Check identifier 17121 — Order placement change
Check identifier 17121 · EDIFACT message type ORDERS · Format version 202604
Data structure
| Structure (BO4E) | Description | Format | 17121 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| ANFRAGE [ ] * | — | object[] | Must | — |
| energierichtung * 00010 | Specifies the energy direction of a market location and/or metering location | Enum Energierichtung | Must | — |
AUSSP | — | — | Must | — |
EINSP | — | — | Must | — |
| lokationsId * 00020 | Which market or metering location this request applies to. | string | X | — |
| AUFTRAG [ ] * | — | object[] | Must | — |
| ausfuehrungsdatum * 00030 | The execution date describes at which point in time an order is to be executed. | string (date-time) | X | — |
| positionsdaten [ ] | — | object[] | May | — |
| positionsnummer 00040 | Line item number | integer | X | — |
| MARKTLOKATION [ ] | — | object[] | May | — |
| zaehlwerke [ ] | — | object[] | May | — |
| messprodukt 00050 | messprodukt | string | X | — |
| verwendungszwecke [ ] | — | object[] | May | — |
| marktrolle 00060 | A market participant can take on these roles | Enum Marktrolle | Must | — |
NB | — | — | Must | — |
LF | — | — | Must | — |
MSB | — | — | Must | — |
MSBA | — | — | Must | — |
GMSB | — | — | Must | — |
MDL | — | — | Must | — |
DL | — | — | Must | — |
BKV | — | — | Must | — |
UENB | — | — | Must | — |
KUNDE-SELBST-NN | — | — | Must | — |
MGV | — | — | Must | — |
EIV | — | — | Must | — |
RB | — | — | Must | — |
KUNDE | — | — | Must | — |
INTERESSENT | — | — | Must | — |
KN | — | — | Must | — |
UBA | — | — | Must | — |
BIKO | — | — | Must | — |
ESA | — | — | Must | — |
| zweck 00070 | zweck | array | Must | — |
| zaehlzeiten | — | object | May | — |
| zaehlzeitDefinition 00080 | Metering time period definition | string | Must | — |
| MESSLOKATION [ ] | — | object[] | May | — |
| messlokationsId 00090 | The metering location identification. This is the former metering point identifier, e.g. DE 47108151234567 | string | X | — |
| zaehlwerke [ ] | — | object[] | May | — |
| messprodukt 00100 | messprodukt | string | X | — |
| notwendigkeitZweiteMessung 00110 | Necessity of second measurement | Enum NotwendigkeitZweiteMessung | X | — |
VORHANDEN | — | — | X | — |
NICHT_VORHANDEN | — | — | X | — |
| werteuebermittlungVerwendungszweck 00120 | Purpose of use for value transmission | Enum WerteuebermittlungVerwendungszweck | X | — |
VORHANDEN | — | — | X | — |
NICHT_VORHANDEN | — | — | X | — |
| zaehlzeiten | — | object | May | — |
| zaehlzeitDefinition 00130 | Metering time period definition | string | Must | — |
| NETZLOKATION [ ] | — | object[] | May | — |
| zaehlwerke [ ] | — | object[] | May | — |
| messprodukt 00140 | messprodukt | string | X | — |
| verwendungszwecke [ ] | — | object[] | May | — |
| marktrolle 00150 | A market participant can take on these roles | Enum Marktrolle | Must | — |
NB | — | — | Must | — |
LF | — | — | Must | — |
MSB | — | — | Must | — |
MSBA | — | — | Must | — |
GMSB | — | — | Must | — |
MDL | — | — | Must | — |
DL | — | — | Must | — |
BKV | — | — | Must | — |
UENB | — | — | Must | — |
KUNDE-SELBST-NN | — | — | Must | — |
MGV | — | — | Must | — |
EIV | — | — | Must | — |
RB | — | — | Must | — |
KUNDE | — | — | Must | — |
INTERESSENT | — | — | Must | — |
KN | — | — | Must | — |
UBA | — | — | Must | — |
BIKO | — | — | Must | — |
ESA | — | — | Must | — |
| zweck 00160 | zweck | array | Must | — |
| TRANCHE [ ] | — | object[] | May | — |
| tranchenId 00170 | tranchenId | string | X | — |
| zaehlwerke [ ] | — | object[] | May | — |
| messprodukt 00180 | messprodukt | string | X | — |
| verwendungszwecke [ ] | — | object[] | May | — |
| marktrolle 00190 | A market participant can take on these roles | Enum Marktrolle | Must | — |
NB | — | — | Must | — |
LF | — | — | Must | — |
MSB | — | — | Must | — |
MSBA | — | — | Must | — |
GMSB | — | — | Must | — |
MDL | — | — | Must | — |
DL | — | — | Must | — |
BKV | — | — | Must | — |
UENB | — | — | Must | — |
KUNDE-SELBST-NN | — | — | Must | — |
MGV | — | — | Must | — |
EIV | — | — | Must | — |
RB | — | — | Must | — |
KUNDE | — | — | Must | — |
INTERESSENT | — | — | Must | — |
KN | — | — | Must | — |
