# Check identifier 13020 — Curtailed energy transfer time series

<span hidden data-pagefind-meta={"title:Check identifier 13020 — Curtailed energy transfer time series · MSCONS · Format version 202610"} />

Check identifier **13020** · EDIFACT message type **MSCONS** · Format version **202610**

:::info{title="This page is derived from the application handbook"}

The MACO APP does not carry this check identifier. The complete Prüfi pages of this level are produced from the specifications of the application — one class in the templater per check identifier — and that is where the **assignment to the business objects (BO4E)** comes from: which object carries which field of the message.

The catalogue of the application handbook is the larger set. This page therefore shows what the handbook itself provides — use case, process context and the AHB field list with its conditions. A data structure according to BO4E is not shown, and not because there is none, but because the application does not form one for this check identifier.

All check identifiers in this situation — and the corresponding figures — are listed by [the overview of this version](/en/schnittstellen/202610/pruefi/nicht-gefuehrt).

:::

## Application handbook (AHB)

<Handbuchsatz>

<div className="maco-tabellenrahmen" data-maco="ahb-tabelle">

| Structure (EDIFACT) | Description | Format | <span className="hbs-p" title="Ausfallarbeitsüberführungszeitreihe">13020</span> | Condition |
|---|---|---|---|---|
| <span className="hbs-g hbs-e0">**UNB**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`0001 UNOC`</span><span className="hbs-nr">00010</span> | UN/ECE character set C | — | X | — |
| <span className="hbs-f hbs-e1">`0002 3`</span><span className="hbs-nr">00020</span> | Version 3 | — | X | — |
| <span className="hbs-f hbs-e1">`0004`</span><span className="hbs-nr">00030</span> | MP-ID Sender | — | X | — |
| <span className="hbs-f hbs-e1">`0007 14`</span><span className="hbs-nr">00040</span> | GS1 | — | X | — |
| <span className="hbs-f hbs-e1">`0007 500`</span><span className="hbs-nr">00050</span> | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| <span className="hbs-f hbs-e1">`0010`</span><span className="hbs-nr">00060</span> | MP-ID recipient | — | X | — |
| <span className="hbs-f hbs-e1">`0007 14`</span><span className="hbs-nr">00070</span> | GS1 | — | X | — |
| <span className="hbs-f hbs-e1">`0007 500`</span><span className="hbs-nr">00080</span> | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| <span className="hbs-f hbs-e1">`0017`</span><span className="hbs-nr">00090</span> | Date of creation | — | X | — |
| <span className="hbs-f hbs-e1">`0019`</span><span className="hbs-nr">00100</span> | Time of creation | — | X | — |
| <span className="hbs-f hbs-e1">`0020`</span><span className="hbs-nr">00110</span> | Interchange control reference | — | X | <span className="hbs-marke">[918]</span> |
| <span className="hbs-f hbs-e1">`0026 TL`</span><span className="hbs-nr">00120</span> | Load curve, any time period | — | X | — |
| <span className="hbs-f hbs-e1">`0035 1`</span><span className="hbs-nr">00130</span> | Transmission file is a test | — | — | S <span className="hbs-marke">[155]</span> |
| <span className="hbs-g hbs-e0">**UNH**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`0062`</span><span className="hbs-nr">00140</span> | Message reference number | — | X | — |
| <span className="hbs-f hbs-e1">`0065 MSCONS`</span><span className="hbs-nr">00150</span> | Report on the consumption of measurable services | — | X | — |
| <span className="hbs-f hbs-e1">`0052 D`</span><span className="hbs-nr">00160</span> | Draft version | — | X | — |
| <span className="hbs-f hbs-e1">`0054 04B`</span><span className="hbs-nr">00170</span> | Edition 2004 - B | — | X | — |
| <span className="hbs-f hbs-e1">`0051 UN`</span><span className="hbs-nr">00180</span> | UN/CEFACT | — | X | — |
| <span className="hbs-f hbs-e1">`0057 2.5`</span><span className="hbs-nr">00190</span> | Version number of the underlying BDEW message description | — | X | — |
