Check identifier 15001 — Quotation device takeover
Check identifier 15001 · EDIFACT message type QUOTES · Format version 202604
Data structure
| Structure (BO4E) | Description | Format | 15001 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| ANFRAGE [ ] * | — | object[] | Must | — |
| anfragetyp * 00010 | Type/kind of the request (ORDERS ORDRSP IMD 7081) | Enum Anfragetyp | Must | — |
KAUF | — | — | Must | — |
NUTZUNGSUEBERLASSUNG | — | — | Must | — |
ABRECHNUNGSBRENNWERT_UND_ZUSTANDSZAHL | — | — | Must | — |
LASTGANGDATEN | — | — | Must | — |
ZAEHLERSTAENDE | — | — | Must | — |
WERTEERMITTLUNG | — | — | Must | — |
ENERGIEMENGE_EINZELWERT | — | — | Must | — |
INNERHALB_DER_ARBEITSZEIT | — | — | Must | — |
AUCH_AUSSERHALB_DER_ARBEITSZEIT | — | — | Must | — |
WECHSEL_SAEMTLICHER_EINRICHTUNGEN | — | — | Must | — |
TEILWEISER_WECHSEL | — | — | Must | — |
AENDERUNG_ZAEHLZEITDEFINITION | — | — | Must | — |
ABBESTELLUNG_ZAEHLZEITEN | — | — | Must | — |
ABBESTELLUNG_MESSPRODUKT | — | — | Must | — |
ANGEBOT_AUF_BASIS_PREISBLATT | — | — | Must | — |
INDIVIDUELLES_ANGEBOT | — | — | Must | — |
AENDERUNG_KONFIGURATION | — | — | Must | — |
KANN_NICHT_ANGEBOTEN_WERDEN | — | — | Must | — |
NEUKONFIGURATION | — | — | Must | — |
BEENDIGUNG_KONFIGURATION | — | — | Must | — |
AKTIVIERUNG_KONFIGURATION | — | — | Must | — |
| ANGEBOT [ ] * | — | object[] | Must | — |
| anfragereferenz * 00020 | Reference to a request or tender. Can help the recipient of the quotation to assign the quotation to the request or tender. | string | X | — |
| angebotsdatum * 00030 | Creation date of the quotation | string (date-time) | X | — |
| positionsdaten [ ] * | — | object[] | Must | — |
| anbietbar 00040 | — | boolean | Should | [1] |
| artikelnummer * 00050 | BDEW article number | Enum BDEWArtikelnummer | Must | — |
LEISTUNG | — | — | Must | — |
LEISTUNG_PAUSCHAL | — | — | Must | — |
GRUNDPREIS | — | — | Must | — |
REGELENERGIE_ARBEIT | — | — | Must | — |
REGELENERGIE_LEISTUNG | — | — | Must | — |
NOTSTROMLIEFERUNG_ARBEIT | — | — | Must | — |
NOTSTROMLIEFERUNG_LEISTUNG | — | — | Must | — |
RESERVENETZKAPAZITAET | — | — | Must | — |
RESERVELEISTUNG | — | — | Must | — |
ZUSAETZLICHE_ABLESUNG | — | — | Must | — |
PRUEFGEBUEHREN_AUSSERPLANMAESSIG | — | — | Must | — |
WIRKARBEIT | — | — | Must | — |
SINGULAER_GENUTZTE_BETRIEBSMITTEL | — | — | Must | — |
ABGABE_KWKG | — | — | Must | — |
ABSCHLAG | — | — | Must | — |
KONZESSIONSABGABE | — | — | Must | — |
ENTGELT_FERNAUSLESUNG | — | — | Must | — |
UNTERMESSUNG | — | — | Must | — |
BLINDMEHRARBEIT | — | — | Must | — |
ENTGELT_ABRECHNUNG | — | — | Must | — |
SPERRKOSTEN | — | — | Must | — |
ENTSPERRKOSTEN | — | — | Must | — |
MAHNKOSTEN | — | — | Must | — |
MEHR_MINDERMENGEN | — | — | Must | — |
INKASSOKOSTEN | — | — | Must | — |
BLINDMEHRLEISTUNG | — | — | Must | — |
ENTGELT_MESSUNG_ABLESUNG | — | — | Must | — |
ENTGELT_EINBAU_BETRIEB_WARTUNG_MESSTECHNIK | — | — | Must | — |
AUSGLEICHSENERGIE | — | — | Must | — |
AUSGLEICHSENERGIE_UNTERDECKUNG | — | — | Must | — |
ZAEHLEINRICHTUNG | — | — | Must | — |
WANDLER_MENGENUMWERTER | — | — | Must | — |
KOMMUNIKATIONSEINRICHTUNG | — | — | Must | — |
TECHNISCHE_STEUEREINRICHTUNG | — | — | Must | — |
PARAGRAF_19_STROM_NEV_UMLAGE | — | — | Must | — |
BEFESTIGUNGSEINRICHTUNG | — | — | Must | — |
OFFSHORE_HAFTUNGSUMLAGE | — | — | Must | — |
FIXE_ARBEITSENTGELTKOMPONENTE | — | — | Must | — |
FIXE_LEISTUNGSENTGELTKOMPONENTE | — | — | Must | — |
UMLAGE_ABSCHALTBARE_LASTEN | — | — | Must | — |
MEHRMENGE | — | — | Must | — |
MINDERMENGE | — | — | Must | — |
ENERGIESTEUER | — | — | Must | — |
SMARTMETER_GATEWAY | — | — | Must | — |
STEUERBOX | — | — | Must | — |
MSB_INKL_MESSUNG | — | — | Must | — |
ZUSATZDIENSTLEISTUNG_PARAGRAPH_35_2_1_MSBG | — | — | Must | — |
ZUSATZDIENSTLEISTUNG_PARAGRAPH_35_2_2_MSBG | — | — | Must | — |
ZUSATZDIENSTLEISTUNG_PARAGRAPH_35_2_3_MSBG | — | — | Must | — |
