# Check identifier 55617 — Change to data of TR

<span hidden data-pagefind-meta={"title:Check identifier 55617 — Change of TR data · UTILMD · Format version 202610"} />

Check identifier **55617** · EDIFACT message type **UTILMD** · format version **202610**

## Data structure

<Handbuchsatz>

<div className="maco-tabellenrahmen">

| Structure (BO4E) | Description | Format | <span className="hbs-p" title="Änderung Daten der TR">55617</span> | Condition |
|---|---|---|---|---|
| <span className="hbs-g hbs-e0">**stammdaten** <span className="hbs-pflicht">\*</span></span> | — | object | Must | — |
| <span className="hbs-g hbs-e1">**TECHNISCHE_RESSOURCE** <span className="hbs-liste">[ ]</span> <span className="hbs-pflicht">\*</span></span> | — | object[] | Must | — |
| <span className="hbs-f hbs-e2">[art](/en/bo4e/202610/bo/TechnischeRessource#art)</span> <AhbTabelle pruefid="55617" format="UTILMD" fv="202610" zeile={73} segment="SG4.IDE+24.SG8.SEQ+Z52.SG10.CCI+[Z17\|Z50\|Z56]" /><span className="hbs-nr">00010</span> | Technical resource type | [Enum TechnischeRessourceArt](/en/bo4e/202610/enum/TechnischeRessourceArt) | Must | — |
| <span className="hbs-w hbs-e3">`STROMERZEUGUNG`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`STROMVERBRAUCH`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`SPEICHER`</span> | — | — | Must | — |
| <span className="hbs-f hbs-e2">[artEMobilitaet](/en/bo4e/202610/bo/TechnischeRessource#artemobilitaet)</span> <AhbTabelle pruefid="55617" format="UTILMD" fv="202610" zeile={48} segment="SG4.IDE+24.SG8.SEQ+Z52.SG10.CCI+[Z17\|Z50\|Z56].CAV" /><span className="hbs-nr">00020</span> | ArtEmobilitaet | [Enum ArtEmobilitaet](/en/bo4e/202610/enum/ArtEmobilitaet) | Must | <span className="hbs-marke">[446]</span> |
| <span className="hbs-w hbs-e3">`WB`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`LS`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`LP`</span> | — | — | Must | — |
| <span className="hbs-f hbs-e2">[datenqualitaet](/en/bo4e/202610/bo/TechnischeRessource#datenqualitaet)</span> <AhbTabelle pruefid="55617" format="UTILMD" fv="202610" zeile={50} segment="SG4.IDE+24.SG8.SEQ+Z52" /><span className="hbs-nr">00030</span> | Data quality | [Enum Datenqualitaet](/en/bo4e/202610/enum/Datenqualitaet) | X | — |
| <span className="hbs-w hbs-e3">`ERWARTETE_DATEN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`IM_SYSTEM_VORHANDENE_DATEN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`INFORMATIVE_DATEN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`GUELTIGE_DATEN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`KEINE_DATEN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`IM_SYSTEM_KEINE_DATEN_VORHANDEN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`KEINE_DATEN_ERWARTET`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`DIFFERENZ_DATEN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`DIFFERENZ_ERWARTETE_DATEN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`DIFFERENZ_IM_SYSTEM_VORHANDENE_DATEN`</span> | — | — | X | — |
| <span className="hbs-f hbs-e2">[einordnung](/en/bo4e/202610/bo/TechnischeRessource#einordnung)</span> <AhbTabelle pruefid="55617" format="UTILMD" fv="202610" zeile={48} segment="SG4.IDE+24.SG8.SEQ+Z52.SG10.CCI+[Z17\|Z50\|Z56].CAV+[ZH2\|ZH3\|ZH4\|ZH5]" /><span className="hbs-nr">00040</span> | RessourceWechselmoeglichkeit | [Enum RessourceWechselmoeglichkeit](/en/bo4e/202610/enum/RessourceWechselmoeglichkeit) | Must | <span className="hbs-marke">[446]</span> |
| <span className="hbs-w hbs-e3">`WECHSELMOEGLICHKEIT_EINMALIG_NOCH_MOEGLICH`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`WECHSELMOEGLICHKEIT_NICHT_MOEGLICH`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`BEFRISTET_OHNE_WECHSELMOEGLICHKEIT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`WECHSEL_WURDE_DURCHGEFUEHRT`</span> | — | — | Must | — |
| <span className="hbs-f hbs-e2">[enwg](/en/bo4e/202610/bo/TechnischeRessource#enwg)</span> <AhbTabelle pruefid="55617" format="UTILMD" fv="202610" zeile={48} segment="SG4.IDE+24.SG8.SEQ+Z52.SG10.CCI+[Z17\|Z50\|Z56].CAV+[ZG8\|ZG9]" /><span className="hbs-nr">00050</span> | enwg | boolean | Must | <span className="hbs-marke">[446]</span> |
| <span className="hbs-f hbs-e2">[erzeugungsart](/en/bo4e/202610/bo/TechnischeRessource#erzeugungsart)</span> <AhbTabelle pruefid="55617" format="UTILMD" fv="202610" zeile={48} segment="SG4.IDE+24.SG8.SEQ+Z52.SG10.CCI+[Z17\|Z50\|Z56].CAV+[ZF5\|ZF6\|ZG0\|ZG1\|ZG5]" /><span className="hbs-nr">00060</span> | Type of energy generation. Details generation type<br/>Example: CAV+ZF5'<br/>Generation type:<br/>ZF5: solar<br/>ZF6: wind<br/>ZG0: gas<br/>ZG1: water<br/>ZG5: other generation type | [Enum Erzeugungsart](/en/bo4e/202610/enum/Erzeugungsart) | Must | <span className="hbs-marke">[446]</span> |
| <span className="hbs-w hbs-e3">`EEG`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`KWK`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`EEG_DV`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`KWK_DV`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`WIND`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`SOLAR`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`KERNKRAFT`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`WASSER`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`GEOTHERMIE`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`BIOMASSE`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`KOHLE`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`GAS`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`SONSTIGE`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`SONSTIGE_EEG`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`SONSTIGE_ERZEUGUNGSART`</span> | — | — | Must | — |
| <span className="hbs-f hbs-e2">[inbetriebsetzungsdatum](/en/bo4e/202610/bo/TechnischeRessource#inbetriebsetzungsdatum)</span> <AhbTabelle pruefid="55617" format="UTILMD" fv="202610" zeile={48} segment="SG4.IDE+24.SG8.SEQ+Z52.SG10.CCI+[Z17\|Z50\|Z56].CAV+[ZH0\|ZH1]" /><span className="hbs-nr">00070</span> | Commissioning | [Enum Inbetriebsetzung](/en/bo4e/202610/enum/Inbetriebsetzung) | Must | <span className="hbs-marke">[446]</span> |
