# Check identifier 17113 — Complaint about values

<span hidden data-pagefind-meta={"title:Check identifier 17113 — Complaint about values · ORDERS · Format version 202610"} />

Check identifier **17113** · EDIFACT message type **ORDERS** · Format version **202610**

## Data structure

<Handbuchsatz>

<div className="maco-tabellenrahmen">

| Structure (BO4E) | Description | Format | <span className="hbs-p" title="Reklamation von Werten">17113</span> | Condition |
|---|---|---|---|---|
| <span className="hbs-g hbs-e0">**stammdaten** <span className="hbs-pflicht">\*</span></span> | — | object | Must | — |
| <span className="hbs-g hbs-e1">**ANFRAGE** <span className="hbs-liste">[ ]</span> <span className="hbs-pflicht">\*</span></span> | — | object[] | Must | — |
| <span className="hbs-f hbs-e2">[anfragetyp](/en/bo4e/202610/bo/Anfrage#anfragetyp) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="17113" format="ORDERS" fv="202610" zeile={14} segment="IMD++[Z11\|Z12\|Z35]" /><span className="hbs-nr">00010</span> | Type/kind of the request (ORDERS ORDRSP IMD 7081) | [Enum Anfragetyp](/en/bo4e/202610/enum/Anfragetyp) | Must | — |
| <span className="hbs-w hbs-e3">`KAUF`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`NUTZUNGSUEBERLASSUNG`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`ABRECHNUNGSBRENNWERT_UND_ZUSTANDSZAHL`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`LASTGANGDATEN`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`ZAEHLERSTAENDE`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`WERTEERMITTLUNG`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`ENERGIEMENGE_EINZELWERT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`INNERHALB_DER_ARBEITSZEIT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`AUCH_AUSSERHALB_DER_ARBEITSZEIT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`WECHSEL_SAEMTLICHER_EINRICHTUNGEN`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`TEILWEISER_WECHSEL`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`AENDERUNG_ZAEHLZEITDEFINITION`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`ABBESTELLUNG_ZAEHLZEITEN`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`ABBESTELLUNG_MESSPRODUKT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`ANGEBOT_AUF_BASIS_PREISBLATT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`INDIVIDUELLES_ANGEBOT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`AENDERUNG_KONFIGURATION`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`KANN_NICHT_ANGEBOTEN_WERDEN`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`NEUKONFIGURATION`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`BEENDIGUNG_KONFIGURATION`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`AKTIVIERUNG_KONFIGURATION`</span> | — | — | Must | — |
| <span className="hbs-g hbs-e1">**AUFTRAG** <span className="hbs-liste">[ ]</span> <span className="hbs-pflicht">\*</span></span> | — | object[] | Must | — |
| <span className="hbs-g hbs-e2">**positionsdaten** <span className="hbs-liste">[ ]</span> <span className="hbs-pflicht">\*</span></span> | — | object[] | Must | — |
| <span className="hbs-f hbs-e3">[gueltigAb](/en/bo4e/202610/com/AuftragPosition#gueltigab)</span> <AhbTabelle pruefid="17113" format="ORDERS" fv="202610" zeile={58} segment="SG29.LIN.DTM+7" /><span className="hbs-nr">00020</span> | gueltigAb | string (date-time) | X | — |
| <span className="hbs-f hbs-e3">[positionsnummer](/en/bo4e/202610/com/AuftragPosition#positionsnummer) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="17113" format="ORDERS" fv="202610" zeile={52} segment="SG29.LIN" /><span className="hbs-nr">00030</span> | Line item number | integer | Must | — |
| <span className="hbs-g hbs-e1">**REKLAMATION** <span className="hbs-liste">[ ]</span> <span className="hbs-pflicht">\*</span></span> | — | object[] | Must | — |
| <span className="hbs-f hbs-e2">[konfiguration](/en/bo4e/202610/bo/Reklamation#konfiguration)</span> <AhbTabelle pruefid="17113" format="ORDERS" fv="202610" zeile={50} segment="SG2.NAD+MS.SG3.RFF+AGK" /><span className="hbs-nr">00040</span> | konfiguration | string | X | — |
| <span className="hbs-f hbs-e2">[lokationsId](/en/bo4e/202610/bo/Reklamation#lokationsid)</span> <AhbTabelle pruefid="17113" format="ORDERS" fv="202610" zeile={46} segment="SG2.NAD+DP.LOC+172" /><span className="hbs-nr">00050</span> | Which market or metering location this complaint applies to. | string | X | — |
| <span className="hbs-f hbs-e2">[obiskennzahl](/en/bo4e/202610/bo/Reklamation#obiskennzahl) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="17113" format="ORDERS" fv="202610" zeile={55} segment="SG29.LIN.PIA+5" /><span className="hbs-nr">00060</span> | OBIS code | string | X | — |
