Check identifier 17117 — Reconnection order
Check identifier 17117 · EDIFACT message type ORDERS · Format version 202610
Data structure
| Structure (BO4E) | Description | Format | 17117 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| ANFRAGE [ ] * | — | object[] | Must | — |
| anfragetyp * 00010 | Type/kind of the request (ORDERS ORDRSP IMD 7081) | Enum Anfragetyp | Must | — |
KAUF | — | — | Must | — |
NUTZUNGSUEBERLASSUNG | — | — | Must | — |
ABRECHNUNGSBRENNWERT_UND_ZUSTANDSZAHL | — | — | Must | — |
LASTGANGDATEN | — | — | Must | — |
ZAEHLERSTAENDE | — | — | Must | — |
WERTEERMITTLUNG | — | — | Must | — |
ENERGIEMENGE_EINZELWERT | — | — | Must | — |
INNERHALB_DER_ARBEITSZEIT | — | — | Must | — |
AUCH_AUSSERHALB_DER_ARBEITSZEIT | — | — | Must | — |
WECHSEL_SAEMTLICHER_EINRICHTUNGEN | — | — | Must | — |
TEILWEISER_WECHSEL | — | — | Must | — |
AENDERUNG_ZAEHLZEITDEFINITION | — | — | Must | — |
ABBESTELLUNG_ZAEHLZEITEN | — | — | Must | — |
ABBESTELLUNG_MESSPRODUKT | — | — | Must | — |
ANGEBOT_AUF_BASIS_PREISBLATT | — | — | Must | — |
INDIVIDUELLES_ANGEBOT | — | — | Must | — |
AENDERUNG_KONFIGURATION | — | — | Must | — |
KANN_NICHT_ANGEBOTEN_WERDEN | — | — | Must | — |
NEUKONFIGURATION | — | — | Must | — |
BEENDIGUNG_KONFIGURATION | — | — | Must | — |
AKTIVIERUNG_KONFIGURATION | — | — | Must | — |
| lokationsId * 00020 | Which market or metering location this request applies to. | string | X | — |
| AUFTRAG [ ] | — | object[] | May | — |
| positionsdaten [ ] | — | object[] | May | — |
| allgemeineInformationen | — | object | May | — |
| info1 00030 | General info 1 | string | X | — |
| info2 00040 | General info 2 | string | X | — |
| info3 00050 | General info 3 | string | X | — |
| info4 00060 | General info 4 | string | X | — |
| info5 00070 | General info 5 | string | X | — |
| SPERRAUFTRAG [ ] | — | object[] | May | — |
| treffpunkt | — | object | May | — |
| hausnummer 00080 | House number and supplement | string | X | — |
| landescode 00090 | Country code | Enum Landescode | X | — |
AC | — | — | X | — |
AD | — | — | X | — |
AE | — | — | X | — |
AF | — | — | X | — |
AG | — | — | X | — |
AI | — | — | X | — |
AL | — | — | X | — |
AM | — | — | X | — |
AN | — | — | X | — |
AO | — | — | X | — |
AQ | — | — | X | — |
AR | — | — | X | — |
AS | — | — | X | — |
AT | — | — | X | — |
AU | — | — | X | — |
AW | — | — | X | — |
AX | — | — | X | — |
AZ | — | — | X | — |
BA | — | — | X | — |
BB | — | — | X | — |
BD | — | — | X | — |
BE | — | — | X | — |
BF | — | — | X | — |
BG | — | — | X | — |
BH | — | — | X | — |
BI | — | — | X | — |
BJ | — | — | X | — |
BL | — | — | X | — |
BM | — | — | X | — |
BN | — | — | X | — |
BO | — | — | X | — |
BQ | — | — | X | — |
BR | — | — | X | — |
BS | — | — | X | — |
BT | — | — | X | — |
BU | — | — | X | — |
BV | — | — | X | — |
BW | — | — | X | — |
BY | — | — | X | — |
BZ | — | — | X | — |
CA | — | — | X | — |
CC | — | — | X | — |
CD | — | — | X | — |
CF | — | — | X | — |
CG | — | — | X | — |
CH | — | — | X | — |
CI | — | — | X | — |
CK | — | — | X | — |
CL | — | — | X | — |
CM | — | — | X | — |
