Check identifier 25009 — Transmission of a rolled-out power curve definition
Check identifier 25009 · EDIFACT message type UTILTS · Format version 202610
Data structure
| Structure (BO4E) | Description | Format | 25009 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| LEISTUNGSKURVENDEFINITION [ ] * | — | object[] | Must | — |
| beginndatum * 00010 | beginndatum | string (date-time) | X | — |
| code * 00020 | code | string | X | — |
| endedatum 00030 | endedatum | string (date-time) | X | — |
| version * 00040 | version | string (date-time) | X | — |
| leistungskurven [ ] * | — | object[] | Must | — |
| aenderungszeitpunkt * 00050 | Time of change | string (date-time) | X | — |
| haeufigkeit 00060 | HaeufigkeitLeistungskurve | Enum HaeufigkeitLeistungskurve | X | — |
EINMALIG | — | — | X | — |
JAEHRLICH | — | — | X | — |
| schwellwert * | — | object | Must | — |
| obererSchwellwert * 00070 | obererSchwellwert | number (float) | X | — |
| transaktionsdaten * | — | object | Must | — |
| anfrageReferenz 00080 | Application number / RFF+AGI | string | X | — |
| dokumentennummer * 00090 | EDIFACT reference from the BGM segment / BGM | string | X | — |
| nachrichtendatum * 00100 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenreferenznummer * 00110 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 00120 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| vorgangsnummer * 00130 | Number of the transaction / UTILMD UTILTS IDE+24 / INSRPT INVOIC DOC | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 00140 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00150 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 00160 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00170 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 25009 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 UTILTS00020 | Grid usage times message | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 18A00040 | Edition 2018 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 1.1e00060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 Z8100070 | Rolled-out power curve definition | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931][494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00120 | Document-/message sender or sender | — | X | — |
303900130 | MP-ID | — | X | [1] |
3055 900140 | GS1 | — | X | — |
3055 29300150 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MR00160 | Message recipient | — | X | — |
303900170 | MP-ID | — | X | [1] |
3055 900180 | GS1 | — | X | — |
3055 29300190 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG5.IDE | — | — | Must | — |
7495 2400200 | Transaction | — | X | — |
740200210 | Transaction number | — | X | — |
| SG5.LOC | — | — | Must | — |
3227 Z0900220 | Code of the definition | — | X | — |
322500230 | Code of the definition | — | X | [526] |
| SG5.DTM | — | — | Must | — |
2005 Z3400240 | Start of validity | — | X | — |
238000250 | Date or time or time span, value | — | X | [931] ∧ [947] |
2379 30300260 | CCYYMMDDHHMMZZZ | — | X | — |
| SG5.DTM | — | — | Must | [48] Should [49] ∧ [37] |
2005 Z3500270 | End of validity | — | X | — |
238000280 | Date or time or time span, value | — | X | [931] ∧ [947] [30] |
2379 30300290 | CCYYMMDDHHMMZZZ | — | X | — |
| SG5.DTM | — | — | Must | — |
2005 29300300 | Completion date/time | — | X | — |
238000310 | Date or time or time span, value | — | X | [931] |
2379 30400320 | CCYYMMDDHHMMSSZZZ | — | X | — |
| SG6.RFF | — | — | Must | — |
1153 Z1300330 | Check identifier | — | X | — |
1154 2500900340 | Rolled-out power curve definition | — | X | — |
| SG6.RFF | — | — | Must | — |
1153 AGI00350 | Application number | — | X | — |
115400360 | Reference, identification | — | X | [504] |
| SG8.SEQ | — | — | Must | — |
1229 Z7400370 | Rolled-out power curve definition | — | X | — |
| SG8.DTM | — | — | Must | — |
2005 Z4500380 | Point in time of the power curve change | — | X | — |
238000390 | Date or time or time span, value | — | X | ([931] [31] ∧ [32] ∧ [33]) ⊻ (([964] ∧ [965] [34]) ∧ [507]) |
2379 30300400 | CCYYMMDDHHMMZZZ | — | — | [9P0..1] |
2379 40100410 | HHMM | — | — | [10P0..1] |
| SG11.QTY | — | — | Must | — |
6063 Z4000420 | upper threshold | — | X | — |
606000430 | Quantity specification in % | — | X | [930] ∧ [963] |
6411 P100440 | Percent | — | X | — |
| UNT | — | — | Must | — |
007400450 | Number of segments in a message | — | X | — |
006200460 | Message reference number | — | X | — |
Conditions of this table
The free text of the 21 conditions referenced by the rows above. All conditions of the message type are listed in the condition index UTILTS.
