# Check identifier 15001 — Quotation device takeover

<span hidden data-pagefind-meta={"title:Check identifier 15001 — Quotation device takeover · QUOTES · Format version 202610"} />

Check identifier **15001** · EDIFACT message type **QUOTES** · Format version **202610**

## Data structure

<Handbuchsatz>

<div className="maco-tabellenrahmen">

| Structure (BO4E) | Description | Format | <span className="hbs-p" title="Angebot Geräteübernahme">15001</span> | Condition |
|---|---|---|---|---|
| <span className="hbs-g hbs-e0">**stammdaten** <span className="hbs-pflicht">\*</span></span> | — | object | Must | — |
| <span className="hbs-g hbs-e1">**ANFRAGE** <span className="hbs-liste">[ ]</span> <span className="hbs-pflicht">\*</span></span> | — | object[] | Must | — |
| <span className="hbs-f hbs-e2">[anfragetyp](/en/bo4e/202610/bo/Anfrage#anfragetyp) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="15001" format="QUOTES" fv="202610" zeile={18} segment="IMD++[Z07\|Z08]" /><span className="hbs-nr">00010</span> | Type/kind of the request (ORDERS ORDRSP IMD 7081) | [Enum Anfragetyp](/en/bo4e/202610/enum/Anfragetyp) | Must | — |
| <span className="hbs-w hbs-e3">`KAUF`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`NUTZUNGSUEBERLASSUNG`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`ABRECHNUNGSBRENNWERT_UND_ZUSTANDSZAHL`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`LASTGANGDATEN`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`ZAEHLERSTAENDE`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`WERTEERMITTLUNG`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`ENERGIEMENGE_EINZELWERT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`INNERHALB_DER_ARBEITSZEIT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`AUCH_AUSSERHALB_DER_ARBEITSZEIT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`WECHSEL_SAEMTLICHER_EINRICHTUNGEN`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`TEILWEISER_WECHSEL`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`AENDERUNG_ZAEHLZEITDEFINITION`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`ABBESTELLUNG_ZAEHLZEITEN`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`ABBESTELLUNG_MESSPRODUKT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`ANGEBOT_AUF_BASIS_PREISBLATT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`INDIVIDUELLES_ANGEBOT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`AENDERUNG_KONFIGURATION`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`KANN_NICHT_ANGEBOTEN_WERDEN`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`NEUKONFIGURATION`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`BEENDIGUNG_KONFIGURATION`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`AKTIVIERUNG_KONFIGURATION`</span> | — | — | Must | — |
| <span className="hbs-g hbs-e1">**ANGEBOT** <span className="hbs-liste">[ ]</span> <span className="hbs-pflicht">\*</span></span> | — | object[] | Must | — |
| <span className="hbs-f hbs-e2">[anfragereferenz](/en/bo4e/202610/bo/Angebot#anfragereferenz) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="15001" format="QUOTES" fv="202610" zeile={22} segment="SG1.RFF+AAV" /><span className="hbs-nr">00020</span> | Reference to a request or tender. Can help the recipient of the quotation to assign the quotation to the request or tender. | string | X | — |
| <span className="hbs-f hbs-e2">[angebotsdatum](/en/bo4e/202610/bo/Angebot#angebotsdatum) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="15001" format="QUOTES" fv="202610" zeile={15} segment="DTM+76" /><span className="hbs-nr">00030</span> | Creation date of the quotation | string (date-time) | X | — |
| <span className="hbs-g hbs-e2">**positionsdaten** <span className="hbs-liste">[ ]</span> <span className="hbs-pflicht">\*</span></span> | — | object[] | Must | — |
| <span className="hbs-f hbs-e3">[anbietbar](/en/bo4e/202610/com/Angebotsposition#anbietbar)</span> <AhbTabelle pruefid="15001" format="QUOTES" fv="202610" zeile={62} segment="SG27.LIN.IMD++Z09" /><span className="hbs-nr">00040</span> | — | boolean | Should | <span className="hbs-marke">[1]</span> |
| <span className="hbs-f hbs-e3">[artikelnummer](/en/bo4e/202610/com/Angebotsposition#artikelnummer) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="15001" format="QUOTES" fv="202610" zeile={58} segment="SG27.LIN" /><span className="hbs-nr">00050</span> | BDEW article number | [Enum BDEWArtikelnummer](/en/bo4e/202610/enum/BDEWArtikelnummer) | Must | — |
| <span className="hbs-w hbs-e4">`LEISTUNG`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`LEISTUNG_PAUSCHAL`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`GRUNDPREIS`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`REGELENERGIE_ARBEIT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`REGELENERGIE_LEISTUNG`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`NOTSTROMLIEFERUNG_ARBEIT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`NOTSTROMLIEFERUNG_LEISTUNG`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`RESERVENETZKAPAZITAET`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`RESERVELEISTUNG`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`ZUSAETZLICHE_ABLESUNG`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`PRUEFGEBUEHREN_AUSSERPLANMAESSIG`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`WIRKARBEIT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`SINGULAER_GENUTZTE_BETRIEBSMITTEL`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`ABGABE_KWKG`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`ABSCHLAG`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`KONZESSIONSABGABE`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`ENTGELT_FERNAUSLESUNG`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`UNTERMESSUNG`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`BLINDMEHRARBEIT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`ENTGELT_ABRECHNUNG`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`SPERRKOSTEN`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`ENTSPERRKOSTEN`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`MAHNKOSTEN`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`MEHR_MINDERMENGEN`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`INKASSOKOSTEN`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`BLINDMEHRLEISTUNG`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`ENTGELT_MESSUNG_ABLESUNG`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`ENTGELT_EINBAU_BETRIEB_WARTUNG_MESSTECHNIK`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`AUSGLEICHSENERGIE`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`AUSGLEICHSENERGIE_UNTERDECKUNG`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`ZAEHLEINRICHTUNG`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`WANDLER_MENGENUMWERTER`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`KOMMUNIKATIONSEINRICHTUNG`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`TECHNISCHE_STEUEREINRICHTUNG`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`PARAGRAF_19_STROM_NEV_UMLAGE`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`BEFESTIGUNGSEINRICHTUNG`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`OFFSHORE_HAFTUNGSUMLAGE`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`FIXE_ARBEITSENTGELTKOMPONENTE`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`FIXE_LEISTUNGSENTGELTKOMPONENTE`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`UMLAGE_ABSCHALTBARE_LASTEN`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`MEHRMENGE`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`MINDERMENGE`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`ENERGIESTEUER`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`SMARTMETER_GATEWAY`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`STEUERBOX`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`MSB_INKL_MESSUNG`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`ZUSATZDIENSTLEISTUNG_PARAGRAPH_35_2_1_MSBG`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`ZUSATZDIENSTLEISTUNG_PARAGRAPH_35_2_2_MSBG`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`ZUSATZDIENSTLEISTUNG_PARAGRAPH_35_2_3_MSBG`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`ZUSATZDIENSTLEISTUNG_PARAGRAPH_35_2_4_MSBG`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`ZUSATZDIENSTLEISTUNG_PARAGRAPH_35_2_5_MSBG`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`ZUSATZDIENSTLEISTUNG_PARAGRAPH_35_3_MSBG`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e4">`ENTGELT_KAPAZITAETEN`</span> | — | — | Must | — |
| <span className="hbs-f hbs-e3">[freitext](/en/bo4e/202610/com/Angebotsposition#freitext)</span> <AhbTabelle pruefid="15001" format="QUOTES" fv="202610" zeile={77} segment="SG27.LIN.FTX+ACB" /><span className="hbs-nr">00060</span> | Additional information (for general notes) | string | X | — |
| <span className="hbs-f hbs-e3">[positionsbezeichnung](/en/bo4e/202610/com/Angebotsposition#positionsbezeichnung) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="15001" format="QUOTES" fv="202610" zeile={58} segment="SG27.LIN" /><span className="hbs-nr">00070</span> | Designation of the line item | string | Must | — |
| <span className="hbs-g hbs-e3">**beteiligterMarktpartner**</span> | — | object | May | — |
| <span className="hbs-f hbs-e4">[rollencodenummer](/en/bo4e/202610/bo/Marktteilnehmer#rollencodenummer)</span> <AhbTabelle pruefid="15001" format="QUOTES" fv="202610" zeile={208} segment="SG27.LIN.SG42.NAD+VY" /><span className="hbs-nr">00080</span> | Specifies the code value of the market role. | string | X | — |
| <span className="hbs-f hbs-e4">[rollencodetyp](/en/bo4e/202610/bo/Marktteilnehmer#rollencodetyp)</span> <AhbTabelle pruefid="15001" format="QUOTES" fv="202610" zeile={208} segment="SG27.LIN.SG42.NAD+VY" /><span className="hbs-nr">00090</span> | Indicates the type of the code. | [Enum Rollencodetyp](/en/bo4e/202610/enum/Rollencodetyp) | X | — |
| <span className="hbs-w hbs-e5">`BDEW`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`GS1`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`GLN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`DVGW`</span> | — | — | X | — |
| <span className="hbs-g hbs-e3">**positionspreis** <span className="hbs-liste">[ ]</span></span> | — | object[] | May | — |
| <span className="hbs-f hbs-e4">[bezugswert](/en/bo4e/202610/com/Preis#bezugswert)</span> <AhbTabelle pruefid="15001" format="QUOTES" fv="202610" zeile={194} segment="SG27.LIN.SG31.PRI+CAL" /><span className="hbs-nr">00100</span> | Unit: measurands that can be determined by measurement or by specification | [Enum Mengeneinheit](/en/bo4e/202610/enum/Mengeneinheit) | X | — |
| <span className="hbs-w hbs-e5">`W`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`WH`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`KW`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`KWH`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`KVARH`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`MW`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`MWH`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`STUECK`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`KUBIKMETER`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`STUNDE`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`TAG`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`MONAT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`JAHR`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`PROZENT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`ANZAHL`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`VAR`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`KVAR`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`VARH`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`KWHK`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`Z16`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`KWT`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`WATT_PRO_QUADRATMETER`</span> | — | — | X | — |
| <span className="hbs-w hbs-e5">`METER_PRO_SEKUNDE`</span> | — | — | X | — |
| <span className="hbs-f hbs-e4">[menge](/en/bo4e/202610/com/Preis#menge)</span> <AhbTabelle pruefid="15001" format="QUOTES" fv="202610" zeile={194} segment="SG27.LIN.SG31.PRI+CAL" /><span className="hbs-nr">00110</span> | menge | integer | X | — |
