Transmission of meter readings from LF — LF view
The LF or NB transmits the meter reading to the MSB of the metering location that was assigned to the metering location at the time of the reading.
Process flow from the perspective of the LF
Process steps
Meter reading (metering location)
LF MSB (metering location)Check identifiers
- 13017 — Meter reading (electricity) · AS4
Flow
Prozessauslöser
START_ERHEBUNG_MESSWERTEThe backend triggers this step with this event.
Message to MSB (metering location) · AS4
Write endpoint
- Transaction updated — Update process data
POST /updateProcessData
Updates the existing transaction in the backend once the message has been created.
- Transaction updated — Update process data
Process information
Wording of the consolidated version, profile ch. 2.9.1.1, p. 58.
Preconditions
- The MSB of the metering location knows the metering location.
- As part of a reading for kME without RLM or mME, the LF or NB has a self-recorded meter reading or a meter reading from a customer reading.
Results
The meter reading previously plausibility-checked by the MSB of the metering location is only transmitted to the MSB of the market location once a trigger for transmission (chapter 2.5.5. “Presentation of the values to be transmitted”) exists.
First message
The party involved on this page is itself the sender of: „Meter reading (metering location)“ to MSB (metering location) (step 1).
Objective
The LF or NB has transmitted the meter reading to the MSB of the metering location.
Other views of the process
The same process through the eyes of the other parties involved: the same steps, each read from their point of view.
- View MSB-MELO — MSB at the metering location object · market role MSB
Notes on this page
The steps are the possible messages of this process, not a sequence — the source lists neither conditions nor alternatives. The small box on the step names the own view on the left: with ← it receives, with → it sends. Collapsed steps run between other market partners.