:::info{title="This page is derived from the application handbook"}

The MACO APP does not carry this check identifier. The complete Prüfi pages of this level are produced from the specifications of the application — one class in the templater per check identifier — and that is where the **assignment to the business objects (BO4E)** comes from: which object carries which field of the message.

The catalogue of the application handbook is the larger set. This page therefore shows what the handbook itself provides — use case, process context and the AHB field list with its conditions. A data structure according to BO4E is not shown, and not because there is none, but because the application does not form one for this check identifier.

All check identifiers in this situation — and the corresponding figures — are listed by [the overview of this version](/en/schnittstellen/202610/pruefi/nicht-gefuehrt).

:::

## Application handbook (AHB)

<Handbuchsatz>

<div className="maco-tabellenrahmen" data-maco="ahb-tabelle">

| Structure (EDIFACT) | Description | Format | <span className="hbs-p" title="Antwort auf Stammdatenänderung">55076</span> | Condition |
|---|---|---|---|---|
| <span className="hbs-g hbs-e0">**UNH**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`0062`</span><span className="hbs-nr">00010</span> | Message reference number | — | X | — |
| <span className="hbs-f hbs-e1">`0065 UTILMD`</span><span className="hbs-nr">00020</span> | Grid connection master data | — | X | — |
| <span className="hbs-f hbs-e1">`0052 D`</span><span className="hbs-nr">00030</span> | Draft version | — | X | — |
| <span className="hbs-f hbs-e1">`0054 11A`</span><span className="hbs-nr">00040</span> | Edition 2011 - A | — | X | — |
| <span className="hbs-f hbs-e1">`0051 UN`</span><span className="hbs-nr">00050</span> | UN/CEFACT | — | X | — |
| <span className="hbs-f hbs-e1">`0057 S2.2`</span><span className="hbs-nr">00060</span> | Version number of the underlying BDEW message description | — | X | — |
| <span className="hbs-g hbs-e0">**BGM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1001 E03`</span><span className="hbs-nr">00070</span> | Change notifications | — | X | — |
| <span className="hbs-f hbs-e1">`1004`</span><span className="hbs-nr">00080</span> | Document number | — | X | — |
| <span className="hbs-g hbs-e0">**DTM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`2005 137`</span><span className="hbs-nr">00090</span> | Document/message date/time | — | X | — |
| <span className="hbs-f hbs-e1">`2380`</span><span className="hbs-nr">00100</span> | Date or time or time span, value | — | X | <span className="hbs-marke">[931]</span> <span className="hbs-marke">[494]</span> |
| <span className="hbs-f hbs-e1">`2379 303`</span><span className="hbs-nr">00110</span> | CCYYMMDDHHMMZZZ | — | X | — |
| <span className="hbs-g hbs-e0">**SG2.NAD**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3035 MS`</span><span className="hbs-nr">00120</span> | Document-/ message sender or sender | — | X | — |
| <span className="hbs-f hbs-e1">`3039`</span><span className="hbs-nr">00130</span> | MP-ID | — | X | — |
| <span className="hbs-f hbs-e1">`3055 9`</span><span className="hbs-nr">00140</span> | GS1 | — | X | — |
| <span className="hbs-g hbs-e0">**SG2.NAD**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3035 MR`</span><span className="hbs-nr">00150</span> | Message recipient | — | X | — |
| <span className="hbs-f hbs-e1">`3039`</span><span className="hbs-nr">00160</span> | MP-ID | — | X | <span className="hbs-marke">[280]</span> |
| <span className="hbs-f hbs-e1">`3055 9`</span><span className="hbs-nr">00170</span> | GS1 | — | X | — |
| <span className="hbs-f hbs-e1">`3055 293`</span><span className="hbs-nr">00180</span> | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| <span className="hbs-g hbs-e0">**SG4.IDE**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7495 24`</span><span className="hbs-nr">00190</span> | Transaction | — | X | — |
