Check identifier 35004 — Request for a configuration
Check identifier 35004 · EDIFACT message type REQOTE · Format version 202604
Data structure
| Structure (BO4E) | Description | Format | 35004 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| AD_HOC_STEUERKANAL [ ] | — | object[] | May | — |
| konfigurationsprodukt 00010 | konfigurationsprodukt | string | X | — |
| ANFRAGE [ ] * | — | object[] | Must | — |
| anfragetyp * 00020 | Type/kind of the request (ORDERS ORDRSP IMD 7081) | Enum Anfragetyp | Must | — |
KAUF | — | — | Must | — |
NUTZUNGSUEBERLASSUNG | — | — | Must | — |
ABRECHNUNGSBRENNWERT_UND_ZUSTANDSZAHL | — | — | Must | — |
LASTGANGDATEN | — | — | Must | — |
ZAEHLERSTAENDE | — | — | Must | — |
WERTEERMITTLUNG | — | — | Must | — |
ENERGIEMENGE_EINZELWERT | — | — | Must | — |
INNERHALB_DER_ARBEITSZEIT | — | — | Must | — |
AUCH_AUSSERHALB_DER_ARBEITSZEIT | — | — | Must | — |
WECHSEL_SAEMTLICHER_EINRICHTUNGEN | — | — | Must | — |
TEILWEISER_WECHSEL | — | — | Must | — |
AENDERUNG_ZAEHLZEITDEFINITION | — | — | Must | — |
ABBESTELLUNG_ZAEHLZEITEN | — | — | Must | — |
ABBESTELLUNG_MESSPRODUKT | — | — | Must | — |
ANGEBOT_AUF_BASIS_PREISBLATT | — | — | Must | — |
INDIVIDUELLES_ANGEBOT | — | — | Must | — |
AENDERUNG_KONFIGURATION | — | — | Must | — |
KANN_NICHT_ANGEBOTEN_WERDEN | — | — | Must | — |
NEUKONFIGURATION | — | — | Must | — |
BEENDIGUNG_KONFIGURATION | — | — | Must | — |
AKTIVIERUNG_KONFIGURATION | — | — | Must | — |
| LEISTUNGSKURVENDEFINITION [ ] | — | object[] | May | — |
| leistungskurven [ ] | — | object[] | May | — |
| code 00030 | Code of the power curve | string | X | — |
| konfigurationsprodukt 00040 | Configuration product | string | X | — |
| MARKTLOKATION [ ] | — | object[] | May | — |
| marktlokationsId 00050 | Identification number of a market location at which energy is either consumed or generated | string | X | — |
| MESSLOKATION [ ] | — | object[] | May | — |
| messlokationsId 00060 | The metering location identification. This is the former metering point identifier, e.g. DE 47108151234567 | string | X | — |
| NETZLOKATION [ ] | — | object[] | May | — |
| netzlokationsId 00070 | Identification number of a grid location at which energy is either consumed or generated (like MarktlokationsId market location) | string | X | — |
| SCHALTZEITDEFINITION [ ] | — | object[] | May | — |
| schaltzeiten [ ] | — | object[] | May | — |
| code 00080 | code | string | X | — |
| konfigurationsprodukt 00090 | konfigurationsprodukt | string | X | — |
| STEUERBARE_RESSOURCE [ ] | — | object[] | May | — |
| ressourcenId 00100 | ressourcenId | string | X | — |
| TECHNISCHE_RESSOURCE [ ] | — | object[] | May | — |
| ressourcenId 00110 | ressourcenId | string | X | — |
| WERTE_NACH_TYP2 [ ] | — | object[] | May | — |
| aenderungsmoeglichkeitKonfiguration 00120 | AenderungsmoeglichkeitKonfiguration | Enum AenderungsmoeglichkeitKonfiguration | X | — |
ERFORDERLICH | — | — | X | — |
NICHT_ERFORDERLICH | — | — | X | — |
| konfigurationsprodukt 00130 | konfigurationsprodukt | string | X | — |
| messprodukt 00140 | messprodukt | string | X | — |
| aussteller | — | object | May | — |
| aussteller1 00150 | aussteller1 | string | X | — |
| aussteller2 00160 | aussteller2 | string | X | — |
| aussteller3 00170 | aussteller3 | string | X | — |
| aussteller4 00180 | aussteller4 | string | X | — |
| aussteller5 00190 | aussteller5 | string | X | — |
| schwellwerte [ ] | — | object[] | May | — |
| konfigurationsprodukt 00200 | konfigurationsprodukt | string | X | — |
| obererSchwellwert 00210 | obererSchwellwert | number (float) | X | — |
| untererSchwellwert 00220 | untererSchwellwert | number (float) | X | — |
| zertifikatsNutzer | — | object | May | — |
| zertifikatsNutzer1 00230 | zertifikatsNutzer1 | string | X | — |
| zertifikatsNutzer2 00240 | zertifikatsNutzer2 | string | X | — |
