Check identifier 13017 — Meter reading (Electricity)
Check identifier 13017 · EDIFACT message type MSCONS · Format version 202610
Data structure
| Structure (BO4E) | Description | Format | 13017 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| ENERGIEMENGE [ ] * | — | object[] | Must | — |
| konfiguration 00010 | konfiguration | string | X | — |
| lokationsId * 00020 | Unique number of the market location or of the metering location to which the energy quantity belongs | string | X | — |
| energieverbrauch [ ] * | — | object[] | Must | — |
| ablesedatum 00030 | ablesedatum | string (date-time) | X | — |
| ausfuehrungszeitpunkt 00040 | ausfuehrungszeitpunkt | string (date-time) | X | — |
| messwertstatus * 00050 | The status of a meter reading | Enum Messwertstatus | Must | — |
ABGELESEN | — | — | Must | — |
ERSATZWERT | — | — | Must | — |
VORSCHLAGSWERT | — | — | Must | — |
NICHT_VERWENDBAR | — | — | Must | — |
PROGNOSEWERT | — | — | Must | — |
ENERGIEMENGESUMMIERT | — | — | Must | — |
VOLAEUFIGERWERT | — | — | Must | — |
FEHLT | — | — | Must | — |
ANGABE_FUER_LIEFERSCHEIN | — | — | Must | — |
GRUNDLAGE_POG_ERMITTLUNG | — | — | Must | — |
| nutzungszeitpunkt * 00060 | nutzungszeitpunkt | string (date-time) | X | — |
| obiskennzahl * 00070 | obiskennzahl | string | X | — |
| position * 00080 | position | integer | Must | — |
| wert * 00090 | wert | number (float) | Must | — |
| statuszusatzinformationen [ ] | — | object[] | May | — |
| art 00100 | Status type | Enum StatusArt | X | — |
PLAUSIBILISIERUNGSHINWEIS | — | — | X | — |
ERSATZWERTBILDUNGSVERFAHREN | — | — | X | — |
KORREKTURGRUND | — | — | X | — |
GRUND_ERSATZWERTBILDUNGSVERFAHREN | — | — | X | — |
GASQUALITAET | — | — | X | — |
MESSKLASSIFIZIERUNG | — | — | X | — |
| status 00110 | Status | Enum Status | X | — |
KUNDENSELBSTABLESUNG | — | — | X | — |
LEERSTAND | — | — | X | — |
REALER_ZAEHLERUEBERLAUF_GEPRUEFT | — | — | X | — |
PLAUSIBEL_WG_KONTROLLABLESUNG | — | — | X | — |
PLAUSIBEL_WG_KUNDENHINWEIS | — | — | X | — |
AUSTAUSCH_DES_ERSATZWERTES | — | — | X | — |
RECHENWERT | — | — | X | — |
BASIS_MME | — | — | X | — |
VERGLEICHSMESSUNG_GEEICHT | — | — | X | — |
VERGLEICHSMESSUNG_NICHT_GEEICHT | — | — | X | — |
MESSWERTNACHBILDUNG_AUS_GEEICHTEN_WERTEN | — | — | X | — |
MESSWERTNACHBILDUNG_AUS_NICHT_GEEICHTEN_WERTEN | — | — | X | — |
INTERPOLATION | — | — | X | — |
HALTEWERT | — | — | X | — |
BILANZIERUNG_NETZABSCHNITT | — | — | X | — |
HISTORISCHE_MESSWERTE | — | — | X | — |
STATISTISCHE_METHODE | — | — | X | — |
AUFTEILUNG | — | — | X | — |
VERWENDUNG_VON_WERTEN_DES_STOERMENGENZAEHLWERKS | — | — | X | — |
UMGANGS_UND_KORREKTURMENGEN | — | — | X | — |
ANGABEN_MESSLOKATION | — | — | X | — |
KEIN_ZUGANG | — | — | X | — |
KOMMUNIKATIONSSTOERUNG | — | — | X | — |
NETZAUSFALL | — | — | X | — |
SPANNUNGSAUSFALL | — | — | X | — |
STATUS_GERAETEWECHSEL | — | — | X | — |
KALIBRIERUNG | — | — | X | — |
GERAET_ARBEITET_AUSSERHALB_DER_BETRIEBSBEDINGUNGEN | — | — | X | — |
MESSEINRICHTUNG_GESTOERT_DEFEKT | — | — | X | — |
UNSICHERHEIT_MESSUNG | — | — | X | — |
BERUECKSICHTIGUNG_STOERMENGENZAEHLWERK | — | — | X | — |
MENGENUMWERTUNG_VOLLSTAENDIG | — | — | X | — |
UHRZEIT_GESTELLT_SYNCHRONISATION | — | — | X | — |
MESSWERT_UNPLAUSIBEL | — | — | X | — |
FALSCHER_WANDLERFAKTOR | — | — | X | — |
FEHLERHAFTE_ABLESUNG | — | — | X | — |
AENDERUNG_DER_BERECHNUNG | — | — | X | — |
UMBAU_DER_MESSLOKATION | — | — | X | — |
DATENBEARBEITUNGSFEHLER | — | — | X | — |