| <span className="hbs-g hbs-e0">**BGM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1001 Z43`</span><span className="hbs-nr">00200</span> | Redispatch Curtailed energy transfer time series | — | X | — |
| <span className="hbs-f hbs-e1">`1001 Z69`</span><span className="hbs-nr">00210</span> | Redispatch daily curtailed energy transfer time series | — | X | — |
| <span className="hbs-f hbs-e1">`1004`</span><span className="hbs-nr">00220</span> | Document number | — | X | — |
| <span className="hbs-f hbs-e1">`1225 9`</span><span className="hbs-nr">00230</span> | Original | — | X | — |
| <span className="hbs-g hbs-e0">**DTM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`2005 137`</span><span className="hbs-nr">00240</span> | Document-/message date/time | — | X | — |
| <span className="hbs-f hbs-e1">`2380`</span><span className="hbs-nr">00250</span> | Date or time or time span, value | — | X | <span className="hbs-marke">[931]</span> <span className="hbs-marke">[494]</span> |
| <span className="hbs-f hbs-e1">`2379 303`</span><span className="hbs-nr">00260</span> | CCYYMMDDHHMMZZZ | — | X | — |
| <span className="hbs-g hbs-e0">**SG1.RFF**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1153 Z13`</span><span className="hbs-nr">00270</span> | Check identifier | — | X | — |
| <span className="hbs-f hbs-e1">`1154 13020`</span><span className="hbs-nr">00280</span> | Redispatch Curtailed energy transfer time series | — | X | — |
| <span className="hbs-g hbs-e0">**SG2.NAD**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3035 MS`</span><span className="hbs-nr">00290</span> | Document-/message sender or sender | — | X | — |
| <span className="hbs-f hbs-e1">`3039`</span><span className="hbs-nr">00300</span> | MP-ID | — | X | <span className="hbs-marke">[117]</span> |
| <span className="hbs-f hbs-e1">`3055 9`</span><span className="hbs-nr">00310</span> | GS1 | — | X | — |
| <span className="hbs-f hbs-e1">`3055 293`</span><span className="hbs-nr">00320</span> | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| <span className="hbs-g hbs-e0">**SG2.NAD**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3035 MR`</span><span className="hbs-nr">00330</span> | Message recipient | — | X | — |
| <span className="hbs-f hbs-e1">`3039`</span><span className="hbs-nr">00340</span> | MP-ID | — | X | <span className="hbs-marke">[117]</span> |
| <span className="hbs-f hbs-e1">`3055 9`</span><span className="hbs-nr">00350</span> | GS1 | — | X | — |
| <span className="hbs-f hbs-e1">`3055 293`</span><span className="hbs-nr">00360</span> | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| <span className="hbs-g hbs-e0">**UNS**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`0081 D`</span><span className="hbs-nr">00370</span> | Separation of header and detail section | — | X | — |
| <span className="hbs-g hbs-e0">**SG5.NAD**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3035 Z15`</span><span className="hbs-nr">00380</span> | Transfer time series | — | X | — |
| <span className="hbs-g hbs-e0">**SG6.LOC**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3227 172`</span><span className="hbs-nr">00390</span> | Reporting point | — | X | — |
| <span className="hbs-f hbs-e1">`3225`</span><span className="hbs-nr">00400</span> | Designation | — | X | <span className="hbs-marke">[951]</span> <span className="hbs-marke">[511]</span> |
| <span className="hbs-g hbs-e0">**SG6.DTM**</span> | — | — | Must | <span className="hbs-marke">[150]</span> |
| <span className="hbs-f hbs-e1">`2005 163`</span><span className="hbs-nr">00410</span> | Processing, start date/time | — | X | — |
| <span className="hbs-f hbs-e1">`2380`</span><span className="hbs-nr">00420</span> | Date or time or time span, value | — | X | <span className="hbs-marke">[931]</span> |
| <span className="hbs-f hbs-e1">`2379 303`</span><span className="hbs-nr">00430</span> | CCYYMMDDHHMMZZZ | — | X | — |
| <span className="hbs-g hbs-e0">**SG6.DTM**</span> | — | — | Must | <span className="hbs-marke">[150]</span> |
| <span className="hbs-f hbs-e1">`2005 164`</span><span className="hbs-nr">00440</span> | Processing, end date/time | — | X | — |