| <span className="hbs-f hbs-e2">[reklamationsgrund](/en/bo4e/202610/bo/Reklamation#reklamationsgrund) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="17113" format="ORDERS" fv="202610" zeile={70} segment="SG29.LIN.FTX+[Z04\|Z05\|Z06]" /><span className="hbs-nr">00070</span> | This specifies the reason for the complaint about values. | [Enum Reklamationsgrund](/en/bo4e/202610/enum/Reklamationsgrund) | Must | — |
| <span className="hbs-w hbs-e3">`WERTE_ZU_HOCH`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`WERTE_ZU_NIEDRIG`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`WERTE_FEHLEN`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`KONFIGURATION_WIRKT_NICHT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`KONFIGURATION_WIRKT_TEILWEISE`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`WERTE_WERDEN_NICHT_NACH_VORGABEN_UEBERMITTELT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`UEBERSICHT_FEHLT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`UEBERSICHT_UNPLAUSIBEL`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`AUSGEROLLTE_DEFINITION_FEHLT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`AUSGEROLLTE_DEFINITION_UNPLAUSIBEL`</span> | — | — | Must | — |
| <span className="hbs-g hbs-e2">**reklamationsgrundBemerkung**</span> | — | object | May | — |
| <span className="hbs-f hbs-e3">[bemerkung1](/en/bo4e/202610/com/ReklamationsgrundBemerkung#bemerkung1)</span> <AhbTabelle pruefid="17113" format="ORDERS" fv="202610" zeile={70} segment="SG29.LIN.FTX+[Z04\|Z05\|Z06]" /><span className="hbs-nr">00080</span> | bemerkung1 | string | Must | — |
| <span className="hbs-f hbs-e3">[bemerkung2](/en/bo4e/202610/com/ReklamationsgrundBemerkung#bemerkung2)</span> <AhbTabelle pruefid="17113" format="ORDERS" fv="202610" zeile={70} segment="SG29.LIN.FTX+[Z04\|Z05\|Z06]" /><span className="hbs-nr">00090</span> | bemerkung2 | string | Must | — |
| <span className="hbs-f hbs-e3">[bemerkung3](/en/bo4e/202610/com/ReklamationsgrundBemerkung#bemerkung3)</span> <AhbTabelle pruefid="17113" format="ORDERS" fv="202610" zeile={70} segment="SG29.LIN.FTX+[Z04\|Z05\|Z06]" /><span className="hbs-nr">00100</span> | bemerkung3 | string | Must | — |
| <span className="hbs-f hbs-e3">[bemerkung4](/en/bo4e/202610/com/ReklamationsgrundBemerkung#bemerkung4)</span> <AhbTabelle pruefid="17113" format="ORDERS" fv="202610" zeile={70} segment="SG29.LIN.FTX+[Z04\|Z05\|Z06]" /><span className="hbs-nr">00110</span> | bemerkung4 | string | Must | — |
| <span className="hbs-f hbs-e3">[bemerkung5](/en/bo4e/202610/com/ReklamationsgrundBemerkung#bemerkung5)</span> <AhbTabelle pruefid="17113" format="ORDERS" fv="202610" zeile={70} segment="SG29.LIN.FTX+[Z04\|Z05\|Z06]" /><span className="hbs-nr">00120</span> | bemerkung5 | string | Must | — |
| <span className="hbs-g hbs-e2">**zeitraumMesswertanfrage**</span> | — | object | May | — |
| <span className="hbs-f hbs-e3">[enddatum](/en/bo4e/202610/com/Zeitraum#enddatum)</span> <AhbTabelle pruefid="17113" format="ORDERS" fv="202610" zeile={66} segment="SG29.LIN.DTM+164" /><span className="hbs-nr">00130</span> | enddatum | string (date-time) | X | — |
| <span className="hbs-f hbs-e3">[startdatum](/en/bo4e/202610/com/Zeitraum#startdatum)</span> <AhbTabelle pruefid="17113" format="ORDERS" fv="202610" zeile={62} segment="SG29.LIN.DTM+163" /><span className="hbs-nr">00140</span> | startdatum | string (date-time) | X | — |
| <span className="hbs-g hbs-e0">**transaktionsdaten** <span className="hbs-pflicht">\*</span></span> | — | object | Must | — |
| <span className="hbs-f hbs-e1">[angebotsreferenz](/en/bo4e/202610/cdoc/Transaktionsdaten#angebotsreferenz)</span> <AhbTabelle pruefid="17113" format="ORDERS" fv="202610" zeile={19} segment="SG1.RFF+ACW" /><span className="hbs-nr">00150</span> | Reference number of a preceding message / ORDERS RFF+ACW | string | X | — |
| <span className="hbs-f hbs-e1">[dokumentennummer](/en/bo4e/202610/cdoc/Transaktionsdaten#dokumentennummer) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="17113" format="ORDERS" fv="202610" zeile={8} segment="BGM+Z34" /><span className="hbs-nr">00160</span> | EDIFACT reference from the BGM segment / BGM | string | X | — |