UBA | — | — | Must | — |
BIKO | — | — | Must | — |
ESA | — | — | Must | — |
| zweck 00200 | zweck | array | Must | — |
| transaktionsdaten * | — | object | Must | — |
| dokumentennummer * 00210 | EDIFACT reference from the BGM segment / BGM | string | X | — |
| nachrichtendatum * 00220 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenreferenznummer * 00230 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 00240 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 00250 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00260 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| ansprechpartner | — | object | May | — |
| eMailAdresse 00270 | Email address | string | Must | — |
| nachname 00280 | Surname (family name) of the contact person | string | X | — |
| rufnummern [ ] | — | object[] | May | — |
| nummerntyp 00290 | Phone number type | Enum Rufnummernart | Must | — |
RUF_ZENTRALE | — | — | Must | — |
FAX_ZENTRALE | — | — | Must | — |
SAMMELRUF | — | — | Must | — |
SAMMELFAX | — | — | Must | — |
ABTEILUNGRUF | — | — | Must | — |
ABTEILUNGFAX | — | — | Must | — |
RUF_DURCHWAHL | — | — | Must | — |
FAX_DURCHWAHL | — | — | Must | — |
MOBIL_NUMMER | — | — | Must | — |
| rufnummer 00300 | rufnummer | string | Must | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 00310 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00320 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 17121 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 ORDERS00020 | Order placement | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 09B00040 | Edition 2009 - B | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 1.4b00060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 Z6800070 | Change | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| DTM | — | — | Must | — |
2005 20300120 | Execution date/time | — | X | — |
238000130 | Date or time or time span, value | — | X | [UB1] |
2379 30300140 | CCYYMMDDHHMMZZZ | — | X | — |
| IMD | — | — | Must | — |
7081 Z1400150 | Delivery direction | — | X | — |
7009 Z0600160 | Generation | — | X | — |
7009 Z0700170 | Consumption | — | X | — |
| SG1.RFF | — | — | Must | — |
1153 Z1300180 | Check identifier | — | X | — |
1154 1712100190 | Order placement for change | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00200 | Document-/message sender or sender | — | X | — |
303900210 | MP-ID | — | X | [61] |
3055 900220 | GS1 | — | X | — |
3055 29300230 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG5.CTA | — | — | Must | — |
3139 IC00240 | Information contact | — | X | — |
341200250 | Contact | — | X | — |
| SG5.COM | — | — | Must | — |
314800260 | Communication address, identification | — | X | (([939] [147]) ∨ ([940] [148])) ∧ [567] |
3155 EM00270 | Electronic mail | — | X | [1P0..1] |
3155 FX00280 | Fax number | — | X | [1P0..1] |
3155 TE00290 | Telephone | — | X | [1P0..1] |
3155 AJ00300 | further telephone | — | X | [1P0..1] |
3155 AL00310 | Mobile phone | — | X | [1P0..1] |
| SG2.NAD | — | — | Must | — |
3035 MR00320 | Message recipient | — | X | — |
303900330 | MP-ID | — | X | [61] |
3055 900340 | GS1 | — | X | — |
3055 29300350 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 DP00360 | Supply address | — | X | — |
| SG2.LOC | — | — | Must | — |
3227 17200370 | Reporting point | — | X | — |
322500380 | Identifier | — | X | ([950] [521]) ⊻ ([960] [552]) |
| SG29.LIN | — | — | Must | — |
108200390 | Line item number | — | X | [911] |
1229 Z5400400 | Required product of the market location | — | X | — |
| SG29.PIA | — | — | Must | — |
4347 500410 | Product identification | — | X | — |
714000420 | Product code | — | X | [95] |
7143 Z1100430 | Product | — | X | — |
| SG30.CCI | — | — | Must | — |
7059 Z3900440 | Code of the metering time period definition | — | X | — |
7059 Z4100450 | No metering time period required for metering product | — | X | [75] |
703700460 | Code of the metering time period definition | — | X | [77] |
| SG30.CCI | — | — | Must | — |
7037 ZA800470 | NB | — | X | — |
| SG30.CAV | — | — | Must | — |
7111 Z8400480 | Grid usage settlement | — | X | [3P1..1] ⊻ [4P1..1] ⊻ [6P1..1] ⊻ [10P1..1] |
