Conditions QUOTES
EDIFACT message type QUOTES · format version 202604 · 129 conditions · 1 packages · 2 UB conditions · from 5 handbook file(s)
Conditions
| Marker | Condition |
|---|---|
| [1] | If the item cannot be offered because legal provisions or third-party rights preclude this |
| [2] | If in the same SG27 LIN IMD DE7081 (product/ service description) with code Z09 (cannot be offered) is not present. |
| [3] | If CCI+++Z64 is present |
| [4] | If present on the device and different from the device number |
| [5] | If in the same SG27 LIN the article number 9990001000649 is present |
| [8] | If SG28 CCI+++E13 CAV+EHZ is present |
| [9] | If in the same SG27 LIN the article number 9990001000657 is present |
| [10] | If SG28 CAV+MIW/MPW/MBW present |
| [11] | If in the same SG27 LIN the article number 9990001000665 is present |
| [12] | If in the same SG27 LIN the article number 9990001000673 is present |
| [13] | If present on the device |
| [15] | If in the same SG27 LIN the article number 9990001000772 is present |
| [16] | If in the same SG27 LIN the article number 9990001000780 is present |
| [17] | If the quotation was requested via REQOTE |
| [18] | If the quotation covers several market locations that have the identical connection user and whose metering classification is iMS (market location from SG11 LOC+172 and all market locations listed in a SG29 RFF+Z18). |
| [20] | If IMD++Z33 present |
| [21] | If IMD++Z34 present |
| [22] | If CCI+++Z75 is present |
| [25] | If SG28 CCI+++E13 CAV+MME is present |
| [26] | If DTM+203 not present |
| [27] | If DTM+469 not present |
| [28] | If RFF+AAV present |
| [29] | If DTM+469 was present in the request (REQOTE) |
| [30] | If SG27 IMD+Z09 is present |
| [31] | Only the article numbers are permitted that are marked with the corresponding check identifier in the code list of article numbers of the BDEW. |
| [39] | MP-ID only from division electricity |
| [44] | If MSBA is not the owner of the device/devices |
| [49] | If SG27 LIN++Z64 (Required product switching time definitions) is present |
| [50] | If SG27 LIN++Z65 (Required product power curve definitions) is present |
| [51] | If SG27 LIN++Z66 (Required product ad hoc control channel) is present |
| [52] | If SG27 LIN++Z67 (Required metering product for values of type 2 from backend) is present |
| [53] | If SG27 LIN++Z68 (Required product configuration permission for values of type2 from SMGW) is present |
| [54] | If present in the request for the quotation of a configuration |
| [55] | If the ID of a market location is specified in LOC+172 DE3225 (reporting point). |
| [56] | If the ID of a metering location is specified in LOC+172 DE3225 (reporting point). |
| [57] | If the ID of a grid location is specified in LOC+172 DE3225 (reporting point). |
| [58] | If the ID of a controllable resource is specified in LOC+172 DE3225 (reporting point). |
| [59] | Only the configuration products are permitted that are contained in chapter 4.1 „Configuration products switching time definition“ of the code list of configurations. |
| [60] | Only the configuration products are permitted that are contained in chapter 4.2 „Configuration products power curve definition“ of the code list of configurations. |
| [61] | Only the configuration products are permitted that are contained in chapter 4.3 „Configuration products ad-hoc- control channel“ of the code list of configurations. |
| [62] | Only the metering products are permitted that are contained in chapter 4.5 „Metering products for values according to type 2 from the backend for LF and NB“ of the code list of configurations. |
| [63] | Only the metering products are permitted that are contained in chapter 4.4 „Metering products with configuration permission for values according to type 2 from SMGW“ of the code list of configurations. |
| [65] | If DTM+203 (execution date) in DE2380 < 202312312300?+00 |
| [66] | If DTM+469 (start at the (earliest possible date)) in DE2380 < 202312312300?+00 |
| [67] | If DTM+203 (execution date) in DE2380 ≥ 202312312300?+00 |
| [68] | If DTM+469 (start at the (earliest possible date)) in DE2380 ≥ 202312312300?+00 |
| [69] | Only values from the EDI@Energy code list of article numbers and article IDs that are stated in chapter 3.5 "Billing of metering point operation for the electricity division" are permitted. |
| [70] | Only the metering product position codes are permitted that are contained in chapter 4.7 „Type of values for metering products according to type 2“ of the code list of configurations. |
