Check identifier 37005 — Communication details of the ÜNB Electricity
Check identifier 37005 · EDIFACT message type PARTIN · Format version 202610
This page is derived from the application handbook
The MACO APP does not carry this check identifier. The complete Prüfi pages of this level are produced from the specifications of the application — one class in the templater per check identifier — and that is where the assignment to the business objects (BO4E) comes from: which object carries which field of the message.
The catalogue of the application handbook is the larger set. This page therefore shows what the handbook itself provides — use case, process context and the AHB field list with its conditions. A data structure according to BO4E is not shown, and not because there is none, but because the application does not form one for this check identifier.
All check identifiers in this situation — and the corresponding figures — are listed by the overview of this version.
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 37005 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 PARTIN00020 | Partner master data | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 20B00040 | Edition 2020 - B | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 1.100060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 1000070 | Partner master data | — | X | — |
100400080 | Document number | — | X | — |
1373 1100090 | Document not available | — | — | S [9] |
| DTM | — | — | Must | — |
2005 13700100 | Document-/message date/time | — | X | — |
238000110 | Date or time or time span, value | — | X | [931][494] |
2379 30300120 | CCYYMMDDHHMMZZZ | — | X | — |
| SG1.RFF | — | — | Must | — |
1153 Z1300130 | Check identifier | — | X | — |
1154 3700500140 | Communication details of the ÜNB electricity | — | X | — |
| SG1.RFF | — | — | Must | — |
1153 AGK00150 | Application reference number | — | X | — |
105600160 | Version number | — | X | [908][505] |
| SG1.DTM | — | — | Should | [4] |
2005 15700170 | Validity, start date | — | X | — |
238000180 | Date or time or time span, value | — | X | [UB1] |
2379 30300190 | CCYYMMDDHHMMZZZ | — | X | — |
| SG1.RFF | — | — | Must | — |
1153 ACW00200 | Reference number of a preceding message | — | X | — |
105600210 | Version number | — | X | [908] |
| SG2.NAD | — | — | Must | — |
3035 MS00220 | Document-/message sender or sender | — | X | — |
303900230 | MP-ID | — | X | [1] |
3055 900240 | GS1 | — | X | — |
3055 29300250 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MR00260 | Message recipient | — | X | — |
303900270 | MP-ID | — | X | [1] |
3055 900280 | GS1 | — | X | — |
3055 29300290 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| UNS | — | — | Must | — |
0081 D00300 | Separation of header and detail section | — | X | — |
| SG4.NAD | — | — | Must | — |
3035 Z3100310 | Transmission system operator (TSO) | — | X | — |
303600320 | Name | — | X | [506] |
3045 Z0200330 | Structure of the company name | — | X | — |
304200340 | Street and house number or PO box | — | X | [506] |
316400350 | City | — | X | [506] |
325100360 | Postal code | — | — | M [2] ∧ [506] S [3] ∧ [506] |
320700370 | Country name, code | — | X | [506] |
| SG4.FII | — | — | Must | — |
3035 BK00380 | Credit institution | — | X | — |
319400390 | IBAN | — | X | — |
319200400 | Name of the account holder | — | X | — |
319200410 | Name of the account holder | — | — | — |
343300420 | BIC | — | X | — |
