# Check identifier 13028 — Basis for POG determination

<span hidden data-pagefind-meta={"title:Check identifier 13028 — Basis for POG determination · MSCONS · Format version 202610"} />

Check identifier **13028** · EDIFACT message type **MSCONS** · Format version **202610**

## Data structure

<Handbuchsatz>

<div className="maco-tabellenrahmen">

| Structure (BO4E) | Description | Format | <span className="hbs-p" title="Grundlage POG-Ermittlung">13028</span> | Condition |
|---|---|---|---|---|
| <span className="hbs-g hbs-e0">**stammdaten** <span className="hbs-pflicht">\*</span></span> | — | object | Must | — |
| <span className="hbs-g hbs-e1">**ENERGIEMENGE** <span className="hbs-liste">[ ]</span> <span className="hbs-pflicht">\*</span></span> | — | object[] | Must | — |
| <span className="hbs-f hbs-e2">[konfiguration](/en/bo4e/202610/bo/Energiemenge#konfiguration)</span> <AhbTabelle pruefid="13028" format="MSCONS" fv="202610" zeile={47} segment="SG5.NAD+DP.SG6.LOC+172" /><span className="hbs-nr">00010</span> | konfiguration | string | X | — |
| <span className="hbs-f hbs-e2">[lokationsId](/en/bo4e/202610/bo/Energiemenge#lokationsid) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13028" format="MSCONS" fv="202610" zeile={47} segment="SG5.NAD+DP.SG6.LOC+172" /><span className="hbs-nr">00020</span> | Unique number of the market location or of the metering location to which the energy quantity belongs | string | X | — |
| <span className="hbs-g hbs-e2">**energieverbrauch** <span className="hbs-liste">[ ]</span> <span className="hbs-pflicht">\*</span></span> | — | object[] | Must | — |
| <span className="hbs-f hbs-e3">[enddatum](/en/bo4e/202610/com/Verbrauch#enddatum) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13028" format="MSCONS" fv="202610" zeile={63} segment="SG5.NAD+DP.SG6.LOC+172.SG9.LIN.SG10.QTY.DTM+164" /><span className="hbs-nr">00030</span> | enddatum | string (date-time) | X | — |
| <span className="hbs-f hbs-e3">[messwertstatus](/en/bo4e/202610/com/Verbrauch#messwertstatus) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13028" format="MSCONS" fv="202610" zeile={55} segment="SG5.NAD+DP.SG6.LOC+172.SG9.LIN.SG10.QTY" /><span className="hbs-nr">00040</span> | The status of a meter reading | [Enum Messwertstatus](/en/bo4e/202610/enum/Messwertstatus) | Must | — |
| <span className="hbs-w hbs-e4">`ABGELESEN`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`ERSATZWERT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`VORSCHLAGSWERT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`NICHT_VERWENDBAR`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`PROGNOSEWERT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`ENERGIEMENGESUMMIERT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`VOLAEUFIGERWERT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`FEHLT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`ANGABE_FUER_LIEFERSCHEIN`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`GRUNDLAGE_POG_ERMITTLUNG`</span> | — | — | Must | — |
| <span className="hbs-f hbs-e3">[obiskennzahl](/en/bo4e/202610/com/Verbrauch#obiskennzahl) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13028" format="MSCONS" fv="202610" zeile={52} segment="SG5.NAD+DP.SG6.LOC+172.SG9.LIN.PIA+5" /><span className="hbs-nr">00050</span> | obiskennzahl | string | X | — |
| <span className="hbs-f hbs-e3">[position](/en/bo4e/202610/com/Verbrauch#position) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13028" format="MSCONS" fv="202610" zeile={49} segment="SG5.NAD+DP.SG6.LOC+172.SG9.LIN" /><span className="hbs-nr">00060</span> | position | integer | Must | — |
| <span className="hbs-f hbs-e3">[startdatum](/en/bo4e/202610/com/Verbrauch#startdatum) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13028" format="MSCONS" fv="202610" zeile={59} segment="SG5.NAD+DP.SG6.LOC+172.SG9.LIN.SG10.QTY.DTM+163" /><span className="hbs-nr">00070</span> | startdatum | string (date-time) | X | — |
| <span className="hbs-f hbs-e3">[wert](/en/bo4e/202610/com/Verbrauch#wert) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13028" format="MSCONS" fv="202610" zeile={55} segment="SG5.NAD+DP.SG6.LOC+172.SG9.LIN.SG10.QTY" /><span className="hbs-nr">00080</span> | wert | number (float) | Must | — |