CN | — | — | X | — |
CO | — | — | X | — |
CP | — | — | X | — |
CR | — | — | X | — |
CS | — | — | X | — |
CU | — | — | X | — |
CV | — | — | X | — |
CW | — | — | X | — |
CX | — | — | X | — |
CY | — | — | X | — |
CZ | — | — | X | — |
DE | — | — | X | — |
DG | — | — | X | — |
DJ | — | — | X | — |
DK | — | — | X | — |
DM | — | — | X | — |
DO | — | — | X | — |
DZ | — | — | X | — |
EA | — | — | X | — |
EC | — | — | X | — |
EE | — | — | X | — |
EG | — | — | X | — |
EH | — | — | X | — |
ER | — | — | X | — |
ES | — | — | X | — |
ET | — | — | X | — |
EU | — | — | X | — |
FI | — | — | X | — |
FJ | — | — | X | — |
FK | — | — | X | — |
FM | — | — | X | — |
FO | — | — | X | — |
FR | — | — | X | — |
FX | — | — | X | — |
GA | — | — | X | — |
GB | — | — | X | — |
GD | — | — | X | — |
GE | — | — | X | — |
GF | — | — | X | — |
GG | — | — | X | — |
GH | — | — | X | — |
GI | — | — | X | — |
GL | — | — | X | — |
GM | — | — | X | — |
GN | — | — | X | — |
GP | — | — | X | — |
GQ | — | — | X | — |
GR | — | — | X | — |
GS | — | — | X | — |
GT | — | — | X | — |
GU | — | — | X | — |
GW | — | — | X | — |
GY | — | — | X | — |
HK | — | — | X | — |
HM | — | — | X | — |
HN | — | — | X | — |
HR | — | — | X | — |
HT | — | — | X | — |
HU | — | — | X | — |
IC | — | — | X | — |
ID | — | — | X | — |
IE | — | — | X | — |
IL | — | — | X | — |
IM | — | — | X | — |
IN | — | — | X | — |
IO | — | — | X | — |
IQ | — | — | X | — |
IR | — | — | X | — |
IS | — | — | X | — |
IT | — | — | X | — |
JE | — | — | X | — |
JM | — | — | X | — |
JO | — | — | X | — |
JP | — | — | X | — |
KE | — | — | X | — |
KG | — | — | X | — |
KH | — | — | X | — |
KI | — | — | X | — |
KM | — | — | X | — |
KN | — | — | X | — |
KP | — | — | X | — |
KR | — | — | X | — |
KW | — | — | X | — |
KY | — | — | X | — |
KZ | — | — | X | — |
LA | — | — | X | — |
LB | — | — | X | — |
LC | — | — | X | — |
LI | — | — | X | — |
LK | — | — | X | — |
LR | — | — | X | — |
LS | — | — | X | — |
LT | — | — | X | — |
LU | — | — | X | — |
LV | — | — | X | — |
LY | — | — | X | — |
MA | — | — | X | — |
MC | — | — | X | — |
MD | — | — | X | — |
ME | — | — | X | — |
MF | — | — | X | — |
MG | — | — | X | — |
MH | — | — | X | — |
MK | — | — | X | — |
ML | — | — | X | — |
MM | — | — | X | — |
MN | — | — | X | — |
MO | — | — | X | — |
MP | — | — | X | — |
MQ | — | — | X | — |
MR | — | — | X | — |
MS | — | — | X | — |
MT | — | — | X | — |
MU | — | — | X | — |
MV | — | — | X | — |
MW | — | — | X | — |
MX | — | — | X | — |
MY | — | — | X | — |
MZ | — | — | X | — |
NA | — | — | X | — |
NC | — | — | X | — |
NE | — | — | X | — |
NF | — | — | X | — |
NG | — | — | X | — |
NI | — | — | X | — |
NL | — | — | X | — |
NO | — | — | X | — |
NP | — | — | X | — |
NR | — | — | X | — |
NT | — | — | X | — |
NU | — | — | X | — |
NZ | — | — | X | — |
OM | — | — | X | — |
PA | — | — | X | — |
PE | — | — | X | — |
PF | — | — | X | — |
PG | — | — | X | — |
PH | — | — | X | — |
PK | — | — | X | — |
PL | — | — | X | — |
PM | — | — | X | — |
PN | — | — | X | — |
PR | — | — | X | — |
PS | — | — | X | — |
PT | — | — | X | — |
PW | — | — | X | — |
PY | — | — | X | — |
