Conditions UTILMDS
EDIFACT message type UTILMDS · format version 202610 · 623 conditions · 38 packages · 1 UB conditions · from 189 handbook file(s)
Conditions
| Marker | Condition |
|---|---|
| [1] | If a split is present |
| [2] | If UNH DE0070 (transmission sequence number) with 1 is present |
| [3] | In the case of splitting, in the message with the highest transmission sequence number |
| [4] | If MP-ID in SG2 NAD+MR (message recipient) in the role LF |
| [5] | If MP-ID in SG2 NAD+MS (message sender) in the role LF |
| [6] | If MP-ID in SG2 NAD+MR (message recipient) in the role ÜNB |
| [7] | If SG4 STS+7++ZG9/ZH1/ZH2 (transaction reason: cancellation of a future assignment due to move-out of the customer / -due to decommissioning / -due to cancelled contractual relationship) is present |
| [8] | If required for data clearing |
| [9] | If MP-ID in SG2 NAD+MS (message sender) in the role MSB |
| [10] | If SG4 STS+7++xxx+xxx+E01/E03 (transaction reason fixed-term registration) is present |
| [11] | If SG4 STS+7++ZG9/ZH1/ZH2 (transaction reason: cancellation of a future assignment due to move-out of the customer / -due to decommissioning / -due to cancelled contractual relationship) is not present |
| [12] | If SG4 DTM+471 (end at the next possible date) is not present |
| [13] | If SG4 STS+E01++Z01 (status of the response: consent with change of date) is not present |
| [14] | If the date is known |
| [15] | If in the same SG8 the SEQ+Z98 (informative data of the market location) is present |
| [16] | If SG4 STS+E01++Z12 (status of the response: rejection contractual commitment) is present |
| [17] | If in the same SG8 the SEQ+Z01/Z80/Z81 (data of the market location) is present |
| [18] | If SG4 DTM+93 (end as of) is not present |
| [19] | If SG8 SEQ+Z01/Z98 (data of the market location) SG10 CCI+++ZC0 (forecast based on values) present |
| [20] | If, in the SG8 SEQ+Z01 (data of the market location) with the same ID in the SG8 RFF+Z18 (reference to the ID of the market location) as in this SG8, the SG10 CCI+Z30++Z07 (consumption) is present |
| [21] | If SG10 CCI+++ZA6 (forecast based on profiles) present in this SG8 |
| [22] | The time period ID from DE1156 of a matching SG6 RFF+Z47/Z48/Z49 (usage period of the data) must be entered |
| [23] | If the STS+E01++A05 (status of the response) is present in this SG4 |
| [24] | If the STS+E01++A25 (status of the response) is present in this SG4 |
| [25] | If the marketing type of the generating market location is assigned to the market premium |
| [27] | If the DE2380 of SG4 DTM+Z01 (notice period of the contract) contains a T or R in the fourth position |
| [28] | If in this SG4 IDE+24 the STS+E01++A04: E_0017 or A03: E_0052 (additional data record / supplemented market location) is not present |
| [29] | If in this SG4 IDE+24 the STS+E01++A06: E_0017 or A05: E_0052 (too many market locations included / removed market location) is not present |
| [30] | If a response to the activation is transmitted |
| [31] | If a correction is made |
| [32] | If more than one SG8 (reference to the location bundle structure) is present |
| [33] | If in a SG8 SEQ+Z79 a product code is named in PIA+5 (required product) DE7140 that is filled in the code list of configurations in chapter 6 "Products for the order placement / change of data" in the column "Code of the product property 9991000002272 („supplier“ (recipient of the remuneration for feed-in)). |
| [34] | If a response to the deactivation is transmitted |
| [35] | If the DE2380 of SG4 DTM+Z01 (notice period of the contract) contains T (date) in the fourth position |
| [36] | If in the same SG8 SEQ+Z79 a product code is named in the PIA+5 (required product) DE7140 that is filled with a code in the column "Code of the product property (value range)" in the code list of configurations in chapter 6.1 "Registration of an assignment of the LFN (UTILMD)". |
| [37] | If the registration/change is limited in time |
| [38] | Only the product property codes for the product code stated in the same SG8 SEQ+Z79 in PIA+5 (Required product) DE7140 are permitted that appear in the same row as the product code in chapter 6.1 "Registration of an assignment of the LFN (UTILMD)" of the code list of configurations and are listed in the column "Product property code (value range)". |
| [39] | If in the same SG8 SEQ+Z79 a product code is named in the PIA+5 (required product) DE7140 for which the condition possibly contained in the column "Value details for item" in the code list of configurations in chapter 6.1 "Registration of an assignment of the LFN (UTILMD)" is met |
| [40] | Only the value range is permitted that belongs to the product stated in the same SG8 SEQ+Z79 in PIA+5 (required product) DE7140 and that is stated in the code list of configurations in chapter 6.1 "Registration of an assignment of the LFN (UTILMD)" in the same row as the product code in the column "Value details for line item" |
| [41] | A product package ID from DE1050 of a SG8 SEQ+Z79 (component of a product package) must be stated |
| [42] | If more than one SG8 SEQ+ZH0 (prioritization of required product package) is present |
| [43] | If the STS+E01++A12 / A13 (status of the response) is present in this SG4 |
| [44] | The time period ID from DE1156 of a matching SG6 RFF+Z49/Z53 (usage period of the data: "valid data", "no data") from the request message from SG6 RFF+TN DE1154 ((reference transaction number (from request message)) must be entered |
| [45] | If in the same SG8 the SG10 CCI+Z01++Z82 (scope of use: ID of the metering location handled in the process) is present |
| [46] | If an ID has been assigned for the object |
| [47] | If SG10 CCI+15++Z21 (aggregated time series type) CAV+DBA/VZR/EGS/LGS/SLS/SES/TLS/TES/BIL/BIP/BIT/GAL/GAP/GAT/GEL/GEP/GET/SOL/SOP/SOT/WFL/WFP/WFT/WNL/WNP/WNT is present |
| [48] | If the STS+E01++A99 (status of the response: other) is present in this SG4 |
| [49] | If the STS+E01++E14 (status of the response: rejection other) is present in this SG4 |
| [50] | If no SG8 SEQ+ZE7 (informative data of the tranche) with the same time period ID in DE1050 references the same market location ID with the RFF+Z18 (market location) as this SG8 SEQ+Z98 (informative data of the market location) |
| [51] | If the market location ID in SG8 RFF+Z18 of the same SG8 SEQ+Z98 (informative data of the market location) with the same time period ID in DE1050 does not refer to a SG8 SEQ+Z78 (reference to the location bundle struc ture) in which the SG8 RFF+Z31 (reference to the location bundle struc ture) contains the code of the location bundle struc ture with the ID 9992 00000 001 8 (consumption without metering location (flat rate)) |
| [52] | If SG10 CCI+Z07++Z55/Z56 (profile type: other consuming market location / other generating market location) is present |
| [53] | If further specifications beyond CCI+Z07 (profile type) are possible |
| [54] | If SG8 SEQ+Z01 (data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present |
| [56] | If a response code from the consent cluster is present in DE9013 (status of the response) in the STS+E01 |
| [57] | If in the same SG8 the CCI+Z45++ZD9 (billing takes place) is present |
| [58] | If in this CCI the DE3055 with the code 293 is present |
| [60] | If BGM+Z90 (termination of the assignment to the location) present |
| [61] | If BGM+Z89 (assignment to the location) present |
| [62] | If more than one SG8 SEQ+Z45 (grid usage billing data of the market location), with the same time period ID in DE1050, with a group/article ID in the SG8 PIA+Z02 (group article ID / article ID) that begins with 1- 08-1/2/3/4/5, is present |
| [63] | If the STS+E01++A15 (status of the response) is present in this SG4 |
| [64] | If more than one SG8 SEQ+ZE1 (informative grid usage billing data of the market location) with a group/article ID in the SG8 PIA+Z02 (group article ID / article ID) that begins with 1-08-1/2/3/4/5, is present |
| [65] | If in the same SG8 SEQ+ZE1 (informative grid usage billing data of the market location) a group/article ID in the PIA+Z02 (group article ID / article ID), which begins with 1-08-1/2/3/4/5, is present |
| [66] | If SG8 SEQ+ZH0 (prioritization of required product package) present more than once |
| [67] | If the code 9991000002933 (designate dormant market location) is present in no SG8 SEQ+Z79 (component of a product package) CCI+Z66/CAV+ZH9 (product property/code of the product property). |
| [68] | If SG8 SEQ+ZH0 (prioritization of required product package) present more than twice |
| [69] | If SG8 SEQ+ZH0 (prioritization of required product package) present more than three times |
| [70] | If SG8 SEQ+ZH0 (prioritization of required product package) present five times |
| [71] | If a response to the assignment is transmitted |
| [72] | If a response to the termination of the assignment is transmitted |
| [73] | If in the same SG8 a code from the code list of the group article and article ID is present in the PIA DE7140 that is marked with X in the column UTILMD/price specification |
| [76] | If the aggregated time series is at balancing area level |
| [77] | If SG8 SEQ+Z03 (metering device data) CAV+Z30 (identification/number of the device) is not present |
| [78] | If SG4 STS+7++E02 (transaction reason: move-in to creation) is not present |
| [79] | If SG4 STS+7++Z33 (move-out due to decommissioning) is present |
| [80] | If in the same SG8 SEQ+Z61 (product data of the controllable resource) the PIA+5 (product data of the controllable resource) is not present |
| [81] | If in the same SG8 SEQ+Z61/ZB3/ZB4 (product data of the controllable resource) the SG10 CCI+11 (details on the product of the controllable resource) is not present |
| [82] | If, in the same SG8 (data of the technical equipment), the SG10 CCI+Z63 (information on technical equipment) CAV+ZH7 (technical equipment present) is present |
| [83] | If the STS+E01++A08/A16/A99 (status of the response) is present in this SG4 |
| [84] | If SG4 STS+E01++A57 (status of the response) is present |
| [85] | If the DE2380 of SG4 DTM+Z01 (notice period of the contract) contains M, Q, H or J in the fourth position |
| [87] | The first day of a month at 0:00 (according to German time) must be stated |
| [88] | Value must be identical to DE2380 from the SG4 DTM+157 (change as of) |
| [89] | If, in the SG8 SEQ+Z01 (data of the market location) with a time period ID in DE1050 identical to the one in this SG8, the SG10 CCI+++ZA6 (forecast basis of the market location: forecast based on profiles) CAV+E14 (TLP/TEP) is present |
| [90] | If SG10 CCI+++ZA6 (forecast basis of the market location: forecast based on profiles) present once with CAV+E14 (TLP/TEP) and once with CAV+E02 (SLP/SEP) in this SG8 |
| [91] | If SG10 CCI+++ZA6 (forecast basis of the market location: forecast on the basis of profiles) is not present once with CAV+E14 (TLP/TEP) and once with CAV+E02 (SLP/SEP) in this SG8 |
| [92] | If a value within the SG or segment is changed |
| [93] | Permitted codes from the PRICAT BGM+Z32 (price sheet for metering point operation) of the responsible MSB |
| [94] | If a segment is present within the SG |
| [95] | If in the same SG10 the CCI+Z17 (type of electricity consumption ) CAV+ZE5 (e-mobility) is present |
| [96] | If SG4 STS+7++xxx+ZAP (transaction reason supplement dormant market location) is present |
| [97] | If the code of the product property (value range) 9991000002420 (market premium) is present in DE7110 in a SG10 CAV+ZH9 |
| [98] | If MP-ID in SG2 NAD+MS (message sender) in the role NB |
