Check identifier 23001 — Fault report
Check identifier 23001 · EDIFACT message type INSRPT · Format version 202610
Data structure
| Structure (BO4E) | Description | Format | 23001 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| STATUSMITTEILUNG [ ] * | — | object[] | Must | — |
| positionsdaten [ ] * | — | object[] | Must | — |
| auftragsstatus * 00010 | Order status | Enum Auftragsstatus | X | — |
GESCHEITERT | — | — | X | — |
ERFOLGREICH | — | — | X | — |
LIEFERUNG_GEPLANT | — | — | X | — |
GEPLANT | — | — | X | — |
ZUGESTIMMT | — | — | X | — |
WIDERSPROCHEN | — | — | X | — |
STOERUNGSFREI | — | — | X | — |
GESTOERT | — | — | X | — |
FESTGESTELLTE_STOERUNG | — | — | X | — |
VERMUTETE_STOERUNG | — | — | X | — |
ABGELEHNT | — | — | X | — |
BEENDET | — | — | X | — |
ANTWORT_DRITTER | — | — | X | — |
BESTAETIGT | — | — | X | — |
UMGESETZT | — | — | X | — |
ENFG_STROMSPEICHER_UND_VERLUSTENERGIE | — | — | X | — |
ENFG_ELEKTRISCH_ANGETRIEBENE_WAERMEPUMPEN | — | — | X | — |
ENFG_UMLAGEERHEBUNG_BEI_ANLAGEN_ZUR_VERSTROMUNG_VON_KUPPELGASEN | — | — | X | — |
ENFG_HERSTELLUNG_VON_GRUENEN_WASSERSTOFF | — | — | X | — |
ENFG_STROMKOSTENINTENSIVE_UNTERNEHMEN | — | — | X | — |
ENFG_HERSTELLUNG_VON_WASSERSTOFF_IN_STROMKOSTENINTENSIVEN_UNTERNEHMEN | — | — | X | — |
ENFG_SCHIENENBAHNEN | — | — | X | — |
ENFG_ELEKTRISCHE_BETRIEBENE_BUSSEN_IM_LINIENVERKEHR | — | — | X | — |
ENFG_LANDSTROMANLAGEN | — | — | X | — |
AENDERUNG_DER_DATEN | — | — | X | — |
KEINE_AENDERUNG_DER_DATEN | — | — | X | — |
ZEITREIHE_AKZEPTIERT | — | — | X | — |
ZEITREIHE_NICHT_AKZEPTIERT | — | — | X | — |
| lokationsId * 00020 | lokationsId | string | X | — |
| positionsnummer * 00030 | positionsnummer | integer | Must | — |
| verwendungAb 00040 | verwendungAb | string (date-time) | X | — |
| begruendung | — | object | May | — |
| begruendung1 00050 | Reason line 1 | string | X | — |
| begruendung2 00060 | Reason line 2 | string | X | — |
| begruendung3 00070 | Reason line 3 | string | X | — |
| begruendung4 00080 | Reason line 4 | string | X | — |
| begruendung5 00090 | Reason line 5 | string | X | — |
| transaktionsdaten * | — | object | Must | — |
| dokumentennummer * 00100 | EDIFACT reference from the BGM segment / BGM | string | X | — |
| nachrichtendatum * 00110 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenreferenznummer * 00120 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 00130 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| vorgangsnummer * 00140 | Number of the transaction / UTILMD UTILTS IDE+24 / INSRPT INVOIC DOC | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 00150 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00160 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| ansprechpartner * | — | object | Must | — |
| eMailAdresse 00170 | Email address | string | Must | — |
| nachname * 00180 | Surname (family name) of the contact person | string | X | — |
| rufnummern [ ] | — | object[] | May | — |
| nummerntyp 00190 | Phone number type | Enum Rufnummernart | Must | — |
RUF_ZENTRALE | — | — | Must | — |
FAX_ZENTRALE | — | — | Must | — |
SAMMELRUF | — | — | Must | — |
SAMMELFAX | — | — | Must | — |
ABTEILUNGRUF | — | — | Must | — |
ABTEILUNGFAX | — | — | Must | — |
RUF_DURCHWAHL | — | — | Must | — |
FAX_DURCHWAHL | — | — | Must | — |
MOBIL_NUMMER | — | — | Must | — |
| rufnummer 00200 | rufnummer | string | Must | — |
| ansprechpartnerKunde | — | object | May | — |
| eMailAdresse 00210 | Email address | string | Must | — |
| nachname 00220 | Surname (family name) of the contact person | string | X | — |
| rufnummern [ ] | — | object[] | May | — |
| nummerntyp 00230 | Phone number type | Enum Rufnummernart | Must | — |
RUF_ZENTRALE | — | — | Must | — |
FAX_ZENTRALE | — | — | Must | — |
SAMMELRUF | — | — | Must | — |
SAMMELFAX | — | — | Must | — |
ABTEILUNGRUF | — | — | Must | — |