| [71] | If within the same SG27 LIN a product is specified in PIA+5 DE7140 (Required product configuration permission for values of type 2 from SMGW) that is marked in the code list of configurations in chapter 4.4 „Metering products with configuration permission for values of type 2 from SMGW“ in the column "Trigger" with the value "When falling below / exceeding the threshold value". |
| [72] | if the code EM is present in DE3155 in the same COM |
| [73] | if the code TE / FX / AJ / AL is present in DE3155 in the same COM |
| [74] | Only the metering products are permitted that are contained in chapter 4.6.1 "Values according to type 2 from the backend" of the code list of configurations. |
| [75] | Only the metering products are permitted that are contained in chapter 4.6.2 "Values according to type 2 from SMGW" of the code list of configurations. |
| [77] | If the request for values contained a metering product which is contained in the code list of configurations in chapter 4.6.1 "Values according to type 2 from backend". |
| [78] | If the request for values contained a metering product which is contained in the code list of configurations in chapter 4.6.2 "Values according to type 2 from SMWG". |
| [79] | If IMD DE7081 (product/service description) with value Z07 (purchase) is present. |
| [80] | If IMD DE7081 (product/service description) with value Z08 (provision for use) is present. |
| [81] | If IMD DE7081 (product/service description) with value Z33 (quotation on the basis of a price sheet) is present. |
| [82] | If IMD DE7081 (product/service description) with value Z34 (individual quotation) is present. |
| [83] | If in the same SG27 LIN a PIA+Z02 (article ID) with an article ID in DE7140 whose last two digits have the value "01" (costs for setting up the metering product) is present. |
| [84] | If in the same SG27 LIN a PIA+Z02 (article ID) with an article ID in DE7140 whose last two digits have the value "02" (costs for operating the metering product) is present. |
| [85] | If in the same SG27 LIN a PIA+Z02 (article ID) with an article ID in DE7140 whose last two digits have the value "03" (costs for the transactions incurred for the metering product) is present. |
| [86] | If in the same SG31 PRI (price specification for the item) the DE5387 with the value Z01 (setup price) is present. |
| [87] | If in the same SG31 PRI (price specification for the item) the DE5387 with the value Z02 (transaction price) is present. |
| [88] | If in the same SG31 PRI (price specification for the item) the DE5387 with the value Z03 (operating price) is present. |
| [90] | Only the product codes are permitted that are present with the value "Metering location" in the column "Level" in chapter 7 "Products for the order placement of a change at a location" of the code list of configurations. |
| [91] | Only the product codes are permitted that are present with the value "Grid location" in the column "Level" in chapter 7 "Products for the order placement of a change at a location" of the code list of configurations. |
| [92] | Only the product codes are permitted that are present with the value "Controllable resource" in the column "Level" in chapter 7 "Products for the order placement of a change at a location" of the code list of configurations. |
| [93] | If RNG+Z03 (binding quantity specification) not present in this SG31 |
| [94] | If RNG+Z04 (non-binding quantity specification) not present in this SG31 |
| [490] | if the value in this DE, at position CCYYMMDDHHMM, is a point in time within the period stated in the table in chapter 3.5 “Overview of German statutory summer time (MESZ)” in the columns: “Summer time (MESZ) from” representation in UTC and “Summer time (MESZ) to” representation in UTC. |
| [491] | if the value in this DE, at position CCYYMMDDHHMM, is a point in time within the period stated in the table in chapter 3.6 “Overview of German statutory time (MEZ)” in the columns: “Winter time (MEZ) from” representation in UTC and “Winter time (MEZ) to” representation in UTC. |
| [492] | if MP-ID in NAD+MR from division electricity |
| [493] | if MP-ID in NAD+MR from division gas |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that. |
| [500] | Note: Indication of a technical contact person for the device takeover |
| [501] | Note: Use of the ID of the market location |
| [502] | Note: Use of the ID of the metering location |
| [503] | Note: The MP-ID of the owner (MSB) must be specified for bilateral clarification if, for example, the MSBA has leased the device / the devices itself. |
| [504] | Note: Value from BGM+311 DE1004 of the REQOTE with which the quotation request was made. |
