Check identifier 17011 — Order placement quotation change of technology
Check identifier 17011 · EDIFACT message type ORDERS · Format version 202604
This page is derived from the application handbook
The MACO APP does not carry this check identifier. The complete Prüfi pages of this level are produced from the specifications of the application — one class in the templater per check identifier — and that is where the assignment to the business objects (BO4E) comes from: which object carries which field of the message.
The catalogue of the application handbook is the larger set. This page therefore shows what the handbook itself provides — use case, process context and the AHB field list with its conditions. A data structure according to BO4E is not shown, and not because there is none, but because the application does not form one for this check identifier.
All check identifiers in this situation — and the corresponding figures — are listed by the overview of this version.
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 17011 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 ORDERS00020 | Order placement | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 09B00040 | Edition 2009 - B | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 1.4b00060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 Z1200070 | Change of the technology of the location | — | X | [592] |
1001 Z9300080 | Order placement for an offer for a change of the technology of the location | — | X | [591] |
100400090 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700100 | Document-/message date/time | — | X | — |
238000110 | Date or time or time span, value | — | X | [931] [494] |
2379 30300120 | CCYYMMDDHHMMZZZ | — | X | — |
| DTM | — | — | Must | [182] |
2005 20300130 | Execution date/time | — | X | — |
238000140 | Date or time or time span, value | — | X | [UB1] |
2379 30300150 | CCYYMMDDHHMMZZZ | — | X | — |
| DTM | — | — | Must | [181] |
2005 46900160 | Start date or point in time, earliest | — | X | — |
238000170 | Date or time or time span, value | — | X | [UB1] [579] |
2379 30300180 | CCYYMMDDHHMMZZZ | — | X | — |
| DTM | — | — | Must | [181] |
2005 47200190 | End date or time, latest | — | X | — |
238000200 | Date or time or time span, value | — | X | [UB1] [580] |
2379 30300210 | CCYYMMDDHHMMZZZ | — | X | — |
| SG1.RFF | — | — | Must | — |
1153 ACW00220 | Reference number of a preceding message | — | X | — |
115400230 | Message number | — | X | [578] |
| SG1.RFF | — | — | Must | — |
1153 AAG00240 | Quotation number | — | X | — |
115400250 | Message number | — | X | [577] |
| SG1.RFF | — | — | Must | — |
1153 Z1300260 | Check identifier | — | X | — |
1154 1701100270 | Order placement for an offer for a change of technology | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00280 | Document-/message sender or sender | — | X | — |
303900290 | MP-ID | — | X | [61] |
3055 900300 | GS1 | — | X | — |
3055 29300310 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG5.CTA | — | — | Must | — |
3139 IC00320 | Information contact | — | X | — |
341200330 | Contact | — | X | — |
| SG5.COM | — | — | Must | — |
314800340 | Communication address, identification | — | X | (([939] [147]) ∨ ([940] [148])) ∧ [567] |