| [99] | If MP-ID in SG2 NAD+MS (message sender) in the role ÜNB |
| [100] | If SG10 CAV+TLS/TES/BIT/GET/GAT/SOT/WNT/WFT/WAT present |
| [101] | If SG10 CCI+++ZA6 (forecast basis of the market location: forecast based on profiles) CAV+E14/Z36 (TLP/TEP/TEP with ref. measurement) present in this SG8 |
| [102] | If SG10 CCI+++ZA6 (forecast basis of the market location: forecast based on profiles) CAV+Z36 (TEP with ref. measurement) present in this SG8 |
| [103] | If SG9 QTY+265 (energy / power for day-parameter-dependent market location: estimated annual quantity total) present in this SG8 |
| [104] | If SG9 QTY+Z08 (energy / power for day-parameter-dependent market location: adjusted electrical energy according to Annex D) present in this SG8 |
| [105] | If SG9 QTY+Z10 (energy / power for day-parameter-dependent market location: power of the market location) present in this SG8 |
| [106] | If in this SG8 SEQ+Z01 SG10 CCI+++ZA6 (forecast basis of the market location: forecast based on profiles) CAV+E02 (SLP/SEP) is present |
| [107] | If in the same SG8 the SG10 CAV+SLS/SES/BIP/GEP/GAP/SOP/WNP/WFP/WAP is present |
| [108] | If a group/article ID beginning with 1- 08-1/2/3/4/5 is present in the PIA+Z02 (group article ID / article ID) in the same SG8 (grid usage billing data of the market location) |
| [110] | If SG10 CAV+LGS/EGS/BIL/GEL/GAL/SOL/WNL/WFL / WAL present |
| [113] | If this concerns a response to the order placement of a metering time period |
| [114] | If the SG10 CCI+E03 (voltage level of the market location) CAV E06 (low voltage) is present in this SG |
| [115] | If the SG10 CCI+E03 (voltage level of the market location) CAV E05 (medium voltage) is present in this SG |
| [116] | If the SG10 CCI+E03 (voltage level of the market location) CAV E04 (high voltage) is present in this SG |
| [117] | If the RFF+Z18 (market location) from this SG8 refers to the same SG5 LOC+Z16 (market location) as a RFF+Z18 (market location) from a SG8 SEQ+Z01 (data of the market location) in which the SG10 CCI+++ZA6 (forecast basis of the market location: forecast based on profiles) CAV+E14 (TLP/TEP) is present |
| [118] | If in this SG8 SEQ+Z98 SG10 CCI+++ZA6 (forecast basis of the market location: forecast based on profiles) CAV+E02 (SLP/SEP) is present |
| [119] | If CAV+E02 (SLP/SEP) is present in the SG8 SEQ+Z01/Z98 SG10 CCI+++ZA6 (forecast basis of the market location: forecast based on profiles) |
| [120] | If a declaration of assignment is required by NB |
| [121] | If the SG8 RFF+Z14 (reference to the smart meter gateway) is not present in the SEQ+Z03/ZF5 (metering device data) |
| [122] | If in this SG8 SEQ+Z98 SG10 CCI+++E03 (voltage level of the market location) CAV+E06 (low voltage) is present |
| [123] | If at least one further SG8 SEQ+Z20 (OBIS data of the metering device smart meter gateway) references the same identification/number of the device with the SG8 RFF+MG (device number of the meter) |
| [124] | If at least one further SG8 SEQ+Z20 (OBIS data of the metering device smart meter gateway) with the same time period ID from the DE1050 of this SG8 references the same identification/number of the device with the SG8 RFF+MG (device number of the meter) |
| [125] | If in the same SG8 SEQ+Z76/ZC5/ZC6 (metering point operation billing data of the market location) Z02 (group article ID / article ID) is present in DE4347 of the PIA |
| [126] | The value resulting from the number of repetitions of the SG6 RFF+Z49/Z53 (usage period of the data: valid data/no data) must be entered. This means: the first SG6 RFF+Z49/Z53 thus has the „1“, the second the „2“, the third the „3“, etc. |
| [127] | The value resulting from the number of repetitions of the SG6 RFF+Z48/Z55 (usage period of the data: expected data/no data expected) must be entered. This means: the first SG6 RFF+Z48/Z55 thus has the „1“, the second the „2“, the third the „3“, etc. |
| [128] | The value resulting from the number of repetitions of the SG6 RFF+Z47/Z54 (usage period of the data: data present in the system/no data present in the system) must be entered. This means: the first SG6 RFF+Z47/Z54 thus has the „1“, the second the „2“, the third the „3“, etc. |
| [129] | Within one SG4 IDE, all DE3225 of the SG5 LOC+Z16 (market location) must contain the identical value |
| [130] | If present at the metering location |
| [131] | If this DTM+Z25 (use of the data from) in SG6 RFF (usage peri od of the data) is marked with the time period ID "1" in DE1156, the date in this DE2380 must be the day immediately following DTM+137 DE2380 (message dat e) at 0:00, or a day earlier than that at 0:00 German time |
| [132] | If this DTM+Z25 (use of the data from) in SG6 RFF (usage perio d of the data) is marked with the time period ID "1" in DE1156, the date in this DE2380 must be the day immediately following DTM+137 DE2380 (message date) at 0:00 German time |
| [133] | If present at the transmitted market location / metering location |
| [134] | If this DTM+Z25 (use of data from) is not in the SG6 RFF+Z48/Z55 (usage period of the data: expected data/no data expected) with time period ID "1" in DE1156, the date must correspond to the DTM+Z26 (use of data until) of the SG6 RFF+Z48/Z55 (usage period of the data: expected data/no data expected) with the next lower time period ID in DE1156 |
| [135] | If this DTM+Z25 (use of the data from) is not in SG6 RFF+Z47/Z54 (usage perio d of the data: data present in the system/no data present in the system) with the time period ID "1" in DE1156, the date must correspond to the DTM+Z26 (use of the data until) of the SG6 RFF+Z47/Z54 (usage perio d of the data: data present in the system/no data present in the system) with the next lower time period ID in DE1156 |
| [136] | If SG10 CCI+++E13 (meter type) CAV+EHZ (electronic household meter) present in this SG8 |
| [137] | Not for creation |
| [138] | If Z35 (instalment payment) is present in DE6063 in the same QTY |
| [139] | If SG10 CAV+IVA (individual reconciliation) not present in this SG8 |
| [140] | If Z34/Z35 (surcharge/instalment payment) is present in DE6063 in the same QTY |
| [141] | If SG10 CAV+MIW/MPW/MBW present |
| [142] | If SG8 PIA+Z01+:Z04/Z05 (calculation of the daily mean temperature: daily mean temperature provided by the provider / equivalent daily mean temperature) is present |
| [143] | If STS+7++ZX3 (transaction reason: billing data BK billing consuming MaLo) present |
| [144] | If STS+7++ZAN (transaction reason: correction of billing data BK billing consuming MaLo) present |
| [145] | If STS+7++ZX2 (transaction reason: billing data BK billing generating MaLo) present |
| [146] | If STS+7++ZA0 (transaction reason: correction of billing data BK billing generating MaLo) present |
| [147] | If present in the request |
| [148] | If in this SG8 the article ID 1-02-0-017/1-02-0-018 is present in the SG8 PIA+Z02 (group article ID / article ID) |
| [149] | If two SG8 SEQ+Z45 (grid usage billing data of the market location), with the same time period ID in DE1050, with article ID in the SG8 PIA+Z02 (group article ID / article ID), one SG8 with 1- 02-0-017 and one with 1- 02-0-018, are present |
| [150] | If in this SG8 the article ID 1-02-0-002 is present in the SG8 PIA+Z02 (group article ID / article ID) |
| [151] | If a metering product from the code list of configurations in chapter 4.4 with the transmission channel "from the SMGW" was ordered with the order placement. This allows the recipient of the values to configure its firewall precisely |
| [152] | If FTX+Z28 (IP range of the sender) not present |
| [153] | If FTX+Z27 (IP address of the sender) not present |
| [156] | If SG4 FTX+Z17 (target address URI) is present |
| [157] | If SG4 STS+7++Z33+ZZB is not present |
| [158] | If in the same SG8 SEQ+Z57 (OBIS data of the grid location) the PIA+5 (OBIS data of the grid location) is not present |
| [159] | If in the same SG8 SEQ+Z57 (OBIS data of the grid location) the SG10 CCI+11 (OBIS data of the grid location) is not present |
| [161] | If SG4 STS+7++E03+ZW8 (transaction reason supplement case 1) is present |
| [162] | If SG4 STS+7++E03+ZW9 (transaction reason supplement case 2) is present |
| [163] | If SG4 STS+7++E03+ZX0 (transaction reason supplement case 3) is present |
| [164] | If SG4 STS+7++E03+ZX1 (transaction reason supplement case 4) is present |
| [165] | If known |
| [166] | If present |
| [167] | If SG5 LOC+Z21 (tranche) present |
| [168] | If in this SG8 the article ID 1-02-0-002/003/004 is present in the SG8 PIA+Z02 (group article ID / article ID) |
| [169] | If two SG8 SEQ+Z45 (grid usage billing data of the market location), with the same time period ID in DE1050, with article ID in the SG8 PIA+Z02 (group article ID / article ID), one SG8 with 1- 02-0-002 and one with 1- 02-0-003/004, are present |
| [170] | If the address of the market location is present |
| [172] | If Z37 (no surcharge or instalment payment) is present in DE6063 in the same QTY |
| [173] | If DE1156 (consecutive number of a location bundle in the business transaction) in the RFF+Z33 (reference to the object code in the location bundle structure) is not present in the same SG8 SEQ+Z58/ZC9/ZD0/ZD6 (assignment of location to the object code of the location bundle) |
| [174] | If DE1156 consecutive number of a location bundle in the business transaction) in the RFF+Z33 (reference to the object code in the location bundle structure) is present in the same SG8 SEQ+Z58/ZC9/ZD0/ZD6 (assignment of location to the object code of the location bundle) |
| [175] | If the object code in RFF+Z33 (reference to the object code in the location bundle struct ure) in DE1154 of the same SG8 SEQ+Z58 (assignment of location to the object code of the location bundle) is present in a further SG8 SEQ+Z58 with the same sequential number |
| [176] | If DE1153 with code Z34 upstream metering location is present in the same segment |
| [177] | If DE1153 with code Z35 upstream grid location is present in the same segment |
| [178] | If the LOC+Z18 (grid location) is present |
| [179] | If the object code in RFF+Z33 (reference to the object code in the location bundle struc ture) in DE1154 of the same SG8 SEQ+Z58/ZC9 / ZD0/ZD6 (assignment of location to the object code of the location bundle ) is present in a further SG8 SEQ+Z58/ZC9 / ZD0/ZD6 (assignment of location to the object code of the location bundle ) with an identical code in DE1229 |
| [180] | If Z46 (no instalment payment) is present in DE6063 in the same QTY |
| [181] | If the sender has established the data protec tion prerequisites for being allowed to provide the data |
| [184] | If in the same SG8 SEQ+Z18 (data of the metering location) a CCI+Z01++Z82 (scope of use: ID of the metering location handled in the process) is present |
| [190] | If in the same SG8 SEQ+Z60/ZG8/ZG9/ZE0 (product data of the grid location) PIA+5+999100000072 1:Z12 is present |
| [191] | If STS+E01 (status of the response of the list) is not present in the SG4 IDE+Z01 (identification of a list) |
| [192] | If SG4 STS+7++XXX+ZW4/ZAP (transaction reason / supplement: consuming market location / dormant market location) is present |
| [193] | If the SG10 CCI ZB5 (voltage level of the aggregated time series) CAV E06 (low voltage) is present in this SG |
| [194] | If the SG10 CCI ZB5 (voltage level of the aggregated time series) CAV E05 (medium voltage) is present in this SG |
| [195] | If the SG10 CCI ZB5 (voltage level of the aggregated time series) CAV E04 (high voltage) is present in this SG |
