Check identifier 21039 — Order status (disconnect)
Check identifier 21039 · EDIFACT message type IFTSTA · Format version 202604
Data structure
| Structure (BO4E) | Description | Format | 21039 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| MARKTLOKATION [ ] * | — | object[] | Must | — |
| marktlokationsId * 00010 | Identification number of a market location at which energy is either consumed or generated | string | X | — |
| STATUSMITTEILUNG [ ] * | — | object[] | Must | — |
| auftragsstatus 00020 | Order status | Enum Auftragsstatus | X | — |
GESCHEITERT | — | — | X | — |
ERFOLGREICH | — | — | X | — |
LIEFERUNG_GEPLANT | — | — | X | — |
GEPLANT | — | — | X | — |
ZUGESTIMMT | — | — | X | — |
WIDERSPROCHEN | — | — | X | — |
STOERUNGSFREI | — | — | X | — |
GESTOERT | — | — | X | — |
FESTGESTELLTE_STOERUNG | — | — | X | — |
VERMUTETE_STOERUNG | — | — | X | — |
ABGELEHNT | — | — | X | — |
BEENDET | — | — | X | — |
ANTWORT_DRITTER | — | — | X | — |
BESTAETIGT | — | — | X | — |
UMGESETZT | — | — | X | — |
ENFG_STROMSPEICHER_UND_VERLUSTENERGIE | — | — | X | — |
ENFG_ELEKTRISCH_ANGETRIEBENE_WAERMEPUMPEN | — | — | X | — |
ENFG_UMLAGEERHEBUNG_BEI_ANLAGEN_ZUR_VERSTROMUNG_VON_KUPPELGASEN | — | — | X | — |
ENFG_HERSTELLUNG_VON_GRUENEN_WASSERSTOFF | — | — | X | — |
ENFG_STROMKOSTENINTENSIVE_UNTERNEHMEN | — | — | X | — |
ENFG_HERSTELLUNG_VON_WASSERSTOFF_IN_STROMKOSTENINTENSIVEN_UNTERNEHMEN | — | — | X | — |
ENFG_SCHIENENBAHNEN | — | — | X | — |
ENFG_ELEKTRISCHE_BETRIEBENE_BUSSEN_IM_LINIENVERKEHR | — | — | X | — |
ENFG_LANDSTROMANLAGEN | — | — | X | — |
AENDERUNG_DER_DATEN | — | — | X | — |
KEINE_AENDERUNG_DER_DATEN | — | — | X | — |
ZEITREIHE_AKZEPTIERT | — | — | X | — |
ZEITREIHE_NICHT_AKZEPTIERT | — | — | X | — |
| statusObjekt 00030 | Status object | Enum Statusobjekt | X | — |
MSBWECHSEL | — | — | X | — |
UMBAUMELO | — | — | X | — |
ERSTEINBAUIMS | — | — | X | — |
ERSTEINBAUMME | — | — | X | — |
GERAET | — | — | X | — |
ANGEBOTANFRAGE | — | — | X | — |
STATUSBESTELLUNG | — | — | X | — |
LIEFERSCHEIN | — | — | X | — |
SPERREN | — | — | X | — |
ENTSPERREN | — | — | X | — |
PRIVILEGIERUNG_NACH_ENFG | — | — | X | — |
VERAENDERUNGSSTATUS_DER_DATEN | — | — | X | — |
TURNUSAUSLESUNG | — | — | X | — |
PRUEFSTATUS_ANTWORT_SUMMENZEITREIHEN | — | — | X | — |
ABWEISUNG_SUMMENZEITREIHE | — | — | X | — |
PRUEFSTATUS_SUMMENZEITREIHE | — | — | X | — |
DATENSTATUS_SUMMENZEITREIHE | — | — | X | — |
ABWEISUNG_STATUSMELDUNG_AENDERUNG | — | — | X | — |
AUSFALLARBEIT | — | — | X | — |
FAHRPLANANTEIL | — | — | X | — |
GEGENVORSCHLAG_AUSFALLARBEIT | — | — | X | — |
GEGENVORSCHLAG_FAHRPLANANTEIL | — | — | X | — |
| positionsdaten [ ] * | — | object[] | Must | — |
| positionsnummer * 00040 | positionsnummer | integer | Must | — |
| allgemeineInformationen | — | object | May | — |
| info1 00050 | General info 1 | string | X | — |
| info2 00060 | General info 2 | string | X | — |
| info3 00070 | General info 3 | string | X | — |
| info4 00080 | General info 4 | string | X | — |
| info5 00090 | General info 5 | string | X | — |
| transaktionsdaten * | — | object | Must | — |
| antwortstatus 00100 | Response status / STS+E01 | string | X | — |
| antwortstatusCodeliste 00110 | Response status code list / STS+E01 | string | X | — |
| dokumentennummer * 00120 | EDIFACT reference from the BGM segment / BGM | string | X | — |
| fertigstellungsdatum 00130 | Completion date / DTM+293 | string (date-time) | X | — |
| nachrichtendatum * 00140 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenreferenznummer * 00150 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator 00160 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| sendungsposition 00170 | Consignment item / GID | string | Must | — |
| absender * | — | object | Must | — |