ABTEILUNGFAX | — | — | Must | — |
RUF_DURCHWAHL | — | — | Must | — |
FAX_DURCHWAHL | — | — | Must | — |
MOBIL_NUMMER | — | — | Must | — |
| rufnummer 00240 | rufnummer | string | Must | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 00250 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00260 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 23001 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 INSRPT00020 | Check report | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 10A00040 | Edition 2010 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 1.1a00060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 400070 | Check report | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MR00120 | Message recipient | — | X | — |
303900130 | MP-ID | — | X | — |
3055 900140 | GS1 | — | X | — |
3055 29300150 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
3055 33200160 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00170 | Document-/message sender or sender | — | X | — |
303900180 | MP-ID | — | X | — |
3055 900190 | GS1 | — | X | — |
3055 29300200 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
3055 33200210 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG3.DOC | — | — | Must | — |
1001 2100220 | Request | — | X | — |
100400230 | Transaction number | — | X | — |
| SG4.RFF | — | — | Must | — |
1153 Z1300240 | Check identifier | — | X | — |
1154 2300100250 | WiM / fault report from the LF/NB/MSB to MSB | — | X | — |
| SG5.NAD | — | — | Must | — |
3035 MS00260 | Document-/message sender or sender | — | X | — |
303900270 | MP-ID | — | X | — |
3055 900280 | GS1 | — | X | — |
3055 29300290 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
3055 33200300 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG6.CTA | — | — | Must | — |
3139 IC00310 | Information contact | — | X | — |
341200320 | Contact | — | X | — |
| SG6.COM | — | — | Must | — |
314800330 | Communication address, identification | — | X | — |
3155 EM00340 | — | X | [1P0..1] | |
3155 FX00350 | Fax number | — | X | [1P0..1] |
3155 TE00360 | Telephone | — | X | [1P0..1] |
3155 AJ00370 | further telephone | — | X | [1P0..1] |
3155 AL00380 | Mobile phone | — | X | [1P0..1] |
| SG5.NAD | — | — | Must | — |
3035 CC00390 | Claimant | — | X | — |
| SG6.CTA | — | — | Must | — |
3139 IC00400 | Information contact | — | X | — |
341200410 | Contact | — | X | — |
| SG6.COM | — | — | Must | — |
314800420 | Communication address, identification | — | X | — |
3155 EM00430 | — | X | [1P0..1] | |
3155 FX00440 | Fax number | — | X | [1P0..1] |
3155 TE00450 | Telephone | — | X | [1P0..1] |
3155 AJ00460 | further telephone | — | X | [1P0..1] |
3155 AL00470 | Mobile phone | — | X | [1P0..1] |
| SG7.LIN | — | — | Must | — |
108200480 | Line item number | — | X | [908] [511] |
| SG7.DTM | — | — | May | — |
2005 16300490 | Processing, start date/time | — | X | — |
238000500 | Date or time or time span, value | — | X | ([931] [13] ∧ [495]) ⊻ ([495] ∧ [515]) |
2379 10200510 | CCYYMMDD | — | X | — |
2379 30300520 | CCYYMMDDHHMMZZZ | — | X | — |
| SG7.STS | — | — | Must | — |
9015 Z0600530 | Device status | — | X | — |
4405 Z1100540 | identified fault | — | X | — |
4405 Z1200550 | suspected fault | — | X | — |
| SG7.FTX | — | — | May | — |
4451 ACD00560 | Reason | — | X | — |
444000570 | Free text | — | X | — |
| SG8.NAD | — | — | Must | — |
3035 DP00580 | Supply address | — | X | — |
| SG8.LOC | — | — | Must | — |
3227 17200590 | Reporting point | — | X | — |
322500600 | Identifier | — | X | [951] [509] |
| UNT | — | — | Must | — |
007400610 | Number of segments in a message | — | X | — |
006200620 | Message reference number | — | X | — |
Conditions of this table
The free text of the 10 conditions referenced by the rows above. All conditions of the message type are listed in the condition index INSRPT.
