Processing and transmission of values from the MSB of the metering location — MSB-MELO view
The MSB of the metering location transmits the processed values of the metering location to the responsible MSB of the market location. The process step applies only if one or more MSB of the metering location is/are assigned differently from the MSB of the market location. The MSB of the market location determines the values of the market location on the basis of the values of the metering location. The MSB of the market location transmits the processed values of the market location and, depending on the case, the values of the metering location to the LF, NB and ÜNB.
Process flow from the perspective of the MSB (MSB-MELO)
Process steps
Value (metering location)
MSB (corresponds to the MSB at the metering location object) MSB (corresponds to the MSB at the market location object)Check identifiers
Flow
Prozessauslöser
START_ERHEBUNG_MESSWERTEThe backend triggers this step with this event.
Load data for processing
LESEN_ENERGIEMENGE_ZAEHLERSTAND_BASIS- Read meter
GET /getCounterBasic LESEN_ENERGIEMENGE_LASTGANG_BASIS
Message to MSB (corresponds to the MSB at the market location object) · AS4
Write endpoint
- Transaction updated — Update process data
POST /updateProcessData
Updates the existing transaction in the backend once the message has been created.
- Transaction updated — Update process data
Process information
Wording of the consolidated version, profile ch. 2.4.1, pp. 19–20.
Preconditions
- The MSB knows the metering locations and market location
- The MSB knows the calculation rules for forming the values of the market location
- The MSB knows the authorised recipients of metered values
Results
- The values are available to the authorized parties on time.
- When sending corrected values, it must be checked whether documents created on the basis of the erroneous values need to be corrected.
Error case
Result in the error case
The requested values are not available to the authorized party on time.
Trigger
- A trigger named in the table „Presentation of the values to be transmitted“ exists or
- there is a need to change values as part of the processing of values or
- there is a request for values or
- there is a complaint about values.
Runs beforehand: Setup of the configurations on the basis of an assignment of a LF to a market location or tranche, Device replacement, Device takeover, Metering location change from LF to MSB, Metering location change from NB to MSB — these processes name the one shown here in their result.
First message
The party involved on this page is itself the sender of: „Value (metering location)“ to MSB (corresponds to the MSB on the market location object) (step 1).
Objective
The values have been transmitted to all authorized parties in accordance with the table „Presentation of the values to be transmitted“.
Other views of the process
The same process through the eyes of the other parties involved: the same steps, each read from their point of view.
- View MSB-MALO — MSB at the market location object · market role MSB
Notes on this page
The steps are the possible messages of this process, not a sequence — the source lists neither conditions nor alternatives. The small box on the step names the own view on the left: with ← it receives, with → it sends. Collapsed steps run between other market partners.
These read accesses are not listed in the API catalogue of this format version; the step therefore shows only their command, without address and without button.
Applies to: 1