BRENNWERTKORREKTUR | — | — | X | — |
Z_ZAHL_KORREKTUR | — | — | X | — |
STOERUNG_DEFEKT_MESSEINRICHTUNG | — | — | X | — |
AENDERUNG_TARIFSCHALTZEITEN | — | — | X | — |
TARIFSCHALTGERAET_DEFEKT | — | — | X | — |
IMPULSWERTIGKEIT_NICHT_AUSREICHEND | — | — | X | — |
ENERGIEMENGE_IN_UNGEMESSENEM_ZEITINTERVALL | — | — | X | — |
ENERGIEMENGE_AUS_DEM_UNGEPAIRTEN_ZEITINTERVALL | — | — | X | — |
WARTUNGSARBEITEN_AN_GEEICHTEM_MESSGERAET | — | — | X | — |
GESTOERTE_WERTE | — | — | X | — |
WARTUNGSARBEITEN_AN_EICHRECHTSKONFORMEN_MESSGERAETEN | — | — | X | — |
KONSISTENZ_UND_SYNCHRONPRUEFUNG | — | — | X | — |
GRUND_ANGABEN_MESSLOKATION | — | — | X | — |
ANFORDERUNG_IN_DIE_VERGANGENHEIT_ZUM_ANGEFORDERTEN_ZEITPUNKT_LIEGT_KEIN_WERT_VOR | — | — | X | — |
UMSTELLUNG_GASQUALITAET | — | — | X | — |
ZAEHLERSTAND_ZUM_BEGINN_DER_ANGEGEBENEN_ENERGIEMENGE_VORHANDEN_UND_KOMMUNIZIERT | — | — | X | — |
ZAEHLERSTAND_ZUM_ENDE_DER_ANGEGEBENEN_ENERGIEMENGE_VORHANDEN_UND_KOMMUNIZIERT | — | — | X | — |
ZAEHLERSTAND_ZUM_BEGINN_DER_ANGEGEBENEN_ENERGIEMENGE_NICHT_VORHANDEN_DA_MENGENABGRENZUNG | — | — | X | — |
ZAEHLERSTAND_ZUM_ENDE_DER_ANGEGEBENEN_ENERGIEMENGE_NICHT_VORHANDEN_DA_MENGENABGRENZUNG | — | — | X | — |
GESCHEITERT | — | — | X | — |
AUSGEBAUT | — | — | X | — |
| ZAEHLER [ ] | — | object[] | May | — |
| zaehlernummer 00120 | Numbering of the meter, assigned by the metering point operator | string | X | — |
| transaktionsdaten * | — | object | Must | — |
| anfrageReferenz 00130 | Application number / RFF+AGI | string | X | — |
| dokumentennummer * 00140 | EDIFACT reference from the BGM segment / BGM | string | Must | — |
| kategorie * 00150 | Qualifier from the beginning of the EDIFACT message / BGM | string | Must | — |
| nachrichtendatum * 00160 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenfunktion * 00170 | Message function code / BGM | string | Must | — |
| nachrichtenreferenznummer * 00180 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 00190 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 00200 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00210 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 00220 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00230 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 13017 | Condition |
|---|---|---|---|---|
| UNB | — | — | Must | — |
0001 UNOC00010 | UN/ECE character set C | — | X | — |
0002 300020 | Version 3 | — | X | — |
000400030 | MP-ID Sender | — | X | — |
0007 1400040 | GS1 | — | X | — |
0007 50000050 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
001000060 | MP-ID recipient | — | X | — |
0007 1400070 | GS1 | — | X | — |
0007 50000080 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
001700090 | Date of creation | — | X | — |
001900100 | Time of creation | — | X | — |
002000110 | Interchange control reference | — | X | [918] |
0026 VL00120 | Settlement list, meter reading | — | X | — |
0035 100130 | Transmission file is a test | — | — | S [155] |
| UNH | — | — | Must | — |
006200140 | Message reference number | — | X | — |
0065 MSCONS00150 | Report on the consumption of measurable services | — | X | — |
0052 D00160 | Draft version | — | X | — |
0054 04B00170 | Edition 2004 - B | — | X | — |
0051 UN00180 | UN/CEFACT | — | X | — |
0057 2.500190 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 700200 | Process data report | — | X | — |
100400210 | Document number | — | X | — |
1225 900220 | Original | — | X | — |