| [196] | If the object code in RFF+Z33 (reference to the object code in the location bundle struc ture) in DE1154 of the same SG8 SEQ+Z58/ZC9/ZD0 (assignment of location to the object code of the location bundle ) is present in a further SG8 SEQ+Z58/ZC9/ZD0 with the same sequential number in DE1156 of the SG8 RFF, the same time period ID in DE1050 and identical codes in DE1229 of the SG8 SEQ |
| [197] | If the RFF+Z18 (market location) from this SG8 refers to the same SG5 LOC+Z16 (market location) as a RFF+Z18 (market location) from a SG8 SEQ+Z01 (data of the market location) in which the SG10 CCI+++ZA6 (forecast basis of the market location: forecast based on profiles) CAV+E02 (SLP/SEP) is present |
| [198] | If SG4 STS+7++E03(transaction reason: switch) is present |
| [199] | If CAV+E02 (SLP/SEP) is present in the SG8 SEQ+Z01/SG10 CCI+++ZA6 (forecast basis of the market location: forecast based on profiles) with an identical time period ID in DE1050 |
| [201] | If the market location / tranche is not assigned to the same tuple of balancing group, time series type, voltage level and supplier for the entire balancing month |
| [202] | If SG8 SEQ+Z78 RFF+Z39 (no standardized location bundle structure present), with identical time period ID in DE1050 as in DE3224 of this segment |
| [203] | If STS+7++E06 / Z39 / ZC6 / ZC7/ZT6/ZT7 / Z02 / ZZD present |
| [204] | If RFF+Z14 (reference to the smart meter gateway) is not present in the SG8+SEQ+Z03/ZA3/ZA4 (metering device data) with the same time period ID in the SG8 SEQ DE1050 and with identical quality in DE1229 of the SG8 SEQ, for the device number of a meter named in this RFF DE1154 |
| [205] | If SG5 LOC+Z19 (controllable resource) is present |
| [206] | If SG4 STS+7++ZG5 (transaction reason: cancellation of the future assignment pursuant to § 38 EEG 2014 or § 21b para. 1 no. 2 EEG 2017) is not present |
| [209] | If code 303 is present in DE2379 in the same segment |
| [210] | If SG10 CCI+++ZA6 (forecast based on profiles) present in this SG8 |
| [212] | If NAD DE3124 is not present in the same SG12 |
| [213] | If SG12 NAD+Z09 (customer of the supplier) is present |
| [215] | If in the same SG8 (metering device data) SG10 CCI+++E13 CAV+MME (meter type: mME) is present |
| [216] | If CCI+++Z88 (grid usage) CAV+Z74:::Z08 (grid usage contract: direct contract between customer and NB) present |
| [217] | If SG6 RFF+Z49 (usage period of the data: "valid data") present |
| [219] | If SG12 NAD+Z65 (informative customer of the supplier) present |
| [220] | If SG8 SEQ+Z01/Z98 (data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present in this SG8 |
| [221] | If no SG8 SEQ+Z15 (data of the tranche) references the same market location ID with the RFF+Z18 (market location) as this SG8 SEQ+Z01 (data of the market location) |
| [223] | If the RFF+Z18 (market location) from this SG8 refers to the same SG5 LOC+Z16 (market location) as a RFF+Z18 (market location) from a SG8 SEQ+Z01 (data of the market location), and the SG10 CCI+Z30++Z06 (delivery direction: generation) is present there |
| [224] | If no SG8 SEQ+ZE7 (informative data of the tranche) references the same market location ID with the RFF+Z18 (market location) as this SG8 SEQ+Z98 (informative data of the market location) |
| [227] | If, in the SG8 SEQ+Z98 (data of the market location), the SG10 CCI+++ZA6 (forecast basis of the market location: forecast based on profiles) CAV+E14 (TLP/TEP) is present |
| [229] | If the object code in RFF+Z33 (reference to the object code in the location bundle struc ture) in DE1154 of the same SG8 SEQ+Z58/ZC9/ZD0/ZD6 (assignment of location to the object code of the location bundle ) is present in a further SG8 SEQ+Z58/ZC9/ZD0/ZD6 (assignment of location to the object code of the location bundle ) with an identical time period ID in DE1050 and identical codes in DE1229 of the SG8 SEQ |
| [232] | If SG10 CCI+++Z83 (metering classification of the market location) CAV+Z52 (iMS) is present |
| [233] | If MP-ID in SG2 NAD+MR (message recipient) in the role NB |
| [234] | If SG10 CCI+++Z83 (metering classification of the market location) CAV+Z53 (kME/mME) is present |
| [237] | If in the same SG8 a group article ID / article ID in DE7140 of the PIA+Z02 (group article ID / article ID) begins with 1-06 (corresponds to charges for metering point operation with kME) |
| [238] | If SG4 IDE+24 (transaction) is not present |
| [239] | If in the same SG10 the CCI+Z17 (type of electricity consumption ) is present in the CAV+Z65 (heat/cooling) |
| [240] | If SG8 SEQ+Z01 (data of the market location) CCI+Z22++Z91 (marketing type of the generating market location:: market premium) is present |
| [241] | If MP-ID in SG2 NAD+MR (message recipient) in the role MSB |
| [242] | If more than one SG8 (reference to the location bundle structure) with the same time period ID in DE1050 is present |
| [243] | If SG10 CCI+6++ZA8 (aggreg. resp. NB) present in this SG8 |
| [244] | If SG10 CCI+6++ZA9 (aggreg. resp. ÜNB) present in this SG8 |
| [248] | If the consuming market location was commissioned within the last three years and the energy of the market location is delivered via metering locations equipped with iMS |
| [249] | Within one SG4 IDE, all DE1131 of the SG4 STS+E01 (status of the response) must contain the identical value |
| [251] | If MP-ID in SG2 NAD+MS (message sender) in the role BIKO |
| [252] | If DE0068 is present |
| [253] | If SG4 STS+E01++ZC9 (rejection (no assignment possible)) is not present |
| [254] | The code "AUA" must be entered |
| [255] | If the market location participates in Redispatch 2.0 |
| [256] | If in the same SG8 SEQ (OBIS data of the metering device / smart meter gateway) the PIA+5+1-b?:1.8.e / 1-b?:2.8.e is present |
| [257] | If in the same SG8 SEQ (OBIS data of the market location) the PIA+5+1-b?:1.9.e is present |
| [258] | If in this SG8 SEQ+Z01 (data of the market location) SG10 CCI+Z30++Z07 (consumption) is present |
| [259] | If in this PIA the code in DE7140 contains 1- 01, 1-03, 1-05 |
| [261] | If in this PIA the code in DE7140 begins with 1- 07-1/2, 1-10-1/2/4/5/6/7/8/9, 1-11-1 |
| [262] | If the product is present at the market location |
| [263] | If SG8 SEQ+Z01 (data of the market location) SG10 CCI+Z30++Z07 (consumption) present |
| [265] | If, in the SG8 SEQ+Z01/Z98 (data of the market location), the SG10 CCI+++ZA6 (forecast basis of the market location: forecast based on profiles) CAV+Z36 (TEP w. reference measurement) is present |
| [266] | If, in the SG8 SEQ+Z01 (data of the market location) with a time period ID in the SG8 SEQ+Z01 DE1050 identical to the one in this SG8 SEQ, the SG10 CCI+++ZA6 (forecast basis of the market location: forecast based on profiles) CAV+Z36 (TEP w. reference measurement) is present |
| [267] | If SG8 SEQ+Z38 (reference profile data) not present |
| [268] | If an "X" is listed for the code in DE3207 in the column "PLZ present" of the "EDI@Energy code list of European country codes" |
| [269] | All OBIS codes in accordance with EDI@Energy code list of OBIS codes and media for the German energy market, chapter 3, that are required at the tranche must be stated |
| [270] | If in this PIA the code in DE7140 begins with 1- 02, 1-04, 1-06, 1-09 |
| [273] | If in the same SG8 SEQ+Z20 (OBIS data of the metering device / smart meter gateway) the PIA+5+1-b?:1.8.e / 1-b?:2.8.e / 1-b?:3.8.e / 1-b?:4.8.e / 1-b?:5.8.e / 1-b?:6.8.e / 1-b?:7.8.e / 1-b?:8.8.e / 1- b?:1.8.63 is present |
| [279] | If STS+7++xxx+ZW4 / ZAP (transaction reason supplement consuming market location / dormant market location) present |
| [280] | Only MP-ID from the electricity division |
| [282] | If in this PIA the code in DE7140 contains 1-01-6- 005, 1-01-9-001/002, 1-07-3- 001, 1- 08-1-001, 1-08-3-001, 1-08-4-001/002/003/004, 1- 10-3-001 |
| [284] | Permitted codes from the code list of the group article and article ID are marked with X in the UTILMD/code usage column |
| [285] | If in this PIA the code in DE7140 is specified with 1- 08-3-AGS |
| [286] | If in this PIA the code in DE7140 with 1- 08-1/2/4/5-AGS-KG |
| [287] | Permitted codes from the PRICAT BGM+Z70 (price sheet for grid usage) of the responsible NB |
| [288] | If in the same SG8 (OBIS data of the market location) the PIA+5+1-b?:2.9.e is present |
| [291] | If in the same SG8 (assignment of location to the object code of the location bundle ) the RFF+Z37 is present |
| [292] | Only the product codes are permitted that are marked with the corresponding check identifier of the use case in the column "Registration of an assignment of the LFN (UTILMD) " in chapter 6.1 "Registration of an assignment of the LFN (UTILMD)" of the code list of configurations. |
| [293] | If SG5 LOC+Z22 (dormant market location) present |
| [294] | If SG5 LOC+Z18 (grid location) is present |
| [295] | If SG5 LOC+Z15 (MaBiS metering point) is not present |
| [296] | If SG5 LOC+Z20 (technical resource) present |
| [297] | If more than one SG8 SEQ+Z02/ZE3 (OBIS data of the market location) with a OBIS code for energy quantity in PIA+5, with the same time period ID and identical code in DE1229 of the SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location), is present |
| [300] | If SG8 SEQ+Z15/ZE7 (data of the tranche) is not present |
| [301] | If BGM+E03 (change notification ) present |
| [302] | If SG8 SEQ+Z08 (profile set data) is not present |
| [303] | If SG8 SEQ+Z21 (profile data) not present |
| [304] | If SG8 SEQ+Z22 (data of the aggregated time series) present |
| [305] | If SG8 SEQ+Z24 (data of the transfer time series) present |
| [306] | If SG5 LOC+Z22 (dormant market location) present with the same time period ID in DE3224 as in this SG8 in DE1050 (reference to time period ID) of SEQ+Z58 |
| [307] | If SG5 LOC+Z22 (dormant market location) not present with the same time period ID in DE3224 as in this SG8 in DE1050 (reference to time period ID) of SEQ+Z58 |
| [309] | If SG5 LOC+Z22 (dormant market location) not present |
| [314] | All OBIS codes in accordance with the code list of OBIS codes and media, chapter 3, that are required at the market location must be stated. The minimum scope of the OBIS codes results from the metering product codes stated in chapter 5.1 of the document Code list of configurations |
| [315] | If BGM+Z88 (data clearing) present |
| [316] | If in the same SG8 the RFF+Z14 (smart meter gateway) is not present |
| [317] | The same value as in DE2380 of DTM+92 (contract start date) must be entered |
| [318] | The same value as in DE2380 of DTM+93 (contract end date) must be entered |
| [323] | All OBIS codes in accordance with EDI@Energy code list of OBIS codes and media for the German energy market, chapter 3., that are used at the metering device must be stated. The minimum scope of the OBIS codes results from the metering product codes stated in chapter 5.1 of the document "Code list of configurations" |
| [327] | If the time period ID in DE1050 of this SG8 SEQ, which is identical to the time period ID of a SG6 RFF+Z47/Z48/Z49 (usage period of the data) and in whose SG the SG6 DTM+Z25 (use of the data from) in DE2380 is ≥ 202212312300?+00 |
| [328] | If the market location is decommissioned |
| [329] | If in this SG4 IDE+24 the STS+E01++A03: E_0096 or A04:E_0097 (status of the response) is not present |
| [332] | If, in the SG8 SEQ+Z01 (data of the market location) with a time period ID in DE1050 identical to the one in this SG8, the SG10 CCI+6++ZA9 (aggreg. respons. ÜNB) is not present |
| [333] | If in this RFF "reference to the location bundle structure" the code Z31 "location bundle structure" is present in DE1153 |