ZUSATZDIENSTLEISTUNG_PARAGRAPH_35_2_4_MSBG | — | — | Must | — |
ZUSATZDIENSTLEISTUNG_PARAGRAPH_35_2_5_MSBG | — | — | Must | — |
ZUSATZDIENSTLEISTUNG_PARAGRAPH_35_3_MSBG | — | — | Must | — |
ENTGELT_KAPAZITAETEN | — | — | Must | — |
| freitext 00060 | Additional information (for general notes) | string | X | — |
| positionsbezeichnung * 00070 | Designation of the line item | string | Must | — |
| beteiligterMarktpartner | — | object | May | — |
| rollencodenummer 00080 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp 00090 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| positionspreis [ ] | — | object[] | May | — |
| bezugswert 00100 | Unit: measurands that can be determined by measurement or by specification | Enum Mengeneinheit | X | — |
W | — | — | X | — |
WH | — | — | X | — |
KW | — | — | X | — |
KWH | — | — | X | — |
KVARH | — | — | X | — |
MW | — | — | X | — |
MWH | — | — | X | — |
STUECK | — | — | X | — |
KUBIKMETER | — | — | X | — |
STUNDE | — | — | X | — |
TAG | — | — | X | — |
MONAT | — | — | X | — |
JAHR | — | — | X | — |
PROZENT | — | — | X | — |
ANZAHL | — | — | X | — |
VAR | — | — | X | — |
KVAR | — | — | X | — |
VARH | — | — | X | — |
KWHK | — | — | X | — |
Z16 | — | — | X | — |
KWT | — | — | X | — |
WATT_PRO_QUADRATMETER | — | — | X | — |
METER_PRO_SEKUNDE | — | — | X | — |
| menge 00110 | menge | integer | X | — |
| wert 00120 | wert | number (float) | X | — |
| verweisKatalognummer | — | object | May | — |
| katalognummer 00130 | Catalog number | string | X | — |
| versionsnummer 00140 | Version number | string | X | — |
| zeilennummer 00150 | Line number | string | X | — |
| MESSLOKATION [ ] * | — | object[] | Must | — |
| messlokationsId * 00160 | The metering location identification. This is the former metering point identifier, e.g. DE 47108151234567 | string | X | — |
| ZAEHLER [ ] | — | object[] | May | — |
| befestigungsart 00170 | Mounting type | Enum Befestigungsart | Must | — |
STECKTECHNIK | — | — | Must | — |
DREIPUNKT | — | — | Must | — |
HUTSCHIENE | — | — | Must | — |
EINSTUTZEN | — | — | Must | — |
ZWEISTUTZEN | — | — | Must | — |
| eichungBis 00180 | The meter is calibrated up to this date. | string | X | — |
| messwerterfassung 00190 | Meter reading capture at the metering point | Enum Messwerterfassung | Must | — |
FERNAUSLESBAR | — | — | Must | — |
MANUELL_AUSGELESENE | — | — | Must | — |
| tarifart 00200 | Specification regarding supported tariff types. | Enum Tarifart | Must | — |
EINTARIF | — | — | Must | — |
ZWEITARIF | — | — | Must | — |
MEHRTARIF | — | — | Must | — |
SMART_METER | — | — | Must | — |
LEISTUNGSGEMESSEN | — | — | Must | — |
| zaehlerauspraegung 00210 | Specification regarding the direction of the meter. | Enum Zaehlerauspraegung | Must | — |
EINRICHTUNGSZAEHLER | — | — | Must | — |
ZWEIRICHTUNGSZAEHLER | — | — | Must | — |
| zaehlergroesse 00220 | Meter size | Enum Geraetemerkmal | Must | — |
EINTARIF | — | — | Must | — |
ZWEITARIF | — | — | Must | — |
MEHRTARIF | — | — | Must | — |
GAS_G2P5 | — | — | Must | — |
GAS_G4 | — | — | Must | — |
GAS_G6 | — | — | Must | — |
GAS_G10 | — | — | Must | — |
GAS_G16 | — | — | Must | — |
GAS_G25 | — | — | Must | — |
GAS_G40 | — | — | Must | — |
GAS_G65 | — | — | Must | — |
GAS_G100 | — | — | Must | — |
GAS_G160 | — | — | Must | — |
GAS_G250 | — | — | Must | — |
GAS_G350 | — | — | Must | — |
GAS_G400 | — | — | Must | — |
GAS_G4000 | — | — | Must | — |
GAS_G650 | — | — | Must | — |
GAS_G6500 | — | — | Must | — |
GAS_G1000 | — | — | Must | — |
GAS_G10000 | — | — | Must | — |
GAS_G12500 | — | — | Must | — |
GAS_G1600 | — | — | Must | — |
GAS_G16000 | — | — | Must | — |
GAS_G2500 | — | — | Must | — |
IMPULSGEBER_G4_G100 | — | — | Must | — |
IMPULSGEBER_G100 | — | — | Must | — |
MODEM_GSM | — | — | Must | — |
MODEM_GPRS | — | — | Must | — |
MODEM_FUNK | — | — | Must | — |
MODEM_GSM_O_LG | — | — | Must | — |
