Check identifier 21027 — Status message
Check identifier 21027 · EDIFACT message type IFTSTA · Format version 202604
Data structure
| Structure (BO4E) | Description | Format | 21027 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| MARKTLOKATION [ ] | — | object[] | May | — |
| marktlokationsId 00010 | Identification number of a market location at which energy is either consumed or generated | string | X | — |
| MESSLOKATION [ ] | — | object[] | May | — |
| messlokationsId 00020 | The metering location identification. This is the former metering point identifier, e.g. DE 47108151234567 | string | X | — |
| NETZLOKATION [ ] | — | object[] | May | — |
| netzlokationsId 00030 | Identification number of a grid location at which energy is either consumed or generated (like MarktlokationsId market location) | string | X | — |
| STATUSMITTEILUNG [ ] * | — | object[] | Must | — |
| auftragsstatus * 00040 | Order status | Enum Auftragsstatus | X | — |
GESCHEITERT | — | — | X | — |
ERFOLGREICH | — | — | X | — |
LIEFERUNG_GEPLANT | — | — | X | — |
GEPLANT | — | — | X | — |
ZUGESTIMMT | — | — | X | — |
WIDERSPROCHEN | — | — | X | — |
STOERUNGSFREI | — | — | X | — |
GESTOERT | — | — | X | — |
FESTGESTELLTE_STOERUNG | — | — | X | — |
VERMUTETE_STOERUNG | — | — | X | — |
ABGELEHNT | — | — | X | — |
BEENDET | — | — | X | — |
ANTWORT_DRITTER | — | — | X | — |
BESTAETIGT | — | — | X | — |
UMGESETZT | — | — | X | — |
ENFG_STROMSPEICHER_UND_VERLUSTENERGIE | — | — | X | — |
ENFG_ELEKTRISCH_ANGETRIEBENE_WAERMEPUMPEN | — | — | X | — |
ENFG_UMLAGEERHEBUNG_BEI_ANLAGEN_ZUR_VERSTROMUNG_VON_KUPPELGASEN | — | — | X | — |
ENFG_HERSTELLUNG_VON_GRUENEN_WASSERSTOFF | — | — | X | — |
ENFG_STROMKOSTENINTENSIVE_UNTERNEHMEN | — | — | X | — |
ENFG_HERSTELLUNG_VON_WASSERSTOFF_IN_STROMKOSTENINTENSIVEN_UNTERNEHMEN | — | — | X | — |
ENFG_SCHIENENBAHNEN | — | — | X | — |
ENFG_ELEKTRISCHE_BETRIEBENE_BUSSEN_IM_LINIENVERKEHR | — | — | X | — |
ENFG_LANDSTROMANLAGEN | — | — | X | — |
AENDERUNG_DER_DATEN | — | — | X | — |
KEINE_AENDERUNG_DER_DATEN | — | — | X | — |
ZEITREIHE_AKZEPTIERT | — | — | X | — |
ZEITREIHE_NICHT_AKZEPTIERT | — | — | X | — |
| positionsdaten [ ] * | — | object[] | Must | — |
| positionsnummer * 00050 | positionsnummer | integer | Must | — |
| allgemeineInformationen | — | object | May | — |
| info1 00060 | General info 1 | string | X | — |
| info2 00070 | General info 2 | string | X | — |
| info3 00080 | General info 3 | string | X | — |
| info4 00090 | General info 4 | string | X | — |
| info5 00100 | General info 5 | string | X | — |
| STEUERBARE_RESSOURCE [ ] | — | object[] | May | — |
| ressourcenId 00110 | ressourcenId | string | X | — |
| transaktionsdaten * | — | object | Must | — |
| antwortstatus * 00120 | Response status / STS+E01 | string | X | — |
| antwortstatusCodeliste 00130 | Response status code list / STS+E01 | string | X | — |
| dokumentennummer * 00140 | EDIFACT reference from the BGM segment / BGM | string | X | — |
| nachrichtendatum * 00150 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenreferenznummer * 00160 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 00170 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| sendungsposition 00180 | Consignment item / GID | string | Must | — |
| absender * | — | object | Must | — |
| rollencodenummer * 00190 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00200 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| ansprechpartner | — | object | May | — |
| eMailAdresse 00210 | Email address | string | Must | — |
| nachname 00220 | Surname (family name) of the contact person | string | X | — |
| rufnummern [ ] | — | object[] | May | — |
| nummerntyp 00230 | Phone number type | Enum Rufnummernart | Must | — |
RUF_ZENTRALE | — | — | Must | — |
FAX_ZENTRALE | — | — | Must | — |
SAMMELRUF | — | — | Must | — |
SAMMELFAX | — | — | Must | — |
ABTEILUNGRUF | — | — | Must | — |
ABTEILUNGFAX | — | — | Must | — |
RUF_DURCHWAHL | — | — | Must | — |
FAX_DURCHWAHL | — | — | Must | — |
MOBIL_NUMMER | — | — | Must | — |
| rufnummer 00240 | rufnummer | string | Must | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 00250 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00260 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 21027 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 IFTSTA00020 | Multimodal status report | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 18A00040 | Edition 2018 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 2.0g00060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 Z0900070 | WiM message(s) | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document/message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZ ZZ | — | X | — |
