Check identifier 23012 — Information notification
Check identifier 23012 · EDIFACT message type INSRPT · Format version 202604
Data structure
| Structure (BO4E) | Description | Format | 23012 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| STATUSMITTEILUNG [ ] * | — | object[] | Must | — |
| positionsdaten [ ] * | — | object[] | Must | — |
| auftragsstatus * 00010 | Order status | Enum Auftragsstatus | X | — |
GESCHEITERT | — | — | X | — |
ERFOLGREICH | — | — | X | — |
LIEFERUNG_GEPLANT | — | — | X | — |
GEPLANT | — | — | X | — |
ZUGESTIMMT | — | — | X | — |
WIDERSPROCHEN | — | — | X | — |
STOERUNGSFREI | — | — | X | — |
GESTOERT | — | — | X | — |
FESTGESTELLTE_STOERUNG | — | — | X | — |
VERMUTETE_STOERUNG | — | — | X | — |
ABGELEHNT | — | — | X | — |
BEENDET | — | — | X | — |
ANTWORT_DRITTER | — | — | X | — |
BESTAETIGT | — | — | X | — |
UMGESETZT | — | — | X | — |
ENFG_STROMSPEICHER_UND_VERLUSTENERGIE | — | — | X | — |
ENFG_ELEKTRISCH_ANGETRIEBENE_WAERMEPUMPEN | — | — | X | — |
ENFG_UMLAGEERHEBUNG_BEI_ANLAGEN_ZUR_VERSTROMUNG_VON_KUPPELGASEN | — | — | X | — |
ENFG_HERSTELLUNG_VON_GRUENEN_WASSERSTOFF | — | — | X | — |
ENFG_STROMKOSTENINTENSIVE_UNTERNEHMEN | — | — | X | — |
ENFG_HERSTELLUNG_VON_WASSERSTOFF_IN_STROMKOSTENINTENSIVEN_UNTERNEHMEN | — | — | X | — |
ENFG_SCHIENENBAHNEN | — | — | X | — |
ENFG_ELEKTRISCHE_BETRIEBENE_BUSSEN_IM_LINIENVERKEHR | — | — | X | — |
ENFG_LANDSTROMANLAGEN | — | — | X | — |
AENDERUNG_DER_DATEN | — | — | X | — |
KEINE_AENDERUNG_DER_DATEN | — | — | X | — |
ZEITREIHE_AKZEPTIERT | — | — | X | — |
ZEITREIHE_NICHT_AKZEPTIERT | — | — | X | — |
| bearbeitungsdatum 00020 | bearbeitungsdatum | string (date-time) | X | — |
| lokationsId * 00030 | lokationsId | string | X | — |
| positionsnummer * 00040 | positionsnummer | integer | Must | — |
| referenzMelo 00050 | referenzMelo | string | X | — |
| statusanlass * 00060 | Status cause | Enum Statusanlass | X | — |
KOMMUNIKATIONSSTOERUNG | — | — | X | — |
STATUS_GERAETEWECHSEL | — | — | X | — |
MESSEINRICHTUNG_GESTOERT_DEFEKT | — | — | X | — |
KEINE_STOERUNG_FESTSTELLBAR | — | — | X | — |
STOERUNGSBEHEBUNG_NICHT_MOEGLICH | — | — | X | — |
REPARATUR_OHNE_GERAETEWECHSEL | — | — | X | — |
| verwendungAb 00070 | verwendungAb | string (date-time) | X | — |
| verwendungBis 00080 | verwendungBis | string (date-time) | X | — |
| fehlerbeschreibung | — | object | May | — |
| beschreibung1 00090 | Error description line 1 | string | X | — |
| beschreibung2 00100 | Error description line 2 | string | X | — |
| beschreibung3 00110 | Error description line 3 | string | X | — |
| beschreibung4 00120 | Error description line 4 | string | X | — |
| beschreibung5 00130 | Error description line 5 | string | X | — |
| transaktionsdaten * | — | object | Must | — |
| anfragereferenznummer * 00140 | Reference transaction number 'from request message' / ORDERS RFF+TN / IFTSTA RFF+AAV / INSRPT RFF+TN RFF+AAV | string | X | — |
| dokumentennummer * 00150 | EDIFACT reference from the BGM segment / BGM | string | X | — |
| nachrichtendatum * 00160 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenreferenznummer * 00170 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 00180 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| vorgangsnummer * 00190 | Number of the transaction / UTILMD UTILTS IDE+24 / INSRPT INVOIC DOC | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 00200 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00210 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 00220 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00230 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 23012 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 INSRPT00020 | Check report | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 10A00040 | Edition 2010 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 1.1a00060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 400070 | Check report | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MR00120 | Message recipient | — | X | — |
303900130 | MP-ID | — | X | [14] |
3055 900140 | GS1 | — | X | — |
3055 29300150 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00160 | Document-/message sender or sender | — | X | — |
303900170 | MP-ID | — | X | [14] |
3055 900180 | GS1 | — | X | — |
3055 29300190 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG3.DOC | — | — | Must | — |