| DTM | — | — | Must | — |
2005 13700230 | Document-/message date/time | — | X | — |
238000240 | Date or time or time span, value | — | X | [931] [494] |
2379 30300250 | CCYYMMDDHHMMZZZ | — | X | — |
| SG1.RFF | — | — | Must | — |
1153 AGI00260 | Application number | — | X | — |
115400270 | Reference number | — | X | ([67] ∧ ([529] ∨ [553])) |
| SG1.RFF | — | — | Must | — |
1153 Z1300280 | Check identifier | — | X | — |
1154 1301700290 | Meas. val. meter reading (electricity) | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00300 | Document-/message sender or sender | — | X | — |
303900310 | MP-ID | — | X | [117] |
3055 900320 | GS1 | — | X | — |
3055 29300330 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MR00340 | Message recipient | — | X | — |
303900350 | MP-ID | — | X | [117] |
3055 900360 | GS1 | — | X | — |
3055 29300370 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| UNS | — | — | Must | — |
0081 D00380 | Separation of header and detail section | — | X | — |
| SG5.NAD | — | — | Must | — |
3035 DP00390 | Supply address | — | X | — |
| SG6.LOC | — | — | Must | — |
3227 17200400 | Reporting point | — | X | — |
322500410 | Designation | — | — | M [131] ∧ ([951] ∧ [510]) |
| SG7.RFF | — | — | Must | — |
1153 MG00420 | Device number | — | X | — |
115400430 | Device number | — | X | — |
| SG7.RFF | — | — | Must | — |
1153 AGK00440 | Application reference number | — | X | — |
115400450 | Configuration ID | — | X | [567] |
| SG9.LIN | — | — | Must | — |
108200460 | Line item number | — | X | [908] |
| SG9.PIA | — | — | Must | — |
4347 500470 | Product identification | — | X | — |
714000480 | Medium / OBIS code number | — | X | [501] ∧ [566] |
7143 SRW00490 | OBIS code | — | X | — |
| SG10.QTY | — | — | Must | — |
6063 22000500 | True value | — | X | — |
6063 6700510 | Substitute value | — | X | [35] ∨ ([32] ∧ [77]) |
6063 Z1800520 | Preliminary value | — | X | [35] ∧ [113] |
606000530 | Quantity | — | X | [902] ∧ [906] |
| SG10.DTM | — | — | Should | [93] ∧ [128] ∧ [131] ∧ [569] |
2005 900540 | Handling/processing date/time | — | X | — |
238000550 | Date or time or time span, value | — | X | ([931] [111] ∧ [495]) ⊻ ([134] ∧ [135]) |
2379 10200560 | CCYYMMDD | — | X | — |
2379 30300570 | CCYYMMDDHHMMZZZ | — | X | — |
| SG10.DTM | — | — | Must | [569] |
2005 700580 | Effective date/time | — | X | — |
238000590 | Date or time or time span, value | — | X | [UB1] ∧ [495] ∧ ([130] ∨ [133]) |
2379 30300600 | CCYYMMDDHHMMZZZ | — | X | — |
| SG10.DTM | — | — | Should | [129] ∧ [569] |
2005 6000610 | Design change date | — | X | — |
238000620 | Date or time or time span, value | — | X | [931] [495] |
2379 30300630 | CCYYMMDDHHMMZZZ | — | X | — |
| SG10.STS | — | — | Should | ([92] ⊻ [93]) ∧ [126] |
9015 Z3300640 | Plausibility check note | — | X | — |
9013 Z8300650 | Customer self-reading | — | X | [5P0..1] |
9013 Z8400660 | Vacancy | — | X | [4P0..1] ⊻ [5P0..1] |
9013 Z8500670 | Actual meter overflow checked | — | X | [4P0..1] ⊻ [5P0..1] |
9013 Z8600680 | Plausible due to check reading | — | X | [4P0..1] ⊻ [5P0..1] |
9013 Z8700690 | Plausible due to customer information | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZC300700 | Exchange of the substitute value | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZS200710 | Value based on the modern measuring equipment | — | X | [4P0..1] |
| SG10.STS | — | — | Must | [92] |
9015 Z3200720 | Substitute value formation procedure | — | X | — |