| [334] | Only MP-ID from the gas division |
| [335] | If in this SG8 a time period ID is specified in DE1050 in the SEQ+Z58 (assignment of the location to the object code of the location bundle ) as in a SG8 SEQ+Z78 RFF+Z31 (reference to the location bundle structure) in DE1154 |
| [336] | If filled in the change notification |
| [337] | If SG10 CCI+++ZB4 (designation of the aggregated time series) CAV+Z95/Z96 is present |
| [338] | If CCI+++ZB4 (designation of the aggregated time series) CAV+Z95/Z96/Z97/Z99/ZA1/ZA3/ZA4/ZG7 present |
| [339] | If CCI+++ZB4 (designation of the aggregated time series) CAV+Z97/Z98/Z99/ZA0/ZA1/ZA2/ZA3/ZA6/ZG7 present |
| [340] | If CCI+++ZB4 (designation of the aggregated time series) CAV+Z95/Z97/Z98/Z99/ZA1/ZA2/ZA3/ZA4/ZA5/ZA6 present |
| [341] | If CCI+++ZB4 (designation of the aggregated time series) CAV+Z96/ZA0/ZG7 present |
| [342] | If an active MaBiS-ZP is present for the period under review |
| [344] | If the SG10 CCI+++ZB4 (designation of the aggregated time series) CAV+ZF1 (grid load time series (NGZ)) is present in this SG8 |
| [345] | If SG5 LOC+Z17 (metering location) is present |
| [346] | If SG10 CCI+++E13 (meter type) CAV+MME (mME) present in this SG8 |
| [347] | If SG5 LOC+Z16 (market location) is not present |
| [348] | If SG5 LOC+Z21 (tranche) not present |
| [349] | If SG5 LOC+Z17 (metering location) is not present |
| [350] | If SG8 SEQ+Z78/ZD5 RFF+Z31 (reference to the location bundle structure) present |
| [351] | If SG4 STS+E01++A04/A05 / A13 /A14 (status of the response) is present |
| [352] | If SG4 STS++A05/A06/A14 / A15 (status of the response) is present |
| [353] | Only codes from the „Code“ column of the code list of purposes of use (chapter 2) are permitted, provided that an „X“ is set in the same row both in the „Location/NeLo“ column and in the „Usable for market role/NB“ column and the statements in the „Explanation“ column match the OBIS code specified in DE7140 of the same PIA |
| [354] | Only codes from the „Code“ column of the code list of purposes of use (chapter 2) are permitted, provided that an „X“ is set in the same row both in the „Location/NeLo“ column and in the „Usable for market role/LF“ column and the statements in the „Explanation“ column match the OBIS code specified in DE7140 of the same PIA |
| [355] | If SG4 STS+E01++A45 (status of the response) is present |
| [356] | If SG4 STS+E01++A50 (status of the response) is present |
| [357] | If SG4 STS+E01++A03/A09/A12/A17 (status of the response) is present |
| [358] | If SG4 STS+E01++A06 (status of the response) is present |
| [359] | Only response codes from the rejection cluster are permitted |
| [360] | Only response codes from the consent cluster are permitted |
| [363] | If SG4 STS+E01++A50 (status of the response) is present |
| [365] | If in this SG4 IDE+24 the STS+E01++A04: E_0047/E_0014 or A03: E_0049/E_0004 (status of the response) is not present |
| [366] | Apart from code A30, all codes from EBD E_0624 in the rejection cluster are permitted |
| [367] | If SG4 STS+E01++A05/A14 (status of the response) is present |
| [368] | Apart from code A41, all codes from EBD E_0624 in the rejection cluster are permitted |
| [370] | If SG10 CAV+TLS/TES/BIT/GET/GAT/SOT/WNT/WFT/WAT |
| [371] | If SG8 SEQ+Z38 (reference profile data) not present |
| [372] | If SG10 CAV+TES/BIT/GET/GAT/SOT/WNT/WFT/WAT present |
| [373] | If a reference profile is present at the market location |
| [375] | For the ID in SG5 LOC+Z15 (MaBiS metering point) DE3225, if SG8+Z24 (data of the transfer time series) is not present |
| [376] | For the ID in SG5 LOC+Z15 (MaBiS metering point) DE3225, if SG8+Z22 (data of the aggregated time series) is not present |
| [377] | If SG10 CCI+15++Z21 (transfer time series type ) CAV+AUS is present |
| [378] | If SG10 CCI+15++Z21 (transfer time series type ) CAV+AUS is not present |
| [379] | If SG10 CCI+15++Z21 (transfer time series type ) CAV+code for EEG transfer time series (excluding AU1) is present |
| [380] | If SG10 CCI+15++Z21 (transfer time series type ) CAV+AUS/AU1 is present |
| [381] | Only codes from the „Code“ column of the code list of purposes of use (chapter 2) are permitted, provided that an „X“ is set in the same row both in the „Location/MaLo“ column and in the „Usable for market role/NB“ column and the statements in the „Explanation“ column match the OBIS code specified in DE7140 of the same PIA |
| [382] | Only codes from the „Code“ column of the code list of purposes of use (chapter 2) are permitted, provided that an „X“ is set in the same row both in the „Location/MaLo“ column and in the „Usable for market role/LF“ column and the statements in the „Explanation“ column match the OBIS code specified in DE7140 of the same PIA |
| [383] | Only codes from the „Code“ column of the code list of purposes of use (chapter 2) are permitted, provided that an „X“ is set in the same row both in the „Location/MaLo“ column and in the „Usable for market role/ÜNB“ column and the statements in the „Explanation“ column match the OBIS code specified in DE7140 of the same PIA |
| [384] | If in the same SG8 SG10 CCI+Z37++ZD1 (basis for forming the tranche size) (percentage) is present |
| [386] | If more than one SG8 SEQ+Z02/ZE3 (OBIS data of the market location) with a OBIS code for energy quantity in PIA+5 is present |
| [387] | If in the same SG8 (OBIS data of the market location) an OBIS code for energy quantity is present in the PIA+5 and, according to code list OBIS, this is a OBIS with an assigned metering time period (tariff: e = 1 .. 62) |
| [388] | Segment group must be specified at least once for each period ID from DE1156 of the SG6 RFF+Z49 (usage period of the data: "Valid data") if reactive energy or reactive power is to be recorded at the grid location in this time period. |
| [391] | If in the same SG8 SEQ+Z20 (OBIS data of the metering device / smart meter gateway) an OBIS code for meter reading is present in the PIA+5 and, according to code list OBIS, this is a OBIS with an assigned metering time period (tariff: e = 1 .. 62) |
| [392] | If the code in this PIA is specified in the format n1-n2- n1 |
| [393] | If the code in this PIA is specified in the format n1-n2- n1-n3 |
| [394] | If the code in this PIA is specified in the format n1-n2- n1-n8-n2 |
| [395] | If the code in this PIA is specified in the format n1-n2- n1-n8 |
| [396] | If in the same SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location) an OBIS code for active energy and 1/4 hour is present in the PIA+5 |
| [397] | If in this PIA the code in DE7140 begins with 1- 08-1/1-08-4 |
| [398] | If in this PIA the code in DE7140 begins with 1- 08-2/1-08-5 |
| [399] | If, in the SG8 SEQ+Z78 with a time period ID in DE1050 identical to the one in DE3224 of this segment, code Z31 (location bundle structure) is present in DE1153 of the RFF+Z31 (location bundle structure), and a code is present in DE1154 (ID of the location bundle structure) which is not the code 9992 00000 001 8. |
| [401] | If this DTM+Z25 (use of data from) is not in the SG6 RFF+Z49/Z53 (usage period of the data: valid data/no data) with time period ID "1" in DE1156, the date must correspond to the DTM+Z26 (use of data until) of the SG6 RFF+Z49/Z53 (usage period of the data: valid data/no data) with the next lower time period ID in DE1156 |
| [402] | If in the same SG8 (OBIS data of the metering device / smart meter gateway) an OBIS code of the value type "meter reading" is present in the PIA+5 |
| [403] | If not the same MP-ID is present in SG2 NAD+MS (message sender) and in the SG8 SEQ+Z01 (data of the market location) SG10 CCI+++ZB3 (assigned market partners) CAV+Z91 (metering point operator) |
| [404] | If not the same MP-ID is present in SG2 NAD+MR (message recipient) and in the SG8 SEQ+Z01/Z98 (data of the market location) SG10 CCI+++ZB3 (assigned market partners) CAV+Z91 (metering point operator) |
| [405] | If in the same SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location) an OBIS code for active energy and cumulative is present in the PIA+5 |
| [406] | If in the same SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location) an OBIS code for active energy and highest 1/4 hour in the month is present in the PIA+5 |
| [407] | If in the same SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location) an OBIS code for reactive energy is present in the PIA+5 |
| [408] | If a SG8 SEQ+Z02 (OBIS data of the market location), which references the same ID of a market location with the RFF+Z18 (reference to the ID of the market location) as the RFF+Z18 (reference to the ID of the market location) in this SG8, with a OBIS code for active energy and cumulative in PIA+5 is present |
| [409] | If no SG8 SEQ+Z02 (OBIS data of the market location), which references the same ID of a market location with the RFF+Z18 (reference to the ID of the market location) as the RFF+Z18 (reference to the ID of the market location) in this SG8, with a OBIS code for active energy and cumulative in PIA+5 is present |
| [410] | If a SG8 SEQ+Z02 (OBIS data of the market location), which references the same ID of a market location with the RFF+Z18 (reference to the ID of the market location) as the RFF+Z18 (reference to the ID of the market location) in this SG8, with a OBIS code for active energy and 1/4 hour in PIA+5 is present |
| [411] | If no SG8 SEQ+Z02 (OBIS data of the market location), which references the same ID of a market location with the RFF+Z18 (reference to the ID of the market location) as the RFF+Z18 (reference to the ID of the market location) in this SG8, with a OBIS code for active energy and 1/4 hour in PIA+5 is present |
| [412] | Only configuration product codes from the "EDI@Energy code list of configurations", chapter 4.2 Configuration products power curve definition, are permitted |
| [417] | If no metering time period is required for the required value |
| [419] | If in this data element no other package in this SG10 in the same SG8 SEQ leads to the possibility of specifying at least one other code |
| [420] | If the RFF+Z14 (smart meter gateway) is present in this SG8 |
| [421] | If the SG10 CCI+Z39 (assigned metering time period definition) is present in this SG8 |
| [422] | Only codes from the „Code“ column of the code list of purposes of use (chapter 2) are permitted, provided that an „X“ is set in the same row both in the „Location/Tranche“ column and in the „Usable for market role/NB“ column and the statements in the „Explanation“ column match the OBIS code specified in DE7140 of the same PIA |
| [423] | Only codes from the „Code“ column of the code list of purposes of use (chapter 2) are permitted, provided that an „X“ is set in the same row both in the „Location/Tranche“ column and in the „Usable for market role/LF“ column and the statements in the „Explanation“ column match the OBIS code specified in DE7140 of the same PIA |
| [424] | Only codes from the „Code“ column of the code list of purposes of use (chapter 2) are permitted, provided that an „X“ is set in the same row both in the „Location/Tranche“ column and in the „Usable for market role/ÜNB“ column and the statements in the „Explanation“ column match the OBIS code specified in DE7140 of the same PIA |
| [425] | Metering product code from chapter 2.1 "Standard metering products of the market location" of the code list of configurations |
| [426] | Metering product code from chapter 2.2 "Standard metering products of the tranche" of the code list of configurations |