MODEM_GSM_M_LG | — | — | Must | — |
MODEM_FESTNETZ | — | — | Must | — |
MODEM_GPRS_M_LG | — | — | Must | — |
PLC_COM | — | — | Must | — |
ETHERNET_KOM | — | — | Must | — |
DSL_KOM | — | — | Must | — |
LTE_KOM | — | — | Must | — |
RUNDSTEUEREMPFAENGER | — | — | Must | — |
TARIFSCHALTGERAET | — | — | Must | — |
ZUSTANDS_MU | — | — | Must | — |
TEMPERATUR_MU | — | — | Must | — |
KOMPAKT_MU | — | — | Must | — |
SYSTEM_MU | — | — | Must | — |
UNBESTIMMT | — | — | Must | — |
WASSER_MWZW | — | — | Must | — |
WASSER_WZWW | — | — | Must | — |
WASSER_WZ01 | — | — | Must | — |
WASSER_WZ02 | — | — | Must | — |
WASSER_WZ03 | — | — | Must | — |
WASSER_WZ04 | — | — | Must | — |
WASSER_WZ05 | — | — | Must | — |
WASSER_WZ06 | — | — | Must | — |
WASSER_WZ07 | — | — | Must | — |
WASSER_WZ08 | — | — | Must | — |
WASSER_WZ09 | — | — | Must | — |
WASSER_WZ10 | — | — | Must | — |
WASSER_VWZ04 | — | — | Must | — |
WASSER_VWZ05 | — | — | Must | — |
WASSER_VWZ06 | — | — | Must | — |
WASSER_VWZ07 | — | — | Must | — |
WASSER_VWZ10 | — | — | Must | — |
DICHTEMENGENUMWERTER | — | — | Must | — |
TEMPERATURMENGENUMWERTER | — | — | Must | — |
ZUSTANDSMENGENUMWERTER | — | — | Must | — |
BLOCKSTROMWANDLER | — | — | Must | — |
MESSWANDLERSATZ_IMS_MME | — | — | Must | — |
KOMBIMESSWANDLER | — | — | Must | — |
SPANNUNGSWANDLER | — | — | Must | — |
| zaehlertyp 00230 | Typing of the meter | Enum Zaehlertyp | Must | — |
DREHSTROMZAEHLER | — | — | Must | — |
BALGENGASZAEHLER | — | — | Must | — |
DREHKOLBENZAEHLER | — | — | Must | — |
SMARTMETER | — | — | Must | — |
LEISTUNGSZAEHLER | — | — | Must | — |
MAXIMUMZAEHLER | — | — | Must | — |
TURBINENRADGASZAEHLER | — | — | Must | — |
ULTRASCHALLGASZAEHLER | — | — | Must | — |
WECHSELSTROMZAEHLER | — | — | Must | — |
WIRBELGASZAEHLER | — | — | Must | — |
MESSDATENREGISTRIERGERAET | — | — | Must | — |
ELEKTRONISCHERHAUSHALTSZAEHLER | — | — | Must | — |
SONDERAUSSTATTUNG | — | — | Must | — |
WASSERZAEHLER | — | — | Must | — |
MODERNEMESSEINRICHTUNG | — | — | Must | — |
| zaehlertypspezifikation 00240 | Typing of the meter (specification for EHZ and MME) | Enum ZaehlertypSpezifikation | Must | — |
EDL40 | — | — | Must | — |
EDL21 | — | — | Must | — |
SONSTIGER_EHZ | — | — | Must | — |
MME_STANDARD | — | — | Must | — |
MME_MEDA | — | — | Must | — |
| geraete [ ] | — | object[] | May | — |
| geraeteeigenschaften | — | object | May | — |
| faktor 00250 | faktor | number (float) | Must | — |
| geraetemerkmal 00260 | Geraetemerkmal | Enum Geraetemerkmal | Must | — |
EINTARIF | — | — | Must | — |
ZWEITARIF | — | — | Must | — |
MEHRTARIF | — | — | Must | — |
GAS_G2P5 | — | — | Must | — |
GAS_G4 | — | — | Must | — |
GAS_G6 | — | — | Must | — |
GAS_G10 | — | — | Must | — |
GAS_G16 | — | — | Must | — |
GAS_G25 | — | — | Must | — |
GAS_G40 | — | — | Must | — |
GAS_G65 | — | — | Must | — |
GAS_G100 | — | — | Must | — |
GAS_G160 | — | — | Must | — |
GAS_G250 | — | — | Must | — |
GAS_G350 | — | — | Must | — |
GAS_G400 | — | — | Must | — |
GAS_G4000 | — | — | Must | — |
GAS_G650 | — | — | Must | — |
GAS_G6500 | — | — | Must | — |
GAS_G1000 | — | — | Must | — |
GAS_G10000 | — | — | Must | — |
GAS_G12500 | — | — | Must | — |
GAS_G1600 | — | — | Must | — |
GAS_G16000 | — | — | Must | — |
GAS_G2500 | — | — | Must | — |
IMPULSGEBER_G4_G100 | — | — | Must | — |
IMPULSGEBER_G100 | — | — | Must | — |
MODEM_GSM | — | — | Must | — |
MODEM_GPRS | — | — | Must | — |
MODEM_FUNK | — | — | Must | — |
MODEM_GSM_O_LG | — | — | Must | — |
MODEM_GSM_M_LG | — | — | Must | — |
MODEM_FESTNETZ | — | — | Must | — |
MODEM_GPRS_M_LG | — | — | Must | — |
PLC_COM | — | — | Must | — |
ETHERNET_KOM | — | — | Must | — |
DSL_KOM | — | — | Must | — |
LTE_KOM | — | — | Must | — |
RUNDSTEUEREMPFAENGER | — | — | Must | — |
TARIFSCHALTGERAET | — | — | Must | — |
ZUSTANDS_MU | — | — | Must | — |
TEMPERATUR_MU | — | — | Must | — |
KOMPAKT_MU | — | — | Must | — |