| <span className="hbs-g hbs-e0">**transaktionsdaten** <span className="hbs-pflicht">\*</span></span> | — | object | Must | — |
| <span className="hbs-f hbs-e1">[dokumentennummer](/en/bo4e/202610/cdoc/Transaktionsdaten#dokumentennummer) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13028" format="MSCONS" fv="202610" zeile={22} segment="BGM+Z85" /><span className="hbs-nr">00090</span> | EDIFACT reference from the BGM segment / BGM | string | X | — |
| <span className="hbs-f hbs-e1">[kategorie](/en/bo4e/202610/cdoc/Transaktionsdaten#kategorie) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13028" format="MSCONS" fv="202610" zeile={22} segment="BGM+Z85" /><span className="hbs-nr">00100</span> | Qualifier from the beginning of the EDIFACT message / BGM | string | X | — |
| <span className="hbs-f hbs-e1">[nachrichtendatum](/en/bo4e/202610/cdoc/Transaktionsdaten#nachrichtendatum) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13028" format="MSCONS" fv="202610" zeile={26} segment="DTM+137" /><span className="hbs-nr">00110</span> | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| <span className="hbs-f hbs-e1">[nachrichtenfunktion](/en/bo4e/202610/cdoc/Transaktionsdaten#nachrichtenfunktion) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13028" format="MSCONS" fv="202610" zeile={22} segment="BGM+Z85" /><span className="hbs-nr">00120</span> | Message function code / BGM | string | X | — |
| <span className="hbs-f hbs-e1">[nachrichtenreferenznummer](/en/bo4e/202610/cdoc/Transaktionsdaten#nachrichtenreferenznummer) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13028" format="MSCONS" fv="202610" zeile={14} segment="UNH" /><span className="hbs-nr">00130</span> | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| <span className="hbs-f hbs-e1">[pruefidentifikator](/en/bo4e/202610/cdoc/Transaktionsdaten#pruefidentifikator) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13028" format="MSCONS" fv="202610" zeile={30} segment="SG1.RFF+Z13" /><span className="hbs-nr">00140</span> | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| <span className="hbs-g hbs-e1">**absender** <span className="hbs-pflicht">\*</span></span> | — | object | Must | — |
| <span className="hbs-f hbs-e2">[rollencodenummer](/en/bo4e/202610/bo/Marktteilnehmer#rollencodenummer) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13028" format="MSCONS" fv="202610" zeile={33} segment="SG2.NAD+MS" /><span className="hbs-nr">00150</span> | Specifies the code value of the market role. | string | X | — |
| <span className="hbs-f hbs-e2">[rollencodetyp](/en/bo4e/202610/bo/Marktteilnehmer#rollencodetyp) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13028" format="MSCONS" fv="202610" zeile={33} segment="SG2.NAD+MS" /><span className="hbs-nr">00160</span> | Indicates the type of the code. | [Enum Rollencodetyp](/en/bo4e/202610/enum/Rollencodetyp) | X | — |
| <span className="hbs-w hbs-e3">`BDEW`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`GS1`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`GLN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`DVGW`</span> | — | — | X | — |
| <span className="hbs-g hbs-e1">**empfaenger** <span className="hbs-pflicht">\*</span></span> | — | object | Must | — |
| <span className="hbs-f hbs-e2">[rollencodenummer](/en/bo4e/202610/bo/Marktteilnehmer#rollencodenummer) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13028" format="MSCONS" fv="202610" zeile={38} segment="SG2.NAD+MR" /><span className="hbs-nr">00170</span> | Specifies the code value of the market role. | string | X | — |
| <span className="hbs-f hbs-e2">[rollencodetyp](/en/bo4e/202610/bo/Marktteilnehmer#rollencodetyp) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="13028" format="MSCONS" fv="202610" zeile={38} segment="SG2.NAD+MR" /><span className="hbs-nr">00180</span> | Indicates the type of the code. | [Enum Rollencodetyp](/en/bo4e/202610/enum/Rollencodetyp) | X | — |
| <span className="hbs-w hbs-e3">`BDEW`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`GS1`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`GLN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`DVGW`</span> | — | — | X | — |