| <span className="hbs-w hbs-e3">`INBETRIEBSETZUNG_NACH_2023`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`INBETRIEBSETZUNG_VOR_2024`</span> | — | — | Must | — |
| <span className="hbs-f hbs-e2">[referenzNetzlokation](/en/bo4e/202610/bo/TechnischeRessource#referenznetzlokation)</span> <AhbTabelle pruefid="55617" format="UTILMD" fv="202610" zeile={55} segment="SG4.IDE+24.SG8.SEQ+Z52.RFF+Z32" /><span className="hbs-nr">00080</span> | referenzNetzlokation | string | X | — |
| <span className="hbs-f hbs-e2">[referenzSteuerbareRessource](/en/bo4e/202610/bo/TechnischeRessource#referenzsteuerbareressource)</span> <AhbTabelle pruefid="55617" format="UTILMD" fv="202610" zeile={52} segment="SG4.IDE+24.SG8.SEQ+Z52.RFF+Z38" /><span className="hbs-nr">00090</span> | referenzSteuerbareRessource | string | X | — |
| <span className="hbs-f hbs-e2">[referenzTranche](/en/bo4e/202610/bo/TechnischeRessource#referenztranche)</span> <AhbTabelle pruefid="55617" format="UTILMD" fv="202610" zeile={58} segment="SG4.IDE+24.SG8.SEQ+Z52.RFF+Z20" /><span className="hbs-nr">00100</span> | referenzTranche | string | X | — |
| <span className="hbs-f hbs-e2">[ressourcenId](/en/bo4e/202610/bo/TechnischeRessource#ressourcenid) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="55617" format="UTILMD" fv="202610" zeile={31} segment="SG4.IDE+24.SG5.LOC+Z20" /><span className="hbs-nr">00110</span> | ressourcenId | string | X | — |
| <span className="hbs-f hbs-e2">[speicherart](/en/bo4e/202610/bo/TechnischeRessource#speicherart)</span> <AhbTabelle pruefid="55617" format="UTILMD" fv="202610" zeile={48} segment="SG4.IDE+24.SG8.SEQ+Z52.SG10.CCI+[Z17\|Z50\|Z56].CAV+[ZF7\|ZF8\|ZF9\|ZG6]" /><span className="hbs-nr">00120</span> | Type of storage. Details storage type<br/>Example: CAV+ZF7'<br/>Storage type:<br/>ZF7: hydrogen storage<br/>ZF8: pumped storage<br/>ZF9: battery storage<br/>ZG6: other storage type | [Enum Speicherart](/en/bo4e/202610/enum/Speicherart) | Must | <span className="hbs-marke">[446]</span> |
| <span className="hbs-w hbs-e3">`WASSERSTOFFSPEICHER`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`PUMPSPEICHER`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`BATTERIESPEICHER`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`SONSTIGE_SPEICHERART`</span> | — | — | Must | — |
| <span className="hbs-f hbs-e2">[speicherkapazitaet](/en/bo4e/202610/bo/TechnischeRessource#speicherkapazitaet)</span> <AhbTabelle pruefid="55617" format="UTILMD" fv="202610" zeile={70} segment="SG4.IDE+24.SG8.SEQ+Z52.SG9.QTY+Z42" /><span className="hbs-nr">00130</span> | Storage capacity<br/>Example: QTY+Z42:100:KWH' | number (float) | X | — |
| <span className="hbs-f hbs-e2">[verbrauchsart](/en/bo4e/202610/bo/TechnischeRessource#verbrauchsart)</span> <AhbTabelle pruefid="55617" format="UTILMD" fv="202610" zeile={48} segment="SG4.IDE+24.SG8.SEQ+Z52.SG10.CCI+[Z17\|Z50\|Z56].CAV+[Z65\|ZE5\|ZA8]" /><span className="hbs-nr">00140</span> | Consumption type of the technical resource<br/>Example: CAV+Z64'<br/>Z64: Power/light<br/>Z65: Heat<br/>ZE5: E-mobility<br/>ZA8: Street lighting | array | Must | <span className="hbs-marke">[446]</span> |
| <span className="hbs-f hbs-e2">[verguetungsverpflichtung](/en/bo4e/202610/bo/TechnischeRessource#verguetungsverpflichtung)</span> <AhbTabelle pruefid="55617" format="UTILMD" fv="202610" zeile={116} segment="SG4.IDE+24.SG8.SEQ+Z52.SG10.CCI+Z68" /><span className="hbs-nr">00150</span> | verguetungsverpflichtung | boolean | X | — |
| <span className="hbs-f hbs-e2">[waermenutzung](/en/bo4e/202610/bo/TechnischeRessource#waermenutzung)</span> <AhbTabelle pruefid="55617" format="UTILMD" fv="202610" zeile={48} segment="SG4.IDE+24.SG8.SEQ+Z52.SG10.CCI+[Z17\|Z50\|Z56].CAV" /><span className="hbs-nr">00160</span> | Heat usage<br/>Example: CAV+Z56'<br/>Z56: Storage heating<br/>Z57: Heat pump<br/>Z61: Direct heating | [Enum Waermenutzung](/en/bo4e/202610/enum/Waermenutzung) | Must | <span className="hbs-marke">[446]</span> |
| <span className="hbs-w hbs-e3">`SPEICHERHEIZUNG`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`WAERMEPUMPE`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`DIREKTHEIZUNG`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`WAERMEPUMPE_WAERME_KAELTE`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`WAERMEPUMPE_KAELTE`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`WAERMEPUMPE_WAERME`</span> | — | — | Must | — |
| <span className="hbs-g hbs-e2">**gueltigkeitszeitraum**</span> | — | object | May | — |
| <span className="hbs-f hbs-e3">[zeitraumId](/en/bo4e/202610/com/Zeitraum#zeitraumid)</span> <AhbTabelle pruefid="55617" format="UTILMD" fv="202610" zeile={50} segment="SG4.IDE+24.SG8.SEQ+Z52" /><span className="hbs-nr">00170</span> | zeitraumId | integer | X | — |
| <span className="hbs-g hbs-e2">**nennleistung**</span> | — | object | May | — |
| <span className="hbs-f hbs-e3">[abgabe](/en/bo4e/202610/com/Nennleistung#abgabe)</span> <AhbTabelle pruefid="55617" format="UTILMD" fv="202610" zeile={66} segment="SG4.IDE+24.SG8.SEQ+Z52.SG9.QTY+Z44" /><span className="hbs-nr">00180</span> | Submission of the rated capacity | number (float) | X | — |
| <span className="hbs-f hbs-e3">[aufnahme](/en/bo4e/202610/com/Nennleistung#aufnahme)</span> <AhbTabelle pruefid="55617" format="UTILMD" fv="202610" zeile={62} segment="SG4.IDE+24.SG8.SEQ+Z52.SG9.QTY+Z43" /><span className="hbs-nr">00190</span> | Recording of the rated power | number (float) | X | — |
| <span className="hbs-g hbs-e1">**VERWENDUNGSZEITRAUM** <span className="hbs-liste">[ ]</span> <span className="hbs-pflicht">\*</span></span> | — | object[] | Must | — |
| <span className="hbs-f hbs-e2">[datenqualitaet](/en/bo4e/202610/bo/Verwendungszeitraum#datenqualitaet) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="55617" format="UTILMD" fv="202610" zeile={33} segment="SG4.IDE+24.SG6.RFF+[Z49\|Z53]" /><span className="hbs-nr">00200</span> | Data quality | [Enum Datenqualitaet](/en/bo4e/202610/enum/Datenqualitaet) | Must | — |
