Check identifier 21026 — Status message
Check identifier 21026 · EDIFACT message type IFTSTA · Format version 202604
Data structure
| Structure (BO4E) | Description | Format | 21026 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| MESSLOKATION [ ] * | — | object[] | Must | — |
| messlokationsId * 00010 | The metering location identification. This is the former metering point identifier, e.g. DE 47108151234567 | string | X | — |
| STATUSMITTEILUNG [ ] * | — | object[] | Must | — |
| auftragsstatus * 00020 | Order status | Enum Auftragsstatus | X | — |
GESCHEITERT | — | — | X | — |
ERFOLGREICH | — | — | X | — |
LIEFERUNG_GEPLANT | — | — | X | — |
GEPLANT | — | — | X | — |
ZUGESTIMMT | — | — | X | — |
WIDERSPROCHEN | — | — | X | — |
STOERUNGSFREI | — | — | X | — |
GESTOERT | — | — | X | — |
FESTGESTELLTE_STOERUNG | — | — | X | — |
VERMUTETE_STOERUNG | — | — | X | — |
ABGELEHNT | — | — | X | — |
BEENDET | — | — | X | — |
ANTWORT_DRITTER | — | — | X | — |
BESTAETIGT | — | — | X | — |
UMGESETZT | — | — | X | — |
ENFG_STROMSPEICHER_UND_VERLUSTENERGIE | — | — | X | — |
ENFG_ELEKTRISCH_ANGETRIEBENE_WAERMEPUMPEN | — | — | X | — |
ENFG_UMLAGEERHEBUNG_BEI_ANLAGEN_ZUR_VERSTROMUNG_VON_KUPPELGASEN | — | — | X | — |
ENFG_HERSTELLUNG_VON_GRUENEN_WASSERSTOFF | — | — | X | — |
ENFG_STROMKOSTENINTENSIVE_UNTERNEHMEN | — | — | X | — |
ENFG_HERSTELLUNG_VON_WASSERSTOFF_IN_STROMKOSTENINTENSIVEN_UNTERNEHMEN | — | — | X | — |
ENFG_SCHIENENBAHNEN | — | — | X | — |
ENFG_ELEKTRISCHE_BETRIEBENE_BUSSEN_IM_LINIENVERKEHR | — | — | X | — |
ENFG_LANDSTROMANLAGEN | — | — | X | — |
AENDERUNG_DER_DATEN | — | — | X | — |
KEINE_AENDERUNG_DER_DATEN | — | — | X | — |
ZEITREIHE_AKZEPTIERT | — | — | X | — |
ZEITREIHE_NICHT_AKZEPTIERT | — | — | X | — |
| statusObjekt * 00030 | Status object | Enum Statusobjekt | X | — |
MSBWECHSEL | — | — | X | — |
UMBAUMELO | — | — | X | — |
ERSTEINBAUIMS | — | — | X | — |
ERSTEINBAUMME | — | — | X | — |
GERAET | — | — | X | — |
ANGEBOTANFRAGE | — | — | X | — |
STATUSBESTELLUNG | — | — | X | — |
LIEFERSCHEIN | — | — | X | — |
SPERREN | — | — | X | — |
ENTSPERREN | — | — | X | — |
PRIVILEGIERUNG_NACH_ENFG | — | — | X | — |
VERAENDERUNGSSTATUS_DER_DATEN | — | — | X | — |
TURNUSAUSLESUNG | — | — | X | — |
PRUEFSTATUS_ANTWORT_SUMMENZEITREIHEN | — | — | X | — |
ABWEISUNG_SUMMENZEITREIHE | — | — | X | — |
PRUEFSTATUS_SUMMENZEITREIHE | — | — | X | — |
DATENSTATUS_SUMMENZEITREIHE | — | — | X | — |
ABWEISUNG_STATUSMELDUNG_AENDERUNG | — | — | X | — |
AUSFALLARBEIT | — | — | X | — |
FAHRPLANANTEIL | — | — | X | — |
GEGENVORSCHLAG_AUSFALLARBEIT | — | — | X | — |
GEGENVORSCHLAG_FAHRPLANANTEIL | — | — | X | — |
| positionsdaten [ ] * | — | object[] | Must | — |
| positionsnummer * 00040 | positionsnummer | integer | Must | — |
| transaktionsdaten * | — | object | Must | — |
| dokumentennummer * 00050 | EDIFACT reference from the BGM segment / BGM | string | X | — |
| fertigstellungsdatum * 00060 | Completion date / DTM+293 | string (date-time) | X | — |
| nachrichtendatum * 00070 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenreferenznummer * 00080 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 00090 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 00100 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00110 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| ansprechpartner | — | object | May | — |
| eMailAdresse 00120 | Email address | string | Must | — |
| nachname 00130 | Surname (family name) of the contact person | string | X | — |
| rufnummern [ ] | — | object[] | May | — |
| nummerntyp 00140 | Phone number type | Enum Rufnummernart | Must | — |
RUF_ZENTRALE | — | — | Must | — |
FAX_ZENTRALE | — | — | Must | — |
SAMMELRUF | — | — | Must | — |
SAMMELFAX | — | — | Must | — |
ABTEILUNGRUF | — | — | Must | — |
ABTEILUNGFAX | — | — | Must | — |
RUF_DURCHWAHL | — | — | Must | — |
FAX_DURCHWAHL | — | — | Must | — |
MOBIL_NUMMER | — | — | Must | — |
| rufnummer 00150 | rufnummer | string | Must | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 00160 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00170 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 21026 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 IFTSTA00020 | Multimodal status report | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 18A00040 | Edition 2018 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 2.0g00060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 Z0900070 | WiM message(s) | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document/message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZ ZZ | — | X | — |
| SG1.NAD | — | — | Must | — |
3035 MR00120 | Message recipient | — | X | — |
303900130 | MP-ID | — | X | [28] |
3055 900140 | GS1 | — | X | — |
3055 33200150 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG1.NAD | — | — | Must | — |
3035 MS00160 | Document-/ message sender or sender | — | X | — |
303900170 | MP-ID | — | X | [28] |