| Marker | Condition |
|---|---|
| [1] | Only MP-ID from the electricity division |
| [30] | The value of CCYY in this DE must be exactly one higher than the value CCYY of the SG5 DTM+Z34 (start of validity) DE2380 |
| [31] | If code 303 is present in DE2379 of this segment |
| [32] | The point in time in this DE must be ≥ the point in time from DE2380 of the start of validity of the rolled-out definition (SG5 DTM+Z34) |
| [33] | The point in time in this DE must be ≤ the point in time from DE2380 of the end of validity of the rolled-out definition (SG5 DTM+Z35) |
| [34] | If code 401 is present in DE2379 of this segment |
| [37] | If an end of validity can already be specified. |
| [48] | If the code 303 is present in DE2379 in SG8 SEQ+Z74 DTM+Z45 (time of the power curve change) |
| [49] | If the code 401 is present in DE2379 in SG8 SEQ+Z74 DTM+Z45 (time of the power curve change) |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that. |
| [504] | Note: Value from BGM+Z55 DE1004 of the ORDERS with which the complaint regarding a definition was made |
| [507] | Note: The time must be specified according to German statutory time |
| [526] | Note: The code of a power curve definition must be specified |
| [930] | Format: max. 2 decimal places |
| [931] | Format: ZZZ = +00 |
| [947] | Format: MMDDHHMM = 12312300 |
| [963] | Format: Possible value: ≤ 100 |
| [964] | Format: HHMM ≥ 0000 |
| [965] | Format: HHMM ≤ 2359 |
| [9P0..1] | [50] The same code must be specified in every DE2379 of this DTM segment within a IDE+24 (transaction) [528] Note: This code must be specified if the definition is transmitted annually |
| [10P0..1] | [50] The same code must be specified in every DE2379 of this DTM segment within a IDE+24 (transaction) [527] Note: This code must be specified if the definition is transmitted once only |
Example message
UNA:+.? '
UNB+UNOC:3+9900259000002:500+9903111000003:500+{{date}}:{{time}}+M0GA80AJ'
UNH+M0291ML2+UTILTS:D:18A:UN:1.1e'
BGM+Z81+M0B9Z35W'
DTM+137:202610011100?+00:303'
NAD+MS+9900259000002::293'
NAD+MR+9903111000003::293'
IDE+24+Vorgang6'
LOC+Z09+AL'
DTM+Z34:202312312300?+00:303'
DTM+Z35:202412312300?+00:303'
DTM+293:20240801134518?+00:304'
RFF+Z13:25009'
SEQ+Z74'
DTM+Z45:202412142300?+00:303'
QTY+Z40:20:P1'
UNT+15+M0291ML2'
UNZ+1+M0GA80AJ'[1 item
{6 fields
"data": {3 fields
"stammdaten": {1 field
"LEISTUNGSKURVENDEFINITION": [1 item
{7 fields
"leistungskurven": [1 item
{3 fields
"schwellwert": {1 field
"transaktionsdaten": {10 fields
"absender": {4 fields
"empfaenger": {4 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF, NB and MSB.
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Transmission of a rolled-out power curve definition |
| AHB | UTILTS AHB |
| Transmission channel | AS4 |
This check identifier is used in 4 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| GPKE part 3 | Transmission of a definition of the NB by the NB | NB → LF | Definition of the NB |
| GPKE part 3 | Transmission of a definition of the NB by the NB | NB → MSB | Definition of the NB |
| GPKE part 3 | Transmission of a definition of the LF by the LF | LF → NB | Definition of the LF |
| GPKE part 3 | Transmission of a definition of the LF by the LF | LF → MSB | Definition of the LF |
Transaction and responses
Role of this check identifier: request. Basis: the transaction data carry neither antwortstatus nor antwortstatusCodeliste, and neither the title nor the action of the Prüfi table begins with “response” or “response message”.
Responses: No response of this format version names this check identifier as a reference — neither explicitly in the Prüfi table nor via the step sequence. That does not mean there is none; it means that the sources do not record one.
Check identifiers of the same AHB table: No other check identifier of message type UTILTS has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 62 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains one transaction for this check identifier under the message type utilts. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.