7111 Z8500490 | Balancing group settlement | — | X | [5P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
7111 Z8600500 | Excess/shortfall quantity settlement | — | X | [4P1..1] ⊻ [11P1..1] |
7111 Z9200510 | Transmission to the HKNR | — | X | [7P1..1] ⊻ [8P1..1] |
7111 ZE100520 | There is no purpose of use | — | X | [12P1..1] |
| SG30.CCI | — | — | Must | — |
7037 ZA700530 | LF | — | X | — |
| SG30.CAV | — | — | Must | — |
7111 Z4700540 | End customer billing | — | X | [3P1..1] ⊻ [4P0..1] ⊻ [6P1..1] ⊻ [8P1..1] ⊻ [9P1..1] ⊻ [10P0..1] ⊻ [11P1..1] |
7111 Z8400550 | Grid usage settlement | — | X | [3P0..1] ⊻ [4P0..1] ⊻ [6P0..1] ⊻ [10P0..1] |
7111 Z8500560 | Balancing group settlement | — | X | [5P1..1] ⊻ [6P1..1] ⊻ [7P1..1] ⊻ [8P1..1] |
7111 Z8600570 | Excess/shortfall quantity settlement | — | X | [4P1..1] ⊻ [11P1..1] |
7111 ZE100580 | There is no purpose of use | — | X | [12P1..1] |
| SG30.CCI | — | — | Must | — |
7037 ZA900590 | ÜNB | — | X | — |
| SG30.CAV | — | — | Must | — |
7111 Z8500600 | Balancing group settlement | — | X | [1P0..1] |
7111 ZB500610 | For the determination of the balance of balancing groups | — | X | [1P0..1] |
| SG29.LIN | — | — | Must | — |
108200620 | Line item number | — | X | [911] |
1229 Z1600630 | Required product of the tranche | — | X | — |
| SG29.PIA | — | — | Must | — |
4347 500640 | Product identification | — | X | — |
714000650 | Product code | — | X | [96] |
7143 Z1100660 | Product | — | X | — |
| SG30.CCI | — | — | Must | — |
7037 ZA800670 | NB | — | X | — |
| SG30.CAV | — | — | Must | — |
7111 Z8500680 | Balancing group settlement | — | X | [1P0..1] |
7111 Z9200690 | Transmission to the HKNR | — | X | [1P1..1] |
| SG30.CCI | — | — | Must | — |
7037 ZA700700 | LF | — | X | — |
| SG30.CAV | — | — | Must | — |
7111 Z4700710 | End customer billing | — | X | [1P1..1] |
7111 Z8500720 | Balancing group settlement | — | X | [1P1..1] |
| SG30.CCI | — | — | Must | — |
7037 ZA900730 | ÜNB | — | X | — |
| SG30.CAV | — | — | Must | — |
7111 Z8500740 | Balancing group settlement | — | X | [1P0..1] |
7111 ZB500750 | For the determination of the balance of balancing groups | — | X | [1P1..1] |
| SG34.RFF | — | — | Must | — |
1153 Z2000760 | Tranche | — | X | — |
115400770 | ID of the tranche | — | X | [950] |
| SG29.LIN | — | — | Must | — |
108200780 | Line item number | — | X | [911] |
1229 Z1900790 | Required product of the metering location | — | X | — |
| SG29.PIA | — | — | Must | — |
4347 500800 | Product identification | — | X | — |
714000810 | Product code | — | X | [100] |
7143 Z1100820 | Product | — | X | — |
| SG30.CCI | — | — | Must | — |
7059 Z3500830 | Description required value | — | X | — |
| SG30.CAV | — | — | Must | — |
7111 ZC900840 | Second measurement required for comparative measurement | — | X | — |
7110 Z0600850 | present | — | X | — |
7110 Z0700860 | not present | — | X | — |
| SG30.CAV | — | — | Must | — |
7111 Z8800870 | NB | — | X | — |
7110 Z0600880 | present | — | X | — |
7110 Z0700890 | not present | — | X | — |
| SG30.CCI | — | — | Must | — |
7059 Z3900900 | Code of the metering time period definition | — | X | — |
7059 Z4100910 | No metering time period required for metering product | — | X | [75] |
703700920 | Code of the metering time period definition | — | X | [77] |
| SG34.RFF | — | — | Must | — |
1153 Z1900930 | Metering location | — | X | — |
115400940 | ID of the metering location | — | X | [951] |
| SG29.LIN | — | — | Must | — |
108200950 | Line item number | — | X | [903] |
1229 Z5500960 | Required product of the grid location | — | X | — |
| SG29.PIA | — | — | Must | — |
4347 500970 | Product identification | — | X | — |
714000980 | Product code | — | X | [140] |
7143 Z1100990 | Product | — | X | — |
| SG30.CCI | — | — | Must | — |
7037 ZA801000 | NB | — | X | — |
| SG30.CAV | — | — | Must | — |
7111 ZD101010 | Reactive energy billing / operational management | — | X | — |
| SG30.CCI | — | — | Must | — |
7037 ZA701020 | LF | — | X | — |
| SG30.CAV | — | — | Must | — |
7111 ZD101030 | Reactive energy billing / operational management | — | X | [2P1..1] |
7111 ZE101040 | There is no purpose of use | — | X | [12P1..1] |
| UNS | — | — | Must | — |
0081 S01050 | Separation of detail and summary section | — | X | — |
