke">[569]</span> |
| <span className="hbs-f hbs-e1">`2005 60`</span><span className="hbs-nr">00610</span> | Design change date | — | X | — |
| <span className="hbs-f hbs-e1">`2380`</span><span className="hbs-nr">00620</span> | Date or time or time span, value | — | X | <span className="hbs-marke">[931]</span> <span className="hbs-marke">[495]</span> |
| <span className="hbs-f hbs-e1">`2379 303`</span><span className="hbs-nr">00630</span> | CCYYMMDDHHMMZZZ | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.STS**</span> | — | — | Should | (<span className="hbs-marke">[92]</span> ⊻ <span className="hbs-marke">[93]</span>) ∧ <span className="hbs-marke">[126]</span> |
| <span className="hbs-f hbs-e1">`9015 Z33`</span><span className="hbs-nr">00640</span> | Plausibility check note | — | X | — |
| <span className="hbs-f hbs-e1">`9013 Z83`</span><span className="hbs-nr">00650</span> | Customer self-reading | — | X | <span className="hbs-marke">[5P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z84`</span><span className="hbs-nr">00660</span> | Vacancy | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[5P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z85`</span><span className="hbs-nr">00670</span> | Actual meter overflow checked | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[5P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z86`</span><span className="hbs-nr">00680</span> | Plausible due to check reading | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[5P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z87`</span><span className="hbs-nr">00690</span> | Plausible due to customer information | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[5P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZC3`</span><span className="hbs-nr">00700</span> | Exchange of the substitute value | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[5P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZS2`</span><span className="hbs-nr">00710</span> | Value based on the modern measuring equipment | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-g hbs-e0">**SG10.STS**</span> | — | — | Must | <span className="hbs-marke">[92]</span> |
| <span className="hbs-f hbs-e1">`9015 Z32`</span><span className="hbs-nr">00720</span> | Substitute value formation procedure | — | X | — |
| <span className="hbs-f hbs-e1">`9013 Z88`</span><span className="hbs-nr">00730</span> | Comparative measurement (calibrated) | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z89`</span><span className="hbs-nr">00740</span> | Comparative measurement (not calibrated) | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z92`</span><span className="hbs-nr">00750</span> | Interpolation | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZJ2`</span><span className="hbs-nr">00760</span> | Statistical method | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-g hbs-e0">**SG10.STS**</span> | — | — | Should | <span className="hbs-marke">[127]</span> ∧ <span className="hbs-marke">[541]</span> |
| <span className="hbs-f hbs-e1">`9015 Z34`</span><span className="hbs-nr">00770</span> | Reason for correction | — | X | — |
| <span className="hbs-f hbs-e1">`9013 Z74`</span><span className="hbs-nr">00780</span> | no access | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z75`</span><span className="hbs-nr">00790</span> | Communication fault | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z76`</span><span className="hbs-nr">00800</span> | Grid outage | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z77`</span><span className="hbs-nr">00810</span> | Voltage failure | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z78`</span><span className="hbs-nr">00820</span> | Device replacement | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z79`</span><span className="hbs-nr">00830</span> | Calibration | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z80`</span><span className="hbs-nr">00840</span> | Device operates outside the operating conditions | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z81`</span><span className="hbs-nr">00850</span> | Measuring equipment faulty/defective | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z82`</span><span className="hbs-nr">00860</span> | Measurement uncertainty | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZA0`</span><span className="hbs-nr">00870</span> | Time set /synchronisation | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZA1`</span><span className="hbs-nr">00880</span> | Meter reading value implausible | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZA3`</span><span className="hbs-nr">00890</span> | Incorrect transformer factor | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[5P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZA4`</span><span className="hbs-nr">00900</span> | Incorrect reading | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[5P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZA5`</span><span