| <span className="hbs-f hbs-e1">[nachrichtendatum](/en/bo4e/202610/cdoc/Transaktionsdaten#nachrichtendatum) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="17113" format="ORDERS" fv="202610" zeile={11} segment="DTM+137" /><span className="hbs-nr">00170</span> | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| <span className="hbs-f hbs-e1">[nachrichtenreferenznummer](/en/bo4e/202610/cdoc/Transaktionsdaten#nachrichtenreferenznummer) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="17113" format="ORDERS" fv="202610" zeile={0} segment="UNH" /><span className="hbs-nr">00180</span> | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| <span className="hbs-f hbs-e1">[pruefidentifikator](/en/bo4e/202610/cdoc/Transaktionsdaten#pruefidentifikator) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="17113" format="ORDERS" fv="202610" zeile={22} segment="SG1.RFF+Z13" /><span className="hbs-nr">00190</span> | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| <span className="hbs-g hbs-e1">**absender** <span className="hbs-pflicht">\*</span></span> | — | object | Must | — |
| <span className="hbs-f hbs-e2">[rollencodenummer](/en/bo4e/202610/bo/Marktteilnehmer#rollencodenummer) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="17113" format="ORDERS" fv="202610" zeile={25} segment="SG2.NAD+MS" /><span className="hbs-nr">00200</span> | Specifies the code value of the market role. | string | X | — |
| <span className="hbs-f hbs-e2">[rollencodetyp](/en/bo4e/202610/bo/Marktteilnehmer#rollencodetyp) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="17113" format="ORDERS" fv="202610" zeile={25} segment="SG2.NAD+MS" /><span className="hbs-nr">00210</span> | Indicates the type of the code. | [Enum Rollencodetyp](/en/bo4e/202610/enum/Rollencodetyp) | X | — |
| <span className="hbs-w hbs-e3">`BDEW`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`GS1`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`GLN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`DVGW`</span> | — | — | X | — |
| <span className="hbs-g hbs-e2">**ansprechpartner** <span className="hbs-pflicht">\*</span></span> | — | object | Must | — |
| <span className="hbs-f hbs-e3">[eMailAdresse](/en/bo4e/202610/bo/Ansprechpartner#emailadresse)</span> <AhbTabelle pruefid="17113" format="ORDERS" fv="202610" zeile={32} segment="SG2.NAD+MS.SG5.CTA+IC.COM+[EM\|FX\|TE\|AJ\|AL]" /><span className="hbs-nr">00220</span> | Email address | string | Must | — |
| <span className="hbs-f hbs-e3">[nachname](/en/bo4e/202610/bo/Ansprechpartner#nachname) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="17113" format="ORDERS" fv="202610" zeile={30} segment="SG2.NAD+MS.SG5.CTA+IC" /><span className="hbs-nr">00230</span> | Surname (family name) of the contact person | string | X | — |
| <span className="hbs-g hbs-e3">**rufnummern** <span className="hbs-liste">[ ]</span></span> | — | object[] | May | — |
| <span className="hbs-f hbs-e4">[nummerntyp](/en/bo4e/202610/com/Rufnummer#nummerntyp)</span> <AhbTabelle pruefid="17113" format="ORDERS" fv="202610" zeile={32} segment="SG2.NAD+MS.SG5.CTA+IC.COM+[EM\|FX\|TE\|AJ\|AL]" /><span className="hbs-nr">00240</span> | Phone number type | [Enum Rufnummernart](/en/bo4e/202610/enum/Rufnummernart) | Must | — |
| <span className="hbs-w hbs-e5">`RUF_ZENTRALE`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`FAX_ZENTRALE`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`SAMMELRUF`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`SAMMELFAX`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`ABTEILUNGRUF`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`ABTEILUNGFAX`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`RUF_DURCHWAHL`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`FAX_DURCHWAHL`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`MOBIL_NUMMER`</span> | — | — | Must | — |
| <span className="hbs-f hbs-e4">[rufnummer](/en/bo4e/202610/com/Rufnummer#rufnummer)</span> <AhbTabelle pruefid="17113" format="ORDERS" fv="202610" zeile={32} segment="SG2.NAD+MS.SG5.CTA+IC.COM+[EM\|FX\|TE\|AJ\|AL]" /><span className="hbs-nr">00250</span> | rufnummer | string | Must | — |
| <span className="hbs-g hbs-e1">**empfaenger** <span className="hbs-pflicht">\*</span></span> | — | object | Must | — |
| <span className="hbs-f hbs-e2">[rollencodenummer](/en/bo4e/202610/bo/Marktteilnehmer#rollencodenummer) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="17113" format="ORDERS" fv="202610" zeile={40} segment="SG2.NAD+MR" /><span className="hbs-nr">00260</span> | Specifies the code value of the market role. | string | X | — |
| <span className="hbs-f hbs-e2">[rollencodetyp](/en/bo4e/202610/bo/Marktteilnehmer#rollencodetyp) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="17113" format="ORDERS" fv="202610" zeile={40} segment="SG2.NAD+MR" /><span className="hbs-nr">00270</span> | Indicates the type of the code. | [Enum Rollencodetyp](/en/bo4e/202610/enum/Rollencodetyp) | X | — |
| <span className="hbs-w hbs-e3">`BDEW`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`GS1`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`GLN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`DVGW`</span> | — | — | X | — |