| zertifikatsNutzer3 00250 | zertifikatsNutzer3 | string | X | — |
| zertifikatsNutzer4 00260 | zertifikatsNutzer4 | string | X | — |
| zertifikatsNutzer5 00270 | zertifikatsNutzer5 | string | X | — |
| zieladresse | — | object | May | — |
| zieladresse1 00280 | zieladresse1 | string | X | — |
| zieladresse2 00290 | zieladresse2 | string | X | — |
| zieladresse3 00300 | zieladresse3 | string | X | — |
| zieladresse4 00310 | zieladresse4 | string | X | — |
| zieladresse5 00320 | zieladresse5 | string | X | — |
| transaktionsdaten * | — | object | Must | — |
| dokumentennummer * 00330 | EDIFACT reference from the BGM segment / BGM | string | Must | — |
| kategorie * 00340 | Qualifier from the beginning of the EDIFACT message / BGM | string | Must | — |
| lieferdatum 00350 | Delivery date DTM+76 | string (date-time) | X | — |
| nachrichtenReferenzBestellbestaetigung 00360 | Reference number of the message of the affected response to order placement 'order confirmation' / ORDERS RFF+Z42 | string | X | — |
| nachrichtendatum * 00370 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenreferenznummer * 00380 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| positionsnummer 00390 | Line item number / LIN | integer | X | — |
| pruefidentifikator * 00400 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| vorgangsReferenzBestellbestaetigung 00410 | Reference number of the transaction of the affected response to order placement 'order confirmation' / ORDERS RFF+Z43 | string | X | — |
| vorgangsreferenznummer 00420 | Reference number of the transaction of the registration according to WiM / ORDERS RFF+Z41 / IFTSTA RFF+ACW | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 00430 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00440 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| ansprechpartner * | — | object | Must | — |
| eMailAdresse 00450 | Email address | string | Must | — |
| nachname * 00460 | Surname (family name) of the contact person | string | Must | — |
| rufnummern [ ] | — | object[] | May | — |
| nummerntyp 00470 | Phone number type | Enum Rufnummernart | Must | — |
RUF_ZENTRALE | — | — | Must | — |
FAX_ZENTRALE | — | — | Must | — |
SAMMELRUF | — | — | Must | — |
SAMMELFAX | — | — | Must | — |
ABTEILUNGRUF | — | — | Must | — |
ABTEILUNGFAX | — | — | Must | — |
RUF_DURCHWAHL | — | — | Must | — |
FAX_DURCHWAHL | — | — | Must | — |
MOBIL_NUMMER | — | — | Must | — |
| rufnummer 00480 | rufnummer | string | Must | — |
| beteiligterMarktpartner | — | object | May | — |
| rollencodenummer 00490 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp 00500 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 00510 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00520 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 35004 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 REQOTE00020 | Request | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 10A00040 | Edition 2010 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 1.3c00060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 Z7400070 | Order placement for an offer for a configuration | — | X | [36] |
1001 Z8200080 | Order placement for an offer for a configuration by the LF | — | X | [35] |
100400090 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700100 | Document-/ message date/time | — | X | — |
238000110 | Date or time or time span, value | — | X | [931] [494] |
2379 30300120 | CCYYMMDDHHMMZZZ | — | X | — |
| DTM | — | — | Must | [16] |
2005 7600130 | Delivery date/time, scheduled | — | X | — |
238000140 | Date or time or time span, value | — | X | [UB1] |
2379 30300150 | CCYYMMDDHHMMZZZ | — | X | — |
| IMD | — | — | Must | — |
7081 Z5500160 | Change configuration | — | X | — |
7081 Z6400170 | New configuration | — | X | — |
| SG1.RFF | — | — | Must | — |
1153 Z1300180 | Check identifier | — | X | — |