QA | — | — | X | — |
RE | — | — | X | — |
RO | — | — | X | — |
RS | — | — | X | — |
RU | — | — | X | — |
RW | — | — | X | — |
SA | — | — | X | — |
SB | — | — | X | — |
SC | — | — | X | — |
SD | — | — | X | — |
SE | — | — | X | — |
SF | — | — | X | — |
SG | — | — | X | — |
SH | — | — | X | — |
SI | — | — | X | — |
SJ | — | — | X | — |
SK | — | — | X | — |
SL | — | — | X | — |
SM | — | — | X | — |
SN | — | — | X | — |
SO | — | — | X | — |
SR | — | — | X | — |
SS | — | — | X | — |
ST | — | — | X | — |
SU | — | — | X | — |
SV | — | — | X | — |
SX | — | — | X | — |
SY | — | — | X | — |
SZ | — | — | X | — |
TA | — | — | X | — |
TC | — | — | X | — |
TD | — | — | X | — |
TF | — | — | X | — |
TG | — | — | X | — |
TJ | — | — | X | — |
TK | — | — | X | — |
TL | — | — | X | — |
TM | — | — | X | — |
TN | — | — | X | — |
TO | — | — | X | — |
TP | — | — | X | — |
TR | — | — | X | — |
TT | — | — | X | — |
TV | — | — | X | — |
TW | — | — | X | — |
TZ | — | — | X | — |
UA | — | — | X | — |
UG | — | — | X | — |
UK | — | — | X | — |
UM | — | — | X | — |
US | — | — | X | — |
UY | — | — | X | — |
UZ | — | — | X | — |
VA | — | — | X | — |
VC | — | — | X | — |
VE | — | — | X | — |
VG | — | — | X | — |
VI | — | — | X | — |
VN | — | — | X | — |
VU | — | — | X | — |
WF | — | — | X | — |
WS | — | — | X | — |
XK | — | — | X | — |
YE | — | — | X | — |
YT | — | — | X | — |
YU | — | — | X | — |
ZA | — | — | X | — |
ZM | — | — | X | — |
ZR | — | — | X | — |
ZW | — | — | X | — |
| ort 00100 | City | string | X | — |
| ortsteil 00110 | District | string | X | — |
| postfach 00120 | PO box | string | X | — |
| postleitzahl 00130 | Postal code | string | X | — |
| strasse 00140 | Street | string | X | — |
| zusatzInformation | — | object | May | — |
| zusatz1 00150 | Address supplement 1 | string | X | — |
| zusatz2 00160 | Address supplement 2 | string | X | — |
| zusatz3 00170 | Address supplement 3 | string | X | — |
| zusatz4 00180 | Address supplement 4 | string | X | — |
| zusatz5 00190 | Address supplement 5 | string | X | — |
| transaktionsdaten * | — | object | Must | — |
| dokumentennummer * 00200 | EDIFACT reference from the BGM segment / BGM | string | X | — |
| nachrichtendatum * 00210 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenreferenznummer * 00220 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 00230 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 00240 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00250 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| ansprechpartner * | — | object | Must | — |
| eMailAdresse 00260 | Email address | string | Must | — |
| nachname * 00270 | Surname (family name) of the contact person | string | X | — |
| rufnummern [ ] | — | object[] | May | — |
| nummerntyp 00280 | Phone number type | Enum Rufnummernart | Must | — |
RUF_ZENTRALE | — | — | Must | — |
FAX_ZENTRALE | — | — | Must | — |
SAMMELRUF | — | — | Must | — |
SAMMELFAX | — | — | Must | — |
ABTEILUNGRUF | — | — | Must | — |
ABTEILUNGFAX | — | — | Must | — |
RUF_DURCHWAHL | — | — | Must | — |
FAX_DURCHWAHL | — | — | Must | — |