</div>

</Handbuchsatz>

## Application handbook (AHB)

<Handbuchsatz>

<div className="maco-tabellenrahmen" data-maco="ahb-tabelle">

| Structure (EDIFACT) | Description | Format | <span className="hbs-p" title="Reklamation von Werten">17113</span> | Condition |
|---|---|---|---|---|
| <span className="hbs-g hbs-e0">**UNH**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`0062`</span><span className="hbs-nr">00010</span> | Message reference number | — | X | — |
| <span className="hbs-f hbs-e1">`0065 ORDERS`</span><span className="hbs-nr">00020</span> | Order placement | — | X | — |
| <span className="hbs-f hbs-e1">`0052 D`</span><span className="hbs-nr">00030</span> | Draft version | — | X | — |
| <span className="hbs-f hbs-e1">`0054 09B`</span><span className="hbs-nr">00040</span> | Edition 2009 - B | — | X | — |
| <span className="hbs-f hbs-e1">`0051 UN`</span><span className="hbs-nr">00050</span> | UN/CEFACT | — | X | — |
| <span className="hbs-f hbs-e1">`0057 1.4c`</span><span className="hbs-nr">00060</span> | Version number of the underlying BDEW message description | — | X | — |
| <span className="hbs-g hbs-e0">**BGM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1001 Z34`</span><span className="hbs-nr">00070</span> | Complaint about values | — | X | — |
| <span className="hbs-f hbs-e1">`1004`</span><span className="hbs-nr">00080</span> | Document number | — | X | — |
| <span className="hbs-g hbs-e0">**DTM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`2005 137`</span><span className="hbs-nr">00090</span> | Document-/message date/time | — | X | — |
| <span className="hbs-f hbs-e1">`2380`</span><span className="hbs-nr">00100</span> | Date or time or time span, value | — | X | <span className="hbs-marke">[931]</span> <span className="hbs-marke">[494]</span> |
| <span className="hbs-f hbs-e1">`2379 303`</span><span className="hbs-nr">00110</span> | CCYYMMDDHHMMZZZ | — | X | — |
| <span className="hbs-g hbs-e0">**IMD**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7081 Z11`</span><span className="hbs-nr">00120</span> | Load curve data | — | X | — |
| <span className="hbs-f hbs-e1">`7081 Z12`</span><span className="hbs-nr">00130</span> | Meter readings | — | X | — |
| <span className="hbs-f hbs-e1">`7081 Z35`</span><span className="hbs-nr">00140</span> | Energy quantity single value | — | X | — |
| <span className="hbs-g hbs-e0">**SG1.RFF**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1153 ACW`</span><span className="hbs-nr">00150</span> | Reference number of a preceding message | — | X | — |
| <span className="hbs-f hbs-e1">`1154`</span><span className="hbs-nr">00160</span> | Message number | — | X | <span className="hbs-marke">[525]</span> |
| <span className="hbs-g hbs-e0">**SG1.RFF**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1153 Z13`</span><span className="hbs-nr">00170</span> | Check identifier | — | X | — |
| <span className="hbs-f hbs-e1">`1154 17113`</span><span className="hbs-nr">00180</span> | Notification of a complaint about values | — | X | — |
| <span className="hbs-g hbs-e0">**SG2.NAD**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3035 MS`</span><span className="hbs-nr">00190</span> | Document-/message sender or sender | — | X | — |
| <span className="hbs-f hbs-e1">`3039`</span><span className="hbs-nr">00200</span> | MP-ID | — | X | <span className="hbs-marke">[61]</span> |
| <span className="hbs-f hbs-e1">`3055 9`</span><span className="hbs-nr">00210</span> | GS1 | — | X | — |
| <span className="hbs-f hbs-e1">`3055 293`</span><span className="hbs-nr">00220</span> | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| <span className="hbs-g hbs-e0">**SG5.CTA**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3139 IC`</span><span className="hbs-nr">00230</span> | Information contact | — | X | — |
| <span className="hbs-f hbs-e1">`3412`</span><span className="hbs-nr">00240</span> | Contact | — | X | — |
| <span className="hbs-g hbs-e0">**SG5.COM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3148`</span><span className="hbs-nr">00250</span> | Communication address, identification | — | X | ((<span className="hbs-marke">[939]</span> <span className="hbs-marke">[147]</span>) ⊻ (<span className="hbs-marke">[940]</span> <span className="hbs-marke">[148]</span>)) ∧ <span className="hbs-marke">[567]</span> |
| <span className="hbs-f hbs-e1">`3155 EM`</span><span className="hbs-nr">00260</span> | Electronic mail | — | X | <span className="hbs-marke">[1P0..1]</span> |
| <span className="hbs-f hbs-e1">`3155 FX`</span><span className="hbs-nr">00270</span> | Fax number | — | X | <span className="hbs-marke">[1P0..1]</span> |
| <span className="hbs-f hbs-e1">`3155 TE`</span><span className="hbs-nr">00280</span> | Telephone | — | X | <span className="hbs-marke">[1P0..1]</span> |
| <span className="hbs-f hbs-e1">`3155 AJ`</span><span className="hbs-nr">00290</span> | further telephone | — | X | <span className="hbs-marke">[1P0..1]</span> |
| <span className="hbs-f hbs-e1">`3155 AL`</span><span className="hbs-nr">00300</span> | Mobile phone | — | X | <span className="hbs-marke">[1P0..1]</span> |
| <span className="hbs-g hbs-e0">**SG2.NAD**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3035 MR`</span><span className="hbs-nr">00310</span> | Message recipient | — | X | — |
| <span className="hbs-f hbs-e1">`3039`</span><span className="hbs-nr">00320</span> | MP-ID | — | X | <span className="hbs-marke">[61]</span> |