343200430 | Name of the credit institution | — | X | — |
| SG4.FTX | — | — | Must | — |
4451 Z1300440 | Website | — | X | — |
444000450 | Website | — | X | — |
| SG4.FTX | — | — | Should | [3] |
4451 Z1500460 | Court and commercial register number | — | X | — |
444000470 | Court | — | X | — |
444000480 | Commercial register number | — | X | — |
| SG6.RFF | — | — | Must | — |
1153 VA00490 | Value added tax number | — | X | [2P0..1] ⊻ [3P1..1] |
1153 FC00500 | Tax number | — | X | [2P0..1] |
115400510 | Reference, identification | — | X | — |
| SG6.RFF | — | — | May | — |
1153 Z2500520 | Fax number | — | X | — |
115400530 | Fax number | — | X | [940] |
| SG12.CCI | — | — | Must | — |
7059 Z4000540 | Availability of the company | — | X | — |
| SG12.DTM | — | — | Must | — |
2005 Z3600550 | Availability Monday | — | X | [1P1..1] |
2005 Z3700560 | Availability Tuesday | — | X | [1P1..1] |
2005 Z3800570 | Availability Wednesday | — | X | [1P1..1] |
2005 Z3900580 | Availability Thursday | — | X | [1P1..1] |
2005 Z4000590 | Availability Friday | — | X | [1P1..1] |
2005 Z4100600 | Lunch break (= exclusion of availability) | — | X | [1P0..1] |
238000610 | Date or time or time span, value | — | X | [503] |
2379 50100620 | HHMMHHMM | — | X | — |
| SG4.NAD | — | — | Must | — |
3035 Z1000630 | Contact person transmission channel / data exchange | — | X | — |
303600640 | Name | — | X | [500] |
3045 Z0200650 | Structure of the company name | — | X | — |
304200660 | Street and house number or PO box | — | X | — |
316400670 | City | — | X | — |
325100680 | Postal code | — | — | M [2] S [3] |
320700690 | Country name, code | — | X | — |
| SG7.CTA | — | — | Must | — |
3139 IC00700 | Information contact | — | X | — |
341200710 | Name of the organisational unit | — | X | [501] |
| SG7.COM | — | — | Must | — |
314800720 | Number / address | — | X | (([939][6]) ⊻ ([940][8])) ∧ [502] |
3155 EM00730 | Electronic mail | — | X | [1P1..1] |
3155 TE00740 | Telephone | — | X | [1P1..1] |
3155 FX00750 | Fax number | — | X | [1P0..1] |
| SG4.NAD | — | — | Must | — |
3035 Z1100760 | Contact person framework agreements | — | X | — |
303600770 | Name | — | X | [500] |
3045 Z0200780 | Structure of the company name | — | X | — |
304200790 | Street and house number or PO box | — | X | — |
316400800 | City | — | X | — |
325100810 | Postal code | — | — | M [2] S [3] |
320700820 | Country name, code | — | X | — |
| SG7.CTA | — | — | Must | — |
3139 IC00830 | Information contact | — | X | — |
341200840 | Name of the organisational unit | — | X | [501] |
| SG7.COM | — | — | Must | — |
314800850 | Number / address | — | X | (([939][6]) ⊻ ([940][8])) ∧ [502] |
3155 EM00860 | Electronic mail | — | X | [1P1..1] |
3155 TE00870 | Telephone | — | X | [1P1..1] |
3155 FX00880 | Fax number | — | X | [1P0..1] |
| SG4.NAD | — | — | Must | — |
3035 Z1400890 | Contact person master data processes | — | X | — |
303600900 | Name | — | X | [500] |
3045 Z0200910 | Structure of the company name | — | X | — |
304200920 | Street and house number or PO box | — | X | — |
316400930 | City | — | X | — |
325100940 | Postal code | — | — | M [2] S [3] |
320700950 | Country name, code | — | X | — |
| SG7.CTA | — | — | Must | — |
3139 IC00960 | Information contact | — | X | — |
341200970 | Name of the organisational unit | — | X | [501] |
| SG7.COM | — | — | Must | — |
314800980 | Number / address | — | X | (([939][6]) ⊻ ([940][8])) ∧ [502] |
3155 EM00990 | Electronic mail | — | X | [1P1..1] |
3155 TE01000 | Telephone | — | X | [1P1..1] |