SYSTEM_MU | — | — | Must | — |
UNBESTIMMT | — | — | Must | — |
WASSER_MWZW | — | — | Must | — |
WASSER_WZWW | — | — | Must | — |
WASSER_WZ01 | — | — | Must | — |
WASSER_WZ02 | — | — | Must | — |
WASSER_WZ03 | — | — | Must | — |
WASSER_WZ04 | — | — | Must | — |
WASSER_WZ05 | — | — | Must | — |
WASSER_WZ06 | — | — | Must | — |
WASSER_WZ07 | — | — | Must | — |
WASSER_WZ08 | — | — | Must | — |
WASSER_WZ09 | — | — | Must | — |
WASSER_WZ10 | — | — | Must | — |
WASSER_VWZ04 | — | — | Must | — |
WASSER_VWZ05 | — | — | Must | — |
WASSER_VWZ06 | — | — | Must | — |
WASSER_VWZ07 | — | — | Must | — |
WASSER_VWZ10 | — | — | Must | — |
DICHTEMENGENUMWERTER | — | — | Must | — |
TEMPERATURMENGENUMWERTER | — | — | Must | — |
ZUSTANDSMENGENUMWERTER | — | — | Must | — |
BLOCKSTROMWANDLER | — | — | Must | — |
MESSWANDLERSATZ_IMS_MME | — | — | Must | — |
KOMBIMESSWANDLER | — | — | Must | — |
SPANNUNGSWANDLER | — | — | Must | — |
| transaktionsdaten * | — | object | Must | — |
| dokumentennummer * 00270 | EDIFACT reference from the BGM segment / BGM | string | X | — |
| kategorie * 00280 | Qualifier from the beginning of the EDIFACT message / BGM | string | X | — |
| nachrichtendatum * 00290 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenreferenznummer * 00300 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 00310 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 00320 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00330 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| ansprechpartner * | — | object | Must | — |
| eMailAdresse 00340 | Email address | string | Must | — |
| nachname * 00350 | Surname (family name) of the contact person | string | Must | — |
| rufnummern [ ] | — | object[] | May | — |
| nummerntyp 00360 | Phone number type | Enum Rufnummernart | Must | — |
RUF_ZENTRALE | — | — | Must | — |
FAX_ZENTRALE | — | — | Must | — |
SAMMELRUF | — | — | Must | — |
SAMMELFAX | — | — | Must | — |
ABTEILUNGRUF | — | — | Must | — |
ABTEILUNGFAX | — | — | Must | — |
RUF_DURCHWAHL | — | — | Must | — |
FAX_DURCHWAHL | — | — | Must | — |
MOBIL_NUMMER | — | — | Must | — |
| rufnummer 00370 | rufnummer | string | Must | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 00380 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00390 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 15001 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 QUOTES00020 | Quotation | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 10A00040 | Edition 2010 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 1.3b00060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 31000070 | Quotation | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/ message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| DTM | — | — | Must | — |
2005 7600120 | Delivery date/time, scheduled | — | X | — |
238000130 | Date or time or time span, value | — | X | [UB3] |
2379 30300140 | CCYYMMDDHHMMZZZ | — | X | — |
| IMD | — | — | Must | — |
7081 Z0700150 | Purchase | — | X | — |
7081 Z0800160 | Transfer of use | — | X | — |
| SG1.RFF | — | — | Must | — |
1153 AAV00170 | Number of the request | — | X | — |
115400180 | Message number | — | X | [504] |
| SG1.RFF | — | — | Must | — |
1153 Z1300190 | Check identifier | — | X | — |
1154 1500100200 | Quotation for device takeover | — | X | — |
| SG4.CUX | — | — | Must | — |
6347 200210 | Reference currency | — | X | — |
6345 EUR00220 | Euro | — | X | — |
6343 400230 | Currency of the invoice | — | X | — |
| SG11.NAD | — | — | Must | — |
3035 MS00240 | Document-/ message sender or sender | — | X | — |
303900250 | MP-ID | — | X | — |
3055 900260 | GS1 | — | X | — |
3055 29300270 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
3055 33200280 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG14.CTA | — | — | Must | — |
3139 IC00290 | Information contact | — | X | — |
341200300 | Contact | — | X | [500] |