| <span className="hbs-f hbs-e1">`3055 9`</span><span className="hbs-nr">00330</span> | GS1 | — | X | — |
| <span className="hbs-f hbs-e1">`3055 293`</span><span className="hbs-nr">00340</span> | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| <span className="hbs-g hbs-e0">**SG2.NAD**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3035 DP`</span><span className="hbs-nr">00350</span> | Supply address | — | X | — |
| <span className="hbs-g hbs-e0">**SG2.LOC**</span> | — | — | Must | <span className="hbs-marke">[24]</span> ⊻ <span className="hbs-marke">[18]</span> ⊻ (<span className="hbs-marke">[108]</span> ∧ <span className="hbs-marke">[19]</span>) |
| <span className="hbs-f hbs-e1">`3227 172`</span><span className="hbs-nr">00360</span> | Reporting point | — | X | — |
| <span className="hbs-f hbs-e1">`3225`</span><span className="hbs-nr">00370</span> | Identifier | — | X | ((<span className="hbs-marke">[950]</span> <span className="hbs-marke">[521]</span> ∧ (<span className="hbs-marke">[6]</span> ⊻ <span className="hbs-marke">[7]</span> ⊻ <span className="hbs-marke">[26]</span>)) ⊻ (<span className="hbs-marke">[951]</span> <span className="hbs-marke">[522]</span> ∧ (<span className="hbs-marke">[6]</span> ⊻ <span className="hbs-marke">[7]</span> ⊻ <span className="hbs-marke">[15]</span>)) ⊻ (<span className="hbs-marke">[950]</span> <span className="hbs-marke">[523]</span> ∧ (<span className="hbs-marke">[6]</span> ⊻ <span className="hbs-marke">[7]</span> ⊻ <span className="hbs-marke">[26]</span>))) |
| <span className="hbs-g hbs-e0">**SG3.RFF**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1153 AGK`</span><span className="hbs-nr">00380</span> | Application reference number | — | X | — |
| <span className="hbs-f hbs-e1">`1154`</span><span className="hbs-nr">00390</span> | Configuration ID | — | X | — |
| <span className="hbs-g hbs-e0">**SG29.LIN**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1082`</span><span className="hbs-nr">00400</span> | Line item number | — | X | <span className="hbs-marke">[911]</span> |
| <span className="hbs-g hbs-e0">**SG29.PIA**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`4347 5`</span><span className="hbs-nr">00410</span> | Product identification | — | X | — |
| <span className="hbs-f hbs-e1">`7140`</span><span className="hbs-nr">00420</span> | OBIS code | — | X | — |
| <span className="hbs-f hbs-e1">`7143 SRW`</span><span className="hbs-nr">00430</span> | OBIS code | — | X | — |
| <span className="hbs-g hbs-e0">**SG29.DTM**</span> | — | — | Must | <span className="hbs-marke">[19]</span> ∧ <span className="hbs-marke">[67]</span> ∧ <span className="hbs-marke">[549]</span> |
| <span className="hbs-f hbs-e1">`2005 7`</span><span className="hbs-nr">00440</span> | Effective date/time | — | X | — |
| <span className="hbs-f hbs-e1">`2380`</span><span className="hbs-nr">00450</span> | Date or time or time span, value | — | X | <span className="hbs-marke">[931]</span> |
| <span className="hbs-f hbs-e1">`2379 303`</span><span className="hbs-nr">00460</span> | CCYYMMDDHHMMZZZ | — | X | — |
| <span className="hbs-g hbs-e0">**SG29.DTM**</span> | — | — | Must | <span className="hbs-marke">[18]</span> ⊻ <span className="hbs-marke">[24]</span> ⊻ (<span className="hbs-marke">[19]</span> ∧ <span className="hbs-marke">[54]</span> ∧ <span className="hbs-marke">[68]</span> ∧ <span className="hbs-marke">[550]</span>) |
| <span className="hbs-f hbs-e1">`2005 163`</span><span className="hbs-nr">00470</span> | Processing, start date/time | — | X | — |
| <span className="hbs-f hbs-e1">`2380`</span><span className="hbs-nr">00480</span> | Date or time or time span, value | — | X | <span className="hbs-marke">[931]</span> |
| <span className="hbs-f hbs-e1">`2379 303`</span><span className="hbs-nr">00490</span> | CCYYMMDDHHMMZZZ | — | X | — |
| <span className="hbs-g hbs-e0">**SG29.DTM**</span> | — | — | Must | <span className="hbs-marke">[110]</span> |
| <span className="hbs-f hbs-e1">`2005 164`</span><span className="hbs-nr">00500</span> | Processing, end date/time | — | X | — |
| <span className="hbs-f hbs-e1">`2380`</span><span className="hbs-nr">00510</span> | Date or time or time span, value | — | X | <span className="hbs-marke">[931]</span> |
| <span className="hbs-f hbs-e1">`2379 303`</span><span className="hbs-nr">00520</span> | CCYYMMDDHHMMZZZ | — | X | — |
| <span className="hbs-g hbs-e0">**SG29.FTX**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`4451 Z04`</span><span className="hbs-nr">00530</span> | Values too high in the specified time interval | — | X | — |
| <span className="hbs-f hbs-e1">`4451 Z05`</span><span className="hbs-nr">00540</span> | Values too low in the specified time interval | — | X | — |
| <span className="hbs-f hbs-e1">`4451 Z06`</span><span className="hbs-nr">00550</span> | Values missing in the specified time interval | — | X | — |
| <span className="hbs-f hbs-e1">`4440`</span><span className="hbs-nr">00560</span> | Description of the complaint | — | — | — |
| <span className="hbs-g hbs-e0">**UNS**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`0081 S`</span><span className="hbs-nr">00570</span> | Separation of detail and summary section | — | X | — |
| <span className="hbs-g hbs-e0">**UNT**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`0074`</span><span className="hbs-nr">00580</span> | Number of segments in a message | — | X | — |
| <span className="hbs-f hbs-e1">`0062`</span><span className="hbs-nr">00590</span> | Message reference number | — | X | — |