3155 FX01010 | Fax number | — | X | [1P0..1] |
| SG4.NAD | — | — | Must | — |
3035 Z1801020 | Contact person MMMA processes | — | X | — |
303601030 | Name | — | X | [500] |
3045 Z0201040 | Structure of the company name | — | X | — |
304201050 | Street and house number or PO box | — | X | — |
316401060 | City | — | X | — |
325101070 | Postal code | — | — | M [2] S [3] |
320701080 | Country name, code | — | X | — |
| SG7.CTA | — | — | Must | — |
3139 IC01090 | Information contact | — | X | — |
341201100 | Name of the organisational unit | — | X | [501] |
| SG7.COM | — | — | Must | — |
314801110 | Number / address | — | X | (([939][6]) ⊻ ([940][8])) ∧ [502] |
3155 EM01120 | Electronic mail | — | X | [1P1..1] |
3155 TE01130 | Telephone | — | X | [1P1..1] |
3155 FX01140 | Fax number | — | X | [1P0..1] |
| SG4.NAD | — | — | Must | — |
3035 Z1901150 | Contact person transaction data | — | X | — |
303601160 | Name | — | X | [500] |
3045 Z0201170 | Structure of the company name | — | X | — |
304201180 | Street and house number or PO box | — | X | — |
316401190 | City | — | X | — |
325101200 | Postal code | — | — | M [2] S [3] |
320701210 | Country name, code | — | X | — |
| SG7.CTA | — | — | Must | — |
3139 IC01220 | Information contact | — | X | — |
341201230 | Name of the organisational unit | — | X | [501] |
| SG7.COM | — | — | Must | — |
314801240 | Number / address | — | X | (([939][6]) ⊻ ([940][8])) ∧ [502] |
3155 EM01250 | Electronic mail | — | X | [1P1..1] |
3155 TE01260 | Telephone | — | X | [1P1..1] |
3155 FX01270 | Fax number | — | X | [1P0..1] |
| SG4.NAD | — | — | Must | — |
3035 Z2001280 | Contact person disconnection/reconnection processes | — | X | — |
303601290 | Name | — | X | [500] |
3045 Z0201300 | Structure of the company name | — | X | — |
304201310 | Street and house number or PO box | — | X | — |
316401320 | City | — | X | — |
325101330 | Postal code | — | — | M [2] S [3] |
320701340 | Country name, code | — | X | — |
| SG7.CTA | — | — | Must | — |
3139 IC01350 | Information contact | — | X | — |
341201360 | Name of the organisational unit | — | X | [501] |
| SG7.COM | — | — | Must | — |
314801370 | Number / address | — | X | (([939][6]) ⊻ ([940][8])) ∧ [502] |
3155 EM01380 | Electronic mail | — | X | [1P1..1] |
3155 TE01390 | Telephone | — | X | [1P1..1] |
3155 FX01400 | Fax number | — | X | [1P0..1] |
| SG4.NAD | — | — | Must | — |
3035 Z2101410 | Contact person balancing processes / balancing group management | — | X | — |
303601420 | Name | — | X | [500] |
3045 Z0201430 | Structure of the company name | — | X | — |
304201440 | Street and house number or PO box | — | X | — |
316401450 | City | — | X | — |
325101460 | Postal code | — | — | M [2] S [3] |
320701470 | Country name, code | — | X | — |
| SG7.CTA | — | — | Must | — |
3139 IC01480 | Information contact | — | X | — |
341201490 | Name of the organisational unit | — | X | [501] |
| SG7.COM | — | — | Must | — |
314801500 | Number / address | — | X | (([939][6]) ⊻ ([940][8])) ∧ [502] |
3155 EM01510 | Electronic mail | — | X | [1P1..1] |
3155 TE01520 | Telephone | — | X | [1P1..1] |
3155 FX01530 | Fax number | — | X | [1P0..1] |
| UNT | — | — | Must | — |
007401540 | Number of segments in a message | — | X | — |
006201550 | Message reference number | — | X | — |
Conditions of this table
The free text of the 23 conditions referenced by the rows above. All conditions of the message type are listed in the condition index PARTIN.
