Check identifier 17006 — Termination of invoice processing MSB via LF
Check identifier 17006 · EDIFACT message type ORDERS · Format version 202604
Data structure
| Structure (BO4E) | Description | Format | 17006 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| ANFRAGE [ ] * | — | object[] | Must | — |
| abonnement * 00010 | Start or end of subscription | Enum Abonnement | Must | — |
START_ABO | — | — | Must | — |
ENDE_ABO | — | — | Must | — |
OHNE_ABO | — | — | Must | — |
| lokationsId * 00020 | Which market or metering location this request applies to. | string | X | — |
| AUFTRAG [ ] * | — | object[] | Must | — |
| ausfuehrungsdatum * 00030 | The execution date describes at which point in time an order is to be executed. | string (date-time) | X | — |
| positionsdaten [ ] | — | object[] | May | — |
| anfragegrund 00040 | Request reason | Enum Anfragegrund | Must | — |
ABGRENZUNG_VON_ENERGIEMENGEN | — | — | Must | — |
ABGRENZUNG | — | — | Must | — |
WECHSELEREIGNIS | — | — | Must | — |
ZWISCHENABLESUNG | — | — | Must | — |
DIREKTER_VERTRAG_MSB_AN | — | — | Must | — |
DIREKTER_VERTRAG_MSB_ANN | — | — | Must | — |
AENDERUNG_IM_LOKATIONSBUENDEL | — | — | Must | — |
NEUKONFIGURATION | — | — | Must | — |
KONFIGURATION_UNVERAENDERT | — | — | Must | — |
| transaktionsdaten * | — | object | Must | — |
| dokumentennummer * 00050 | EDIFACT reference from the BGM segment / BGM | string | X | — |
| nachrichtendatum * 00060 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenreferenznummer * 00070 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 00080 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 00090 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00100 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| ansprechpartner | — | object | May | — |
| eMailAdresse 00110 | Email address | string | Must | — |
| nachname 00120 | Surname (family name) of the contact person | string | X | — |
| rufnummern [ ] | — | object[] | May | — |
| nummerntyp 00130 | Phone number type | Enum Rufnummernart | Must | — |
RUF_ZENTRALE | — | — | Must | — |
FAX_ZENTRALE | — | — | Must | — |
SAMMELRUF | — | — | Must | — |
SAMMELFAX | — | — | Must | — |
ABTEILUNGRUF | — | — | Must | — |
ABTEILUNGFAX | — | — | Must | — |
RUF_DURCHWAHL | — | — | Must | — |
FAX_DURCHWAHL | — | — | Must | — |
MOBIL_NUMMER | — | — | Must | — |
| rufnummer 00140 | rufnummer | string | Must | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 00150 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00160 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 17006 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 ORDERS00020 | Order placement | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 09B00040 | Edition 2009 - B | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 1.4b00060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 Z2900070 | Billing of metering point operation from the MSB to the LF | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| DTM | — | — | Must | — |
2005 20300120 | Execution date/time | — | X | — |
238000130 | Date or time or time span, value | — | X | [UB1] ∧ [518] |
2379 30300140 | CCYYMMDDHHMMZZZ | — | X | — |
| IMD | — | — | Must | — |
7081 Z0200150 | End of subscription | — | X | — |
| SG1.RFF | — | — | Must | — |
1153 Z1300160 | Check identifier | — | X | — |
1154 1700600170 | Termination of invoice processing MSB via LF | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00180 | Document-/message sender or sender | — | X | — |
303900190 | MP-ID | — | X | [61] |
3055 900200 | GS1 | — | X | — |
3055 29300210 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG5.CTA | — | — | Must | — |
3139 IC00220 | Information contact | — | X | — |
341200230 | Contact | — | X | — |
| SG5.COM | — | — | Must | — |
314800240 | Communication address, identification | — | X | (([939] [147]) ∨ ([940] [148])) ∧ [567] |
3155 EM00250 | Electronic mail | — | X | [1P0..1] |
3155 FX00260 | Fax number | — | X | [1P0..1] |
3155 TE00270 | Telephone | — | X | [1P0..1] |
3155 AJ00280 | further telephone | — | X | [1P0..1] |
3155 AL00290 | Mobile phone | — | X | [1P0..1] |
| SG2.NAD | — | — | Must | — |
3035 MR00300 | Message recipient | — | X | — |
303900310 | MP-ID | — | X | [61] |
3055 900320 | GS1 | — | X | — |
3055 29300330 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 DP00340 | Supply address | — | X | — |
| SG2.LOC | — | — | Must | — |
3227 17200350 | Reporting point | — | X | — |
322500360 | Identifier | — | X | [950] [521] |
| SG29.LIN | — | — | Must | — |
108200370 | Line item number | — | X | [903] |
| SG29.IMD | — | — | Must | — |
7081 Z6100380 | Direct contract MSB - AN | — | X | — |
7081 Z6200390 | Direct contract MSB - ANN | — | X | — |
7081 Z6300400 | Change in the location bundle | — | X | — |
| UNS | — | — | Must | — |
0081 S00410 | Separation of detail and summary section | — | X | — |
| UNT | — | — | Must | — |
007400420 | Number of segments in a message | — | X | — |
006200430 | Message reference number | — | X | — |
Conditions of this table
The free text of the 14 conditions referenced by the rows above. All conditions of the message type are listed in the condition index ORDERS.
