Conditions REMADV
EDIFACT message type REMADV · format version 202610 · 131 conditions · 3 packages · 0 UB conditions · from 4 handbook file(s)
Conditions
| Marker | Condition |
|---|---|
| [2] | If SG7 AJT+28 is present |
| [3] | For SG5 DOC+389 / Z25, the value from the same SG5 MOA+9 is to be stated multiplied by (-1). |
| [4] | For SG5 DOC+380 / 457, the value from the same SG5 MOA+9 is to be stated unchanged. |
| [8] | If SG7 AJT+A01/A02+E_0505 present |
| [9] | If SG7 AJT+A32/A99+E_0503 present |
| [11] | If DE1082 = E_0406 in this AJT |
| [12] | If DE1082 = E_0407 in this AJT |
| [14] | A code from the rejection cluster at header level |
| [15] | A code from the rejection cluster at line item level |
| [16] | A code from the rejection cluster at summary level |
| [18] | If AJT DE4465 = A74/A75/A76/AC5 in this SG7 |
| [22] | If AJT DE4465 = A02/A06/A16/A66/A67/A68/A69/A78/A90/A95/A96/AC3/AC4 in this SG7 |
| [26] | If AJT DE4465 = A51/A62/A82/AA1/AA6/AA7/AB8/AD6 in this SG12 |
| [28] | If AJT DE4465 = A23/A26/A35/A36/A38/A46/A47/A48/A50/A58/A59/A61/A77/A84/A99 in this SG12 |
| [33] | If DE1082 = S_0103 in this AJT |
| [34] | If DE1082 = S_0104 in this AJT |
| [35] | If AJT DE4465 = A34/A39/AA2/AB2 in this SG12 |
| [36] | If AJT DE4465 = A12/A75/A80/AE1 in this SG7 |
| [39] | If AJT DE4465 = AC1 in this SG7 |
| [40] | If AJT DE1082 = E_0406 in this SG7 |
| [41] | If AJT DE1082 = E_0407 in this SG7 |
| [42] | If in SG7 AJT DE1082 = E_0407/E_0568/E_0521/E_0517/E_0266 |
| [43] | If AJT DE4465=28 in SG12 |
| [45] | Only MP-ID from the electricity division |
| [47] | If DE1082 = E_0210 in this AJT |
| [48] | If DE1082 = E_0259 in this AJT |
| [49] | If AJT DE4465 = A01/A05/A22/A23/A90/A96 in this SG7 |
| [50] | If AJT DE4465 = A01/A05/A18/A19/A20/A90/A96 in this SG7 |
| [51] | If AJT DE1082 = E_0406 in this SG12 |
| [52] | If AJT DE1082 = E_0407 in this SG12 |
| [53] | If AJT DE4465 = A25/A31/A99/AF1 in this SG12 |
| [54] | If AJT DE1082 = E_0210 in this SG12 |
| [55] | If AJT DE1082 = E_0259 in this SG12 |
| [56] | If AJT DE4465 = A21 in this SG7 |
| [57] | If AJT DE1082 = E_0210 in this SG7 |
| [58] | If AJT DE1082 = E_0259 in this SG7 |
| [59] | If SG7 AJT+A08/A99+E_0459 present |
| [60] | If SG7 AJT+A99+E_0243 present |
| [61] | If SG7 AJT+A99+E_0261 present |
| [62] | If SG7 AJT+A99+E_1007 present |
| [63] | If SG7 AJT+A01/A02+E_1009 present |
| [64] | If AJT DE1082 = E_0264 in this SG12 |
| [65] | If AJT DE1082 = E_0515 in this SG12 |
| [66] | If AJT DE1082 = E_0519 in this SG12 |
| [67] | If AJT DE1082 = E_0266 in this SG12 |
| [68] | If AJT DE1082 = E_0517 in this SG12 |
| [69] | If AJT DE1082 = E_0521 in this SG12 |
| [70] | If AJT DE4465 = A15 in this SG12 |
| [71] | If AJT DE4465 = A99 in this SG12 |
| [72] | If SG7 AJT+A99+E_0518 present |
| [73] | If SG7 AJT+A99+E_0522 present |
| [74] | If SG7 AJT+A99+E_0267 present |
| [75] | If DE1082 = E_0264 in this AJT |
| [76] | If DE1082 = E_0266 in this AJT |
| [77] | If DE1082 = E_0515 in this AJT |
| [78] | If DE1082 = E_0517 in this AJT |
| [79] | If DE1082 = E_0519 in this AJT |
| [80] | If DE1082 = E_0521 in this AJT |
| [81] | If AJT DE1082 = E_0264 in this SG7 |
| [82] | If AJT DE1082 = E_0515 in this SG7 |
| [83] | If AJT DE1082 = E_0519 in this SG7 |
| [84] | If AJT DE1082 = E_0266 in this SG7 |
| [85] | If AJT DE1082 = E_0517 in this SG7 |
| [86] | If AJT DE1082 = E_0521 in this SG7 |
| [87] | If AJT DE4465 = A05/A21/A22/A23/A90/A96/AE7 in this SG7 |
| [88] | If AJT DE4465 = A25 in this SG7 |
| [89] | if the code EM is present in DE3155 in the same COM |
| [90] | if the code TE / FX / AJ / AL is present in DE3155 in the same COM |
| [91] | If DE1082 = E_0566 in this AJT |
| [92] | If DE1082 = E_0568 in this AJT |
| [93] | If SG7 AJT+A99+E_0804 present |
| [94] | If SG7 AJT+A99+E_0806 present |