| <span className="hbs-f hbs-e1">`7402`</span><span className="hbs-nr">00200</span> | Transaction number | — | X | — |
| <span className="hbs-g hbs-e0">**SG4.DTM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`2005 157`</span><span className="hbs-nr">00210</span> | Validity, start date | — | X | — |
| <span className="hbs-f hbs-e1">`2380`</span><span className="hbs-nr">00220</span> | Date or time or time span, value | — | X | <span className="hbs-marke">[UB1]</span> |
| <span className="hbs-f hbs-e1">`2379 303`</span><span className="hbs-nr">00230</span> | CCYYMMDDHHMMZZZ | — | X | — |
| <span className="hbs-g hbs-e0">**SG4.STS**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`9015 7`</span><span className="hbs-nr">00240</span> | Transaction reason | — | X | — |
| <span className="hbs-f hbs-e1">`9013 E03`</span><span className="hbs-nr">00250</span> | Change | — | X | — |
| <span className="hbs-f hbs-e1">`9013 ZE3`</span><span className="hbs-nr">00260</span> | Master data change | — | X | — |
| <span className="hbs-g hbs-e0">**SG4.STS**</span> | — | — | Must | <span className="hbs-marke">[249]</span> |
| <span className="hbs-f hbs-e1">`9015 E01`</span><span className="hbs-nr">00270</span> | Status of the response | — | X | — |
| <span className="hbs-f hbs-e1">`9013`</span><span className="hbs-nr">00280</span> | Code of the check step | — | X | — |
| <span className="hbs-f hbs-e1">`1131 S_0091`</span><span className="hbs-nr">00290</span> | Electricity code list no. S_0091 | — | X | — |
| <span className="hbs-g hbs-e0">**SG5.LOC**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3227 Z16`</span><span className="hbs-nr">00300</span> | Market location | — | X | — |
| <span className="hbs-f hbs-e1">`3225`</span><span className="hbs-nr">00310</span> | ID of the market location | — | X | <span className="hbs-marke">[950]</span> |
| <span className="hbs-g hbs-e0">**SG5.LOC**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3227 Z21`</span><span className="hbs-nr">00320</span> | Tranche | — | X | — |
| <span className="hbs-f hbs-e1">`3225`</span><span className="hbs-nr">00330</span> | ID of the tranche | — | X | <span className="hbs-marke">[950]</span> |
| <span className="hbs-g hbs-e0">**SG5.LOC**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3227 Z17`</span><span className="hbs-nr">00340</span> | Metering location | — | X | — |
| <span className="hbs-f hbs-e1">`3225`</span><span className="hbs-nr">00350</span> | ID of the metering location | — | X | <span className="hbs-marke">[951]</span> |
| <span className="hbs-g hbs-e0">**SG6.RFF**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1153 Z13`</span><span className="hbs-nr">00360</span> | Check identifier | — | X | — |
| <span className="hbs-f hbs-e1">`1154 55076`</span><span className="hbs-nr">00370</span> | HKNR / Response to master data change | — | X | — |
| <span className="hbs-g hbs-e0">**SG6.RFF**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1153 TN`</span><span className="hbs-nr">00380</span> | Transaction reference number | — | X | — |
| <span className="hbs-f hbs-e1">`1154`</span><span className="hbs-nr">00390</span> | Transaction number | — | X | — |
| <span className="hbs-g hbs-e0">**SG8.SEQ**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1229 Z01`</span><span className="hbs-nr">00400</span> | Data of the market location | — | X | — |
| <span className="hbs-g hbs-e0">**SG8.RFF**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1153 Z18`</span><span className="hbs-nr">00410</span> | Market location | — | X | — |
| <span className="hbs-f hbs-e1">`1154`</span><span className="hbs-nr">00420</span> | ID of the market location | — | X | <span className="hbs-marke">[950]</span> |
| <span className="hbs-g hbs-e0">**SG10.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7037 ZB3`</span><span className="hbs-nr">00430</span> | Assigned market partner | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CAV**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7111 Z89`</span><span className="hbs-nr">00440</span> | LF | — | X | — |