9013 Z8800730 | Comparative measurement (calibrated) | — | X | [4P0..1] |
9013 Z8900740 | Comparative measurement (not calibrated) | — | X | [4P0..1] |
9013 Z9200750 | Interpolation | — | X | [4P0..1] |
9013 ZJ200760 | Statistical method | — | X | [4P0..1] |
| SG10.STS | — | — | Should | [127] ∧ [541] |
9015 Z3400770 | Reason for correction | — | X | — |
9013 Z7400780 | no access | — | X | [4P0..1] |
9013 Z7500790 | Communication fault | — | X | [4P0..1] |
9013 Z7600800 | Grid outage | — | X | [4P0..1] |
9013 Z7700810 | Voltage failure | — | X | [4P0..1] |
9013 Z7800820 | Device replacement | — | X | [4P0..1] |
9013 Z7900830 | Calibration | — | X | [4P0..1] |
9013 Z8000840 | Device operates outside the operating conditions | — | X | [4P0..1] |
9013 Z8100850 | Measuring equipment faulty/defective | — | X | [4P0..1] |
9013 Z8200860 | Measurement uncertainty | — | X | [4P0..1] |
9013 ZA000870 | Time set /synchronisation | — | X | [4P0..1] |
9013 ZA100880 | Meter reading value implausible | — | X | [4P0..1] |
9013 ZA300890 | Incorrect transformer factor | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZA400900 | Incorrect reading | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZA500910 | Change of the calculation | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZA600920 | Conversion of the metering location | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZA700930 | Data processing error | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZB000940 | Fault / defect of measuring equipment | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZB900950 | Change tariff switching times | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZC200960 | Tariff switching device defective | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZC400970 | Pulse value not sufficient | — | X | [4P0..1] |
| SG10.STS | — | — | Must | [92] |
9015 Z4000980 | Reason for substitute value formation | — | X | — |
9013 Z7400990 | no access | — | X | [4P0..1] |
9013 Z7501000 | Communication fault | — | X | [4P0..1] |
9013 Z7601010 | Grid outage | — | X | [4P0..1] |
9013 Z7701020 | Voltage failure | — | X | [4P0..1] |
9013 Z7801030 | Device replacement | — | X | [4P0..1] |
9013 Z7901040 | Calibration | — | X | [4P0..1] |
9013 Z8001050 | Device operates outside the operating conditions | — | X | [4P0..1] |
9013 Z8101060 | Measuring equipment faulty/defective | — | X | [4P0..1] |
9013 Z8201070 | Measurement uncertainty | — | X | [4P0..1] |
9013 ZA001080 | Time set /synchronisation | — | X | [4P0..1] |
9013 ZA101090 | Meter reading value implausible | — | X | [4P0..1] |
9013 ZA301100 | Incorrect transformer factor | — | X | [4P0..1] |
9013 ZA401110 | Incorrect reading | — | X | [4P0..1] |
9013 ZA501120 | Change of the calculation | — | X | [4P0..1] |
9013 ZA601130 | Conversion of the metering location | — | X | [4P0..1] |
9013 ZA701140 | Data processing error | — | X | [4P0..1] |
9013 ZB001150 | Fault / defect of measuring equipment | — | X | [4P0..1] |
9013 ZB901160 | Change tariff switching times | — | X | [4P0..1] |
9013 ZC201170 | Tariff switching device defective | — | X | [4P0..1] |
9013 ZC401180 | Pulse value not sufficient | — | X | [4P0..1] |
9013 ZT801190 | Request into the past; no value is available for the requested point in time. | — | X | [4P0..1] |
| UNT | — | — | Must | — |
007401200 | Number of segments in a message | — | X | — |
006201210 | Message reference number | — | X | — |
| UNZ | — | — | Must | — |