</div>

</Handbuchsatz>

## Application handbook (AHB)

<Handbuchsatz>

<div className="maco-tabellenrahmen" data-maco="ahb-tabelle">

| Structure (EDIFACT) | Description | Format | <span className="hbs-p" title="Grundlage POG-Ermittlung">13028</span> | Condition |
|---|---|---|---|---|
| <span className="hbs-g hbs-e0">**UNB**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`0001 UNOC`</span><span className="hbs-nr">00010</span> | UN/ECE character set C | — | X | — |
| <span className="hbs-f hbs-e1">`0002 3`</span><span className="hbs-nr">00020</span> | Version 3 | — | X | — |
| <span className="hbs-f hbs-e1">`0004`</span><span className="hbs-nr">00030</span> | MP-ID Sender | — | X | — |
| <span className="hbs-f hbs-e1">`0007 14`</span><span className="hbs-nr">00040</span> | GS1 | — | X | — |
| <span className="hbs-f hbs-e1">`0007 500`</span><span className="hbs-nr">00050</span> | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| <span className="hbs-f hbs-e1">`0010`</span><span className="hbs-nr">00060</span> | MP-ID recipient | — | X | — |
| <span className="hbs-f hbs-e1">`0007 14`</span><span className="hbs-nr">00070</span> | GS1 | — | X | — |
| <span className="hbs-f hbs-e1">`0007 500`</span><span className="hbs-nr">00080</span> | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| <span className="hbs-f hbs-e1">`0017`</span><span className="hbs-nr">00090</span> | Date of creation | — | X | — |
| <span className="hbs-f hbs-e1">`0019`</span><span className="hbs-nr">00100</span> | Time of creation | — | X | — |
| <span className="hbs-f hbs-e1">`0020`</span><span className="hbs-nr">00110</span> | Interchange control reference | — | X | <span className="hbs-marke">[918]</span> |
| <span className="hbs-f hbs-e1">`0026 EM`</span><span className="hbs-nr">00120</span> | Energy quantity | — | X | — |
| <span className="hbs-f hbs-e1">`0035 1`</span><span className="hbs-nr">00130</span> | Transmission file is a test | — | — | S <span className="hbs-marke">[155]</span> |
| <span className="hbs-g hbs-e0">**UNH**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`0062`</span><span className="hbs-nr">00140</span> | Message reference number | — | X | — |
| <span className="hbs-f hbs-e1">`0065 MSCONS`</span><span className="hbs-nr">00150</span> | Report on the consumption of measurable services | — | X | — |
| <span className="hbs-f hbs-e1">`0052 D`</span><span className="hbs-nr">00160</span> | Draft version | — | X | — |
| <span className="hbs-f hbs-e1">`0054 04B`</span><span className="hbs-nr">00170</span> | Edition 2004 - B | — | X | — |
| <span className="hbs-f hbs-e1">`0051 UN`</span><span className="hbs-nr">00180</span> | UN/CEFACT | — | X | — |
| <span className="hbs-f hbs-e1">`0057 2.5`</span><span className="hbs-nr">00190</span> | Version number of the underlying BDEW message description | — | X | — |
| <span className="hbs-g hbs-e0">**BGM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1001 Z85`</span><span className="hbs-nr">00200</span> | Basis for POG determination | — | X | — |
| <span className="hbs-f hbs-e1">`1004`</span><span className="hbs-nr">00210</span> | Document number | — | X | — |
| <span className="hbs-f hbs-e1">`1225 9`</span><span className="hbs-nr">00220</span> | Original | — | X | — |
| <span className="hbs-g hbs-e0">**DTM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`2005 137`</span><span className="hbs-nr">00230</span> | Document-/message date/time | — | X | — |
| <span className="hbs-f hbs-e1">`2380`</span><span className="hbs-nr">00240</span> | Date or time or time span, value | — | X | <span className="hbs-marke">[931]</span> <span className="hbs-marke">[494]</span> |
| <span className="hbs-f hbs-e1">`2379 303`</span><span className="hbs-nr">00250</span> | CCYYMMDDHHMMZZZ | — | X | — |
| <span className="hbs-g hbs-e0">**SG1.RFF**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1153 Z13`</span><span className="hbs-nr">00260</span> | Check identifier | — | X | — |
| <span className="hbs-f hbs-e1">`1154 13028`</span><span className="hbs-nr">00270</span> | Basis for POG determination | — | X | — |
| <span className="hbs-g hbs-e0">**SG2.NAD**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3035 MS`</span><span className="hbs-nr">00280</span> | Document-/message sender or sender | — | X | — |
| <span className="hbs-f hbs-e1">`3039`</span><span className="hbs-nr">00290</span> | MP-ID | — | X | <span className="hbs-marke">[117]</span> |
