Check identifier 15002 — Quotation billing metering point operation MSB
Check identifier 15002 · EDIFACT message type QUOTES · Format version 202610
This page is derived from the application handbook
The MACO APP does not carry this check identifier. The complete Prüfi pages of this level are produced from the specifications of the application — one class in the templater per check identifier — and that is where the assignment to the business objects (BO4E) comes from: which object carries which field of the message.
The catalogue of the application handbook is the larger set. This page therefore shows what the handbook itself provides — use case, process context and the AHB field list with its conditions. A data structure according to BO4E is not shown, and not because there is none, but because the application does not form one for this check identifier.
All check identifiers in this situation — and the corresponding figures — are listed by the overview of this version.
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 15002 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 QUOTES00020 | Quotation | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 10A00040 | Edition 2010 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 1.3c00060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 Z2900070 | Billing of metering point operation from the MSB to the LF | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| DTM | — | — | Must | [27] |
2005 20300120 | Execution date/time | — | X | — |
238000130 | Date or time or time span, value | — | X | [UB1] |
2379 30300140 | CCYYMMDDHHMMZZZ | — | X | — |
| DTM | — | — | Should | [26] ∧ [28] ∧ [29] |
2005 46900150 | Start date or point in time, earliest | — | X | — |
238000160 | Date or time or time span, value | — | X | [UB1] |
2379 30300170 | CCYYMMDDHHMMZZZ | — | X | — |
| IMD | — | — | Must | — |
7081 Z3300180 | Quotation based on price sheet | — | X | — |
7081 Z3400190 | Individual quotation | — | X | — |
| SG1.RFF | — | — | Must | — |
1153 AAV00200 | Number of the request | — | X | — |
115400210 | Message number | — | X | [505] |
| SG1.RFF | — | — | Must | — |
1153 Z1300220 | Check identifier | — | X | — |
1154 1500200230 | Quotation for invoice processing MSB via LF | — | X | — |
| SG4.CUX | — | — | Must | — |
6347 200240 | Reference currency | — | X | — |
6345 EUR00250 | Euro | — | X | — |
6343 400260 | Currency of the invoice | — | X | — |
| SG11.NAD | — | — | Must | — |
3035 MS00270 | Document-/message sender or sender | — | X | — |
303900280 | MP-ID | — | X | [39] |
3055 900290 | GS1 | — | X | — |
3055 29300300 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG14.CTA | — | — | Must | — |
3139 IC00310 | Information contact | — | X | — |
341200320 | Contact | — | X | — |
| SG14.COM | — | — | Must | — |
314800330 | Communication address, identification | — | X | (([939] [72]) ⊻ ([940] [73])) ∧ [516] |
3155 EM00340 | Electronic mail | — | X | [1P0..1] |
3155 FX00350 | Fax number | — | X | [1P0..1] |
3155 TE00360 | Telephone | — | X | [1P0..1] |
3155 AJ00370 | further telephone | — | X | [1P0..1] |
3155 AL00380 | Mobile phone | — | X | [1P0..1] |
| SG11.NAD | — | — | Must | — |
3035 MR00390 | Message recipient | — | X | — |
303900400 | MP-ID | — | X | [39] |
3055 900410 | GS1 | — | X | — |
3055 29300420 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG11.NAD | — | — | Must | — |
3035 DP00430 | Supply address | — | X | — |
| SG11.LOC | — | — | Must | — |
3227 17200440 | Reporting point | — | X | — |
322500450 | Identifier | — | X | [950] [501] |
| SG27.LIN | — | — | Must | — |
108200460 | Line item number | — | X | [911] |
714000470 | Product/service number | — | X | ([31] ∧ ([65] ⊻ [66])) ⊻ ([942] [69] ∧ ([67] ⊻ [68])) |
7143 Z0100480 | Article number | — | X | [65] ⊻ [66] |
7143 Z0900490 | Article ID | — | X | [67] ⊻ [68] |
| SG27.PIA | — | — | Must | [20] ∧ ([65] ⊻ [66]) |
4347 100500 | Additional identification | — | X | — |
714000510 | Price key master data | — | X | — |
7143 Z0600520 | Price key master data | — | X | — |
| SG31.PRI | — | — | Must | — |
5125 CAL00530 | Calculation price | — | X | — |
511800540 | Price, amount | — | — | M [21] ∧ [912] |
528400550 | Unit price basis, quantity | — | X | [908] |
6411 H8700560 | Piece | — | X | — |
6411 DAY00570 | Day | — | X | [21] |
| SG32.RFF | — | — | Must | — |
1153 Z1800580 | Market location | — | X | — |
115400590 | ID of a market location | — | X | [950] |
| UNS | — | — | Must | — |
0081 S00600 | Separation of detail and summary section | — | X | — |
| UNT | — | — | Must | — |
007400610 | Number of segments in a message | — | X | — |
006200620 | Message reference number | — | X | — |
Conditions of this table
The free text of the 29 conditions referenced by the rows above. All conditions of the message type are listed in the condition index QUOTES.