| <span className="hbs-f hbs-e4">[wert](/en/bo4e/202610/com/Preis#wert)</span> <AhbTabelle pruefid="15001" format="QUOTES" fv="202610" zeile={194} segment="SG27.LIN.SG31.PRI+CAL" /><span className="hbs-nr">00120</span> | wert | number (float) | X | — |
| <span className="hbs-g hbs-e3">**verweisKatalognummer**</span> | — | object | May | — |
| <span className="hbs-f hbs-e4">[katalognummer](/en/bo4e/202610/com/Katalogverweis#katalognummer)</span> <AhbTabelle pruefid="15001" format="QUOTES" fv="202610" zeile={203} segment="SG27.LIN.SG32.RFF+APF" /><span className="hbs-nr">00130</span> | Catalog number | string | X | — |
| <span className="hbs-f hbs-e4">[versionsnummer](/en/bo4e/202610/com/Katalogverweis#versionsnummer)</span> <AhbTabelle pruefid="15001" format="QUOTES" fv="202610" zeile={203} segment="SG27.LIN.SG32.RFF+APF" /><span className="hbs-nr">00140</span> | Version number | string | X | — |
| <span className="hbs-f hbs-e4">[zeilennummer](/en/bo4e/202610/com/Katalogverweis#zeilennummer)</span> <AhbTabelle pruefid="15001" format="QUOTES" fv="202610" zeile={203} segment="SG27.LIN.SG32.RFF+APF" /><span className="hbs-nr">00150</span> | Line number | string | X | — |
| <span className="hbs-g hbs-e1">**MESSLOKATION** <span className="hbs-liste">[ ]</span> <span className="hbs-pflicht">\*</span></span> | — | object[] | Must | — |
| <span className="hbs-f hbs-e2">[messlokationsId](/en/bo4e/202610/bo/Messlokation#messlokationsid) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="15001" format="QUOTES" fv="202610" zeile={56} segment="SG11.NAD+DP.LOC+172" /><span className="hbs-nr">00160</span> | The metering location identification. This is the former metering point identifier,<br/>e.g. DE 47108151234567 | string | X | — |
| <span className="hbs-g hbs-e1">**ZAEHLER** <span className="hbs-liste">[ ]</span></span> | — | object[] | May | — |
| <span className="hbs-f hbs-e2">[befestigungsart](/en/bo4e/202610/bo/Zaehler#befestigungsart)</span> <AhbTabelle pruefid="15001" format="QUOTES" fv="202610" zeile={81} segment="SG27.LIN.SG28.CCI+Z28.CAV" /><span className="hbs-nr">00170</span> | Mounting type | [Enum Befestigungsart](/en/bo4e/202610/enum/Befestigungsart) | Must | — |
| <span className="hbs-w hbs-e3">`STECKTECHNIK`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`DREIPUNKT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`HUTSCHIENE`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`EINSTUTZEN`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`ZWEISTUTZEN`</span> | — | — | Must | — |
| <span className="hbs-f hbs-e2">[eichungBis](/en/bo4e/202610/bo/Zaehler#eichungbis)</span> <AhbTabelle pruefid="15001" format="QUOTES" fv="202610" zeile={69} segment="SG27.LIN.DTM+Z04" /><span className="hbs-nr">00180</span> | The meter is calibrated up to this date. | string | X | — |
| <span className="hbs-f hbs-e2">[messwerterfassung](/en/bo4e/202610/bo/Zaehler#messwerterfassung)</span> <AhbTabelle pruefid="15001" format="QUOTES" fv="202610" zeile={81} segment="SG27.LIN.SG28.CCI+E12.CAV" /><span className="hbs-nr">00190</span> | Meter reading capture at the metering point | [Enum Messwerterfassung](/en/bo4e/202610/enum/Messwerterfassung) | Must | — |
| <span className="hbs-w hbs-e3">`FERNAUSLESBAR`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`MANUELL_AUSGELESENE`</span> | — | — | Must | — |
| <span className="hbs-f hbs-e2">[tarifart](/en/bo4e/202610/bo/Zaehler#tarifart)</span> <AhbTabelle pruefid="15001" format="QUOTES" fv="202610" zeile={81} segment="SG27.LIN.SG28.CCI+E13.CAV" /><span className="hbs-nr">00200</span> | Specification regarding supported tariff types. | [Enum Tarifart](/en/bo4e/202610/enum/Tarifart) | Must | — |
| <span className="hbs-w hbs-e3">`EINTARIF`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`ZWEITARIF`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`MEHRTARIF`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`SMART_METER`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`LEISTUNGSGEMESSEN`</span> | — | — | Must | — |
| <span className="hbs-f hbs-e2">[zaehlerauspraegung](/en/bo4e/202610/bo/Zaehler#zaehlerauspraegung)</span> <AhbTabelle pruefid="15001" format="QUOTES" fv="202610" zeile={81} segment="SG27.LIN.SG28.CCI+E13.CAV" /><span className="hbs-nr">00210</span> | Specification regarding the direction of the meter. | [Enum Zaehlerauspraegung](/en/bo4e/202610/enum/Zaehlerauspraegung) | Must | — |
| <span className="hbs-w hbs-e3">`EINRICHTUNGSZAEHLER`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`ZWEIRICHTUNGSZAEHLER`</span> | — | — | Must | — |
| <span className="hbs-f hbs-e2">[zaehlergroesse](/en/bo4e/202610/bo/Zaehler#zaehlergroesse)</span> <AhbTabelle pruefid="15001" format="QUOTES" fv="202610" zeile={81} segment="SG27.LIN.SG28.CCI+E13.CAV" /><span className="hbs-nr">00220</span> | Meter size | [Enum Geraetemerkmal](/en/bo4e/202610/enum/Geraetemerkmal) | Must | — |
| <span className="hbs-w hbs-e3">`EINTARIF`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`ZWEITARIF`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`MEHRTARIF`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`GAS_G2P5`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`GAS_G4`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`GAS_G6`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`GAS_G10`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`GAS_G16`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`GAS_G25`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`GAS_G40`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`GAS_G65`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`GAS_G100`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`GAS_G160`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`GAS_G250`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`GAS_G350`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`GAS_G400`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`GAS_G4000`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`GAS_G650`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`GAS_G6500`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`GAS_G1000`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`GAS_G10000`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`GAS_G12500`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`GAS_G1600`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`GAS_G16000`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`GAS_G2500`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`IMPULSGEBER_G4_G100`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`IMPULSGEBER_G100`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`MODEM_GSM`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`MODEM_GPRS`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`MODEM_FUNK`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`MODEM_GSM_O_LG`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`MODEM_GSM_M_LG`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`MODEM_FESTNETZ`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`MODEM_GPRS_M_LG`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`PLC_COM`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`ETHERNET_KOM`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`DSL_KOM`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`LTE_KOM`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`RUNDSTEUEREMPFAENGER`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`TARIFSCHALTGERAET`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`ZUSTANDS_MU`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`TEMPERATUR_MU`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`KOMPAKT_MU`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`SYSTEM_MU`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`UNBESTIMMT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`WASSER_MWZW`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`WASSER_WZWW`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`WASSER_WZ01`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`WASSER_WZ02`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`WASSER_WZ03`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`WASSER_WZ04`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`WASSER_WZ05`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`WASSER_WZ06`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`WASSER_WZ07`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`WASSER_WZ08`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`WASSER_WZ09`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`WASSER_WZ10`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`WASSER_VWZ04`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`WASSER_VWZ05`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`WASSER_VWZ06`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`WASSER_VWZ07`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`WASSER_VWZ10`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`DICHTEMENGENUMWERTER`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`TEMPERATURMENGENUMWERTER`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`ZUSTANDSMENGENUMWERTER`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`BLOCKSTROMWANDLER`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`MESSWANDLERSATZ_IMS_MME`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`KOMBIMESSWANDLER`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`SPANNUNGSWANDLER`</span> | — | — | Must | — |
| <span className="hbs-f hbs-e2">[zaehlertyp](/en/bo4e/202610/bo/Zaehler#zaehlertyp)</span> <AhbTabelle pruefid="15001" format="QUOTES" fv="202610" zeile={81} segment="SG27.LIN.SG28.CCI+E13.CAV" /><span className="hbs-nr">00230</span> | Typing of the meter | [Enum Zaehlertyp](/en/bo4e/202610/enum/Zaehlertyp) | Must | — |
| <span className="hbs-w hbs-e3">`DREHSTROMZAEHLER`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`BALGENGASZAEHLER`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`DREHKOLBENZAEHLER`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`SMARTMETER`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`LEISTUNGSZAEHLER`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`MAXIMUMZAEHLER`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`TURBINENRADGASZAEHLER`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`ULTRASCHALLGASZAEHLER`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`WECHSELSTROMZAEHLER`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`WIRBELGASZAEHLER`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`MESSDATENREGISTRIERGERAET`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`ELEKTRONISCHERHAUSHALTSZAEHLER`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`SONDERAUSSTATTUNG`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`WASSERZAEHLER`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`MODERNEMESSEINRICHTUNG`</span> | — | — | Must | — |
| <span className="hbs-f hbs-e2">[zaehlertypspezifikation](/en/bo4e/202610/bo/Zaehler#zaehlertypspezifikation)</span> <AhbTabelle pruefid="15001" format="QUOTES" fv="202610" zeile={81} segment="SG27.LIN.SG28.CCI+E13.CAV" /><span className="hbs-nr">00240</span> | Typing of the meter (specification for EHZ and MME) | [Enum ZaehlertypSpezifikation](/en/bo4e/202610/enum/ZaehlertypSpezifikation) | Must | — |
| <span className="hbs-w hbs-e3">`EDL40`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`EDL21`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`SONSTIGER_EHZ`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`MME_STANDARD`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`MME_MEDA`</span> | — | — | Must | — |
| <span className="hbs-g hbs-e2">**geraete** <span className="hbs-liste">[ ]</span></span> | — | object[] | May | — |
| <span className="hbs-g hbs-e3">**geraeteeigenschaften**</span> | — | object | May | — |
| <span className="hbs-f hbs-e4">[faktor](/en/bo4e/202610/com/Geraeteeigenschaften#faktor)</span> <AhbTabelle pruefid="15001" format="QUOTES" fv="202610" zeile={81} segment="SG27.LIN.SG28.CCI+Z25.CAV" /><span className="hbs-nr">00250</span> | faktor | number (float) | Must | — |
| <span className="hbs-f hbs-e4">[firmwareVersion](/en/bo4e/202610/com/Geraeteeigenschaften#firmwareversion)</span> <AhbTabelle pruefid="15001" format="QUOTES" fv="202610" zeile={81} segment="SG27.LIN.SG28.CCI+Z75.CAV" /><span className="hbs-nr">00260</span> | Firmware version | string | Must | — |