3155 EM00350 | Electronic mail | — | X | [1P0..1] |
3155 FX00360 | Fax number | — | X | [1P0..1] |
3155 TE00370 | Telephone | — | X | [1P0..1] |
3155 AJ00380 | further telephone | — | X | [1P0..1] |
3155 AL00390 | Mobile phone | — | X | [1P0..1] |
| SG2.NAD | — | — | Must | — |
3035 MR00400 | Message recipient | — | X | — |
303900410 | MP-ID | — | X | [61] |
3055 900420 | GS1 | — | X | — |
3055 29300430 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 DP00440 | Supply address | — | X | — |
| SG2.LOC | — | — | Must | — |
3227 17200450 | Reporting point | — | X | — |
322500460 | Identifier | — | X | ([951] [522]) ⊻ ([961] [553]) ⊻ ([960] [552]) |
| SG3.RFF | — | — | Must | — |
1153 Z1800470 | Market location | — | X | — |
115400480 | ID of the market location | — | X | [950] [521] |
| SG3.RFF | — | — | Must | — |
1153 Z3700490 | Technical resource | — | X | — |
115400500 | ID of the technical resource | — | X | [922] [566] |
| SG2.NAD | — | — | Must | — |
3035 Z0900510 | Customer of the LF | — | X | — |
| SG5.CTA | — | — | Must | — |
3139 IC00520 | Information point | — | X | — |
341200530 | Contact | — | X | — |
| SG5.COM | — | — | Must | — |
314800540 | Communication address, identification | — | X | (([939] [147]) ∨ ([940] [148])) ∧ [567] |
3155 EM00550 | — | X | [1P0..1] | |
3155 FX00560 | Fax number | — | X | [1P0..1] |
3155 TE00570 | Telephone | — | X | [1P0..1] |
3155 AJ00580 | further telephone | — | X | [1P0..1] |
3155 AL00590 | Mobile phone | — | X | [1P0..1] |
| SG2.NAD | — | — | Must | [571] |
3035 DEB00600 | Metering point operator | — | X | — |
303900610 | MP-ID | — | X | [61] |
3055 900620 | GS1 | — | X | — |
3055 29300630 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG29.LIN | — | — | Must | — |
108200640 | Line item number | — | X | [911] |
1229 Z1900650 | Required product of the metering location | — | X | — |
| SG29.PIA | — | — | Must | — |
4347 500660 | Product identification | — | X | — |
714000670 | Product code | — | X | [153] ∧ (([6] ∧ [157]) ⊻ ([7] ∧ [156])) |
7143 Z1100680 | Product | — | X | — |
| SG29.LIN | — | — | Must | — |
108200690 | Line item number | — | X | [911] |
1229 Z5500700 | Required product of the grid location | — | X | — |
| SG29.PIA | — | — | Must | — |
4347 500710 | Product identification | — | X | — |
714000720 | Product code | — | X | [154] ∧ (([6] ∧ [157]) ⊻ ([7] ∧ [156])) |
7143 Z1100730 | Product | — | X | — |
| SG29.LIN | — | — | Must | — |
108200740 | Line item number | — | X | [911] |
1229 Z5600750 | Required product of the controllable resource | — | X | — |
| SG29.PIA | — | — | Must | — |
4347 500760 | Product identification | — | X | — |
714000770 | Product code | — | X | [155] ∧ (([6] ∧ [157]) ⊻ ([7] ∧ [156])) |
7143 Z1100780 | Product | — | X | — |
| UNS | — | — | Must | — |
0081 S00790 | Separation of detail and summary section | — | X | — |
| UNT | — | — | Must | — |
007400800 | Number of segments in a message | — | X | — |
006200810 | Message reference number | — | X | — |
Conditions of this table
The free text of the 37 conditions referenced by the rows above. All conditions of the message type are listed in the condition index ORDERS.