| <span className="hbs-f hbs-e1">`3055 9`</span><span className="hbs-nr">00300</span> | GS1 | — | X | — |
| <span className="hbs-f hbs-e1">`3055 293`</span><span className="hbs-nr">00310</span> | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| <span className="hbs-g hbs-e0">**SG2.NAD**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3035 MR`</span><span className="hbs-nr">00320</span> | Message recipient | — | X | — |
| <span className="hbs-f hbs-e1">`3039`</span><span className="hbs-nr">00330</span> | MP-ID | — | X | <span className="hbs-marke">[117]</span> |
| <span className="hbs-f hbs-e1">`3055 9`</span><span className="hbs-nr">00340</span> | GS1 | — | X | — |
| <span className="hbs-f hbs-e1">`3055 293`</span><span className="hbs-nr">00350</span> | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| <span className="hbs-g hbs-e0">**UNS**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`0081 D`</span><span className="hbs-nr">00360</span> | Separation of header and detail section | — | X | — |
| <span className="hbs-g hbs-e0">**SG5.NAD**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3035 DP`</span><span className="hbs-nr">00370</span> | Supply address | — | X | — |
| <span className="hbs-g hbs-e0">**SG6.LOC**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3227 172`</span><span className="hbs-nr">00380</span> | Reporting point | — | X | — |
| <span className="hbs-f hbs-e1">`3225`</span><span className="hbs-nr">00390</span> | Designation | — | X | <span className="hbs-marke">[950]</span> <span className="hbs-marke">[514]</span> |
| <span className="hbs-g hbs-e0">**SG9.LIN**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1082`</span><span className="hbs-nr">00400</span> | Line item number | — | X | <span className="hbs-marke">[908]</span> |
| <span className="hbs-g hbs-e0">**SG9.PIA**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`4347 5`</span><span className="hbs-nr">00410</span> | Product identification | — | X | — |
| <span className="hbs-f hbs-e1">`7140`</span><span className="hbs-nr">00420</span> | Medium / OBIS code number | — | X | <span className="hbs-marke">[501]</span> |
| <span className="hbs-f hbs-e1">`7143 SRW`</span><span className="hbs-nr">00430</span> | OBIS code | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.QTY**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`6063 Z47`</span><span className="hbs-nr">00440</span> | Basis for POG determination | — | X | — |
| <span className="hbs-f hbs-e1">`6060`</span><span className="hbs-nr">00450</span> | Quantity | — | X | <span className="hbs-marke">[902]</span> ∧ <span className="hbs-marke">[906]</span> |
| <span className="hbs-g hbs-e0">**SG10.DTM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`2005 163`</span><span className="hbs-nr">00460</span> | Processing, start date/time | — | X | — |
| <span className="hbs-f hbs-e1">`2380`</span><span className="hbs-nr">00470</span> | Date or time or time span, value | — | X | <span className="hbs-marke">[UB1]</span> ∧ <span className="hbs-marke">[495]</span> |
| <span className="hbs-f hbs-e1">`2379 303`</span><span className="hbs-nr">00480</span> | CCYYMMDDHHMMZZZ | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.DTM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`2005 164`</span><span className="hbs-nr">00490</span> | Processing, end date/time | — | X | — |
| <span className="hbs-f hbs-e1">`2380`</span><span className="hbs-nr">00500</span> | Date or time or time span, value | — | X | <span className="hbs-marke">[UB1]</span> ∧ <span className="hbs-marke">[495]</span> |
| <span className="hbs-f hbs-e1">`2379 303`</span><span className="hbs-nr">00510</span> | CCYYMMDDHHMMZZZ | — | X | — |
| <span className="hbs-g hbs-e0">**UNT**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`0074`</span><span className="hbs-nr">00520</span> | Number of segments in a message | — | X | — |
| <span className="hbs-f hbs-e1">`0062`</span><span className="hbs-nr">00530</span> | Message reference number | — | X | — |
| <span className="hbs-g hbs-e0">**UNZ**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`0036`</span><span className="hbs-nr">00540</span> | Interchange counter | — | X | — |
| <span className="hbs-f hbs-e1">`0020`</span><span className="hbs-nr">00550</span> | Interchange control reference | — | X | — |