1154 3500400190 | Request for a configuration | — | X | — |
| SG1.RFF | — | — | Must | — |
1153 Z4100200 | Reference number of the transaction of the registration according to WiM | — | X | — |
115400210 | Reference, identification | — | X | [507] |
| SG1.RFF | — | — | Must | — |
1153 Z4200220 | Reference number of the message of the affected response to order placement (order confirmation) | — | X | — |
115400230 | Reference, identification | — | X | [508] |
| SG1.RFF | — | — | Must | — |
1153 Z4300240 | Reference number of the transaction of the affected response to order placement (order confirmation) | — | X | — |
115400250 | Reference, identification | — | X | [509] |
| SG11.NAD | — | — | Must | — |
3035 DDM00260 | Grid operator | — | X | — |
303900270 | MP-ID | — | X | [10] |
3055 900280 | GS1 | — | X | — |
3055 29300290 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG11.NAD | — | — | Must | — |
3035 MS00300 | Document-/ message sender or sender | — | X | — |
303900310 | MP-ID | — | X | [10] |
3055 900320 | GS1 | — | X | — |
3055 29300330 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG14.CTA | — | — | Must | — |
3139 IC00340 | Information contact | — | X | — |
341200350 | Contact | — | X | — |
| SG14.COM | — | — | Must | — |
314800360 | Communication address, identification | — | X | (([939] [39]) ∨ ([940] [40])) ∧ [514] |
3155 EM00370 | Electronic mail | — | X | [1P0..1] |
3155 FX00380 | Fax number | — | X | [1P0..1] |
3155 TE00390 | Telephone | — | X | [1P0..1] |
3155 AJ00400 | further telephone | — | X | [1P0..1] |
3155 AL00410 | Mobile phone | — | X | [1P0..1] |
| SG11.NAD | — | — | Must | — |
3035 MR00420 | Message recipient | — | X | — |
303900430 | MP-ID | — | X | [10] |
3055 900440 | GS1 | — | X | — |
3055 29300450 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG11.NAD | — | — | Must | — |
3035 DP00460 | Supply address | — | X | — |
| SG11.LOC | — | — | Must | — |
3227 17200470 | Reporting point | — | X | — |
322500480 | Identifier | — | X | ([950] [502] ∧ ([20] ∨ [22])) ⊻ ([951] [503] ∧ ([22] ∨ [23])) ⊻ ([960] [510] ∧ ([20] ∨ [21] ∨ [22])) ⊻ ([961] [511] ∧ ([19] ∨ [20] ∨ [21])) |
| SG27.LIN | — | — | Must | — |
108200490 | Line item number | — | X | [903] |
1229 Z6400500 | Required product switching time definitions | — | X | — |
| SG27.PIA | — | — | Must | — |
4347 500510 | Product identification | — | X | — |
714000520 | Product code | — | X | [29] |
7143 Z1100530 | Product | — | X | — |
| SG28.CCI | — | — | Must | — |
7059 Z5200540 | Code of the switching time definition | — | X | — |
703700550 | Code of the switching time definition | — | X | — |
| SG27.LIN | — | — | Must | — |
108200560 | Line item number | — | X | [903] |
1229 Z6500570 | Required product power curve definitions | — | X | — |
| SG27.PIA | — | — | Must | — |
4347 500580 | Product identification | — | X | — |
714000590 | Product code | — | X | [30] |
7143 Z1100600 | Product | — | X | — |
| SG28.CCI | — | — | Must | — |
7059 Z5300610 | Code of the power curve definition | — | X | — |
703700620 | Code of the power curve definition | — | X | — |
| SG27.LIN | — | — | Must | — |
108200630 | Line item number | — | X | [903] |
1229 Z6600640 | Required product ad hoc control channel | — | X | — |
| SG27.PIA | — | — | Must | — |
4347 500650 | Product identification | — | X | — |
714000660 | Product code | — | X | [31] |
7143 Z1100670 | Product | — | X | — |
| SG27.LIN | — | — | Must | — |
108200680 | Line item number | — | X | [903] |
1229 Z6700690 | Required metering product for type 2 values from the backend | — | X | — |
| SG27.PIA | — | — | Must | — |
4347 500700 | Product identification | — | X | — |
714000710 | Product code | — | X | [32] |
7143 Z1100720 | Product | — | X | — |
| SG27.LIN | — | — | Must | — |
108200730 | Line item number | — | X | [903] |
1229 Z6800740 | Required product configuration permission for values according to type 2 from SMGW | — | X | — |
