# Check identifier 55073 — Transmission of the profile definitions

<span hidden data-pagefind-meta={"title:Check identifier 55073 — Transmission of the profile definitions · UTILMD · Format version 202610"} />

Check identifier **55073** · EDIFACT message type **UTILMD** · Format version **202610**

:::info{title="This page is derived from the application handbook"}

The MACO APP does not carry this check identifier. The complete Prüfi pages of this level are produced from the specifications of the application — one class in the templater per check identifier — and that is where the **assignment to the business objects (BO4E)** comes from: which object carries which field of the message.

The catalogue of the application handbook is the larger set. This page therefore shows what the handbook itself provides — use case, process context and the AHB field list with its conditions. A data structure according to BO4E is not shown, and not because there is none, but because the application does not form one for this check identifier.

All check identifiers in this situation — and the corresponding figures — are listed by [the overview of this version](/en/schnittstellen/202610/pruefi/nicht-gefuehrt).

:::

## Application handbook (AHB)

<Handbuchsatz>

<div className="maco-tabellenrahmen" data-maco="ahb-tabelle">

| Structure (EDIFACT) | Description | Format | <span className="hbs-p" title="Übermittlung der Profildefinitionen">55073</span> | Condition |
|---|---|---|---|---|
| <span className="hbs-g hbs-e0">**UNH**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`0062`</span><span className="hbs-nr">00010</span> | Message reference number | — | X | — |
| <span className="hbs-f hbs-e1">`0065 UTILMD`</span><span className="hbs-nr">00020</span> | Grid connection master data | — | X | — |
| <span className="hbs-f hbs-e1">`0052 D`</span><span className="hbs-nr">00030</span> | Draft version | — | X | — |
| <span className="hbs-f hbs-e1">`0054 11A`</span><span className="hbs-nr">00040</span> | Edition 2011 - A | — | X | — |
| <span className="hbs-f hbs-e1">`0051 UN`</span><span className="hbs-nr">00050</span> | UN/CEFACT | — | X | — |
| <span className="hbs-f hbs-e1">`0057 S2.2`</span><span className="hbs-nr">00060</span> | Version number of the underlying BDEW message description | — | X | — |
| <span className="hbs-g hbs-e0">**BGM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1001 Z18`</span><span className="hbs-nr">00070</span> | Profile definition | — | X | — |
| <span className="hbs-f hbs-e1">`1004`</span><span className="hbs-nr">00080</span> | Document number | — | X | — |
| <span className="hbs-g hbs-e0">**DTM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`2005 137`</span><span className="hbs-nr">00090</span> | Document-/ message date/time | — | X | — |
| <span className="hbs-f hbs-e1">`2380`</span><span className="hbs-nr">00100</span> | Date or time or time span, value | — | X | <span className="hbs-marke">[931]</span> <span className="hbs-marke">[494]</span> |
| <span className="hbs-f hbs-e1">`2379 303`</span><span className="hbs-nr">00110</span> | CCYYMMDDHHMMZZZ | — | X | — |
| <span className="hbs-g hbs-e0">**DTM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`2005 157`</span><span className="hbs-nr">00120</span> | Validity, start date | — | X | — |
| <span className="hbs-f hbs-e1">`2380`</span><span className="hbs-nr">00130</span> | Date or time or time span, value | — | X | — |
| <span className="hbs-f hbs-e1">`2379 610`</span><span className="hbs-nr">00140</span> | CCYYMM | — | X | — |
| <span className="hbs-g hbs-e0">**SG2.NAD**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3035 MS`</span><span className="hbs-nr">00150</span> | Document-/ message sender or sender | — | X | — |
| <span className="hbs-f hbs-e1">`3039`</span><span className="hbs-nr">00160</span> | MP-ID | — | X | — |
| <span className="hbs-f hbs-e1">`3055 9`</span><span className="hbs-nr">00170</span> | GS1 | — | X | — |
| <span className="hbs-f hbs-e1">`3055 293`</span><span className="hbs-nr">00180</span> | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| <span className="hbs-g hbs-e0">**SG2.NAD**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3035 MR`</span><span className="hbs-nr">00190</span> | Message recipient | — | X | — |
| <span className="hbs-f hbs-e1">`3039`</span><span className="hbs-nr">00200</span> | MP-ID | — | X | <span className="hbs-marke">[280]</span> |
| <span className="hbs-f hbs-e1">`3055 9`</span><span className="hbs-nr">00210</span> | GS1 | — | X | — |
| <span className="hbs-f hbs-e1">`3055 293`</span><span className="hbs-nr">00220</span> | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| <span className="hbs-g hbs-e0">**SG4.IDE**</span> | — | — | Must | <span className="hbs-marke">[564]</span> |
| <span className="hbs-f hbs-e1">`7495 Z01`</span><span className="hbs-nr">00230</span> | List | — | X | — |
| <span className="hbs-f hbs-e1">`7402`</span><span className="hbs-nr">00240</span> | List number | — | X | — |
| <span className="hbs-g hbs-e0">**SG6.RFF**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1153 Z13`</span><span className="hbs-nr">00250</span> | Check identifier | — | X | — |
