The MACO APP does not carry this check identifier. The complete Prüfi pages of this level are produced from the specifications of the application — one class in the templater per check identifier — and that is where the assignment to the business objects (BO4E) comes from: which object carries which field of the message.
The catalogue of the application handbook is the larger set. This page therefore shows what the handbook itself provides — use case, process context and the AHB field list with its conditions. A data structure according to BO4E is not shown, and not because there is none, but because the application does not form one for this check identifier.
All check identifiers in this situation — and the corresponding figures — are listed by the overview of this version.
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 35005 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 REQOTE00020 | Request | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 10A00040 | Edition 2010 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 1.3c00060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 Z9300070 | Order placement for an offer for a change of the technology of the location | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| DTM | — | — | Must | — |
2005 46900120 | Start date or point in time, earliest | — | X | — |
238000130 | Date or time or time span, value | — | X | [UB1] [520] |
2379 30300140 | CCYYMMDDHHMMZZZ | — | X | — |
| DTM | — | — | Must | — |
2005 47200150 | End date or time, latest | — | X | — |
238000160 | Date or time or time span, value | — | X | [UB1] [521] |
2379 30300170 | CCYYMMDDHHMMZZZ | — | X | — |
| FTX | — | — | Should | [35] ∧ [53] |
4451 Z1300180 | Website | — | X | — |
444100190 | Password | — | X | — |
444000200 | Link to the power of attorney of the customer | — | X | — |
| SG1.RFF | — | — | Must | — |
1153 Z1300210 | Check identifier | — | X | — |
1154 3500500220 | Request for quotation for technical change | — | X | — |
| SG11.NAD | — | — | Must | — |
3035 MS00230 | Document-/message sender or sender | — | X | — |
303900240 | MP-ID | — | X | [10] |
3055 900250 | GS1 | — | X | — |
3055 29300260 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG11.NAD | — | — | Must | — |
3035 MR00270 | Message recipient | — | X | — |
303900280 | MP-ID | — | X | [10] |
3055 900290 | GS1 | — | X | — |
3055 29300300 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG11.NAD | — | — | Must | — |
3035 DP00310 | Supply address | — | X | — |
| SG11.LOC | — | — | Must | — |
3227 17200320 | Reporting point | — | X | — |
322500330 | Identifier | — | X | ([951] [503]) ⊻ ([961] [511]) ⊻ ([960] [510]) |
| SG12.RFF | — | — | Must | — |
1153 Z1800340 | Market location | — | X | — |
115400350 | ID of the market location | — | X | [950] |
| SG12.RFF | — | — | Must | — |
1153 Z3700360 | Technical resource | — | X | — |
115400370 | ID of the technical resource | — | X | [922] [517] |
| SG11.NAD | — | — | Must | — |
3035 Z0900380 | Customer of the LF | — | X | — |
| SG14.CTA | — | — | — | — |
3139 IC00390 | Information point | — | X | — |
341200400 | Contact details | — | X | — |
| SG14.COM | — | — | Must | — |
314800410 | Number / address | — | X | (([939] [39]) ∨ ([940] [52])) ∧ [514] |
3155 EM00420 | — | X | [1P0..1] | |
3155 TE00430 | Telephone | — | X | [1P0..1] |
3155 AL00440 | Mobile phone | — | X | [1P0..1] |
| SG27.LIN | — | — | Must | — |
108200450 | Line item number | — | X | [911] |
1229 Z1900460 | Required product of the metering location | — | X | — |
| SG27.PIA | — | — | Must | — |
4347 500470 | Product identification | — | X | — |
714000480 | Product code | — | X | [47] ∧ (([35] ∧ [49]) ⊻ ([36] ∧ [48])) |
7143 Z1100490 | Product | — | X | — |
| SG27.LIN | — | — | Must | — |
108200500 | Line item number | — | X | [911] |
1229 Z5500510 | Required product of the grid location | — | X | — |
| SG27.PIA | — | — | Must | — |
4347 500520 | Product identification | — | X | — |
714000530 | Product code | — | X | [50] ∧ (([35] ∧ [49]) ⊻ ([36] ∧ [48])) |
7143 Z1100540 | Product | — | X | — |
| SG27.LIN | — | — | Must | — |
108200550 | Line item number | — | X | [911] |
1229 Z5600560 | Required product of the controllable resource | — | X | — |
| SG27.PIA | — | — | Must | — |
4347 500570 | Product identification | — | X | — |
714000580 | Product code | — | X | [51] ∧ (([35] ∧ [49]) ⊻ ([36] ∧ [48])) |
7143 Z1100590 | Product | — | X | — |
| UNS | — | — | Must | — |
0081 S00600 | Separation of detail and summary section | — | X | — |
| UNT | — | — | Must | — |
007400610 | Number of segments in a message | — | X | — |
006200620 | Message reference number | — | X | — |
Conditions of this table
The free text of the 30 conditions referenced by the rows above. All conditions of the message type are listed in the condition index REQOTE.