| SG27.PIA | — | — | Must | — |
4347 500750 | Product identification | — | X | — |
714000760 | Product code | — | X | [33] |
7143 Z1100770 | Product | — | X | — |
| SG27.FTX | — | — | Must | [512] |
4451 Z1700780 | Destination address URI | — | X | — |
444000790 | Destination address URI IPv4 for the provision of the values | — | X | [515] |
444000800 | Destination address URI IPv6 for the provision of the values | — | X | [516] |
| SG27.FTX | — | — | Must | [512] |
4451 Z2400810 | Issuer | — | X | — |
444000820 | Certificate issuer | — | X | [967] |
| SG27.FTX | — | — | Must | [512] |
4451 Z2300830 | Certificate user (subject) | — | X | — |
444000840 | Certificate user | — | X | [967] |
| SG28.CCI | — | — | Must | — |
7059 Z5400850 | Option to change the configuration in the SMGW | — | X | — |
7037 ZF700860 | independent modification option required | — | X | — |
7037 ZF800870 | independent modification option not required | — | X | — |
| SG28.CCI | — | — | Must | — |
7059 Z6000880 | Thresholds | — | X | — |
703700890 | Metering product item code | — | X | [37] |
703600900 | upper threshold | — | X | [906] ∧ [962] |
703600910 | lower threshold | — | X | [906] ∧ [962] |
| UNS | — | — | Must | — |
0081 S00920 | Separation of detail and summary section | — | X | — |
| UNT | — | — | Must | — |
007400930 | Number of segments in a message | — | X | — |
006200940 | Message reference number | — | X | — |
Conditions of this table
The free text of the 42 conditions referenced by the rows above. All conditions of the message type are listed in the condition index REQOTE.
| Marker | Condition |
|---|---|
| [10] | MP-ID only from division electricity |
| [16] | If SG1 RFF+Z41 (reference number of the registration transaction pursuant to WiM) not present |
| [19] | If SG27 LIN++Z64 (Required product switching time definitions) is present |
| [20] | If SG27 LIN++Z65 (Required product power curve definitions) is present |
| [21] | If SG27 LIN++Z66 (Required product ad hoc control channel) is present |
| [22] | If SG27 LIN++Z67 (Required metering product for values of type 2 from backend) is present |
| [23] | If SG27 LIN++Z68 (Required product configuration permission for values of type 2 from SMGW) is present |
| [29] | Only the configuration products are permitted that are contained in chapter 4.1 „Configuration products switching time definition“ of the code list of configurations. |
| [30] | Only the configuration products are permitted that are contained in chapter 4.2 „Configuration products power curve definition“ of the code list of configurations. |
| [31] | Only the configuration products are permitted that are contained in chapter 4.3 „Configuration products ad- hoc control channel“ of the code list of configurations. |
| [32] | Only the metering products are permitted that are contained in chapter 4.5 „Metering products for values according to type 2 from the backend for LF and NB“ of the code list of configurations. |
| [33] | Only the metering products are permitted that are contained in chapter 4.4 „Metering products with configuration permission for values according to type 2 from SMGW“ of the code list of configurations. |
| [35] | If MP-ID in SG11 NAD+MS with role LF is present |
| [36] | If MP-ID in SG11 NAD+MS with role NB is present |
| [37] | Only the metering product position codes are permitted that are contained in chapter 4.7 „Type of values for metering products according to type 2“ of the code list of configurations. |
| [39] | if the code EM is present in DE3155 in the same COM |
| [40] | if the code TE / FX / AJ / AL is present in DE3155 in the same COM |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that. |
| [502] | Note: Use of the ID of the market location |
| [503] | Note: Use of the ID of the metering location |