| <span className="hbs-f hbs-e1">`1131`</span><span className="hbs-nr">00450</span> | MP-ID | — | X | <span className="hbs-marke">[611]</span> |
| <span className="hbs-g hbs-e0">**SG10.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7059 Z19`</span><span className="hbs-nr">00460</span> | Balancing group | — | X | — |
| <span className="hbs-f hbs-e1">`7037`</span><span className="hbs-nr">00470</span> | Balancing group | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7059 15`</span><span className="hbs-nr">00480</span> | Structure | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z21`</span><span className="hbs-nr">00490</span> | Aggregated time series type | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CAV**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7111`</span><span className="hbs-nr">00500</span> | Code of the time series type | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7037 Z34`</span><span className="hbs-nr">00510</span> | Type of the generating market location | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CAV**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7111 Z33`</span><span className="hbs-nr">00520</span> | EEG market location without DV obligation | — | X | — |
| <span className="hbs-f hbs-e1">`7111 Z34`</span><span className="hbs-nr">00530</span> | KWKG market location without DV obligation | — | X | — |
| <span className="hbs-f hbs-e1">`7111 Z35`</span><span className="hbs-nr">00540</span> | other market location | — | X | — |
| <span className="hbs-f hbs-e1">`7111 Z37`</span><span className="hbs-nr">00550</span> | EEG market location with DV obligation | — | X | — |
| <span className="hbs-f hbs-e1">`7111 Z46`</span><span className="hbs-nr">00560</span> | KWKG market location with DV obligation | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7059 Z22`</span><span className="hbs-nr">00570</span> | Statutory category | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z90`</span><span className="hbs-nr">00580</span> | EEG- marketing type: default remuneration | — | X | <span className="hbs-marke">[695]</span> |
| <span className="hbs-f hbs-e1">`7037 Z91`</span><span className="hbs-nr">00590</span> | EEG- marketing type: market premium | — | X | <span className="hbs-marke">[696]</span> |
| <span className="hbs-f hbs-e1">`7037 Z92`</span><span className="hbs-nr">00600</span> | Marketing type without statutory remuneration | — | X | <span className="hbs-marke">[696]</span> |
| <span className="hbs-f hbs-e1">`7037 Z94`</span><span className="hbs-nr">00610</span> | KWKG remuneration | — | X | <span className="hbs-marke">[695]</span> |
| <span className="hbs-g hbs-e0">**SG10.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7059 Z23`</span><span className="hbs-nr">00620</span> | Country of production | — | X | — |
| <span className="hbs-f hbs-e1">`7037`</span><span className="hbs-nr">00630</span> | Country of production | — | X | — |
| <span className="hbs-f hbs-e1">`1131 LAND`</span><span className="hbs-nr">00640</span> | EDI@Energy code list of European country codes | — | X | — |
| <span className="hbs-f hbs-e1">`3055 293`</span><span className="hbs-nr">00650</span> | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| <span className="hbs-g hbs-e0">**SG8.SEQ**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1229 Z02`</span><span className="hbs-nr">00660</span> | OBIS data of the market location | — | X | — |
| <span className="hbs-g hbs-e0">**SG8.RFF**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1153 Z18`</span><span className="hbs-nr">00670</span> | Market location | — | X | — |
| <span className="hbs-f hbs-e1">`1154`</span><span className="hbs-nr">00680</span> | ID of a market location | — | X | <span className="hbs-marke">[950]</span> |
| <span className="hbs-g hbs-e0">**SG8.PIA**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`4347 5`</span><span className="hbs-nr">00690</span> | Product identification | — | X | — |