| <span className="hbs-f hbs-e1">`2380`</span><span className="hbs-nr">00450</span> | Date or time or time span, value | — | X | <span className="hbs-marke">[931]</span> |
| <span className="hbs-f hbs-e1">`2379 303`</span><span className="hbs-nr">00460</span> | CCYYMMDDHHMMZZZ | — | X | — |
| <span className="hbs-g hbs-e0">**SG6.DTM**</span> | — | — | Must | <span className="hbs-marke">[121]</span> |
| <span className="hbs-f hbs-e1">`2005 492`</span><span className="hbs-nr">00470</span> | Balancing date, -time, -period | — | X | — |
| <span className="hbs-f hbs-e1">`2380`</span><span className="hbs-nr">00480</span> | Date or time or time span, value | — | X | — |
| <span className="hbs-f hbs-e1">`2379 610`</span><span className="hbs-nr">00490</span> | CCYYMM | — | X | — |
| <span className="hbs-g hbs-e0">**SG6.DTM**</span> | — | — | Must | <span className="hbs-marke">[121]</span> |
| <span className="hbs-f hbs-e1">`2005 293`</span><span className="hbs-nr">00500</span> | Completion date/time | — | X | — |
| <span className="hbs-f hbs-e1">`2380`</span><span className="hbs-nr">00510</span> | Date or time or time span, value | — | X | <span className="hbs-marke">[931]</span> |
| <span className="hbs-f hbs-e1">`2379 304`</span><span className="hbs-nr">00520</span> | CCYYMMDDHHMMSSZZZ | — | X | — |
| <span className="hbs-g hbs-e0">**SG9.LIN**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1082`</span><span className="hbs-nr">00530</span> | Line item number | — | X | <span className="hbs-marke">[908]</span> |
| <span className="hbs-g hbs-e0">**SG9.PIA**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`4347 5`</span><span className="hbs-nr">00540</span> | Product identification | — | X | — |
| <span className="hbs-f hbs-e1">`7140`</span><span className="hbs-nr">00550</span> | Medium / OBIS code number | — | X | <span className="hbs-marke">[501]</span> |
| <span className="hbs-f hbs-e1">`7143 Z08`</span><span className="hbs-nr">00560</span> | Medium | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.QTY**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`6063 79`</span><span className="hbs-nr">00570</span> | Energy quantity totalled (total value, balance total) | — | X | — |
| <span className="hbs-f hbs-e1">`6060`</span><span className="hbs-nr">00580</span> | Quantity | — | X | <span className="hbs-marke">[910]</span> ∧ <span className="hbs-marke">[906]</span> |
| <span className="hbs-f hbs-e1">`6411 KWH`</span><span className="hbs-nr">00590</span> | Kilowatt hour | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.DTM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`2005 163`</span><span className="hbs-nr">00600</span> | Processing, start date/time | — | X | — |
| <span className="hbs-f hbs-e1">`2380`</span><span className="hbs-nr">00610</span> | Date or time or time span, value | — | X | <span className="hbs-marke">[931]</span> <span className="hbs-marke">[495]</span> |
| <span className="hbs-f hbs-e1">`2379 303`</span><span className="hbs-nr">00620</span> | CCYYMMDDHHMMZZZ | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.DTM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`2005 164`</span><span className="hbs-nr">00630</span> | Processing, end date/time | — | X | — |
| <span className="hbs-f hbs-e1">`2380`</span><span className="hbs-nr">00640</span> | Date or time or time span, value | — | X | <span className="hbs-marke">[931]</span> <span className="hbs-marke">[495]</span> |
| <span className="hbs-f hbs-e1">`2379 303`</span><span className="hbs-nr">00650</span> | CCYYMMDDHHMMZZZ | — | X | — |
| <span className="hbs-g hbs-e0">**UNT**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`0074`</span><span className="hbs-nr">00660</span> | Number of segments in a message | — | X | — |
| <span className="hbs-f hbs-e1">`0062`</span><span className="hbs-nr">00670</span> | Message reference number | — | X | — |
| <span className="hbs-g hbs-e0">**UNZ**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`0036`</span><span className="hbs-nr">00680</span> | Interchange counter | — | X | — |
| <span className="hbs-f hbs-e1">`0020`</span><span className="hbs-nr">00690</span> | Interchange control reference | — | X | — |