| [507] | Note: Transaction number from SG4 IDE+24 DE7402 of the UTILMD with BGM+E01 with which the registration of the MSB switch was carried out. |
| [508] | Note: Value from BGM+Z73 DE1004 of the IFTSTA with which the response to the order placement for the configuration was transmitted |
| [509] | Note: Transaction number from CNI DE1490 of the IFTSTA with BGM+Z73 with which the response to the order placement of the configuration was transmitted |
| [510] | Note: Use of the ID of the grid location |
| [511] | Note: Use of the ID of the controllable resource |
| [512] | Note: For receiving the values according to type 2 from the SMGW. |
| [514] | Note: Only one piece of information may be transmitted in DE3148 |
| [515] | Note: An URI IPv4 must be specified for the provision of the values. |
| [516] | Note: An URI IPv6 must be specified for the provision of the values. |
| [903] | Format: Possible value: 1 |
| [906] | Format: max. 3 decimal places |
| [931] | Format: ZZZ = +00 |
| [939] | Format: the character string must contain the characters @ and . |
| [940] | Format: the character string must begin with the character + and may only be followed by digits |
| [950] | Format: market location ID |
| [951] | Format: Metering point identifier |
| [960] | Format: Grid location ID |
| [961] | Format: SR-ID |
| [962] | Format: max. 6 digits before the decimal point |
| [967] | Format: Certificate body in accordance with X509.1, BSI TR-03109-4 |
| [UB1] | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
Example message
Example 1
UNA:+.? '
UNB+UNOC:3+9900496000001:500+9900496000002:500+{{date}}:{{time}}+M3VQCXCY'
UNH+UNHM3Q4M8YM+REQOTE:D:10A:UN:1.3c'
BGM+Z82+BGMM3TJAKY3'
DTM+137:202410160945?+00:303'
DTM+76:202501052300?+00:303'
IMD++Z55'
RFF+Z13:35004'
RFF+Z42:BGMM44X6WGM'
RFF+Z43:45261'
NAD+MS+9900496000001::293'
CTA+IC+:Max Mustermann'
COM+Max.Mustermann@conuti.de:EM'
NAD+MR+9900496000002::293'
NAD+DP'
LOC+172+50444001616'
LIN+1+Z65'
PIA+5+9991000000721:Z11'
CCI+Z53++MMA'
UNS+S'
UNT+19+UNHM3Q4M8YM'
UNZ+1+M3VQCXCY'[1 item
{6 fields
"data": {3 fields
"stammdaten": {3 fields
"ANFRAGE": [1 item
{3 fields
"MARKTLOKATION": [1 item
{5 fields
"marktlokationsTyp": [1 item
{1 field
"LEISTUNGSKURVENDEFINITION": [1 item
{3 fields
"leistungskurven": [1 item
{2 fields
"transaktionsdaten": {13 fields
"absender": {6 fields
"ansprechpartner": {4 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Example 2
UNA:+.? '
UNB+UNOC:3+9900496000001:500+9900496000002:500+{{date}}:{{time}}+M3VQCXCY'
UNH+UNHM3Q4M8YM+REQOTE:D:10A:UN:1.3c'
BGM+Z82+BGMM3TJAKY3'
DTM+137:202410160945?+00:303'
DTM+76:202501052300?+00:303'
IMD++Z55'
RFF+Z13:35004'
RFF+Z42:BGMM44X6WGM'
RFF+Z43:45261'
NAD+MS+9900496000001::293'
CTA+IC+:Max Mustermann'
COM+Max.Mustermann@conuti.de:EM'
NAD+MR+9900496000002::293'
NAD+DP'
LOC+172+C816417ST77'
LIN+1+Z64'
PIA+5+9991000000713:Z11'
CCI+Z52++AAL'
LIN+1+Z65'
PIA+5+9991000000721:Z11'
CCI+Z53++MMA'
LIN+1+Z66'
PIA+5+9991000000739:Z11'
UNS+S'
UNT+24+UNHM3Q4M8YM'
UNZ+1+M3VQCXCY'[1 item
{6 fields
"data": {3 fields
"stammdaten": {5 fields
"ANFRAGE": [1 item
{3 fields
"STEUERBARE_RESSOURCE": [1 item
{4 fields
"SCHALTZEITDEFINITION": [1 item
{3 fields
"schaltzeiten": [1 item
{2 fields
"LEISTUNGSKURVENDEFINITION": [1 item
{3 fields
"leistungskurven": [1 item
{2 fields
"AD_HOC_STEUERKANAL": [1 item
{3 fields
"transaktionsdaten": {13 fields
"absender": {6 fields
"ansprechpartner": {4 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Example 3
UNA:+.? '
UNB+UNOC:3+9900496000001:500+9900496000002:500+{{date}}:{{time}}+M3VQCXCY'
UNH+UNHM3Q4M8YM+REQOTE:D:10A:UN:1.3c'
BGM+Z82+BGMM3TJAKY3'
DTM+137:202410160945?+00:303'
DTM+76:202501052300?+00:303'
IMD++Z55'
RFF+Z13:35004'
RFF+Z42:BGMM44X6WGM'
RFF+Z43:45261'
NAD+MS+9900496000001::293'
CTA+IC+:Max Mustermann'
COM+Max.Mustermann@conuti.de:EM'
NAD+MR+9900496000002::293'
NAD+DP'
LOC+172+E1688001818'