| <span className="hbs-w hbs-e3">`ERWARTETE_DATEN`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`IM_SYSTEM_VORHANDENE_DATEN`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`INFORMATIVE_DATEN`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`GUELTIGE_DATEN`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`KEINE_DATEN`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`IM_SYSTEM_KEINE_DATEN_VORHANDEN`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`KEINE_DATEN_ERWARTET`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`DIFFERENZ_DATEN`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`DIFFERENZ_ERWARTETE_DATEN`</span> | — | — | Must | — |
| <span className="hbs-w hbs-e3">`DIFFERENZ_IM_SYSTEM_VORHANDENE_DATEN`</span> | — | — | Must | — |
| <span className="hbs-f hbs-e2">[verwendungAb](/en/bo4e/202610/bo/Verwendungszeitraum#verwendungab) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="55617" format="UTILMD" fv="202610" zeile={40} segment="SG4.IDE+24.SG6.RFF+[Z49\|Z53].DTM+Z25" /><span className="hbs-nr">00210</span> | verwendungAb | string (date-time) | X | — |
| <span className="hbs-f hbs-e2">[verwendungBis](/en/bo4e/202610/bo/Verwendungszeitraum#verwendungbis)</span> <AhbTabelle pruefid="55617" format="UTILMD" fv="202610" zeile={44} segment="SG4.IDE+24.SG6.RFF+[Z49\|Z53].DTM+Z26" /><span className="hbs-nr">00220</span> | verwendungBis | string (date-time) | X | — |
| <span className="hbs-f hbs-e2">[zeitraumId](/en/bo4e/202610/bo/Verwendungszeitraum#zeitraumid) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="55617" format="UTILMD" fv="202610" zeile={33} segment="SG4.IDE+24.SG6.RFF+[Z49\|Z53]" /><span className="hbs-nr">00230</span> | zeitraumId | integer | Must | — |
| <span className="hbs-g hbs-e0">**transaktionsdaten** <span className="hbs-pflicht">\*</span></span> | — | object | Must | — |
| <span className="hbs-f hbs-e1">[dokumentennummer](/en/bo4e/202610/cdoc/Transaktionsdaten#dokumentennummer) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="55617" format="UTILMD" fv="202610" zeile={8} segment="BGM+E03" /><span className="hbs-nr">00240</span> | EDIFACT reference from the BGM segment / BGM | string | X | — |
| <span className="hbs-f hbs-e1">[kategorie](/en/bo4e/202610/cdoc/Transaktionsdaten#kategorie) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="55617" format="UTILMD" fv="202610" zeile={8} segment="BGM+E03" /><span className="hbs-nr">00250</span> | Qualifier from the beginning of the EDIFACT message / BGM | string | X | — |
| <span className="hbs-f hbs-e1">[nachrichtendatum](/en/bo4e/202610/cdoc/Transaktionsdaten#nachrichtendatum) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="55617" format="UTILMD" fv="202610" zeile={11} segment="DTM+137" /><span className="hbs-nr">00260</span> | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| <span className="hbs-f hbs-e1">[nachrichtenreferenznummer](/en/bo4e/202610/cdoc/Transaktionsdaten#nachrichtenreferenznummer) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="55617" format="UTILMD" fv="202610" zeile={0} segment="UNH" /><span className="hbs-nr">00270</span> | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| <span className="hbs-f hbs-e1">[pruefidentifikator](/en/bo4e/202610/cdoc/Transaktionsdaten#pruefidentifikator) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="55617" format="UTILMD" fv="202610" zeile={34} segment="SG4.IDE+24.SG6.RFF+Z13" /><span className="hbs-nr">00280</span> | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| <span className="hbs-f hbs-e1">[transaktionsgrund](/en/bo4e/202610/cdoc/Transaktionsdaten#transaktionsgrund) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="55617" format="UTILMD" fv="202610" zeile={28} segment="SG4.IDE+24.STS+7" /><span className="hbs-nr">00290</span> | The transaction reason describes the business transaction for the category in more detail / UTILMD STS+7++###+ZW4+E03 | string | X | — |
| <span className="hbs-f hbs-e1">[vorgangsnummer](/en/bo4e/202610/cdoc/Transaktionsdaten#vorgangsnummer) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="55617" format="UTILMD" fv="202610" zeile={25} segment="SG4.IDE+24" /><span className="hbs-nr">00300</span> | Number of the transaction / UTILMD UTILTS IDE+24 / INSRPT INVOIC DOC | string | X | — |
| <span className="hbs-g hbs-e1">**absender** <span className="hbs-pflicht">\*</span></span> | — | object | Must | — |
| <span className="hbs-f hbs-e2">[rollencodenummer](/en/bo4e/202610/bo/Marktteilnehmer#rollencodenummer) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="55617" format="UTILMD" fv="202610" zeile={15} segment="SG2.NAD+MS" /><span className="hbs-nr">00310</span> | Specifies the code value of the market role. | string | X | — |
| <span className="hbs-f hbs-e2">[rollencodetyp](/en/bo4e/202610/bo/Marktteilnehmer#rollencodetyp) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="55617" format="UTILMD" fv="202610" zeile={15} segment="SG2.NAD+MS" /><span className="hbs-nr">00320</span> | Indicates the type of the code. | [Enum Rollencodetyp](/en/bo4e/202610/enum/Rollencodetyp) | X | — |
| <span className="hbs-w hbs-e3">`BDEW`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`GS1`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`GLN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`DVGW`</span> | — | — | X | — |
| <span className="hbs-g hbs-e1">**empfaenger** <span className="hbs-pflicht">\*</span></span> | — | object | Must | — |
| <span className="hbs-f hbs-e2">[rollencodenummer](/en/bo4e/202610/bo/Marktteilnehmer#rollencodenummer) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="55617" format="UTILMD" fv="202610" zeile={20} segment="SG2.NAD+MR" /><span className="hbs-nr">00330</span> | Specifies the code value of the market role. | string | X | — |
| <span className="hbs-f hbs-e2">[rollencodetyp](/en/bo4e/202610/bo/Marktteilnehmer#rollencodetyp) <span className="hbs-pflicht">\*</span></span> <AhbTabelle pruefid="55617" format="UTILMD" fv="202610" zeile={20} segment="SG2.NAD+MR" /><span className="hbs-nr">00340</span> | Indicates the type of the code. | [Enum Rollencodetyp](/en/bo4e/202610/enum/Rollencodetyp) | X | — |
| <span className="hbs-w hbs-e3">`BDEW`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`GS1`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`GLN`</span> | — | — | X | — |
| <span className="hbs-w hbs-e3">`DVGW`</span> | — | — | X | — |