| UNT | — | — | Must | — |
007401060 | Number of segments in a message | — | X | — |
006201070 | Message reference number | — | X | — |
Conditions of this table
The free text of the 42 conditions referenced by the rows above. All conditions of the message type are listed in the condition index ORDERS.
| Marker | Condition |
|---|---|
| [61] | MP-ID only from division electricity |
| [75] | If no metering time period is required for the required value |
| [77] | If code Z39 (code of the metering time period definition) is present in DE7059 in the same CCI |
| [95] | Metering product code from chapter 2.1 "Standard metering products of the market location" of the code list of configurations |
| [96] | Metering product code from chapter 2.2 "Standard metering products of the tranche" of the code list of configurations |
| [100] | Metering product code from chapter 2.3 "Standard metering products of the metering location" of the code list of configurations |
| [140] | Metering product code from chapter 2.4 "Standard metering products of the grid location" of the code list of configurations |
| [147] | if the code EM is present in DE3155 in the same COM |
| [148] | if the code TE / FX / AJ / AL is present in DE3155 in the same COM |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that. |
| [521] | Note: Use of the ID of the market location |
| [552] | Note: Use of the ID of the grid location |
| [567] | Note: Only one piece of information may be transmitted in DE3148 |
| [903] | Format: Possible value: 1 |
| [911] | Format: Possible values: 1 to n, starting at 1 for each message or segment group and ascending consecutively |
| [931] | Format: ZZZ = +00 |
| [939] | Format: the character string must contain the characters @ and . |
| [940] | Format: the character string must begin with the character + and may only be followed by digits |
| [950] | Format: market location ID |
| [951] | Format: Metering point identifier |
| [960] | Format: Grid location ID |
| [UB1] | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
| [3P1..1] | [84] IMD++Z14+Z07 present [7 6 ] If in the same SG29 with Z 54 in LIN DE1229 (Required product of the market location) the PIA+5 DE7140 with a metering product from the code list of the configurations, Kapitel 2.1.1 „ Standard metering product of the market location with the option of assigning a metering time period “ is present [ 79 ] If another SG29 with Z 54 in LIN DE1229 (Required product of the market location) with PIA+5+ 9991000000078 :Z11 (for active energy load curve 1/4-hourly) is present |
| [4P1..1] | [84] IMD++Z14+Z07 present [7 6 ] If in the same SG29 with Z54 in LIN DE1229 (Required product of the market location) the PIA+5 DE7140 with a metering product from the code list of the configurations, Kapitel 2.1.1 „ Standard metering product of the market location with the option of assigning a metering time period “ is present [80] If no other SG29 with Z 54 in LIN DE1229 (Required product of the market location) with PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present |
| [6P1..1] | [84] IMD++Z14+Z07 present [81] If in the same SG29 with Z 54 in LIN DE1229 (Required product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [83] If no other SG29 with Z 54 in LIN DE1229 (Required product of the market location) with PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 „ Standard metering product of the market location with the option of assigning a metering time period “ is present |
| [10P1..1] | [84] IMD++Z14+Z07 present [8 5 ] If in the same SG29 with Z 54 in LIN DE1229 (Required product of the market location), the PIA+5+ 9991000000086 :Z11 (active energy highest 1/4 hour in the month) is present [79] If another SG29 with Z 54 in LIN DE1229 (Required product of the market location) with PIA+5+ 9991000000078 :Z11 (for active energy load curve 1/4-hourly) is present |
| [5P0..1] | [84] IMD++Z14+Z07 present [81] If in the same SG29 with Z 54 in LIN DE1229 (Required product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [ 82 ] If another SG29 with Z 54 in LIN DE1229 (Required product of the market location) with PIA+5 DE7140 with a metering product from the code list of the configurations, Kapitel 2.1.1 „ Standard metering product of the market location with the option of assigning a metering time period “ is present |