| SG14.COM | — | — | Must | — |
314800310 | Communication address, identification | — | X | (([939] [72]) ∨ ([940] [73])) ∧ [516] |
3155 EM00320 | Electronic mail | — | X | [1P0..1] |
3155 FX00330 | Fax number | — | X | [1P0..1] |
3155 TE00340 | Telephone | — | X | [1P0..1] |
3155 AJ00350 | further telephone | — | X | [1P0..1] |
3155 AL00360 | Mobile phone | — | X | [1P0..1] |
| SG11.NAD | — | — | Must | — |
3035 MR00370 | Message recipient | — | X | — |
303900380 | MP-ID | — | X | — |
3055 900390 | GS1 | — | X | — |
3055 29300400 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
3055 33200410 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG11.NAD | — | — | Must | — |
3035 DP00420 | Supply address | — | X | — |
| SG11.LOC | — | — | Must | — |
3227 17200430 | Reporting point | — | X | — |
322500440 | Identifier | — | X | [951] [502] |
| SG27.LIN | — | — | Must | — |
108200450 | Line item number | — | X | [911] |
714000460 | Product/service number | — | X | [31] |
7143 Z0100470 | Article number | — | X | — |
| SG27.IMD | — | — | Should | [1] |
7081 Z0900480 | Cannot be offered | — | X | — |
| SG27.DTM | — | — | Must | [2] |
2005 9400490 | Production/manufacturing date | — | X | — |
2005 Z0300500 | Year of manufacture / year of placing on the market | — | X | — |
238000510 | Date or time or time span, value | — | X | — |
2379 60200520 | CCYY | — | X | — |
| SG27.DTM | — | — | Must | [2] ∧ ([5] ⊻ [3] ⊻ [22]) |
2005 Z0400530 | Calibration validity | — | X | — |
238000540 | Date or time or time span, value | — | X | — |
2379 60200550 | CCYY | — | X | — |
| SG27.GIN | — | — | Should | [2] ∧ [4] |
7405 BN00560 | Serial number | — | X | — |
740200570 | Manufacturer number | — | X | — |
| SG27.FTX | — | — | May | — |
4451 ACB00580 | Additional information (for general notes) | — | X | — |
444000590 | Free text | — | X | — |
| SG28.CCI | — | — | Must | — |
7037 E1300600 | Meter type | — | X | — |
| SG28.CAV | — | — | Must | — |
7111 AHZ00610 | analog household meter (three-phase current) | — | X | [492] |
7111 BGZ00620 | Diaphragm gas meter | — | X | [493] |
7111 DKZ00630 | Rotary piston gas meter | — | X | [493] |
7111 EHZ00640 | electronic household meter | — | X | — |
7111 IVA00650 | Individual reconciliation (special equipment) | — | X | — |
7111 LAZ00660 | Load curve meter | — | X | [492] |
7111 MAZ00670 | Maximum demand meter | — | X | [492] |
7111 MME00680 | modern metering device according to MsbG | — | X | — |
7111 MRG00690 | Measurement data recording device | — | X | [493] |
7111 TRZ00700 | Turbine gas meter | — | X | [493] |
7111 UGZ00710 | Ultrasonic gas meter | — | X | [493] |
7111 WGZ00720 | Vortex gas meter | — | X | [493] |
7111 WSZ00730 | analog alternating current meter | — | X | [492] |
7110 Z0100740 | EDL40 | — | X | [8] |
7110 Z0200750 | EDL21 | — | X | [8] |
7110 Z0300760 | other EHZ | — | X | [8] |
7110 Z0400770 | Standard | — | X | [25] |
7110 Z0500780 | MeDa meter | — | X | [25] |
| SG28.CAV | — | — | Must | [493] |
7110 G1000790 | Gas meter G10 | — | X | — |
7110 G10000800 | Gas meter G100 | — | X | — |
7110 G100000810 | Gas meter G1000 | — | X | — |
7110 G1000000820 | Gas meter G10000 | — | X | — |
7110 G1250000830 | Gas meter G12500 | — | X | — |
7110 G1600840 | Gas meter G16 | — | X | — |
7110 G16000850 | Gas meter G160 | — | X | — |
7110 G160000860 | Gas meter G1600 | — | X | — |
7110 G1600000870 | Gas meter G16000 | — | X | — |
7110 G2.500880 | Gas meter G2.5 | — | X | — |
7110 G2500890 | Gas meter G25 | — | X | — |
7110 G25000900 | Gas meter G250 | — | X | — |
7110 G250000910 | Gas meter G2500 | — | X | — |
7110 G35000920 | Gas meter G350 | — | X | — |
7110 G400930 | Gas meter G4 | — | X | — |
7110 G4000940 | Gas meter G40 | — | X | — |
7110 G40000950 | Gas meter G400 | — | X | — |
7110 G400000960 | Gas meter G4000 | — | X | — |
7110 G600970 | Gas meter G6 | — | X | — |