</div>

</Handbuchsatz>

### Conditions of this table

The free text of the 14 conditions referenced by the rows above. All conditions of the message type are listed in the [condition index MSCONS](/en/referenz/202610/ahb-bedingungen/MSCONS).

<div className="maco-tabellenrahmen">

| Marker | Condition |
|---|---|
| **[117]** | Only MP-ID from the electricity division |
| **[121]** | if BGM+Z43 (Redispatch outage energy transfer time series) is present |
| **[150]** | If BGM+Z69 (Redispatch daily curtailed energy transfer time series) present. |
| **[155]** | If the transmission file is exchanged for test purposes. |
| **[494]** | The date stated here must be the point in time at which the document was created, or a point in time before that. |
| **[495]** | The point in time must be ≤ the value in DE2380 of DTM+137 |
| **[501]** | Note: Only the values that are marked with the corresponding check identifier in the EDI@Energy code list of the OBIS codes and media are permitted. |
| **[511]** | Note: Use of the ID of the MaBiS-ZP |
| **[906]** | Format: max. 3 decimal places |
| **[908]** | Format: possible values: 1 to n |
| **[910]** | Format: Possible value: &lt; 0 or ≥ 0 |
| **[918]** | Format: Characters from the character set defined via UNOC, where only capital letters are permitted among the letters. |
| **[931]** | Format: ZZZ = +00 |
| **[951]** | Format: Metering point identifier |

</div>

## Belongs to these role views

The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are **NB**, **ÜNB**, **BIKO** and **BKV**.