| <span className="hbs-f hbs-e1">`1154 55073`</span><span className="hbs-nr">00260</span> | MaBiS / Transmission of the profile definitions | — | X | — |
| <span className="hbs-g hbs-e0">**SG4.IDE**</span> | — | — | Must | <span className="hbs-marke">[504]</span> ∧ <span className="hbs-marke">[565]</span> |
| <span className="hbs-f hbs-e1">`7495 24`</span><span className="hbs-nr">00270</span> | Transaction | — | X | — |
| <span className="hbs-f hbs-e1">`7402`</span><span className="hbs-nr">00280</span> | Transaction number | — | X | — |
| <span className="hbs-g hbs-e0">**SG4.FTX**</span> | — | — | Must | <span className="hbs-marke">[52]</span> Should <span className="hbs-marke">[53]</span> |
| <span className="hbs-f hbs-e1">`4451 Z01`</span><span className="hbs-nr">00290</span> | Profile description | — | X | — |
| <span className="hbs-f hbs-e1">`4440`</span><span className="hbs-nr">00300</span> | Text for further description | — | X | — |
| <span className="hbs-g hbs-e0">**SG8.SEQ**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1229 Z21`</span><span className="hbs-nr">00310</span> | Profile data | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7059 Z07`</span><span className="hbs-nr">00320</span> | Profile type | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z38`</span><span className="hbs-nr">00330</span> | Commercial general | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z39`</span><span className="hbs-nr">00340</span> | Commercial weekdays 8 - 18 | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z40`</span><span className="hbs-nr">00350</span> | Commercial with strong to predominant consumption in the evening hours | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z41`</span><span className="hbs-nr">00360</span> | Commercial continuous | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z42`</span><span className="hbs-nr">00370</span> | Commercial shop/hairdresser | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z43`</span><span className="hbs-nr">00380</span> | Commercial bakery with bakehouse | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z44`</span><span className="hbs-nr">00390</span> | Commercial weekend operation | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z45`</span><span className="hbs-nr">00400</span> | Agricultural businesses, general | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z46`</span><span className="hbs-nr">00410</span> | Agricultural businesses with dairy farming/ part-time livestock breeding | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z47`</span><span className="hbs-nr">00420</span> | Agriculture without dairy cattle | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z48`</span><span className="hbs-nr">00430</span> | Household | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z49`</span><span className="hbs-nr">00440</span> | Band load | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z50`</span><span className="hbs-nr">00450</span> | interruptible consumption device | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z51`</span><span className="hbs-nr">00460</span> | Space heating storage | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z52`</span><span className="hbs-nr">00470</span> | Street lighting | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z53`</span><span className="hbs-nr">00480</span> | Photovoltaic market location | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z54`</span><span className="hbs-nr">00490</span> | Combined heat and power plant | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z55`</span><span className="hbs-nr">00500</span> | other consuming market location | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z56`</span><span className="hbs-nr">00510</span> | other generating market location | — | X | — |
| <span className="hbs-f hbs-e1">`7037 ZC6`</span><span className="hbs-nr">00520</span> | E-mobility charging point in a public area | — | X | — |
| <span className="hbs-f hbs-e1">`7037 ZC7`</span><span className="hbs-nr">00530</span> | E-mobility charging point of a household | — | X | — |
| <span className="hbs-f hbs-e1">`7037 ZC8`</span><span className="hbs-nr">00540</span> | E-mobility charging point of a commercial business | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7059 Z02`</span><span className="hbs-nr">00550</span> | Standard load profile | — | X | — |
| <span className="hbs-f hbs-e1">`7059 Z04`</span><span className="hbs-nr">00560</span> | Standard feed-in profile | — | X | — |
| <span className="hbs-f hbs-e1">`7037 E01`</span><span className="hbs-nr">00570</span> | synthetic method | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z10`</span><span className="hbs-nr">00580</span> | analytical method | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CAV**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7111`</span><span className="hbs-nr">00590</span> | Code of the standardized profile | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7059 Z06`</span><span className="hbs-nr">00600</span> | Normalization factor | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z35`</span><span className="hbs-nr">00610</span> | 1.000.000 kWh/a | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z37`</span><span className="hbs-nr">00620</span> | 1.000.000 kW | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7059 Z20`</span><span className="hbs-nr">00630</span> | Balancing area | — | X | — |
