Check identifier 35001 — Request device takeover quotation
Check identifier 35001 · EDIFACT message type REQOTE · Format version 202604
Data structure
| Structure (BO4E) | Description | Format | 35001 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| MESSLOKATION [ ] * | — | object[] | Must | — |
| messlokationsId * 00010 | The metering location identification. This is the former metering point identifier, e.g. DE 47108151234567 | string | X | — |
| transaktionsdaten * | — | object | Must | — |
| dokumentennummer * 00020 | EDIFACT reference from the BGM segment / BGM | string | X | — |
| kategorie * 00030 | Qualifier from the beginning of the EDIFACT message / BGM | string | X | — |
| lieferdatum * 00040 | Delivery date DTM+76 | string (date-time) | X | — |
| nachrichtendatum * 00050 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenreferenznummer * 00060 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| positionsnummer * 00070 | Line item number / LIN | integer | Must | — |
| pruefidentifikator * 00080 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 00090 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00100 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| ansprechpartner * | — | object | Must | — |
| eMailAdresse 00110 | Email address | string | Must | — |
| nachname * 00120 | Surname (family name) of the contact person | string | Must | — |
| rufnummern [ ] | — | object[] | May | — |
| nummerntyp 00130 | Phone number type | Enum Rufnummernart | Must | — |
RUF_ZENTRALE | — | — | Must | — |
FAX_ZENTRALE | — | — | Must | — |
SAMMELRUF | — | — | Must | — |
SAMMELFAX | — | — | Must | — |
ABTEILUNGRUF | — | — | Must | — |
ABTEILUNGFAX | — | — | Must | — |
RUF_DURCHWAHL | — | — | Must | — |
FAX_DURCHWAHL | — | — | Must | — |
MOBIL_NUMMER | — | — | Must | — |
| rufnummer 00140 | rufnummer | string | Must | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 00150 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00160 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 35001 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 REQOTE00020 | Request | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 10A00040 | Edition 2010 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 1.3c00060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 31100070 | Invitation to submit a quotation (request) | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/ message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| DTM | — | — | Must | — |
2005 7600120 | Delivery date/time, scheduled | — | X | — |
238000130 | Date or time or time span, value | — | X | [UB3] |
2379 30300140 | CCYYMMDDHHMMZZZ | — | X | — |
| SG1.RFF | — | — | Must | — |
1153 Z1300150 | Check identifier | — | X | — |
1154 3500100160 | Request for quotation for device takeover | — | X | — |
| SG11.NAD | — | — | Must | — |
3035 MS00170 | Document-/ message sender or sender | — | X | — |
303900180 | MP-ID | — | X | — |
3055 900190 | GS1 | — | X | — |
3055 29300200 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
3055 33200210 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG14.CTA | — | — | Must | — |
3139 IC00220 | Information contact | — | X | — |
341200230 | Contact | — | X | [500] |
| SG14.COM | — | — | Must | — |
314800240 | Communication address, identification | — | X | (([939] [39]) ∨ ([940] [40])) ∧ [514] |
3155 EM00250 | Electronic mail | — | X | [1P0..1] |
3155 FX00260 | Fax number | — | X | [1P0..1] |
3155 TE00270 | Telephone | — | X | [1P0..1] |
3155 AJ00280 | further telephone | — | X | [1P0..1] |
3155 AL00290 | Mobile phone | — | X | [1P0..1] |
| SG11.NAD | — | — | Must | — |
3035 MR00300 | Message recipient | — | X | — |
303900310 | MP-ID | — | X | — |
3055 900320 | GS1 | — | X | — |
3055 29300330 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
3055 33200340 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG11.NAD | — | — | Must | — |
3035 DP00350 | Supply address | — | X | — |
| SG11.LOC | — | — | Must | — |
3227 17200360 | Reporting point | — | X | — |
322500370 | Identifier | — | X | [951] [503] |
| SG27.LIN | — | — | Must | — |
108200380 | Line item number | — | X | [903] |
| UNS | — | — | Must | — |
0081 S00390 | Separation of detail and summary section | — | X | — |
| UNT | — | — | Must | — |
007400400 | Number of segments in a message | — | X | — |
006200410 | Message reference number | — | X | — |
Conditions of this table
The free text of the 13 conditions referenced by the rows above. All conditions of the message type are listed in the condition index REQOTE.