| [427] | Metering product code from chapter 2.3 "Standard metering products of the metering location" of the code list of configurations |
| [428] | If in the same SG8 SEQ+Z27/ZE2 (required metering product of the market location) the PIA+5 DE7140 is present with a metering product from the code list of configurations chapter 2.1.1 standard metering product of the market location with the option of assigning a metering time period |
| [429] | If in the same SG8 SEQ+Z19/ZF4 (required metering product of the metering location) the PIA+5 DE7140 with a metering product from the code list of configurations chapter 2.3.1 standard metering product of the metering location with the option of assigning a |
| [430] | If another SG8 SEQ+Z27 (required metering product of the market location), which references the same ID of a market location with the RFF+Z18 (reference to the ID of the market location), with PIA+5+9991000000078:Z11 (for active energy load curve 1/4-hourly) is present |
| [431] | If no other SG8 SEQ+Z27 (Required metering product of the market location), which references the same ID of a market location with the RFF+Z18 (reference to the ID of the market location), with PIA+5+9991000000078:Z11 (active energy load curve 1/4-hourly) is present |
| [432] | If in the same SG8 SEQ+Z27 (required metering product of the market location), the PIA+5+9991000000078: Z11 (active energy load curve 1/4-hourly) is present |
| [433] | If no other SG8 SEQ+Z27 (Required metering product of the market location), which references the same ID of a market location with the RFF+Z18 (reference to the ID of the market location), with PIA+5 DE7140 with a metering product from the code list of configurations chapter 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present |
| [435] | If another SG8 SEQ+Z27 (required metering product of the market location), which references the same ID of a market location with the RFF+Z18 (reference to the ID of the market location), with PIA+5 DE7140 with a metering product from the code list of configurations chapter 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present |
| [436] | If in the same SG8 SEQ+Z27 (required metering product of the market location), the PIA+5+9991000000086:Z11 (active energy highest 1/4 hour in the month) is present |
| [437] | If the STS+E01++A04 / A23 (status of the response) is present in this SG4 |
| [438] | If code Z39 (code of the metering time period) is present in DE7059 in the same CCI |
| [440] | If code Z35 (upstream grid location) is present in DE1153 in the same RFF |
| [441] | If RFF+Z14 (reference to the smart meter gateway) is not present in the SG8+SEQ+Z03/ZF5 (metering device data) for the device number of a meter named in this RFF DE1154 |
| [442] | If code Z34 (upstream metering location) is present in DE1153 in the same RFF |
| [444] | If in the same SG8 (product data of the grid location) the PIA+5 (product data of the grid location) is not present |
| [445] | If in the same SG8 (product data of the grid location) the SG10 CCI+11 (details on the product of the grid location) is not present |
| [446] | If in the same SG8 the CCI+Z17 (type of electricity consumption ) is present |
| [447] | If in the same SG8 the CCI+Z50 (type of electricity generation ) is present |
| [448] | If in the same SG8 the CCI+Z56 (storage) is present |
| [449] | If in the same SG8 the SG10 CCI+6++ZA9 CAV=ZG3 (aggreg. resp. ÜNB and location in regular operation) is present |
| [450] | If code Z32 (grid location) is present in DE1153 in the same RFF |
| [451] | If code Z18 (market location) is present in DE1153 in the same RFF |
| [452] | If code Z19 (metering location) is present in DE1153 in the same RFF |
| [453] | If a metering product from the code list of configurations in chapter 4.4 with the trigger “When falling below/ exceeding the threshold” with independent change option was ordered with the order placement |
| [454] | The balancing start date must be earlier than the balancing end date in the SG8 “Data status of the ÜNB”, SG 9 energy quantity DZÜ share |
| [455] | The balancing end date must be later than the balancing start date in the SG8 “Data status of the ÜNB” , SG 9 energy quantity DZÜ share |
| [456] | If code Z37 (technical resource) is present in DE1153 in the same RFF |
| [457] | If the metering product 9991000001498 was ordered with the order placement |
| [458] | If the configuration product 9991000000739 was ordered with the order placement |
| [459] | If a metering product from the code list of configurations in chapter 4.4 with the transmission channel "CLS- direct from the SMGW" was ordered with the order placement |
| [460] | If a metering product from the code list of configurations in chapter 4.4 with the transmission channel "from the SMGW" was ordered with the order placement |
| [461] | If in the same SG10 the CCI (type and use of the technical resource) is present in the CAV+ZG8 (technical resource falls under § 14a EnWG) |
| [462] | If in the same SG10 the CCI+Z17 (type of electricity consumption ) is present in the CAV+ZH1 (commissioning of the TR before 2024) |
| [463] | If in the same SG10 the CCI+Z61++ZF9 (customer meets the requirement under EnFG) is present |
| [465] | If RFF+Z38 (reference to the controllable resource assigned to the technical resource) is present in the same SG8 (data of the technical resource) |
| [466] | If RFF+Z32 (reference to the grid location assigned to the technical resource) is present in the same SG8 (data of the technical resource) |
| [467] | If CAV+ZG8 (technical resource falls under § 14a EnWG) is present in the same SG8 (data of the technical resource) |
| [468] | If the SG10 CAV+ZH0 (commissioning of the TR after 2023) is present in the same SG8 (data of the technical resource) |
| [469] | If the SG10 CAV+ZH1 (commissioning of the TR before 2024) is present in the same SG8 (data of the technical resource) |
| [470] | If CAV+ZH5 (change to the § 14a EnWG model acc. to regulatory determination BK6-22- 300 has been carried out) is present in the same SG8 (data of the technical resource) |
| [471] | If a time period ID is named in DE1156 (time period ID) in the same SG6 RFF+Z49/Z53 (usage period of the data: valid data/no data) which is lower than in another SG6 RFF+Z49/Z53 (usage period of the data: valid data/no data) DE1156 (time period ID) |
| [472] | If a time period ID is named in DE1156 (time period ID) in the same SG6 RFF+Z48/Z55 (usage period of the data: expected data/no data expected) which is lower than in another SG6 RFF+Z48/Z55 (usage period of the data: expected data/no data expected) DE1156 (time period ID) |
| [473] | If a time period ID is named in DE1156 (time period ID) in the same SG6 RFF+Z47/Z54 (usage period of the data: data present in the system/no data present in the system) which is lower than in another SG6 RFF+Z47/Z54 (usage period of the data: data present in the system/no data present in the system) DE1156 (time period ID) |
| [474] | If SG4 STS+7++ZC8 (transaction reason "termination of the assignment") is present |
| [475] | If SG4 STS+7++ZH1 (transaction reason "cancellation of a future assignment due to decommissioning") is present |
| [476] | If SG4 STS+7++xxx+ZW0 (transaction reason supplement business transaction 1) is present |
| [477] | If SG4 STS+7++xxx+ZW1 (transaction reason supplement business transaction 2) is present |
| [478] | If SG4 STS+7++xxx+ZW2 (transaction reason supplement business transaction 3) is present |
| [479] | If SG4 STS+7++xxx+ZW3 (transaction reason supplement generating market location) is present |
| [480] | If SG4 STS+7++xxx+ZW4 (transaction reason supplement consuming market location) is present |
| [481] | If SG4 STS+7++xxx+ZW5 (transaction reason supplement tranche) is present |
| [483] | If SG4 STS+7++xxx+ZW7 (transaction reason supplement measured market location) is present |
| [484] | If SG4 STS+7++xxx+ZW8 (transaction reason supplement case 1) is present |
| [487] | If SG4 STS+7++xxx+ZX1 (transaction reason supplement case 4) is present |
| [490] | if the value in this DE, at position CCYYMMDDHHMM, is a point in time within the period stated in the table in chapter 3.5 “Overview of German statutory summer time (MESZ)” in the columns: “Summer time (MESZ) from” representation in UTC and “Summer time (MESZ) to” representation in UTC. |
| [491] | if the value in this DE, at position CCYYMMDDHHMM, is a point in time within the period stated in the table in chapter 3.6 “Overview of German statutory time (MEZ)” in the columns: “Winter time (MEZ) from” representation in UTC and “Winter time (MEZ) to” representation in UTC. |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [500] | Note: The code is to be selected according to the category of the notification to be canceled |
| [501] | Note: For support purposes, the data of the LFA must be specified |
| [502] | Note: The reference month of the DZR or BAS is specified |
| [503] | Note: Indication of BGM DE1004 from the ORDERS |
| [504] | Note: One transaction required per profile (including profile set where applicable) |
| [505] | Note: One transaction required per assigned ID and per EEG transfer time series |
| [506] | Note: For each code in LOC+Z16 (market location), the corresponding customer data of the LF should be specified, if known |
| [507] | Note: Start date originally confirmed by the NB |
| [508] | Note: Only kME can be billed via the NNE |
| [509] | Note: If it is a mME or iMS, RFF 1154 must always be stated with NEIN |
| [510] | Note: To be used for the deregistration of the ESV |
| [511] | Note: All balancing areas in which the profile is used must be specified |
| [512] | Note: The previous marketing type of the LFA at the generating market location must be specified for information |
| [513] | Note: The next possible date must be determined from the DTM+471 in the corresponding request |
| [515] | Note: To be specified for the ZP of the supplier aggregated time series |
| [516] | Note: The time of change must be specified on which the allocation end of the NBA and the allocation start of the NBN for a market location fall |
| [517] | Note: To be applied if a package ID has been assigned to a market location and is to be deleted again because it does not fall under the stated NB change |
| [518] | Note: All previous suppliers to which a deregistration request is sent must be specified |
| [519] | Note: If the code ZAP was present in the registration, it must also be used in the response |
| [520] | Note: If code ZAP is used, this is always a metered market location |
| [521] | Note: If the code ZAP is present in the second DE 9013 of STS+7 (transaction reason), the date stated here is to be understood as the allocation start when forming the "dormant MaLo. When integrating a MaLo as a dormant MaLo into an existing market location „Mapping of § 20 Abs. 1d EnWG or § 10c EEG“, this is the date from which the MaLo to be integrated was added. Nothing changes at the allocation start of the market location „Mapping of § 20 Abs. 1d EnWG or § 10c EEG“ |
| [522] | Note: The NBN must be specified |
| [523] | Note: At least once for each market location or tranche that was taken into account in the DZÜ / BG-CL / LF-SZR |
| [524] | Note: At least once for each market location or tranche for which the LF does not share the reported view of the NB |
| [527] | Note: All identifiers of the metering locations must be specified |
| [528] | Note: The date/dates from the request must be used |