| Marker | Condition |
|---|---|
| [6] | If MP-ID in SG2 NAD+MS with role LF is present |
| [7] | If MP-ID in SG2 NAD+MS with role NB is present |
| [61] | MP-ID only from division electricity |
| [147] | if the code EM is present in DE3155 in the same COM |
| [148] | if the code TE / FX / AJ / AL is present in DE3155 in the same COM |
| [153] | Only the product codes are permitted that are present with the value "Metering location" in the column "Level" in chapter 7 "Products for the order placement of a change at a location" of the code list of configurations. |
| [154] | Only the product codes are permitted that are present with the value "Grid location" in the column "Level" in chapter 7 "Products for the order placement of a change at a location" of the code list of configurations. |
| [155] | Only the product codes are permitted that are present with the value "Controllable resource" in the column "Level" in chapter 7 "Products for the order placement of a change at a location" of the code list of configurations. |
| [156] | Furthermore, only the product codes are permitted that are marked with an "X" in the column "NB" within the column "Product orderable from MSB by market role" in chapter 7 "Products for the order placement of a change at a location" of the code list of configurations. |
| [157] | Furthermore, only the product codes are permitted that are marked with an "X" in the column "LF" within the column "Product orderable from MSB by market role" in chapter 7 "Products for the order placement of a change at a location" of the code list of configurations. |
| [181] | If BGM+Z93 (order placement for an offer for change of the technology of the location) present |
| [182] | If BGM+Z12 (change of the technology of the location) present. |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that. |
| [521] | Note: Use of the ID of the market location |
| [522] | Note: Use of the ID of the metering location |
| [552] | Note: Use of the ID of the grid location |
| [553] | Note: Use of the ID of the controllable resource |
| [566] | Note: Use of the ID of the technical resource |
| [567] | Note: Only one piece of information may be transmitted in DE3148 |
| [571] | Note: MSB of the market location to which the values of the further energy flow direction of the metering location are to be transmitted. |
| [577] | Note: Value from BGM+Z93 (order placement for a quotation for the change of the technology of the location) DE1004 of the QUOTES with which the quotation was made. |
| [578] | Note: Value from BGM DE1004 of the PRICAT with which price sheet B of the MSB on which the quotation is based from the point of view of the NB was transmitted. |
| [579] | Note: Statement of the start point in time of the desired implementation date from the ordering party's point of view. |
| [580] | Note: Indication of the end point in time of the desired implementation date from the orderer's perspective. |
| [591] | Note: If this concerns the order placement of a previous quotation within the scope of the BDEW application guide "Processes for changing the technology at locations". |
| [592] | Note: if this concerns the order issuance of a change in accordance with WiM Part 1 UC "Change of metering location". |
| [911] | Format: Possible values: 1 to n, starting at 1 for each message or segment group and ascending consecutively |
| [922] | Format: TR-ID |
| [931] | Format: ZZZ = +00 |
| [939] | Format: the character string must contain the characters @ and . |
| [940] | Format: the character string must begin with the character + and may only be followed by digits |
| [950] | Format: market location ID |
| [951] | Format: Metering point identifier |
| [960] | Format: Grid location ID |
| [961] | Format: SR-ID |
| [UB1] | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF, NB and MSB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | Metering location change from the LF to MSB | AWH processes for changing the technology at locations | Electricity | Step 3 |
| LF | LF | Metering location change from the LF to MSB | WiM electricity part 1 | Electricity | Step 1 |
| NB | NB | Metering location change from the NB to MSB | AWH processes for changing the technology at locations | Electricity | Step 3 |
| NB | NB | Metering location change from the NB to MSB | WiM electricity part 1 | Electricity | Step 1 |
| MSB | MSB-MELO | Metering location change from the LF to MSB | AWH processes for changing the technology at locations | Electricity | Step 3 |
| MSB | MSB-MELO | Metering location change from the NB to MSB | AWH processes for changing the technology at locations | Electricity | Step 3 |
| MSB | MSB-MELO | Metering location change from the LF to MSB | WiM electricity part 1 | Electricity | Step 1 |
| MSB | MSB-MELO | Metering location change from the NB to MSB | WiM electricity part 1 | Electricity | Step 1 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Order placement quotation change of technology |
| AHB | ORDERS AHB |
| Transmission channel | AS4 |
This check identifier is used in 4 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| WiM electricity part 1 | Metering location change from NB to MSB | NB → MSB (corresponds to MSB on the metering location object) | Order issuance change |
| WiM electricity part 1 | Metering location change from LF to MSB | LF → MSB (corresponds to MSB on the metering location object) | Order issuance change |
| AWH processes for changing the technology at locations | Metering location change from NB to MSB | NB → MSB (corresponds to MSB on the metering location object) | Order placement |
| AWH processes for changing the technology at locations | Metering location change from LF to MSB | LF → MSB (corresponds to MSB on the metering location object) | Order placement |
Notes on this page
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 110 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.