| [6P0..1] | [84] IMD++Z14+Z07 present [81] If in the same SG29 with Z 54 in LIN DE1229 (Required product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [83] If no other SG29 with Z 54 in LIN DE1229 (Required product of the market location) with PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 „ Standard metering product of the market location with the option of assigning a metering time period “ is present |
| [7P0..1] | [35] IMD++Z14+Z06 present [81] If in the same SG29 with Z 54 in LIN DE1229 (Required product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [82] If another SG29 with Z 54 in LIN DE1229 (Required product of the market location) with PIA+5 DE7140 with a metering product from the code list of the configurations, Kapitel 2.1.1 „ Standard metering product of the market location with the option of assigning a metering time period “ is present |
| [8P0..1] | [35] IMD++Z14+Z06 present [81] If in the same SG29 with Z 54 in LIN DE1229 (Required product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [83] If no other SG29 with Z 54 in LIN DE1229 (Required product of the market location) with PIA+5 DE7140 with a metering product from the code list of the configurations, Kapitel 2.1.1 „ Standard metering product of the market location with the option of assigning a metering time period “ is present |
| [11P1..1] | [35] IMD++Z14+Z06 present [7 6 ] If in the same SG29 with Z 54 in LIN DE1229 (Required product of the market location) the PIA+5 DE7140 with a metering product from the code list of the configurations, Kapitel 2.1.1 „ Standard metering product of the market location with the option of assigning a metering time period “ is present [80] If no other SG29 with Z 54 in LIN DE1229 (Required product of the market location) with PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present |
| [7P1..1] | [35] IMD++Z14+Z06 present [81] If in the same SG29 with Z 54 in LIN DE1229 (Required product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [82] If another SG29 with Z 54 in LIN DE1229 (Required product of the market location) with PIA+5 DE7140 with a metering product from the code list of the configurations, Kapitel 2.1.1 „ Standard metering product of the market location with the option of assigning a metering time period “ is present |
| [8P1..1] | [35] IMD++Z14+Z06 present [81] If in the same SG29 with Z 54 in LIN DE1229 (Required product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [83] If no other SG29 with Z 54 in LIN DE1229 (Required product of the market location) with PIA+5 DE7140 with a metering product from the code list of the configurations, Kapitel 2.1.1 „ Standard metering product of the market location with the option of assigning a metering time period “ is present |
| [12P1..1] | [91] If no other package in this SG30 in the same SG29 LIN leads to the possibility of specifying at least one other code in this data element. |
| [4P0..1] | [84] IMD++Z14+Z07 present [7 6 ] If in the same SG29 with Z54 in LIN DE1229 (Required product of the market location) the PIA+5 DE7140 with a metering product from the code list of the configurations, Kapitel 2.1.1 „ Standard metering product of the market location with the option of assigning a metering time period “ is present [80] If no other SG29 with Z 54 in LIN DE1229 (Required product of the market location) with PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present |
| [9P1..1] | [35] IMD++Z14+Z06 present [7 6 ] If in the same SG29 with Z 54 in LIN DE1229 (Required product of the market location) the PIA+5 DE7140 with a metering product from the code list of the configurations, Kapitel 2.1.1 „ Standard metering product of the market location with the option of assigning a metering time period “ is present [79] If another SG29 with Z 54 in LIN DE1229 (Required product of the market location) with PIA+5+ 9991000000078 :Z11 (for active energy load curve 1/4-hourly) is present |