</div>

</Handbuchsatz>

### Conditions of this table

The free text of the 30 conditions referenced by the rows above. All conditions of the message type are listed in the [condition index ORDERS](/en/referenz/202610/ahb-bedingungen/ORDERS).

<div className="maco-tabellenrahmen">

| Marker | Condition |
|---|---|
| **[6]** | If MP-ID in SG2 NAD+MS with role LF is present |
| **[7]** | If MP-ID in SG2 NAD+MS with role NB is present |
| **[15]** | If MP-ID in SG2 NAD+MS with role MSB is present |
| **[18]** | If IMD++Z11 present |
| **[19]** | If IMD++Z12 present |
| **[24]** | If IMD++Z35 present |
| **[26]** | If MP-ID in SG2 NAD+MS with role ÜNB is present |
| **[54]** | If FTX+Z06 present |
| **[61]** | MP-ID only from division electricity |
| **[67]** | If DTM+163 not present |
| **[68]** | If DTM+7 not present |
| **[108]** | If RFF+AGK (configuration ID) not present |
| **[110]** | If DTM+163 (start of time period for value request) present |
| **[147]** | If code EM is present in DE3155 in the same COM |
| **[148]** | If code TE / FX / AJ / AL is present in DE3155 in the same COM |
| **[494]** | The date stated here must be the point in time at which the document was created, or a point in time before that. |
| **[521]** | Note: Use of the ID of the market location |
| **[522]** | Note: Use of the ID of the metering location |
| **[523]** | Note: Use of the ID of the tranche |
| **[525]** | Note: Value from BGM DE1004 of the MSCONS |
| **[549]** | Note: Always applies to the complaint about meter readings. The only exception is a complaint about a missing meter reading due to a periodic meter reading for which the MSB had transmitted the information on the "planned periodic meter reading of the MSB (electricity)" at the object of the market location in the UTILMD in SG6 DTM+752 as the reading period (DE2379 with code 104 MMWW-MMWW) in the previous master data, because in that case no point in time can be specified and the time interval in the segment form DTM+163 / DTM+164 must be used. |
| **[550]** | Note: Applies only if it is a complaint about a missing meter reading due to a periodic meter reading for which the MSB had transmitted the information on the "planned periodic meter reading of the MSB (electricity)" at the object of the market location in the UTILMD in SG6 DTM+752 as the reading period (DE2379 with code 104 MMWW-MMWW) in the previous master data. |
| **[567]** | Note: Only one piece of information may be transmitted in DE3148 |
| **[911]** | Format: Possible values: 1 to n, starting at 1 for each message or segment group and ascending consecutively |
| **[931]** | Format: ZZZ = +00 |
| **[939]** | Format: the character string must contain the characters @ and . |
| **[940]** | Format: the character string must begin with the character + and may only be followed by digits |
| **[950]** | Format: market location ID |
| **[951]** | Format: Metering point identifier |
| **[1P0..1]** | Note: This is the standard package if no condition applies, e.g. in the COM segment. |

</div>

## Example message

<div data-maco="beispielfall" className="maco-beispielfall">

<Beispielnachricht>

```text title="EDIFACT"
UNA:+.? '
UNB+UNOC:3+9903111000003:500+9904629000006:500+{{date}}:{{time}}+M0OYS007'
UNH+M104QEDN+ORDERS:D:09B:UN:1.4c'
BGM+Z34+M0HC9M6V'
DTM+137:202610011100?+00:303'
IMD++Z11'
RFF+ACW:12345'
RFF+Z13:17113'
NAD+MS+9903111000003::293'
CTA+IC+:Andre Laue'
COM+marktpartner @stromnetz-hamburg.de:EM'
NAD+MR+9904629000006::293'
NAD+DP'
LOC+172+55123678945'
LIN+1'
PIA+5+1?:1.1.9.0:SRW'
DTM+163:202604282200?+00:303'
DTM+164:202608112200?+00:303'
FTX+Z04'
UNS+S'
UNT+19+M104QEDN'
UNZ+1+M0OYS007'
```

```json title="BO4E-JSON"
[
  {
    "businessKey": "<businessKey>",
    "processDate": null,
    "dataSource": "OUTBOUND",
    "version": 1,
    "edifactVersion": 202610,
    "data": {
      "stammdaten": {
        "ANFRAGE": [
          {
            "boTyp": "ANFRAGE",
            "versionStruktur": "1",
            "anfragekategorie": "REKLAMATION_VON_WERTEN",
            "anfragetyp": "LASTGANGDATEN"
          }
        ],
        "AUFTRAG": [
          {
            "boTyp": "AUFTRAG",
            "versionStruktur": "1",
            "positionsdaten": [
              {
                "positionsnummer": 1
              }
            ]
          }
        ],
        "REKLAMATION": [
          {
            "boTyp": "REKLAMATION",
            "versionStruktur": "1",
            "lokationsId": "55123678945",
            "lokationsTyp": "MALO",
            "obiskennzahl": "1:1.1.9.0",
            "zeitraumMesswertanfrage": {
              "startdatum": "2026-04-28T22:00:00Z",
              "enddatum": "2026-08-11T22:00:00Z"
            },
            "reklamationsgrund": "WERTE_ZU_HOCH"
          }
        ]
      },
      "transaktionsdaten": {
        "datenaustauschreferenz": "M0OYS007",
        "sparte": "STROM",
        "pruefidentifikator": "17113",
        "absender": {
          "boTyp": "MARKTTEILNEHMER",
          "versionStruktur": "1",
          "marktrolle": "LF",
          "rollencodenummer": "9903111000003",
          "rollencodetyp": "BDEW",
          "ansprechpartner": {
            "boTyp": "ANSPRECHPARTNER",
            "versionStruktur": "1",
            "nachname": "Andre Laue",
            "eMailAdresse": "marktpartner @stromnetz-hamburg.de"
          }
        },
        "empfaenger": {
          "boTyp": "MARKTTEILNEHMER",
          "versionStruktur": "1",
          "marktrolle": "MSB",
          "rollencodenummer": "9904629000006",
          "rollencodetyp": "BDEW"
        },
        "dokumentennummer": "M0HC9M6V",
        "nachrichtendatum": "2026-10-01T11:00:00Z",
        "nachrichtenreferenznummer": "M104QEDN",
        "angebotsreferenz": "12345"
      },
      "zusatzdaten": {}
    }
  }
]
```