| Marker | Condition |
|---|---|
| [13] | If DE2379 = 303 |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [495] | The point in time must be ≤ the value in DE2380 of DTM+137 |
| [509] | Note: Use of the ID of the metering location |
| [511] | Note: The numbering starts at 1 in every document |
| [515] | Note: "≤ the value in DE2380 of DTM+137" means that the day stated there must be ≥ the day stated in this DTM if code 102 is entered in DE2379. |
| [908] | Format: possible values: 1 to n |
| [931] | Format: ZZZ = +00 |
| [951] | Format: Metering point identifier |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
Example message
UNA:+.? '
UNB+UNOC:3+9907297000002:500+9904446000007:500+{{date}}:{{time}}+LEZCLJ55'
UNH+831848+INSRPT:D:10A:UN:1.1a'
BGM+4+831848BGM'
DTM+137:202302211137?+00:303'
NAD+MR+9904446000007::293'
NAD+MS+9907297000002::293'
DOC+21+12345678910'
RFF+Z13:23001'
NAD+MS+9907297000002::293'
CTA+IC+:Max Mustermann'
COM+max@mustermann.de:EM'
COM+012345678910:AJ'
COM+012345678910:FX'
COM+012345678910:TE'
COM+012345678910:AL'
NAD+CC'
CTA+IC+:Ute Musterfrau'
COM+ute@musterfrau.de:EM'
COM+0123 456789 30:AJ'
COM+0123 456789 10:FX'
COM+0123 456789 20:TE'
COM+0123 456789 40:AL'
LIN+1'
DTM+163:202302151600?+00:303'
STS+Z06+Z12'
FTX+ACD+++Freier Text1'
NAD+DP'
LOC+172+DE0032106765712000000000000000037'
UNT+28+831848'
UNZ+1+LEZCLJ55'[1 item
{6 fields
"data": {3 fields
"stammdaten": {1 field
"STATUSMITTEILUNG": [1 item
{3 fields
"positionsdaten": [1 item
{5 fields
"begruendung": {1 field
"transaktionsdaten": {11 fields
"absender": {6 fields
"ansprechpartner": {5 fields
"rufnummern": [4 items
{2 fields
{2 fields
{2 fields
{2 fields
"empfaenger": {5 fields
"ansprechpartnerKunde": {5 fields
"rufnummern": [4 items
{2 fields
{2 fields
{2 fields
{2 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF, NB, MSB and ÜNB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | Fault rectification in the metering location | AWH WiM gas 2.0 | Gas | Step 1 |
| LF | LF | Fault rectification in the metering location | WiM electricity part 2 | Electricity | Step 1 |
| NB | NB | Fault rectification in the metering location | AWH WiM gas 2.0 | Gas | Step 1 |
| NB | NB | Fault rectification in the metering location | WiM electricity part 2 | Electricity | Step 1 |
| MSB | MSB | Fault rectification in the metering location | AWH WiM gas 2.0 | Gas | Step 1 |
| MSB | MSB-MALO | Fault rectification in the metering location | WiM electricity part 2 | Electricity | Step 1 |
| MSB | MSB-MELO | Fault rectification in the metering location | WiM electricity part 2 | Electricity | Step 1 |
| ÜNB | ÜNB | Fault rectification in the metering location | WiM electricity part 2 | Electricity | Step 1 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Fault report |
| AHB | INSRPT AHB |
| Transmission channel | AS4 |
This check identifier is used in 5 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| WiM electricity part 2 | Fault rectification in the metering location | Fault indicator → MSB (corresponds to MSB on the metering location object) | Notification of a fault |
| AWH WiM gas 2.0 | Fault rectification in the metering location | LF → MSB | Notification of a fault |
| AWH WiM gas 2.0 | Fault rectification in the metering location | NB → MSB | Notification of a fault |
| WiM gas | Ch. C 2.3 No. 1 | LF → MSB | Notification of a fault |
| WiM gas | Ch. C 2.3 No. 1 | NB → MSB | Notification of a fault |
Individual entries from format version 202604
The check identifiers table of format version 202610 does not carry this entry: process step. It comes from version 202604. Version 202604 also carries this check identifier in contexts that the table of version 202610 does not know; they are included in the list above. Everything else on this page — use case, rulebook and communication direction — comes from its own version. Before adopting this into an implementation specification, check whether what is stated applies to 202610.
Transaction and responses
Role of this check identifier: request. Basis: the transaction data carry neither antwortstatus nor antwortstatusCodeliste, and neither the title nor the action of the Prüfi table begins with “response” or “response message”.
Which messages respond to this
| Role | Check identifier | Use case | Message type | Origin of supply |
|---|---|---|---|---|
| Response | 23003 | Rejection | INSRPT | from the step sequence |
| Response | 23004 | Confirmation | INSRPT | from the step sequence |
This column is the inverse of the assignment on the response pages — not the next step of a list. The process source says of its own steps that they are »possible messages, not a sequence«.
Check identifiers of the same AHB table: No other check identifier of message type INSRPT has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 82 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains one transaction for this check identifier under the message type insrpt. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.