| <span className="hbs-f hbs-e1">`7037`</span><span className="hbs-nr">00640</span> | Balancing area | — | X | — |
| <span className="hbs-g hbs-e0">**SG8.SEQ**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1229 Z08`</span><span className="hbs-nr">00650</span> | Profile set data | — | X | — |
| <span className="hbs-g hbs-e0">**SG8.PIA**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`4347 Z01`</span><span className="hbs-nr">00660</span> | Calculation of the daily mean temperature | — | X | — |
| <span className="hbs-f hbs-e1">`7143 Z03`</span><span className="hbs-nr">00670</span> | 24h average | — | X | — |
| <span className="hbs-f hbs-e1">`7143 Z04`</span><span className="hbs-nr">00680</span> | equivalent daily mean temperature provided by the provider | — | X | — |
| <span className="hbs-f hbs-e1">`7143 Z05`</span><span className="hbs-nr">00690</span> | Equivalent daily mean temperature | — | X | — |
| <span className="hbs-g hbs-e0">**SG9.QTY**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`6063 Z11`</span><span className="hbs-nr">00700</span> | Share A | — | X | — |
| <span className="hbs-f hbs-e1">`6060`</span><span className="hbs-nr">00710</span> | Share A in % | — | X | <span className="hbs-marke">[902]</span> ∧ <span className="hbs-marke">[930]</span> |
| <span className="hbs-g hbs-e0">**SG9.QTY**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`6063 Z12`</span><span className="hbs-nr">00720</span> | Share B | — | X | — |
| <span className="hbs-f hbs-e1">`6060`</span><span className="hbs-nr">00730</span> | Share B in % | — | X | <span className="hbs-marke">[902]</span> ∧ <span className="hbs-marke">[930]</span> |
| <span className="hbs-g hbs-e0">**SG9.QTY**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`6063 Z13`</span><span className="hbs-nr">00740</span> | Share C | — | X | — |
| <span className="hbs-f hbs-e1">`6060`</span><span className="hbs-nr">00750</span> | Share C in % | — | X | <span className="hbs-marke">[902]</span> ∧ <span className="hbs-marke">[930]</span> |
| <span className="hbs-g hbs-e0">**SG9.QTY**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`6063 Z14`</span><span className="hbs-nr">00760</span> | Share D | — | X | — |
| <span className="hbs-f hbs-e1">`6060`</span><span className="hbs-nr">00770</span> | Share D in % | — | X | <span className="hbs-marke">[902]</span> ∧ <span className="hbs-marke">[930]</span> |
| <span className="hbs-g hbs-e0">**SG9.QTY**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`6063 Z15`</span><span className="hbs-nr">00780</span> | Reference temperature | — | X | — |
| <span className="hbs-f hbs-e1">`6060`</span><span className="hbs-nr">00790</span> | Temperature in °C | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7059 Z07`</span><span className="hbs-nr">00800</span> | Profile type | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z38`</span><span className="hbs-nr">00810</span> | Commercial general | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z39`</span><span className="hbs-nr">00820</span> | Commercial weekdays 8 - 18 | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z40`</span><span className="hbs-nr">00830</span> | Commercial with strong to predominant consumption in the evening hours | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z41`</span><span className="hbs-nr">00840</span> | Commercial continuous | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z42`</span><span className="hbs-nr">00850</span> | Commercial shop/hairdresser | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z43`</span><span className="hbs-nr">00860</span> | Commercial bakery with bakehouse | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z44`</span><span className="hbs-nr">00870</span> | Commercial weekend operation | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z45`</span><span className="hbs-nr">00880</span> | Agricultural businesses, general | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z46`</span><span className="hbs-nr">00890</span> | Agricultural businesses with dairy farming/ part-time livestock breeding | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z47`</span><span className="hbs-nr">00900</span> | Agriculture without dairy cattle | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z48`</span><span className="hbs-nr">00910</span> | Household | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z49`</span><span className="hbs-nr">00920</span> | Band load | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z50`</span><span className="hbs-nr">00930</span> | interruptible consumption device | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z51`</span><span className="hbs-nr">00940</span> | Space heating storage | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z52`</span><span className="hbs-nr">00950</span> | Street lighting | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z53`</span><span className="hbs-nr">00960</span> | Photovoltaic market location | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z54`</span><span