MOBIL_NUMMER | — | — | Must | — |
| rufnummer 00290 | rufnummer | string | Must | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 00300 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00310 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 17117 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 ORDERS00020 | Order placement | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 09B00040 | Edition 2009 - B | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 1.4c00060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 Z5200070 | Reconnection | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| IMD | — | — | Must | — |
7081 Z5300120 | within working hours | — | X | — |
7081 Z5400130 | also outside working hours | — | X | — |
| SG1.RFF | — | — | Must | — |
1153 Z1300140 | Check identifier | — | X | — |
1154 1711700150 | Reconnection order | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00160 | Document-/message sender or sender | — | X | — |
303900170 | MP-ID | — | X | — |
3055 900180 | GS1 | — | X | — |
3055 29300190 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
3055 33200200 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG5.CTA | — | — | Must | — |
3139 IC00210 | Information contact | — | X | — |
341200220 | Contact | — | X | — |
| SG5.COM | — | — | Must | — |
314800230 | Communication address, identification | — | X | (([939] [147]) ⊻ ([940] [148])) ∧ [567] |
3155 EM00240 | Electronic mail | — | X | [1P0..1] |
3155 FX00250 | Fax number | — | X | [1P0..1] |
3155 TE00260 | Telephone | — | X | [1P0..1] |
3155 AJ00270 | further telephone | — | X | [1P0..1] |
3155 AL00280 | Mobile phone | — | X | [1P0..1] |
| SG2.NAD | — | — | Must | — |
3035 MR00290 | Message recipient | — | X | — |
303900300 | MP-ID | — | X | — |
3055 900310 | GS1 | — | X | — |
3055 29300320 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
3055 33200330 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 DP00340 | Supply address | — | X | — |
| SG2.LOC | — | — | Must | — |
3227 17200350 | Reporting point | — | X | — |
322500360 | Identifier | — | X | [950] [521] |
| SG2.NAD | — | — | Must | — |
3035 Z2400370 | Meeting point | — | X | — |
312400380 | Additional information for identification | — | — | — |
304200390 | Street and house number or PO box | — | — | M [57] |
316400400 | City | — | X | — |
325100410 | Postal code, code | — | X | — |
320700420 | Country name, code | — | X | — |
| SG29.LIN | — | — | Must | — |
108200430 | Line item number | — | X | [903] |
| SG29.FTX | — | — | May | — |
4451 ACB00440 | Additional information (for general notes) | — | X | — |
444000450 | Free text | — | X | — |
| UNS | — | — | Must | — |
0081 S00460 | Separation of detail and summary section | — | X | — |
| UNT | — | — | Must | — |
007400470 | Number of segments in a message | — | X | — |
006200480 | Message reference number | — | X | — |
Conditions of this table
The free text of the 12 conditions referenced by the rows above. All conditions of the message type are listed in the condition index ORDERS.