| Marker | Condition |
|---|---|
| [1] | Only MP-ID from the electricity division |
| [2] | If the code in DE3207 contains an "X" in the column "PLZ present" of the "EDI@Energy code list of European country codes" |
| [3] | if present |
| [4] | If a previous version is present |
| [6] | if the code EM is present in DE3155 in the same COM |
| [8] | if the code TE / FX is present in DE3155 in the same COM |
| [9] | If the communication details of the sender are no longer active. |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that. |
| [500] | Note: The company name of a service provider or the identical company name from SG4 NAD+SU / DDM / DEB / Z31 / Z34 / Z35 / Z36 / Z71 may be entered. |
| [501] | Note: No name of a natural person may be transmitted; instead, the organizational unit within the company is to be named. |
| [502] | Note: Only one piece of information may be transmitted in DE3148 |
| [503] | Note: Indication is given in German statutory time |
| [505] | If a previous version (RFF+ACW) is specified, the value in this DE1056 must be at least 1 higher than the value from DE1056 of the previous version (RFF+ACW). |
| [506] | Note: The data element is to be filled in such a way that its content complies with the requirements of the USt. Act, so that the recipient can use this data in a INVOIC. |
| [908] | Format: possible values: 1 to n |
| [931] | Format: ZZZ = +00 |
| [939] | Format: the character string must contain the characters @ and . |
| [940] | Format: the character string must begin with the character + and may only be followed by digits |
| [UB1] | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |
| [2P0..1] | [11] If SG4 NAD+SU (supplier) DE3207 with code „DE“ present [12] If SG4 NAD+DDM (grid operator) DE3207 with code „DE“ present [13] If SG4 NAD+DEB (metering point operator) DE3207 with code „DE“ present [27] If SG4 NAD+Z31 (transmission system operator (TSO)) DE3207 with code „DE“ present [28] If SG4 NAD+Z34 (balancing group coordinator) DE3207 with code „DE“ present [29] If SG4 NAD+Z35 (balance responsible party) DE3207 with code „DE“ present [30] If SG4 NAD+Z36 (energy service provider) DE3207 with code „DE“ present [43] If SG4 NAD+Z71 (market area manager) DE3207 with code „DE“ present |
| [3P1..1] | [14] If in SG4 NAD+SU (supplier) DE3207 the code „DE“ is not present [15] If in SG4 NAD+DDM (grid operator) DE3207 the code „DE“ is not present [16] If in SG4 NAD+DEB (metering point operator) DE3207 the code „DE“ is not present [31] If SG4 NAD+Z31 (transmission system operator (TSO)) DE3207 with code „DE“ not present [32] If SG4 NAD+Z34 (balancing group coordinator) DE3207 with code „DE“ not present [33] If SG4 NAD+Z35 (balance responsible party) DE3207 with code „DE“ not present [34] If SG4 NAD+Z36 (energy service provider) DE3207 with code „DE“ not present [44] If SG4 NAD+Z71 (market area manager) DE3207 with code „DE“ not present |
| [1P1..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF and NB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | Transmission of information | GPKE part 4 | Electricity | Step 1 |
| NB | NB | Transmission of information | GPKE part 4 | Electricity | Step 1 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Communication details of the ÜNB electricity |
| AHB | PARTIN AHB |
| Transmission channel | AS4 |
This check identifier is used in 10 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| GPKE part 4 | Transmission of information | ÜNB → NB | Information |
| GPKE part 4 | Transmission of information | ÜNB → LF | Information |
| GPKE part 4 | Transmission of information | ÜNB → BKV | Information |
| GPKE part 4 | Transmission of information | ÜNB → BIKO | Information |
| GPKE part 4 | Transmission of information | ÜNB → MSB | Information |
| GPKE part 4 | Transmission of information | ÜNB → NB | Information |
| GPKE part 4 | Transmission of information | ÜNB → LF | Information |
| GPKE part 4 | Transmission of information | ÜNB → BKV | Information |
| GPKE part 4 | Transmission of information | ÜNB → BIKO | Information |
| GPKE part 4 | Transmission of information | ÜNB → MSB | Information |
Notes on this page
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 195 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.