| <span className="hbs-f hbs-e4">[geraetemerkmal](/en/bo4e/202610/com/Geraeteeigenschaften#geraetemerkmal)</span> <AhbTabelle pruefid="15001" format="QUOTES" fv="202610" zeile={81} segment="SG27.LIN.SG28.CCI+Z25.CAV" /><span className="hbs-nr">00270</span> | Geraetemerkmal | [Enum Geraetemerkmal](/en/bo4e/202610/enum/Geraetemerkmal) | Must | — |
| <span className="hbs-w hbs-e5">`EINTARIF`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`ZWEITARIF`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`MEHRTARIF`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`GAS_G2P5`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`GAS_G4`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`GAS_G6`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`GAS_G10`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`GAS_G16`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`GAS_G25`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`GAS_G40`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`GAS_G65`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`GAS_G100`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`GAS_G160`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`GAS_G250`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`GAS_G350`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`GAS_G400`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`GAS_G4000`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`GAS_G650`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`GAS_G6500`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`GAS_G1000`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`GAS_G10000`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`GAS_G12500`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`GAS_G1600`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`GAS_G16000`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`GAS_G2500`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`IMPULSGEBER_G4_G100`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`IMPULSGEBER_G100`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`MODEM_GSM`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`MODEM_GPRS`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`MODEM_FUNK`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`MODEM_GSM_O_LG`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`MODEM_GSM_M_LG`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`MODEM_FESTNETZ`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`MODEM_GPRS_M_LG`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`PLC_COM`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`ETHERNET_KOM`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`DSL_KOM`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`LTE_KOM`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`RUNDSTEUEREMPFAENGER`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`TARIFSCHALTGERAET`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`ZUSTANDS_MU`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`TEMPERATUR_MU`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`KOMPAKT_MU`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`SYSTEM_MU`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`UNBESTIMMT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`WASSER_MWZW`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`WASSER_WZWW`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`WASSER_WZ01`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`WASSER_WZ02`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`WASSER_WZ03`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`WASSER_WZ04`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`WASSER_WZ05`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`WASSER_WZ06`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`WASSER_WZ07`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`WASSER_WZ08`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`WASSER_WZ09`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`WASSER_WZ10`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`WASSER_VWZ04`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`WASSER_VWZ05`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`WASSER_VWZ06`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`WASSER_VWZ07`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`WASSER_VWZ10`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`DICHTEMENGENUMWERTER`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`TEMPERATURMENGENUMWERTER`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`ZUSTANDSMENGENUMWERTER`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`BLOCKSTROMWANDLER`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`MESSWANDLERSATZ_IMS_MME`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`KOMBIMESSWANDLER`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`SPANNUNGSWANDLER`</span> | — | — | Must | — |
| <span className="hbs-f hbs-e4">[herstellerTypbezeichnung](/en/bo4e/202610/com/Geraeteeigenschaften#herstellertypbezeichnung)</span> <AhbTabelle pruefid="15001" format="QUOTES" fv="202610" zeile={81} segment="SG27.LIN.SG28.CCI+Z75.CAV" /><span className="hbs-nr">00280</span> | Manufacturer type designation | string | Must | — |
| <span className="hbs-f hbs-e4">[ipVersion](/en/bo4e/202610/com/Geraeteeigenschaften#ipversion)</span> <AhbTabelle pruefid="15001" format="QUOTES" fv="202610" zeile={81} segment="SG27.LIN.SG28.CCI+Z75.CAV" /><span className="hbs-nr">00290</span> | IP version | string | Must | — |
| <span className="hbs-f hbs-e4">[modemKennungIMSI](/en/bo4e/202610/com/Geraeteeigenschaften#modemkennungimsi)</span> <AhbTabelle pruefid="15001" format="QUOTES" fv="202610" zeile={81} segment="SG27.LIN.SG28.CCI+Z75.CAV" /><span className="hbs-nr">00300</span> | Modem identifier (IMSI) | string | Must | — |
| <span className="hbs-f hbs-e4">[simKartenNummer](/en/bo4e/202610/com/Geraeteeigenschaften#simkartennummer)</span> <AhbTabelle pruefid="15001" format="QUOTES" fv="202610" zeile={81} segment="SG27.LIN.SG28.CCI+Z75.CAV" /><span className="hbs-nr">00310</span> | SIM card number | string | Must | — |
| <span className="hbs-f hbs-e4">[tkProvider](/en/bo4e/202610/com/Geraeteeigenschaften#tkprovider)</span> <AhbTabelle pruefid="15001" format="QUOTES" fv="202610" zeile={81} segment="SG27.LIN.SG28.CCI+Z75.CAV" /><span className="hbs-nr">00320</span> | Telecommunications provider | string | Must | — |
| <span className="hbs-g hbs-e0">**transaktionsdaten** <span className="hbs-pflicht">\*</span></span> | — | object | Must | — |
| <span className="hbs-f hbs-e1">[dokumentennummer](/en/bo4e/202610/cdoc/Transaktionsdaten#dokumentennummer) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="15001" format="QUOTES" fv="202610" zeile={8} segment="BGM+310" /><span className="hbs-nr">00330</span> | EDIFACT reference from the BGM segment / BGM | string | X | — |
| <span className="hbs-f hbs-e1">[kategorie](/en/bo4e/202610/cdoc/Transaktionsdaten#kategorie) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="15001" format="QUOTES" fv="202610" zeile={8} segment="BGM+310" /><span className="hbs-nr">00340</span> | Qualifier from the beginning of the EDIFACT message / BGM | string | X | — |
| <span className="hbs-f hbs-e1">[nachrichtendatum](/en/bo4e/202610/cdoc/Transaktionsdaten#nachrichtendatum) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="15001" format="QUOTES" fv="202610" zeile={11} segment="DTM+137" /><span className="hbs-nr">00350</span> | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| <span className="hbs-f hbs-e1">[nachrichtenreferenznummer](/en/bo4e/202610/cdoc/Transaktionsdaten#nachrichtenreferenznummer) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="15001" format="QUOTES" fv="202610" zeile={0} segment="UNH" /><span className="hbs-nr">00360</span> | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| <span className="hbs-f hbs-e1">[pruefidentifikator](/en/bo4e/202610/cdoc/Transaktionsdaten#pruefidentifikator) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="15001" format="QUOTES" fv="202610" zeile={25} segment="SG1.RFF+Z13" /><span className="hbs-nr">00370</span> | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| <span className="hbs-g hbs-e1">**absender** <span className="hbs-pflicht">\*</span></span> | — | object | Must | — |
| <span className="hbs-f hbs-e2">[rollencodenummer](/en/bo4e/202610/bo/Marktteilnehmer#rollencodenummer) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="15001" format="QUOTES" fv="202610" zeile={32} segment="SG11.NAD+MS" /><span className="hbs-nr">00380</span> | Specifies the code value of the market role. | string | X | — |
| <span className="hbs-f hbs-e2">[rollencodetyp](/en/bo4e/202610/bo/Marktteilnehmer#rollencodetyp) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="15001" format="QUOTES" fv="202610" zeile={32} segment="SG11.NAD+MS" /><span className="hbs-nr">00390</span> | Indicates the type of the code. | [Enum Rollencodetyp](/en/bo4e/202610/enum/Rollencodetyp) | X | — |
| <span className="hbs-w hbs-e3">`BDEW`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`GS1`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`GLN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`DVGW`</span> | — | — | X | — |
| <span className="hbs-g hbs-e2">**ansprechpartner** <span className="hbs-pflicht">\*</span></span> | — | object | Must | — |
| <span className="hbs-f hbs-e3">[eMailAdresse](/en/bo4e/202610/bo/Ansprechpartner#emailadresse)</span> <AhbTabelle pruefid="15001" format="QUOTES" fv="202610" zeile={40} segment="SG11.NAD+MS.SG14.CTA.COM+[EM\|FX\|TE\|AJ\|AL]" /><span className="hbs-nr">00400</span> | Email address | string | Must | — |
| <span className="hbs-f hbs-e3">[nachname](/en/bo4e/202610/bo/Ansprechpartner#nachname) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="15001" format="QUOTES" fv="202610" zeile={37} segment="SG11.NAD+MS.SG14.CTA" /><span className="hbs-nr">00410</span> | Surname (family name) of the contact person | string | Must | — |
| <span className="hbs-g hbs-e3">**rufnummern** <span className="hbs-liste">[ ]</span></span> | — | object[] | May | — |
| <span className="hbs-f hbs-e4">[nummerntyp](/en/bo4e/202610/com/Rufnummer#nummerntyp)</span> <AhbTabelle pruefid="15001" format="QUOTES" fv="202610" zeile={40} segment="SG11.NAD+MS.SG14.CTA.COM+[EM\|FX\|TE\|AJ\|AL]" /><span className="hbs-nr">00420</span> | Phone number type | [Enum Rufnummernart](/en/bo4e/202610/enum/Rufnummernart) | Must | — |
| <span className="hbs-w hbs-e5">`RUF_ZENTRALE`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`FAX_ZENTRALE`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`SAMMELRUF`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`SAMMELFAX`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`ABTEILUNGRUF`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`ABTEILUNGFAX`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`RUF_DURCHWAHL`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`FAX_DURCHWAHL`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e5">`MOBIL_NUMMER`</span> | — | — | Must | — |
| <span className="hbs-f hbs-e4">[rufnummer](/en/bo4e/202610/com/Rufnummer#rufnummer)</span> <AhbTabelle pruefid="15001" format="QUOTES" fv="202610" zeile={40} segment="SG11.NAD+MS.SG14.CTA.COM+[EM\|FX\|TE\|AJ\|AL]" /><span className="hbs-nr">00430</span> | rufnummer | string | Must | — |
| <span className="hbs-g hbs-e1">**empfaenger** <span className="hbs-pflicht">\*</span></span> | — | object | Must | — |
| <span className="hbs-f hbs-e2">[rollencodenummer](/en/bo4e/202610/bo/Marktteilnehmer#rollencodenummer) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="15001" format="QUOTES" fv="202610" zeile={48} segment="SG11.NAD+MR" /><span className="hbs-nr">00440</span> | Specifies the code value of the market role. | string | X | — |
| <span className="hbs-f hbs-e2">[rollencodetyp](/en/bo4e/202610/bo/Marktteilnehmer#rollencodetyp) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="15001" format="QUOTES" fv="202610" zeile={48} segment="SG11.NAD+MR" /><span className="hbs-nr">00450</span> | Indicates the type of the code. | [Enum Rollencodetyp](/en/bo4e/202610/enum/Rollencodetyp) | X | — |
| <span className="hbs-w hbs-e3">`BDEW`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`GS1`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`GLN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`DVGW`</span> | — | — | X | — |