className="hbs-nr">00910</span> | Change of the calculation | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[5P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZA6`</span><span className="hbs-nr">00920</span> | Conversion of the metering location | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[5P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZA7`</span><span className="hbs-nr">00930</span> | Data processing error | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[5P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZB0`</span><span className="hbs-nr">00940</span> | Fault / defect of measuring equipment | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[5P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZB9`</span><span className="hbs-nr">00950</span> | Change tariff switching times | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[5P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZC2`</span><span className="hbs-nr">00960</span> | Tariff switching device defective | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[5P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZC4`</span><span className="hbs-nr">00970</span> | Pulse value not sufficient | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-g hbs-e0">**SG10.STS**</span> | — | — | Must | <span className="hbs-marke">[92]</span> |
| <span className="hbs-f hbs-e1">`9015 Z40`</span><span className="hbs-nr">00980</span> | Reason for substitute value formation | — | X | — |
| <span className="hbs-f hbs-e1">`9013 Z74`</span><span className="hbs-nr">00990</span> | no access | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z75`</span><span className="hbs-nr">01000</span> | Communication fault | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z76`</span><span className="hbs-nr">01010</span> | Grid outage | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z77`</span><span className="hbs-nr">01020</span> | Voltage failure | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z78`</span><span className="hbs-nr">01030</span> | Device replacement | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z79`</span><span className="hbs-nr">01040</span> | Calibration | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z80`</span><span className="hbs-nr">01050</span> | Device operates outside the operating conditions | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z81`</span><span className="hbs-nr">01060</span> | Measuring equipment faulty/defective | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 Z82`</span><span className="hbs-nr">01070</span> | Measurement uncertainty | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZA0`</span><span className="hbs-nr">01080</span> | Time set /synchronisation | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZA1`</span><span className="hbs-nr">01090</span> | Meter reading value implausible | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZA3`</span><span className="hbs-nr">01100</span> | Incorrect transformer factor | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZA4`</span><span className="hbs-nr">01110</span> | Incorrect reading | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZA5`</span><span className="hbs-nr">01120</span> | Change of the calculation | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZA6`</span><span className="hbs-nr">01130</span> | Conversion of the metering location | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZA7`</span><span className="hbs-nr">01140</span> | Data processing error | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZB0`</span><span className="hbs-nr">01150</span> | Fault / defect of measuring equipment | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZB9`</span><span className="hbs-nr">01160</span> | Change tariff switching times | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZC2`</span><span className="hbs-nr">01170</span> | Tariff switching device defective | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZC4`</span><span className="hbs-nr">01180</span> | Pulse value not sufficient | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`9013 ZT8`</span><span className="hbs-nr">01190</span> | Request into the past; no value is available for the requested point in time. | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-g hbs-e0">**UNT**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`0074`</span><span className="hbs-nr">01200</span> | Number of segments in a message | — | X | — |
| <span className="hbs-f hbs-e1">`0062`</span><span className="hbs-nr">01210</span> | Message reference number | — | X | — |
| <span className="hbs-g hbs-e0">**UNZ**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`0036`</span><span className="hbs-nr">01220</span> | Interchange counter | — | X | — |
| <span className="hbs-f hbs-e1">`0020`</span><span className="hbs-nr">01230</span> | Interchange control reference | — | X | — |