| <span className="hbs-f hbs-e1">`7140`</span><span className="hbs-nr">00700</span> | OBIS code of the market location | — | X | <span className="hbs-marke">[314]</span> |
| <span className="hbs-f hbs-e1">`7143 SRW`</span><span className="hbs-nr">00710</span> | OBIS code | — | X | — |
| <span className="hbs-g hbs-e0">**SG8.SEQ**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1229 Z15`</span><span className="hbs-nr">00720</span> | Data of the tranche | — | X | — |
| <span className="hbs-g hbs-e0">**SG8.RFF**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1153 Z20`</span><span className="hbs-nr">00730</span> | Tranche | — | X | — |
| <span className="hbs-f hbs-e1">`1154`</span><span className="hbs-nr">00740</span> | ID of the tranche | — | X | <span className="hbs-marke">[950]</span> |
| <span className="hbs-g hbs-e0">**SG9.QTY**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`6063 11`</span><span className="hbs-nr">00750</span> | Distribution quantity | — | X | — |
| <span className="hbs-f hbs-e1">`6060`</span><span className="hbs-nr">00760</span> | Quantity specification in % | — | X | <span className="hbs-marke">[914]</span> ∧ <span className="hbs-marke">[930]</span> ∧ <span className="hbs-marke">[955]</span> |
| <span className="hbs-f hbs-e1">`6411 P1`</span><span className="hbs-nr">00770</span> | Percent | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7037 ZB3`</span><span className="hbs-nr">00780</span> | Assigned market partner | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CAV**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7111 Z89`</span><span className="hbs-nr">00790</span> | LF | — | X | — |
| <span className="hbs-f hbs-e1">`1131`</span><span className="hbs-nr">00800</span> | MP-ID | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7059 Z19`</span><span className="hbs-nr">00810</span> | Balancing group | — | X | — |
| <span className="hbs-f hbs-e1">`7037`</span><span className="hbs-nr">00820</span> | Balancing group | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7059 Z37`</span><span className="hbs-nr">00830</span> | Basis for determining the tranche size | — | X | — |
| <span className="hbs-f hbs-e1">`7037 ZD1`</span><span className="hbs-nr">00840</span> | Percentage-based | — | X | — |
| <span className="hbs-f hbs-e1">`7037 ZD2`</span><span className="hbs-nr">00850</span> | Distribution factor based on reference carrier/ installed capacity | — | X | — |
| <span className="hbs-f hbs-e1">`7037 ZH1`</span><span className="hbs-nr">00860</span> | Distribution across technical resources | — | X | — |
| <span className="hbs-g hbs-e0">**SG8.SEQ**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1229 Z17`</span><span className="hbs-nr">00870</span> | OBIS data of the tranche | — | X | — |
| <span className="hbs-g hbs-e0">**SG8.RFF**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1153 Z20`</span><span className="hbs-nr">00880</span> | Tranche | — | X | — |
| <span className="hbs-f hbs-e1">`1154`</span><span className="hbs-nr">00890</span> | ID of a tranche | — | X | <span className="hbs-marke">[950]</span> |
| <span className="hbs-g hbs-e0">**SG8.PIA**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`4347 5`</span><span className="hbs-nr">00900</span> | Product identification | — | X | — |
| <span className="hbs-f hbs-e1">`7140`</span><span className="hbs-nr">00910</span> | OBIS code of the tranche | — | X | <span className="hbs-marke">[269]</span> |
| <span className="hbs-f hbs-e1">`7143 SRW`</span><span className="hbs-nr">00920</span> | OBIS code | — | X | — |
| <span className="hbs-g hbs-e0">**SG8.SEQ**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1229 Z03`</span><span className="hbs-nr">00930</span> | Metering device data | — | X | — |
| <span className="hbs-g hbs-e0">**SG8.RFF**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1153 Z19`</span><span className="hbs-nr">00940</span> | Metering location | — | X | — |