| [95] | If SG7 AJT+A99+E_0569 present |
| [96] | If SG7 AJT+E_0503/E_1007 is present |
| [97] | If AJT DE4465 = A27 in this SG12 |
| [98] | If AJT DE1082 = E_0407 in SG12 |
| [99] | If AJT DE1082 = E_0568 in SG12 |
| [100] | If SG7 AJT+A01 is present |
| [101] | If AJT DE1082 = E_0566 in this SG7 |
| [102] | If AJT DE1082 = E_0568 in this SG7 |
| [103] | If AJT DE1082 = E_0566 in this SG12 |
| [104] | If AJT DE1082 = E_0568 in this SG12 |
| [105] | If DE1082 = E_0270 in this AJT |
| [106] | If DE1082 = E_0273 in this AJT |
| [107] | If DE1082 = E_0276 in this AJT |
| [108] | If DE1082 = E_0277 in this AJT |
| [109] | If AJT DE4465 = A01/A21/A22/A23/A90/A96 in this SG7 |
| [110] | If AJT DE1082 = E_0270 in this SG7 |
| [111] | If AJT DE1082 = E_0273 in this SG7 |
| [112] | If AJT DE1082 = E_0276 in this SG7 |
| [113] | If AJT DE1082 = E_0277 in this SG7 |
| [114] | If AJT DE1082 = E_0270 in this SG12 |
| [115] | If AJT DE1082 = E_0273 in this SG12 |
| [116] | If AJT DE1082 = E_0276 in this SG12 |
| [117] | If AJT DE1082 = E_0277 in this SG12 |
| [118] | If SG7 AJT+A99+E_0272 present |
| [119] | If SG7 AJT+A99+E_0275 present |
| [120] | If AJT DE4465 = A01 in this SG7 |
| [121] | If SG7 AJT+A08/A99+E_3038 present |
| [492] | If MP-ID in NAD+MR (message recipient) from the Electricity division |
| [493] | If MP-ID in NAD+MR (message recipient) from the Gas division |
| [501] | Note: At this point, the amount from SG50 MOA+9 of the underlying INVOIC is to be adopted. |
| [502] | Note: A positive amount results in a receivable of the invoice issuer. A negative amount results in a receivable for the invoice recipient. |
| [503] | Note: Recommended in order to reach a contact person for queries in the event of a refusal. |
| [510] | Note: In the event of a rejection of a previous COMDIS |
| [511] | Note: BGM DE1004 from the rejected INVOIC message |
| [512] | Note: BGM DE1004 from the rejected COMDIS message |
| [515] | Note: BGM DE1004 from the confirmed INVOIC message |
| [517] | Note: If a code from the rejection cluster at summary level is used in AJT DE4465 of this SG5, this SG7 must be repeated until all errors at summary level have been stated. |
| [518] | Note: If a code from the rejection cluster at header level other than A80 is used in AJT DE4465 of this SG5, this SG7 must be used exactly once. |
| [519] | Note: This SG7 is to be repeated with AJT DE4465 = A74 until all invoice numbers are named in the RFF segment of this SG7 that are missing in the INVOIC named in this SG5 DOC DE1004 |
| [520] | Note: This SG7 is to be repeated with AJT DE4465 = A75 until all invoice numbers of the invoices are named that contain at least one instalment invoice and that were billed in the INVOIC named in this SG5 DOC DE1004. |
| [521] | Note: This SG7 is to be repeated with AJT DE4465 = A76 until all invoice numbers of the instalment invoices are named that should not have been taken into account in the INVOIC named in this SG5 DOC DE1004. |
| [523] | Note: Each invoice number of an instalment invoice must be stated in a separate DE4440. If the five DE4440 are not sufficient for the invoice numbers of all instalment invoices to be stated, FTX+Z14 must be repeated. |
| [525] | Note: This SG10 is to be repeated until all errors at line item level are named. |
| [526] | Note: Value from DE1082 of the SG26 in which the following error is located in the INVOIC that is stated in this SG5 DOC DE1004. |
| [529] | Note: If AJT DE4465 = A75 is present in this SG7, only advance payment invoice numbers may be stated in the DE4440 of this FTX segment that are contained in the invoice whose number is stated in this SG7 in SG7 RFF+AFL. |
| [533] | Note: If AJT DE4465 = AA1/AA6/AA7/AB8/AD6 in this SG12, this SG12 must be repeated with AJT DE4465 = code until all invoice numbers in the RFF segment of this SG12 have been stated. |