| [505] | Note: Value from BGM+Z29 DE1004 of the REQOTE with which the request for invoice processing was made. |
| [506] | Note: If several device numbers exist for one item (e.g. instrument transformer set), the device numbers must be stated in the same item (LIN segment) by repeating the SG32 RFF+Z09 |
| [507] | Note: Use of the ID of the tranche |
| [511] | Note: Value from BGM+Z74 (order placement for a quotation for a configuration) DE1004 of the REQOTE with which the request for a configuration was made. |
| [512] | Note: Use of the ID of the grid location |
| [513] | Note: Use of the ID of the controllable resource |
| [514] | Note: Indication in accordance with the price sheet of the MSB. Up to once for the parameterization, up to once for the operation and up to once for the transaction, provided it is contained in the price sheet of the MSB. |
| [516] | Note: Only one piece of information may be transmitted in DE3148 |
| [517] | Note: Value from BGM+Z93 (order placement for a quotation for the change of the technology of the location) DE1004 of the REQOTE with which the request for a quotation for the change of technology was made. |
| [518] | Note: Indication in accordance with price sheet B of the MSB. |
| [519] | Note: Value from BGM DE1004 of the PRICAT with which price sheet B of the MSB on which this quotation is based was transmitted. |
| [520] | Note: Statement of the start point in time of the expected earliest implementation date that can be determined at the point in time when the quotation is drawn up. |
| [521] | Note: Indication of the end point in time of the expected earliest implementation date that can be determined at the point in time when the quotation is created.. |
| [903] | Format: Possible value: 1 |
| [906] | Format: max. 3 decimal places |
| [908] | Format: possible values: 1 to n |
| [911] | Format: Possible values: 1 to n, starting at 1 for each message or segment group and ascending consecutively |
| [912] | Format: max. 6 decimal places |
| [914] | Format: Possible value: > 0 |
| [931] | Format: ZZZ = +00 |
| [932] | Format: HHMM = 2200 |
| [933] | Format: HHMM = 2300 |
| [934] | Format: HHMM = 0400 |
| [935] | Format: HHMM = 0500 |
| [939] | Format: the character string must contain the characters @ and . |
| [940] | Format: the character string must begin with the character + and may only be followed by digits |
| [942] | Format: n1-n2-n1-n3 |
| [950] | Format: market location ID |
| [951] | Format: Metering point identifier |
| [959] | Format: n13-n2 |
| [960] | Format: Grid location ID |
| [961] | Format: SR-ID |
| [962] | Format: max. 6 digits before the decimal point |
| [2042] | Within this LIN line item, the PIA+Z02 (article ID) must be specified at least once and can be specified up to three times. |
| [2060] | The SG27 LIN+Z64 (required product switching time definitions) must be specified at most once per message |
| [2061] | The SG27 LIN++Z65 (required product load curve definitions) must be specified at most once per message |
| [2062] | The SG27 LIN++Z66 (required product ad-hoc control channel) must be specified at most once per message |
| [2063] | The SG27 LIN++Z67 (required metering product for values according to type 2 from the backend) must be specified at most once per message |
| [2064] | The SG27 LIN++Z68 (required product configuration permission for values according to type 2 from SMGW) must be specified at most once per message |
| [2066] | This SG28 must be repeated as many times as a product is stated for the different metering product item codes for the product stated in PIA+5 DE7140 (required product configuration permission for values of type 2 from SMGW) within the same SG27 LIN, which is marked in the code list of configurations in chapter 4.4 "Metering products with configuration permission for values of type 2 from SMGW" in the column "trigger" with the value "When falling below / exceeding the threshold value". |
| [2068] | The SG31 PRI must be specified exactly once per SG27 LIN. |
| [2069] | The SG31 PRI must be specified exactly once per SG27 LIN. In this case, a quantity specification with the code H87 (piece) in DE6411 must be stated in DE5284 of the SG31 PRI. |
| [2070] | The SG31 PRI must be specified twice per SG27 LIN. In this case, exactly one SG31 PRI with price and quantity specification and the code H87 (piece) in DE6411 and exactly one SG31 PRI with price and quantity specification and the code DAY (day) in DE6411 must be present. |