| rollencodenummer * 00180 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00190 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| ansprechpartner | — | object | May | — |
| eMailAdresse 00200 | Email address | string | Must | — |
| nachname 00210 | Surname (family name) of the contact person | string | X | — |
| rufnummern [ ] | — | object[] | May | — |
| nummerntyp 00220 | Phone number type | Enum Rufnummernart | Must | — |
RUF_ZENTRALE | — | — | Must | — |
FAX_ZENTRALE | — | — | Must | — |
SAMMELRUF | — | — | Must | — |
SAMMELFAX | — | — | Must | — |
ABTEILUNGRUF | — | — | Must | — |
ABTEILUNGFAX | — | — | Must | — |
RUF_DURCHWAHL | — | — | Must | — |
FAX_DURCHWAHL | — | — | Must | — |
MOBIL_NUMMER | — | — | Must | — |
| rufnummer 00230 | rufnummer | string | Must | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 00240 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00250 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 21039 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 IFTSTA00020 | Multimodal status report | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 18A00040 | Edition 2018 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 2.0g00060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 Z3300070 | GPKE message(s) | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/ message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| SG1.NAD | — | — | Must | — |
3035 MR00120 | Message recipient | — | X | — |
303900130 | MP-ID | — | X | — |
3055 900140 | GS1 | — | X | — |
3055 29300150 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
3055 33200160 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG1.NAD | — | — | Must | — |
3035 MS00170 | Document-/ message sender or sender | — | X | — |
303900180 | MP-ID | — | X | — |
3055 900190 | GS1 | — | X | — |
3055 29300200 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
3055 33200210 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG2.CTA | — | — | Must | — |
3139 IC00220 | Information contact | — | X | — |
341200230 | Contact | — | X | — |
| SG2.COM | — | — | Must | — |
314800240 | Number / email address | — | X | (([939][146]) ∨ ([940] [147])) ∧ [534] |
3155 EM00250 | — | X | [1P0..1] | |
3155 FX00260 | Fax number | — | X | [1P0..1] |
3155 TE00270 | Telephone | — | X | [1P0..1] |
3155 AJ00280 | further telephone | — | X | [1P0..1] |
3155 AL00290 | Mobile phone | — | X | [1P0..1] |
| SG14.CNI | — | — | Must | — |
149000300 | Transaction number | — | X | [911] |
| SG14.LOC | — | — | Must | — |
3227 17200310 | Reporting point | — | X | — |
322500320 | Identifier | — | X | [950] [506] |
| SG15.STS | — | — | Must | — |
9015 Z3700330 | Order status disconnect | — | X | — |
4405 Z1300340 | failed | — | X | ([91] ⊻ [133]) ∧ [20] |
4405 Z1400350 | successful | — | X | [91] ⊻ [133] |
4405 Z3200360 | rejected | — | X | [92] ⊻ [134] |
901300370 | Code of the check step | — | X | ([93] ⊻ [94] ⊻ [107]) |
1131 E_047200380 | EBD no. E_0472 | — | X | — |
1131 E_050100390 | EBD no. E_0501 | — | X | [20] |
1131 E_100200400 | EBD no. E_1002 | — | X | [20] |
1131 E_100300410 | EBD no. E_1003 | — | X | — |
| SG15.RFF | — | — | Must | — |
1153 Z1300420 | Check identifier | — | X | — |
1154 2103900430 | GPKE, Awh disconnection proc. Gas / Order status (disconnect) | — | X | — |
| SG15.DTM | — | — | Must | [77] |
2005 29300440 | Completion date/time | — | X | — |
238000450 | Date or time or time span, value | — | X | [931] [495] |
2379 30300460 | CCYYMMDDHHMMZZZ | — | X | — |
| SG25.GID | — | — | Must | — |
149600470 | Consignment item | — | X | [903] |
| SG25.FTX | — | — | Must | — |
4451 ACB00480 | Additional information (for general notes) | — | X | — |
444000490 | Free text | — | X | — |
| SG15.STS | — | — | Must | — |
9015 Z3800500 | Order status reconnect | — | X | — |
4405 Z1300510 | failed | — | X | [95] ⊻ [137] |