</div>

</Handbuchsatz>

## Application handbook (AHB)

<Handbuchsatz>

<div className="maco-tabellenrahmen" data-maco="ahb-tabelle">

| Structure (EDIFACT) | Description | Format | <span className="hbs-p" title="Angebot Geräteübernahme">15001</span> | Condition |
|---|---|---|---|---|
| <span className="hbs-g hbs-e0">**UNH**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`0062`</span><span className="hbs-nr">00010</span> | Message reference number | — | X | — |
| <span className="hbs-f hbs-e1">`0065 QUOTES`</span><span className="hbs-nr">00020</span> | Quotation | — | X | — |
| <span className="hbs-f hbs-e1">`0052 D`</span><span className="hbs-nr">00030</span> | Draft version | — | X | — |
| <span className="hbs-f hbs-e1">`0054 10A`</span><span className="hbs-nr">00040</span> | Edition 2010 - A | — | X | — |
| <span className="hbs-f hbs-e1">`0051 UN`</span><span className="hbs-nr">00050</span> | UN/CEFACT | — | X | — |
| <span className="hbs-f hbs-e1">`0057 1.3c`</span><span className="hbs-nr">00060</span> | Version number of the underlying BDEW message description | — | X | — |
| <span className="hbs-g hbs-e0">**BGM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1001 310`</span><span className="hbs-nr">00070</span> | Quotation | — | X | — |
| <span className="hbs-f hbs-e1">`1004`</span><span className="hbs-nr">00080</span> | Document number | — | X | — |
| <span className="hbs-g hbs-e0">**DTM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`2005 137`</span><span className="hbs-nr">00090</span> | Document-/message date/time | — | X | — |
| <span className="hbs-f hbs-e1">`2380`</span><span className="hbs-nr">00100</span> | Date or time or time span, value | — | X | <span className="hbs-marke">[931]</span> <span className="hbs-marke">[494]</span> |
| <span className="hbs-f hbs-e1">`2379 303`</span><span className="hbs-nr">00110</span> | CCYYMMDDHHMMZZZ | — | X | — |
| <span className="hbs-g hbs-e0">**DTM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`2005 76`</span><span className="hbs-nr">00120</span> | Delivery date/time, scheduled | — | X | — |
| <span className="hbs-f hbs-e1">`2380`</span><span className="hbs-nr">00130</span> | Date or time or time span, value | — | X | <span className="hbs-marke">[UB3]</span> |
| <span className="hbs-f hbs-e1">`2379 303`</span><span className="hbs-nr">00140</span> | CCYYMMDDHHMMZZZ | — | X | — |
| <span className="hbs-g hbs-e0">**IMD**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7081 Z07`</span><span className="hbs-nr">00150</span> | Purchase | — | X | — |
| <span className="hbs-f hbs-e1">`7081 Z08`</span><span className="hbs-nr">00160</span> | Transfer of use | — | X | — |
| <span className="hbs-g hbs-e0">**SG1.RFF**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1153 AAV`</span><span className="hbs-nr">00170</span> | Number of the request | — | X | — |
| <span className="hbs-f hbs-e1">`1154`</span><span className="hbs-nr">00180</span> | Message number | — | X | <span className="hbs-marke">[504]</span> |
| <span className="hbs-g hbs-e0">**SG1.RFF**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1153 Z13`</span><span className="hbs-nr">00190</span> | Check identifier | — | X | — |
| <span className="hbs-f hbs-e1">`1154 15001`</span><span className="hbs-nr">00200</span> | Quotation for device takeover | — | X | — |
| <span className="hbs-g hbs-e0">**SG4.CUX**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`6347 2`</span><span className="hbs-nr">00210</span> | Reference currency | — | X | — |
| <span className="hbs-f hbs-e1">`6345 EUR`</span><span className="hbs-nr">00220</span> | Euro | — | X | — |
| <span className="hbs-f hbs-e1">`6343 4`</span><span className="hbs-nr">00230</span> | Currency of the invoice | — | X | — |
| <span className="hbs-g hbs-e0">**SG11.NAD**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3035 MS`</span><span className="hbs-nr">00240</span> | Document-/message sender or sender | — | X | — |
| <span className="hbs-f hbs-e1">`3039`</span><span className="hbs-nr">00250</span> | MP-ID | — | X | — |
| <span className="hbs-f hbs-e1">`3055 9`</span><span className="hbs-nr">00260</span> | GS1 | — | X | — |
| <span className="hbs-f hbs-e1">`3055 293`</span><span className="hbs-nr">00270</span> | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| <span className="hbs-f hbs-e1">`3055 332`</span><span className="hbs-nr">00280</span> | DE, DVGW Service & Consult GmbH | — | X | — |
| <span className="hbs-g hbs-e0">**SG14.CTA**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3139 IC`</span><span className="hbs-nr">00290</span> | Information contact | — | X | — |
| <span className="hbs-f hbs-e1">`3412`</span><span className="hbs-nr">00300</span> | Contact | — | X | <span className="hbs-marke">[500]</span> |
| <span className="hbs-g hbs-e0">**SG14.COM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3148`</span><span className="hbs-nr">00310</span> | Communication address, identification | — | X | ((<span className="hbs-marke">[939]</span> <span className="hbs-marke">[72]</span>) ⊻ (<span className="hbs-marke">[940]</span> <span className="hbs-marke">[73]</span>)) ∧ <span className="hbs-marke">[516]</span> |
| <span className="hbs-f hbs-e1">`3155 EM`</span><span className="hbs-nr">00320</span> | Electronic mail | — | X | <span className="hbs-marke">[1P0..1]</span> |
| <span className="hbs-f hbs-e1">`3155 FX`</span><span className="hbs-nr">00330</span> | Fax number | — | X | <span className="hbs-marke">[1P0..1]</span> |
| <span className="hbs-f hbs-e1">`3155 TE`</span><span className="hbs-nr">00340</span> | Telephone | — | X | <span className="hbs-marke">[1P0..1]</span> |
| <span className="hbs-f hbs-e1">`3155 AJ`</span><span className="hbs-nr">00350</span> | further telephone | — | X | <span className="hbs-marke">[1P0..1]</span> |
| <span className="hbs-f hbs-e1">`3155 AL`</span><span className="hbs-nr">00360</span> | Mobile phone | — | X | <span className="hbs-marke">[1P0..1]</span> |
| <span className="hbs-g hbs-e0">**SG11.NAD**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3035 MR`</span><span className="hbs-nr">00370</span> | Message recipient | — | X | — |
| <span className="hbs-f hbs-e1">`3039`</span><span className="hbs-nr">00380</span> | MP-ID | — | X | — |
| <span className="hbs-f hbs-e1">`3055 9`</span><span className="hbs-nr">00390</span> | GS1 | — | X | — |
| <span className="hbs-f hbs-e1">`3055 293`</span><span className="hbs-nr">00400</span> | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| <span className="hbs-f hbs-e1">`3055 332`</span><span className="hbs-nr">00410</span> | DE, DVGW Service & Consult GmbH | — | X | — |
| <span className="hbs-g hbs-e0">**SG11.NAD**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3035 DP`</span><span className="hbs-nr">00420</span> | Supply address | — | X | — |
| <span className="hbs-g hbs-e0">**SG11.LOC**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3227 172`</span><span className="hbs-nr">00430</span> | Reporting point | — | X | — |
| <span className="hbs-f hbs-e1">`3225`</span><span className="hbs-nr">00440</span> | Identifier | — | X | <span className="hbs-marke">[951]</span> <span className="hbs-marke">[502]</span> |
| <span className="hbs-g hbs-e0">**SG27.LIN**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1082`</span><span className="hbs-nr">00450</span> | Line item number | — | X | <span className="hbs-marke">[911]</span> |
| <span className="hbs-f hbs-e1">`7140`</span><span className="hbs-nr">00460</span> | Product/service number | — | X | <span className="hbs-marke">[31]</span> |
| <span className="hbs-f hbs-e1">`7143 Z01`</span><span className="hbs-nr">00470</span> | Article number | — | X | — |
| <span className="hbs-g hbs-e0">**SG27.IMD**</span> | — | — | Should | <span className="hbs-marke">[1]</span> |
| <span className="hbs-f hbs-e1">`7081 Z09`</span><span className="hbs-nr">00480</span> | Cannot be offered | — | X | — |
| <span className="hbs-g hbs-e0">**SG27.DTM**</span> | — | — | Must | <span className="hbs-marke">[2]</span> |
| <span className="hbs-f hbs-e1">`2005 94`</span><span className="hbs-nr">00490</span> | Production/manufacturing date | — | X | — |
| <span className="hbs-f hbs-e1">`2005 Z03`</span><span className="hbs-nr">00500</span> | Year of manufacture / year of placing on the market | — | X | — |
| <span className="hbs-f hbs-e1">`2380`</span><span className="hbs-nr">00510</span> | Date or time or time span, value | — | X | — |
| <span className="hbs-f hbs-e1">`2379 602`</span><span className="hbs-nr">00520</span> | CCYY | — | X | — |
| <span className="hbs-g hbs-e0">**SG27.DTM**</span> | — | — | Must | <span className="hbs-marke">[2]</span> ∧ (<span className="hbs-marke">[5]</span> ⊻ <span className="hbs-marke">[3]</span> ⊻ <span className="hbs-marke">[22]</span>) |
| <span className="hbs-f hbs-e1">`2005 Z04`</span><span className="hbs-nr">00530</span> | Calibration validity | — | X | — |
| <span className="hbs-f hbs-e1">`2380`</span><span className="hbs-nr">00540</span> | Date or time or time span, value | — | X | — |
| <span className="hbs-f hbs-e1">`2379 602`</span><span className="hbs-nr">00550</span> | CCYY | — | X | — |
| <span className="hbs-g hbs-e0">**SG27.GIN**</span> | — | — | Should | <span className="hbs-marke">[2]</span> ∧ <span className="hbs-marke">[4]</span> |
| <span className="hbs-f hbs-e1">`7405 BN`</span><span className="hbs-nr">00560</span> | Serial number | — | X | — |
| <span className="hbs-f hbs-e1">`7402`</span><span className="hbs-nr">00570</span> | Manufacturer number | — | X | — |
| <span className="hbs-g hbs-e0">**SG27.FTX**</span> | — | — | May | — |
| <span className="hbs-f hbs-e1">`4451 ACB`</span><span className="hbs-nr">00580</span> | Additional information (for general notes) | — | X | — |
| <span className="hbs-f hbs-e1">`4440`</span><span className="hbs-nr">00590</span> | Free text | — | X | — |
| <span className="hbs-g hbs-e0">**SG28.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7037 E13`</span><span className="hbs-nr">00600</span> | Meter type | — | X | — |
| <span className="hbs-g hbs-e0">**SG28.CAV**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7111 AHZ`</span><span className="hbs-nr">00610</span> | analog household meter (three-phase current) | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`7111 BGZ`</span><span className="hbs-nr">00620</span> | Diaphragm gas meter | — | X | <span className="hbs-marke">[5P0..1]</span> |
| <span className="hbs-f hbs-e1">`7111 DKZ`</span><span className="hbs-nr">00630</span> | Rotary piston gas meter | — | X | <span className="hbs-marke">[5P0..1]</span> |
| <span className="hbs-f hbs-e1">`7111 EHZ`</span><span className="hbs-nr">00640</span> | electronic household meter | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[5P0..1]</span> |
| <span className="hbs-f hbs-e1">`7111 IVA`</span><span className="hbs-nr">00650</span> | Individual reconciliation (special equipment) | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[5P0..1]</span> |
| <span className="hbs-f hbs-e1">`7111 LAZ`</span><span className="hbs-nr">00660</span> | Load curve meter | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`7111 MAZ`</span><span className="hbs-nr">00670</span> | Maximum demand meter | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`7111 MME`</span><span className="hbs-nr">00680</span> | modern metering device according to MsbG | — | X | <span className="hbs-marke">[4P0..1]</span> ⊻ <span className="hbs-marke">[5P0..1]</span> |
| <span className="hbs-f hbs-e1">`7111 MRG`</span><span className="hbs-nr">00690</span> | Measurement data recording device | — | X | <span className="hbs-marke">[5P0..1]</span> |
| <span className="hbs-f hbs-e1">`7111 TRZ`</span><span className="hbs-nr">00700</span> | Turbine gas meter | — | X | <span className="hbs-marke">[5P0..1]</span> |
| <span className="hbs-f hbs-e1">`7111 UGZ`</span><span className="hbs-nr">00710</span> | Ultrasonic gas meter | — | X | <span className="hbs-marke">[5P0..1]</span> |
| <span className="hbs-f hbs-e1">`7111 WGZ`</span><span className="hbs-nr">00720</span> | Vortex gas meter | — | X | <span className="hbs-marke">[5P0..1]</span> |
| <span className="hbs-f hbs-e1">`7111 WSZ`</span><span className="hbs-nr">00730</span> | analog alternating current meter | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`7110 Z01`</span><span className="hbs-nr">00740</span> | EDL40 | — | X | <span className="hbs-marke">[2P0..1]</span> |
| <span className="hbs-f hbs-e1">`7110 Z02`</span><span className="hbs-nr">00750</span> | EDL21 | — | X | <span className="hbs-marke">[2P0..1]</span> |
| <span className="hbs-f hbs-e1">`7110 Z03`</span><span className="hbs-nr">00760</span> | other EHZ | — | X | <span className="hbs-marke">[2P0..1]</span> |
| <span className="hbs-f hbs-e1">`7110 Z04`</span><span className="hbs-nr">00770</span> | Standard | — | X | <span className="hbs-marke">[3P0..1]</span> |
| <span className="hbs-f hbs-e1">`7110 Z05`</span><span className="hbs-nr">00780</span> | MeDa meter | — | X | <span className="hbs-marke">[3P0..1]</span> |
| <span className="hbs-g hbs-e0">**SG28.CAV**</span> | — | — | Must | <span className="hbs-marke">[493]</span> |