className="hbs-nr">00970</span> | Combined heat and power plant | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z55`</span><span className="hbs-nr">00980</span> | other consuming market location | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z56`</span><span className="hbs-nr">00990</span> | other generating market location | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7037 Z12`</span><span className="hbs-nr">01000</span> | Profile set | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CAV**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7111`</span><span className="hbs-nr">01010</span> | Code of the profile set | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7059 Z03`</span><span className="hbs-nr">01020</span> | day-parameter-dependent load profile | — | X | — |
| <span className="hbs-f hbs-e1">`7059 Z05`</span><span className="hbs-nr">01030</span> | day-parameter-dependent feed-in profile | — | X | — |
| <span className="hbs-f hbs-e1">`7037 E01`</span><span className="hbs-nr">01040</span> | synthetic method | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z10`</span><span className="hbs-nr">01050</span> | analytical method | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CAV**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7111`</span><span className="hbs-nr">01060</span> | Code of the standardized profile | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7059 Z06`</span><span className="hbs-nr">01070</span> | Normalization factor | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z35`</span><span className="hbs-nr">01080</span> | 1.000.000 kWh/a | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z36`</span><span className="hbs-nr">01090</span> | 300 kWh/K | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z37`</span><span className="hbs-nr">01100</span> | 1.000.000 kW | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7059 Z11`</span><span className="hbs-nr">01110</span> | Limiting constant | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z61`</span><span className="hbs-nr">01120</span> | 0 | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z62`</span><span className="hbs-nr">01130</span> | 1 | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7059 Z99`</span><span className="hbs-nr">01140</span> | Measuring station of the daily parameter (currently only the temperature is a permitted daily parameter) | — | X | — |
| <span className="hbs-f hbs-e1">`7059 ZA0`</span><span className="hbs-nr">01150</span> | Climate zone of the daily parameter (currently is daily parameter) | — | X | — |
| <span className="hbs-f hbs-e1">`7037`</span><span className="hbs-nr">01160</span> | ID of climate zone / temperature measuring point | — | X | — |
| <span className="hbs-f hbs-e1">`1131`</span><span className="hbs-nr">01170</span> | Service provider | — | X | <span className="hbs-marke">[58]</span> |
| <span className="hbs-f hbs-e1">`3055 89`</span><span className="hbs-nr">01180</span> | Assigned by the trader (here grid operator) | — | X | — |
| <span className="hbs-f hbs-e1">`3055 293`</span><span className="hbs-nr">01190</span> | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7059 Z20`</span><span className="hbs-nr">01200</span> | Balancing area | — | X | — |
| <span className="hbs-f hbs-e1">`7037`</span><span className="hbs-nr">01210</span> | Balancing area | — | X | — |
| <span className="hbs-g hbs-e0">**SG8.SEQ**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1229 Z38`</span><span className="hbs-nr">01220</span> | Reference profile data | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7059 Z07`</span><span className="hbs-nr">01230</span> | Profile type | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z53`</span><span className="hbs-nr">01240</span> | Photovoltaic market location | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z56`</span><span className="hbs-nr">01250</span> | other generating market location | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7059 Z05`</span><span className="hbs-nr">01260</span> | day-parameter-dependent feed-in profile | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CAV**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7111`</span><span className="hbs-nr">01270</span> | Code of the reference profile | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7059 Z06`</span><span className="hbs-nr">01280</span> | Normalization factor | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z35`</span><span className="hbs-nr">01290</span> | 1.000.000 kWh/a | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z37`</span><span className="hbs-nr">01300</span> | 1.000.000 kW | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7059 Z20`</span><span className="hbs-nr">01310</span> | Balancing area | — | X | — |
| <span className="hbs-f hbs-e1">`7037`</span><span className="hbs-nr">01320</span> | Balancing area | — | X | — |
| <span className="hbs-g hbs-e0">**UNT**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`0074`</span><span className="hbs-nr">01330</span> | Number of segments in a message | — | X | — |
| <span className="hbs-f hbs-e1">`0062`</span><span className="hbs-nr">01340</span> | Message reference number | — | X | — |