1001 2300200 | Status information | — | X | — |
100400210 | Transaction number | — | X | — |
| SG4.RFF | — | — | Must | — |
1153 Z1300220 | Check identifier | — | X | — |
1154 2301200230 | WiM / information notification (fault rectification) from the MSB of the MaLo | — | X | — |
| SG4.RFF | — | — | Must | — |
1153 TN00240 | Transaction reference number | — | X | — |
115400250 | Document-/transaction number of the reference message | — | X | [508] |
| SG7.LIN | — | — | Must | — |
108200260 | Line item number | — | X | [908] [511] |
| SG7.DTM | — | — | Should | [3] |
2005 900270 | Handling/processing date/time | — | X | — |
238000280 | Date or time or time span, value | — | X | ([931] [13] ∧ [495]) ⊻ ([495] ∧ [515]) |
2379 10200290 | CCYYMMDD | — | X | — |
2379 30300300 | CCYYMMDDHHMMZZZ | — | X | — |
| SG7.DTM | — | — | May | — |
2005 16300310 | Processing, start date/time | — | X | — |
238000320 | Date or time or time span, value | — | X | ([931] [13] ∧ [495]) ⊻ ([495] ∧ [515]) |
2379 10200330 | CCYYMMDD | — | X | — |
2379 30300340 | CCYYMMDDHHMMZZZ | — | X | — |
| SG7.DTM | — | — | Must | — |
2005 16400350 | Processing, end date/time | — | X | — |
238000360 | Date or time or time span, value | — | X | ([931] [13] ∧ [495]) ⊻ ([495] ∧ [515]) |
2379 10200370 | CCYYMMDD | — | X | — |
2379 30300380 | CCYYMMDDHHMMZZZ | — | X | — |
| SG7.STS | — | — | Must | — |
9015 Z0600390 | Device status | — | X | — |
4405 Z0900400 | fault-free | — | X | — |
4405 Z1000410 | faulty | — | X | — |
9013 Z7500420 | Communication fault | — | X | — |
9013 Z7800430 | Device replacement | — | X | — |
9013 Z8100440 | Measuring equipment faulty/defective | — | X | — |
9013 ZB800450 | no fault detectable | — | X | — |
9013 ZC100460 | Fault rectification not possible | — | X | [506] ∧ [507] |
9013 ZS100470 | Repair without device replacement | — | X | — |
| SG7.FTX | — | — | Must | [2] |
4451 AAO00480 | Error description (free text) | — | X | — |
444000490 | Free text | — | X | — |
| SG8.NAD | — | — | Must | — |
3035 DP00500 | Supply address | — | X | — |
| SG8.LOC | — | — | Must | — |
3227 17200510 | Reporting point | — | X | — |
322500520 | Identifier | — | X | [950] [510] |
| SG8.RFF | — | — | Must | [4] ⊻ [5] |
1153 Z2100530 | assigned metering location | — | X | — |
115400540 | ID of a metering location | — | X | [951] [509] |
| UNT | — | — | Must | — |
007400550 | Number of segments in a message | — | X | — |
006200560 | Message reference number | — | X | — |
Conditions of this table
The free text of the 19 conditions referenced by the rows above. All conditions of the message type are listed in the condition index INSRPT.
| Marker | Condition |
|---|---|
| [2] | If SG7 STS+Z06+Z10+ZC1 is present. |
| [3] | If present. |
| [4] | If MP-ID in SG2 NAD+MR in the role NB |
| [5] | If MP-ID in SG2 NAD+MR in the role LF |
| [13] | If DE2379 = 303 |
| [14] | Only MP-ID from the electricity division |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [495] | The point in time must be ≤ the value in DE2380 of DTM+137 |
| [506] | Note: To be used if the fault cannot be rectified by the MSB independently and through no fault of its own. |
| [507] | Note: SG7 FTX+AAO must state the overarching cause due to which the MSB is unable to rectify the fault. |
| [508] | Note: Transaction number from DOC DE1004. |
| [509] | Note: Use of the ID of the metering location |
| [510] | Note: Use of the ID of the market location |
| [511] | Note: The numbering starts at 1 in every document |
| [515] | Note: "≤ the value in DE2380 of DTM+137" means that the day stated there must be ≥ the day stated in this DTM if code 102 is entered in DE2379. |
| [908] | Format: possible values: 1 to n |
| [931] | Format: ZZZ = +00 |
| [950] | Format: market location ID |
| [951] | Format: Metering point identifier |
Example message
Example 1
UNA:+.? '
UNB+UNOC:3+9900599000001:500+9905058000005:500+{{date}}:{{time}}+LETNEGNG'
UNH+UNHLF18893F+INSRPT:D:10A:UN:1.1a'
BGM+4+BGMLF0CRAA0'
DTM+137:202302211047?+00:303'
NAD+MR+9905058000005::293'
NAD+MS+9900599000001::293'
DOC+23+012345678910'
RFF+Z13:23012'
RFF+TN:109876543210'
LIN+1'
DTM+9:202302192300?+00:303'
DTM+163:202302172300?+00:303'
DTM+164:202302192300?+00:303'
STS+Z06+Z10+ZC1'
FTX+AAO+++Freier Text'
NAD+DP'
LOC+172+50188881541'
RFF+Z21:DE0073395252733953513649640711234'
UNT+18+UNHLF18893F'
UNZ+1+LETNEGNG'[1 item
{6 fields
"data": {3 fields
"stammdaten": {1 field