| <span className="hbs-f hbs-e1">`7110 G10`</span><span className="hbs-nr">00790</span> | Gas meter G10 | — | X | — |
| <span className="hbs-f hbs-e1">`7110 G100`</span><span className="hbs-nr">00800</span> | Gas meter G100 | — | X | — |
| <span className="hbs-f hbs-e1">`7110 G1000`</span><span className="hbs-nr">00810</span> | Gas meter G1000 | — | X | — |
| <span className="hbs-f hbs-e1">`7110 G10000`</span><span className="hbs-nr">00820</span> | Gas meter G10000 | — | X | — |
| <span className="hbs-f hbs-e1">`7110 G12500`</span><span className="hbs-nr">00830</span> | Gas meter G12500 | — | X | — |
| <span className="hbs-f hbs-e1">`7110 G16`</span><span className="hbs-nr">00840</span> | Gas meter G16 | — | X | — |
| <span className="hbs-f hbs-e1">`7110 G160`</span><span className="hbs-nr">00850</span> | Gas meter G160 | — | X | — |
| <span className="hbs-f hbs-e1">`7110 G1600`</span><span className="hbs-nr">00860</span> | Gas meter G1600 | — | X | — |
| <span className="hbs-f hbs-e1">`7110 G16000`</span><span className="hbs-nr">00870</span> | Gas meter G16000 | — | X | — |
| <span className="hbs-f hbs-e1">`7110 G2.5`</span><span className="hbs-nr">00880</span> | Gas meter G2.5 | — | X | — |
| <span className="hbs-f hbs-e1">`7110 G25`</span><span className="hbs-nr">00890</span> | Gas meter G25 | — | X | — |
| <span className="hbs-f hbs-e1">`7110 G250`</span><span className="hbs-nr">00900</span> | Gas meter G250 | — | X | — |
| <span className="hbs-f hbs-e1">`7110 G2500`</span><span className="hbs-nr">00910</span> | Gas meter G2500 | — | X | — |
| <span className="hbs-f hbs-e1">`7110 G350`</span><span className="hbs-nr">00920</span> | Gas meter G350 | — | X | — |
| <span className="hbs-f hbs-e1">`7110 G4`</span><span className="hbs-nr">00930</span> | Gas meter G4 | — | X | — |
| <span className="hbs-f hbs-e1">`7110 G40`</span><span className="hbs-nr">00940</span> | Gas meter G40 | — | X | — |
| <span className="hbs-f hbs-e1">`7110 G400`</span><span className="hbs-nr">00950</span> | Gas meter G400 | — | X | — |
| <span className="hbs-f hbs-e1">`7110 G4000`</span><span className="hbs-nr">00960</span> | Gas meter G4000 | — | X | — |
| <span className="hbs-f hbs-e1">`7110 G6`</span><span className="hbs-nr">00970</span> | Gas meter G6 | — | X | — |
| <span className="hbs-f hbs-e1">`7110 G65`</span><span className="hbs-nr">00980</span> | Gas meter G65 | — | X | — |
| <span className="hbs-f hbs-e1">`7110 G650`</span><span className="hbs-nr">00990</span> | Gas meter G650 | — | X | — |
| <span className="hbs-f hbs-e1">`7110 G6500`</span><span className="hbs-nr">01000</span> | Gas meter G6500 | — | X | — |
| <span className="hbs-g hbs-e0">**SG28.CAV**</span> | — | — | Must | <span className="hbs-marke">[492]</span> |
| <span className="hbs-f hbs-e1">`7111 ETZ`</span><span className="hbs-nr">01010</span> | Single tariff | — | X | — |
| <span className="hbs-f hbs-e1">`7111 ZTZ`</span><span className="hbs-nr">01020</span> | Two-tariff | — | X | — |
| <span className="hbs-f hbs-e1">`7111 NTZ`</span><span className="hbs-nr">01030</span> | Multi-tariff | — | X | — |
| <span className="hbs-g hbs-e0">**SG28.CAV**</span> | — | — | Must | <span className="hbs-marke">[492]</span> |
| <span className="hbs-f hbs-e1">`7111 ERZ`</span><span className="hbs-nr">01040</span> | Single-direction meter | — | X | — |
| <span className="hbs-f hbs-e1">`7111 ZRZ`</span><span className="hbs-nr">01050</span> | Bidirectional meter | — | X | — |
| <span className="hbs-g hbs-e0">**SG28.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7037 Z25`</span><span className="hbs-nr">01060</span> | Instrument transformer | — | X | — |
| <span className="hbs-g hbs-e0">**SG28.CAV**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7111 MBW`</span><span className="hbs-nr">01070</span> | Block current transformer | — | X | — |
| <span className="hbs-f hbs-e1">`7111 MIW`</span><span className="hbs-nr">01080</span> | Current transformer set | — | X | — |
| <span className="hbs-f hbs-e1">`7111 MPW`</span><span className="hbs-nr">01090</span> | Combined instrument transformer set (current and voltage) | — | X | — |
| <span className="hbs-f hbs-e1">`7111 MUW`</span><span className="hbs-nr">01100</span> | Voltage transformer set | — | X | — |
| <span className="hbs-f hbs-e1">`7110`</span><span className="hbs-nr">01110</span> | Instrument transformer factor | — | — | M <span className="hbs-marke">[914]</span> <span className="hbs-marke">[10]</span> |
| <span className="hbs-g hbs-e0">**SG28.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7037 Z64`</span><span className="hbs-nr">01120</span> | Volume corrector | — | X | — |
| <span className="hbs-g hbs-e0">**SG28.CAV**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7111 DMU`</span><span className="hbs-nr">01130</span> | Density volume converter | — | X | — |
| <span className="hbs-f hbs-e1">`7111 TMU`</span><span className="hbs-nr">01140</span> | Temperature volume converter | — | X | — |
| <span className="hbs-f hbs-e1">`7111 ZMU`</span><span className="hbs-nr">01150</span> | Volume conversion device | — | X | — |
| <span className="hbs-g hbs-e0">**SG28.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7037 Z26`</span><span className="hbs-nr">01160</span> | Communication device | — | X | — |
| <span className="hbs-g hbs-e0">**SG28.CAV**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7111 GSM`</span><span className="hbs-nr">01170</span> | GSM/GPRS/UMTS comm. dev. | — | X | — |
| <span className="hbs-f hbs-e1">`7111 ETH`</span><span className="hbs-nr">01180</span> | Ethernet comm. dev. LAN/WLAN | — | X | — |
| <span className="hbs-f hbs-e1">`7111 PLC`</span><span className="hbs-nr">01190</span> | PLC comm. device | — | X | — |
| <span className="hbs-f hbs-e1">`7111 PST`</span><span className="hbs-nr">01200</span> | Landline comm. dev. TAE | — | X | — |
| <span className="hbs-f hbs-e1">`7111 DSL`</span><span className="hbs-nr">01210</span> | DSL comm. dev. | — | X | — |
| <span className="hbs-f hbs-e1">`7111 LTE`</span><span className="hbs-nr">01220</span> | LTE comm. dev. | — | X | — |
| <span className="hbs-g hbs-e0">**SG28.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7037 Z27`</span><span className="hbs-nr">01230</span> | Technical control device | — | X | — |
| <span className="hbs-g hbs-e0">**SG28.CAV**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7111 RSU`</span><span className="hbs-nr">01240</span> | Ripple control receiver | — | X | — |
| <span className="hbs-f hbs-e1">`7111 TSU`</span><span className="hbs-nr">01250</span> | Tariff time switch | — | X | — |
| <span className="hbs-g hbs-e0">**SG28.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7037 Z75`</span><span className="hbs-nr">01260</span> | Smart meter gateway | — | X | — |
| <span className="hbs-g hbs-e0">**SG28.CAV**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7111 ZV8`</span><span className="hbs-nr">01270</span> | Firmware version | — | X | — |
| <span className="hbs-f hbs-e1">`7110`</span><span className="hbs-nr">01280</span> | Firmware version | — | X | — |
| <span className="hbs-g hbs-e0">**SG28.CAV**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7111 ZV9`</span><span className="hbs-nr">01290</span> | Manufacturer type designation | — | X | — |
| <span className="hbs-f hbs-e1">`7110`</span><span className="hbs-nr">01300</span> | Manufacturer type designation | — | X | — |
| <span className="hbs-g hbs-e0">**SG28.CAV**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7111 ZW0`</span><span className="hbs-nr">01310</span> | SIM card no. | — | X | — |
| <span className="hbs-f hbs-e1">`7110`</span><span className="hbs-nr">01320</span> | SIM card no. | — | X | — |
| <span className="hbs-g hbs-e0">**SG28.CAV**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7111 ZW1`</span><span className="hbs-nr">01330</span> | Modem identifier IMSI | — | X | — |
| <span className="hbs-f hbs-e1">`7110`</span><span className="hbs-nr">01340</span> | Modem identifier IMSI | — | X | — |
| <span className="hbs-g hbs-e0">**SG28.CAV**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7111 ZW2`</span><span className="hbs-nr">01350</span> | TK provider | — | X | — |
| <span className="hbs-f hbs-e1">`7110`</span><span className="hbs-nr">01360</span> | TK provider | — | X | — |
| <span className="hbs-g hbs-e0">**SG28.CAV**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7111 ZW3`</span><span className="hbs-nr">01370</span> | IP version | — | X | — |
| <span className="hbs-f hbs-e1">`7110`</span><span className="hbs-nr">01380</span> | IP version | — | X | — |
| <span className="hbs-g hbs-e0">**SG28.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7037 Z76`</span><span className="hbs-nr">01390</span> | Control box | — | X | — |
| <span className="hbs-g hbs-e0">**SG28.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7037 Z28`</span><span className="hbs-nr">01400</span> | Mounting type metering device | — | X | — |
| <span className="hbs-g hbs-e0">**SG28.CAV**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7111 BKE`</span><span className="hbs-nr">01410</span> | Plug-in technology (mounting and contacting device) | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`7111 DPA`</span><span className="hbs-nr">01420</span> | 3-Three-point suspension | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`7111 HUT`</span><span className="hbs-nr">01430</span> | DIN rail | — | X | <span className="hbs-marke">[4P0..1]</span> |
| <span className="hbs-f hbs-e1">`7111 Z31`</span><span className="hbs-nr">01440</span> | Single-connection meter | — | X | <span className="hbs-marke">[5P0..1]</span> |
| <span className="hbs-f hbs-e1">`7111 Z32`</span><span className="hbs-nr">01450</span> | Two-connection meter | — | X | <span className="hbs-marke">[5P0..1]</span> |
| <span className="hbs-g hbs-e0">**SG28.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7037 E12`</span><span className="hbs-nr">01460</span> | Meter reading capture at the metering device | — | X | — |
| <span className="hbs-g hbs-e0">**SG28.CAV**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7111 AMR`</span><span className="hbs-nr">01470</span> | remotely readable meters | — | X | — |
| <span className="hbs-f hbs-e1">`7111 MMR`</span><span className="hbs-nr">01480</span> | manually read meters | — | X | — |
| <span className="hbs-g hbs-e0">**SG31.PRI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`5125 CAL`</span><span className="hbs-nr">01490</span> | Calculation price | — | X | — |
| <span className="hbs-f hbs-e1">`5118`</span><span className="hbs-nr">01500</span> | Price, amount | — | X | <span className="hbs-marke">[912]</span> |
| <span className="hbs-f hbs-e1">`5284`</span><span className="hbs-nr">01510</span> | Unit price basis, quantity | — | X | <span className="hbs-marke">[908]</span> |
| <span className="hbs-f hbs-e1">`6411 H87`</span><span className="hbs-nr">01520</span> | Piece | — | X | <span className="hbs-marke">[79]</span> |
| <span className="hbs-f hbs-e1">`6411 DAY`</span><span className="hbs-nr">01530</span> | Day | — | X | <span className="hbs-marke">[80]</span> |
| <span className="hbs-g hbs-e0">**SG32.RFF**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1153 Z09`</span><span className="hbs-nr">01540</span> | Device number | — | X | — |
| <span className="hbs-f hbs-e1">`1154`</span><span className="hbs-nr">01550</span> | Device number | — | X | — |
| <span className="hbs-g hbs-e0">**SG32.RFF**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1153 APF`</span><span className="hbs-nr">01560</span> | Reference to catalogue number | — | X | — |
| <span className="hbs-f hbs-e1">`1154`</span><span className="hbs-nr">01570</span> | Catalog number | — | X | — |
| <span className="hbs-f hbs-e1">`1156`</span><span className="hbs-nr">01580</span> | Line number | — | X | — |
| <span className="hbs-f hbs-e1">`1056`</span><span className="hbs-nr">01590</span> | Version number | — | X | — |
| <span className="hbs-g hbs-e0">**SG42.NAD**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3035 VY`</span><span className="hbs-nr">01600</span> | other associated party | — | X | — |
| <span className="hbs-f hbs-e1">`3039`</span><span className="hbs-nr">01610</span> | MP-ID | — | X | — |
| <span className="hbs-f hbs-e1">`3055 9`</span><span className="hbs-nr">01620</span> | GS1 | — | X | — |
| <span className="hbs-f hbs-e1">`3055 293`</span><span className="hbs-nr">01630</span> | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| <span className="hbs-f hbs-e1">`3055 332`</span><span className="hbs-nr">01640</span> | DE, DVGW Service & Consult GmbH | — | X | — |
| <span className="hbs-g hbs-e0">**UNS**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`0081 S`</span><span className="hbs-nr">01650</span> | Separation of detail and summary section | — | X | — |
| <span className="hbs-g hbs-e0">**UNT**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`0074`</span><span className="hbs-nr">01660</span> | Number of segments in a message | — | X | — |
| <span className="hbs-f hbs-e1">`0062`</span><span className="hbs-nr">01670</span> | Message reference number | — | X | — |

