Conditions ORDRSP
EDIFACT message type ORDRSP · format version 202604 · 122 conditions · 1 packages · 2 UB conditions · from 40 handbook file(s)
Conditions
| Marker | Condition |
|---|---|
| [1] | If BGM+7 present |
| [3] | If MP-ID in SG3 NAD+MS with role NB is present |
| [4] | If MP-ID in SG3 NAD+MR with role LF is present |
| [5] | If MP-ID in SG3 NAD+MS with role LF is present |
| [7] | If MP-ID in SG3 NAD+MR from division Electricity |
| [9] | If MP-ID in SG3 NAD+MS with role LF is present |
| [10] | If MP-ID in SG3 NAD+MS with role MSB is present |
| [11] | If AJT+A09+E_0470 present |
| [12] | If the NB can state a non-binding price indication |
| [13] | If MP-ID in SG3 NAD+MR from division Gas |
| [14] | If MP-ID in SG3 NAD+MR with role MSB is present |
| [15] | If MP-ID in SG3 NAD+MR with role NB is present |
| [16] | If MP-ID in SG3 NAD+MR with role ÜNB is present |
| [17] | The check step code specified here must be assigned in EBD to the cluster consent |
| [18] | The check step code specified here must be assigned in EBD to the cluster rejection |
| [21] | If IMD++Z01 present |
| [22] | If IMD++Z02 present |
| [23] | If IMD++Z03 present |
| [24] | If BGM+Z51 present |
| [25] | If BGM+Z52 present |
| [27] | If AJT+A05+E_0470 present |
| [28] | If AJT+A99 present |
| [29] | MP-ID only from division gas |
| [30] | MP-ID only from division electricity |
| [31] | MP-ID with role MSB |
| [32] | MP-ID with role NB |
| [33] | If AJT+A02/A03+E_0488 present |
| [34] | if present |
| [37] | If the SG8 CUX+2 is present in this message |
| [38] | Possible value: ZB4 or ZB5 |
| [39] | Possible value: E17 or Z07 |
| [40] | If the code in DE3207 contains an "X" in the column "PLZ present" of the "EDI@Energy code list of European country codes" |
| [41] | if SG2 AJT (details of an adjustment/change) DE4465 with value ZB5 is present |
| [42] | If SG2 AJT+Z07 (response category: rejection (no authorization)) is present |
| [43] | If AJT+A02/A03+E_1001 present |
| [44] | If AJT+A05+E_1000 present |
| [45] | If AJT+A09+E_1000 present |
| [46] | If AJT+A06+E_0552 present |
| [47] | If AJT+A06+E_0553 present |
| [48] | If AJT+A06+E_0554 present |
| [49] | only if IMD++Z60 (order cancellation of metering product with metering time period definition of the LF) was present in the original message |
| [50] | if the code EM is present in DE3155 in the same COM |
| [51] | if the code TE / FX / AJ / AL is present in DE3155 in the same COM |
| [52] | if the complaint was a complaint about the rolled-out load curve definitions |
| [53] | Transaction number from IDE DE7402 of the UTILTS with BGM+Z59 |
| [54] | Transaction number from IDE DE7402 of the UTILTS with BGM+Z80 |
| [55] | Transaction number from IDE DE7402 of the UTILTS with BGM+Z81 |
| [56] | if SG2 AJT+A02/A03/A06/A07/A10/A11+E_0548 is present |
| [57] | if SG2 AJT+A02/A03/A06/A07/A10/A11+E_0549 is present |
| [58] | if SG2 AJT+A02/A03/A06/A07+E_0550 is present |
| [59] | if SG2 AJT+A02/A03/A06/A07/A10/A11+E_0551 is present |
| [60] | if the complaint was a complaint about the overview of metering time definitions |
| [61] | if the complaint was a complaint about the overview of switching time definitions |
| [62] | if the complaint was a complaint about the overview of load curve definitions |
| [63] | Document number from BGM+Z60 DE1004 of the UTILTS |
| [64] | Document number from BGM+Z78 DE1004 of the UTILTS |
| [65] | Document number from BGM+Z79 DE1004 of the UTILTS |
| [66] | if SG2 AJT+A01/A02/A03+E_0544 is present |
| [67] | if SG2 AJT+A01/A02/A03+E_0545 is present |
| [68] | if SG2 AJT+A02/A03+E_0546 is present |
| [69] | if SG2 AJT+A01/A02/A03+E_0547 is present |
| [70] | if the complaint was a complaint about the rolled-out metering time definitions |
| [71] | if the complaint was a complaint about the rolled-out switching time definitions |
| [72] | if AJT+A04+E_0552 is present |
| [73] | if AJT+A04+E_0553 is present |
| [74] | if AJT+A04+E_0554 is present |
| [75] | If this is the response to an order placement in which a metering product from the code list of configurations from chapter 4.6.2 „Values according to type 2 from SMGW“ was ordered. |