003601220 | Interchange counter | — | X | — |
002001230 | Interchange control reference | — | X | — |
Conditions of this table
The free text of the 38 conditions referenced by the rows above. All conditions of the message type are listed in the condition index MSCONS.
| Marker | Condition |
|---|---|
| [32] | if MP-ID in SG2 NAD+MS in the role NB |
| [35] | if MP-ID in SG2 NAD+MS in the role MSB |
| [67] | If this concerns the reference to a ORDERS |
| [77] | If MP-ID in SG2 NAD+MR of the RB HKN-R |
| [92] | If SG10 QTY DE6063 with value 67 is present |
| [93] | If SG10 QTY DE6063 with value 220 is present |
| [111] | If SG10 DTM+9 DE2379 with value 303 is present in the same segment |
| [113] | if SG7 RFF+AGK (configuration ID) is present |
| [117] | Only MP-ID from the electricity division |
| [126] | if plausibility check notices exist |
| [127] | if a correction reason has to be stated |
| [128] | If this concerns a meter reading which is not a reading due to a change to the metering equipment or its configuration (e.g. customer reading). |
| [129] | If this concerns a meter reading due to a change to the metering equipment or its configuration (e.g. device replacement). |
| [130] | If, within the same LIN segment and in addition to this segment (SG10 DTM+7 usage point in time), the SG10 DTM+60 (execution / change point in time) or the SG10 DTM+9 (reading date) is also present, the value of the difference between the later and the earlier point in time of the DTM segments may only be < 24 hours. If the summer/winter time changeover takes place between the two points in time, the value of the difference may only be < 25 hours. If the winter/summer time changeover takes place between the two points in time, the value of the difference may only be < 23 hours. |
| [131] | if RFF+AGK (configuration ID) is not present |
| [133] | If, within the same LIN segment and in addition to this segment (SG10 DTM+7 usage point in time), the SG10 DTM+9 (reading date) with the code 102 in DE2379 is also present, the value of the difference between the value at position CCYYMMDD of the later and the earlier point in time of the DTM segments at position CCYYMMDD may only be 0 or 1 day. |
| [134] | If SG10 DTM+9 DE2379 with value 102 is present in the same segment |
| [135] | The value at position CCYYMMDD must be ≤ the value at position CCYYMMDD in DE2380 of DTM+137 |
| [155] | If the transmission file is exchanged for test purposes. |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that. |
| [495] | The point in time must be ≤ the value in DE2380 of DTM+137 |
| [501] | Note: Only the values that are marked with the corresponding check identifier in the EDI@Energy code list of the OBIS codes and media are permitted. |
| [510] | Note: Use of the ID of the metering location |
| [529] | Note: Value from BGM+7 DE1004 of the ORDERS with which the request for meter reading values was made. |
| [541] | Note: A correction reason is to be specified if: 1. a preliminary value already transmitted to the MP is replaced by a substitute value after cancellation, or 2. a substitute value already transmitted to the MP is replaced by a substitute value after cancellation, or 3. a true value already transmitted to the MP is replaced by a substitute value after cancellation, or 4. a true value already transmitted to the MP is replaced by a true value after cancellation. |
| [553] | Note: Value from BGM+Z34 DE1004 of the ORDERS with which the complaint regarding values was made |