</div>

</Handbuchsatz>

## Application handbook (AHB)

<Handbuchsatz>

<div className="maco-tabellenrahmen" data-maco="ahb-tabelle">

| Structure (EDIFACT) | Description | Format | <span className="hbs-p" title="Änderung Daten der TR">55617</span> | Condition |
|---|---|---|---|---|
| <span className="hbs-g hbs-e0">**UNH**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`0062`</span><span className="hbs-nr">00010</span> | Message reference number | — | X | — |
| <span className="hbs-f hbs-e1">`0065 UTILMD`</span><span className="hbs-nr">00020</span> | Grid connection master data | — | X | — |
| <span className="hbs-f hbs-e1">`0052 D`</span><span className="hbs-nr">00030</span> | Draft version | — | X | — |
| <span className="hbs-f hbs-e1">`0054 11A`</span><span className="hbs-nr">00040</span> | Edition 2011 - A | — | X | — |
| <span className="hbs-f hbs-e1">`0051 UN`</span><span className="hbs-nr">00050</span> | UN/CEFACT | — | X | — |
| <span className="hbs-f hbs-e1">`0057 S2.2`</span><span className="hbs-nr">00060</span> | Version number of the underlying BDEW message description | — | X | — |
| <span className="hbs-g hbs-e0">**BGM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1001 E03`</span><span className="hbs-nr">00070</span> | Change notifications | — | X | — |
| <span className="hbs-f hbs-e1">`1004`</span><span className="hbs-nr">00080</span> | Document number | — | X | — |
| <span className="hbs-g hbs-e0">**DTM**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`2005 137`</span><span className="hbs-nr">00090</span> | Document-/ message date/time | — | X | — |
| <span className="hbs-f hbs-e1">`2380`</span><span className="hbs-nr">00100</span> | Date or time or time span, value | — | X | <span className="hbs-marke">[931]</span> <span className="hbs-marke">[494]</span> |
| <span className="hbs-f hbs-e1">`2379 303`</span><span className="hbs-nr">00110</span> | CCYYMMDDHHMM ZZZ | — | X | — |
| <span className="hbs-g hbs-e0">**SG2.NAD**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3035 MS`</span><span className="hbs-nr">00120</span> | Document/message issuer or sender | — | X | — |
| <span className="hbs-f hbs-e1">`3039`</span><span className="hbs-nr">00130</span> | MP-ID | — | X | — |
| <span className="hbs-f hbs-e1">`3055 9`</span><span className="hbs-nr">00140</span> | GS1 | — | X | — |
| <span className="hbs-f hbs-e1">`3055 293`</span><span className="hbs-nr">00150</span> | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| <span className="hbs-g hbs-e0">**SG2.NAD**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3035 MR`</span><span className="hbs-nr">00160</span> | Message recipient | — | X | — |
| <span className="hbs-f hbs-e1">`3039`</span><span className="hbs-nr">00170</span> | MP-ID | — | X | — |
| <span className="hbs-f hbs-e1">`3055 9`</span><span className="hbs-nr">00180</span> | GS1 | — | X | — |
| <span className="hbs-f hbs-e1">`3055 293`</span><span className="hbs-nr">00190</span> | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| <span className="hbs-g hbs-e0">**SG4.IDE**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7495 24`</span><span className="hbs-nr">00200</span> | Transaction | — | X | — |
| <span className="hbs-f hbs-e1">`7402`</span><span className="hbs-nr">00210</span> | Transaction number | — | X | — |
| <span className="hbs-g hbs-e0">**SG4.STS**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`9015 7`</span><span className="hbs-nr">00220</span> | Transaction reason | — | X | — |
| <span className="hbs-f hbs-e1">`9013 ZY0`</span><span className="hbs-nr">00230</span> | Change data of the TR | — | X | — |
| <span className="hbs-g hbs-e0">**SG5.LOC**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`3227 Z20`</span><span className="hbs-nr">00240</span> | Technical resource | — | X | — |
| <span className="hbs-f hbs-e1">`3225`</span><span className="hbs-nr">00250</span> | ID of the technical resource | — | X | <span className="hbs-marke">[922]</span> |
| <span className="hbs-g hbs-e0">**SG6.RFF**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1153 Z13`</span><span className="hbs-nr">00260</span> | Check identifier | — | X | — |
| <span className="hbs-f hbs-e1">`1154 55617`</span><span className="hbs-nr">00270</span> | GPKE / Change data of the TR from NB to LF | — | X | — |
| <span className="hbs-g hbs-e0">**SG6.RFF**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1153 Z49`</span><span className="hbs-nr">00280</span> | Valid data | — | X | <span className="hbs-marke">[1P0..n]</span> |
| <span className="hbs-f hbs-e1">`1153 Z53`</span><span className="hbs-nr">00290</span> | No data | — | X | <span className="hbs-marke">[1P0..n]</span> |
| <span className="hbs-f hbs-e1">`1156`</span><span className="hbs-nr">00300</span> | Time period ID | — | X | <span className="hbs-marke">[914]</span> ∧ <span className="hbs-marke">[937]</span> <span className="hbs-marke">[126]</span> |
| <span className="hbs-g hbs-e0">**SG6.DTM**</span> | — | — | Must | <span className="hbs-marke">[131]</span> ⊻ <span className="hbs-marke">[401]</span> |