</div>

</Handbuchsatz>

### Conditions of this table

The free text of the 38 conditions referenced by the rows above. All conditions of the message type are listed in the [condition index MSCONS](/en/referenz/202610/ahb-bedingungen/MSCONS).

<div className="maco-tabellenrahmen">

| Marker | Condition |
|---|---|
| **[32]** | if MP-ID in SG2 NAD+MS in the role NB |
| **[35]** | if MP-ID in SG2 NAD+MS in the role MSB |
| **[67]** | If this concerns the reference to a ORDERS |
| **[77]** | If MP-ID in SG2 NAD+MR of the RB HKN-R |
| **[92]** | If SG10 QTY DE6063 with value 67 is present |
| **[93]** | If SG10 QTY DE6063 with value 220 is present |
| **[111]** | If SG10 DTM+9 DE2379 with value 303 is present in the same segment |
| **[113]** | if SG7 RFF+AGK (configuration ID) is present |
| **[117]** | Only MP-ID from the electricity division |
| **[126]** | if plausibility check notices exist |
| **[127]** | if a correction reason has to be stated |
| **[128]** | If this concerns a meter reading which is not a reading due to a change to the metering equipment or its configuration (e.g. customer reading). |
| **[129]** | If this concerns a meter reading due to a change to the metering equipment or its configuration (e.g. device replacement). |
| **[130]** | If, within the same LIN segment and in addition to this segment (SG10 DTM+7 usage point in time), the SG10 DTM+60 (execution / change point in time) or the SG10 DTM+9 (reading date) is also present, the value of the difference between the later and the earlier point in time of the DTM segments may only be &lt; 24 hours. If the summer/winter time changeover takes place between the two points in time, the value of the difference may only be &lt; 25 hours. If the winter/summer time changeover takes place between the two points in time, the value of the difference may only be &lt; 23 hours. |
| **[131]** | if RFF+AGK (configuration ID) is not present |
| **[133]** | If, within the same LIN segment and in addition to this segment (SG10 DTM+7 usage point in time), the SG10 DTM+9 (reading date) with the code 102 in DE2379 is also present, the value of the difference between the value at position CCYYMMDD of the later and the earlier point in time of the DTM segments at position CCYYMMDD may only be 0 or 1 day. |
| **[134]** | If SG10 DTM+9 DE2379 with value 102 is present in the same segment |
| **[135]** | The value at position CCYYMMDD must be ≤ the value at position CCYYMMDD in DE2380 of DTM+137 |
| **[155]** | If the transmission file is exchanged for test purposes. |
| **[494]** | The date stated here must be the point in time at which the document was created, or a point in time before that. |
| **[495]** | The point in time must be ≤ the value in DE2380 of DTM+137 |
| **[501]** | Note: Only the values that are marked with the corresponding check identifier in the EDI@Energy code list of the OBIS codes and media are permitted. |
| **[510]** | Note: Use of the ID of the metering location |
| **[529]** | Note: Value from BGM+7 DE1004 of the ORDERS with which the request for meter reading values was made. |
| **[541]** | Note: A correction reason is to be specified if: 1. a preliminary value already transmitted to the MP is replaced by a substitute value after cancellation, or 2. a substitute value already transmitted to the MP is replaced by a substitute value after cancellation, or 3. a true value already transmitted to the MP is replaced by a substitute value after cancellation, or 4. a true value already transmitted to the MP is replaced by a true value after cancellation. |
| **[553]** | Note: Value from BGM+Z34 DE1004 of the ORDERS with which the complaint regarding values was made |
| **[566]** | Note: Only the values that were transmitted by the MSB in the previous master data exchange for this reporting point at the point in time are permitted. |
| **[567]** | Note: The configuration ID that was communicated in the previous master data exchange must be specified. |
| **[569]** | Note: If a metering location has several meter readings (e.g. HT/NT), this time specification is to be used and the SG9 LIN is to be repeated. |
| **[902]** | Format: Possible value: ≥ 0 |
| **[906]** | Format: max. 3 decimal places |
| **[908]** | Format: possible values: 1 to n |
| **[918]** | Format: Characters from the character set defined via UNOC, where only capital letters are permitted among the letters. |
| **[931]** | Format: ZZZ = +00 |
| **[951]** | Format: Metering point identifier |
| **[UB1]** | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |
| **[5P0..1]** | [93]  If SG10 QTY DE6063 with value 220 present |
| **[4P0..1]** | [92]  If SG10 QTY DE6063 with value 67 present |