| <span className="hbs-f hbs-e1">`1154`</span><span className="hbs-nr">00950</span> | ID of a metering location | — | X | <span className="hbs-marke">[951]</span> |
| <span className="hbs-g hbs-e0">**SG8.RFF**</span> | — | — | Should | <span className="hbs-marke">[166]</span> ∧ <span className="hbs-marke">[215]</span> |
| <span className="hbs-f hbs-e1">`1153 Z14`</span><span className="hbs-nr">00960</span> | Smart meter gateway | — | X | — |
| <span className="hbs-f hbs-e1">`1154`</span><span className="hbs-nr">00970</span> | Identification / number of the smart meter gateway | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7037 E13`</span><span className="hbs-nr">00980</span> | Meter type | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CAV**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7111 AHZ`</span><span className="hbs-nr">00990</span> | analog household meter (three-phase current) | — | X | — |
| <span className="hbs-f hbs-e1">`7111 WSZ`</span><span className="hbs-nr">01000</span> | analog alternating current meter | — | X | — |
| <span className="hbs-f hbs-e1">`7111 LAZ`</span><span className="hbs-nr">01010</span> | Load curve meter | — | X | — |
| <span className="hbs-f hbs-e1">`7111 MAZ`</span><span className="hbs-nr">01020</span> | Maximum demand meter | — | X | — |
| <span className="hbs-f hbs-e1">`7111 MME`</span><span className="hbs-nr">01030</span> | modern metering device according to MsbG | — | X | — |
| <span className="hbs-f hbs-e1">`7111 EHZ`</span><span className="hbs-nr">01040</span> | electronic household meter | — | X | — |
| <span className="hbs-f hbs-e1">`7111 IVA`</span><span className="hbs-nr">01050</span> | Individual reconciliation (special equipment) | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CAV**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7111 Z30`</span><span className="hbs-nr">01060</span> | Device number | — | X | — |
| <span className="hbs-f hbs-e1">`7110`</span><span className="hbs-nr">01070</span> | Device number | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CAV**</span> | — | — | Must | <span className="hbs-marke">[139]</span> |
| <span className="hbs-f hbs-e1">`7111 ETZ`</span><span className="hbs-nr">01080</span> | Single tariff | — | X | — |
| <span className="hbs-f hbs-e1">`7111 ZTZ`</span><span className="hbs-nr">01090</span> | Two-tariff | — | X | — |
| <span className="hbs-f hbs-e1">`7111 NTZ`</span><span className="hbs-nr">01100</span> | Multi-tariff | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CAV**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7111 ERZ`</span><span className="hbs-nr">01110</span> | Single-direction meter | — | X | — |
| <span className="hbs-f hbs-e1">`7111 ZRZ`</span><span className="hbs-nr">01120</span> | Bidirectional meter | — | X | — |
| <span className="hbs-g hbs-e0">**SG8.SEQ**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1229 Z20`</span><span className="hbs-nr">01130</span> | OBIS data of the metering device | — | X | — |
| <span className="hbs-g hbs-e0">**SG8.RFF**</span> | — | — | Must | <span className="hbs-marke">[665]</span> |
| <span className="hbs-f hbs-e1">`1153 MG`</span><span className="hbs-nr">01140</span> | Device number of the meter | — | X | <span className="hbs-marke">[441]</span> |
| <span className="hbs-f hbs-e1">`1153 Z14`</span><span className="hbs-nr">01150</span> | Smart meter gateway | — | X | — |
| <span className="hbs-f hbs-e1">`1154`</span><span className="hbs-nr">01160</span> | Device number | — | X | — |
| <span className="hbs-g hbs-e0">**SG8.RFF**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1153 Z19`</span><span className="hbs-nr">01170</span> | Metering location | — | X | — |
| <span className="hbs-f hbs-e1">`1154`</span><span className="hbs-nr">01180</span> | ID of a metering location | — | X | <span className="hbs-marke">[951]</span> |
| <span className="hbs-g hbs-e0">**SG8.RFF**</span> | — | — | Must | <span className="hbs-marke">[402]</span> ∧ <span className="hbs-marke">[420]</span> |