| <span className="hbs-f hbs-e1">`2005 Z25`</span><span className="hbs-nr">00310</span> | Data used from | — | X | — |
| <span className="hbs-f hbs-e1">`2380`</span><span className="hbs-nr">00320</span> | Date or time or time span, value | — | X | <span className="hbs-marke">[UB1]</span> |
| <span className="hbs-f hbs-e1">`2379 303`</span><span className="hbs-nr">00330</span> | CCYYMMDDHHMM ZZZ | — | X | — |
| <span className="hbs-g hbs-e0">**SG6.DTM**</span> | — | — | Must | <span className="hbs-marke">[471]</span> |
| <span className="hbs-f hbs-e1">`2005 Z26`</span><span className="hbs-nr">00340</span> | Data used until | — | X | — |
| <span className="hbs-f hbs-e1">`2380`</span><span className="hbs-nr">00350</span> | Date or time or time span, value | — | X | <span className="hbs-marke">[UB1]</span> |
| <span className="hbs-f hbs-e1">`2379 303`</span><span className="hbs-nr">00360</span> | CCYYMMDDHHMM ZZZ | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CAV**</span> | — | — | Must | <span className="hbs-marke">[446]</span> |
| <span className="hbs-g hbs-e0">**SG8.SEQ**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`1229 Z52`</span><span className="hbs-nr">00370</span> | Data of the technical resource | — | X | — |
| <span className="hbs-f hbs-e1">`1050`</span><span className="hbs-nr">00380</span> | Reference to time period ID | — | X | <span className="hbs-marke">[914]</span> ∧ <span className="hbs-marke">[937]</span> <span className="hbs-marke">[22]</span> |
| <span className="hbs-g hbs-e0">**SG8.RFF**</span> | — | — | Should | <span className="hbs-marke">[166]</span> ∧ <span className="hbs-marke">[699]</span> |
| <span className="hbs-f hbs-e1">`1153 Z38`</span><span className="hbs-nr">00390</span> | Controllable resource | — | X | — |
| <span className="hbs-f hbs-e1">`1154`</span><span className="hbs-nr">00400</span> | ID of the controllable resource | — | X | <span className="hbs-marke">[961]</span> |
| <span className="hbs-g hbs-e0">**SG8.RFF**</span> | — | — | Should | <span className="hbs-marke">[166]</span> ∧ <span className="hbs-marke">[700]</span> |
| <span className="hbs-f hbs-e1">`1153 Z32`</span><span className="hbs-nr">00410</span> | Grid location | — | X | — |
| <span className="hbs-f hbs-e1">`1154`</span><span className="hbs-nr">00420</span> | ID of the grid location | — | X | <span className="hbs-marke">[960]</span> |
| <span className="hbs-g hbs-e0">**SG8.RFF**</span> | — | — | Should | <span className="hbs-marke">[166]</span> ∧ <span className="hbs-marke">[447]</span> ∧ <span className="hbs-marke">[701]</span> |
| <span className="hbs-f hbs-e1">`1153 Z20`</span><span className="hbs-nr">00430</span> | Tranche | — | X | — |
| <span className="hbs-f hbs-e1">`1154`</span><span className="hbs-nr">00440</span> | ID of the tranche | — | X | <span className="hbs-marke">[950]</span> |
| <span className="hbs-g hbs-e0">**SG9.QTY**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`6063 Z43`</span><span className="hbs-nr">00450</span> | Rated power (input) | — | X | — |
| <span className="hbs-f hbs-e1">`6060`</span><span className="hbs-nr">00460</span> | Quantity | — | X | — |
| <span className="hbs-f hbs-e1">`6411 KWT`</span><span className="hbs-nr">00470</span> | Kilowatt | — | X | — |
| <span className="hbs-g hbs-e0">**SG9.QTY**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`6063 Z44`</span><span className="hbs-nr">00480</span> | Rated power (output) | — | X | — |
| <span className="hbs-f hbs-e1">`6060`</span><span className="hbs-nr">00490</span> | Quantity | — | X | — |
| <span className="hbs-f hbs-e1">`6411 KWT`</span><span className="hbs-nr">00500</span> | Kilowatt | — | X | — |
| <span className="hbs-g hbs-e0">**SG9.QTY**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`6063 Z42`</span><span className="hbs-nr">00510</span> | Storage capacity | — | X | — |
| <span className="hbs-f hbs-e1">`6060`</span><span className="hbs-nr">00520</span> | Quantity | — | X | — |
| <span className="hbs-f hbs-e1">`6411 KWH`</span><span className="hbs-nr">00530</span> | Kilowatt hour | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7059 Z17`</span><span className="hbs-nr">00540</span> | Type of electricity consumption | — | X | — |
| <span className="hbs-f hbs-e1">`7059 Z50`</span><span className="hbs-nr">00550</span> | Type of electricity generation | — | X | — |
| <span className="hbs-f hbs-e1">`7059 Z56`</span><span className="hbs-nr">00560</span> | Storage | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CAV**</span> | — | — | Must | <span className="hbs-marke">[446]</span> |
| <span className="hbs-f hbs-e1">`7111 Z64`</span><span className="hbs-nr">00570</span> | Power/light | — | X | <span className="hbs-marke">[1P0..1]</span> |
| <span className="hbs-f hbs-e1">`7111 Z65`</span><span className="hbs-nr">00580</span> | Heat/cold | — | X | <span className="hbs-marke">[1P0..1]</span> |
| <span className="hbs-f hbs-e1">`7111 ZE5`</span><span className="hbs-nr">00590</span> | E-mobility | — | X | <span className="hbs-marke">[1P0..1]</span> |
| <span className="hbs-f hbs-e1">`7111 ZA8`</span><span className="hbs-nr">00600</span> | Street lighting | — | X | <span className="hbs-marke">[1P0..1]</span> |