| [529] | Note: For additional identifiers not standardized in the market, such as a grid operator project number |
| [530] | Note: All data existing at the location that are transmitted with this segment group and are valid on the date “change as of” must be specified. This may mean that segment groups or segments have to be repeated |
| [531] | Note: The year in which the next grid usage settlement takes place must be specified. This information must be given for the time period ID that contains SG6 RFF+Z49 (usage period of the data: valid data) and for which the next grid usage settlement takes place |
| [532] | Note: Critical data (in accordance with GPKE) |
| [533] | Note: The MP-ID of the supplier must be specified |
| [534] | Note: Due to the repeatability of the SG4 STS status of the response, up to eight usage periods can be specified |
| [555] | Note: The product package IDs from the registration that could not be implemented must be specified |
| [556] | Note: If no correspondence address of the end consumer/customer is available, the address of the market location must be transmitted |
| [557] | Note: If the responsible party has sent more than eight usage periods, eight arbitrary usage periods are answered |
| [558] | Note: This information can be exchanged voluntarily |
| [559] | Note: The correspondence address of the end consumer/customer is not used for identification |
| [560] | Note: This corresponds to business transaction A |
| [561] | Note: This corresponds to business transaction B |
| [562] | Note: For market locations that are balanced on the basis of values, the first day of the year is specified. |
| [563] | Note: For the ID of the supplier aggregated time series |
| [564] | Note: The IDE+Z01 (list) defines the business transaction. All listed IDE+24 are part of the business transaction |
| [565] | Note: The IDE+24 describes a component of a list if a IDE+Z01 is present. It does not describe the business transaction |
| [566] | Note: previous supplier |
| [567] | Note: New supplier |
| [568] | Note: Supplier of the supplier aggregate time series |
| [569] | Note: Third user |
| [570] | Note: Old grid operator |
| [571] | Note: All required products from the registration of the LF for the product package ID named in the same SG8 that could not be implemented must be specified |
| [572] | Note: Customer name from registration new supplier |
| [576] | Note: Master data of the previous metering point operator |
| [577] | Note: Filled with the start point in time originally confirmed by the NB |
| [578] | Note: This applies to the time period defined with Z53 (no data) |
| [579] | Note: Triggering market partner (LFN for STS+7++ZH0/ZG9, NB for STS+7++ZH1) |
| [580] | Note: Replacement supply exists only for - market locations at low voltage that are not household customers as defined by the EnWG and that are no longer subject to statutory substitute supply (three months) and - for market locations that are to be supplied at medium voltage/high voltage. The basis for a replacement supply is the bilateral agreement. |
| [581] | Note: The point in time must be specified at which the contract can still be terminated on the day the response is sent. |
| [586] | Note: The metering location address is assigned to the metering location that is marked in SG8 SEQ+Z18/ZF3 (data of the metering location) with CCI+Z01++Z82 (scope of use: ID of the metering location handled in the process) |
| [590] | Note: For receiving the control command |
| [594] | Note: The ZPB of the ZP of the NGZ and the ZPB of the NZR must be specified |
| [599] | Note: The name and address of the meter reading card recipient must be specified for the metering location that is identified in SG8 SEQ+Z18 (data of the metering location) with CCI+Z01++Z82 (scope of use: ID of the metering location handled in the process) |
| [601] | Note: The ID of the market location and all identifiers of the metering locations must be specified. Also, if present, the tranche(s) of the market location |
| [606] | Note: In this segment or SG, the data is to be stated from the perspective of the NB |
| [609] | Note: In this segment or SG, the data exchanged between NB, LF and ÜNB within market communication is to be stated from the perspective of the ÜNB |
| [611] | Note: If the company NB performs the tasks of the market role LF, the MP-ID of the company NB in the market role LF is to be stated |
| [614] | Note: Only the OBIS codes that are relevant for the balancing are transmitted |
| [617] | Note: Several transactions for one market location in the case of a change of balancing-relevant master data within the balancing month |
| [618] | Note: Previous date of the MSBA. If the MSBN wishes to use a different date, it communicates the new date by means of a master data change |
| [619] | Note: For the independent option to change the falling below / exceeding of the threshold value |
| [621] | Note: The MSB must be specified that is assigned to the location from the point in time named in DTM+76 (date of the planned start of supply). |
| [622] | Note: If the OBIS code is relevant for several market roles, the segment group must be repeated for each market role |
| [623] | Note: All identifiers of the metering locations that are required to determine the energy quantity of the market location named in the transaction must be specified |
| [630] | Note: If the list is rejected, no transaction is contained |
| [631] | Note: The list number from the supplier or balancing area clearing list must be used |
| [632] | Note: The list number from the supplier outage energy clearing list must be used |
| [637] | Note: In the case of a commitment request |
| [638] | Note: In the event of a request to take over the individual metering location by the gMSB |
| [639] | Note: If response to deactivation |
| [640] | Note: If response to activation |
| [641] | Note: If a single request exists |
| [642] | Note: If a subscription exists |
| [643] | Note: Subsequent grid operator |
| [645] | Note: The balancing group of the LF must be specified |
| [646] | Note: The RD balancing group of the ANB must be specified |
| [647] | Note: The RD balancing group of the anfNB must be specified |
| [648] | Note: If a product is no longer to exist as of the date "change as of", this is expressed by not stating PIA+5 |
| [651] | Note: The market locations for which the OBIS named here is required must be specified |
| [653] | Note: All grid locations, market locations, tranches and metering locations that are no longer assigned to the MSB as a result of the confirmation of the deregistration of the metering location handled in the process must be specified |
| [655] | Note: The list number from the DZÜ list must be used |
| [659] | Note: For tranches, only the reporting point of the tranche is to be specified |
| [660] | Note: The ID of the BK aggregated time series, aggregation level BG, must be specified |
| [662] | Note: The data NGZ and the data of the NZR must be specified |
| [663] | Note: The ID of the market location and the ZPB of the ZP of the NGZ must be specified |
| [664] | Note: The BG of the NB (LPB) must be specified |
| [665] | Note: If a meter is parameterized with a SMGW, no OBIS code numbers are stated for that meter. Only OBIS code numbers from the SMGW exist here |
| [667] | Note: For periods that were balanced but for which the ÜNB no longer has aggregation responsibility, a SG8 with SG8 - SG10 CCI+6=ZA8 or SG 10 CCI+6 = ZA9 CAV=ZG4 and SG8 - SG9 QTY+Z45 = 0 must be formed |
| [670] | Note: All grid locations that belong to the same location bundle must be specified |
| [671] | Note: All market locations that belong to the same location bundle must be specified |
| [672] | Note: All technical resources that belong to the same location bundle must be specified |
| [673] | Note: All controllable resources that belong to the same location bundle must be specified |
| [674] | Note: All tranches that belong to the same location bundle must be specified |
| [675] | Note: All metering locations that belong to the location bundle must be specified |
| [677] | Note: All grid locations that currently and / or in future belong to the same location bundle must be specified |
| [678] | Note: All market locations that currently and / or in future belong to the same location bundle must be specified |
| [679] | Note: All technical resources that currently and / or in future belong to the same location bundle must be specified |
| [680] | Note: All controllable resources that currently and / or in future belong to the same location bundle must be specified |
| [681] | Note: Transitional supply exists only for market locations that fall under § 38a EnWG. The basis is a bilateral agreement |
| [682] | Note: All metering locations that currently and / or in future belong to the same location bundle must be specified |
| [683] | Note: All IDs of the grid locations that are currently and / or in future upstream of the market location specified in SG5 LOC+Z16 must be specified |
| [684] | Note: All IDs of the technical resources that currently and / or in future belong to the market location specified in LOC+Z16/Z22 must be specified |
| [685] | Note: All IDs of the controllable resources that are currently and / or in future assigned to the technical resources specified in LOC+Z20 must be specified. |
| [686] | Note: To be used for the deregistration of the transitional supply. |
| [687] | Note: All metering locations that are currently and / or in future required for the energy quantity determination of the market location specified in LOC+Z16/Z22 must be specified |
| [688] | Note: All IDs of the grid locations that are upstream of the market location specified in LOC+Z16 must be specified |
| [689] | Note: All IDs of the technical resources that belong to the market location specified in LOC+Z16 must be specified |
| [690] | Note: All IDs of the controllable resources that are assigned to the technical resources specified in LOC+Z20 must be specified |
| [693] | Note: The data NGZ must be specified |
| [694] | Note: If an ID is assigned to a technical resource in a market location, IDs must be assigned to all further technical resources in that market location, where applicable. Background: MSB and LF need a complete overview of the type and use of the technical resources in a market location for plausibility checking, substitute value determination, product selection and forecast |
| [695] | Note: Use if the role LF is assigned to a company NB |
| [696] | Note: Use only if the role LF is not assigned to a company NB |
| [698] | Note: For a generating market location, an ID of the technical resources must be assigned for each technical resource. This is necessary in order to make the rated power of the technical resource known, because the POG of the MSB of a generating market location is determined on the basis of this information |
| [699] | Note: The ID of the controllable resource via which the technical resource is controlled must be specified |
| [700] | Note: The ID of the grid location via which the technical resource is controlled must be specified |
| [701] | Note: The Malo ID of the tranche to which the technical resource is assigned must be specified |
| [704] | Note: Segment is to be used if it was present in the request |
| [705] | Note: If the action of a sequence diagram "Response message on change" is carried out |
| [706] | Note: If the action of a sequence diagram "Order placement of a change of master data..." is carried out with the aim of performing a data clearing |