| [566] | Note: Only the values that were transmitted by the MSB in the previous master data exchange for this reporting point at the point in time are permitted. |
| [567] | Note: The configuration ID that was communicated in the previous master data exchange must be specified. |
| [569] | Note: If a metering location has several meter readings (e.g. HT/NT), this time specification is to be used and the SG9 LIN is to be repeated. |
| [902] | Format: Possible value: ≥ 0 |
| [906] | Format: max. 3 decimal places |
| [908] | Format: possible values: 1 to n |
| [918] | Format: Characters from the character set defined via UNOC, where only capital letters are permitted among the letters. |
| [931] | Format: ZZZ = +00 |
| [951] | Format: Metering point identifier |
| [UB1] | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |
| [5P0..1] | [93] If SG10 QTY DE6063 with value 220 present |
| [4P0..1] | [92] If SG10 QTY DE6063 with value 67 present |
Example message
Example 1
UNA:+.? '
UNB+UNOC:3+9907492000005:500+9904960000004:500+{{date}}:{{time}}+141757++VL'
UNH+137826+MSCONS:D:04B:UN:2.5'
BGM+7+137826BGM+9'
DTM+137:202610011100?+00:303'
RFF+Z13:13017'
NAD+MS+9907492000005::293'
NAD+MR+9904960000004::293'
UNS+D'
NAD+DP'
LOC+172+DE0073395252733953513649640711234'
RFF+MG:G12345678910'
LIN+1'
PIA+5+1-1?:1.8.0:SRW'
QTY+220:1234567.357'
DTM+9:202603011100?+00:303'
DTM+7:202603012300?+00:303'
STS+Z33++Z83'
UNT+17+137826'
UNZ+1+141757'[1 item
{6 fields
"data": {3 fields
"stammdaten": {2 fields
"ZAEHLER": [1 item
{4 fields
"ENERGIEMENGE": [1 item
{5 fields
"energieverbrauch": [1 item
{7 fields
"statuszusatzinformationen": [1 item
{2 fields
"transaktionsdaten": {11 fields
"absender": {4 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Example 2
UNA:+.? '
UNB+UNOC:3+9904446000007:500+9900321000005:500+{{date}}:{{time}}+121561++VL'
UNH+744163+MSCONS:D:04B:UN:2.5'
BGM+7+744163BGM+9'
DTM+137:202610011100?+00:303'
RFF+Z13:13017'
NAD+MS+9904446000007::293'
NAD+MR+9900321000005::293'
UNS+D'
NAD+DP'
LOC+172+DE0032106765712000000000000000037'
RFF+MG:EL001IK01013852469'
LIN+1'
PIA+5+1-0?:1.8.1:SRW'
QTY+67:1000'
DTM+7:202603252300?+00:303'
STS+Z32++Z92'
STS+Z40++Z74'
LIN+2'
PIA+5+1-0?:1.8.2:SRW'
QTY+67:11000'
DTM+7:202603252300?+00:303'
STS+Z32++Z92'
STS+Z40++Z74'
UNT+23+744163'
UNZ+1+121561'[1 item
{6 fields
"data": {3 fields
"stammdaten": {2 fields
"ZAEHLER": [1 item
{4 fields
"ENERGIEMENGE": [1 item
{6 fields
"energieverbrauch": [2 items
{6 fields
"statuszusatzinformationen": [2 items
{2 fields
{2 fields
{6 fields
"statuszusatzinformationen": [2 items
{2 fields
{2 fields
"transaktionsdaten": {11 fields
"absender": {5 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Example 3
UNA:+.? '
UNB+UNOC:3+9904446000007:500+9900051000002:500+{{date}}:{{time}}+141757++VL'
UNH+137826+MSCONS:D:04B:UN:2.5'
BGM+7+137826BGM+9'
DTM+137:202610011100?+00:303'
RFF+AGI:REF12345678910'
RFF+Z13:13017'
NAD+MS+9904446000007::293'
NAD+MR+9900051000002::293'
UNS+D'
NAD+DP'
LOC+172'
RFF+AGK:34590456ujdfsdghdlktztwqq-053trg'
LIN+1'
PIA+5+1-65?:1.8.0:SRW'
QTY+220:904'
DTM+7:202509302200?+00:303'
UNT+16+137826'
UNZ+1+141757'[1 item
{6 fields
"data": {3 fields
"stammdaten": {2 fields
"ZAEHLER": [1 item
{4 fields
"ENERGIEMENGE": [1 item
{4 fields
"energieverbrauch": [1 item
{5 fields
"transaktionsdaten": {12 fields
"absender": {5 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF, NB, MSB and ÜNB.
