Check identifier 21005 — Status message
Check identifier 21005 · EDIFACT message type IFTSTA · Format version 202604
This page is derived from the application handbook
The MACO APP does not carry this check identifier. The complete Prüfi pages of this level are produced from the specifications of the application — one class in the templater per check identifier — and that is where the assignment to the business objects (BO4E) comes from: which object carries which field of the message.
The catalogue of the application handbook is the larger set. This page therefore shows what the handbook itself provides — use case, process context and the AHB field list with its conditions. A data structure according to BO4E is not shown, and not because there is none, but because the application does not form one for this check identifier.
All check identifiers in this situation — and the corresponding figures — are listed by the overview of this version.
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 21005 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 IFTSTA00020 | Multimodal status report | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 18A00040 | Edition 2018 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 2.0g00060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 Z0300070 | MaBiS message(s) | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/ message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| SG1.NAD | — | — | Must | — |
3035 MR00120 | Message recipient | — | X | — |
303900130 | MP-ID | — | X | [27] |
3055 900140 | GS1 | — | X | — |
3055 29300150 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG1.NAD | — | — | Must | — |
3035 MS00160 | Document-/ message sender or sender | — | X | — |
303900170 | MP-ID | — | X | [27] |
3055 900180 | GS1 | — | X | — |
3055 29300190 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG2.CTA | — | — | Must | — |
3139 IC00200 | Information contact | — | X | — |
341200210 | Contact | — | X | — |
| SG2.COM | — | — | Must | — |
314800220 | Number / email address | — | X | (([939] [146]) ∨ ([940][147])) ∧ [534] |
3155 EM00230 | — | X | [1P0..1] | |
3155 FX00240 | Fax number | — | X | [1P0..1] |
3155 TE00250 | Telephone | — | X | [1P0..1] |
3155 AJ00260 | further telephone | — | X | [1P0..1] |
3155 AL00270 | Mobile phone | — | X | [1P0..1] |
| SG4.EQD | — | — | Must | — |
8053 Z0100280 | Sequential number | — | X | — |
826000290 | Transaction number | — | X | [911] |
| SG4.RFF | — | — | Must | — |
1153 Z1300300 | Check identifier | — | X | — |
1154 2100500310 | MaBiS / status message from the BKV/NB to BIKO | — | X | — |
| SG4.RFF | — | — | Must | — |
1153 AUU00320 | Reference to a time series | — | X | — |
115400330 | Version of the aggregated time series | — | X | — |
| SG6.LOC | — | — | Must | — |
3227 17200340 | Reporting point | — | X | — |
322500350 | Identifier | — | X | [951] [504] |
| SG6.DTM | — | — | Must | — |
2005 49200360 | Balancing date, - time, -period | — | X | — |
238000370 | Date or time or time span, value | — | X | — |
2379 61000380 | CCYYMM | — | X | — |
| SG6.DTM | — | — | Must | — |
2005 33400390 | Status change, date/time | — | X | — |
238000400 | Date or time or time span, value | — | X | [931] [495] |
2379 30400410 | CCYYMMDDHHMMSSZZZ | — | X | — |
| SG7.STS | — | — | Must | — |
9015 Z0200420 | Refusal of the aggregated time series | — | X | — |
901300430 | Code of the check step | — | X | [51] |
1131 E_006200440 | EBD no. E_0062 | — | X | — |
1131 E_006300450 | EBD no. E_0063 | — | X | — |
1131 E_006400460 | EBD no. E_0064 | — | X | — |
1131 E_006500470 | EBD no. E_0065 | — | X | — |
1131 E_009800480 | EBD no. E_0098 | — | X | — |
1131 E_009900490 | EBD no. E_0099 | — | X | — |
| SG7.STS | — | — | Must | — |
9015 Z0300500 | Check status for the aggregated time series | — | X | — |
4405 Z0700510 | Time series accepted | — | X | — |
4405 Z0800520 | Time series not accepted | — | X | — |
901300530 | Code of the check step | — | X | [45] ∨ [46] |
1131 E_006200540 | EBD no. E_0062 | — | X | — |
1131 E_006300550 | EBD no. E_0063 | — | X | — |
1131 E_006400560 | EBD no. E_0064 | — | X | — |
1131 E_006500570 | EBD no. E_0065 | — | X | — |
1131 E_009800580 | EBD no. E_0098 | — | X | — |
1131 E_009900590 | EBD no. E_0099 | — | X | — |
| UNT | — | — | Must | — |
007400600 | Number of segments in a message | — | X | — |
006200610 | Message reference number | — | X | — |
Conditions of this table
The free text of the 16 conditions referenced by the rows above. All conditions of the message type are listed in the condition index IFTSTA.
| Marker | Condition |
|---|---|
| [27] | Only MP-ID from the electricity division |
| [45] | If STS+Z03+Z07 present, only codes from the EBD cluster "consent" are possible. |
| [46] | If STS+Z03+Z08 present, only codes from the EBD cluster "rejection" are possible. |
| [51] | Only codes from the EBD cluster "refusal" are possible. |
| [146] | If code EM is present in DE3155 in the same COM |
| [147] | If code TE / FX / AJ / AL is present in DE3155 in the same COM |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [495] | The point in time must be ≤ the value in DE2380 of DTM+137 |
| [504] | Note: Use of the ID of the MaBiS-ZP |
| [534] | Note: Only one piece of information may be transmitted in DE3148 |
| [911] | Format: Possible values: 1 to n, starting at 1 for each message and ascending consecutively |
| [931] | Format: ZZZ = +00 |
| [939] | Format: the character string must contain the characters @ and . |
| [940] | Format: the character string must begin with the character + and may only be followed by digits |
| [951] | Format: Metering point identifier |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are NB, ÜNB, BIKO and BKV.
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Status message |
| AHB | IFTSTA AHB |
| Decision tree | E_0062 · E_0063 · E_0064 · E_0065 · E_0098 · E_0099 |
| Transmission channel | AS4 |
This check identifier is used in 6 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| MaBiS | Transmission of the validation notification for the balancing area aggregate time series to ÜNB | NB → BIKO | Validation notification BG-SZR (category B) |
| MaBiS | Transmission of the validation notification for the balancing group aggregated time series from the BKV to BIKO and NB | BKV → BIKO | Validation notification BK-SZR (category A) |
| MaBiS | Transmission of the validation notification for the balancing group aggregated time series from the BKV to BIKO and ÜNB | BKV → BIKO | Validation notification BK-SZR (category B) |
| MaBiS | Transmission of the validation notification for the delta time series transfer from NB via BIKO to ÜNB | NB → BIKO | Validation notification DZÜ |
| MaBiS | Transmission of the validation notification for the monthly curtailed energy transfer time series (AAÜZ) | BKV (of the LF) → BIKO | Validation notification monthly AAÜZ |
| MaBiS | Transmission of the validation notification for the curtailed energy transfer time series between the BKV (anfNB) and NB | BKV (of the anfNB) → BIKO | Validation notification monthly AAÜZ |
One entry from format version 202610
The check identifiers table of format version 202604 does not carry this entry: decision tree. It comes from version 202610. Everything else on this page — use case, rulebook and communication direction — comes from its own version. Before adopting this into an implementation specification, check whether what is stated applies to 202604.
Notes on this page
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 77 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.