</Beispielnachricht>

*Source: [`1.edi`](https://github.com/conuti-gmbh/maco-edi-testfiles/blob/main/inbound/v202610/orders/17113/1.edi) · [`1.json`](https://github.com/conuti-gmbh/maco-edi-testfiles/blob/main/outbound/v202610/orders/17113/1.json)*

<Testdateien edi="/testdaten/202610/orders/17113/1.edi" json="/testdaten/202610/orders/17113/1.json" />

</div>

## Belongs to these role views

The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are **LF**, **NB**, **MSB** and **ÜNB**.

<div className="maco-tabellenrahmen">

| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | [Complaint from the LF](/en/prozessdoku/202610/LF/WiM-Teil2-reklamation-vom-lf) | WiM electricity part 2 | Electricity | Step 1 |
| LF | LF | [Complaint from the LF](/en/prozessdoku/202610/LF/WiM-Teil2-reklamation-vom-lf) | WiM electricity part 2 | Electricity | Step 5 |
| NB | NB | [Complaint from the NB](/en/prozessdoku/202610/NB/WiM-Teil2-reklamation-vom-nb) | WiM electricity part 2 | Electricity | Step 1 |
| NB | NB | [Complaint from the NB](/en/prozessdoku/202610/NB/WiM-Teil2-reklamation-vom-nb) | WiM electricity part 2 | Electricity | Step 5 |
| MSB | MSB-MALO | [MSB of the market location identifies the need for a complaint itself](/en/prozessdoku/202610/MSB--MSB-MALO/WiM-Teil2-msb-der-marktlokation-stellt-selbst-reklamationsbedarf-fest) | WiM electricity part 2 | Electricity | Step 3 |
| MSB | MSB-MALO | [Complaint from the LF](/en/prozessdoku/202610/MSB--MSB-MALO/WiM-Teil2-reklamation-vom-lf) | WiM electricity part 2 | Electricity | Step 1 |
| MSB | MSB-MALO | [Complaint from the LF](/en/prozessdoku/202610/MSB--MSB-MALO/WiM-Teil2-reklamation-vom-lf) | WiM electricity part 2 | Electricity | Step 5 |
| MSB | MSB-MALO | [Complaint from the NB](/en/prozessdoku/202610/MSB--MSB-MALO/WiM-Teil2-reklamation-vom-nb) | WiM electricity part 2 | Electricity | Step 1 |
| MSB | MSB-MALO | [Complaint from the NB](/en/prozessdoku/202610/MSB--MSB-MALO/WiM-Teil2-reklamation-vom-nb) | WiM electricity part 2 | Electricity | Step 5 |
| MSB | MSB-MALO | [Complaint from the ÜNB](/en/prozessdoku/202610/MSB--MSB-MALO/WiM-Teil2-reklamation-vom-uenb) | WiM electricity part 2 | Electricity | Step 1 |
| MSB | MSB-MALO | [Complaint from the ÜNB](/en/prozessdoku/202610/MSB--MSB-MALO/WiM-Teil2-reklamation-vom-uenb) | WiM electricity part 2 | Electricity | Step 5 |
| MSB | MSB-MELO | [MSB of the market location identifies the need for a complaint itself](/en/prozessdoku/202610/MSB--MSB-MELO/WiM-Teil2-msb-der-marktlokation-stellt-selbst-reklamationsbedarf-fest) | WiM electricity part 2 | Electricity | Step 3 |
| MSB | MSB-MELO | [Complaint from the LF](/en/prozessdoku/202610/MSB--MSB-MELO/WiM-Teil2-reklamation-vom-lf) | WiM electricity part 2 | Electricity | Step 1 |
| MSB | MSB-MELO | [Complaint from the LF](/en/prozessdoku/202610/MSB--MSB-MELO/WiM-Teil2-reklamation-vom-lf) | WiM electricity part 2 | Electricity | Step 5 |
| MSB | MSB-MELO | [Complaint from the NB](/en/prozessdoku/202610/MSB--MSB-MELO/WiM-Teil2-reklamation-vom-nb) | WiM electricity part 2 | Electricity | Step 1 |
| MSB | MSB-MELO | [Complaint from the NB](/en/prozessdoku/202610/MSB--MSB-MELO/WiM-Teil2-reklamation-vom-nb) | WiM electricity part 2 | Electricity | Step 5 |
| MSB | MSB-MELO | [Complaint from the ÜNB](/en/prozessdoku/202610/MSB--MSB-MELO/WiM-Teil2-reklamation-vom-uenb) | WiM electricity part 2 | Electricity | Step 1 |
| MSB | MSB-MELO | [Complaint from the ÜNB](/en/prozessdoku/202610/MSB--MSB-MELO/WiM-Teil2-reklamation-vom-uenb) | WiM electricity part 2 | Electricity | Step 5 |
| ÜNB | ÜNB | [Complaint from the ÜNB](/en/prozessdoku/202610/UENB/WiM-Teil2-reklamation-vom-uenb) | WiM electricity part 2 | Electricity | Step 1 |
| ÜNB | ÜNB | [Complaint from the ÜNB](/en/prozessdoku/202610/UENB/WiM-Teil2-reklamation-vom-uenb) | WiM electricity part 2 | Electricity | Step 5 |