4405 Z1400520 | successful | — | X | [95] ⊻ [137] ⊻ [96] ⊻ [138] |
901300530 | Code of the check step | — | X | ((([97] ⊻ [98]) ∧ ([95] ⊻ [137])) ⊻ [99] ⊻ [139]) |
1131 E_048700540 | EBD no. E_0487 | — | X | — |
1131 E_049900550 | EBD no. E_0499 | — | X | — |
1131 E_100500560 | EBD no. E_1005 | — | X | — |
1131 E_102000570 | EBD no. E_1020 | — | X | — |
| SG15.RFF | — | — | Must | — |
1153 Z1300580 | Check identifier | — | X | — |
1154 2103900590 | GPKE, Awh disconnection proc. Gas / Order status (disconnect) | — | X | — |
| SG15.DTM | — | — | Must | [80] |
2005 29300600 | Completion date/time | — | X | — |
238000610 | Date or time or time span, value | — | X | [931] [495] |
2379 30300620 | CCYYMMDDHHMMZZZ | — | X | — |
| SG25.GID | — | — | Must | — |
149600630 | Consignment item | — | X | [903] |
| SG25.FTX | — | — | Must | — |
4451 ACB00640 | Additional information (for general notes) | — | X | — |
444000650 | Free text | — | X | — |
| UNT | — | — | Must | — |
007400660 | Number of segments in a message | — | X | — |
006200670 | Message reference number | — | X | — |
Conditions of this table
The free text of the 31 conditions referenced by the rows above. All conditions of the message type are listed in the condition index IFTSTA.
| Marker | Condition |
|---|---|
| [20] | If MP-ID in SG1 NAD+MR in the role LF |
| [77] | If STS+Z37+Z14 is present in this SG14 |
| [80] | If STS+Z38+Z14 is present in this SG14 |
| [91] | If DE1131 = E_0472 in this STS |
| [92] | If DE1131 = E_0501 in this STS |
| [93] | If STS+Z37+Z13 present, only codes from the EBD cluster "failed" are possible. |
| [94] | If STS+Z37+Z14 present, only codes from the EBD cluster "successful" are possible. |
| [95] | If DE1131 = E_0499 in this STS |
| [96] | If DE1131 = E_0487 in this STS |
| [97] | If STS+Z38+Z13 present, only codes from the EBD cluster "failed" are possible. |
| [98] | If STS+Z38+Z14 present, only codes from the EBD cluster "successful" are possible. |
| [99] | If DE1131 = E_0487 in this STS, only the code A01 is possible. |
| [107] | If STS+Z37+Z32 present, only codes from the EBD cluster "rejection" are possible. |
| [133] | If DE1131 = E_1003 in this STS |
| [134] | If DE1131 = E_1002 in this STS |
| [137] | If DE1131 = E_1005 in this STS |
| [138] | If DE1131 = E_1020 in this STS |
| [139] | If DE1131 = E_1020 in this STS, only the code A01 is possible. |
| [146] | If code EM is present in DE3155 in the same COM |
| [147] | If code TE / FX / AJ / AL is present in DE3155 in the same COM |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [495] | The point in time must be ≤ the value in DE2380 of DTM+137 |
| [506] | Note: Use of the ID of the market location |
| [534] | Note: Only one piece of information may be transmitted in DE3148 |
| [903] | Format: Possible value: 1 |
| [911] | Format: Possible values: 1 to n, starting at 1 for each message and ascending consecutively |
| [931] | Format: ZZZ = +00 |
| [939] | Format: the character string must contain the characters @ and . |
| [940] | Format: the character string must begin with the character + and may only be followed by digits |
| [950] | Format: market location ID |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
Example message
UNA:+.? '
UNB+UNOC:3+9900321000005:500+9903790000002:500+{{date}}:{{time}}+M0U0RBFQ'
UNH+UNHM05ZEKIV+IFTSTA:D:18A:UN:2.0g'
BGM+Z33+BGMM0DYSASC'
DTM+137:202504041200?+00:303'
NAD+MR+9903790000002::293'
NAD+MS+9900321000005::293'
CNI+1'
LOC+172+50074561188'
STS+Z37+Z13+A08:E_0472'
RFF+Z13:21039'
UNT+10+UNHM05ZEKIV'
UNZ+1+M0U0RBFQ'[1 item
{6 fields
"data": {3 fields
"stammdaten": {2 fields
"MARKTLOKATION": [1 item
{4 fields
"STATUSMITTEILUNG": [1 item
{5 fields
"positionsdaten": [1 item
{1 field
"transaktionsdaten": {11 fields
"absender": {4 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF, NB, MSB and ÜNB.
