Check identifier 21033 — Rejection of the request
Check identifier 21033 · EDIFACT message type IFTSTA · Format version 202604
Data structure
| Structure (BO4E) | Description | Format | 21033 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| MARKTLOKATION [ ] | — | object[] | May | — |
| marktlokationsId 00010 | Identification number of a market location at which energy is either consumed or generated | string | X | — |
| MESSLOKATION [ ] | — | object[] | May | — |
| messlokationsId 00020 | The metering location identification. This is the former metering point identifier, e.g. DE 47108151234567 | string | X | — |
| NETZLOKATION [ ] | — | object[] | May | — |
| netzlokationsId 00030 | Identification number of a grid location at which energy is either consumed or generated (like MarktlokationsId market location) | string | X | — |
| STATUSMITTEILUNG [ ] * | — | object[] | Must | — |
| auftragsstatus * 00040 | Order status | Enum Auftragsstatus | X | — |
GESCHEITERT | — | — | X | — |
ERFOLGREICH | — | — | X | — |
LIEFERUNG_GEPLANT | — | — | X | — |
GEPLANT | — | — | X | — |
ZUGESTIMMT | — | — | X | — |
WIDERSPROCHEN | — | — | X | — |
STOERUNGSFREI | — | — | X | — |
GESTOERT | — | — | X | — |
FESTGESTELLTE_STOERUNG | — | — | X | — |
VERMUTETE_STOERUNG | — | — | X | — |
ABGELEHNT | — | — | X | — |
BEENDET | — | — | X | — |
ANTWORT_DRITTER | — | — | X | — |
BESTAETIGT | — | — | X | — |
UMGESETZT | — | — | X | — |
ENFG_STROMSPEICHER_UND_VERLUSTENERGIE | — | — | X | — |
ENFG_ELEKTRISCH_ANGETRIEBENE_WAERMEPUMPEN | — | — | X | — |
ENFG_UMLAGEERHEBUNG_BEI_ANLAGEN_ZUR_VERSTROMUNG_VON_KUPPELGASEN | — | — | X | — |
ENFG_HERSTELLUNG_VON_GRUENEN_WASSERSTOFF | — | — | X | — |
ENFG_STROMKOSTENINTENSIVE_UNTERNEHMEN | — | — | X | — |
ENFG_HERSTELLUNG_VON_WASSERSTOFF_IN_STROMKOSTENINTENSIVEN_UNTERNEHMEN | — | — | X | — |
ENFG_SCHIENENBAHNEN | — | — | X | — |
ENFG_ELEKTRISCHE_BETRIEBENE_BUSSEN_IM_LINIENVERKEHR | — | — | X | — |
ENFG_LANDSTROMANLAGEN | — | — | X | — |
AENDERUNG_DER_DATEN | — | — | X | — |
KEINE_AENDERUNG_DER_DATEN | — | — | X | — |
ZEITREIHE_AKZEPTIERT | — | — | X | — |
ZEITREIHE_NICHT_AKZEPTIERT | — | — | X | — |
| positionsdaten [ ] * | — | object[] | Must | — |
| positionsnummer * 00050 | positionsnummer | integer | Must | — |
| allgemeineInformationen | — | object | May | — |
| info1 00060 | General info 1 | string | X | — |
| info2 00070 | General info 2 | string | X | — |
| info3 00080 | General info 3 | string | X | — |
| info4 00090 | General info 4 | string | X | — |
| info5 00100 | General info 5 | string | X | — |
| STEUERBARE_RESSOURCE [ ] | — | object[] | May | — |
| ressourcenId 00110 | ressourcenId | string | X | — |
| transaktionsdaten * | — | object | Must | — |
| anfragereferenznummer * 00120 | Reference transaction number 'from request message' / ORDERS RFF+TN / IFTSTA RFF+AAV / INSRPT RFF+TN RFF+AAV | string | X | — |
| antwortstatus * 00130 | Response status / STS+E01 | string | X | — |
| antwortstatusCodeliste * 00140 | Response status code list / STS+E01 | string | X | — |
| dokumentennummer * 00150 | EDIFACT reference from the BGM segment / BGM | string | X | — |
| nachrichtendatum * 00160 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenreferenznummer * 00170 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 00180 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| sendungsposition 00190 | Consignment item / GID | string | Must | — |
| startdatum 00200 | Start date or point in time, earliest / DTM+469 | string (date-time) | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 00210 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00220 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| ansprechpartner | — | object | May | — |
| eMailAdresse 00230 | Email address | string | Must | — |