| <span className="hbs-g hbs-e0">**SG10.CAV**</span> | — | — | Must | <span className="hbs-marke">[239]</span> |
| <span className="hbs-f hbs-e1">`7111 Z56`</span><span className="hbs-nr">00610</span> | Storage heating | — | X | — |
| <span className="hbs-f hbs-e1">`7111 Z57`</span><span className="hbs-nr">00620</span> | Heat pump (unspecified) | — | X | — |
| <span className="hbs-f hbs-e1">`7111 Z61`</span><span className="hbs-nr">00630</span> | Direct heating | — | X | — |
| <span className="hbs-f hbs-e1">`7111 ZV5`</span><span className="hbs-nr">00640</span> | Heat pump (heat and cold) | — | X | — |
| <span className="hbs-f hbs-e1">`7111 ZV6`</span><span className="hbs-nr">00650</span> | Heat pump (cold) | — | X | — |
| <span className="hbs-f hbs-e1">`7111 ZV7`</span><span className="hbs-nr">00660</span> | Heat pump (heat) | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CAV**</span> | — | — | Must | <span className="hbs-marke">[95]</span> |
| <span className="hbs-f hbs-e1">`7111 ZE6`</span><span className="hbs-nr">00670</span> | Wallbox | — | X | — |
| <span className="hbs-f hbs-e1">`7111 Z87`</span><span className="hbs-nr">00680</span> | E- mobility charging station | — | X | — |
| <span className="hbs-f hbs-e1">`7111 ZE7`</span><span className="hbs-nr">00690</span> | Charging park | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CAV**</span> | — | — | Must | <span className="hbs-marke">[447]</span> |
| <span className="hbs-f hbs-e1">`7111 ZF5`</span><span className="hbs-nr">00700</span> | Solar | — | X | — |
| <span className="hbs-f hbs-e1">`7111 ZF6`</span><span className="hbs-nr">00710</span> | Wind | — | X | — |
| <span className="hbs-f hbs-e1">`7111 ZG0`</span><span className="hbs-nr">00720</span> | Gas | — | X | — |
| <span className="hbs-f hbs-e1">`7111 ZG1`</span><span className="hbs-nr">00730</span> | Water | — | X | — |
| <span className="hbs-f hbs-e1">`7111 ZG5`</span><span className="hbs-nr">00740</span> | Other generation type | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CAV**</span> | — | — | Must | <span className="hbs-marke">[448]</span> |
| <span className="hbs-f hbs-e1">`7111 ZF7`</span><span className="hbs-nr">00750</span> | Hydrogen storage | — | X | — |
| <span className="hbs-f hbs-e1">`7111 ZF8`</span><span className="hbs-nr">00760</span> | Pumped storage | — | X | — |
| <span className="hbs-f hbs-e1">`7111 ZF9`</span><span className="hbs-nr">00770</span> | Battery storage | — | X | — |
| <span className="hbs-f hbs-e1">`7111 ZG6`</span><span className="hbs-nr">00780</span> | Other storage type | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CAV**</span> | — | — | Must | <span className="hbs-marke">[446]</span> ⊻ <span className="hbs-marke">[448]</span> |
| <span className="hbs-f hbs-e1">`7111 ZG8`</span><span className="hbs-nr">00790</span> | Technical resource is covered by § 14a EnWG | — | X | — |
| <span className="hbs-f hbs-e1">`7111 ZG9`</span><span className="hbs-nr">00800</span> | Technical resource is not covered by § 14a EnWG | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CAV**</span> | — | — | Must | <span className="hbs-marke">[461]</span> |
| <span className="hbs-f hbs-e1">`7111 ZH0`</span><span className="hbs-nr">00810</span> | Commissioning of the TR after 2023 | — | X | — |
| <span className="hbs-f hbs-e1">`7111 ZH1`</span><span className="hbs-nr">00820</span> | Commissioning of the TR before 2024 | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CAV**</span> | — | — | Must | <span className="hbs-marke">[462]</span> |
| <span className="hbs-f hbs-e1">`7111 ZH2`</span><span className="hbs-nr">00830</span> | Option to change to the § 14a EnWG model pursuant to regulatory determination BK6-22-300 still available once | — | X | — |
| <span className="hbs-f hbs-e1">`7111 ZH3`</span><span className="hbs-nr">00840</span> | Option to change to the § 14a EnWG model pursuant to regulatory determination BK6-22-300 not available | — | X | — |
| <span className="hbs-f hbs-e1">`7111 ZH4`</span><span className="hbs-nr">00850</span> | Limited in time under the old § 14a EnWG model until 2028 without option to switch | — | X | — |
| <span className="hbs-f hbs-e1">`7111 ZH5`</span><span className="hbs-nr">00860</span> | Change to the § 14a EnWG model pursuant to regulatory determination BK6-22-300 has been carried out | — | X | — |
| <span className="hbs-g hbs-e0">**SG10.CCI**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`7059 Z68`</span><span className="hbs-nr">00870</span> | Remuneration obligation under EEG or KWKG | — | X | — |
| <span className="hbs-f hbs-e1">`7037 ZH2`</span><span className="hbs-nr">00880</span> | available | — | X | — |
| <span className="hbs-f hbs-e1">`7037 ZH3`</span><span className="hbs-nr">00890</span> | not available | — | X | — |
| <span className="hbs-g hbs-e0">**UNT**</span> | — | — | Must | — |
| <span className="hbs-f hbs-e1">`0074`</span><span className="hbs-nr">00900</span> | Number of segments in a message | — | X | — |
| <span className="hbs-f hbs-e1">`0062`</span><span className="hbs-nr">00910</span> | Message reference number | — | X | — |