| [76] | If FTX+Z27 (IP address of the sender) not present |
| [77] | If FTX+Z28 (IP range of the sender) not present |
| [78] | If AJT+A04+E_0279 present |
| [79] | If AJT+A04+E_0283 present |
| [80] | If AJT+A05+E_0279 present |
| [81] | If AJT+A05+E_0283 present |
| [82] | If BGM+Z93 (order placement for an offer for change of the technology of the location) present |
| [83] | If BGM+Z12 (change of the technology of the location) present |
| [490] | if the value in this DE, at position CCYYMMDDHHMM, is a point in time within the period stated in the table in chapter 3.5 “Overview of German statutory summer time (MESZ)” in the columns: “Summer time (MESZ) from” representation in UTC and “Summer time (MESZ) to” representation in UTC. |
| [491] | if the value in this DE, at position CCYYMMDDHHMM, is a point in time within the period stated in the table in chapter 3.6 “Overview of German statutory time (MEZ)” in the columns: “Winter time (MEZ) from” representation in UTC and “Winter time (MEZ) to” representation in UTC. |
| [492] | if MP-ID in NAD+MR from division electricity |
| [493] | if MP-ID in NAD+MR from division gas |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that. |
| [500] | Note: Indication of a technical contact person for the device takeover |
| [503] | Note: Date up to which the MSBA was obliged to continue |
| [504] | Note: Corrected where applicable in the case of a time specification in the ORDERS that lies outside the maximum possible continued obligation period. The response then states consent with date change in SG2 AJT. |
| [513] | Note: Value from BGM+Z12 (change of the technology of the location) DE1004 of the ORDERS with which the order placement was made. |
| [518] | Note: Value from BGM+Z10 DE1004 of the ORDERS with which the order placement was made |
| [519] | Note: Value from BGM+7 DE1004 of the ORDERS with which the order placement was made. |
| [520] | Note: Value from BGM+Z29 DE1004 of the ORDERS with which the request for the termination of invoice processing was made. |
| [521] | Note: Value from BGM+Z14/Z61/Z62 DE1004 of the ORDERS with which the request for master data was made |
| [522] | Note: Value from BGM+7/Z28/Z48 DE1004 of the ORDERS with which the request for values was made. |
| [523] | Note: Value from BGM+7 DE1004 of the ORDERS with which the request for calorific value and conversion factor was made. |
| [524] | Note: Value from BGM+Z14 DE1004 of the ORDERS with which the request from the MSB gas was made. |
| [525] | Note: Value from BGM+Z24 DE1004 of the ORDERS with which the request for the allocation list was made |
| [526] | Note: Value from BGM+Z23 DE1004 of the ORDERS with which the request for the balanced quantity was made |
| [527] | Note: Value from BGM+Z34 DE1004 of the ORDERS with which the complaint regarding values was made. |
| [529] | Note: Document number from BGM DE1004 of the ORDERS |
| [530] | Note: Document number from BGM DE1004 of the ORDCHG |
| [533] | Note: Value from BGM+Z51 DE1004 of the ORDCHG |
| [534] | Note: Value from BGM+Z52 DE1004 of the ORDCHG |
| [535] | Note: Value from BGM+Z13 DE1004 of the ORDERS with which the announcement of the device replacement intent was made. |
| [536] | Note: The MP-ID of the owner (MSB) must be specified for bilateral clarification if the requested MSB is not the owner itself. |
| [537] | Note: Value from BGM+Z72 DE1004 of the ORDERS with which the order placement for the termination of the configuration was made. |
| [538] | Note: Value from BGM+Z76 DE1004 of the ORDERS with which the complaint regarding the configuration was made. |
| [539] | Note: Value from BGM+Z73/Z74 DE1004 of the ORDERS with which the order placement for the configuration was made. |
| [540] | Note: Only one piece of information may be transmitted in DE3148 |
| [542] | Note: Value from BGM+Z91 DE1004 of the ORDERS with which the order placement for the change of the billing data was made. |
| [543] | Note: Value from BGM+Z93 (order placement for a quotation for the change of the technology of the location) DE1004 of the ORDERS with which the order placement was made. |