</div>

## Business classification

<div className="maco-tabellenrahmen">

| Attribute | Value |
|---|---|
| Use case (AHB) | Complaint about values |
| AHB | ORDERS AHB |
| Transmission channel | AS4 |

</div>

:::caution{title="This check identifier is used in 8 contexts"}

Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.

:::

<div className="maco-tabellenrahmen">

| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| WiM electricity part 2 | Complaint from the NB | NB → MSB (corresponds to MSB on the market location object) | Complaint value |
| WiM electricity part 2 | Complaint from the NB | MSB (corresponds to MSB on the object market location) → MSB (corresponds to MSB on the object metering location) | Complaint value of a metering location |
| WiM electricity part 2 | Complaint from the LF | LF → MSB (corresponds to MSB on the market location object) | Complaint value |
| WiM electricity part 2 | Complaint from the LF | MSB (corresponds to MSB on the object market location) → MSB (corresponds to MSB on the object metering location) | Complaint value of a metering location |
| WiM electricity part 2 | Complaint from the ÜNB | ÜNB → MSB (corresponds to MSB on the market location object) | Complaint value |
| WiM electricity part 2 | Complaint from the ÜNB | MSB (corresponds to MSB on the object market location) → MSB (corresponds to MSB on the object metering location) | Complaint value of a metering location |
| WiM electricity part 2 | MSB of the market location itself identifies a need for complaint | MSB (corresponds to MSB on the object market location) → MSB (corresponds to MSB on the object metering location) | Complaint value of a metering location |
| WiM gas | Ch. C 4.3.3.2 No. 1 | LF → NB | Notification of a complaint |

</div>

:::caution{title="Individual entries from format version 202604"}

The check identifiers table of format version 202610 does not carry this entry: **process step**. It comes from version 202604. Version 202604 also carries this check identifier in contexts that the table of version 202610 does not know; they are included in the list above. Everything else on this page — use case, rulebook and communication direction — comes from its own version. Before adopting this into an implementation specification, check whether what is stated applies to 202610.

:::

## Transaction and responses

**Role of this check identifier: request.** Basis: the transaction data carry neither `antwortstatus` nor `antwortstatusCodeliste`, and neither the title nor the action of the Prüfi table begins with “response” or “response message”.

### Which messages respond to this

<div className="maco-tabellenrahmen">

| Role | Check identifier | Use case | Message type | Origin of supply |
|---|---|---|---|---|
| Response | [19114](/schnittstellen/202610/pruefi/ORDRSP/PI_19114) | Rejection of complaint | ORDRSP | from the step sequence |

</div>

This column is the **inverse** of the assignment on the response pages — not the next step of a list. The process source says of its own steps that they are »possible messages, not a sequence«.

**Check identifiers of the same AHB table:** No other check identifier of message type ORDERS has the same row structure in this version.

:::note{title="Editorial — not derived from a source"}

**What the complaint refers to.** The complaint cites the disputed message via `RFF+ACW` (reference number of a previous message), in the JSON `transaktionsdaten.angebotsreferenz` (`SG1.RFF+ACW`). It carries no `anfrageReferenz` (`RFF+AGI`): only the meter reading messages (MSCONS), IFTSTA 21042 to 21044 and UTILTS 25004 to 25009 carry one. Example from the test set (17113): `RFF+ACW:ABC1234`.

**Source:** ORDERS AHB (Knowledge Collection ahb/202604/ORDERS/17113.json and ahb/202610/ORDERS/17113.json, SG1 RFF+ACW); specification PI_17113 (segment mapping of angebotsreferenz); test set maco-edi-testfiles, inbound/v202404/ORDERS/17113_eingehend.edi · **As of:** 2026-09-23 · **Applies to format version:** 202604, 202610 · **To be reviewed by:** 2027-04-01

:::

<Hinweisbereich>

An **\*** after a field or group name marks a **mandatory field** or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.

The status column carries two vocabularies because the manual answers two questions: on a **group row**, *Muss*, *Soll* or *Kann* states whether the EDIFACT segment must be present; on a **field row**, *X* states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.

For this check identifier, the application handbook lists **80 rows**. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.

The **Condition** column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.

The test data contains one transaction for this check identifier under the message type `orders`. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.

:::note{title="Placeholder from the test data set"}

The test data set carries placeholders instead of valid values: `{{date}}` and `{{time}}` in the UNB interchange envelope of every EDIFACT file. **The page replaces these on call with the current date and the current time** — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.

`<businessKey>` stays in place. It is not a time value, and an invented key would look like a valid one.

:::

</Hinweisbereich>