Check identifier 21002 — Refusal
Check identifier 21002 · EDIFACT message type IFTSTA · Format version 202610
This page is derived from the application handbook
The MACO APP does not carry this check identifier. The complete Prüfi pages of this level are produced from the specifications of the application — one class in the templater per check identifier — and that is where the assignment to the business objects (BO4E) comes from: which object carries which field of the message.
The catalogue of the application handbook is the larger set. This page therefore shows what the handbook itself provides — use case, process context and the AHB field list with its conditions. A data structure according to BO4E is not shown, and not because there is none, but because the application does not form one for this check identifier.
All check identifiers in this situation — and the corresponding figures — are listed by the overview of this version.
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 21002 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 IFTSTA00020 | Multimodal status report | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 18A00040 | Edition 2018 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 2.100060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 Z0300070 | MaBiS message(s) | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| SG1.NAD | — | — | Must | — |
3035 MR00120 | Message recipient | — | X | — |
303900130 | MP-ID | — | X | [27] |
3055 900140 | GS1 | — | X | — |
3055 29300150 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG1.NAD | — | — | Must | — |
3035 MS00160 | Document-/message sender or sender | — | X | — |
303900170 | MP-ID | — | X | [27] |
3055 900180 | GS1 | — | X | — |
3055 29300190 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG4.EQD | — | — | Must | — |
8053 Z0100200 | Sequential number | — | X | — |
826000210 | Transaction number | — | X | [911] |
| SG4.RFF | — | — | Must | — |
1153 Z1300220 | Check identifier | — | X | — |
1154 2100200230 | MaBiS / refusal from the BIKO to NB/ÜNB | — | X | — |
| SG4.RFF | — | — | Must | — |
1153 AUU00240 | Reference to a time series | — | X | — |
115400250 | Version of the aggregated time series | — | X | — |
| SG6.LOC | — | — | Must | — |
3227 17200260 | Reporting point | — | X | — |
322500270 | Identifier | — | X | [951] [504] |
| SG6.DTM | — | — | Must | — |
2005 49200280 | Balancing date, -time, -period | — | X | — |
238000290 | Date or time or time span, value | — | X | — |
2379 61000300 | CCYYMM | — | X | — |
| SG6.DTM | — | — | Must | — |
2005 33400310 | Status change, date/time | — | X | — |
238000320 | Date or time or time span, value | — | X | [931] [495] |
2379 30400330 | CCYYMMDDHHMMSSZZZ | — | X | — |
| SG7.STS | — | — | Must | — |
9015 Z0200340 | Refusal of the aggregated time series | — | X | — |
901300350 | Code of the check step | — | X | — |
1131 E_000800360 | EBD no. E_0008 | — | X | — |
1131 E_002300370 | EBD no. E_0023 | — | X | — |
1131 E_002900380 | EBD no. E_0029 | — | X | — |
1131 E_003600390 | EBD no. E_0036 | — | X | — |
1131 E_003800400 | EBD no. E_0038 | — | X | — |
1131 E_007300410 | EBD no. E_0073 | — | X | — |
1131 E_008000420 | EBD no. E_0080 | — | X | — |
| UNT | — | — | Must | — |
007400430 | Number of segments in a message | — | X | — |
006200440 | Message reference number | — | X | — |
Conditions of this table
The free text of the 7 conditions referenced by the rows above. All conditions of the message type are listed in the condition index IFTSTA.
| Marker | Condition |
|---|---|
| [27] | Only MP-ID from the electricity division |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [495] | The point in time must be ≤ the value in DE2380 of DTM+137 |
| [504] | Note: Use of the ID of the MaBiS-ZP |
| [911] | Format: Possible values: 1 to n, starting at 1 for each message and ascending consecutively |
| [931] | Format: ZZZ = +00 |
| [951] | Format: Metering point identifier |
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are NB, ÜNB, BIKO and BKV.
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Refusal |
| AHB | IFTSTA AHB |
| Decision tree | E_0008 · E_0036 · E_0038 · E_0023 · E_0029 · E_0073 · E_0080 |
| Transmission channel | AS4 |
This check identifier is used in 8 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| MaBiS | Transmission of the grid time series | BIKO → NB | Response |
| MaBiS | Transmission of the balancing area aggregate time series from the ÜNB | BIKO → ÜNB | Response |
| MaBiS | Transmission of the balancing group aggregated time series from the NB to BIKO and BKV | BIKO → NB | Response |
| MaBiS | Transmission of the balancing group aggregated time series from the ÜNB to BIKO and BKV | BIKO → ÜNB | Response |
| MaBiS | Transmission of the delta time series transfer from the ÜNB to BIKO and NB | BIKO → ÜNB | Response |
| MaBiS | Transmission of the monthly curtailed energy transfer time series (AAÜZ) | BIKO → NB | Response |
| MaBiS | Transmission of the monthly curtailed energy transfer time series between ANB and BKV (anfNB) | BIKO → NB (ANB) | Response |
| MaBiS | UF MaBiS_005 transmission of the balancing area aggregate time series from the ÜNB | BIKO → ÜNB | Response |
Further relationships from format version 202604
Version 202604 also carries this check identifier in contexts that the table of version 202610 does not know; they are included in the list above. Everything else on this page — use case, rulebook and communication direction — comes from the page's own version. Before adopting it into an implementation specification, check whether what is stated applies to 202610.
Notes on this page
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 57 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.