7110 G6500980 | Gas meter G65 | — | X | — |
7110 G65000990 | Gas meter G650 | — | X | — |
7110 G650001000 | Gas meter G6500 | — | X | — |
| SG28.CAV | — | — | Must | [492] |
7111 ETZ01010 | Single tariff | — | X | — |
7111 ZTZ01020 | Two-tariff | — | X | — |
7111 NTZ01030 | Multi-tariff | — | X | — |
| SG28.CAV | — | — | Must | [492] |
7111 ERZ01040 | Single-direction meter | — | X | — |
7111 ZRZ01050 | Bidirectional meter | — | X | — |
| SG28.CCI | — | — | Must | — |
7037 Z2501060 | Instrument transformer | — | X | — |
| SG28.CAV | — | — | Must | — |
7111 MBW01070 | Block current transformer | — | X | — |
7111 MIW01080 | Current transformer set | — | X | — |
7111 MPW01090 | Combined instrument transformer set (current and voltage) | — | X | — |
7111 MUW01100 | Voltage transformer set | — | X | — |
711001110 | Instrument transformer factor | — | — | M [914] [10] |
| SG28.CCI | — | — | Must | — |
7037 Z6401120 | Volume corrector | — | X | — |
| SG28.CAV | — | — | Must | — |
7111 DMU01130 | Density volume converter | — | X | — |
7111 TMU01140 | Temperature volume converter | — | X | — |
7111 ZMU01150 | Volume conversion device | — | X | — |
| SG28.CCI | — | — | Must | — |
7037 Z2601160 | Communication device | — | X | — |
| SG28.CAV | — | — | Must | — |
7111 GSM01170 | GSM/GPRS/UMTS comm. dev. | — | X | — |
7111 ETH01180 | Ethernet comm. dev. LAN/WLAN | — | X | — |
7111 PLC01190 | PLC comm. device | — | X | — |
7111 PST01200 | Landline comm. dev. TAE | — | X | — |
7111 DSL01210 | DSL comm. dev. | — | X | — |
7111 LTE01220 | LTE comm. dev. | — | X | — |
| SG28.CCI | — | — | Must | — |
7037 Z2701230 | Technical control device | — | X | — |
| SG28.CAV | — | — | Must | — |
7111 RSU01240 | Ripple control receiver | — | X | — |
7111 TSU01250 | Tariff time switch | — | X | — |
| SG28.CCI | — | — | Must | — |
7037 Z7501260 | Smart meter gateway | — | X | — |
| SG28.CCI | — | — | Must | — |
7037 Z7601270 | Control box | — | X | — |
| SG28.CCI | — | — | Must | — |
7037 Z2801280 | Mounting type metering device | — | X | — |
| SG28.CAV | — | — | Must | — |
7111 BKE01290 | Plug-in technology (mounting and contacting device) | — | X | [492] |
7111 DPA01300 | 3-Three-point suspension | — | X | [492] |
7111 HUT01310 | DIN rail | — | X | [492] |
7111 Z3101320 | Single-connection meter | — | X | [493] |
7111 Z3201330 | Two-connection meter | — | X | [493] |
| SG28.CCI | — | — | Must | — |
7037 E1201340 | Meter reading capture at the metering device | — | X | — |
| SG28.CAV | — | — | Must | — |
7111 AMR01350 | remotely readable meters | — | X | — |
7111 MMR01360 | manually read meters | — | X | — |
| SG31.PRI | — | — | Must | — |
5125 CAL01370 | Calculation price | — | X | — |
511801380 | Price, amount | — | X | [912] |
528401390 | Unit price basis, quantity | — | X | [908] |
6411 H8701400 | Piece | — | X | [79] |
6411 DAY01410 | Day | — | X | [80] |
| SG32.RFF | — | — | Must | — |
1153 Z0901420 | Device number | — | X | — |
115401430 | Device number | — | X | — |
| SG32.RFF | — | — | Must | — |
1153 APF01440 | Reference to catalogue number | — | X | — |
115401450 | Catalog number | — | X | — |
115601460 | Line number | — | X | — |
105601470 | Version number | — | X | — |
| SG42.NAD | — | — | Must | — |
3035 VY01480 | other associated party | — | X | — |
303901490 | MP-ID | — | X | — |
3055 901500 | GS1 | — | X | — |
3055 29301510 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
3055 33201520 | DE, DVGW Service & Consult GmbH | — | X | — |
| UNS | — | — | Must | — |
0081 S01530 | Separation of detail and summary section | — | X | — |
| UNT | — | — | Must | — |
007401540 | Number of segments in a message | — | X | — |
006201550 | Message reference number | — | X | — |
Conditions of this table
The free text of the 31 conditions referenced by the rows above. All conditions of the message type are listed in the condition index QUOTES.