| Marker | Condition |
|---|---|
| [20] | If IMD++Z33 present |
| [21] | If IMD++Z34 present |
| [26] | If DTM+203 not present |
| [27] | If DTM+469 not present |
| [28] | If RFF+AAV present |
| [29] | If DTM+469 was present in the request (REQOTE) |
| [31] | Only the article numbers are permitted that are marked with the corresponding check identifier in the code list of article numbers of the BDEW. |
| [39] | MP-ID only from division electricity |
| [65] | If DTM+203 (execution date) in DE2380 < 202312312300?+00 |
| [66] | If DTM+469 (start at the (earliest possible date)) in DE2380 < 202312312300?+00 |
| [67] | If DTM+203 (execution date) in DE2380 ≥ 202312312300?+00 |
| [68] | If DTM+469 (start at the (earliest possible date)) in DE2380 ≥ 202312312300?+00 |
| [69] | Only values from the EDI@Energy code list of article numbers and article IDs that are stated in chapter 3.5 "Billing of metering point operation for the electricity division" are permitted. |
| [72] | if the code EM is present in DE3155 in the same COM |
| [73] | if the code TE / FX / AJ / AL is present in DE3155 in the same COM |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that. |
| [501] | Note: Use of the ID of the market location |
| [505] | Note: Value from BGM+Z29 DE1004 of the REQOTE with which the request for invoice processing was made. |
| [516] | Note: Only one piece of information may be transmitted in DE3148 |
| [908] | Format: possible values: 1 to n |
| [911] | Format: Possible values: 1 to n, starting at 1 for each message or segment group and ascending consecutively |
| [912] | Format: max. 6 decimal places |
| [931] | Format: ZZZ = +00 |
| [939] | Format: the character string must contain the characters @ and . |
| [940] | Format: the character string must begin with the character + and may only be followed by digits |
| [942] | Format: n1-n2-n1-n3 |
| [950] | Format: market location ID |
| [UB1] | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF and MSB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | Request for invoice processing of the metering point operation via the LF by the LF | WiM electricity part 1 | Electricity | Step 2 |
| LF | LF | Quotation for invoice processing of the metering point operation via the LF by the MSB | WiM electricity part 1 | Electricity | Step 1 |
| MSB | MSB-MALO | Request for invoice processing of the metering point operation via the LF by the LF | WiM electricity part 1 | Electricity | Step 2 |
| MSB | MSB-MALO | Quotation for invoice processing of the metering point operation via the LF by the MSB | WiM electricity part 1 | Electricity | Step 1 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Quotation for billing of metering point operation MSB |
| AHB | QUOTES AHB |
| Transmission channel | AS4 |
This check identifier is used in 2 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| WiM electricity part 1 | Quotation for invoice processing of metering point operation via the LF by the MSB | MSB (corresponds to MSB on the object market location) → LF | Quotation for invoice processing of metering point operation via the LF |
| WiM electricity part 1 | Request for invoice processing of metering point operation via the LF by the LF | MSB (corresponds to MSB on the object market location) → LF | Quotation /rejection of request |
Notes on this page
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 83 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.