</div>

</Handbuchsatz>

### Conditions of this table

The free text of the 11 conditions referenced by the rows above. All conditions of the message type are listed in the [condition index UTILMDS](/en/referenz/202610/ahb-bedingungen/UTILMDS).

<div className="maco-tabellenrahmen">

| Marker | Condition |
|---|---|
| **[52]** | If SG10 CCI+Z07++Z55/Z56 (profile type: other consuming market location / other generating market location) is present |
| **[53]** | If further specifications beyond CCI+Z07 (profile type) are possible |
| **[58]** | If in this CCI the DE3055 with the code 293 is present |
| **[280]** | Only MP-ID from the electricity division |
| **[494]** | The date stated here must be the point in time at which the document was created, or a point in time before that |
| **[504]** | Note: One transaction required per profile (including profile set where applicable) |
| **[564]** | Note: The IDE+Z01 (list) defines the business transaction. All listed IDE+24 are part of the business transaction |
| **[565]** | Note: The IDE+24 describes a component of a list if a IDE+Z01 is present. It does not describe the business transaction |
| **[902]** | Format: Possible value: ≥ 0 |
| **[930]** | Format: max. 2 decimal places |
| **[931]** | Format: ZZZ = +00 |

</div>

## Belongs to these role views

The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are **LF**, **NB** and **MSB**.

<div className="maco-tabellenrahmen">

| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | [Transmission of the list of profile definitions from the NB to LF or ÜNB](/en/prozessdoku/202610/LF/MaBiS-uebermittlung-der-liste-der-profildefinitionen-vom-nb-an-lf-bzw-uenb) | MaBiS | Electricity | Step 1 |
| NB | NB | [Transmission of the list of profile definitions from the NB to LF or ÜNB](/en/prozessdoku/202610/NB/MaBiS-uebermittlung-der-liste-der-profildefinitionen-vom-nb-an-lf-bzw-uenb) | MaBiS | Electricity | Step 1 |
| NB | NB | [Transmission of the list of profile definitions from the NB to MSB](/en/prozessdoku/202610/NB/MaBiS-uebermittlung-der-liste-der-profildefinitionen-vom-nb-an-msb) | MaBiS | Electricity | Step 1 |
| MSB | MSB | [Transmission of the list of profile definitions from the NB to MSB](/en/prozessdoku/202610/MSB/MaBiS-uebermittlung-der-liste-der-profildefinitionen-vom-nb-an-msb) | MaBiS | Electricity | Step 1 |

</div>

## Business classification

<div className="maco-tabellenrahmen">

| Attribute | Value |
|---|---|
| Use case (AHB) | Transmission of the profile definitions |
| AHB | UTILMD AHB electricity |
| Transmission channel | AS4 |

</div>

:::caution{title="This check identifier is used in 3 contexts"}

Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.

:::

<div className="maco-tabellenrahmen">

| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| MaBiS | Transmission of the list of profile definitions from the NB to MSB | NB → MSB | Transmission of the list of profile definitions |
| MaBiS | Transmission of the list of profile definitions from the NB to LF or ÜNB | NB → LF | Transmission of the list of profile definitions |
| MaBiS | Transmission of the list of profile definitions from the NB to LF or ÜNB | NB → ÜNB | Transmission of the list of profile definitions |

</div>

<Hinweisbereich>

The status column carries two vocabularies because the manual answers two questions: on a **group row**, *Muss*, *Soll* or *Kann* states whether the EDIFACT segment must be present; on a **field row**, *X* states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.

For this check identifier, the application handbook lists **173 rows**. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.

The **Condition** column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.

</Hinweisbereich>