| [544] | Note: Value from BGM DE1004 of the PRICAT with which price sheet B of the MSB on which the quotation is based from the point of view of the MSB was transmitted. |
| [545] | Note: Statement of the start point in time of the realistically possible implementation date that can be determined at the point in time of the rejection. |
| [546] | Note: Indication of the end point in time of the realistically possible implementation date that can be determined at the point in time of the rejection. |
| [547] | Note: If this concerns the order placement of a previous quotation within the scope of the BDEW application guide "Processes for changing the technology at locations". |
| [548] | Note: Note: if it concerns the order issuance of a change in accordance with WiM Part1 UC "metering location change". |
| [902] | Format: Format: possible value: ≥ 0 |
| [903] | Format: Possible value: 1 |
| [930] | Format: max. 2 decimal places |
| [931] | Format: ZZZ = +00 |
| [932] | Format: HHMM = 2200 |
| [933] | Format: HHMM = 2300 |
| [934] | Format: HHMM = 0400 |
| [935] | Format: HHMM = 0500 |
| [939] | Format: the character string must contain the characters @ and . |
| [940] | Format: the character string must begin with the character + and may only be followed by digits |
| [2036] | The SG27 must be specified exactly once per message |
UB conditions
UB conditions combine several markers into a single expression. In the handbook rows they appear like a condition, but they resolve into the markers they contain.
| Marker | Printout |
|---|---|
| [UB1] | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |
| [UB3] | ([931] ∧ [932] [492] ∧ [490]) ⊻ ([931] ∧ [933] [492] ∧ [491]) ⊻ ([931] ∧ [934] [493] ∧ [490]) ⊻ ([931] ∧ [935] [493] ∧ [491]) |
Condition packages
Condition packages bundle prerequisites.
| Package | Prerequisites | Conditions |
|---|---|---|
| [1P] | -- | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
Notes on this page
This page carries the free text of every condition that the application handbook of message type ORDRSP references in this format version. A row of the handbook writes Muss [704]; what [704] requires is here.
The list applies to the message type, not to a single check identifier. This is not a simplification but the form of the source: the condition list is present identically in every handbook file of the format.
Why no assignment to individual check identifiers is given here
The intermediate format from which this documentation reads the handbook rows assigns conditions to a column — and this assignment is shifted against the original. Measured on 05.09.2026 against UTILMD electricity: the handbook lists STS DE9013 as X [360] (approval codes only) for check identifier 55017 and X [359] (rejection codes only) for 55018; the intermediate format puts [360] on 55016 and [359] on 55017 and 55018. The same applies to FTX Muss [83]: at 55018 in the handbook, at 55017 in the intermediate format.
Independently confirmed by the change lists of the source: change IDs 25242, 25821, 25822, 25445 and 25243 explicitly locate [83], [351] and [352] in „Use case 55018 Rejection of contract termination“. No entry assigns them to 55016 or 55017.
That is why the text of every condition is given here and nowhere the claim as to which condition applies to which check identifier. Anyone who needs that looks it up in the original application handbook.
8 conditions do not appear in every handbook file
The list of conditions is meant to apply across the whole format, but it does not everywhere: the following markers occur in fewer than all 40 files of this format. They are given here nonetheless — leaving out a condition because one file does not carry it would mean letting a reference point into the void again.
[490], [491], [932], [933], [934], [935], [UB1], [UB3]
As measured on 05.09.2026, no ahb_expression in this source points to a package marker — the condition packages are listed on this page because the source carries them, not because a handbook line refers to them.