</div>

## Example message

### Example 1

<div data-maco="beispielfall" className="maco-beispielfall">

<Beispielnachricht>

```text title="EDIFACT"
UNA:+.? '
UNB+UNOC:3+9907492000005:500+9904960000004:500+{{date}}:{{time}}+141757++VL'
UNH+137826+MSCONS:D:04B:UN:2.5'
BGM+7+137826BGM+9'
DTM+137:202610011100?+00:303'
RFF+Z13:13017'
NAD+MS+9907492000005::293'
NAD+MR+9904960000004::293'
UNS+D'
NAD+DP'
LOC+172+DE0073395252733953513649640711234'
RFF+MG:G12345678910'
LIN+1'
PIA+5+1-1?:1.8.0:SRW'
QTY+220:1234567.357'
DTM+9:202603011100?+00:303'
DTM+7:202603012300?+00:303'
STS+Z33++Z83'
UNT+17+137826'
UNZ+1+141757'
```

```json title="BO4E-JSON"
[
  {
    "businessKey": "<businessKey>",
    "processDate": null,
    "dataSource": "OUTBOUND",
    "version": 1,
    "edifactVersion": 202610,
    "data": {
      "stammdaten": {
        "ZAEHLER": [
          {
            "boTyp": "ZAEHLER",
            "versionStruktur": "1",
            "zaehlernummer": "G12345678910",
            "sparte": "STROM"
          }
        ],
        "ENERGIEMENGE": [
          {
            "boTyp": "ENERGIEMENGE",
            "versionStruktur": "1",
            "lokationsId": "DE0073395252733953513649640711234",
            "lokationsTyp": "MELO",
            "energieverbrauch": [
              {
                "messwertstatus": "ABGELESEN",
                "statuszusatzinformationen": [
                  {
                    "art": "PLAUSIBILISIERUNGSHINWEIS",
                    "status": "KUNDENSELBSTABLESUNG"
                  }
                ],
                "obiskennzahl": "1-1:1.8.0",
                "wert": 1234567.357,
                "nutzungszeitpunkt": "2026-03-01T23:00:00Z",
                "position": 1,
                "ablesedatum": "2026-03-01T11:00:00Z"
              }
            ]
          }
        ]
      },
      "transaktionsdaten": {
        "datenaustauschreferenz": "141757",
        "sparte": "STROM",
        "pruefidentifikator": "13017",
        "absender": {
          "boTyp": "MARKTTEILNEHMER",
          "versionStruktur": "1",
          "rollencodenummer": "9907492000005",
          "rollencodetyp": "BDEW"
        },
        "empfaenger": {
          "boTyp": "MARKTTEILNEHMER",
          "versionStruktur": "1",
          "marktrolle": "MSB",
          "rollencodenummer": "9904960000004",
          "rollencodetyp": "BDEW"
        },
        "dokumentennummer": "137826BGM",
        "kategorie": "7",
        "nachrichtenfunktion": "9",
        "nachrichtendatum": "2026-10-01T11:00:00Z",
        "nachrichtenreferenznummer": "137826",
        "typ": "VL"
      },
      "zusatzdaten": {}
    }
  }
]
```

</Beispielnachricht>

*Source: [`1.edi`](https://github.com/conuti-gmbh/maco-edi-testfiles/blob/main/inbound/v202610/mscons/13017/1.edi) · [`1.json`](https://github.com/conuti-gmbh/maco-edi-testfiles/blob/main/outbound/v202610/mscons/13017/1.json)*

<Testdateien edi="/testdaten/202610/mscons/13017/1.edi" json="/testdaten/202610/mscons/13017/1.json" />