</div>

</Handbuchsatz>

### Conditions of this table

The free text of the 13 conditions referenced by the rows above. All conditions of the message type are listed in the [condition index MSCONS](/en/referenz/202610/ahb-bedingungen/MSCONS).

<div className="maco-tabellenrahmen">

| Marker | Condition |
|---|---|
| **[117]** | Only MP-ID from the electricity division |
| **[155]** | If the transmission file is exchanged for test purposes. |
| **[494]** | The date stated here must be the point in time at which the document was created, or a point in time before that. |
| **[495]** | The point in time must be ≤ the value in DE2380 of DTM+137 |
| **[501]** | Note: Only the values that are marked with the corresponding check identifier in the EDI@Energy code list of the OBIS codes and media are permitted. |
| **[514]** | Note: Use of the ID of the market location |
| **[902]** | Format: Possible value: ≥ 0 |
| **[906]** | Format: max. 3 decimal places |
| **[908]** | Format: possible values: 1 to n |
| **[918]** | Format: Characters from the character set defined via UNOC, where only capital letters are permitted among the letters. |
| **[931]** | Format: ZZZ = +00 |
| **[950]** | Format: market location ID |
| **[UB1]** | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |

</div>

## Example message

<div data-maco="beispielfall" className="maco-beispielfall">

<Beispielnachricht>

```text title="EDIFACT"
UNA:+.? '
UNB+UNOC:3+9900321000005:500+9904446000007:500+{{date}}:{{time}}+161201++EM'
UNH+726947+MSCONS:D:04B:UN:2.5'
BGM+Z85+726947BGM+9'
DTM+137:202610011100?+00:303'
RFF+Z13:13028'
NAD+MS+9900321000005::293'
NAD+MR+9904446000007::293'
UNS+D'
NAD+DP'
LOC+172+50074561188'
LIN+1'
PIA+5+1-1?:1.9.0:SRW'
QTY+Z47:500'
DTM+163:202504012200?+00:303'
DTM+164:202504022200?+00:303'
QTY+Z47:750'
DTM+163:202504152200?+00:303'
DTM+164:202504162200?+00:303'
LIN+2'
PIA+5+1-1?:1.9.0:SRW'
QTY+Z47:1000.123'
DTM+163:202504302200?+00:303'
DTM+164:202505012200?+00:303'
UNT+23+726947'
UNZ+1+161201'
```

```json title="BO4E-JSON"
[
  {
    "businessKey": "<businessKey>",
    "processDate": null,
    "dataSource": "OUTBOUND",
    "version": 1,
    "edifactVersion": 202610,
    "data": {
      "stammdaten": {
        "ENERGIEMENGE": [
          {
            "boTyp": "ENERGIEMENGE",
            "versionStruktur": "1",
            "lokationsId": "50074561188",
            "lokationsTyp": "MALO",
            "energieverbrauch": [
              {
                "startdatum": "2025-04-01T22:00:00Z",
                "enddatum": "2025-04-02T22:00:00Z",
                "messwertstatus": "GRUNDLAGE_POG_ERMITTLUNG",
                "obiskennzahl": "1-1:1.9.0",
                "wert": 500,
                "position": 1
              },
              {
                "startdatum": "2025-04-15T22:00:00Z",
                "enddatum": "2025-04-16T22:00:00Z",
                "messwertstatus": "GRUNDLAGE_POG_ERMITTLUNG",
                "obiskennzahl": "1-1:1.9.0",
                "wert": 750,
                "position": 1
              },
              {
                "startdatum": "2025-04-30T22:00:00Z",
                "enddatum": "2025-05-01T22:00:00Z",
                "messwertstatus": "GRUNDLAGE_POG_ERMITTLUNG",
                "obiskennzahl": "1-1:1.9.0",
                "wert": 1000.123,
                "position": 2
              }
            ]
          }
        ]
      },
      "transaktionsdaten": {
        "datenaustauschreferenz": "161201",
        "sparte": "STROM",
        "pruefidentifikator": "13028",
        "absender": {
          "boTyp": "MARKTTEILNEHMER",
          "versionStruktur": "1",
          "rollencodenummer": "9900321000005",
          "rollencodetyp": "BDEW"
        },
        "empfaenger": {
          "boTyp": "MARKTTEILNEHMER",
          "versionStruktur": "1",
          "rollencodenummer": "9904446000007",
          "rollencodetyp": "BDEW"
        },
        "dokumentennummer": "726947BGM",
        "kategorie": "Z85",
        "nachrichtenfunktion": "9",
        "nachrichtendatum": "2026-10-01T11:00:00Z",
        "nachrichtenreferenznummer": "726947",
        "typ": "EM"
      },
      "zusatzdaten": {}
    }
  }
]
```