| <span className="hbs-f hbs-e1">`1153 AGK`</span><span className="hbs-nr">01190</span> | Application reference number | — | X | — |
| <span className="hbs-f hbs-e1">`1154`</span><span className="hbs-nr">01200</span> | Reference, identification | — | X | — |
| <span className="hbs-g hbs-e0">**SG8.PIA**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`4347 5`</span><span className="hbs-nr">01210</span> | Product identification | — | X | — |
| <span className="hbs-f hbs-e1">`7140`</span><span className="hbs-nr">01220</span> | OBIS code of the metering device | — | X | <span className="hbs-marke">[323]</span> |
| <span className="hbs-f hbs-e1">`7143 SRW`</span><span className="hbs-nr">01230</span> | OBIS code | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7037 ZE4`</span><span className="hbs-nr">01240</span> | Value granularity | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CAV**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7111 ZD9`</span><span className="hbs-nr">01250</span> | Annually | — | X | — |
| <span className="hbs-f hbs-e1">`7111 ZE8`</span><span className="hbs-nr">01260</span> | Semi-annual | — | X | — |
| <span className="hbs-f hbs-e1">`7111 ZE9`</span><span className="hbs-nr">01270</span> | Quarterly | — | X | — |
| <span className="hbs-f hbs-e1">`7111 ZB7`</span><span className="hbs-nr">01280</span> | Monthly | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7059 11`</span><span className="hbs-nr">01290</span> | Product | — | X | — |
| <span className="hbs-f hbs-e1">`7037 Z33`</span><span className="hbs-nr">01300</span> | Integer and decimal places of the register | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CAV**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7110`</span><span className="hbs-nr">01310</span> | Digits before the decimal point | — | X | — |
| <span className="hbs-f hbs-e1">`7110`</span><span className="hbs-nr">01320</span> | Digits after the decimal point | — | X | — |
| <span className="hbs-g hbs-e0">**SG8.SEQ**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1229 Z04`</span><span className="hbs-nr">01330</span> | Instrument transformer data | — | X | — |
| <span className="hbs-g hbs-e0">**SG8.RFF**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1153 MG`</span><span className="hbs-nr">01340</span> | Device number of the meter | — | X | — |
| <span className="hbs-f hbs-e1">`1154`</span><span className="hbs-nr">01350</span> | Device number | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7037 Z25`</span><span className="hbs-nr">01360</span> | Instrument transformer | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CAV**</span> | — | — | Must | <span className="hbs-marke">[2317]</span> ⊻ <span className="hbs-marke">[2318]</span> |
| <span className="hbs-f hbs-e1">`7111 Z30`</span><span className="hbs-nr">01370</span> | Device number | — | X | — |
| <span className="hbs-f hbs-e1">`7110`</span><span className="hbs-nr">01380</span> | Device number | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CAV**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7111 MIW`</span><span className="hbs-nr">01390</span> | Current transformer set | — | X | — |
| <span className="hbs-f hbs-e1">`7111 MPW`</span><span className="hbs-nr">01400</span> | Combined instrument transformer set (current and voltage) | — | X | — |
| <span className="hbs-f hbs-e1">`7111 MBW`</span><span className="hbs-nr">01410</span> | Block current transformer | — | X | — |
| <span className="hbs-f hbs-e1">`7111 MUW`</span><span className="hbs-nr">01420</span> | Voltage transformer set | — | X | — |
| <span className="hbs-f hbs-e1">`7110`</span><span className="hbs-nr">01430</span> | Instrument transformer factor | — | X | <span className="hbs-marke">[902]</span> <span className="hbs-marke">[141]</span> |