| [534] | Note: If AJT DE4465 = A34/A39/AA2/AB2 in this SG12, this SG12 must be repeated with AJT DE4465 = code until all numbers of the complaints in the RFF segment of this SG12 have been stated. |
| [535] | Note: This SG7 is to be repeated with AJT DE4465 = A80 until the invoice numbers of the non-canceled special invoices are named that have the same special invoice type as the one named in the special invoice named in this SG5 DOC DE1004, and that refer to the same invoice as the one named in this SG5 DOC DE1004. |
| [536] | Note: This DE must not contain an instalment invoice number |
| [537] | Note: This SG7 is to be repeated with AJT DE4465 = AC5 until all invoice numbers are named in the RFF segment of this SG7 that should have been taken into account in the INVOIC named in this SG5 DOC DE1004, but at least one of which evidently was not taken into account. |
| [538] | Note: Each item number of a quotation must be stated in a separate DE4440. If the five DE4440 are not sufficient for the item numbers of all quotations to be stated, SG7 FTX+Z16 must be repeated. |
| [544] | Note: If AJT DE4465 = A21 is present in this SG7, only one item number may be stated in each DE4440 of this FTX segment, namely those from the confirmed quotation that are not contained in the invoice. |
| [548] | Note: How the data element is filled results from the associated EBD. |
| [549] | Note: Only one piece of information may be transmitted in DE3148 |
| [926] | Format: Possible value: 0 |
| [930] | Format: max. 2 decimal places |
| [931] | Format: ZZZ = +00 |
| [939] | Format: the character string must contain the characters @ and . |
| [940] | Format: the character string must begin with the character + and may only be followed by digits |
Condition packages
Condition packages bundle prerequisites.
| Package | Prerequisites | Conditions |
|---|---|---|
| [1P] | -- | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
| [2P] | [492] | [492] If MP-ID in NAD+MR (message recipient) from division electricity |
| [3P] | [493] | [493] If MP-ID in NAD+MR (message recipient) from division gas |
Notes on this page
This page carries the free text of every condition that the application handbook of message type REMADV references in this format version. A row of the handbook writes Muss [704]; what [704] requires is here.
The list applies to the message type, not to a single check identifier. This is not a simplification but the form of the source: the condition list is present identically in every handbook file of the format.
Why no assignment to individual check identifiers is given here
The intermediate format from which this documentation reads the handbook rows assigns conditions to a column — and this assignment is shifted against the original. Measured on 05.09.2026 against UTILMD electricity: the handbook lists STS DE9013 as X [360] (approval codes only) for check identifier 55017 and X [359] (rejection codes only) for 55018; the intermediate format puts [360] on 55016 and [359] on 55017 and 55018. The same applies to FTX Muss [83]: at 55018 in the handbook, at 55017 in the intermediate format.
Independently confirmed by the change lists of the source: change IDs 25242, 25821, 25822, 25445 and 25243 explicitly locate [83], [351] and [352] in „Use case 55018 Rejection of contract termination“. No entry assigns them to 55016 or 55017.
That is why the text of every condition is given here and nowhere the claim as to which condition applies to which check identifier. Anyone who needs that looks it up in the original application handbook.
As measured on 05.09.2026, no ahb_expression in this source points to a package marker — the condition packages are listed on this page because the source carries them, not because a handbook line refers to them.