</div>

### Example 2

<div data-maco="beispielfall" className="maco-beispielfall">

<Beispielnachricht>

```text title="EDIFACT"
UNA:+.? '
UNB+UNOC:3+9904446000007:500+9900321000005:500+{{date}}:{{time}}+121561++VL'
UNH+744163+MSCONS:D:04B:UN:2.5'
BGM+7+744163BGM+9'
DTM+137:202610011100?+00:303'
RFF+Z13:13017'
NAD+MS+9904446000007::293'
NAD+MR+9900321000005::293'
UNS+D'
NAD+DP'
LOC+172+DE0032106765712000000000000000037'
RFF+MG:EL001IK01013852469'
LIN+1'
PIA+5+1-0?:1.8.1:SRW'
QTY+67:1000'
DTM+7:202603252300?+00:303'
STS+Z32++Z92'
STS+Z40++Z74'
LIN+2'
PIA+5+1-0?:1.8.2:SRW'
QTY+67:11000'
DTM+7:202603252300?+00:303'
STS+Z32++Z92'
STS+Z40++Z74'
UNT+23+744163'
UNZ+1+121561'
```

```json title="BO4E-JSON"
[
  {
    "businessKey": "<businessKey>",
    "processDate": null,
    "dataSource": "OUTBOUND",
    "version": 1,
    "edifactVersion": 202610,
    "data": {
      "stammdaten": {
        "ZAEHLER": [
          {
            "boTyp": "ZAEHLER",
            "versionStruktur": "1",
            "zaehlernummer": "EL001IK01013852469",
            "sparte": "STROM"
          }
        ],
        "ENERGIEMENGE": [
          {
            "boTyp": "ENERGIEMENGE",
            "versionStruktur": "1",
            "lokationsId": "DE0032106765712000000000000000037",
            "lokationsTyp": "MELO",
            "energieverbrauch": [
              {
                "messwertstatus": "ERSATZWERT",
                "statuszusatzinformationen": [
                  {
                    "art": "ERSATZWERTBILDUNGSVERFAHREN",
                    "status": "INTERPOLATION"
                  },
                  {
                    "art": "GRUND_ERSATZWERTBILDUNGSVERFAHREN",
                    "status": "KEIN_ZUGANG"
                  }
                ],
                "obiskennzahl": "1-0:1.8.1",
                "wert": 1000.0,
                "nutzungszeitpunkt": "2026-03-25T23:00:00Z",
                "position": 1
              },
              {
                "messwertstatus": "ERSATZWERT",
                "statuszusatzinformationen": [
                  {
                    "art": "ERSATZWERTBILDUNGSVERFAHREN",
                    "status": "INTERPOLATION"
                  },
                  {
                    "art": "GRUND_ERSATZWERTBILDUNGSVERFAHREN",
                    "status": "KEIN_ZUGANG"
                  }
                ],
                "obiskennzahl": "1-0:1.8.2",
                "wert": 11000.0,
                "nutzungszeitpunkt": "2026-03-25T23:00:00Z",
                "position": 2
              }
            ],
            "referenzStammdatenmeldungMsb": "REF12345678"
          }
        ]
      },
      "transaktionsdaten": {
        "datenaustauschreferenz": "121561",
        "sparte": "STROM",
        "pruefidentifikator": "13017",
        "absender": {
          "boTyp": "MARKTTEILNEHMER",
          "versionStruktur": "1",
          "rollencodenummer": "9904446000007",
          "marktrolle": "MSB",
          "rollencodetyp": "BDEW"
        },
        "empfaenger": {
          "boTyp": "MARKTTEILNEHMER",
          "versionStruktur": "1",
          "rollencodenummer": "9900321000005",
          "marktrolle": "NB",
          "rollencodetyp": "BDEW"
        },
        "dokumentennummer": "744163BGM",
        "kategorie": "7",
        "nachrichtenfunktion": "9",
        "nachrichtendatum": "2026-10-01T11:00:00Z",
        "nachrichtenreferenznummer": "744163",
        "typ": "VL"
      },
      "zusatzdaten": {}
    }
  }
]
```

</Beispielnachricht>

*Source: [`2.edi`](https://github.com/conuti-gmbh/maco-edi-testfiles/blob/main/inbound/v202610/mscons/13017/2.edi) · [`2.json`](https://github.com/conuti-gmbh/maco-edi-testfiles/blob/main/outbound/v202610/mscons/13017/2.json)*

<Testdateien edi="/testdaten/202610/mscons/13017/2.edi" json="/testdaten/202610/mscons/13017/2.json" />

