Check identifier 35003 — Request for values
Check identifier 35003 · EDIFACT message type REQOTE · Format version 202604
This page is derived from the application handbook
The MACO APP does not carry this check identifier. The complete Prüfi pages of this level are produced from the specifications of the application — one class in the templater per check identifier — and that is where the assignment to the business objects (BO4E) comes from: which object carries which field of the message.
The catalogue of the application handbook is the larger set. This page therefore shows what the handbook itself provides — use case, process context and the AHB field list with its conditions. A data structure according to BO4E is not shown, and not because there is none, but because the application does not form one for this check identifier.
All check identifiers in this situation — and the corresponding figures — are listed by the overview of this version.
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 35003 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 REQOTE00020 | Request | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 10A00040 | Edition 2010 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 1.3c00060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 Z5700070 | Transmission of values to ESA | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/ message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| DTM | — | — | Must | — |
2005 7600120 | Delivery date/time, scheduled | — | X | — |
238000130 | Date or time or time span, value | — | X | [931] |
2379 30300140 | CCYYMMDDHHMMZZZ | — | X | — |
| FTX | — | — | May | — |
4451 ACB00150 | Additional information (for general notes) | — | X | — |
444000160 | Free text | — | X | — |
| SG1.RFF | — | — | Must | — |
1153 Z1300170 | Check identifier | — | X | — |
1154 3500300180 | Request for values for ESA | — | X | — |
| SG11.NAD | — | — | Must | — |
3035 MS00190 | Document-/ message sender or sender | — | X | — |
303900200 | MP-ID | — | X | [10] |
3055 900210 | GS1 | — | X | — |
3055 29300220 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG14.CTA | — | — | Must | — |
3139 IC00230 | Information contact | — | X | — |
341200240 | Contact | — | X | — |
| SG14.COM | — | — | Must | — |
314800250 | Communication address, identification | — | X | (([939] [39]) ∨ ([940] [40])) ∧ [514] |
3155 EM00260 | Electronic mail | — | X | [1P0..1] |
3155 FX00270 | Fax number | — | X | [1P0..1] |
3155 TE00280 | Telephone | — | X | [1P0..1] |
3155 AJ00290 | further telephone | — | X | [1P0..1] |
3155 AL00300 | Mobile phone | — | X | [1P0..1] |
| SG11.NAD | — | — | Must | — |
3035 MR00310 | Message recipient | — | X | — |
303900320 | MP-ID | — | X | [10] |
3055 900330 | GS1 | — | X | — |
3055 29300340 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG11.NAD | — | — | Must | — |
3035 DP00350 | Supply address | — | X | — |
| SG11.LOC | — | — | Must | — |
3227 17200360 | Reporting point | — | X | — |
322500370 | Identifier | — | X | ([950] [502]) ⊻ ([951] [503]) ⊻ ([950] [504]) ⊻ ([960] [510]) |
| SG27.LIN | — | — | Must | — |
108200380 | Line item number | — | X | [903] |
1229 Z6700390 | Required metering product for type 2 values from the backend | — | X | — |
| SG27.PIA | — | — | Must | — |
4347 500400 | Product identification | — | X | — |
714000410 | Product code | — | X | [41] |
7143 Z1100420 | Product | — | X | — |
| SG27.LIN | — | — | Must | — |
108200430 | Line item number | — | X | [903] |
1229 Z6800440 | Required product configuration permission for values according to type 2 from SMGW | — | X | — |
| SG27.PIA | — | — | Must | — |
4347 500450 | Product identification | — | X | — |
714000460 | Product code | — | X | [42] |
7143 Z1100470 | Product | — | X | — |
| SG27.FTX | — | — | Must | [512] |
4451 Z1700480 | Destination address URI | — | X | — |
444000490 | Destination address URI IPv4 for the provision of the values | — | X | [515] |
444000500 | Destination address URI IPv6 for the provision of the values | — | X | [516] |
| SG27.FTX | — | — | Must | [512] |
4451 Z2400510 | Issuer | — | X | — |
444000520 | Certificate issuer | — | X | [967] |
| SG27.FTX | — | — | Must | [512] |
4451 Z2300530 | Certificate user (subject) | — | X | — |
444000540 | Certificate user | — | X | [967] |
| SG28.CCI | — | — | Must | — |
7059 Z6000550 | Thresholds | — | X | — |
703700560 | Metering product item code | — | X | [37] |
703600570 | upper threshold | — | X | [906] ∧ [962] |
703600580 | lower threshold | — | X | [906] ∧ [962] |
| UNS | — | — | Must | — |
0081 S00590 | Separation of detail and summary section | — | X | — |
| UNT | — | — | Must | — |
007400600 | Number of segments in a message | — | X | — |
006200610 | Message reference number | — | X | — |
Conditions of this table
The free text of the 26 conditions referenced by the rows above. All conditions of the message type are listed in the condition index REQOTE.
| Marker | Condition |
|---|---|
| [10] | MP-ID only from division electricity |
| [37] | Only the metering product position codes are permitted that are contained in chapter 4.7 „Type of values for metering products according to type 2“ of the code list of configurations. |
| [39] | if the code EM is present in DE3155 in the same COM |
| [40] | if the code TE / FX / AJ / AL is present in DE3155 in the same COM |
| [41] | Only the metering products are permitted that are contained in chapter 4.6.1 „Values according to type 2 from the backend“ of the code list of configurations. |
| [42] | Only the metering products are permitted that are contained in chapter 4.6.2 „Values according to type 2 from SMGW“ of the code list of configurations. |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that. |
| [502] | Note: Use of the ID of the market location |
| [503] | Note: Use of the ID of the metering location |
| [504] | Note: Use of the ID of the tranche |
| [510] | Note: Use of the ID of the grid location |
| [512] | Note: For receiving the values according to type 2 from the SMGW. |
| [514] | Note: Only one piece of information may be transmitted in DE3148 |
| [515] | Note: An URI IPv4 must be specified for the provision of the values. |
| [516] | Note: An URI IPv6 must be specified for the provision of the values. |
| [903] | Format: Possible value: 1 |
| [906] | Format: max. 3 decimal places |
| [931] | Format: ZZZ = +00 |
| [939] | Format: the character string must contain the characters @ and . |
| [940] | Format: the character string must begin with the character + and may only be followed by digits |
| [950] | Format: market location ID |
| [951] | Format: Metering point identifier |
| [960] | Format: Grid location ID |
| [962] | Format: max. 6 digits before the decimal point |
| [967] | Format: Certificate body in accordance with X509.1, BSI TR-03109-4 |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are MSB and ESA.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| MSB | MSB | Request and order placement of values by the ESA | WiM electricity part 2 | Electricity | Step 1 |
| ESA | ESA | Request and order placement of values by the ESA | WiM electricity part 2 | Electricity | Step 1 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Request for values |
| AHB | REQOTE AHB |
| Transmission channel | AS4 |
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| WiM electricity part 2 | Request and order placement of values by the ESA | ESA → MSB | Request for values |
Notes on this page
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 83 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.