| [707] | Note: for further details see the chapter "SG6 Usage period of the data" |
| [708] | Note: If the action "Announcement of the assignment of the E/G to the market location" is carried out |
| [709] | Note: If the action "Assignment of the E/G to the market location due to a missing response" is carried out |
| [710] | Note: If the action "Announcement of the assignment of the LFN to the market location or tranche" is carried out |
| [711] | Note: If the action "Assignment of the LFN to the market location or tranche due to a missing response" is carried out |
| [712] | Note: If the action "Announcement of the termination of the assignment of the LF to the market location or tranche" is carried out |
| [713] | Note: If the action "Termination of the assignment of the LF to the market location or tranche due to a missing response" is carried out |
| [714] | Note: In the case of an area takeover during the year, the previous NB may be named here to show that the group article ID or article ID named in PIA+5 of this SG8 refers to the prices of the previous NB. If this is not the case, the own MP-ID is entered |
| [715] | Note: This transaction reason may only be applied for the affected location if a request Abr.-Daten BK-Abr. into the past was previously made by the LF or a correction was previously agreed bilaterally with the LF (this also includes a retroactive E/G confirmed by the LF)) |
| [716] | Note: If the action of a sequence diagram "Response message on billing data" is carried out |
| [717] | Note: If the action of the sequence diagram "Order placement of a change of billing data" is carried out with the aim of performing a data clearing |
| [718] | Note: All tranches of the market location named in SG5 LOC+Z16 (market location) that exist for the time periods named in SG6 (usage period of the data) must be specified |
| [719] | Note: This transaction reason may only be applied for the affected location if the LF responds to a request with this transaction reason or starts a request Abr.-Daten BK-Abr. into the past in order to request a bilateral correction from the NB |
| [902] | Format: Possible value: ≥ 0 |
| [910] | Format: Possible value: < 0 or ≥ 0 |
| [914] | Format: Possible value: > 0 |
| [922] | Format: TR-ID |
| [926] | Format: Possible value: 0 |
| [930] | Format: max. 2 decimal places |
| [931] | Format: ZZZ = +00 |
| [932] | Format: HHMM = 2200 |
| [933] | Format: HHMM = 2300 |
| [937] | Format: no decimal places |
| [938] | Format: Possible value: <= 10 |
| [942] | Format: n1- n2-n1-n3 |
| [943] | Format: n1- n2-n1 |
| [946] | Format: max. 11 decimal places |
| [948] | Format: n1-n2-n1-n8- n2 |
| [950] | Format: market location ID |
| [951] | Format: Metering point identifier |
| [952] | Format: device number according to DIN 43863-5 |
| [955] | Format: Possible value: < 100 |
| [957] | Format: n1- n2-n1-n8 |
| [960] | Format: Grid location ID |
| [961] | Format: SR-ID |
| [967] | Format: Certificate body in accordance with X509.1, BSI TR-03109-4 |
| [2000] | The segment group must be specified exactly once per SG5 LOC+Z16 (market location) |
| [2001] | Segment group must be specified at least twice per SG4 IDE+24 (transaction) |
| [2002] | To be given exactly once for each product package ID in SG8 SEQ+Z79 (component of a product package) DE1050 |
| [2003] | Once for each dormant market location that is subordinate to the market location "customer installation" from the SG5 LOC+Z16 (market location) as of the point in time from the SG4 DTM+92 (start on) |
| [2004] | Segment group must be specified exactly once for each time period ID from DE1156 of the SG6 RFF+Z49 (usage period of the data: "Valid data") |
| [2005] | Segment group must be specified at least once for each period ID from DE1156 of the SG6 RFF+Z49 (usage period of the data: "Valid data") |
| [2006] | Segment group must be specified exactly once for each SG8 SEQ+Z01 (data of the market location) for which condition [199] is fulfilled at the segment group. The same time period ID must be specified in the following SEQ DE1050 |
| [2007] | Segment group must be specified exactly once for each SG8 SEQ+Z01 (data of the market location) for which the conditions [199] are fulfilled at the segment group. The same time period ID must be specified in the following SEQ DE1050 |
| [2008] | Segment group must be specified exactly once for each SG8 SEQ+Z01 (data of the market location) for which condition [89] is fulfilled at the segment group. The same time period ID must be specified in the following SEQ DE1050 |
| [2009] | Segment group must be specified exactly once for each SG8 SEQ+Z01 (data of the market location) for which the conditions [89] are fulfilled at the segment group. The same time period ID must be specified in the following SEQ DE1050 |
| [2010] | Segment group must be specified exactly once for each SG8 SEQ+Z01 (data of the market location) for which the conditions [266] ∧ [479] are fulfilled at the segment group. The same time period ID must be specified in the following SEQ DE1050 |
| [2011] | Segment group must be specified exactly once for each time period ID from DE1156 of the SG6 RFF+Z49 / Z53 (usage period of the data: "Valid data" / "No data") from the request message from SG6 RFF+TN DE1154 (reference transaction number (from request message)) |
| [2012] | Segment group must be specified exactly once to state the informative data of the market location |
| [2013] | To be specified at least once if no SG6 RFF+Z54 (usage period of the data: no data available in the system) is present |
| [2014] | To be specified at least once if no SG6 RFF+Z47 (usage period of the data: data available in the system) is present |
| [2015] | Once for each dormant market location that is subordinate to the market location "customer installation" from the SG5 LOC+Z16 (market location) |
| [2016] | Segment group must be specified at least once for each period ID from DE1156 of the SG6 RFF+Z49 / Z53 (usage period of the data: "Valid data" / "No data") from the request message from SG6 RFF+TN DE1154 (reference transaction number (from request message)) |
| [2017] | The segment group must be specified exactly once per SG5 LOC+Z17 (metering location) |
| [2018] | Segment group must be specified exactly once for each SG8 SEQ+Z01 (data of the market location) for which the conditions [266] are fulfilled at the segment group. The same time period ID must be specified in the following SEQ DE1050 |
| [2060] | If SG10 CAV+NZR, the segment group must be specified exactly twice per IDE+24 |
| [2061] | Segment or segment group must be specified exactly once per SG4 IDE (transaction) |
| [2071] | For the ID of the supplier aggregated TS, once per SG4 IDE+24 (transaction) |
| [2073] | For the ID of the balancing group aggregated TS, once per SG4 IDE+24 (transaction) |
| [2075] | For the ID of the time series (not for EEG- EUZ and EUZ of the AAÜZ) in the clearing list, once per SG4 IDE+24 (transaction) |
| [2080] | Segment group must be specified max. twice per SG4 IDE+24 (transaction) |
| [2095] | The segment group must be specified exactly once per SG5 LOC+Z15 (MaBiS metering point) |
| [2096] | Segment group must be specified exactly twice per SG4 IDE |
| [2119] | The segment group must be specified exactly once per SG8 SEQ+Z13/ZG0 (smart meter gateway) |
| [2121] | Segment group must be specified exactly once per SG8 SEQ+Z01/Z80/Z81 (data of the market location/expected data of the market location/data of the market location present in the system) |
| [2140] | For the ID of the supplier aggregated TS, once per SG4 IDE+Z01 (list) |
| [2182] | Segment group must be specified exactly once per SG8 SEQ+Z01/Z80/Z81/Z98 (data of the market location/expected data of the market location/data of the market location present in the system) |
| [2183] | Segment group must be specified exactly twice per SG8 SEQ+Z01/Z80/Z81/Z98 (data of the market location/expected data of the market location/data of the market location present in the system) |
| [2207] | For the ID of the supplier outage energy aggregated time series, once per SG4 IDE+Z01 (list) |
| [2225] | Once for each market location or tranche for which the LF does not share the reported view of the NB |
| [2236] | Code once per SG4 IDE+24 (transaction) |
| [2252] | Once for each market location or tranche that was taken into account in the supplier outage energy aggregated time series |
| [2261] | To be given at least once for each ID in SG5 LOC+Z21 (tranche) DE3225 |
| [2284] | To be given exactly once for each metering location ID in SG5 LOC+Z17 (metering location) DE3225 |
| [2286] | To be given at least once for each SEQ+ZF3 (data of the metering location) |
| [2287] | To be given at least once for each SEQ+Z03/ZF5 (metering device data) |
| [2288] | Once for each time series that was taken into account in the DZR |
| [2307] | To be given exactly once for each ID in SG5 LOC+Z21 (tranche) DE3225 |
| [2308] | To be given at least once for each ID in SG5 LOC+Z16 (market location) DE3225 |
| [2309] | To be given at least once for each ID in SG5 LOC+Z17 (metering location) DE3225 |
| [2310] | To be given exactly once for each ID in SG5 LOC+Z16 (market location) DE3225 |
| [2311] | To be given at least once for each ID in SG5 LOC+Z21 (tranche) DE3225 |
| [2312] | If the object code "9992000001256" (grid location) is not present in DE1154 of the same RFF+Z33, the RFF+Z33 must be specified exactly once in the same SG8 SEQ+Z58/ZC9/ZD0/ZD6 (assignment of location to the object code of the location bundle ) |
| [2313] | To be specified exactly once per SG8 SEQ+Z58/ZC9/ZD0/ZD6 (assignment of the location to the object code of the location bundle ) |
| [2317] | If in the same SG8 SEQ+Z04/ZF7 (transformer data) the SG10 CCI+++Z25 (transformer) CAV+MIW/MPW/MUW is present, the segment must be specified at least twice |
| [2318] | If in the same SG8 SEQ+Z04/ZF7 (transformer data) the SG10 CCI+++Z25 (transformer) CAV+MBW (block current transformer ) is present, the segment must be specified exactly once |
| [2344] | Once for each market location or tranche that was taken into account in the DZÜ / BG-CL / LF-SZR |
| [2350] | For each SMGW named in SEQ+Z13/ZG0 (smart meter gateway) SG10 CCI+++Z75 CAV+Z30 (device number), at least once per SEQ+Z03/ZF5 (metering device data) that references the SMGW with SG8 RFF+Z14 (reference to the smart meter gateway) |
| [2351] | Once per ZP of a BK-SZR in which the market location was included in the calculation of the billed aggregated time series |
| [2352] | Once per ZP of a BG-SZR in which the market location was included in the calculation of the billed aggregated time series |
| [2356] | The segment group must be specified exactly once per SG5 LOC+Z18 (grid location) |
| [2357] | The segment group must be specified exactly once per SG5 LOC+Z20 (technical resource) |
| [2358] | The segment group must be specified exactly once per SG5 LOC+Z19 (controllable resource) |
| [2359] | To be given at least once for each ID in SG5 LOC+Z16 / Z17 / Z20 (market location / metering location / technical resource) DE3225 |
| [2360] | To be given at least once for each ID in SG5 LOC+Z18 (grid location) DE3225 |
| [2361] | To be given at least once for each ID in SG5 LOC+Z17 / Z20 / Z22 (metering location / technical resource / dormant market location) DE3225 |
UB conditions
UB conditions combine several markers into a single expression. In the handbook rows they appear like a condition, but they resolve into the markers they contain.