<div className="maco-tabellenrahmen">

| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| NB | ANB | [Transfer of curtailed energy from the EEG-BK of the NB to the ÜNB](/en/prozessdoku/202610/NB/MaBiS-ueberfuehrung-der-ausfallarbeit-aus-dem-eeg-bk-des-nb-an-den-uenb) | MaBiS | Electricity | Step 1 |
| NB | ANB | [Transfer of curtailed energy from the EEG-BK of the NB to the ÜNB](/en/prozessdoku/202610/NB/MaBiS-ueberfuehrung-der-ausfallarbeit-aus-dem-eeg-bk-des-nb-an-den-uenb) | MaBiS | Electricity | Step 2 |
| NB | ANB | [Transfer of curtailed energy from the EEG-BK of the NB to the ÜNB](/en/prozessdoku/202610/NB/MaBiS-ueberfuehrung-der-ausfallarbeit-aus-dem-eeg-bk-des-nb-an-den-uenb) | MaBiS | Electricity | Step 3 |
| NB | ANB | [Transfer of curtailed energy from the EEG-BK of the NB to the ÜNB](/en/prozessdoku/202610/NB/MaBiS-ueberfuehrung-der-ausfallarbeit-aus-dem-eeg-bk-des-nb-an-den-uenb) | MaBiS | Electricity | Step 4 |
| NB | ANB | [Transmission of the monthly curtailed energy transfer time series (AAÜZ)](/en/prozessdoku/202610/NB--ANB/MaBiS-uebermittlung-der-monatlichen-ausfallarbeitsueberfuehrungszeitreihe-aauez) | MaBiS | Electricity | Step 1 |
| NB | ANB | [Transmission of the monthly curtailed energy transfer time series (AAÜZ)](/en/prozessdoku/202610/NB--ANB/MaBiS-uebermittlung-der-monatlichen-ausfallarbeitsueberfuehrungszeitreihe-aauez) | MaBiS | Electricity | Step 3 |
| NB | ANB | [Transmission of the monthly curtailed energy transfer time series between ANB and BKV (anfNB)](/en/prozessdoku/202610/NB/MaBiS-uebermittlung-der-monatlichen-ausfallarbeitsueberfuehrungszeitreihe-zwischen-anb-und-bkv-anfnb) | MaBiS | Electricity | Step 1 |
| NB | ANB | [Transmission of the monthly curtailed energy transfer time series between ANB and BKV (anfNB)](/en/prozessdoku/202610/NB/MaBiS-uebermittlung-der-monatlichen-ausfallarbeitsueberfuehrungszeitreihe-zwischen-anb-und-bkv-anfnb) | MaBiS | Electricity | Step 3 |
| NB | ANB | [Transmission of the daily curtailed energy transfer time series (AAÜZ)](/en/prozessdoku/202610/NB/MaBiS-uebermittlung-der-taeglichen-ausfallarbeitsueberfuehrungszeitreihe-aauez) | MaBiS | Electricity | Step 1 |
| NB | NB | [Transmission of the monthly curtailed energy transfer time series (AAÜZ)](/en/prozessdoku/202610/NB/MaBiS-uebermittlung-der-monatlichen-ausfallarbeitsueberfuehrungszeitreihe-aauez) | MaBiS | Electricity | Step 1 |
| NB | NB | [Transmission of the monthly curtailed energy transfer time series (AAÜZ)](/en/prozessdoku/202610/NB/MaBiS-uebermittlung-der-monatlichen-ausfallarbeitsueberfuehrungszeitreihe-aauez) | MaBiS | Electricity | Step 3 |
| ÜNB | ÜNB | [Transfer of curtailed energy from the EEG-BK of the NB to the ÜNB](/en/prozessdoku/202610/UENB/MaBiS-ueberfuehrung-der-ausfallarbeit-aus-dem-eeg-bk-des-nb-an-den-uenb) | MaBiS | Electricity | Step 1 |
| ÜNB | ÜNB | [Transfer of curtailed energy from the EEG-BK of the NB to the ÜNB](/en/prozessdoku/202610/UENB/MaBiS-ueberfuehrung-der-ausfallarbeit-aus-dem-eeg-bk-des-nb-an-den-uenb) | MaBiS | Electricity | Step 2 |
| ÜNB | ÜNB | [Transfer of curtailed energy from the EEG-BK of the NB to the ÜNB](/en/prozessdoku/202610/UENB/MaBiS-ueberfuehrung-der-ausfallarbeit-aus-dem-eeg-bk-des-nb-an-den-uenb) | MaBiS | Electricity | Step 3 |
| ÜNB | ÜNB | [Transfer of curtailed energy from the EEG-BK of the NB to the ÜNB](/en/prozessdoku/202610/UENB/MaBiS-ueberfuehrung-der-ausfallarbeit-aus-dem-eeg-bk-des-nb-an-den-uenb) | MaBiS | Electricity | Step 4 |
| ÜNB | ÜNB | [Transmission of the daily curtailed energy transfer time series (AAÜZ)](/en/prozessdoku/202610/UENB/MaBiS-uebermittlung-der-taeglichen-ausfallarbeitsueberfuehrungszeitreihe-aauez) | MaBiS | Electricity | Step 1 |
| BIKO | BIKO | [Transfer of curtailed energy from the EEG-BK of the NB to the ÜNB](/en/prozessdoku/202610/BIKO/MaBiS-ueberfuehrung-der-ausfallarbeit-aus-dem-eeg-bk-des-nb-an-den-uenb) | MaBiS | Electricity | Step 1 |
| BIKO | BIKO | [Transfer of curtailed energy from the EEG-BK of the NB to the ÜNB](/en/prozessdoku/202610/BIKO/MaBiS-ueberfuehrung-der-ausfallarbeit-aus-dem-eeg-bk-des-nb-an-den-uenb) | MaBiS | Electricity | Step 2 |