</Beispielnachricht>

*Source: [`1.edi`](https://github.com/conuti-gmbh/maco-edi-testfiles/blob/main/inbound/v202610/mscons/13028/1.edi) · [`1.json`](https://github.com/conuti-gmbh/maco-edi-testfiles/blob/main/outbound/v202610/mscons/13028/1.json)*

<Testdateien edi="/testdaten/202610/mscons/13028/1.edi" json="/testdaten/202610/mscons/13028/1.json" />

</div>

## Belongs to these role views

The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are **LF** and **NB**.

<div className="maco-tabellenrahmen">

| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | [Transmission of information](/en/prozessdoku/202610/LF/GPKE-Teil4-uebermittlung-von-informationen) | GPKE part 4 | Electricity | Step 1 |
| NB | NB | [Transmission of information](/en/prozessdoku/202610/NB/GPKE-Teil4-uebermittlung-von-informationen) | GPKE part 4 | Electricity | Step 1 |

</div>

## Business classification

<div className="maco-tabellenrahmen">

| Attribute | Value |
|---|---|
| Use case (AHB) | Basis for POG determination |
| AHB | MSCONS AHB |
| Transmission channel | AS4 |

</div>

<div className="maco-tabellenrahmen">

| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| GPKE part 4 | Transmission of information | NB → MSB | Information |

</div>

## Transaction and responses

**Role of this check identifier: request.** Basis: the transaction data carry neither `antwortstatus` nor `antwortstatusCodeliste`, and neither the title nor the action of the Prüfi table begins with “response” or “response message”.

**Responses:** No response of this format version names this check identifier as a reference — neither explicitly in the Prüfi table nor via the step sequence. That does not mean there is none; it means that the sources do not record one.

**Check identifiers of the same AHB table:** No other check identifier of message type MSCONS has the same row structure in this version.

<Hinweisbereich>

An **\*** after a field or group name marks a **mandatory field** or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.

The status column carries two vocabularies because the manual answers two questions: on a **group row**, *Muss*, *Soll* or *Kann* states whether the EDIFACT segment must be present; on a **field row**, *X* states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.

For this check identifier, the application handbook lists **72 rows**. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.

The **Condition** column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.

The test data contains one transaction for this check identifier under the message type `mscons`. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.

:::note{title="Placeholder from the test data set"}

The test data set carries placeholders instead of valid values: `{{date}}` and `{{time}}` in the UNB interchange envelope of every EDIFACT file. **The page replaces these on call with the current date and the current time** — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.

`<businessKey>` stays in place. It is not a time value, and an invented key would look like a valid one.

:::

</Hinweisbereich>