LIN+1+Z65'
PIA+5+9991000000721:Z11'
CCI+Z53++MMA'
LIN+1+Z66'
PIA+5+9991000000739:Z11'
UNS+S'
UNT+21+UNHM3Q4M8YM'
UNZ+1+M3VQCXCY'[1 item
{6 fields
"data": {3 fields
"stammdaten": {4 fields
"ANFRAGE": [1 item
{3 fields
"NETZLOKATION": [1 item
{4 fields
"LEISTUNGSKURVENDEFINITION": [1 item
{3 fields
"leistungskurven": [1 item
{2 fields
"AD_HOC_STEUERKANAL": [1 item
{3 fields
"transaktionsdaten": {13 fields
"absender": {6 fields
"ansprechpartner": {4 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Example 4
UNA:+.? '
UNB+UNOC:3+9900496000001:500+9900496000002:500+{{date}}:{{time}}+M3VQCXCY'
UNH+UNHM3Q4M8YM+REQOTE:D:10A:UN:1.3c'
BGM+Z82+BGMM3TJAKY3'
DTM+137:202410160945?+00:303'
DTM+76:202501052300?+00:303'
IMD++Z55'
RFF+Z13:35004'
RFF+Z42:BGMM44X6WGM'
RFF+Z43:45261'
NAD+MS+9900496000001::293'
CTA+IC+:Max Mustermann'
COM+Max.Mustermann@conuti.de:EM'
NAD+MR+9900496000002::293'
NAD+DP'
LOC+172+DE0032106765712000000000000001717'
LIN+1+Z68'
PIA+5+9991000000812:Z11'
FTX+Z17+++https?://conuti.de:X'
FTX+Z24+++SERIALNUMBER = 3, C = DE, O = SM-PKI-DE, CN = T-Systems-EnergyCA.CA'
FTX+Z23+++L = Stadt, SERIALNUMBER = 1, C = DE,OU = Firma GmbH, O = SM-PKI-DE,CN = Firma.EMT.Erweiterung:X:X:X:X'
CCI+Z54++ZF7'
UNS+S'
UNT+22+UNHM3Q4M8YM'
UNZ+1+M3VQCXCY'[1 item
{6 fields
"data": {3 fields
"stammdaten": {3 fields
"ANFRAGE": [1 item
{3 fields
"MESSLOKATION": [1 item
{4 fields
"WERTE_NACH_TYP2": [1 item
{8 fields
"schwellwerte": [1 item
{3 fields
"zieladresse": {2 fields
"aussteller": {1 field
"zertifikatsNutzer": {5 fields
"transaktionsdaten": {13 fields
"absender": {6 fields
"ansprechpartner": {4 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF, NB and MSB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | Order placement for a configuration from the LF to MSB | GPKE part 3 | Electricity | Step 1 |
| NB | NB | Order placement for a configuration from the NB to MSB | GPKE part 3 | Electricity | Step 1 |
| MSB | MSB | Order placement for a configuration from the LF to MSB | GPKE part 3 | Electricity | Step 1 |
| MSB | MSB | Order placement for a configuration from the NB to MSB | GPKE part 3 | Electricity | Step 1 |
| MSB | WMSB | Order placement for a configuration from the LF to MSB | GPKE part 3 | Electricity | Step 1 |
| MSB | WMSB | Order placement for a configuration from the NB to MSB | GPKE part 3 | Electricity | Step 1 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Request for a configuration |
| AHB | REQOTE AHB |
| Transmission channel | AS4 |
This check identifier is used in 2 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| GPKE part 3 | Order placement for a configuration from NB to MSB | NB → MSB | Request for a configuration at the level of the directly affected location |
| GPKE part 3 | Order placement for a configuration from LF to MSB | LF → MSB | Request for a configuration at the level of the directly affected location |
Transaction and responses
Role of this check identifier: request. Basis: the transaction data carry neither antwortstatus nor antwortstatusCodeliste, and neither the title nor the action of the Prüfi table begins with “response” or “response message”.
Which messages respond to this
| Role | Check identifier | Use case | Message type | Origin of supply |
|---|---|---|---|---|
| Response | 21033 | Rejection of the request | IFTSTA | from the step sequence |
This column is the inverse of the assignment on the response pages — not the next step of a list. The process source says of its own steps that they are »possible messages, not a sequence«.
Check identifiers of the same AHB table: No other check identifier of message type REQOTE has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 129 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains 4 transactions for this check identifier under the message type reqote. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.