| nachname 00240 | Surname (family name) of the contact person | string | X | — |
| rufnummern [ ] | — | object[] | May | — |
| nummerntyp 00250 | Phone number type | Enum Rufnummernart | Must | — |
RUF_ZENTRALE | — | — | Must | — |
FAX_ZENTRALE | — | — | Must | — |
SAMMELRUF | — | — | Must | — |
SAMMELFAX | — | — | Must | — |
ABTEILUNGRUF | — | — | Must | — |
ABTEILUNGFAX | — | — | Must | — |
RUF_DURCHWAHL | — | — | Must | — |
FAX_DURCHWAHL | — | — | Must | — |
MOBIL_NUMMER | — | — | Must | — |
| rufnummer 00260 | rufnummer | string | Must | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 00270 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00280 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 21033 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 IFTSTA00020 | Multimodal status report | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 18A00040 | Edition 2018 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 2.0g00060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 Z0900070 | WiM message(s) | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/ message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| SG1.NAD | — | — | Must | — |
3035 MR00120 | Message recipient | — | X | — |
303900130 | MP-ID | — | X | [27] |
3055 900140 | GS1 | — | X | — |
3055 29300150 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG1.NAD | — | — | Must | — |
3035 MS00160 | Document-/ message sender or sender | — | X | — |
303900170 | MP-ID | — | X | [27] |
3055 900180 | GS1 | — | X | — |
3055 29300190 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG2.CTA | — | — | Must | — |
3139 IC00200 | Information contact | — | X | — |
341200210 | Contact | — | X | — |
| SG2.COM | — | — | Must | — |
314800220 | Number / email address | — | X | (([939][146]) ∨ ([940][147])) ∧ [534] |
3155 EM00230 | — | X | [1P0..1] | |
3155 FX00240 | Fax number | — | X | [1P0..1] |
3155 TE00250 | Telephone | — | X | [1P0..1] |
3155 AJ00260 | further telephone | — | X | [1P0..1] |
3155 AL00270 | Mobile phone | — | X | [1P0..1] |
| SG14.CNI | — | — | Must | — |
149000280 | Transaction number | — | X | [911] |
| SG14.LOC | — | — | Must | [149] ∧ [150] |
3227 17200290 | Reporting point | — | X | — |
322500300 | Identifier | — | X | ([950] [506]) ⊻ ([951][505]) ⊻ ([960][532]) ⊻ ([961][533]) |
| SG15.STS | — | — | Must | — |
9015 Z2000310 | Status of the referenced document | — | X | — |
4405 Z3200320 | rejected | — | X | — |
901300330 | Code of the check step | — | X | — |
1131 E_020700340 | EBD no. E_0207 | — | X | [20] |
1131 E_025200350 | EBD no. E_0252 | — | X | [76] |
1131 E_052400360 | EBD no. E_0524 | — | X | [26] |
1131 E_053100370 | EBD no. E_0531 | — | X | [20] |
1131 E_027800380 | EBD no. E_0278 | — | X | [26] |
1131 E_028100390 | EBD no. E_0281 | — | X | [20] |
| SG15.RFF | — | — | Must | — |
1153 Z1300400 | Check identifier | — | X | — |
1154 2103300410 | WiM, GPKE / request rejection (MSB to ESA / LF / NB) | — | X | — |
| SG15.RFF | — | — | Must | — |
1153 AAV00420 | Number of the request | — | X | — |
115400430 | Document-/transaction number of the reference message | — | X | [502] |
| SG15.DTM | — | — | Must | [30] |
2005 46900440 | Start date or point in time, earliest | — | X | — |
238000450 | Date or time or time span, value | — | X | [UB1] |
2379 30300460 | CCYYMMDDHHMMZZZ | — | X | — |
| SG25.GID | — | — | Must | — |
149600470 | Consignment item | — | X | — |
| SG25.FTX | — | — | Must | — |
4451 ACB00480 | Additional information (for general notes) | — | X | — |
444000490 | Free text | — | X | — |
| UNT | — | — | Must | — |
007400500 | Number of segments in a message | — | X | — |
006200510 | Message reference number | — | X | — |
Conditions of this table
The free text of the 26 conditions referenced by the rows above. All conditions of the message type are listed in the condition index IFTSTA.