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Order status (disconnect) |
| AHB | IFTSTA AHB |
| Decision tree | E_1002 · E_1003 · E_1005 · E_1020 · E_0472 · E_0501 · E_0499 · E_0487 |
| Transmission channel | AS4 |
This check identifier is used in 18 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| AWH disconnection processes gas | Interruption of grid connection use (disconnect) on instruction of the LF | NB → LF | Result of the disconnection order |
| AWH disconnection processes gas | Interruption of grid connection use (disconnect) on instruction of the LF | NB → MSB | Result of the disconnection order |
| AWH disconnection processes gas | Restoration of grid connection use (reconnect) on instruction from the LF | NB → LF | Result of the reconnection order |
| AWH disconnection processes gas | Restoration of grid connection use (reconnect) on instruction from the LF | NB → MSB | Result of the reconnection order |
| AWH disconnection processes gas | Restoration of grid connection use at start of supply | NB → MSB | Result of the reconnection order |
| GPKE part 2 | Interruption of grid connection use (disconnect) on instruction of the LF | NB → LF | Result of the disconnection order |
| GPKE part 2 | Interruption of grid connection use (disconnect) on instruction of the LF | NB → MSB | Result of the disconnection order |
| GPKE part 2 | Interruption of grid connection use (disconnect) on instruction of the LF | NB → ÜNB | Result of the disconnection order |
| GPKE part 2 | Restoration of grid connection use (reconnect) on instruction from the LF | NB → LF | Result of the reconnection order |
| GPKE part 2 | Restoration of grid connection use (reconnect) on instruction from the LF | NB → MSB | Result of the reconnection order |
| GPKE part 2 | Restoration of grid connection use (reconnect) on instruction from the LF | NB → ÜNB | Result of the reconnection order |
| GPKE part 2 | Restoration of grid connection use at start of supply | NB → MSB | Result of the reconnection order |
| GPKE part 2 | Restoration of grid connection use at start of supply | NB → ÜNB | Result of the reconnection order |
| Application guide for gas disconnection processes | Interruption of grid connection use (disconnect) on instruction of the LF | NB → LF | Result of the disconnection order |
| Application guide for gas disconnection processes | Interruption of grid connection use (disconnect) on instruction of the LF | NB → MSB | Result of the disconnection order |
| Application guide for gas disconnection processes | Restoration of grid connection use (reconnect) on instruction from the LF | NB → LF | Result of the reconnection order |
| Application guide for gas disconnection processes | Restoration of grid connection use (reconnect) on instruction from the LF | NB → MSB | Result of the reconnection order |
| Application guide for gas disconnection processes | Restoration of grid connection use at start of supply | NB → MSB | Result of the reconnection order |
One entry from format version 202610
The check identifiers table of format version 202604 does not carry this entry: decision tree. It comes from version 202610. Everything else on this page — use case, rulebook and communication direction — comes from its own version. Before adopting this into an implementation specification, check whether what is stated applies to 202604.
Transaction and responses
Role of this check identifier: status message. This IFTSTA message carries a status field (antwortstatus and antwortstatusCodeliste), but its title names neither “response” nor a polarity. It is therefore recorded as a status message and not as a response in the sense of a decision tree.
Forwarding (triangular communication): The preceding step holds 21040 with the same send direction. This message therefore does not answer the sender of the preceding step, it forwards — which is why there is no response sentence here.
Reference field: This message carries none of the fields with which a response cites its request (anfragereferenznummer, auftragsReferenz, vorgangsreferenznummer, anfrageReferenz). The reference is therefore not in the data of this message: which message is meant follows only from the process, not from the message itself.
Response codes
Decision trees: E_0472 · E_0501 · E_1002 · E_1003 · E_0487 · E_0499 · E_1005 · E_1020.
The handbook names 8 decision trees for this check identifier. Their result codes are not given here but on the page of each tree — together they would run to several hundred rows, and the information would be lost among them.
Check identifiers of the same AHB table: No other check identifier of message type IFTSTA has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 87 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains one transaction for this check identifier under the message type iftsta. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.