| Marker | Printout |
|---|---|
| [UB1] | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |
Condition packages
Condition packages bundle prerequisites.
| Package | Prerequisites | Conditions |
|---|---|---|
| [10P] | [66] | [66] If SG8 SEQ+ ZH0 (Prioritization required product package) more than once present |
| [11P] | [68] | [68] If SG8 SEQ+ ZH0 (Prioritization required product package) more than twice present |
| [12P] | [69] | [69] If SG8 SEQ+ ZH0 (Prioritization required product package) more than three times present |
| [13P] | [70] | [70] If SG8 SEQ+ ZH0 (Prioritization required product package) five times present |
| [14P] | ( [243] ⊻ [244]) ∧ [479] | [243] If SG10 CCI+6++ZA8 (Aggr. resp. NB) in this SG8 present [244] If SG10 CCI+6++ZA9 (Aggr. resp. ÜNB) in this SG8 present [479] If SG4 STS+7++xxx+ZW3 (Transaction reason supplement generating market location) present |
| [15P] | [481] | [481] If SG4 STS+7++xxx+ZW5 (Transaction reason supplement Tranche) present |
| [16P] | [243] ∧ [479] | [243] If SG10 CCI+6++ZA8 (Aggr. resp. NB) in this SG8 present [479] If SG4 STS+7++xxx+ZW3 (Transaction reason supplement generating market location) present |
| [17P] | [79] | [79] If SG4 STS+7++Z33 (move-out due to decommissioning) present |
| [18P] | [480] | [480] If SG4 STS+7++xxx+ZW4 (Transaction reason supplement consuming market location) present |
| [19P] | [20] ∧ [ 428 ] ∧ [4 30 ] | [20] If in the SG8 SEQ+Z01 (data of the market location) with the same ID in SG8 RFF+Z18 (reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) is present [ 428 ] If in the same SG8 SEQ+Z27 / ZE2 (Required metering product of the market location) the PIA+5 DE7140 with a metering product from the code list of configurations chapter 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present [4 30 ] If another SG8 SEQ+Z27 (Required metering product of the market location), which with the RFF+Z18 (reference to the ID of the market location) references the same ID of a market location, with PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present |
| [1P] | -- | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
| [20P] | [20] ∧ [ 428 ] ∧ [4 31 ] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [ 428 ] If in the same SG8 SEQ+Z27 / ZE2 (Required metering product of the market location) the PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present [4 31 ] If no other SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present |
| [21P] | [20] ∧ [ 432 ] ∧ [ 435 ] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [ 432 ] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [ 435 ] If another SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present |
| [22P] | [20] ∧ [ 432 ] ∧ [4 33 ] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [ 432 ] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [4 33 ] If no other SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present |
| [23P] | [54] ∧ [ 432 ] ∧ [ 435 ] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [ 432 ] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [ 435 ] If another SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present |
| [24P] | [54] ∧ [ 432 ] ∧ [4 33 ] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [ 432 ] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [4 33 ] If no other SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present |
| [25P] | [54] ∧ [ 428 ] ∧ [4 30 ] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [ 428 ] If in the same SG8 SEQ+Z27 / ZE2 (Required metering product of the market location) the PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present [4 30 ] If another SG8 SEQ+Z27 (Required metering product the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5+ 9991000000078 :Z11 ( for active energy load curve 1/4-hourly) is present |
| [26P] | [20] ∧ [ 430 ] ∧ [4 36 ] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [4 30 ] If another SG8 SEQ+Z27 (Required metering product the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5+ 9991000000078 :Z11 ( for active energy load curve 1/4-hourly) is present [436] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000086 :Z11 (active energy highest 1/4 hour in the month) is present |
| [27P] | [54] ∧ [4 2 8] ∧ [4 31 ] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [ 428 ] If in the same SG8 SEQ+Z27 / ZE2 (Required metering product of the market location) the PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present [4 31 ] If no other SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present |
| [28P] | [407] | [407] If in the same SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location) a OBIS code for reactive energy in the PIA+5 present |
| [29P] | [20] ∧ [405] ∧ [410] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [405] If in the same SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location) a OBIS code for active energy and cumulative in the PIA+5 present [410] If a SG8 SEQ+Z02 (OBIS data of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location as the RFF+Z18 (Reference to the ID of the market location) in this SG8, with a OBIS code for active energy and 1/4 hour in the PIA+5 present |
| [2P] | [301] ⊻ [315] | [301] If BGM+E03 (change notification) present [315] If BGM+Z88 (data clearing) present |
| [30P] | [20] ∧ [405] ∧ [411] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [405] If in the same SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location) a OBIS code for active energy and cumulative in the PIA+5 present [411] If no SG8 SEQ+Z02 (OBIS data of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location as the RFF+Z18 (Reference to the ID of the market location) in this SG8, with a OBIS code for active energy and 1/4 hour in the PIA+5 present |
| [31P] | [20] ∧ [396] ∧ [408] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [396] If in the same SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location) a OBIS code for active energy and 1/4 hour in the PIA+5 present [408] If a SG8 SEQ+Z02 (OBIS data of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location as the RFF+Z18 (Reference to the ID of the market location) in this SG8, with a OBIS code for active energy and cumulative in the PIA+5 present |
| [32P] | [20] ∧ [396] ∧ [409] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [396] If in the same SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location) a OBIS code for active energy and 1/4 hour in the PIA+5 present [409] If no SG8 SEQ+Z02 (OBIS data of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location as the RFF+Z18 (Reference to the ID of the market location) in this SG8, with a OBIS code for active energy and cumulative in the PIA+5 present |
| [33P] | [54] ∧ [396] ∧ [408] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [396] If in the same SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location) a OBIS code for active energy and 1/4 hour in the PIA+5 present [408] If a SG8 SEQ+Z02 (OBIS data of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location as the RFF+Z18 (Reference to the ID of the market location) in this SG8, with a OBIS code for active energy and cumulative in the PIA+5 present |
| [34P] | [54] ∧ [396] ∧ [409] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [396] If in the same SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location) a OBIS code for active energy and 1/4 hour in the PIA+5 present [409] If no SG8 SEQ+Z02 (OBIS data of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location as the RFF+Z18 (Reference to the ID of the market location) in this SG8, with a OBIS code for active energy and cumulative in the PIA+5 present |
| [35P] | [54] ∧ [405] ∧ [410] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [405] If in the same SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location) a OBIS code for active energy and cumulative in the PIA+5 present [410] If a SG8 SEQ+Z02 (OBIS data of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location as the RFF+Z18 (Reference to the ID of the market location) in this SG8, with a OBIS code for active energy and 1/4 hour in the PIA+5 present |
| [36P] | [20] ∧ [406 ] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [406] If in the same SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location) a OBIS code for active energy and highest 1/4 hour in the month in the PIA+5 present |
| [37P] | [54] ∧ [405] ∧ [411] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [405] If in the same SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location) a OBIS code for active energy and cumulative in the PIA+5 present [411] If no SG8 SEQ+Z02 (OBIS data of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location as the RFF+Z18 (Reference to the ID of the market location) in this SG8, with a OBIS code for active energy and 1/4 hour in the PIA+5 present |
| [38P] | [419] | [419] If no other package in this SG10 in the same SG8 SEQ leads to the possibility of specifying at least one other code in this data element |
| [3P] | [315] | [315] If BGM+Z88 (data clearing) present |
| [4P] | [315] ∧ [20 14 ] | [315] If BGM+Z88 (data clearing) present [20 14 ] To be specified at least once , if no SG6 RFF+Z47 (Usage period of the data: data present in the system) present |
| [5P] | [315] ∧ [2013] | [315] If BGM+Z88 (data clearing) present [20 13 ] To be specified at least once , if no SG6 RFF+Z54 (Usage period of the data: no data present in the system) present |
| [6P] | [ 243 ] | [243] If SG10 CCI+6++ZA8 (Aggr. resp. NB) in this SG8 present |
| [7P] | [244] | [244] If SG10 CCI+6++ZA9 (Aggr. resp. ÜNB) in this SG8 present |
| [8P] | [517] | [517] Note: To be used if a package ID has been assigned to a market location and is to be deleted again because it does not fall under the stated NB change |
| [9P] | [37] | [37] If registration/ change limited in time |
Notes on this page
This page carries the free text of every condition that the application handbook of message type UTILMDS references in this format version. A row of the handbook writes Muss [704]; what [704] requires is here.
The list applies to the message type, not to a single check identifier. This is not a simplification but the form of the source: the condition list is present identically in every handbook file of the format.
Why no assignment to individual check identifiers is given here
The intermediate format from which this documentation reads the handbook rows assigns conditions to a column — and this assignment is shifted against the original. Measured on 05.09.2026 against UTILMD electricity: the handbook lists STS DE9013 as X [360] (approval codes only) for check identifier 55017 and X [359] (rejection codes only) for 55018; the intermediate format puts [360] on 55016 and [359] on 55017 and 55018. The same applies to FTX Muss [83]: at 55018 in the handbook, at 55017 in the intermediate format.
Independently confirmed by the change lists of the source: change IDs 25242, 25821, 25822, 25445 and 25243 explicitly locate [83], [351] and [352] in „Use case 55018 Rejection of contract termination“. No entry assigns them to 55016 or 55017.
That is why the text of every condition is given here and nowhere the claim as to which condition applies to which check identifier. Anyone who needs that looks it up in the original application handbook.
1 condition does not appear in every handbook file
The list of conditions is meant to apply across the whole format, but it does not everywhere: the following markers occur in fewer than all 189 files of this format. They are given here nonetheless — leaving out a condition because one file does not carry it would mean letting a reference point into the void again.
[UB1]
As measured on 05.09.2026, no ahb_expression in this source points to a package marker — the condition packages are listed on this page because the source carries them, not because a handbook line refers to them.