Check identifier 21031 — Legacy prot. / self-installation iMS
Check identifier 21031 · EDIFACT message type IFTSTA · Format version 202604
Data structure
| Structure (BO4E) | Description | Format | 21031 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| MESSLOKATION [ ] * | — | object[] | Must | — |
| messlokationsId * 00010 | The metering location identification. This is the former metering point identifier, e.g. DE 47108151234567 | string | X | — |
| STATUSMITTEILUNG [ ] * | — | object[] | Must | — |
| auftragsstatus * 00020 | Order status | Enum Auftragsstatus | X | — |
GESCHEITERT | — | — | X | — |
ERFOLGREICH | — | — | X | — |
LIEFERUNG_GEPLANT | — | — | X | — |
GEPLANT | — | — | X | — |
ZUGESTIMMT | — | — | X | — |
WIDERSPROCHEN | — | — | X | — |
STOERUNGSFREI | — | — | X | — |
GESTOERT | — | — | X | — |
FESTGESTELLTE_STOERUNG | — | — | X | — |
VERMUTETE_STOERUNG | — | — | X | — |
ABGELEHNT | — | — | X | — |
BEENDET | — | — | X | — |
ANTWORT_DRITTER | — | — | X | — |
BESTAETIGT | — | — | X | — |
UMGESETZT | — | — | X | — |
ENFG_STROMSPEICHER_UND_VERLUSTENERGIE | — | — | X | — |
ENFG_ELEKTRISCH_ANGETRIEBENE_WAERMEPUMPEN | — | — | X | — |
ENFG_UMLAGEERHEBUNG_BEI_ANLAGEN_ZUR_VERSTROMUNG_VON_KUPPELGASEN | — | — | X | — |
ENFG_HERSTELLUNG_VON_GRUENEN_WASSERSTOFF | — | — | X | — |
ENFG_STROMKOSTENINTENSIVE_UNTERNEHMEN | — | — | X | — |
ENFG_HERSTELLUNG_VON_WASSERSTOFF_IN_STROMKOSTENINTENSIVEN_UNTERNEHMEN | — | — | X | — |
ENFG_SCHIENENBAHNEN | — | — | X | — |
ENFG_ELEKTRISCHE_BETRIEBENE_BUSSEN_IM_LINIENVERKEHR | — | — | X | — |
ENFG_LANDSTROMANLAGEN | — | — | X | — |
AENDERUNG_DER_DATEN | — | — | X | — |
KEINE_AENDERUNG_DER_DATEN | — | — | X | — |
ZEITREIHE_AKZEPTIERT | — | — | X | — |
ZEITREIHE_NICHT_AKZEPTIERT | — | — | X | — |
| positionsdaten [ ] * | — | object[] | Must | — |
| positionsnummer * 00030 | positionsnummer | integer | Must | — |
| transaktionsdaten * | — | object | Must | — |
| antwortstatus * 00040 | Response status / STS+E01 | string | X | — |
| antwortstatusCodeliste * 00050 | Response status code list / STS+E01 | string | X | — |
| dokumentennummer * 00060 | EDIFACT reference from the BGM segment / BGM | string | X | — |
| mitteilungsnummer * 00070 | Reference transaction number / RFF+ADY | string | X | — |
| nachrichtendatum * 00080 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenreferenznummer * 00090 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 00100 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| vorgangsreferenznummer * 00110 | Reference number of the transaction of the registration according to WiM / ORDERS RFF+Z41 / IFTSTA RFF+ACW | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 00120 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00130 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| ansprechpartner | — | object | May | — |
| eMailAdresse 00140 | Email address | string | Must | — |
| nachname 00150 | Surname (family name) of the contact person | string | X | — |
| rufnummern [ ] | — | object[] | May | — |
| nummerntyp 00160 | Phone number type | Enum Rufnummernart | Must | — |
RUF_ZENTRALE | — | — | Must | — |
FAX_ZENTRALE | — | — | Must | — |
SAMMELRUF | — | — | Must | — |
SAMMELFAX | — | — | Must | — |
ABTEILUNGRUF | — | — | Must | — |
ABTEILUNGFAX | — | — | Must | — |
RUF_DURCHWAHL | — | — | Must | — |
FAX_DURCHWAHL | — | — | Must | — |
MOBIL_NUMMER | — | — | Must | — |
| rufnummer 00170 | rufnummer | string | Must | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 00180 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00190 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 21031 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 IFTSTA00020 | Multimodal status report | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 18A00040 | Edition 2018 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 2.0g00060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 Z0900070 | WiM message(s) | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/ message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| SG1.NAD | — | — | Must | — |
3035 MR00120 | Message recipient | — | X | — |
303900130 | MP-ID | — | X | [27] |
3055 900140 | GS1 | — | X | — |
3055 29300150 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG1.NAD | — | — | Must | — |
3035 MS00160 | Document-/ message sender or sender | — | X | — |
303900170 | MP-ID | — | X | [27] |
3055 900180 | GS1 | — | X | — |
3055 29300190 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG2.CTA | — | — | Must | — |
3139 IC00200 | Information contact | — | X | — |
341200210 | Contact | — | X | — |
| SG2.COM | — | — | Must | — |
314800220 | Number / email address | — | X | (([939] [146]) ∨ ([940][147])) ∧ [534] |
3155 EM00230 | — | X | [1P0..1] | |
3155 FX00240 | Fax number | — | X | [1P0..1] |
3155 TE00250 | Telephone | — | X | [1P0..1] |
3155 AJ00260 | further telephone | — | X | [1P0..1] |
3155 AL00270 | Mobile phone | — | X | [1P0..1] |
| SG14.CNI | — | — | Must | — |
149000280 | Transaction number | — | X | [911] |
| SG14.LOC | — | — | Must | — |
3227 17200290 | Reporting point | — | X | — |
322500300 | Identifier | — | X | [951] [505] |
| SG15.STS | — | — | Must | — |
9015 Z1900310 | Initial installation iMS | — | X | — |
4405 Z3100320 | objected | — | X | — |
901300330 | Code of the check step | — | X | [47] |
1131 E_023300340 | EBD no. E_0233 | — | X | — |
| SG15.RFF | — | — | Must | — |
1153 Z1300350 | Check identifier | — | X | — |
1154 2103100360 | WiM / Grandfathering / self-installation iMS | — | X | — |
| SG15.RFF | — | — | Must | — |
1153 ACW00370 | Reference number of a preceding message | — | X | — |
115400380 | Reference, identification | — | X | — |
| SG15.RFF | — | — | Must | — |
1153 ADY00390 | Notification number | — | X | — |
115400400 | Reference, identification | — | X | — |
| UNT | — | — | Must | — |
007400410 | Number of segments in a message | — | X | — |
006200420 | Message reference number | — | X | — |
Conditions of this table
The free text of the 13 conditions referenced by the rows above. All conditions of the message type are listed in the condition index IFTSTA.
