LF (54)
E_0100 — Check profiles or profile sets
Check profiles or profile sets
| Attribute | Value |
|---|---|
| Designation | E_0100 check profiles or profile sets |
| Market role | LF |
| Regulatory determination / chapter | MaBiS |
| Section | 7.11.1: AD: Transmission of standardized profiles and profile sets from NB to LF |
| Check identifiers | Response: 17211 |
| EBD version | 4.2 |
| As at | 2026-06-23 |
Decision tree
| Step | Check | Result | Code | Note |
|---|---|---|---|---|
| 1 | Does the received profile or profile set belong to a previously subscribed profile group from the list of profile definitions? | no | A01 | Profile or profile set does not belong to a previously subscribed profile group |
| — | — | yes | → Step 2 | — |
| 2 | Was a profile set received? | no | → Step 3 | Note: A profile was received. |
| — | — | yes | → Step 4 | — |
| 3 | Is the transmitted version of the profile for the transmitted time period higher than the highest version of the profile processed so far for the same time period? | no | A02 | Version of the profile not permitted |
| — | — | yes | End | — |
| 4 | Is the transmitted version of the profile set for the transmitted start point in time higher than the highest version of the profile set processed so far at this point in time? | no | A03 | Version of the profile set not permitted |
| — | — | yes | → Step 5 | — |
| 5 | Does the stated unit of measurement of the OBIS identifier used match the unit of measurement of the normalization factor from the list of profile definitions? | no | A04 | Unit of measurement deviates from the list of profile definitions |
| — | — | yes | → Step 6 | — |
| 6 | Does the lowest temperature index value of the profile set match the limiting constant from the list of profile definitions? | no | A05 | Lowest temperature index deviates from the list of profile definitions |
| — | — | yes | → Step 7 | — |
| 7 | Does the number of temperature index values of the profile set match the expected number of temperature index values according to the reference temperature and the limiting constant from the profile definition list? | no | A06 | Number of temperature measures deviates from the list of profile definitions |
| — | — | yes | End | — |
Result codes
| Result code | Cluster | Meaning |
|---|---|---|
A01 | — | Profile or profile set does not belong to a previously subscribed profile group |
A02 | — | Version of the profile not permitted |
A03 | — | Version of the profile set not permitted |
A04 | — | Unit of measurement deviates from the list of profile definitions |
A05 | — | Lowest temperature index deviates from the list of profile definitions |
A06 | — | Number of temperature measures deviates from the list of profile definitions |
Notes on this page
Role of the numbers: »response« are the check identifiers that list this tree in the ebd_code column of the check identifier table (knowledge-collection · FV 202604); »checked« is the difference set to it from the return path of the process steps.
Not checked against a process
No consistency check was carried out for this decision tree — no generated BPMN found. Whether the MACO APP implements this tree completely is therefore not evidenced here.