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Meter reading (electricity) |
| AHB | MSCONS AHB |
| Transmission channel | MP |
This check identifier is used in 11 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| Processes for the exchange of information between grid operator and the guarantee of origin register (HKN-R) of the Federal Environment Agency (UBA) | Ch. 2.3 No. 5 | NB → RB HKN-R | Response to meter reading values subscription |
| Processes for the exchange of information between grid operator and the guarantee of origin register (HKN-R) of the Federal Environment Agency (UBA) | Ch. 2.4 Case 2 No. 4 | NB → RB HKN-R | Response to meter reading values subscription |
| GPKE part 4 | Business data request | MSB → LF | Response |
| WiM electricity part 1 | Device replacement | MSB (corresponds to MSBN on the object metering location) → MSB (corresponds to MSBA on the object metering location) | Meter reading and point in time of the device removal |
| WiM electricity part 1 | Device takeover | MSB (corresponds to MSBA on the object metering location) → MSB (corresponds to MSBN on the object metering location) | Meter reading for the device takeover |
| WiM electricity part 2 | Processing and transmission of values from the MSB of the metering location | MSB (corresponds to the MSB on the object metering location) → MSB (corresponds to the MSB on the object market location) | Value (metering location) |
| WiM electricity part 2 | Processing and transmission of values from the MSB of the market location | MSB (corresponds to the MSB on the object market location) → NB | Value (market location / metering location) at NB |
| WiM electricity part 2 | Processing and transmission of values from the MSB of the market location | MSB (corresponds to the MSB on the object market location) → LF | Value (market location / metering location) at LF |
| WiM electricity part 2 | Transmission of meter readings from LF | LF → MSB (metering location) | Meter reading (metering location) |
| WiM electricity part 2 | Transmission of meter readings from NB | NB → MSB (metering location) | Meter reading (metering location) |
| GPKE part 4 | Business data request | MSB → NB | Response |
Transaction and responses
Role of this check identifier: response. Basis: the title or the action of the Prüfi table begins with “response”. The title names no polarity — whether this message confirms or rejects is decided by the response code, not by the check identifier.
Which request this message responds to
| Role | Check identifier | Use case | Message type | Origin of supply |
|---|---|---|---|---|
| Request | 17102 | Request for values | ORDERS | from the step sequence |
Forwarding (triangular communication): The preceding step holds 21010 with the same send direction. This message therefore does not answer the sender of the preceding step, it forwards — which is why there is no response sentence here.
In which field the request is quoted
| Reference field of this message | EDIFACT segment | Target field in the request |
|---|---|---|
anfrageReferenz | SG1.RFF+AGI | dokumentennummer |
RFF+AGI quotes the BGM of the request; the target is its dokumentennummer. Measured: 17102 carries dokumentennummer in BGM+[7|Z28|Z48].
Check identifiers of the same AHB table: No other check identifier of message type MSCONS has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 148 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains 3 transactions for this check identifier under the message type mscons. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.