| Marker | Condition |
|---|---|
| [20] | If MP-ID in SG1 NAD+MR in the role LF |
| [26] | If MP-ID in SG1 NAD+MR in the role NB |
| [27] | Only MP-ID from the electricity division |
| [30] | If STS+Z20+Z32+A07:E_0207 is present in this SG15. |
| [76] | If MP-ID in SG1 NAD+MR in the role ESA |
| [146] | If code EM is present in DE3155 in the same COM |
| [147] | If code TE / FX / AJ / AL is present in DE3155 in the same COM |
| [149] | If STS DE1131 <> E_0278 in this SG14 |
| [150] | If STS DE1131 <> E_0281 in this SG14 |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [502] | Note: From REQOTE BGM DE1004 |
| [505] | Note: Use of the ID of the metering location |
| [506] | Note: Use of the ID of the market location |
| [532] | Note: Use of the ID of the grid location |
| [533] | Note: Use of the ID of the controllable resource |
| [534] | Note: Only one piece of information may be transmitted in DE3148 |
| [911] | Format: Possible values: 1 to n, starting at 1 for each message and ascending consecutively |
| [931] | Format: ZZZ = +00 |
| [939] | Format: the character string must contain the characters @ and . |
| [940] | Format: the character string must begin with the character + and may only be followed by digits |
| [950] | Format: market location ID |
| [951] | Format: Metering point identifier |
| [960] | Format: Grid location ID |
| [961] | Format: SR-ID |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
| [UB1] | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |
Example message
UNA:+.? '
UNB+UNOC:3+9904733000009:500+9900244000009:500+{{date}}:{{time}}+M0KXRR1W'
UNH+M11I1RWQ+IFTSTA:D:18A:UN:2.0g'
BGM+Z09+M0YOR4X5'
DTM+137:202510170636?+00:303'
NAD+MR+9900244000009::293'
NAD+MS+9904733000009::293'
CTA+IC+:Laue'
COM+lieferantenwechsel@eon-energie.com:EM'
CNI+1'
LOC+172+44152365487'
STS+Z20+Z32+A01:E_0524'
RFF+Z13:21033'
RFF+AAV:7584'
UNT+13+M11I1RWQ'
UNZ+1+M0KXRR1W'[1 item
{6 fields
"data": {3 fields
"stammdaten": {2 fields
"MARKTLOKATION": [1 item
{5 fields
"marktlokationsTyp": [1 item
{1 field
"STATUSMITTEILUNG": [1 item
{5 fields
"positionsdaten": [1 item
{1 field
"transaktionsdaten": {12 fields
"absender": {6 fields
"ansprechpartner": {4 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF, NB, MSB and ESA.
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Rejection of the request |
| AHB | IFTSTA AHB |
| Decision tree | E_0524 · E_0531 · E_0207 · E_0252 · E_0278 · E_0281 |
| Transmission channel | AS4 |
This check identifier is used in 6 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| GPKE part 3 | Order placement for a configuration from NB to MSB | MSB → NB | Quotation for/ rejection of the request |
| GPKE part 3 | Order placement for a configuration from LF to MSB | MSB → LF | Quotation for / rejection of the request |
| WiM electricity part 1 | Request for invoice processing of metering point operation via the LF by the LF | MSB (corresponds to MSB on the object market location) → LF | Quotation /rejection of request |
| WiM electricity part 2 | Request and order placement of values by the ESA | MSB → ESA | Quotation for / rejection of the request |
| AWH processes for changing the technology at locations | Metering location change from NB to MSB | MSB (corresponds to MSB on the object metering location) → NB | Quotation or rejection of the request |
| AWH processes for changing the technology at locations | Metering location change from LF to MSB | MSB (corresponds to MSB on the object metering location) → LF | Quotation or rejection of the request |
One entry from format version 202610
The check identifiers table of format version 202604 does not carry this entry: decision tree. It comes from version 202610. Everything else on this page — use case, rulebook and communication direction — comes from its own version. Before adopting this into an implementation specification, check whether what is stated applies to 202604.
Transaction and responses
Role of this check identifier: response — rejection. Basis: the transaction data carry antwortstatus and antwortstatusCodeliste; the title names a polarity (rejection).
Which request this message responds to
| Role | Check identifier | Use case | Message type | Origin of supply |
|---|---|---|---|---|
| Request | 35002 | Request for invoice processing MSB via LF | REQOTE | from the step sequence |
| Request | 35004 | Request for a configuration | REQOTE | from the step sequence |
In which field the request is quoted
| Reference field of this message | EDIFACT segment | Target field in the request |
|---|---|---|
anfragereferenznummer | SG14.CNI.SG15.STS+Z20.RFF+AAV | dokumentennummer |
RFF+AAV quotes the preceding message via its BGM; the target is the dokumentennummer of the request. Measured: 35002, 35004 carry dokumentennummer in BGM+Z29, BGM+[Z74|Z82].
Response codes
Decision trees: E_0207 · E_0252 · E_0524 · E_0531 · E_0278 · E_0281.
The handbook names 6 decision trees for this check identifier. Their result codes are not given here but on the page of each tree — together they would run to several hundred rows, and the information would be lost among them.
Check identifiers of the same AHB table: No other check identifier of message type IFTSTA has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 67 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains one transaction for this check identifier under the message type iftsta. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.