| Marker | Condition |
|---|---|
| [39] | if the code EM is present in DE3155 in the same COM |
| [40] | if the code TE / FX / AJ / AL is present in DE3155 in the same COM |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that. |
| [500] | Note: Indication of a technical contact person for the device takeover |
| [503] | Note: Use of the ID of the metering location |
| [514] | Note: Only one piece of information may be transmitted in DE3148 |
| [903] | Format: Possible value: 1 |
| [931] | Format: ZZZ = +00 |
| [939] | Format: the character string must contain the characters @ and . |
| [940] | Format: the character string must begin with the character + and may only be followed by digits |
| [951] | Format: Metering point identifier |
| [UB3] | ([931] ∧ [932] [492] ∧ [490]) ⊻ ([931] ∧ [933] [492] ∧ [491]) ⊻ ([931] ∧ [934] [493] ∧ [490]) ⊻ ([931] ∧ [935] [493] ∧ [491]) |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
Example message
UNA:+.? '
UNB+UNOC:3+9904446000007:500+9904446000007:500+{{date}}:{{time}}+YASMINJA145588'
UNH+YASMINJA086730+REQOTE:D:10A:UN:1.3c'
BGM+311+456'
DTM+137:202404011101?+00:303'
DTM+76:202403312200?+00:303'
RFF+Z13:35001'
NAD+MS+9904446000007::293'
CTA+IC+:Mustermann'
COM+mustermann@mail.com:EM'
NAD+MR+9904446000007::293'
NAD+DP'
LOC+172+DE0032106765712000000000000000060'
LIN+1'
UNS+S'
UNT+14+YASMINJA086730'
UNZ+1+YASMINJA145588'[1 item
{6 fields
"data": {3 fields
"stammdaten": {1 field
"MESSLOKATION": [1 item
{4 fields
"transaktionsdaten": {11 fields
"absender": {6 fields
"ansprechpartner": {4 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected is MSB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| MSB | MSBA | Device takeover | AWH WiM gas 2.0 | Gas | Step 1 |
| MSB | MSBA | Device takeover | WiM electricity part 1 | Electricity | Step 1 |
| MSB | MSBN | Device takeover | AWH WiM gas 2.0 | Gas | Step 1 |
| MSB | MSBN | Device takeover | WiM electricity part 1 | Electricity | Step 1 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Request for device takeover quotation |
| AHB | REQOTE AHB |
| Transmission channel | AS4 |
This check identifier is used in 3 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| WiM gas | Ch. B 5.2.3 No. 1 | MSBN → MSBA | Request device takeover quotation |
| WiM electricity part 1 | Device takeover | MSB (corresponds to MSBN on the object metering location) → MSB (corresponds to MSBA on the object metering location) | Request device takeover quotation |
| AWH WiM gas 2.0 | Device takeover | MSBN → MSBA | Request device takeover quotation |
Further relationships from format version 202610
Version 202610 also carries this check identifier in contexts that the table of version 202604 does not know; they are included in the list above. Everything else on this page — use case, rulebook and communication direction — comes from the page's own version. Before adopting it into an implementation specification, check whether what is stated applies to 202604.
Transaction and responses
Role of this check identifier: request. Basis: the transaction data carry neither antwortstatus nor antwortstatusCodeliste, and neither the title nor the action of the Prüfi table begins with “response” or “response message”.
Responses: No response of this format version names this check identifier as a reference — neither explicitly in the Prüfi table nor via the step sequence. That does not mean there is none; it means that the sources do not record one.
Check identifiers of the same AHB table: No other check identifier of message type REQOTE has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 55 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains one transaction for this check identifier under the message type reqote. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.