</div>

</Handbuchsatz>

### Conditions of this table

The free text of the 27 conditions referenced by the rows above. All conditions of the message type are listed in the [condition index UTILMDS](/en/referenz/202610/ahb-bedingungen/UTILMDS).

<div className="maco-tabellenrahmen">

| Marker | Condition |
|---|---|
| **[22]** | The time period ID from DE1156 of a matching SG6 RFF+Z47/Z48/Z49 (usage period of the data) must be entered |
| **[95]** | If in the same SG10 the CCI+Z17 (type of electricity consumption ) CAV+ZE5 (e-mobility) is present |
| **[126]** | The value resulting from the number of repetitions of the SG6 RFF+Z49/Z53 (usage period of the data: valid data/no data) must be entered. This means: the first SG6 RFF+Z49/Z53 thus has the „1“, the second the „2“, the third the „3“, etc. |
| **[131]** | If this DTM+Z25 (use of the data from) in SG6 RFF (usage peri od of the data) is marked with the time period ID "1" in DE1156, the date in this DE2380 must be the day immediately following DTM+137 DE2380 (message dat e) at 0:00, or a day earlier than that at 0:00 German time |
| **[166]** | If present |
| **[239]** | If in the same SG10 the CCI+Z17 (type of electricity consumption ) is present in the CAV+Z65 (heat/cooling) |
| **[401]** | If this DTM+Z25 (use of data from) is not in the SG6 RFF+Z49/Z53 (usage period of the data: valid data/no data) with time period ID "1" in DE1156, the date must correspond to the DTM+Z26 (use of data until) of the SG6 RFF+Z49/Z53 (usage period of the data: valid data/no data) with the next lower time period ID in DE1156 |
| **[446]** | If in the same SG8 the CCI+Z17 (type of electricity consumption ) is present |
| **[447]** | If in the same SG8 the CCI+Z50 (type of electricity generation ) is present |
| **[448]** | If in the same SG8 the CCI+Z56 (storage) is present |
| **[461]** | If in the same SG10 the CCI (type and use of the technical resource) is present in the CAV+ZG8 (technical resource falls under § 14a EnWG) |
| **[462]** | If in the same SG10 the CCI+Z17 (type of electricity consumption ) is present in the CAV+ZH1 (commissioning of the TR before 2024) |
| **[471]** | If a time period ID is named in DE1156 (time period ID) in the same SG6 RFF+Z49/Z53 (usage period of the data: valid data/no data) which is lower than in another SG6 RFF+Z49/Z53 (usage period of the data: valid data/no data) DE1156 (time period ID) |
| **[494]** | The date stated here must be the point in time at which the document was created, or a point in time before that |
| **[699]** | Note: The ID of the controllable resource via which the technical resource is controlled must be specified |
| **[700]** | Note: The ID of the grid location via which the technical resource is controlled must be specified |
| **[701]** | Note: The Malo ID of the tranche to which the technical resource is assigned must be specified |
| **[914]** | Format: Possible value: &gt; 0 |
| **[922]** | Format: TR-ID |
| **[931]** | Format: ZZZ = +00 |
| **[937]** | Format: no decimal places |
| **[950]** | Format: market location ID |
| **[960]** | Format: Grid location ID |
| **[961]** | Format: SR-ID |
| **[1P0..n]** | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
| **[UB1]** | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |
| **[1P0..1]** | Note: This is the standard package if no condition applies, e.g. in the COM segment. |

</div>

## Example message

<div data-maco="beispielfall" className="maco-beispielfall">

<Beispielnachricht>

```text title="EDIFACT"
UNA:+.? '
UNB+UNOC:3+9900327000009:500+9903729000007:500+{{date}}:{{time}}+DARJHUFRPVVDMM'
UNH+DAGMFJRWNDCGFI+UTILMD:D:11A:UN:S2.2'
BGM+E03+DA542411080929419903323000007156920'
DTM+137:202610021100?+00:303'
NAD+MS+9900327000009::293'
NAD+MR+9903729000007::293'
IDE+24+24062416225400000000000102159662011'
STS+7++ZY0'
LOC+Z20+D417MLM8164'
RFF+Z13:55617'
RFF+Z49::1'
DTM+Z25:202606232200?+00:303'
DTM+Z26:202607232200?+00:303'
RFF+Z49::2'
DTM+Z25:202607232200?+00:303'
SEQ+Z52+1'
RFF+Z38:C816417ST77'
RFF+Z32:E1688117482'
QTY+Z44:100:KWT'
CCI+Z50'
CAV+ZF5'
CCI+Z68++ZH2'
SEQ+Z52+2'
RFF+Z38:C816417ST77'
RFF+Z32:E1688117482'
QTY+Z44:100:KWT'
CCI+Z50'
CAV+ZF5'
CCI+Z68++ZH2'
UNT+29+DAGMFJRWNDCGFI'
UNZ+1+DARJHUFRPVVDMM'
```

```json title="BO4E-JSON"
[
  {
    "businessKey": "<businessKey>",
    "processDate": null,
    "dataSource": "OUTBOUND",
    "version": 1,
    "edifactVersion": 202610,
    "data": {
      "stammdaten": {
        "VERWENDUNGSZEITRAUM": [
          {
            "boTyp": "VERWENDUNGSZEITRAUM",
            "versionStruktur": "1",
            "zeitraumId": 1,
            "datenqualitaet": "GUELTIGE_DATEN",
            "verwendungAb": "2026-06-23T22:00:00Z",
            "verwendungBis": "2026-07-23T22:00:00Z"
          },
          {
            "boTyp": "VERWENDUNGSZEITRAUM",
            "versionStruktur": "1",
            "zeitraumId": 2,
            "datenqualitaet": "GUELTIGE_DATEN",
            "verwendungAb": "2026-07-23T22:00:00Z"
          }
        ],
        "TECHNISCHE_RESSOURCE": [
          {
            "boTyp": "TECHNISCHE_RESSOURCE",
            "versionStruktur": "1",
            "ressourcenId": "D417MLM8164",
            "sparte": "STROM",
            "gueltigkeitszeitraum": {
              "zeitraumId": 1,
              "startdatum": "2026-06-23T22:00:00Z",
              "enddatum": "2026-07-23T22:00:00Z"
            },
            "datenqualitaet": "GUELTIGE_DATEN",
            "referenzNetzlokation": "E1688117482",
            "referenzSteuerbareRessource": "C816417ST77",
            "nennleistung": {
              "abgabe": 100
            },
            "erzeugungsart": "SOLAR",
            "art": "STROMERZEUGUNG",
            "verguetungsverpflichtung": true
          },
          {
            "boTyp": "TECHNISCHE_RESSOURCE",
            "versionStruktur": "1",
            "ressourcenId": "D417MLM8164",
            "sparte": "STROM",
            "gueltigkeitszeitraum": {
              "zeitraumId": 2,
              "startdatum": "2026-07-23T22:00:00Z"
            },
            "datenqualitaet": "GUELTIGE_DATEN",
            "referenzNetzlokation": "E1688117482",
            "referenzSteuerbareRessource": "C816417ST77",
            "nennleistung": {
              "abgabe": 100
            },
            "erzeugungsart": "SOLAR",
            "art": "STROMERZEUGUNG",
            "verguetungsverpflichtung": true
          }
        ],
        "STEUERBARE_RESSOURCE": [
          {
            "boTyp": "STEUERBARE_RESSOURCE",
            "versionStruktur": "1",
            "ressourcenId": "C816417ST77",
            "sparte": "STROM"
          }
        ]
      },
      "transaktionsdaten": {
        "datenaustauschreferenz": "DARJHUFRPVVDMM",
        "sparte": "STROM",
        "transaktionsgrund": "ZY0",
        "vorgangsnummer": "24062416225400000000000102159662011",
        "pruefidentifikator": "55617",
        "absender": {
          "boTyp": "MARKTTEILNEHMER",
          "versionStruktur": "1",
          "rollencodenummer": "9900327000009",
          "rollencodetyp": "BDEW"
        },
        "empfaenger": {
          "boTyp": "MARKTTEILNEHMER",
          "versionStruktur": "1",
          "rollencodenummer": "9903729000007",
          "rollencodetyp": "BDEW"
        },
        "dokumentennummer": "DA542411080929419903323000007156920",
        "kategorie": "E03",
        "nachrichtendatum": "2026-10-02T11:00:00Z",
        "nachrichtenreferenznummer": "DAGMFJRWNDCGFI"
      },
      "zusatzdaten": {}
    }
  }
]
```