| <span className="hbs-g hbs-e0">**SG8.SEQ**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1229 Z13`</span><span className="hbs-nr">01440</span> | Smart meter gateway | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7037 Z75`</span><span className="hbs-nr">01450</span> | Smart meter gateway | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CAV**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7111 Z30`</span><span className="hbs-nr">01460</span> | Device number | — | X | — |
| <span className="hbs-f hbs-e1">`7110`</span><span className="hbs-nr">01470</span> | Device number | — | X | <span className="hbs-marke">[952]</span> |
| <span className="hbs-g hbs-e0">**SG8.SEQ**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1229 Z14`</span><span className="hbs-nr">01480</span> | Control box | — | X | — |
| <span className="hbs-g hbs-e0">**SG8.RFF**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1153 Z14`</span><span className="hbs-nr">01490</span> | Smart meter gateway | — | X | — |
| <span className="hbs-f hbs-e1">`1154`</span><span className="hbs-nr">01500</span> | Identification / number of the smart meter gateway | — | X | — |
| <span className="hbs-g hbs-e0">**SG8.RFF**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1153 Z18`</span><span className="hbs-nr">01510</span> | Market location | — | X | — |
| <span className="hbs-f hbs-e1">`1154`</span><span className="hbs-nr">01520</span> | ID of a market location | — | X | <span className="hbs-marke">[950]</span> |
| <span className="hbs-g hbs-e0">**SG10.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7037 Z76`</span><span className="hbs-nr">01530</span> | Control box | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CAV**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7111 Z30`</span><span className="hbs-nr">01540</span> | Device number | — | X | — |
| <span className="hbs-f hbs-e1">`7110`</span><span className="hbs-nr">01550</span> | Device number | — | X | <span className="hbs-marke">[952]</span> |
| <span className="hbs-g hbs-e0">**SG12.NAD**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3035 VY`</span><span className="hbs-nr">01560</span> | other associated party | — | X | — |
| <span className="hbs-f hbs-e1">`3039`</span><span className="hbs-nr">01570</span> | MP-ID | — | X | — |
| <span className="hbs-f hbs-e1">`3055 9`</span><span className="hbs-nr">01580</span> | GS1 | — | X | — |
| <span className="hbs-f hbs-e1">`3055 293`</span><span className="hbs-nr">01590</span> | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| <span className="hbs-g hbs-e0">**SG12.RFF**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1153 Z18`</span><span className="hbs-nr">01600</span> | Market location | — | X | — |
| <span className="hbs-f hbs-e1">`1153 Z20`</span><span className="hbs-nr">01610</span> | Tranche | — | X | — |
| <span className="hbs-f hbs-e1">`1154`</span><span className="hbs-nr">01620</span> | ID of a market location / tranche | — | X | <span className="hbs-marke">[950]</span> |
| <span className="hbs-g hbs-e0">**SG12.NAD**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3035 DP`</span><span className="hbs-nr">01630</span> | Supply address | — | X | — |
| <span className="hbs-f hbs-e1">`3124`</span><span className="hbs-nr">01640</span> | Additional information for identification | — | — | — |
| <span className="hbs-f hbs-e1">`3042`</span><span className="hbs-nr">01650</span> | Street and house number or PO box | — | — | S <span className="hbs-marke">[166]</span> M <span className="hbs-marke">[212]</span> |
| <span className="hbs-f hbs-e1">`3164`</span><span className="hbs-nr">01660</span> | City | — | X | — |
| <span className="hbs-f hbs-e1">`3251`</span><span className="hbs-nr">01670</span> | Postal code | — | X | — |
| <span className="hbs-f hbs-e1">`3207`</span><span className="hbs-nr">01680</span> | Country name, code | — | X | — |
| <span className="hbs-g hbs-e0">**UNT**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`0074`</span><span className="hbs-nr">01690</span> | Number of segments in a message | — | X | — |
| <span className="hbs-f hbs-e1">`0062`</span><span className="hbs-nr">01700</span> | Message reference number | — | X | — |