</div>

</Handbuchsatz>

### Conditions of this table

The free text of the 33 conditions referenced by the rows above. All conditions of the message type are listed in the [condition index QUOTES](/en/referenz/202610/ahb-bedingungen/QUOTES).

<div className="maco-tabellenrahmen">

| Marker | Condition |
|---|---|
| **[1]** | If the item cannot be offered because legal provisions or third-party rights preclude this |
| **[2]** | If in the same SG27 LIN IMD DE7081 (product/service description) with code Z09 (cannot be offered) is not present. |
| **[3]** | If CCI+++Z64 is present |
| **[4]** | If present on the device and different from the device number |
| **[5]** | If in the same SG27 LIN the article number 9990001000649 is present |
| **[10]** | If SG28 CAV+MIW/MPW/MBW present |
| **[22]** | If CCI+++Z75 is present |
| **[31]** | Only the article numbers are permitted that are marked with the corresponding check identifier in the code list of article numbers of the BDEW. |
| **[72]** | if the code EM is present in DE3155 in the same COM |
| **[73]** | if the code TE / FX / AJ / AL is present in DE3155 in the same COM |
| **[79]** | If IMD DE7081 (product/service description) with value Z07 (purchase) is present. |
| **[80]** | If IMD DE7081 (product/service description) with value Z08 (provision for use) is present. |
| **[492]** | if MP-ID in NAD+MR from division electricity |
| **[493]** | if MP-ID in NAD+MR from division gas |
| **[494]** | The date stated here must be the point in time at which the document was created, or a point in time before that. |
| **[500]** | Note: Indication of a technical contact person for the device takeover |
| **[502]** | Note: Use of the ID of the metering location |
| **[504]** | Note: Value from BGM+311 DE1004 of the REQOTE with which the quotation request was made. |
| **[516]** | Note: Only one piece of information may be transmitted in DE3148 |
| **[908]** | Format: possible values: 1 to n |
| **[911]** | Format: Possible values: 1 to n, starting at 1 for each message or segment group and ascending consecutively |
| **[912]** | Format: max. 6 decimal places |
| **[914]** | Format: Possible value: &gt; 0 |
| **[931]** | Format: ZZZ = +00 |
| **[939]** | Format: the character string must contain the characters @ and . |
| **[940]** | Format: the character string must begin with the character + and may only be followed by digits |
| **[951]** | Format: Metering point identifier |
| **[UB3]** | ([931] ∧ [932] [492] ∧ [490]) ⊻ ([931] ∧ [933] [492] ∧ [491]) ⊻ ([931] ∧ [934] [493] ∧ [490]) ⊻ ([931] ∧ [935] [493] ∧ [491]) |
| **[1P0..1]** | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
| **[4P0..1]** | [492 ]  if MP-ID in NAD+MR from division electricity |
| **[5P0..1]** | [493 ]  if MP-ID in NAD+MR from division gas |
| **[2P0..1]** | [8] If SG28 CCI+++E13 CAV+EHZ present |
| **[3P0..1]** | [25] If SG28 CCI+++E13 CAV+MME present |