| Marker | Condition |
|---|---|
| [10] | MP-ID only from division electricity |
| [35] | If MP-ID in SG11 NAD+MS with role LF is present. |
| [36] | If MP-ID in SG11 NAD+MS with role NB is present. |
| [39] | If code EM is present in DE3155 in the same COM. |
| [47] | Only the product codes are permitted that are present with the value "Metering location" in the column "Level" in chapter 7 "Products for the order placement of a change at a location" of the code list of configurations. |
| [48] | Furthermore, only the product codes are permitted that are marked with an "X" in the column "NB" within the column "Product orderable from MSB by market role" in chapter 7 "Products for the order placement of a change at a location" of the code list of configurations. |
| [49] | Furthermore, only the product codes are permitted that are marked with an "X" in the column "LF" within the column "Product orderable from MSB by market role" in chapter 7 "Products for the order placement of a change at a location" of the code list of configurations. |
| [50] | Only the product codes are permitted that are present with the value "Grid location" in the column "Level" in chapter 7 "Products for the order placement of a change at a location" of the code list of configurations. |
| [51] | Only the product codes are permitted that are present with the value "Controllable resource" in the column "Level" in chapter 7 "Products for the order placement of a change at a location" of the code list of configurations. |
| [52] | If code TE / AL is present in DE3155 in the same COM. |
| [53] | If the LF of the market location is not assigned to the named location in the requested implementation period. |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that. |
| [503] | Note: Use of the ID of the metering location |
| [510] | Note: Use of the ID of the grid location |
| [511] | Note: Use of the ID of the controllable resource |
| [514] | Note: Only one piece of information may be transmitted in DE3148 |
| [517] | Note: Use of the ID of the technical resource |
| [520] | Note: Statement of the start point in time of the desired implementation date from the requesting party's point of view. |
| [521] | Note: Indication of the end point in time of the desired implementation date from the requester's perspective. |
| [911] | Format: Possible values: 1 to n, starting at 1 for each message or segment group and ascending consecutively |
| [922] | Format: TR-ID |
| [931] | Format: ZZZ = +00 |
| [939] | Format: the character string must contain the characters @ and . |
| [940] | Format: the character string must begin with the character + and may only be followed by digits |
| [950] | Format: market location ID |
| [951] | Format: Metering point identifier |
| [960] | Format: Grid location ID |
| [961] | Format: SR-ID |
| [UB1] | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF, NB and MSB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | Metering location change from the LF to MSB | AWH processes for changing the technology at locations | Electricity | Step 1 |
| NB | NB | Metering location change from the NB to MSB | AWH processes for changing the technology at locations | Electricity | Step 1 |
| MSB | MSB-MELO | Metering location change from the LF to MSB | AWH processes for changing the technology at locations | Electricity | Step 1 |
| MSB | MSB-MELO | Metering location change from the NB to MSB | AWH processes for changing the technology at locations | Electricity | Step 1 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Request for quotation for technical change |
| AHB | REQOTE AHB |
| Transmission channel | AS4 |
This check identifier is used in 2 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| AWH processes for changing the technology at locations | Metering location change from NB to MSB | NB → MSB (corresponds to MSB on the metering location object) | Request for a quotation for the metering location change |
| AWH processes for changing the technology at locations | Metering location change from LF to MSB | LF → MSB (corresponds to MSB on the metering location object) | Request for a quotation for the metering location change |
Notes on this page
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 86 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.