</div>

</Handbuchsatz>

### Conditions of this table

The free text of the 29 conditions referenced by the rows above. All conditions of the message type are listed in the [condition index UTILMDS](/en/referenz/202610/ahb-bedingungen/UTILMDS).

<div className="maco-tabellenrahmen">

| Marker | Condition |
|---|---|
| **[139]** | If SG10 CAV+IVA (individual reconciliation) not present in this SG8 |
| **[141]** | If SG10 CAV+MIW/MPW/MBW present |
| **[166]** | If present |
| **[212]** | If NAD DE3124 is not present in the same SG12 |
| **[215]** | If in the same SG8 (metering device data) SG10 CCI+++E13 CAV+MME (meter type: mME) is present |
| **[249]** | Within one SG4 IDE, all DE1131 of the SG4 STS+E01 (status of the response) must contain the identical value |
| **[269]** | All OBIS codes in accordance with EDI@Energy code list of OBIS codes and media for the German energy market, chapter 3, that are required at the tranche must be stated |
| **[280]** | Only MP-ID from the electricity division |
| **[314]** | All OBIS codes in accordance with the code list of OBIS codes and media, chapter 3, that are required at the market location must be stated. The minimum scope of the OBIS codes results from the metering product codes stated in chapter 5.1 of the document Code list of configurations |
| **[323]** | All OBIS codes in accordance with EDI@Energy code list of OBIS codes and media for the German energy market, chapter 3., that are used at the metering device must be stated. The minimum scope of the OBIS codes results from the metering product codes stated in chapter 5.1 of the document "Code list of configurations" |
| **[402]** | If in the same SG8 (OBIS data of the metering device / smart meter gateway) an OBIS code of the value type "meter reading" is present in the PIA+5 |
| **[420]** | If the RFF+Z14 (smart meter gateway) is present in this SG8 |
| **[441]** | If RFF+Z14 (reference to the smart meter gateway) is not present in the SG8+SEQ+Z03/ZF5 (metering device data) for the device number of a meter named in this RFF DE1154 |
| **[494]** | The date stated here must be the point in time at which the document was created, or a point in time before that |
| **[611]** | Note: If the company NB performs the tasks of the market role LF, the MP-ID of the company NB in the market role LF is to be stated |
| **[665]** | Note: If a meter is parameterized with a SMGW, no OBIS code numbers are stated for that meter. Only OBIS code numbers from the SMGW exist here |
| **[695]** | Note: Use if the role LF is assigned to a company NB |
| **[696]** | Note: Use only if the role LF is not assigned to a company NB |
| **[902]** | Format: Possible value: ≥ 0 |
| **[914]** | Format: Possible value: &gt; 0 |
| **[930]** | Format: max. 2 decimal places |
| **[931]** | Format: ZZZ = +00 |
| **[950]** | Format: market location ID |
| **[951]** | Format: Metering point identifier |
| **[952]** | Format: device number according to DIN 43863-5 |
| **[955]** | Format: Possible value: &lt; 100 |
| **[2317]** | If in the same SG8 SEQ+Z04/ZF7 (transformer data) the SG10 CCI+++Z25 (transformer) CAV+MIW/MPW/MUW is present, the segment must be specified at least twice |
| **[2318]** | If in the same SG8 SEQ+Z04/ZF7 (transformer data) the SG10 CCI+++Z25 (transformer) CAV+MBW (block current transformer ) is present, the segment must be specified exactly once |
| **[UB1]** | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |

</div>

## Belongs to these role views

There is no role view for this check identifier: in this format version no process step of any market role carries it. A role statement would stand here without evidence.

## Business classification

<div className="maco-tabellenrahmen">

| Attribute | Value |
|---|---|
| Use case (AHB) | Response to master data change |
| AHB | UTILMD AHB electricity |
| Transmission channel | MP |

</div>

:::caution{title="This check identifier is used in 3 contexts"}

Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.

:::

<div className="maco-tabellenrahmen">

| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| Processes for the exchange of information between grid operator and the guarantee of origin register (HKN-R) of the Federal Environment Agency (UBA) | Ch. 2.4 Case 1 No. 2 | RB HKN-R → NB | Response to master data change |
| Processes for the exchange of information between grid operator and the guarantee of origin register (HKN-R) of the Federal Environment Agency (UBA) | Ch. 2.4 Case 2 No. 2 | RB HKN-R → NB | Response to master data change |
| Processes for the exchange of information between grid operator and the guarantee of origin register (HKN-R) of the Federal Environment Agency (UBA) | Ch. 2.4 Case 4 No. 2 | RB HKN-R → NB | Response to master data change |

</div>

<Hinweisbereich>

The status column carries two vocabularies because the manual answers two questions: on a **group row**, *Muss*, *Soll* or *Kann* states whether the EDIFACT segment must be present; on a **field row**, *X* states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.

For this check identifier, the application handbook lists **242 rows**. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.

The **Condition** column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.

</Hinweisbereich>