</div>

## Example message

### Example 1

<div data-maco="beispielfall" className="maco-beispielfall">

<Beispielnachricht>

```text title="EDIFACT"
UNA:+.? '
UNB+UNOC:3+9906464000001:500+9904446000007:500+{{date}}:{{time}}+MC1KD4Q0'
UNH+UNHMCEYDAOS+QUOTES:D:10A:UN:1.3c'
BGM+310+BGMMCM3BZLS'
DTM+137:202610011100?+00:303'
DTM+76:202509302200?+00:303'
IMD++Z07'
RFF+AAV:REQOTE123456'
RFF+Z13:15001'
CUX+2:EUR:4'
NAD+MS+9906464000001::293'
CTA+IC+:Mustermann'
COM+?+012345678910:TE'
NAD+MR+9904446000007::293'
NAD+DP'
LOC+172+DE0032106765712000000000000001234'
LIN+1++9990001000649:Z01'
DTM+94:2025:602'
DTM+Z04:2033:602'
GIN+BN+SERIAL123456'
FTX+ACB+++weil ich das so sage'
CCI+++E13'
CAV+MME:::Z04'
CAV+ETZ'
CAV+ERZ'
CCI+++Z28'
CAV+BKE'
CCI+++E12'
CAV+MMR'
PRI+CAL:100:::1:H87'
RFF+Z09:1ESY0012345678'
RFF+APF:1:2:3'
LIN+2++9990001000657:Z01'
DTM+Z03:2025:602'
CCI+++Z25'
CAV+MIW:::50'
PRI+CAL:300:::2:H87'
RFF+Z09:WANDLER1'
RFF+Z09:WANDLER2'
LIN+3++9990001000772:Z01'
IMD++Z09'
NAD+VY+9904858000009::293'
LIN+4++9990001000665:Z01'
DTM+94:2025:602'
GIN+BN+SERIAL777777'
CCI+++Z26'
CAV+LTE'
PRI+CAL:1:::100:H87'
RFF+Z09:LTE123'
UNS+S'
UNT+49+UNHMCEYDAOS'
UNZ+1+MC1KD4Q0'
```

```json title="BO4E-JSON"
[
  {
    "businessKey": "<businessKey>",
    "processDate": null,
    "dataSource": "OUTBOUND",
    "version": 1,
    "edifactVersion": 202610,
    "data": {
      "stammdaten": {
        "MESSLOKATION": [
          {
            "boTyp": "MESSLOKATION",
            "versionStruktur": "1",
            "messlokationsId": "DE0032106765712000000000000001234",
            "sparte": "STROM"
          }
        ],
        "ANFRAGE": [
          {
            "boTyp": "ANFRAGE",
            "versionStruktur": "1",
            "lokationsId": "DE0032106765712000000000000001234",
            "lokationsTyp": "MELO",
            "anfragetyp": "KAUF"
          }
        ],
        "ANGEBOT": [
          {
            "boTyp": "ANGEBOT",
            "versionStruktur": "1",
            "anfragereferenz": "REQOTE123456",
            "angebotsdatum": "2025-09-30T22:00:00Z",
            "sparte": "STROM",
            "gesamtkosten": {
              "waehrung": "EUR"
            },
            "positionsdaten": [
              {
                "positionsbezeichnung": "1",
                "positionspreis": [
                  {
                    "wert": 100,
                    "menge": 1,
                    "bezugswert": "STUECK"
                  }
                ],
                "artikelnummer": "ZAEHLEINRICHTUNG",
                "freitext": "weil ich das so sage",
                "verweisKatalognummer": {
                  "katalognummer": "1",
                  "zeilennummer": "2",
                  "versionsnummer": "3"
                }
              },
              {
                "positionsbezeichnung": "2",
                "positionspreis": [
                  {
                    "wert": 300,
                    "menge": 2,
                    "bezugswert": "STUECK"
                  }
                ],
                "artikelnummer": "WANDLER_MENGENUMWERTER"
              },
              {
                "positionsbezeichnung": "3",
                "anbietbar": false,
                "artikelnummer": "SMARTMETER_GATEWAY",
                "beteiligterMarktpartner": {
                  "boTyp": "MARKTTEILNEHMER",
                  "versionStruktur": "1",
                  "gewerbekennzeichnung": true,
                  "rollencodenummer": "9904858000009",
                  "rollencodetyp": "BDEW"
                }
              },
              {
                "positionsbezeichnung": "4",
                "positionspreis": [
                  {
                    "wert": 1,
                    "menge": 100,
                    "bezugswert": "STUECK"
                  }
                ],
                "artikelnummer": "KOMMUNIKATIONSEINRICHTUNG"
              }
            ]
          }
        ],
        "ZAEHLER": [
          {
            "boTyp": "ZAEHLER",
            "versionStruktur": "1",
            "zaehlernummer": "1ESY0012345678",
            "sparte": "STROM",
            "zaehlerauspraegung": "EINRICHTUNGSZAEHLER",
            "zaehlertyp": "MODERNEMESSEINRICHTUNG",
            "tarifart": "EINTARIF",
            "eichungBis": "2033",
            "messwerterfassung": "MANUELL_AUSGELESENE",
            "zaehlertypspezifikation": "MME_STANDARD",
            "befestigungsart": "STECKTECHNIK",
            "geraete": [
              {
                "geraetenummer": "WANDLER1",
                "weitereGeraetenummern": [
                  "WANDLER2"
                ],
                "geraeteeigenschaften": {
                  "geraetetyp": "WANDLER",
                  "geraetemerkmal": "MESSWANDLERSATZ_IMS_MME",
                  "faktor": 50,
                  "baujahr": "2025"
                }
              },
              {
                "geraeteeigenschaften": {
                  "geraetetyp": "SMARTMETERGATEWAY"
                }
              },
              {
                "geraetenummer": "LTE123",
                "geraeteeigenschaften": {
                  "geraetetyp": "KOMMUNIKATIONSEINRICHTUNG",
                  "geraetemerkmal": "LTE_KOM",
                  "herstellungsdatum": "2025",
                  "serialnummer": "SERIAL777777"
                }
              }
            ],
            "serialnummer": "SERIAL123456",
            "herstellungsdatum": "2025"
          }
        ]
      },
      "transaktionsdaten": {
        "datenaustauschreferenz": "MC1KD4Q0",
        "sparte": "STROM",
        "pruefidentifikator": "15001",
        "absender": {
          "boTyp": "MARKTTEILNEHMER",
          "versionStruktur": "1",
          "rollencodenummer": "9906464000001",
          "rollencodetyp": "BDEW",
          "ansprechpartner": {
            "boTyp": "ANSPRECHPARTNER",
            "versionStruktur": "1",
            "nachname": "Mustermann",
            "rufnummern": [
              {
                "nummerntyp": "RUF_DURCHWAHL",
                "rufnummer": "+012345678910"
              }
            ]
          }
        },
        "empfaenger": {
          "boTyp": "MARKTTEILNEHMER",
          "versionStruktur": "1",
          "rollencodenummer": "9904446000007",
          "rollencodetyp": "BDEW"
        },
        "dokumentennummer": "BGMMCM3BZLS",
        "kategorie": "310",
        "nachrichtendatum": "2026-10-01T11:00:00Z",
        "nachrichtenreferenznummer": "UNHMCEYDAOS"
      },
      "zusatzdaten": {}
    }
  }
]
```

</Beispielnachricht>

*Source: [`1.edi`](https://github.com/conuti-gmbh/maco-edi-testfiles/blob/main/inbound/v202610/quotes/15001/1.edi) · [`1.json`](https://github.com/conuti-gmbh/maco-edi-testfiles/blob/main/outbound/v202610/quotes/15001/1.json)*

<Testdateien edi="/testdaten/202610/quotes/15001/1.edi" json="/testdaten/202610/quotes/15001/1.json" />