| Marker | Condition |
|---|---|
| [1] | If the item cannot be offered because legal provisions or third-party rights preclude this |
| [2] | If in the same SG27 LIN IMD DE7081 (product/ service description) with code Z09 (cannot be offered) is not present. |
| [3] | If CCI+++Z64 is present |
| [4] | If present on the device and different from the device number |
| [5] | If in the same SG27 LIN the article number 9990001000649 is present |
| [8] | If SG28 CCI+++E13 CAV+EHZ is present |
| [10] | If SG28 CAV+MIW/MPW/MBW present |
| [22] | If CCI+++Z75 is present |
| [25] | If SG28 CCI+++E13 CAV+MME is present |
| [31] | Only the article numbers are permitted that are marked with the corresponding check identifier in the code list of article numbers of the BDEW. |
| [72] | if the code EM is present in DE3155 in the same COM |
| [73] | if the code TE / FX / AJ / AL is present in DE3155 in the same COM |
| [79] | If IMD DE7081 (product/service description) with value Z07 (purchase) is present. |
| [80] | If IMD DE7081 (product/service description) with value Z08 (provision for use) is present. |
| [492] | if MP-ID in NAD+MR from division electricity |
| [493] | if MP-ID in NAD+MR from division gas |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that. |
| [500] | Note: Indication of a technical contact person for the device takeover |
| [502] | Note: Use of the ID of the metering location |
| [504] | Note: Value from BGM+311 DE1004 of the REQOTE with which the quotation request was made. |
| [516] | Note: Only one piece of information may be transmitted in DE3148 |
| [908] | Format: possible values: 1 to n |
| [911] | Format: Possible values: 1 to n, starting at 1 for each message or segment group and ascending consecutively |
| [912] | Format: max. 6 decimal places |
| [914] | Format: Possible value: > 0 |
| [931] | Format: ZZZ = +00 |
| [939] | Format: the character string must contain the characters @ and . |
| [940] | Format: the character string must begin with the character + and may only be followed by digits |
| [951] | Format: Metering point identifier |
| [UB3] | ([931] ∧ [932] [492] ∧ [490]) ⊻ ([931] ∧ [933] [492] ∧ [491]) ⊻ ([931] ∧ [934] [493] ∧ [490]) ⊻ ([931] ∧ [935] [493] ∧ [491]) |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
Example message
Example 1
UNA:+.? '
UNB+UNOC:3+9906464000001:500+9904446000007:500+{{date}}:{{time}}+MC1KD4Q0'
UNH+UNHMCEYDAOS+QUOTES:D:10A:UN:1.3b'
BGM+310+BGMMCM3BZLS'
DTM+137:202510080800?+00:303'
DTM+76:202509302200?+00:303'
IMD++Z07'
RFF+AAV:REQOTE123456'
RFF+Z13:15001'
CUX+2:EUR:4'
NAD+MS+9906464000001::293'
CTA+IC+:Mustermann'
COM+?+012345678910:TE'
NAD+MR+9904446000007::293'
NAD+DP'
LOC+172+DE0032106765712000000000000001234'
LIN+1++9990001000649:Z01'
DTM+94:2025:602'
DTM+Z04:2033:602'
GIN+BN+SERIAL123456'
FTX+ACB+++weil ich das so sage'
CCI+++E13'
CAV+MME:::Z04'
CAV+ETZ'
CAV+ERZ'
CCI+++Z28'
CAV+BKE'
CCI+++E12'
CAV+MMR'
PRI+CAL:100:::1:H87'
RFF+Z09:1ESY0012345678'
RFF+APF:1:2:3'
LIN+2++9990001000657:Z01'
DTM+Z03:2025:602'
CCI+++Z25'
CAV+MIW:::50'
PRI+CAL:300:::2:H87'
RFF+Z09:WANDLER1'
RFF+Z09:WANDLER2'
LIN+3++9990001000772:Z01'
IMD++Z09'
NAD+VY+9904858000009::293'
LIN+4++9990001000665:Z01'
DTM+94:2025:602'
GIN+BN+SERIAL777777'
CCI+++Z26'
CAV+LTE'
PRI+CAL:1:::100:H87'
RFF+Z09:LTE123'
UNS+S'
UNT+49+UNHMCEYDAOS'
UNZ+1+MC1KD4Q0'[1 item
{6 fields
"data": {3 fields
"stammdaten": {4 fields
"MESSLOKATION": [1 item
{4 fields
"ANFRAGE": [1 item
{5 fields
"ANGEBOT": [1 item
{7 fields
"gesamtkosten": {1 field
"positionsdaten": [4 items
{5 fields
"positionspreis": [1 item
{3 fields
"verweisKatalognummer": {3 fields
{3 fields
"positionspreis": [1 item
{3 fields
{4 fields
"beteiligterMarktpartner": {5 fields
{3 fields
"positionspreis": [1 item
{3 fields
"ZAEHLER": [1 item
{14 fields
"geraete": [3 items
{3 fields
"weitereGeraetenummern": [1 item
"geraeteeigenschaften": {4 fields
{1 field
"geraeteeigenschaften": {1 field
{2 fields
"geraeteeigenschaften": {4 fields
"transaktionsdaten": {9 fields
"absender": {5 fields
"ansprechpartner": {4 fields
"rufnummern": [1 item
{2 fields
"empfaenger": {4 fields
Download: EDIFACT file · BO4E JSON
Example 2
UNA:+.? '
UNB+UNOC:3+9906464000001:500+9904446000007:500+{{date}}:{{time}}+MCVYAG0T'
UNH+UNHMCD6T51U+QUOTES:D:10A:UN:1.3b'
BGM+310+BGMMCM3BZLS'
DTM+137:202506170800?+00:303'
DTM+76:202506302200?+00:303'