| BIKO | BIKO | [Transfer of curtailed energy from the EEG-BK of the NB to the ÜNB](/en/prozessdoku/202610/BIKO/MaBiS-ueberfuehrung-der-ausfallarbeit-aus-dem-eeg-bk-des-nb-an-den-uenb) | MaBiS | Electricity | Step 3 |
| BIKO | BIKO | [Transfer of curtailed energy from the EEG-BK of the NB to the ÜNB](/en/prozessdoku/202610/BIKO/MaBiS-ueberfuehrung-der-ausfallarbeit-aus-dem-eeg-bk-des-nb-an-den-uenb) | MaBiS | Electricity | Step 4 |
| BIKO | BIKO | [Transmission of the monthly curtailed energy transfer time series (AAÜZ)](/en/prozessdoku/202610/BIKO/MaBiS-uebermittlung-der-monatlichen-ausfallarbeitsueberfuehrungszeitreihe-aauez) | MaBiS | Electricity | Step 1 |
| BIKO | BIKO | [Transmission of the monthly curtailed energy transfer time series (AAÜZ)](/en/prozessdoku/202610/BIKO/MaBiS-uebermittlung-der-monatlichen-ausfallarbeitsueberfuehrungszeitreihe-aauez) | MaBiS | Electricity | Step 3 |
| BIKO | BIKO | [Transmission of the monthly curtailed energy transfer time series between ANB and BKV (anfNB)](/en/prozessdoku/202610/BIKO/MaBiS-uebermittlung-der-monatlichen-ausfallarbeitsueberfuehrungszeitreihe-zwischen-anb-und-bkv-anfnb) | MaBiS | Electricity | Step 1 |
| BIKO | BIKO | [Transmission of the monthly curtailed energy transfer time series between ANB and BKV (anfNB)](/en/prozessdoku/202610/BIKO/MaBiS-uebermittlung-der-monatlichen-ausfallarbeitsueberfuehrungszeitreihe-zwischen-anb-und-bkv-anfnb) | MaBiS | Electricity | Step 3 |
| BKV | BKV-ANFNB | [Transmission of the monthly curtailed energy transfer time series between ANB and BKV (anfNB)](/en/prozessdoku/202610/BKV/MaBiS-uebermittlung-der-monatlichen-ausfallarbeitsueberfuehrungszeitreihe-zwischen-anb-und-bkv-anfnb) | MaBiS | Electricity | Step 1 |
| BKV | BKV-ANFNB | [Transmission of the monthly curtailed energy transfer time series between ANB and BKV (anfNB)](/en/prozessdoku/202610/BKV/MaBiS-uebermittlung-der-monatlichen-ausfallarbeitsueberfuehrungszeitreihe-zwischen-anb-und-bkv-anfnb) | MaBiS | Electricity | Step 3 |
| BKV | BKV-LF | [Transmission of the monthly curtailed energy transfer time series (AAÜZ)](/en/prozessdoku/202610/BKV/MaBiS-uebermittlung-der-monatlichen-ausfallarbeitsueberfuehrungszeitreihe-aauez) | MaBiS | Electricity | Step 1 |
| BKV | BKV-LF | [Transmission of the monthly curtailed energy transfer time series (AAÜZ)](/en/prozessdoku/202610/BKV/MaBiS-uebermittlung-der-monatlichen-ausfallarbeitsueberfuehrungszeitreihe-aauez) | MaBiS | Electricity | Step 3 |
| BKV | BKV-NB | [Transfer of curtailed energy from the EEG-BK of the NB to the ÜNB](/en/prozessdoku/202610/BKV--BKV-NB/MaBiS-ueberfuehrung-der-ausfallarbeit-aus-dem-eeg-bk-des-nb-an-den-uenb) | MaBiS | Electricity | Step 1 |
| BKV | BKV-NB | [Transfer of curtailed energy from the EEG-BK of the NB to the ÜNB](/en/prozessdoku/202610/BKV--BKV-NB/MaBiS-ueberfuehrung-der-ausfallarbeit-aus-dem-eeg-bk-des-nb-an-den-uenb) | MaBiS | Electricity | Step 2 |
| BKV | BKV-NB | [Transfer of curtailed energy from the EEG-BK of the NB to the ÜNB](/en/prozessdoku/202610/BKV--BKV-NB/MaBiS-ueberfuehrung-der-ausfallarbeit-aus-dem-eeg-bk-des-nb-an-den-uenb) | MaBiS | Electricity | Step 3 |
| BKV | BKV-NB | [Transfer of curtailed energy from the EEG-BK of the NB to the ÜNB](/en/prozessdoku/202610/BKV--BKV-NB/MaBiS-ueberfuehrung-der-ausfallarbeit-aus-dem-eeg-bk-des-nb-an-den-uenb) | MaBiS | Electricity | Step 4 |
| BKV | BKV-UENB | [Transfer of curtailed energy from the EEG-BK of the NB to the ÜNB](/en/prozessdoku/202610/BKV--BKV-UENB/MaBiS-ueberfuehrung-der-ausfallarbeit-aus-dem-eeg-bk-des-nb-an-den-uenb) | MaBiS | Electricity | Step 1 |
| BKV | BKV-UENB | [Transfer of curtailed energy from the EEG-BK of the NB to the ÜNB](/en/prozessdoku/202610/BKV--BKV-UENB/MaBiS-ueberfuehrung-der-ausfallarbeit-aus-dem-eeg-bk-des-nb-an-den-uenb) | MaBiS | Electricity | Step 2 |
| BKV | BKV-UENB | [Transfer of curtailed energy from the EEG-BK of the NB to the ÜNB](/en/prozessdoku/202610/BKV--BKV-UENB/MaBiS-ueberfuehrung-der-ausfallarbeit-aus-dem-eeg-bk-des-nb-an-den-uenb) | MaBiS | Electricity | Step 3 |
| BKV | BKV-UENB | [Transfer of curtailed energy from the EEG-BK of the NB to the ÜNB](/en/prozessdoku/202610/BKV--BKV-UENB/MaBiS-ueberfuehrung-der-ausfallarbeit-aus-dem-eeg-bk-des-nb-an-den-uenb) | MaBiS | Electricity | Step 4 |