| SG1.NAD | — | — | Must | — |
3035 MR00120 | Message recipient | — | X | — |
303900130 | MP-ID | — | X | — |
3055 900140 | GS1 | — | X | — |
3055 29300150 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
3055 33200160 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG1.NAD | — | — | Must | — |
3035 MS00170 | Document-/ message sender or sender | — | X | — |
303900180 | MP-ID | — | X | — |
3055 900190 | GS1 | — | X | — |
3055 29300200 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
3055 33200210 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG2.CTA | — | — | Must | — |
3139 IC00220 | Information contact | — | X | — |
341200230 | Contact | — | X | — |
| SG2.COM | — | — | Must | — |
314800240 | Number / email address | — | X | (([939] [146]) ∨ ([940] [147])) ∧ [534] |
3155 EM00250 | — | X | [1P0..1] | |
3155 FX00260 | Fax number | — | X | [1P0..1] |
3155 TE00270 | Telephone | — | X | [1P0..1] |
3155 AJ00280 | further telephone | — | X | [1P0..1] |
3155 AL00290 | Mobile phone | — | X | [1P0..1] |
| SG14.CNI | — | — | Must | — |
149000300 | Transaction number | — | X | [911] |
| SG14.LOC | — | — | Must | — |
3227 17200310 | Reporting point | — | X | — |
322500320 | Identifier | — | X | (([951] [505]) ⊻ ([960][532]) ⊻ ([961] [533])) |
| SG15.STS | — | — | Must | — |
9015 Z1500330 | Metering point modification | — | X | — |
4405 Z1300340 | failed | — | X | — |
901300350 | Code of the check step | — | X | [26] ∧ [153] |
9013 Z7400360 | no access | — | X | [103] ∧ [537] |
9013 Z7500370 | Communication fault | — | X | [103] ∧ [537] |
1131 E_028600380 | EBD no. E_0286 | — | X | — |
| SG15.RFF | — | — | Must | — |
1153 Z1300390 | Check identifier | — | X | — |
1154 2102700400 | WiM / status message (failed) from the MSB to NB / MSB | — | X | — |
| SG25.GID | — | — | Must | — |
149600410 | Consignment item | — | X | [903] |
| SG25.FTX | — | — | Must | — |
4451 ACB00420 | Additional information (for general notes) | — | X | — |
444000430 | Free text | — | X | — |
| UNT | — | — | Must | — |
007400440 | Number of segments in a message | — | X | — |
006200450 | Message reference number | — | X | — |
Conditions of this table
The free text of the 20 conditions referenced by the rows above. All conditions of the message type are listed in the condition index IFTSTA.
| Marker | Condition |
|---|---|
| [26] | If MP-ID in SG1 NAD+MR in the role NB |
| [103] | If in this STS DE1131 is not present |
| [146] | If code EM is present in DE3155 in the same COM |
| [147] | If code TE / FX / AJ / AL is present in DE3155 in the same COM |
| [153] | If DE1131 = E_0286 in this STS |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [505] | Note: Use of the ID of the metering location |
| [532] | Note: Use of the ID of the grid location |
| [533] | Note: Use of the ID of the controllable resource |
| [534] | Note: Only one piece of information may be transmitted in DE3148 |
| [537] | Note: The code is necessary because this use case also applies in all use cases in which the information to be transmitted in this segment does not result from a decision tree. |
| [903] | Format: Possible value: 1 |
| [911] | Format: Possible values: 1 to n, starting at 1 for each message and ascending consecutively |
| [931] | Format: ZZZ = +00 |
| [939] | Format: the character string must contain the characters @ and . |
| [940] | Format: the character string must begin with the character + and may only be followed by digits |
| [951] | Format: Metering point identifier |
| [960] | Format: Grid location ID |
| [961] | Format: SR-ID |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
Example message
Example 1
UNA:+.? '
UNB+UNOC:3+9904733000009:500+9905257000004:500+{{date}}:{{time}}+UNHM2J7WJW9'
UNH+UNHM2J7WJW9+IFTSTA:D:18A:UN:2.0g'
BGM+Z09+BGMM2XCRGA7'
DTM+137:202510041200?+00:303'
NAD+MR+9905257000004::293'
NAD+MS+9904733000009::293'
CNI+1'
LOC+172+DE00014545768S0000000000000003054'
STS+Z15+Z13+A99:E_0286'
RFF+Z13:21027'
GID+1'
FTX+ACB+++Hier steht der Text, der erklärt,:warum abgelehnt wurde.:Und hier der weitere Text.:Und hier der weitere Text:Und hier der weitere Text.'