| [10P0..1] | [84] IMD++Z14+Z07 present [8 5 ] If in the same SG29 with Z 54 in LIN DE1229 (Required product of the market location), the PIA+5+ 9991000000086 :Z11 (active energy highest 1/4 hour in the month) is present [79] If another SG29 with Z 54 in LIN DE1229 (Required product of the market location) with PIA+5+ 9991000000078 :Z11 (for active energy load curve 1/4-hourly) is present |
| [3P0..1] | [84] IMD++Z14+Z07 present [7 6 ] If in the same SG29 with Z 54 in LIN DE1229 (Required product of the market location) the PIA+5 DE7140 with a metering product from the code list of the configurations, Kapitel 2.1.1 „ Standard metering product of the market location with the option of assigning a metering time period “ is present [ 79 ] If another SG29 with Z 54 in LIN DE1229 (Required product of the market location) with PIA+5+ 9991000000078 :Z11 (for active energy load curve 1/4-hourly) is present |
| [5P1..1] | [84] IMD++Z14+Z07 present [81] If in the same SG29 with Z 54 in LIN DE1229 (Required product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [ 82 ] If another SG29 with Z 54 in LIN DE1229 (Required product of the market location) with PIA+5 DE7140 with a metering product from the code list of the configurations, Kapitel 2.1.1 „ Standard metering product of the market location with the option of assigning a metering time period “ is present |
| [1P1..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
| [2P1..1] | [78] If in the same SG29 with Z55 in LIN DE1229 (Required product of the grid location) the PIA+5 DE7140 with a metering product from the code list of the configurations, chapter 2 „Code list of the standard metering product electricity for values according to type 1“ with the value property „reactive energy“ is present. |
Example message
UNA:+.? '
UNB+UNOC:3+9900259000002:500+9904629000006:500+{{date}}:{{time}}+M0LI678W'
UNH+M0V0OCVO+ORDERS:D:09B:UN:1.4b'
BGM+Z68+M05AQP3S'
DTM+137:202408190710?+00:303'
DTM+203:202409292200?+00:303'
IMD++Z14+Z07'
RFF+Z13:17121'
NAD+MS+9900259000002::293'
CTA+IC+:Laue'
COM+a.laue@conuti.de:EM'
NAD+MR+9904629000006::293'
NAD+DP'
LOC+172+44897654121'
LIN+1+Z54'
PIA+5+9991000000044:Z11'
CCI+Z39++Aal'
CCI+++ZA8'
CAV+Z84'
CCI+++ZA7'
CAV+Z84'
UNS+S'
UNT+21+M0V0OCVO'
UNZ+1+M0LI678W'[1 item
{6 fields
"data": {3 fields
"stammdaten": {3 fields
"ANFRAGE": [1 item
{6 fields
"AUFTRAG": [1 item
{4 fields
"positionsdaten": [1 item
{2 fields
"MARKTLOKATION": [1 item
{4 fields
"zaehlwerke": [1 item
{3 fields
"verwendungszwecke": [2 items
{2 fields
"zweck": [1 item
{2 fields
"zweck": [1 item
"zaehlzeiten": {1 field
"transaktionsdaten": {8 fields
"absender": {5 fields
"ansprechpartner": {4 fields
"empfaenger": {4 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are NB and MSB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| NB | NB | Order placement for a configuration from the NB to MSB | GPKE part 3 | Electricity | Step 4 |
| MSB | MSB | Order placement for a configuration from the NB to MSB | GPKE part 3 | Electricity | Step 4 |
| MSB | WMSB | Order placement for a configuration from the NB to MSB | GPKE part 3 | Electricity | Step 4 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Order placement for change |
| AHB | ORDERS AHB |
| Transmission channel | AS4 |
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| GPKE part 3 | Order placement for a configuration from NB to MSB | NB → MSB | Order placement for a configuration at the level of the directly affected location |
Transaction and responses
Role of this check identifier: request. Basis: the transaction data carry neither antwortstatus nor antwortstatusCodeliste, and neither the title nor the action of the Prüfi table begins with “response” or “response message”.
Responses: No response of this format version names this check identifier as a reference — neither explicitly in the Prüfi table nor via the step sequence. That does not mean there is none; it means that the sources do not record one.
Check identifiers of the same AHB table: No other check identifier of message type ORDERS has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 152 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains one transaction for this check identifier under the message type orders. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.