Check identifier 19104 — Rejection of the request from MSB Gas
Check identifier 19104 · EDIFACT message type ORDRSP · Format version 202604
Data structure
| Structure (BO4E) | Description | Format | 19104 | Condition |
|---|---|---|---|---|
| transaktionsdaten * | — | object | Must | — |
| antwortstatus * 00010 | Response status / STS+E01 | string | Must | — |
| antwortstatusCodeliste * 00020 | Response status code list / STS+E01 | string | Must | — |
| auftragsReferenz * 00030 | Order number 'purchasing' / RFF+ON | string | X | — |
| dokumentennummer * 00040 | EDIFACT reference from the BGM segment / BGM | string | X | — |
| nachrichtendatum * 00050 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenreferenznummer * 00060 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 00070 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 00080 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00090 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| ansprechpartner * | — | object | Must | — |
| eMailAdresse 00100 | Email address | string | Must | — |
| nachname * 00110 | Surname (family name) of the contact person | string | X | — |
| rufnummern [ ] | — | object[] | May | — |
| nummerntyp 00120 | Phone number type | Enum Rufnummernart | Must | — |
RUF_ZENTRALE | — | — | Must | — |
FAX_ZENTRALE | — | — | Must | — |
SAMMELRUF | — | — | Must | — |
SAMMELFAX | — | — | Must | — |
ABTEILUNGRUF | — | — | Must | — |
ABTEILUNGFAX | — | — | Must | — |
RUF_DURCHWAHL | — | — | Must | — |
FAX_DURCHWAHL | — | — | Must | — |
MOBIL_NUMMER | — | — | Must | — |
| rufnummer 00130 | rufnummer | string | Must | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 00140 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00150 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 19104 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 ORDRSP00020 | Order response | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 10A00040 | Edition 2010 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 1.4b00060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 Z1400070 | Master data of the market or metering location | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| SG1.RFF | — | — | Must | — |
1153 ON00120 | Order number (purchasing) | — | X | — |
115400130 | Reference message number | — | X | [524] |
| SG1.RFF | — | — | Must | — |
1153 Z1300140 | Check identifier | — | X | — |
1154 1910400150 | Rejection of request from MSB gas | — | X | — |
| SG2.AJT | — | — | Must | — |
446500160 | Code of the check step | — | X | — |
1082 E_044300170 | EBD no. E_0443 | — | X | — |
| SG3.NAD | — | — | Must | — |
3035 MS00180 | Document-/message sender or sender | — | X | — |
303900190 | MP-ID | — | X | [30] ∧ [32] |
3055 900200 | GS1 | — | X | — |
3055 29300210 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG6.CTA | — | — | Must | — |
3139 IC00220 | Information contact | — | X | — |
341200230 | Contact | — | X | — |
| SG6.COM | — | — | Must | — |
314800240 | Communication address, identification | — | X | (([939] [50]) ∨ ([940] [51])) ∧ [540] |
3155 EM00250 | Electronic mail | — | X | [1P0..1] |
3155 FX00260 | Fax number | — | X | [1P0..1] |
3155 TE00270 | Telephone | — | X | [1P0..1] |
3155 AJ00280 | further telephone | — | X | [1P0..1] |
3155 AL00290 | Mobile phone | — | X | [1P0..1] |
| SG3.NAD | — | — | Must | — |
3035 MR00300 | Message recipient | — | X | — |
303900310 | MP-ID | — | X | [29] ∧ [31] |
3055 900320 | GS1 | — | X | — |
3055 33200330 | DE, DVGW Service & Consult GmbH | — | X | — |
| UNS | — | — | Must | — |
0081 S00340 | Separation of detail and summary section | — | X | — |
| UNT | — | — | Must | — |
007400350 | Number of segments in a message | — | X | — |
006200360 | Message reference number | — | X | — |
Conditions of this table
The free text of the 13 conditions referenced by the rows above. All conditions of the message type are listed in the condition index ORDRSP.
| Marker | Condition |
|---|---|
| [29] | MP-ID only from division gas |
| [30] | MP-ID only from division electricity |
| [31] | MP-ID with role MSB |
| [32] | MP-ID with role NB |
| [50] | if the code EM is present in DE3155 in the same COM |
| [51] | if the code TE / FX / AJ / AL is present in DE3155 in the same COM |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that. |
| [524] | Note: Value from BGM+Z14 DE1004 of the ORDERS with which the request from the MSB gas was made. |
| [540] | Note: Only one piece of information may be transmitted in DE3148 |
| [931] | Format: ZZZ = +00 |
| [939] | Format: the character string must contain the characters @ and . |
| [940] | Format: the character string must begin with the character + and may only be followed by digits |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
Example message
UNA:+.? '
UNB+UNOC:3+9900327000009:500+9800125000005:502+{{date}}:{{time}}+DAINLVWJUIOWMK'
UNH+DAXTOUOIXDNNWN+ORDRSP:D:10A:UN:1.4b'
BGM+Z14+DA862411191046289903323000007236480'
DTM+137:202506241231?+00:303'
RFF+ON:AFN9523'
RFF+Z13:19104'
AJT+A01+E_0443'
NAD+MS+9900327000009::293'
CTA+IC+:P GETTY'
COM+?+3222271020:TE'
NAD+MR+9800125000005::332'
UNS+S'
UNT+12+DAXTOUOIXDNNWN'
UNZ+1+DAINLVWJUIOWMK'[1 item
{6 fields
"data": {3 fields
"stammdaten": {1 field
"ANFRAGE": [1 item
{3 fields
"transaktionsdaten": {12 fields
"absender": {6 fields
"ansprechpartner": {4 fields
"rufnummern": [1 item
{2 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF, NB and MSB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | Business data request | GPKE part 4 | Electricity | Step 2 |
| NB | NB | Business data request | GPKE part 4 | Electricity | Step 2 |
| MSB | MSB | Business data request | GPKE part 4 | Electricity | Step 2 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Rejection of the request from MSB gas |
| AHB | ORDRSP AHB |
| Decision tree | E_0443 |
| Transmission channel | AS4 |
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| GPKE part 4 | Business data request | NB (electricity) → MSB (gas) | Response |
One entry from format version 202610
The check identifiers table of format version 202604 does not carry this entry: decision tree. It comes from version 202610. Everything else on this page — use case, rulebook and communication direction — comes from its own version. Before adopting this into an implementation specification, check whether what is stated applies to 202604.
Transaction and responses
Role of this check identifier: response — rejection. Basis: the transaction data carry antwortstatus and antwortstatusCodeliste; the title or the action of the Prüfi table begins with “response”; the title names a polarity (rejection).
Request: No reference recorded in the source. Neither the Prüfi table (reaktion_auf) nor the step sequence of the processes names the message that this response answers.
In which field the request is quoted
| Reference field of this message | EDIFACT segment | Target field in the request |
|---|---|---|
auftragsReferenz | SG1.RFF+ON | dokumentennummer |
RFF+ON quotes the order number; it appears in the request in segment BGM as dokumentennummer. Which request is meant is not determined on this page (see above) — the target field is thus named, but not proven.
Response codes
Decision tree: E_0443.
The Prüfi table names one further tree across all rows of this check identifier. They tie it to a process, not to a row of its handbook — their codes are therefore only on the respective tree page.
Check identifiers of the same AHB table: No other check identifier of message type ORDRSP has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 48 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains one transaction for this check identifier under the message type ordrsp. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.