UNT+12+UNHM2J7WJW9'
UNZ+1+UNHM2J7WJW9'[1 item
{6 fields
"data": {3 fields
"stammdaten": {2 fields
"MESSLOKATION": [1 item
{4 fields
"STATUSMITTEILUNG": [1 item
{5 fields
"positionsdaten": [1 item
{2 fields
"allgemeineInformationen": {5 fields
"transaktionsdaten": {12 fields
"absender": {4 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Example 2
UNA:+.? '
UNB+UNOC:3+9903790000002:500+9900244000009:500+{{date}}:{{time}}+M2PHD2DV'
UNH+UNHM2J7WJW9+IFTSTA:D:18A:UN:2.0g'
BGM+Z09+BGMM2XCRGA7'
DTM+137:202510041200?+00:303'
NAD+MR+9900244000009::293'
NAD+MS+9903790000002::293'
CNI+1'
LOC+172+E1688110000'
STS+Z15+Z13+Z74'
RFF+Z13:21027'
UNT+10+UNHM2J7WJW9'
UNZ+1+M2PHD2DV'[1 item
{6 fields
"data": {3 fields
"stammdaten": {2 fields
"NETZLOKATION": [1 item
{4 fields
"STATUSMITTEILUNG": [1 item
{5 fields
"positionsdaten": [1 item
{1 field
"transaktionsdaten": {10 fields
"absender": {4 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Example 3
UNA:+.? '
UNB+UNOC:3+9903790000002:500+9900244000009:500+{{date}}:{{time}}+M2PHD2DV'
UNH+UNHM2J7WJW9+IFTSTA:D:18A:UN:2.0g'
BGM+Z09+BGMM2XCRGA7'
DTM+137:202510041200?+00:303'
NAD+MR+9900244000009::293'
NAD+MS+9903790000002::293'
CNI+1'
LOC+172+C816417ST77'
STS+Z15+Z13+Z75'
RFF+Z13:21027'
UNT+10+UNHM2J7WJW9'
UNZ+1+M2PHD2DV'[1 item
{6 fields
"data": {3 fields
"stammdaten": {2 fields
"STEUERBARE_RESSOURCE": [1 item
{4 fields
"STATUSMITTEILUNG": [1 item
{5 fields
"positionsdaten": [1 item
{1 field
"transaktionsdaten": {10 fields
"absender": {4 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF, NB and MSB.
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Status message |
| AHB | IFTSTA AHB |
| Decision tree | E_0286 |
| Transmission channel | AS4 |
This check identifier is used in 5 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| WiM gas | Ch. C 1.2 No. 7c | MSB → NB | Failure of the change |
| WiM electricity part 1 | Metering location change from NB to MSB | MSB (corresponds to MSB on the object metering location) → NB | Failure of the change |
| WiM electricity part 1 | Initial installation of a iMS in an existing metering location | MSB (corresponds to wMSB on the object metering location) → MSB (corresponds to gMSB on the object metering location) | Information on failure of the device replacement |
| WiM electricity part 1 | Initial installation of a iMS in an existing metering location | MSB (corresponds to gMSB on the object metering location) → NB | Information on no device replacement to iMS |
| AWH processes for changing the technology at locations | Metering location change from NB to MSB | MSB (corresponds to MSB on the object metering location) → NB | Failure of the change |
One entry from format version 202610
The check identifiers table of format version 202604 does not carry this entry: decision tree. It comes from version 202610. Everything else on this page — use case, rulebook and communication direction — comes from its own version. Before adopting this into an implementation specification, check whether what is stated applies to 202604.
Transaction and responses
Role of this check identifier: status message. This IFTSTA message carries a status field (antwortstatus and antwortstatusCodeliste), but its title names neither “response” nor a polarity. It is therefore recorded as a status message and not as a response in the sense of a decision tree.
Forwarding (triangular communication): The preceding step holds 21029 with the same send direction. This message therefore does not answer the sender of the preceding step, it forwards — which is why there is no response sentence here.
Reference field: This message carries none of the fields with which a response cites its request (anfragereferenznummer, auftragsReferenz, vorgangsreferenznummer, anfrageReferenz). The reference is therefore not in the data of this message: which message is meant follows only from the process, not from the message itself.
Response codes
Decision tree E_0286 — named in: AHB STS DE1131 and Prüfi table.
| Response code | Cluster | Meaning | Outputs |
|---|---|---|---|
| A01 | — | Failed The technician has no access to the location. | 1 |
| A02 | — | Failed The change of the technology at the location is not possible because of a missing / faulty communication connection. | 1 |
| A03 | — | Failed The ordered assignment of the stated TR to the SR/NeLo cannot be implemented because of the situation on site. | 1 |
| A99 | — | Failed Other Note: The identified problem must be described/named in the response. End of usability: 01.10.2026 00:00 | 1 |
Check identifiers of the same AHB table: No other check identifier of message type IFTSTA has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 59 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains 3 transactions for this check identifier under the message type iftsta. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.