IMD++Z07'
RFF+AAV:REQOTE123456'
RFF+Z13:15001'
CUX+2:EUR:4'
NAD+MS+9906464000001::293'
CTA+IC+:Mustermann'
COM+012345678910:TE'
NAD+MR+9904446000007::293'
NAD+DP'
LOC+172+DE0032106765712000000000000001234'
LIN+1++9990001000649:Z01'
DTM+94:2023:602'
DTM+Z04:2033:602'
GIN+BN+SERIAL123456'
FTX+ACB+++Allgemeine Informationen'
CCI+++E13'
CAV+MME:::Z04'
CAV+ETZ'
CAV+ERZ'
CCI+++Z28'
CAV+BKE'
CCI+++E12'
CAV+MMR'
PRI+CAL:100:::1:H87'
RFF+Z09:1ESY0012345678'
RFF+APF:1:2:3'
LIN+2++9990001000657:Z01'
DTM+Z03:2022:602'
CCI+++Z25'
CAV+MIW:::50'
PRI+CAL:300:::2:H87'
RFF+Z09:WANDLER1'
RFF+Z09:WANDLER2'
LIN+3++9990001000665:Z01'
DTM+94:2021:602'
GIN+BN+SERIAL777777'
CCI+++Z26'
CAV+DSL'
PRI+CAL:1:::100:H87'
RFF+Z09:LTE123'
LIN+4++9990001000673:Z01'
DTM+94:2020:602'
CCI+++Z27'
CAV+RSU'
PRI+CAL:50:::1:H87'
RFF+Z09:RSU123'
LIN+5++9990001000699:Z01'
DTM+94:2022:602'
PRI+CAL:1:::1:H87'
RFF+Z09:ABC123'
LIN+6++9990001000772:Z01'
DTM+Z03:2020:602'
DTM+Z04:2033:602'
CCI+++Z75'
PRI+CAL:1:::1:H87'
RFF+Z09:SMG12345'
LIN+7++9990001000780:Z01'
DTM+94:2020:602'
CCI+++Z76'
PRI+CAL:2:::1:H87'
UNS+S'
UNT+66+UNHMCD6T51U'
UNZ+1+MCVYAG0T'[1 item
{6 fields
"data": {3 fields
"stammdaten": {4 fields
"MESSLOKATION": [1 item
{4 fields
"ANFRAGE": [1 item
{3 fields
"ANGEBOT": [1 item
{7 fields
"gesamtkosten": {1 field
"positionsdaten": [7 items
{5 fields
"positionspreis": [1 item
{3 fields
"verweisKatalognummer": {3 fields
{3 fields
"positionspreis": [1 item
{3 fields
{3 fields
"positionspreis": [1 item
{3 fields
{3 fields
"positionspreis": [1 item
{3 fields
{3 fields
"positionspreis": [1 item
{3 fields
{3 fields
"positionspreis": [1 item
{3 fields
{3 fields
"positionspreis": [1 item
{3 fields
"ZAEHLER": [1 item
{14 fields
"geraete": [6 items
{3 fields
"weitereGeraetenummern": [1 item
"geraeteeigenschaften": {4 fields
{2 fields
"geraeteeigenschaften": {4 fields
{2 fields
"geraeteeigenschaften": {3 fields
{2 fields
"geraeteeigenschaften": {2 fields
{2 fields
"geraeteeigenschaften": {3 fields
{1 field
"geraeteeigenschaften": {2 fields
"transaktionsdaten": {9 fields
"absender": {6 fields
"ansprechpartner": {4 fields
"rufnummern": [1 item
{2 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected is MSB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| MSB | MSBA | Device takeover | AWH WiM gas 2.0 | Gas | Step 2 |
| MSB | MSBA | Device takeover | WiM electricity part 1 | Electricity | Step 2 |
| MSB | MSBN | Device takeover | AWH WiM gas 2.0 | Gas | Step 2 |
| MSB | MSBN | Device takeover | WiM electricity part 1 | Electricity | Step 2 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Quotation for device takeover |
| AHB | QUOTES AHB |
| Transmission channel | AS4 |
This check identifier is used in 3 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| WiM gas | Ch. B 5.2.3 No. 2 | MSBA → MSBN | Device takeover quotation |
| WiM electricity part 1 | Device takeover | MSB (corresponds to MSBA on the object metering location) → MSB (corresponds to MSBN on the object metering location) | Device takeover quotation |
| AWH WiM gas 2.0 | Device takeover | MSBA → MSBN | Device takeover quotation |
Further relationships from format version 202610
Version 202610 also carries this check identifier in contexts that the table of version 202604 does not know; they are included in the list above. Everything else on this page — use case, rulebook and communication direction — comes from the page's own version. Before adopting it into an implementation specification, check whether what is stated applies to 202604.
Transaction and responses
Role of this check identifier: request. Basis: the transaction data carry neither antwortstatus nor antwortstatusCodeliste, and neither the title nor the action of the Prüfi table begins with “response” or “response message”.
Responses: No response of this format version names this check identifier as a reference — neither explicitly in the Prüfi table nor via the step sequence. That does not mean there is none; it means that the sources do not record one.
Check identifiers of the same AHB table: No other check identifier of message type QUOTES has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 200 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains 2 transactions for this check identifier under the message type quotes. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.