| Marker | Condition |
|---|---|
| [61] | MP-ID only from division electricity |
| [147] | if the code EM is present in DE3155 in the same COM |
| [148] | if the code TE / FX / AJ / AL is present in DE3155 in the same COM |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that. |
| [518] | Note: For subscription start and subscription end respectively, the specified execution date determines from when or until when (inclusive) the subscription is to run. |
| [521] | Note: Use of the ID of the market location |
| [567] | Note: Only one piece of information may be transmitted in DE3148 |
| [903] | Format: Possible value: 1 |
| [931] | Format: ZZZ = +00 |
| [939] | Format: the character string must contain the characters @ and . |
| [940] | Format: the character string must begin with the character + and may only be followed by digits |
| [950] | Format: market location ID |
| [UB1] | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
Example message
UNA:+.? '
UNB+UNOC:3+9903111000003:500+9904629000006:500+{{date}}:{{time}}+LZX9TCGL'
UNH+M06DSCB1+ORDERS:D:09B:UN:1.4b'
BGM+Z29+M0S9VUBM'
DTM+137:202408150600?+00:303'
DTM+203:202503282300?+00:303'
IMD++Z02'
RFF+Z13:17006'
NAD+MS+9903111000003::293'
CTA+IC+:Laue'
COM+mako@enercity.de:EM'
NAD+MR+9904629000006::293'
NAD+DP'
LOC+172+55123678945'
LIN+1'
IMD++Z61'
UNS+S'
UNT+16+M06DSCB1'
UNZ+1+LZX9TCGL'[1 item
{6 fields
"data": {3 fields
"stammdaten": {2 fields
"ANFRAGE": [1 item
{6 fields
"AUFTRAG": [1 item
{4 fields
"positionsdaten": [1 item
{2 fields
"transaktionsdaten": {8 fields
"absender": {6 fields
"ansprechpartner": {4 fields
"empfaenger": {4 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF and MSB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | Termination of invoicing for metering point operation via the LF by the LF | WiM electricity part 1 | Electricity | Step 1 |
| LF | LF | Termination of invoicing for metering point operation via the LF by the MSB | WiM electricity part 1 | Electricity | Step 1 |
| MSB | MSB-MALO | Termination of invoicing for metering point operation via the LF by the LF | WiM electricity part 1 | Electricity | Step 1 |
| MSB | MSB-MALO | Termination of invoicing for metering point operation via the LF by the MSB | WiM electricity part 1 | Electricity | Step 1 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Termination of invoice processing MSB via LF |
| AHB | ORDERS AHB |
| Transmission channel | AS4 |
This check identifier is used in 2 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| WiM electricity part 1 | Termination of invoice processing for metering point operation via the LF by the MSB | MSB (corresponds to MSB on the object market location) → LF | Termination of invoice processing for metering point operation via the LF |
| WiM electricity part 1 | Termination of invoice processing for metering point operation via the LF by the LF | LF → MSB (corresponds to MSB on the market location object) | Termination of invoice processing for metering point operation via the LF |
Transaction and responses
Role of this check identifier: request. Basis: the transaction data carry neither antwortstatus nor antwortstatusCodeliste, and neither the title nor the action of the Prüfi table begins with “response” or “response message”.
Which messages respond to this
| Role | Check identifier | Use case | Message type | Origin of supply |
|---|---|---|---|---|
| Response | 19009 | Confirmation of termination of invoice processing MSB | ORDRSP | from the step sequence |
| Response | 19010 | Rejection termination of invoice processing MSB | ORDRSP | from the step sequence |
This column is the inverse of the assignment on the response pages — not the next step of a list. The process source says of its own steps that they are »possible messages, not a sequence«.
Check identifiers of the same AHB table: No other check identifier of message type ORDERS has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 59 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains one transaction for this check identifier under the message type orders. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.