Check identifier 17008 — Order cancellation for values
Check identifier 17008 · EDIFACT message type ORDERS · Format version 202610
This page is derived from the application handbook
The MACO APP does not carry this check identifier. The complete Prüfi pages of this level are produced from the specifications of the application — one class in the templater per check identifier — and that is where the assignment to the business objects (BO4E) comes from: which object carries which field of the message.
The catalogue of the application handbook is the larger set. This page therefore shows what the handbook itself provides — use case, process context and the AHB field list with its conditions. A data structure according to BO4E is not shown, and not because there is none, but because the application does not form one for this check identifier.
All check identifiers in this situation — and the corresponding figures — are listed by the overview of this version.
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 17008 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 ORDERS00020 | Order placement | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 09B00040 | Edition 2009 - B | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 1.4c00060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 Z5700070 | Transmission of values to ESA | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| DTM | — | — | Must | — |
2005 20300120 | Execution date/time | — | X | — |
238000130 | Date or time or time span, value | — | X | [UB1] |
2379 30300140 | CCYYMMDDHHMMZZZ | — | X | — |
| IMD | — | — | Must | — |
7081 Z0200150 | End of subscription | — | X | — |
| SG1.RFF | — | — | Must | — |
1153 ACW00160 | Reference number of a preceding message | — | X | — |
115400170 | Message number | — | X | [543] |
| SG1.RFF | — | — | Must | — |
1153 Z1300180 | Check identifier | — | X | — |
1154 1700800190 | Order cancellation of values for ESA | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00200 | Document-/message sender or sender | — | X | — |
303900210 | MP-ID | — | X | [61] |
3055 900220 | GS1 | — | X | — |
3055 29300230 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MR00240 | Message recipient | — | X | — |
303900250 | MP-ID | — | X | [61] |
3055 900260 | GS1 | — | X | — |
3055 29300270 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| UNS | — | — | Must | — |
0081 S00280 | Separation of detail and summary section | — | X | — |
| UNT | — | — | Must | — |
007400290 | Number of segments in a message | — | X | — |
006200300 | Message reference number | — | X | — |
Conditions of this table
The free text of the 5 conditions referenced by the rows above. All conditions of the message type are listed in the condition index ORDERS.
| Marker | Condition |
|---|---|
| [61] | MP-ID only from division electricity |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that. |
| [543] | Note: Value from BGM+Z57 DE1004 of the ORDERS with which the order placement for the values was made. |
| [931] | Format: ZZZ = +00 |
| [UB1] | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are MSB and ESA.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| MSB | MSB | Termination of the transmission of values to ESA by ESA | WiM electricity part 2 | Electricity | Step 1 |
| ESA | ESA | Termination of the transmission of values to ESA by ESA | WiM electricity part 2 | Electricity | Step 1 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Order cancellation of values |
| AHB | ORDERS AHB |
| Transmission channel | AS4 |
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| WiM electricity part 2 | Termination of the transmission of values to ESA by ESA | ESA → MSB | Termination of the transmission of values |
Notes on this page
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 41 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.