</div>

### Example 3

<div data-maco="beispielfall" className="maco-beispielfall">

<Beispielnachricht>

```text title="EDIFACT"
UNA:+.? '
UNB+UNOC:3+9904446000007:500+9900051000002:500+{{date}}:{{time}}+141757++VL'
UNH+137826+MSCONS:D:04B:UN:2.5'
BGM+7+137826BGM+9'
DTM+137:202610011100?+00:303'
RFF+AGI:REF12345678910'
RFF+Z13:13017'
NAD+MS+9904446000007::293'
NAD+MR+9900051000002::293'
UNS+D'
NAD+DP'
LOC+172'
RFF+AGK:34590456ujdfsdghdlktztwqq-053trg'
LIN+1'
PIA+5+1-65?:1.8.0:SRW'
QTY+220:904'
DTM+7:202509302200?+00:303'
UNT+16+137826'
UNZ+1+141757'
```

```json title="BO4E-JSON"
[
  {
    "businessKey": "<businessKey>",
    "processDate": null,
    "dataSource": "OUTBOUND",
    "version": 1,
    "edifactVersion": 202610,
    "data": {
      "stammdaten": {
        "ZAEHLER": [
          {
            "boTyp": "ZAEHLER",
            "versionStruktur": "1",
            "zaehlernummer": "G12345678910",
            "sparte": "STROM"
          }
        ],
        "ENERGIEMENGE": [
          {
            "boTyp": "ENERGIEMENGE",
            "versionStruktur": "1",
            "konfiguration": "34590456ujdfsdghdlktztwqq-053trg",
            "energieverbrauch": [
              {
                "messwertstatus": "ABGELESEN",
                "obiskennzahl": "1-65:1.8.0",
                "wert": 904,
                "nutzungszeitpunkt": "2025-09-30T22:00:00Z",
                "position": 1
              }
            ]
          }
        ]
      },
      "transaktionsdaten": {
        "datenaustauschreferenz": "141757",
        "sparte": "STROM",
        "pruefidentifikator": "13017",
        "absender": {
          "boTyp": "MARKTTEILNEHMER",
          "versionStruktur": "1",
          "marktrolle": "MSB",
          "rollencodenummer": "9904446000007",
          "rollencodetyp": "BDEW"
        },
        "empfaenger": {
          "boTyp": "MARKTTEILNEHMER",
          "versionStruktur": "1",
          "marktrolle": "LF",
          "rollencodenummer": "9900051000002",
          "rollencodetyp": "BDEW"
        },
        "dokumentennummer": "137826BGM",
        "kategorie": "7",
        "nachrichtenfunktion": "9",
        "nachrichtendatum": "2026-10-01T11:00:00Z",
        "nachrichtenreferenznummer": "137826",
        "typ": "VL",
        "anfrageReferenz": "REF12345678910"
      },
      "zusatzdaten": {}
    }
  }
]
```

</Beispielnachricht>

*Source: [`3.edi`](https://github.com/conuti-gmbh/maco-edi-testfiles/blob/main/inbound/v202610/mscons/13017/3.edi) · [`3.json`](https://github.com/conuti-gmbh/maco-edi-testfiles/blob/main/outbound/v202610/mscons/13017/3.json)*

<Testdateien edi="/testdaten/202610/mscons/13017/3.edi" json="/testdaten/202610/mscons/13017/3.json" />

</div>

## Belongs to these role views

The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are **LF**, **NB**, **MSB** and **ÜNB**.