3055 900180 | GS1 | — | X | — |
3055 33200190 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG2.CTA | — | — | Must | — |
3139 IC00200 | Information contact | — | X | — |
341200210 | Contact | — | X | — |
| SG2.COM | — | — | Must | — |
314800220 | Number / email address | — | X | (([939] [146]) ∨ ([940] [147])) ∧ [534] |
3155 EM00230 | — | X | [1P0..1] | |
3155 FX00240 | Fax number | — | X | [1P0..1] |
3155 TE00250 | Telephone | — | X | [1P0..1] |
3155 AJ00260 | further telephone | — | X | [1P0..1] |
3155 AL00270 | Mobile phone | — | X | [1P0..1] |
| SG14.CNI | — | — | Must | — |
149000280 | Transaction number | — | X | [911] |
| SG14.LOC | — | — | Must | — |
3227 17200290 | Reporting point | — | X | — |
322500300 | Identifier | — | X | [951] [505] |
| SG15.STS | — | — | Must | — |
9015 Z1500310 | Metering point modification | — | X | — |
4405 Z1400320 | successful | — | X | — |
| SG15.RFF | — | — | Must | — |
1153 Z1300330 | Check identifier | — | X | — |
1154 2102600340 | WiM / status message (successful) from the MSB to the NB | — | X | — |
| SG15.DTM | — | — | Must | — |
2005 29300350 | Completion date/time | — | X | — |
238000360 | Date or time or time span, value | — | X | [931] [495] |
2379 30300370 | CCYYMMDDHHMMZ ZZ | — | X | — |
| UNT | — | — | Must | — |
007400380 | Number of segments in a message | — | X | — |
006200390 | Message reference number | — | X | — |
Conditions of this table
The free text of the 13 conditions referenced by the rows above. All conditions of the message type are listed in the condition index IFTSTA.
| Marker | Condition |
|---|---|
| [28] | Only MP-ID from the gas division |
| [146] | If code EM is present in DE3155 in the same COM |
| [147] | If code TE / FX / AJ / AL is present in DE3155 in the same COM |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [495] | The point in time must be ≤ the value in DE2380 of DTM+137 |
| [505] | Note: Use of the ID of the metering location |
| [534] | Note: Only one piece of information may be transmitted in DE3148 |
| [911] | Format: Possible values: 1 to n, starting at 1 for each message and ascending consecutively |
| [931] | Format: ZZZ = +00 |
| [939] | Format: the character string must contain the characters @ and . |
| [940] | Format: the character string must begin with the character + and may only be followed by digits |
| [951] | Format: Metering point identifier |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
Example message
UNA:+.? '
UNB+UNOC:3+4045399000015:502+4045399000015:502+{{date}}:{{time}}+M0SA3FYV'
UNH+M0HB9WGZ+IFTSTA:D:18A:UN:2.0g'
BGM+Z09+M09609D8'
DTM+137:202408200953?+00:303'
NAD+MR+4045399000015::332'
NAD+MS+4045399000015::332'
CTA+IC+:Andre'
COM+andre.l@conuti.de:EM'
CNI+1'
LOC+172+DE00014545768S0000000000000003054'
STS+Z15+Z14'
RFF+Z13:21026'
DTM+293:202312241830?+00:303'
UNT+13+M0HB9WGZ'
UNZ+1+M0SA3FYV'[1 item
{6 fields
"data": {3 fields
"stammdaten": {2 fields
"MESSLOKATION": [1 item
{4 fields
"STATUSMITTEILUNG": [1 item
{5 fields
"positionsdaten": [1 item
{1 field
"transaktionsdaten": {10 fields
"absender": {6 fields
"ansprechpartner": {4 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
There is no role view for this check identifier: in this format version no process step of any market role carries it. A role statement would stand here without evidence.
No process in this release
The entry in which this check identifier appears is not a process but a chapter reference: as parties involved, the source names only running text there (“parties involved as in the original message”), and the step has neither a number nor an action. Counted as a process, it would have reported a coverage gap that is none — it still cannot be rendered. This is a gap in the process source, not in the delivery — and it is the reason why no “Belongs to these role views” table appears here.
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Status message |
| AHB | IFTSTA AHB |
| Transmission channel | AS4 |
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| WiM gas | Ch. C 1.2 No. 6c | MSB → NB | Execution notification |
Transaction and responses
Role of this check identifier: request. Basis: the transaction data carry neither antwortstatus nor antwortstatusCodeliste, and neither the title nor the action of the Prüfi table begins with “response” or “response message”.
Responses: No response of this format version names this check identifier as a reference — neither explicitly in the Prüfi table nor via the step sequence. That does not mean there is none; it means that the sources do not record one.
Check identifiers of the same AHB table: No other check identifier of message type IFTSTA has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 52 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains one transaction for this check identifier under the message type iftsta. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.