</div>

### Example 2

<div data-maco="beispielfall" className="maco-beispielfall">

<Beispielnachricht>

```text title="EDIFACT"
UNA:+.? '
UNB+UNOC:3+9906464000001:500+9904446000007:500+{{date}}:{{time}}+MCVYAG0T'
UNH+UNHMCD6T51U+QUOTES:D:10A:UN:1.3c'
BGM+310+BGMMCM3BZLS'
DTM+137:202610011100?+00:303'
DTM+76:202506302200?+00:303'
IMD++Z07'
RFF+AAV:REQOTE123456'
RFF+Z13:15001'
CUX+2:EUR:4'
NAD+MS+9906464000001::293'
CTA+IC+:Mustermann'
COM+012345678910:TE'
NAD+MR+9904446000007::293'
NAD+DP'
LOC+172+DE0032106765712000000000000001234'
LIN+1++9990001000649:Z01'
DTM+94:2023:602'
DTM+Z04:2033:602'
GIN+BN+SERIAL123456'
FTX+ACB+++Allgemeine Informationen'
CCI+++E13'
CAV+MME:::Z04'
CAV+ETZ'
CAV+ERZ'
CCI+++Z28'
CAV+BKE'
CCI+++E12'
CAV+MMR'
PRI+CAL:100:::1:H87'
RFF+Z09:1ESY0012345678'
RFF+APF:1:2:3'
LIN+2++9990001000657:Z01'
DTM+Z03:2022:602'
CCI+++Z25'
CAV+MIW:::50'
PRI+CAL:300:::2:H87'
RFF+Z09:WANDLER1'
RFF+Z09:WANDLER2'
LIN+3++9990001000665:Z01'
DTM+94:2021:602'
GIN+BN+SERIAL777777'
CCI+++Z26'
CAV+DSL'
PRI+CAL:1:::100:H87'
RFF+Z09:LTE123'
LIN+4++9990001000673:Z01'
DTM+94:2020:602'
CCI+++Z27'
CAV+RSU'
PRI+CAL:50:::1:H87'
RFF+Z09:RSU123'
LIN+5++9990001000699:Z01'
DTM+94:2022:602'
PRI+CAL:1:::1:H87'
RFF+Z09:ABC123'
LIN+6++9990001000772:Z01'
DTM+Z03:2020:602'
DTM+Z04:2033:602'
CCI+++Z75'
CAV+ZV8:::2.4'
CAV+ZV9:::PX44123XW2.0'
CAV+ZW0:::2349203472346'
CAV+ZW1:::26204567890111'
CAV+ZW2:::Telekom'
CAV+ZW3:::IPv6'
PRI+CAL:1:::1:H87'
RFF+Z09:SMG12345'
LIN+7++9990001000780:Z01'
DTM+94:2020:602'
CCI+++Z76'
PRI+CAL:2:::1:H87'
UNS+S'
UNT+72+UNHMCD6T51U'
UNZ+1+MCVYAG0T'
```

```json title="BO4E-JSON"
[
  {
    "businessKey": "<businessKey>",
    "processDate": null,
    "dataSource": "OUTBOUND",
    "version": 1,
    "edifactVersion": 202610,
    "data": {
      "stammdaten": {
        "MESSLOKATION": [
          {
            "boTyp": "MESSLOKATION",
            "versionStruktur": "1",
            "messlokationsId": "DE0032106765712000000000000001234",
            "sparte": "STROM"
          }
        ],
        "ANFRAGE": [
          {
            "boTyp": "ANFRAGE",
            "versionStruktur": "1",
            "anfragetyp": "KAUF"
          }
        ],
        "ANGEBOT": [
          {
            "boTyp": "ANGEBOT",
            "versionStruktur": "1",
            "anfragereferenz": "REQOTE123456",
            "angebotsdatum": "2025-06-30T22:00:00Z",
            "sparte": "STROM",
            "gesamtkosten": {
              "waehrung": "EUR"
            },
            "positionsdaten": [
              {
                "positionsbezeichnung": "1",
                "positionspreis": [
                  {
                    "wert": 100,
                    "menge": 1,
                    "bezugswert": "STUECK"
                  }
                ],
                "artikelnummer": "ZAEHLEINRICHTUNG",
                "freitext": "Allgemeine Informationen",
                "verweisKatalognummer": {
                  "katalognummer": "1",
                  "zeilennummer": "2",
                  "versionsnummer": "3"
                }
              },
              {
                "positionsbezeichnung": "2",
                "positionspreis": [
                  {
                    "wert": 300,
                    "menge": 2,
                    "bezugswert": "STUECK"
                  }
                ],
                "artikelnummer": "WANDLER_MENGENUMWERTER"
              },
              {
                "positionsbezeichnung": "3",
                "positionspreis": [
                  {
                    "wert": 1,
                    "menge": 100,
                    "bezugswert": "STUECK"
                  }
                ],
                "artikelnummer": "KOMMUNIKATIONSEINRICHTUNG"
              },
              {
                "positionsbezeichnung": "4",
                "positionspreis": [
                  {
                    "wert": 50,
                    "menge": 1,
                    "bezugswert": "STUECK"
                  }
                ],
                "artikelnummer": "TECHNISCHE_STEUEREINRICHTUNG"
              },
              {
                "positionsbezeichnung": "5",
                "positionspreis": [
                  {
                    "wert": 1,
                    "menge": 1,
                    "bezugswert": "STUECK"
                  }
                ],
                "artikelnummer": "BEFESTIGUNGSEINRICHTUNG"
              },
              {
                "positionsbezeichnung": "6",
                "positionspreis": [
                  {
                    "wert": 1,
                    "menge": 1,
                    "bezugswert": "STUECK"
                  }
                ],
                "artikelnummer": "SMARTMETER_GATEWAY"
              },
              {
                "positionsbezeichnung": "7",
                "positionspreis": [
                  {
                    "wert": 2,
                    "menge": 1,
                    "bezugswert": "STUECK"
                  }
                ],
                "artikelnummer": "STEUERBOX"
              }
            ]
          }
        ],
        "ZAEHLER": [
          {
            "boTyp": "ZAEHLER",
            "versionStruktur": "1",
            "zaehlernummer": "1ESY0012345678",
            "sparte": "STROM",
            "zaehlerauspraegung": "EINRICHTUNGSZAEHLER",
            "zaehlertyp": "MODERNEMESSEINRICHTUNG",
            "tarifart": "EINTARIF",
            "eichungBis": "2033",
            "messwerterfassung": "MANUELL_AUSGELESENE",
            "zaehlertypspezifikation": "MME_STANDARD",
            "befestigungsart": "STECKTECHNIK",
            "serialnummer": "SERIAL123456",
            "herstellungsdatum": "2023",
            "geraete": [
              {
                "geraetenummer": "WANDLER1",
                "weitereGeraetenummern": [
                  "WANDLER2"
                ],
                "geraeteeigenschaften": {
                  "geraetetyp": "WANDLER",
                  "geraetemerkmal": "MESSWANDLERSATZ_IMS_MME",
                  "faktor": 50,
                  "baujahr": "2022"
                }
              },
              {
                "geraetenummer": "LTE123",
                "geraeteeigenschaften": {
                  "geraetetyp": "KOMMUNIKATIONSEINRICHTUNG",
                  "geraetemerkmal": "DSL_KOM",
                  "herstellungsdatum": "2021",
                  "serialnummer": "SERIAL777777"
                }
              },
              {
                "geraetenummer": "RSU123",
                "geraeteeigenschaften": {
                  "geraetetyp": "TECHNISCHESTEUEREINRICHTUNG",
                  "geraetemerkmal": "RUNDSTEUEREMPFAENGER",
                  "herstellungsdatum": "2020"
                }
              },
              {
                "geraetenummer": "ABC123",
                "geraeteeigenschaften": {
                  "geraetetyp": "BEFESTIGUNGSEINRICHTUNG",
                  "herstellungsdatum": "2022"
                }
              },
              {
                "geraetenummer": "SMG12345",
                "geraeteeigenschaften": {
                  "geraetetyp": "SMARTMETERGATEWAY",
                  "baujahr": "2020",
                  "eichungBis": "2030",
                  "firmwareVersion": "2.4",
                  "herstellerTypbezeichnung": "PX44123XW2.0",
                  "simKartenNummer": "2349203472346",
                  "modemKennungIMSI": "26204567890111",
                  "tkProvider": "Telekom",
                  "ipVersion": "IPv6"
                }
              },
              {
                "geraeteeigenschaften": {
                  "geraetetyp": "STEUERBOX",
                  "herstellungsdatum": "2020"
                }
              }
            ]
          }
        ]
      },
      "transaktionsdaten": {
        "datenaustauschreferenz": "MCVYAG0T",
        "sparte": "STROM",
        "pruefidentifikator": "15001",
        "absender": {
          "boTyp": "MARKTTEILNEHMER",
          "versionStruktur": "1",
          "gewerbekennzeichnung": true,
          "rollencodenummer": "9906464000001",
          "rollencodetyp": "BDEW",
          "ansprechpartner": {
            "boTyp": "ANSPRECHPARTNER",
            "versionStruktur": "1",
            "nachname": "Mustermann",
            "rufnummern": [
              {
                "nummerntyp": "RUF_DURCHWAHL",
                "rufnummer": "012345678910"
              }
            ]
          }
        },
        "empfaenger": {
          "boTyp": "MARKTTEILNEHMER",
          "versionStruktur": "1",
          "gewerbekennzeichnung": true,
          "rollencodenummer": "9904446000007",
          "rollencodetyp": "BDEW"
        },
        "dokumentennummer": "BGMMCM3BZLS",
        "kategorie": "310",
        "nachrichtendatum": "2026-10-01T11:00:00Z",
        "nachrichtenreferenznummer": "UNHMCD6T51U"
      },
      "zusatzdaten": {}
    }
  }
]
```

</Beispielnachricht>

*Source: [`2.edi`](https://github.com/conuti-gmbh/maco-edi-testfiles/blob/main/inbound/v202610/quotes/15001/2.edi) · [`2.json`](https://github.com/conuti-gmbh/maco-edi-testfiles/blob/main/outbound/v202610/quotes/15001/2.json)*

<Testdateien edi="/testdaten/202610/quotes/15001/2.edi" json="/testdaten/202610/quotes/15001/2.json" />

</div>

## Belongs to these role views

The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected is **MSB**.

<div className="maco-tabellenrahmen">

| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| MSB | MSBA | [Device takeover](/en/prozessdoku/202610/MSB--MSBA/awh-wim-gas-2-0-gerateubernahme) | AWH WiM gas 2.0 | Gas | Step 2 |
| MSB | MSBA | [Device takeover](/en/prozessdoku/202610/MSB--MSBA/WiM-Teil1-geraeteuebernahme) | WiM electricity part 1 | Electricity | Step 2 |
| MSB | MSBN | [Device takeover](/en/prozessdoku/202610/MSB--MSBN/awh-wim-gas-2-0-gerateubernahme) | AWH WiM gas 2.0 | Gas | Step 2 |
| MSB | MSBN | [Device takeover](/en/prozessdoku/202610/MSB--MSBN/WiM-Teil1-geraeteuebernahme) | WiM electricity part 1 | Electricity | Step 2 |

</div>

## Business classification

<div className="maco-tabellenrahmen">

| Attribute | Value |
|---|---|
| Use case (AHB) | Quotation for device takeover |
| AHB | QUOTES AHB |
| Transmission channel | AS4 |

</div>

:::caution{title="This check identifier is used in 3 contexts"}

Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.

:::

<div className="maco-tabellenrahmen">

| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| WiM electricity part 1 | Device takeover | MSB (corresponds to MSBA on the object metering location) → MSB (corresponds to MSBN on the object metering location) | Device takeover quotation |
| AWH WiM gas 2.0 | Device takeover | MSBA → MSBN | Device takeover quotation |
| WiM gas | Ch. B 5.2.3 No. 2 | MSBA → MSBN | Device takeover quotation |

</div>

:::caution{title="Individual entries from format version 202604"}

The check identifiers table of format version 202610 does not carry this entry: **process step**. It comes from version 202604. Version 202604 also carries this check identifier in contexts that the table of version 202610 does not know; they are included in the list above. Everything else on this page — use case, rulebook and communication direction — comes from its own version. Before adopting this into an implementation specification, check whether what is stated applies to 202610.

:::

## Transaction and responses

**Role of this check identifier: request.** Basis: the transaction data carry neither `antwortstatus` nor `antwortstatusCodeliste`, and neither the title nor the action of the Prüfi table begins with “response” or “response message”.

**Responses:** No response of this format version names this check identifier as a reference — neither explicitly in the Prüfi table nor via the step sequence. That does not mean there is none; it means that the sources do not record one.

**Check identifiers of the same AHB table:** No other check identifier of message type QUOTES has the same row structure in this version.

<Hinweisbereich>

An **\*** after a field or group name marks a **mandatory field** or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.

The status column carries two vocabularies because the manual answers two questions: on a **group row**, *Muss*, *Soll* or *Kann* states whether the EDIFACT segment must be present; on a **field row**, *X* states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.

For this check identifier, the application handbook lists **218 rows**. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.

The **Condition** column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.

The test data contains 2 transactions for this check identifier under the message type `quotes`. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.

:::note{title="Placeholder from the test data set"}

The test data set carries placeholders instead of valid values: `{{date}}` and `{{time}}` in the UNB interchange envelope of every EDIFACT file. **The page replaces these on call with the current date and the current time** — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.

`<businessKey>` stays in place. It is not a time value, and an invented key would look like a valid one.

:::

</Hinweisbereich>