| Marker | Condition |
|---|---|
| [27] | Only MP-ID from the electricity division |
| [47] | Only codes from the EBD cluster "rejection" are possible. |
| [146] | If code EM is present in DE3155 in the same COM |
| [147] | If code TE / FX / AJ / AL is present in DE3155 in the same COM |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [505] | Note: Use of the ID of the metering location |
| [534] | Note: Only one piece of information may be transmitted in DE3148 |
| [911] | Format: Possible values: 1 to n, starting at 1 for each message and ascending consecutively |
| [931] | Format: ZZZ = +00 |
| [939] | Format: the character string must contain the characters @ and . |
| [940] | Format: the character string must begin with the character + and may only be followed by digits |
| [951] | Format: Metering point identifier |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
Example message
UNA:+.? '
UNB+UNOC:3+4045399000053:500+9978414000000:500+{{date}}:{{time}}+M0Y6TPIU'
UNH+M0GM3U32+IFTSTA:D:18A:UN:2.0g'
BGM+Z09+M0M2D1WI'
DTM+137:202506050625?+00:303'
NAD+MR+9978414000000::293'
NAD+MS+4045399000053::293'
CTA+IC+:lau'
COM+alaue@eon.de:EM'
CNI+1'
LOC+172+DE00014545768S0000000000000003054'
STS+Z19+Z31+A01:E_0233'
RFF+Z13:21031'
RFF+ACW:8904578942'
RFF+ADY:15'
UNT+14+M0GM3U32'
UNZ+1+M0Y6TPIU'[1 item
{6 fields
"data": {3 fields
"stammdaten": {2 fields
"MESSLOKATION": [1 item
{4 fields
"STATUSMITTEILUNG": [1 item
{5 fields
"positionsdaten": [1 item
{1 field
"transaktionsdaten": {13 fields
"absender": {6 fields
"ansprechpartner": {4 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF, NB and MSB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | Initial installation of a iMS in an existing metering location | WiM electricity part 1 | Electricity | Step 2 |
| NB | NB | Initial installation of a iMS in an existing metering location | WiM electricity part 1 | Electricity | Step 2 |
| MSB | GMSB | Initial installation of a iMS in an existing metering location | WiM electricity part 1 | Electricity | Step 2 |
| MSB | WMSB | Initial installation of a iMS in an existing metering location | WiM electricity part 1 | Electricity | Step 2 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Legacy prot. / self-installation iMS |
| AHB | IFTSTA AHB |
| Decision tree | E_0233 |
| Transmission channel | AS4 |
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| WiM electricity part 1 | Initial installation of a iMS in an existing metering location | MSB (corresponds to wMSB on the object metering location) → MSB (corresponds to gMSB on the object metering location) | Information on grandfathering / own installation iMS |
One entry from format version 202610
The check identifiers table of format version 202604 does not carry this entry: decision tree. It comes from version 202610. Everything else on this page — use case, rulebook and communication direction — comes from its own version. Before adopting this into an implementation specification, check whether what is stated applies to 202604.
Transaction and responses
Role of this check identifier: status message. This IFTSTA message carries a status field (antwortstatus and antwortstatusCodeliste), but its title names neither “response” nor a polarity. It is therefore recorded as a status message and not as a response in the sense of a decision tree.
Which request this message responds to
| Role | Check identifier | Use case | Message type | Origin of supply |
|---|---|---|---|---|
| Request | 21029 | Advance information | IFTSTA | from the step sequence |
In which field the request is quoted
| Reference field of this message | EDIFACT segment | Target field in the request |
|---|---|---|
vorgangsreferenznummer | SG14.CNI.SG15.STS+Z19.RFF+ACW | — |
RFF+ACW names the "preceding message". Which field is meant there is not carried by the source — the target remains open.
Response codes
Decision tree E_0233 — named in: AHB STS DE1131 and Prüfi table.
| Response code | Cluster | Meaning | Outputs |
|---|---|---|---|
| A01 | Rejection | Legacy protection under § 19 para. 5 MsbG for the metering location | 1 |
| A02 | Rejection | Self-installation of a iMS or a mME planned | 1 |
| A03 | Consent | Self-installation of iMS or mME is waived | 1 |
| A04 | Rejection | No statement possible regarding self-installation at this point in time | 1 |
Check identifiers of the same AHB table: No other check identifier of message type IFTSTA has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 56 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains one transaction for this check identifier under the message type iftsta. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.