Check identifier 19120 — Notification of change
Check identifier 19120 · EDIFACT message type ORDRSP · Format version 202604
This page is derived from the application handbook
The MACO APP does not carry this check identifier. The complete Prüfi pages of this level are produced from the specifications of the application — one class in the templater per check identifier — and that is where the assignment to the business objects (BO4E) comes from: which object carries which field of the message.
The catalogue of the application handbook is the larger set. This page therefore shows what the handbook itself provides — use case, process context and the AHB field list with its conditions. A data structure according to BO4E is not shown, and not because there is none, but because the application does not form one for this check identifier.
All check identifiers in this situation — and the corresponding figures — are listed by the overview of this version.
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 19120 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 ORDRSP00020 | Order response | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 10A00040 | Edition 2010 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 1.4b00060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 Z6800070 | Change | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| SG1.RFF | — | — | Must | — |
1153 ON00120 | Order number (purchasing) | — | X | — |
115400130 | Reference message number | — | X | [529] |
| SG1.RFF | — | — | Must | — |
1153 Z1300140 | Check identifier | — | X | — |
1154 1912000150 | Notification on the change | — | X | — |
| SG2.AJT | — | — | Must | — |
446500160 | Code of the check step | — | X | — |
1082 E_052600170 | EBD no. E_0526 | — | X | — |
| SG2.FTX | — | — | Must | [28] |
4451 AAP00180 | Response (free text) | — | X | — |
444000190 | Free text | — | X | — |
| SG3.NAD | — | — | Must | — |
3035 MS00200 | Document-/message sender or sender | — | X | — |
303900210 | MP-ID | — | X | [30] |
3055 900220 | GS1 | — | X | — |
3055 29300230 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG6.CTA | — | — | Must | — |
3139 IC00240 | Information contact | — | X | — |
341200250 | Contact | — | X | — |
| SG6.COM | — | — | Must | — |
314800260 | Communication address, identification | — | X | (([939] [50]) ∨ ([940] [51])) ∧ [540] |
3155 EM00270 | Electronic mail | — | X | [1P0..1] |
3155 FX00280 | Fax number | — | X | [1P0..1] |
3155 TE00290 | Telephone | — | X | [1P0..1] |
3155 AJ00300 | further telephone | — | X | [1P0..1] |
3155 AL00310 | Mobile phone | — | X | [1P0..1] |
| SG3.NAD | — | — | Must | — |
3035 MR00320 | Message recipient | — | X | — |
303900330 | MP-ID | — | X | [30] |
3055 900340 | GS1 | — | X | — |
3055 29300350 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| UNS | — | — | Must | — |
0081 S00360 | Separation of detail and summary section | — | X | — |
| UNT | — | — | Must | — |
007400370 | Number of segments in a message | — | X | — |
006200380 | Message reference number | — | X | — |
Conditions of this table
The free text of the 11 conditions referenced by the rows above. All conditions of the message type are listed in the condition index ORDRSP.
| Marker | Condition |
|---|---|
| [28] | If AJT+A99 present |
| [30] | MP-ID only from division electricity |
| [50] | if the code EM is present in DE3155 in the same COM |
| [51] | if the code TE / FX / AJ / AL is present in DE3155 in the same COM |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that. |
| [529] | Note: Document number from BGM DE1004 of the ORDERS |
| [540] | Note: Only one piece of information may be transmitted in DE3148 |
| [931] | Format: ZZZ = +00 |
| [939] | Format: the character string must contain the characters @ and . |
| [940] | Format: the character string must begin with the character + and may only be followed by digits |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are NB and MSB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| NB | NB | Order placement for a configuration from the NB to MSB | GPKE part 3 | Electricity | Step 5 |
| MSB | MSB | Order placement for a configuration from the NB to MSB | GPKE part 3 | Electricity | Step 5 |
| MSB | WMSB | Order placement for a configuration from the NB to MSB | GPKE part 3 | Electricity | Step 5 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Notification on the change |
| AHB | ORDRSP AHB |
| Response to check identifier | 17121 |
| Decision tree | E_0526 |
| Transmission channel | AS4 |
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| GPKE part 3 | Order placement for a configuration from NB to MSB | MSB → NB | Notification on the further procedure for the order placement |
One entry from format version 202610
The check identifiers table of format version 202604 does not carry this entry: decision tree. It comes from version 202610. Everything else on this page — use case, rulebook and communication direction — comes from its own version. Before adopting this into an implementation specification, check whether what is stated applies to 202604.
Notes on this page
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 51 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.