| Marker | Condition |
|---|---|
| [57] | If NAD DE3124 is not present in the same SG2 |
| [147] | If code EM is present in DE3155 in the same COM |
| [148] | If code TE / FX / AJ / AL is present in DE3155 in the same COM |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that. |
| [521] | Note: Use of the ID of the market location |
| [567] | Note: Only one piece of information may be transmitted in DE3148 |
| [903] | Format: Possible value: 1 |
| [931] | Format: ZZZ = +00 |
| [939] | Format: the character string must contain the characters @ and . |
| [940] | Format: the character string must begin with the character + and may only be followed by digits |
| [950] | Format: market location ID |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
Example message
UNA:+.? '
UNB+UNOC:3+9903111000003:500+9900259000002:500+{{date}}:{{time}}+M06ORI2R'
UNH+M0WCBIHV+ORDERS:D:09B:UN:1.4c'
BGM+Z52+M012WJWI'
DTM+137:202610011100?+00:303'
IMD++Z54'
RFF+Z13:17117'
NAD+MS+9903111000003::293'
CTA+IC+:Laue'
COM+a.laue@conuti.de:EM'
NAD+MR+9900259000002::293'
NAD+DP'
LOC+172+44897654121'
NAD+Z24++++Lohbacherstraße 30+Velbert++42553+DE'
UNS+S'
UNT+14+M0WCBIHV'
UNZ+1+M06ORI2R'[1 item
{6 fields
"data": {3 fields
"stammdaten": {2 fields
"ANFRAGE": [1 item
{6 fields
"SPERRAUFTRAG": [1 item
{3 fields
"treffpunkt": {4 fields
"transaktionsdaten": {8 fields
"absender": {5 fields
"ansprechpartner": {4 fields
"empfaenger": {4 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF, NB, MSB and ÜNB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | Restoration of grid connection use (reconnect) on instruction of the LF | AWH disconnection processes gas | Gas | Step 1 |
| LF | LF | Restoration of grid connection use (reconnect) on instruction of the LF | GPKE part 2 | Electricity | Step 1 |
| NB | NB | Restoration of grid connection use (reconnect) on instruction of the LF | AWH disconnection processes gas | Gas | Step 1 |
| NB | NB | Restoration of grid connection use (reconnect) on instruction of the LF | GPKE part 2 | Electricity | Step 1 |
| MSB | MSB | Restoration of grid connection use (reconnect) on instruction of the LF | AWH disconnection processes gas | Gas | Step 1 |
| MSB | MSB | Restoration of grid connection use (reconnect) on instruction of the LF | GPKE part 2 | Electricity | Step 1 |
| ÜNB | ÜNB | Restoration of grid connection use (reconnect) on instruction of the LF | GPKE part 2 | Electricity | Step 1 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Reconnection order |
| AHB | ORDERS AHB |
| Transmission channel | AS4 |
This check identifier is used in 3 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| AWH disconnection processes gas | Restoration of grid connection use (reconnect) on instruction from the LF | LF → NB | Reconnection order |
| GPKE part 2 | Restoration of grid connection use (reconnect) on instruction from the LF | LF → NB | Reconnection order |
| Application guide for gas disconnection processes | Restoration of grid connection use (reconnect) on instruction from the LF | LF → NB | Reconnection order |
Transaction and responses
Role of this check identifier: request. Basis: the transaction data carry neither antwortstatus nor antwortstatusCodeliste, and neither the title nor the action of the Prüfi table begins with “response” or “response message”.
Which messages respond to this
| Role | Check identifier | Use case | Message type | Origin of supply |
|---|---|---|---|---|
| Response | 19116 | Confirmation of disconnection/reconnection order | ORDRSP | from the step sequence |
| Response | 19117 | Rejection disconnection/reconnection order | ORDRSP | from the step sequence |
This column is the inverse of the assignment on the response pages — not the next step of a list. The process source says of its own steps that they are »possible messages, not a sequence«.
Check identifiers of the same AHB table: No other check identifier of message type ORDERS has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 64 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains one transaction for this check identifier under the message type orders. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.