</div>

## Business classification

<div className="maco-tabellenrahmen">

| Attribute | Value |
|---|---|
| Use case (AHB) | Curtailed energy transfer time series |
| AHB | MSCONS AHB |
| Transmission channel | AS4 |

</div>

:::caution{title="This check identifier is used in 9 contexts"}

Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.

:::

<div className="maco-tabellenrahmen">

| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| MaBiS | Transmission of the daily curtailed energy transfer time series (AAÜZ) | NB (ANB) → ÜNB | Daily AAÜZ |
| MaBiS | Transmission of the monthly curtailed energy transfer time series (AAÜZ) | NB (ANB) → BIKO | Monthly AAÜZ |
| MaBiS | Transmission of the monthly curtailed energy transfer time series (AAÜZ) | BIKO → BKV (LF) | Forwarding of the monthly AAÜZ |
| MaBiS | Transmission of the monthly curtailed energy transfer time series between ANB and BKV (anfNB) | NB (ANB) → BIKO | Monthly AAÜZ |
| MaBiS | Transmission of the monthly curtailed energy transfer time series between ANB and BKV (anfNB) | BIKO → BKV (of the anfNB) | Forwarding of the monthly AAÜZ |
| MaBiS | Transfer of the curtailed energy from the EEG-BK of the NB to the ÜNB | ÜNB → BIKO | Curtailed energy transfer time series |
| MaBiS | Transfer of the curtailed energy from the EEG-BK of the NB to the ÜNB | BIKO → BKV (ÜNB) | Forwarding of the transfer time series |
| MaBiS | Transfer of the curtailed energy from the EEG-BK of the NB to the ÜNB | BIKO → BKV (NB) | Forwarding of the transfer time series |
| MaBiS | Transfer of the curtailed energy from the EEG-BK of the NB to the ÜNB | BIKO → NB (ANB) | Forwarding of the transfer time series |

</div>

<Hinweisbereich>

The status column carries two vocabularies because the manual answers two questions: on a **group row**, *Muss*, *Soll* or *Kann* states whether the EDIFACT segment must be present; on a **field row**, *X* states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.

For this check identifier, the application handbook lists **90 rows**. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.

The **Condition** column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.

</Hinweisbereich>