"STATUSMITTEILUNG": [1 item
{3 fields
"positionsdaten": [1 item
{9 fields
"fehlerbeschreibung": {1 field
"transaktionsdaten": {11 fields
"absender": {5 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Example 2
UNA:+.? '
UNB+UNOC:3+9900599000001:500+9905058000005:500+{{date}}:{{time}}+LETNEGNG'
UNH+UNHLF18893F+INSRPT:D:10A:UN:1.1a'
BGM+4+BGMLF0CRAA0'
DTM+137:202302211047?+00:303'
NAD+MR+9905058000005::293'
NAD+MS+9900599000001::293'
DOC+23+012345678910'
RFF+Z13:23012'
RFF+TN:109876543210'
LIN+1'
DTM+164:202302192300?+00:303'
STS+Z06+Z09+ZB8'
NAD+DP'
LOC+172+50188881541'
RFF+Z21:DE0073395252733953513649640711234'
UNT+15+UNHLF18893F'
UNZ+1+LETNEGNG'[1 item
{6 fields
"data": {3 fields
"stammdaten": {1 field
"STATUSMITTEILUNG": [1 item
{3 fields
"positionsdaten": [1 item
{6 fields
"transaktionsdaten": {11 fields
"absender": {5 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF, NB, MSB and ÜNB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | Fault rectification in the metering location | WiM electricity part 2 | Electricity | Step 9 |
| LF | LF | Fault rectification in the metering location | WiM electricity part 2 | Electricity | Step 10 |
| LF | LF | Fault rectification in the metering location | WiM electricity part 2 | Electricity | Step 11 |
| NB | NB | Fault rectification in the metering location | WiM electricity part 2 | Electricity | Step 9 |
| NB | NB | Fault rectification in the metering location | WiM electricity part 2 | Electricity | Step 10 |
| NB | NB | Fault rectification in the metering location | WiM electricity part 2 | Electricity | Step 11 |
| MSB | MSB-MALO | Fault rectification in the metering location | WiM electricity part 2 | Electricity | Step 9 |
| MSB | MSB-MALO | Fault rectification in the metering location | WiM electricity part 2 | Electricity | Step 10 |
| MSB | MSB-MALO | Fault rectification in the metering location | WiM electricity part 2 | Electricity | Step 11 |
| MSB | MSB-MELO | Fault rectification in the metering location | WiM electricity part 2 | Electricity | Step 9 |
| MSB | MSB-MELO | Fault rectification in the metering location | WiM electricity part 2 | Electricity | Step 10 |
| MSB | MSB-MELO | Fault rectification in the metering location | WiM electricity part 2 | Electricity | Step 11 |
| ÜNB | ÜNB | Fault rectification in the metering location | WiM electricity part 2 | Electricity | Step 9 |
| ÜNB | ÜNB | Fault rectification in the metering location | WiM electricity part 2 | Electricity | Step 10 |
| ÜNB | ÜNB | Fault rectification in the metering location | WiM electricity part 2 | Electricity | Step 11 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Information notification |
| AHB | INSRPT AHB |
| Transmission channel | AS4 |
This check identifier is used in 3 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| WiM electricity part 2 | Fault rectification in the metering location | MSB (corresponds to MSB on the object market location) → NB | Information about result of the affected market location |
| WiM electricity part 2 | Fault rectification in the metering location | MSB (corresponds to MSB on the object market location) → LF | Information about result of the affected market location |
| WiM electricity part 2 | Fault rectification in the metering location | MSB (corresponds to MSB on the object market location) → ÜNB | Information about result of the affected market location |
Transaction and responses
Role of this check identifier: request. Basis: the transaction data carry neither antwortstatus nor antwortstatusCodeliste, and neither the title nor the action of the Prüfi table begins with “response” or “response message”. This message does carry anfragereferenznummer, but that is not a role characteristic: in this version the same field is also carried by messages that begin a chain.
Responses: No response of this format version names this check identifier as a reference — neither explicitly in the Prüfi table nor via the step sequence. That does not mean there is none; it means that the sources do not record one.
Check identifiers of the same AHB table: No other check identifier of message type INSRPT has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 74 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains 2 transactions for this check identifier under the message type insrpt. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.