| [2071] | This SG31 PRI (price specification for the item) must be stated up to three times. It must be stated as many times as the PIA+Z02 (article ID) is present within the same SG27 LIN (required metering product for values of type 2 from backend). |
| [2072] | This SG31 PRI (price specification for the item) must be stated up to three times. It must be stated as many times as the PIA+Z02 (article ID) is present within the same SG27 LIN (required product configuration permission for values of type 2 from SMGW). |
| [2073] | The PIA (OBIS code for values according to Type 2 backend) must be specified at least once. Depending on the other PIA segments within the same SG27 LIN (required metering product for values according to Type 2 from the backend), it can be specified up to a maximum of 23 times, provided that the other PIA segments within the same SG27 LIN are specified no more than once. The maximum number of PIA segments per SG27 LIN is 25. |
| [2074] | Per message, this SG27 must be repeated until a quotation line item has been specified for every requested product of the same SG27 from the request. |
| [2075] | The SG27 PIA+Z02 (article ID) can be specified up to twice per SG27 LIN. Once for the article ID according to price sheet B of the MSB and once for the article ID "9991000003030-01" (flat-rate costs for the failure of the change of technology at a location) according to price sheet B of the MSB. If the MSB has not stated an article ID for "9991000003030-01" (flat-rate costs for the failure of the change of technology of a location) in the stated version of price sheet B, the SG27 PIA+Z02 (article ID) can be specified only once. |
| [2076] | The SG31 price specification for the line item can be specified only once per SG27 LIN. The price specification for the line item refers to the article ID that is not the article ID "9991000003030- 01" (flat-rate costs for the failure of the change of technology at a location) according to price sheet B of the MSB. |
UB conditions
UB conditions combine several markers into a single expression. In the handbook rows they appear like a condition, but they resolve into the markers they contain.
| Marker | Printout |
|---|---|
| [UB1] | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |
| [UB3] | ([931] ∧ [932] [492] ∧ [490]) ⊻ ([931] ∧ [933] [492] ∧ [491]) ⊻ ([931] ∧ [934] [493] ∧ [490]) ⊻ ([931] ∧ [935] [493] ∧ [491]) |
Condition packages
Condition packages bundle prerequisites.
| Package | Prerequisites | Conditions |
|---|---|---|
| [1P] | -- | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
Notes on this page
This page carries the free text of every condition that the application handbook of message type QUOTES references in this format version. A row of the handbook writes Muss [704]; what [704] requires is here.
The list applies to the message type, not to a single check identifier. This is not a simplification but the form of the source: the condition list is present identically in every handbook file of the format.
Why no assignment to individual check identifiers is given here
The intermediate format from which this documentation reads the handbook rows assigns conditions to a column — and this assignment is shifted against the original. Measured on 05.09.2026 against UTILMD electricity: the handbook lists STS DE9013 as X [360] (approval codes only) for check identifier 55017 and X [359] (rejection codes only) for 55018; the intermediate format puts [360] on 55016 and [359] on 55017 and 55018. The same applies to FTX Muss [83]: at 55018 in the handbook, at 55017 in the intermediate format.
Independently confirmed by the change lists of the source: change IDs 25242, 25821, 25822, 25445 and 25243 explicitly locate [83], [351] and [352] in „Use case 55018 Rejection of contract termination“. No entry assigns them to 55016 or 55017.
That is why the text of every condition is given here and nowhere the claim as to which condition applies to which check identifier. Anyone who needs that looks it up in the original application handbook.
2 conditions do not appear in every handbook file
The list of conditions is meant to apply across the whole format, but it does not everywhere: the following markers occur in fewer than all 5 files of this format. They are given here nonetheless — leaving out a condition because one file does not carry it would mean letting a reference point into the void again.
[UB1], [UB3]
As measured on 05.09.2026, no ahb_expression in this source points to a package marker — the condition packages are listed on this page because the source carries them, not because a handbook line refers to them.