<div className="maco-tabellenrahmen">

| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | [Business data request](/en/prozessdoku/202610/LF/GPKE-Teil4-geschaeftsdatenanfrage) | GPKE part 4 | Electricity | Step 4 |
| LF | LF | [Processing and transmission of values from the MSB of the market location](/en/prozessdoku/202610/LF/WiM-Teil2-aufbereitung-und-uebermittlung-von-werten-vom-msb-der-marktlokation) | WiM electricity part 2 | Electricity | Step 1 |
| LF | LF | [Processing and transmission of values from the MSB of the market location](/en/prozessdoku/202610/LF/WiM-Teil2-aufbereitung-und-uebermittlung-von-werten-vom-msb-der-marktlokation) | WiM electricity part 2 | Electricity | Step 2 |
| LF | LF | [Transmission of meter readings from the LF](/en/prozessdoku/202610/LF/WiM-Teil2-uebermittlung-von-zaehlerstaenden-vom-lf) | WiM electricity part 2 | Electricity | Step 1 |
| NB | NB | [Business data request](/en/prozessdoku/202610/NB/GPKE-Teil4-geschaeftsdatenanfrage) | GPKE part 4 | Electricity | Step 4 |
| NB | NB | [Processing and transmission of values from the MSB of the market location](/en/prozessdoku/202610/NB/WiM-Teil2-aufbereitung-und-uebermittlung-von-werten-vom-msb-der-marktlokation) | WiM electricity part 2 | Electricity | Step 1 |
| NB | NB | [Processing and transmission of values from the MSB of the market location](/en/prozessdoku/202610/NB/WiM-Teil2-aufbereitung-und-uebermittlung-von-werten-vom-msb-der-marktlokation) | WiM electricity part 2 | Electricity | Step 2 |
| NB | NB | [Transmission of meter readings from the NB](/en/prozessdoku/202610/NB/WiM-Teil2-uebermittlung-von-zaehlerstaenden-vom-nb) | WiM electricity part 2 | Electricity | Step 1 |
| MSB | MSB | [Business data request](/en/prozessdoku/202610/MSB/GPKE-Teil4-geschaeftsdatenanfrage) | GPKE part 4 | Electricity | Step 4 |
| MSB | MSB-MALO | [Processing and transmission of values from the MSB of the market location](/en/prozessdoku/202610/MSB/WiM-Teil2-aufbereitung-und-uebermittlung-von-werten-vom-msb-der-marktlokation) | WiM electricity part 2 | Electricity | Step 1 |
| MSB | MSB-MALO | [Processing and transmission of values from the MSB of the market location](/en/prozessdoku/202610/MSB/WiM-Teil2-aufbereitung-und-uebermittlung-von-werten-vom-msb-der-marktlokation) | WiM electricity part 2 | Electricity | Step 2 |
| MSB | MSB-MALO | [Processing and transmission of values from the MSB of the metering location](/en/prozessdoku/202610/MSB--MSB-MALO/WiM-Teil2-aufbereitung-und-uebermittlung-von-werten-vom-msb-der-messlokation) | WiM electricity part 2 | Electricity | Step 1 |
| MSB | MSB-MELO | [Processing and transmission of values from the MSB of the metering location](/en/prozessdoku/202610/MSB--MSB-MELO/WiM-Teil2-aufbereitung-und-uebermittlung-von-werten-vom-msb-der-messlokation) | WiM electricity part 2 | Electricity | Step 1 |
| MSB | MSB-MELO | [Transmission of meter readings from the LF](/en/prozessdoku/202610/MSB/WiM-Teil2-uebermittlung-von-zaehlerstaenden-vom-lf) | WiM electricity part 2 | Electricity | Step 1 |
| MSB | MSB-MELO | [Transmission of meter readings from the NB](/en/prozessdoku/202610/MSB/WiM-Teil2-uebermittlung-von-zaehlerstaenden-vom-nb) | WiM electricity part 2 | Electricity | Step 1 |
| MSB | MSBA | [Device replacement](/en/prozessdoku/202610/MSB--MSBA/WiM-Teil1-geraetewechsel) | WiM electricity part 1 | Electricity | Step 5 |
| MSB | MSBA | [Device takeover](/en/prozessdoku/202610/MSB--MSBA/WiM-Teil1-geraeteuebernahme) | WiM electricity part 1 | Electricity | Step 5 |
| MSB | MSBN | [Device replacement](/en/prozessdoku/202610/MSB--MSBN/WiM-Teil1-geraetewechsel) | WiM electricity part 1 | Electricity | Step 5 |
| MSB | MSBN | [Device takeover](/en/prozessdoku/202610/MSB--MSBN/WiM-Teil1-geraeteuebernahme) | WiM electricity part 1 | Electricity | Step 5 |
| ÜNB | ÜNB | [Processing and transmission of values from the MSB of the market location](/en/prozessdoku/202610/UENB/WiM-Teil2-aufbereitung-und-uebermittlung-von-werten-vom-msb-der-marktlokation) | WiM electricity part 2 | Electricity | Step 1 |
| ÜNB | ÜNB | [Processing and transmission of values from the MSB of the market location](/en/prozessdoku/202610/UENB/WiM-Teil2-aufbereitung-und-uebermittlung-von-werten-vom-msb-der-marktlokation) | WiM electricity part 2 | Electricity | Step 2 |

</div>

## Business classification

<div className="maco-tabellenrahmen">

| Attribute | Value |
|---|---|
| Use case (AHB) | Meter reading (electricity) |
| AHB | MSCONS AHB |
| Transmission channel | MP |

</div>

:::caution{title="This check identifier is used in 11 contexts"}

Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.