</Beispielnachricht>

*Source: [`1.edi`](https://github.com/conuti-gmbh/maco-edi-testfiles/blob/main/inbound/v202610/utilmd/55617/1.edi) · [`1.json`](https://github.com/conuti-gmbh/maco-edi-testfiles/blob/main/outbound/v202610/utilmd/55617/1.json)*

<Testdateien edi="/testdaten/202610/utilmd/55617/1.edi" json="/testdaten/202610/utilmd/55617/1.json" />

</div>

## Belongs to these role views

The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are **LF**, **NB**, **MSB** and **ÜNB**.

<div className="maco-tabellenrahmen">

| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | [Master data change initiated by the NB (responsible)](/en/prozessdoku/202610/LF/GPKE-Teil4-stammdatenaenderung-vom-nb-verantwortlich-ausgehend) | GPKE part 4 | Electricity | Step 1 |
| NB | NB | [Master data change initiated by the NB (responsible)](/en/prozessdoku/202610/NB/GPKE-Teil4-stammdatenaenderung-vom-nb-verantwortlich-ausgehend) | GPKE part 4 | Electricity | Step 1 |
| NB | NBA | [Supplementary data on the location bundle from NBA to NBN](/en/prozessdoku/202610/NB--NBA/awh-netzbetreiberwechsel-erganzende-daten-zum-lokationsbundel-von-nba-an-nbn) | AWH grid operator change | Electricity | Step 1 |
| NB | NBN | [Supplementary data on the location bundle from NBA to NBN](/en/prozessdoku/202610/NB--NBN/awh-netzbetreiberwechsel-erganzende-daten-zum-lokationsbundel-von-nba-an-nbn) | AWH grid operator change | Electricity | Step 1 |
| MSB | MSB | [Master data change initiated by the NB (responsible)](/en/prozessdoku/202610/MSB/GPKE-Teil4-stammdatenaenderung-vom-nb-verantwortlich-ausgehend) | GPKE part 4 | Electricity | Step 1 |
| ÜNB | ÜNB | [Master data change initiated by the NB (responsible)](/en/prozessdoku/202610/UENB/GPKE-Teil4-stammdatenaenderung-vom-nb-verantwortlich-ausgehend) | GPKE part 4 | Electricity | Step 1 |

</div>

## Business classification

<div className="maco-tabellenrahmen">

| Attribute | Value |
|---|---|
| Use case (AHB) | Change data of the TR |
| AHB | UTILMD AHB electricity |
| Transmission channel | AS4 |

</div>

:::caution{title="This check identifier is used in 2 contexts"}

Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.

:::

<div className="maco-tabellenrahmen">

| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| GPKE part 4 | Master data change initiated by the NB (responsible) | NB → LF | Change from the NB to LF |
| AWH grid operator change | Supplementary data on the location bundle from NBA to NBN | NB (corresponds to NBA) → NB (corresponds to NBN) | supplementary data on the location bundle |

</div>

## Transaction and responses

**Role of this check identifier: request.** Basis: the transaction data carry neither `antwortstatus` nor `antwortstatusCodeliste`, and neither the title nor the action of the Prüfi table begins with “response” or “response message”.

**Responses:** No response of this format version names this check identifier as a reference — neither explicitly in the Prüfi table nor via the step sequence. That does not mean there is none; it means that the sources do not record one.

**Check identifiers of the same AHB table:** No other check identifier of message type UTILMDS has the same row structure in this version.

<Hinweisbereich>

An **\*** after a field or group name marks a **mandatory field** or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.

The status column carries two vocabularies because the manual answers two questions: on a **group row**, *Muss*, *Soll* or *Kann* states whether the EDIFACT segment must be present; on a **field row**, *X* states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.

For this check identifier, the application handbook lists **122 rows**. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.

The **Condition** column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.

The test data contains one transaction for this check identifier under the message type `utilmd`. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.

:::note{title="Placeholder from the test data set"}

The test data set carries placeholders instead of valid values: `{{date}}` and `{{time}}` in the UNB interchange envelope of every EDIFACT file. **The page replaces these on call with the current date and the current time** — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.

`<businessKey>` stays in place. It is not a time value, and an invented key would look like a valid one.

:::

</Hinweisbereich>