:::

<div className="maco-tabellenrahmen">

| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| Processes for the exchange of information between grid operator and the guarantee of origin register (HKN-R) of the Federal Environment Agency (UBA) | Ch. 2.3 No. 5 | NB → RB HKN-R | Response to meter reading values subscription |
| Processes for the exchange of information between grid operator and the guarantee of origin register (HKN-R) of the Federal Environment Agency (UBA) | Ch. 2.4 Case 2 No. 4 | NB → RB HKN-R | Response to meter reading values subscription |
| GPKE part 4 | Business data request | MSB → LF | Response |
| WiM electricity part 1 | Device replacement | MSB (corresponds to MSBN on the object metering location) → MSB (corresponds to MSBA on the object metering location) | Meter reading and point in time of the device removal |
| WiM electricity part 1 | Device takeover | MSB (corresponds to MSBA on the object metering location) → MSB (corresponds to MSBN on the object metering location) | Meter reading for the device takeover |
| WiM electricity part 2 | Processing and transmission of values from the MSB of the metering location | MSB (corresponds to the MSB on the object metering location) → MSB (corresponds to the MSB on the object market location) | Value (metering location) |
| WiM electricity part 2 | Processing and transmission of values from the MSB of the market location | MSB (corresponds to the MSB on the object market location) → NB | Value (market location / metering location) at NB |
| WiM electricity part 2 | Processing and transmission of values from the MSB of the market location | MSB (corresponds to the MSB on the object market location) → LF | Value (market location / metering location) at LF |
| WiM electricity part 2 | Transmission of meter readings from LF | LF → MSB (metering location) | Meter reading (metering location) |
| WiM electricity part 2 | Transmission of meter readings from NB | NB → MSB (metering location) | Meter reading (metering location) |
| GPKE part 4 | Business data request | MSB → NB | Response |

</div>

## Transaction and responses

**Role of this check identifier: response.** Basis: the title or the action of the Prüfi table begins with “response”. The title names **no** polarity — whether this message confirms or rejects is decided by the response code, not by the check identifier.

### Which request this message responds to

<div className="maco-tabellenrahmen">

| Role | Check identifier | Use case | Message type | Origin of supply |
|---|---|---|---|---|
| Request | [17102](/schnittstellen/202610/pruefi/ORDERS/PI_17102) | Request for values | ORDERS | from the step sequence |

</div>

**Forwarding (triangular communication):** The preceding step holds 21010 with the **same** send direction. This message therefore does not answer the sender of the preceding step, it forwards — which is why there is no response sentence here.

### In which field the request is quoted

<div className="maco-tabellenrahmen">

| Reference field of this message | EDIFACT segment | Target field in the request |
|---|---|---|
| `anfrageReferenz` | `SG1.RFF+AGI` | `dokumentennummer` |

</div>

RFF+AGI quotes the `BGM` of the request; the target is its `dokumentennummer`. Measured: 17102 carries `dokumentennummer` in `BGM+[7|Z28|Z48]`.

**Check identifiers of the same AHB table:** No other check identifier of message type MSCONS has the same row structure in this version.

<Hinweisbereich>

An **\*** after a field or group name marks a **mandatory field** or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.

The status column carries two vocabularies because the manual answers two questions: on a **group row**, *Muss*, *Soll* or *Kann* states whether the EDIFACT segment must be present; on a **field row**, *X* states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.

For this check identifier, the application handbook lists **148 rows**. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.

The **Condition** column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.

The test data contains 3 transactions for this check identifier under the message type `mscons`. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.

:::note{title="Placeholder from the test data set"}

The test data set carries placeholders instead of valid values: `{{date}}` and `{{time}}` in the UNB interchange envelope of every EDIFACT file. **The page replaces these on call with the current date and the current time** — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.

`<businessKey>` stays in place. It is not a time value, and an invented key would look like a valid one.

:::

</Hinweisbereich>